Professional Documents
Culture Documents
Release 9.0
The Nokia 7705 Service Aggregation Router (SAR) portfolio provides service
adaptation, aggregation, and routing over an efficient, feature-rich Ethernet
and IP/MPLS/segment routing infrastructure. With interfaces supporting a
wide range of access protocols, it is well suited for mobile backhaul, fixed-
mobile convergence, mission-critical and enterprise applications.
1 Data sheet
Nokia 7705 Service Aggregation Router
Routing and resiliency Quality of service
The depth of its IP/MPLS/segment routing protocol Service Router Operating System (SR 0S) software
implementation and robust OAM capabilities at all provides superior quality of service (QoS) on the
levels set the 7705 SAR apart from its competitors. 7705 SAR. The same level of deep buffering and
A thorough implementation of the standards support for ingress and egress shaping that is
provides greater resiliency and more options available on Nokia’s edge and core routing platforms
and flexibility for service definition. is also available on the 7705 SAR aggregation
The 7705 SAR’s IP and MPLS scale gives network platform. Consistency of traffic engineering and
operators the potential to grow their networks, shaping across the network provides higher packet
adding many end users and applications without routing performance overall with differentiated
having to make additional capital investment. service treatment. This facilitates the convergence
of fixed and mobile traffic for service providers as
The 7705 SAR provides excellent resiliency to link well as operational and business services traffic
or equipment failures through redundancy and for mission-critical network operators. SR OS
the ability to quickly reroute traffic. The 7705 software allows for advanced service offerings, and
SAR delivers network reconvergence in tens of delivers efficient network resource usage, customer
milliseconds using a strong suite of dynamic satisfaction and retention.
routing and recovery capabilities. Superior network
resiliency reduces network down time and improves Precise timing and synchronization
operations staff’s productivity, helping to reduce The 7705 SAR provides microsecond timing and
operating costs, improve end-user satisfaction, accurate synchronization to support mobile base
and allowing service providers to offer higher-value station requirements and the migration of TDM-
service level agreements (SLAs). based services onto the packet network. Timing
accuracy and performance over packet are enabled
Robust security
with a combination of built-in architectural features,
The 7705 SAR provides a robust set of security integrated Global Navigation Satellite System (GNSS)
features to maintain network integrity in the face receivers, Nokia Bell Labs algorithms, accurate
of cyberattacks such as session hijacking, spoofing, hardware time-stamping, and powerful QoS
and denial of service attacks. The 7705 SAR firewall mechanisms, which minimize the delay and delay
is application-aware and mitigates attacks, such variation experienced by synchronization traffic.
as Domain Name System (DNS)/Internet Control
Message Protocol (ICMP) replay. It uses application- Microwave awareness
level gateways to ensure extra security for FTP/T- When used together, the 7705 SAR and Wavence
FTP connections. 7705 SAR hardware-based Microwave systems have a number of features that
encryption features, including IPSec, Network Group improve routing performance and resiliency over
Encryption and advanced key exchange algorithms, microwave links. A 7705 SAR router and its sub-
prevent man-in-the-middle attacks. All 7705 SAR tending microwave systems are treated as a single
security features provide high throughput levels network element with one IP address, simplifying
while minimizing latency. operations and administration. This allows for
The portfolio is FIPS 140-2 compliant on both the bandwidth notification, IEEE 1588 synchronization,
control and data planes. Operators can use the faster fault detection, and rerouting with various
7705 SAR to safeguard critical infrastructures and microwave redundancy architectures supported.
address regulatory requirements, such as North The microwave systems can be powered from the
American Electric Reliability Corporation (NERC) 7705 SAR system reducing space and cost.
Critical Infrastructure Protection Version 5 (CIP V5).
2 Data sheet
Nokia 7705 Service Aggregation Router
Field longevity –– Metro Ethernet Forum (MEF) 8 - Implementation
The Nokia 7705 SAR portfolio is packaged in a wide Agreement for the Emulation of PDH Circuits
range of form factors to accommodate the density over Metro Ethernet Networks
and types of services required at any location. It • Raw socket IP transport for asynchronous RS-232
provides both indoor and outdoor mounting solutions serial data
combined with extended temperature range and
power-over-Ethernet (PoE) options. Fanless and Interfaces
conformal-coated variants allow the 7705 SAR to • Ethernet
be used in harsh environmental conditions. • Packet over SONET/SDH (POS)
7705 SAR platforms are mechanically hardened • Asynchronous Transfer Mode (ATM), ATM-Inverse
with a robust electromagnetic compatibility (EMC) Multiplexing over ATM (IMA)
design. Several platforms comply with the IEEE
1613, IEC 61850-3 and EN 50121-4 standards • Frame Relay (FR)
for power substations and railway environments. • High Level Data Link Control (HDLC)
• Point-to-Point Protocol (PPP), Multi-Class (MC)
Software features PPP, Multi-Link (ML) PPP
7705 SAR models support, but are not limited to, • Time Division Multiplexing (TDM)
the following features:
Network protocols
Services • Segment routing with traffic engineering (TE)
• Point-to-point Layer-2 virtual private network –– Intermediate System-to-Intermediate System
(VPN) services (IS-IS) and Open Shortest Path First (OSPF) TE
–– Ethernet VPