You are on page 1of 8

MEB-2300K

EMG/EP Measuring System

Technical Data
DESIGN FEATURES EXAMINATION PROGRAMS
The Neuropack MEB-2300K EMG/EP Measuring ♦Standard Programs
System measures and averages EMG, electric/
auditory/visual evoked potential and nerve conduc- Somatosensory Evoked Potential Measurement
tion.* The MEB-2300K system software operates on • Somatosensory evoked potential (SEP) measure-
Microsoft® Windows. ment
• Short-latency somatosensory evoked potential
Newly designed 6 and 12 channel amplifiers (SSEP) measurement
The new amplifiers provide high quality waveforms. • ECG triggered SSEP (ECG-SSEP) measurement
• Evoked spinal cord potential (ESCP) measurement
Electrode junction box • Customizable somatosensory protocol (Electric)
2 types of electrode junction boxes can be selected.
JB-206B (6 channels) Auditory Evoked Potential Measurement
JB-212B (12 channels) • Auditory brainstem response (ABR) measurement
• Middle latency response (MLR) measurement
18 bit A/D conversion • Slow vertex response (SVR) measurement
18 bit A/D conversion provides high fidelity wave- • Electrocochleogram (EcochG) measurement
forms. • Customizable auditory protocol (Auditory)

Newly designed active electrode (option) Visual Evoked Potential Measurement


An active electrode reduces artifact noise from the • Pattern reversal - Visual evoked potential (Pattern-
electric stimulator. VEP) measurement
• Flash LED goggles - Visual evoked potential (LED-
Compact and easy to use electric stimulator, VEP) measurement
Somato control box, RY-230B (option) • External stimulator - Visual evoked potential (EXT-
The stimulator has dials to adjust the stimulation VEP) measurement
intensity and give electric stimulation. You can pre- • Electroretinogram (ERG) measurement
set several function. • Electrooculogram (EOG) measurement
• Customizable visual control (Visual)
Operation panel, PV-230B
Dedicated ergonomic design control panel for MEB- Electromyogram (EMG) Measurement
2300 enables you to operate machine easily. This
control panel has all the necessary buttons for EMG/ Quantitative EMG (QEMG) Measurement
EP examinations procedure.
Single Fiber EMG (SF EMG) and
Easy database management Macro EMG Measurement
NeuroWorkbench software makes it easier to man-
age examination schedules, edit measurement files Nerve Conduction Study
and archive the measurement files in the database. • Motor nerve conduction study (MCS)
• Sensory nerve conduction study (SCS)
NeuroReport • Nerve conduction studies (NCS)
The program has various item templates for reports. • Repetitive stimulation (REP. stim)
Reports are saved in a database and you can • F-wave measurement (F-wave)
quickly search for reports by patient information, • Monosynaptic reflex H-wave (H-reflex) measure-
measurement values and other criteria. After gener- ment
ating a report, you can export a report as a PDF file. • Collision method
• Polysynaptic reflex (orbicularis oculi muscle reflex)
Data saving in a built-in hard disk, CD-RW or measurement (Blink)
DVD-RW disk
Measured waveforms and data can be saved in
disks. Saved waveforms and data can be displayed
on the screen.

Data compatibility among Neuropack series


instruments
The MEB-2300 can read disk data from other
Neuropack series instrument - MEB-2200, MEB-
2300, MEB-9100, MEB-9200/9300 and MEB-9400.

2
♦ Optional Programs ♦ Acquisition
QP-258B Trend Monitoring Software A/D converter: 18 bits
• Intraoperative Monitoring (IOM) measurement Time base modes: Individually selected for each
channel (up to 12 channels)
QP-259B Autonomic Nervous System Test Monitor time base: 5, 10, 20, 30, 50 ms/div, 0.1, 0.2,
Software 0.5, 1 s/div (within ±5%)
• Microneurogram (MICRO-N) measurement Data points: 2048/20 div
• Sympathetic skin response (SSR) measurement Conversion speed: 5 µs/1 ch, 10 µs/2 ch, 20 µs/3 and
• R-R interval analysis 4 ch, 50 µs/5 to 10 ch, 100 µs/11 and 12 ch
Analysis time base: 0.1, 0.2, 0.5, 1, 2, 3, 5, 10, 20,
QP-260B Event Related Potential Software 30, 50 ms/div, 0.1, 0.2, 0.5, 1 s/div (within ±5%)
• P300 Or,
• Movement Related Cortical Potential (MRCP) 0.1 to 0.9 ms in 0.1 ms steps (within ±5%)
measurement 1 to 99 ms in 1.0 ms steps (within ±5%)
• Contingent Negative Variation (CNV) measurement 100 to 1000 ms in 0.01 s steps (within ±5%)
Delay time: −10 to 10 div in 1 div steps
Or,
0 to 500 ms in 0.1 ms steps
Number of averages: 1 to 9999
SPECIFICATIONS Artifact reject inhibit range: ±1 to ±5 div in 0.1 div
steps, Off
♦ Amplifiers Waveform storage capacity: Depends on the hard
disk free space of the PC unit
Number of channels: 6, 12
Number of breakout boxes: Up to 2
Input impedance: 200 MΩ ±20% (Differential mode), ♦ Display
200 MΩ ±20% (When the active electrode cable is Number of examination windows:
used, differential mode), ≥1000 MΩ(Common mode) Up to 12
Noise: < 0.6 µVrms at 1 Hz to 10 kHz, Waveform display mode: Monitor (free run), Sweep
< 1.1 µVrms at 1 Hz to 10 kHz (When the active (trigger), Average
electrode cable is used) Cursor: Two vertical or horizontal lines for time or
Common mode rejection ratio: ≥106 dB (Balanced amplitude measurements,
mode), One vertical line for mark set
≥90 dB (Balanced mode, when the active electrode Scale: 5, 10, 15, 20 div
cable is used), Grid: Line, dot, off
≥112 dB (Isolation mode)
Sensitivity: 1, 2, 5, 10, 20, 50, 100, 200, 500 µV/div,
1, 2, 5, 10 mV/div ±5% ♦ Stimulator Common Functions
Low-cut filter: 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, <Triggers>
10, 20, 30, 50, 100, 200, 500 Hz, 1, 2, 3 kHz (±20%) Number of channels: 6
High-cut filter: Channel 1 and 2: 10, 20, 50, 100, 200, Trigger mode: Recurrent, Random, Foot switch,
500 Hz, 1, 1.5, 2, 3, 5, 10, 20 kHz (±20%) Single stimulation, Signal 1 to 5, Somato 1, Somato 3,
Channel 3 to 5: Upper limit 10 kHz at −12 dB/oct External 1 to 6
(±20%) Trigger wave mode: Single, Double, Train
Channel 6 to 10: Upper limit 5 kHz at −12 dB/oct Stimulation rate:
(±20%) With the list box; 0.1 to 0.9 Hz in 0.1 Hz steps, 1 to 10
Channel 11 and 12: Upper limit 3 kHz at −12 dB/oct in 1 Hz step, 13, 15, 17 Hz, 20 to 100 Hz in 10 Hz
(±20%) steps (within ±5% of the preset value × 0.95)
AC interference notch filter: 50 or 60 Hz (Rejection With the keyboard; 0.1 to 100 Hz in 0.1 Hz steps
ratio: < 1/20) (within ±5%)
Reset: Available Delay time:
Rectification: Off, Half, Full With the list box; 0 to 9 ms in 1 ms steps, 10 to 90 ms
Skin-electrode contact impedance check: in 10 ms steps, 100 to 900 ms in 100 ms steps, 1 to
2, 5, 10, 20, 50 kΩ indication 10 s in 1 s step
Amplitude calibration: 1, 10, 100 µV, 1, 10 mV With the keyboard: 0 to 10 s in 0.01 ms steps
(within ±5%)

3
♦ Electric Stimulators ♦ Visual Stimulators
Number of channels: 2 (monophasic/biphasic stimu- Stimulation modes: Pattern reversal, LED goggles,
lation, high current stimulation) External visual stimulation
Output mode: Constant current Pattern reversal
Output current: Field format: Full, left, right, upper, lower, upper left,
Monophasic/biphasic stimulation; 0 to 100 mA (load lower left, upper right and lower right field
resistance: 1 kΩ, step can be selected from 0.05, 0.1, Patterns: Checkerboard, horizontal bars, vertical bars
0.2, 0.5, 1 mA) Number of horizontal divisions: 4, 8, 16, 32, 64, 128
High current stimulation; 0 to 200 mA (load resistance: Brightness: More than 80 cd/m2
1 kΩ, step can be selected from 0.05, 0.1, 0.2, 0.5, 1
mA) ♦ LED goggles
Range of load resistance: R =V/I (0 Ω ≤R ≤50 kΩ)
R: load resistance Side: Left, Right, Both
V: internal voltage (V=200: monophasic stimulation,
V=120: biphasic stimulation) ♦ Printer
I: stimulation intensity
Stimulation pulse duration: 1, 0.5, 0.3, 0.2, 0.1, 0.05, Printing mode: Hard copy, Review
0.03, 0.02, 0.01 ms
0.1 ms to 1 ms; within ±10% ♦ External Units
0.05 ms; within ±20%
0.03 ms or less or when stimulation intensity is set to 2 External input: 8 ch, 0.2, 1 V/div
mA or less; The stimulation pulse duration must not External output: 8 ch 1 V/div (5 kHz at 1 ch, 200 Hz
exceed the selected stimulation pulse duration setting. at 8 ch)
Number of outputs on the stimulation pod: 5 Line I/O: Available
Output current measurement function: Available Trigger input: 6 ch
Biphasic stimulation mode: Positive, negative, Amplitude: more than 4 V (positive) less than 0.5 V
bipolar, alternate (negative)
Temperature measurement: 0 to 45°C (32 to 113°F) Available for pulse whose duration is more than 10 µs
±0.1°C (0.18°F) Either positive and negative can be selectable
Trigger output: 6 ch
♦ Auditory Stimulators Amplitude: 5 V (positive) less than 0.5 V (negative)
Pulse duration: 1, 5, 10 ms, Either positive and
Examination side: Left, Both, Right negative can be selectable
Stimulation waveform: Click, Tone burst Response switch: When closed, operates at low level
Stimulation phase (polarity): Condensation (posi- Digital input: When closed, operates at low level, 6 ch
tive), Rarefaction (negative), Alternating Amplitude: less than 0.5 V (negative), Available for
Stimulation intensity: 0 to 135 dB SPL (within ±2 dB) pulse whose duration is more than 1 ms
Contralateral white noise masking:
0, −10, −20, −30, −40, −50 dB or off (within ±5 dB) ♦ Power Requirements
Click pulse duration: 0.1, 0.2, 0.3, 0.5, 1 ms (within
±5%) Line voltage and frequency (DC-230BK): 100 to 120
Tone burst frequency: V and 220 to 240 V ±10%, 50/60 Hz ±1%
With a list box; 125, 250, 500, 1 k, 1.5 k, 2 k, 3 k, 4 k, 6 When using the optional KD-030AJ cart or SC-
k, 8 kHz (within ±5%) 230B power unit: 100 to 120 V ±10%, 50/60 Hz ±1%
With a keyboard; 50 Hz to 10 kHz in 1Hz steps (within KD-030AK, SC-230BK: 220 to 240 V ±10%, 50/60 Hz
±5%) ±1%
Plateau time of tone burst: Power consumption SC-230B/SC-230BK power
With a list box; 0, 1, 2, 5, 10, 20, 50, 100, 200, 500, unit: 1250 VA
1000 ms (within ±5%) DC-230BK: 75 VA
With a keyboard; 0 to 1,000 ms in 1 ms steps (within
±5%) ♦ Environment
Rise/fall time of tone burst:
With a list box; 0.1, 0.2, 0.3, 0.5, 1, 2, 3, 10 ms (within Operating temperature: 10°c to 35°c (50 to 95°F)
±5%) Operating humidity: 30% to 80% (noncondensing)
With a keyboard; 0.1 to 3000 ms in 0.1 ms steps Operating atmospheric pressure: 70 to 106 kPa
(within ±5%) Storage temperature: −20°c to +65°c (−4 to +149°F)
Storage humidity: 10% to 95%
Storage atmospheric pressure: 70 to 106 kPa

4
♦ Safety
STANDARD ACCESSORIES
Safety standard:
IEC 60601-1: 1988-12 Qty
IEC 60601-1 Amendment 1: 1991-11 Somato A → B connection cable, YZ-0172 1
IEC 60601-1 Amendment 2: 1995-03 Protective earth cable, 098029 1
IEC 60601-1-1: 2000-12 USB cable, 584351 1
IEC 60601-2-40: 1998-02 Fuse (32 mA), 654998 1
IEC 60601-1-2: 2001-09 Foot switch, RY-482B 1
IEC 60601-1-2 Amendment 1: 2004 System program, QP-250BK 1
EN 60601-1: 1990, Amendment 1: 1993, Amend- Operator's manual, 0614-902246 1
ment 2: 1995 Examination guide, 0614-902255 1
EN 60601-1-1: 2001 Service manual, 0634-900433 1
EN 60601-1-2: 2001, Amendment 1: 2006 NeuroReport operator's manual, 0614-901158 1
EN 60601-2-40: 1998 Disk electrode for evoked potential, NE-132B 2
Type of protection against electric shock: Class I (5 electrodes/set)
Degree of protection against electric shock: Grounding electrode, NM-550B 1
Type BF applied parts: Electrode jacks and/or elec- Mouse pad, 6123-902759 1
trode lead jacks on the electrode junction box,
SOMATO, AUDITORY, GOGGLE, thermistor probe
Type B applied parts: Response switch
Degree of protection against harmful ingress of
water Protected against dripping water (IPX8):
Electrical switch in the foot switch
COMPOSITION
(1 meter under water for 24 hours)
Qty
Protected against dripping water (IPX1): Foot switch
Main unit, DC-230BK 1
unit
PC unit, desktop, CC-230BK 1
Non-protected (IPX0): Other parts
Control panel unit, PV-230B 1
Degree of safety of application in the presence of a
Constant current stimulator, MS-230BK 1
flammable anaesthetic mixture with air, oxygen or
Electrode junction box, 6ch, JB-206B 1
nitrous oxide:
Cart, KD-030AK 1
Not suitable for use in the presence of a flammable
LCD display, local purchase, (LCD Display) 1
anaesthetic mixture with air, oxygen or nitrous oxide
Laser printer, local purchase, (Laser Printer) 1
Mode of operation: Continuous operation
Arm, KH-231B 1
SOMATO control box, RY-230B 1
♦ Dimensions and Weight Active electrode cable, BM-230B 1
Power cord UL, YZ-001A1 1
Main unit: 390 (W) × 55 (H) × 304 (D) mm, 3.2 kg
Electrode junction box: 180 (W) × 56.5 (H) × 234.5
Note 1: KD-030AJ is replaced with KD-030AK for 100 -
(D) mm, 1.5 kg
127 V use.
Constant current stimulation unit: 56.5 (W) × 190
Note 2: YZ-001A1 is replaced with YZ-001A3 for 100 -
(H) × 240 (D) mm, 1.0 kg
127 V use.
Somato control box: 37 (W) × 62 (H) × 21 (D) mm,
Note 3: SC-230BK (for 220 - 240 V) or SC-230B (for 100
0.16 kg
- 127 V) is required for local purchase cart.
Control panel unit: 253 (W) × 36 (H) × 193 (D) mm,
1.0 kg
SC-230B/SC-230BK Power unit: 230 (W) × 100 (H) ×
300 (D) mm, 13.8 kg
Multi interface box: 160 (W) × 24 (H) × 120 (D) mm,
0.8 kg
KD-030A cart: 598 (W) × 1144 (H) × 853 (D) mm, 60.0
kg

♦ Electromagnetic Compatibility
IEC 60601-2-40: 1998
IEC 60601-1-2: 2001, Amendment 1: 2004
ANSI/AAMI/IEC 60601-1-2: 2001

5
H659 NM-451B, finger electrode, 0.3 m
OPTIONAL ACCESSORIES EMG electrode kit, H626
NCS Electrode
& CONSUMABLES H690 NM-317Y3, disposable, 2 recording electrode +
1 ground electrode × 10 pcs/set
H691 NM-319Y, disposable, 4 recording electrode ×
Multi Interface Box, JJ-230B
10 pcs/set
Breakout Box, JB-101B
H692 NM-316Y, disposable, 4 recording electrode + 1
Stimulation Pod (High), JS-101B
ground electrode × 10 pcs/set
LED goggles, LS-102J
H693 NM-310Y, disposable, 1 ground electrode × 10
Headphone, Y849A DR-531B14, adult
pcs/set
Headphone, Y849B DR-531B15, child
H694A NM-314YS, disposable, 4 MEP/SEP electrode
Earphone, YE-103J
× 10 pcs/set, 0.2 m lead
Note: Headphone or earphone is required for ABR.
H694B NM-314YL, disposable, 4 MEP/SEP electrode
Flash stimulator, SLS-3100
× 10 pcs/set, 1.8 m lead
Response Switch, 277825
K625A BM-001B, extension cable for H690/H691/
Electric Stimulator, SEN-4100J/K
H692/H693/H694A/H694B, 3 lead
Thermistor Temperature Probe, P242C 409J
K625B BM-002B, extension cable for H690/H691/
H692/H693/H694A/H694B, 2 lead
Hyper Isolation Transformer(HIT-100), QW-100Y
K629 BM-990W, extension cable for H694A/H694B
MEB-SEN Connection Cable, JW-230B
for stimulation
Surface electrode
For Installation
H634 NM-312S, Ag/AgCl disk electrode, 1 m lead
Cart, KD-030AJ, with 100 to 120 V isolation power unit
H638 NM-315S, Ag/AgCl disk electrode, 1.8 m lead
Cart, KD-030AK, with 220 to 240 V isolation power
Evoked potential electrode kit
unit
H852A NE-132B, 1.5 m cable, disk electrode × 5 +
Power unit, SC-230B, 100 to 120 V isolation power
jumper lead
unit
H854 NE-142B, 0.5 m cable, for ABR, disk electrode
Power unit, SC-230BK, 220 to 240 V isolation power
× 5 + jumper lead
unit
H503A NE-113A, 1.5 m, 26 pcs/set
Stand, KC-001A
H503B NE-114A, 0.5 m, 26 pcs/set
LCD Stand, KH-122A, stand for dual displays on KD-
H528 NE-136B, 0.3 m, 3 pcs/set
030A
K617C NE-432B, shorting lead, DIN type, disk
Arm, KH-230B
electrode with a shielded lead
Arm, KH-231B
Concentric needle electrode (4 pcs/set)
Holder, DI-230B, for JB-206B/212B on KC-001A
H630 NM-121T, 20 mm long, 0.45 mm dia
Holder, DI-410B, for SEN-4100 on KD-030A
H650 NM-131T, 30 mm long, 0.45 mm dia
Power cord UL, YZ-001A1
H631 NM-151T, 50 mm long, 0.45 mm dia
Power cord N, YZ-001A3
H651 NM-320T, 20 mm long, 0.30 mm dia
System power cable, YZ-001A8, 50 cm
H652 NM-330T, 30 mm long, 0.30 mm dia
System power cable, YZ-001A9, 160 cm
Extension cable
System power cable, YZ-002A0, 250 cm
K611 BM-121S, for concentric needle electrode and
single fiber electrode, 1 m
Ground electrode
K623 BM-115S, for concentric needle electrode and
H658 NM-550B, disk type, 1.5 m
single fiber electrode, 1.8 m
H658A NM-551B, disk type, 0.3 m
EEG needle electrode
H664 NM-503B, child wrist, 1.5 m
H537A NE-224S, 1.5 m lead, 20 pcs/set
H664A NM-505B, child wrist, 0.3 m
Disposable concentric EMG needle electrode (25
H662 NM-501B, adult wrist, 1.5 m
pcs/set)
H662A NM-506B, adult wrist, 0.3 m
NM-125C, 25 mm long, 0.30 mm dia, red
H663 NM-502B, adult ankle
NM-325C, 25 mm long, 0.40 mm dia, yellow
Surface stimulation electrode
NM-437C, 37 mm long, 0.45 mm dia, green
H636 NM-420S, adult, 8 mm dia, 23 mm distance, 2
NM-450C, 50 mm long, 0.45 mm dia, blue
m lead, with a stimulation electrode strap
NM-575C, 75 mm long, 0.60 mm dia, violet
H646 felt tip, for H636
Extension cord
H671 stimulation electrode strap, 2 pcs/set, for H636
BM-325C, for disposable concentric needle EMG
H635 NM-410S, child, 4 mm dia, 10 mm distance, 2
electrode, 1.25 m
m lead, with a stimulation electrode strap
Biopolar needle electrode (2 pcs/set)
H647 felt tip, for H635
H632 NM-220T, 20 mm long, 0.4 mm dia
H670 stimulation electrode strap, 2 pcs/set, for H635
H633 NM-250T, 50 mm long, 0.4 mm dia
H637 NM-430S, variable distance type
H653 NM-450S, finger electrode, 2 m
6
Extension cable
K612 BM-211S, for bipolar needle electrode, 1 m
K624 BM-215S, for bipolar needle electrode, 1.8 m
Monopolar needle electrode, Teflon coating (5 pcs/
set)
H666 NM-715S, 15 mm long, 0.30 mm dia
H667 NM-730S, 30 mm long, 0.30 mm dia
H668 NM-830S, 30 mm long, 0.40 mm dia
H669 NM-850S, 50 mm long, 0.40 mm dia
Monopolar needle electrode
H665 NM-710T, 13 mm long, 0.25 mm dia, 5 pcs/set
Extension cable
K620 BM-800S, for monopolar needle electrode, with
6-pin connector, 1 m
Disposable monopolar EMG needle electrode (25
pcs/set)
NM-225U, 25 mm long, 0.35 mm dia, red
NM-425U, 25 mm long, 0.45 mm dia, yellow
NM-237U, 37 mm long, 0.35 mm dia, orange
NM-437U, 37 mm long, 0.45 mm dia, green
NM-450U, 50 mm long, 0.45 mm dia, blue
NM-475U, 75 mm long, 0.45 mm dia, violet
Extension cord
BM-315U, for disposable monopolar needle electrode,
1 m, 5 pole DIN connector
Disposable monopolar EMG needle electrode,
prewired (0.75 m), DIN connector (25 pcs/set)
NM-225B, 25 mm long, 0.35 mm dia, red
NM-425B, 25 mm long, 0.45 mm dia, yellow
NM-237B, 37 mm long, 0.35 mm dia, orange
NM-437B, 37 mm long, 0.45 mm dia, green
NM-450B, 50 mm long, 0.45 mm dia, blue
NM-475B, 75 mm long, 0.45 mm dia, violet
Single-fiber electrode
H660 NM-640T, 30 mm long, 0.45 mm dia
Extension cable
K619 BM-840S, for concentric/single-fiber macro
EMG electrode with 6-pin connectors, 1 m
Macro EMG electrode
H650A NM-130S, concentric, 30 mm long, 0.45 mm
dia
H661 NM-640S, single-fiber, 30 mm long, 0.45 mm
dia
Collodion Electrode, DIN
H526 NE-134A, 1.5 m lead, 12 pcs/set
H527 NE-136A, 0.7 m lead, 12 pcs/set
Electrocochleogram silver ball electrode
H850 YZ-0073, 10 pcs/set, 0.6-1 mm dia ball, 100
mm lead
ERG contact lens electrode
H831 KE-L, for adult
H832 KE-S, for child

EEG paste
F510 Z-401CE, 400 g × 3 jars, Elefix
F509 Z-181JE, 180 g × 10 tubes, Elefix
F507 Z-181BE, 180 g × 2 tubes, Elefix
Skin preparation gel
F020 YZ-0019, 135 g × 2 tubes, SkinPure

7
ORDERING INFORMATION
When ordering, please specify the following informa-
tion:
1) Power line voltage and its frequency
2) Requirements for optional accessories
3) Requirements for consumables
4) Specify part order code in for consumables

This brochure may be revised or replaced by Nihon Kohden at any time without notice.

TD.No.MEB-2300 NK100210 (0210) Printed in Japan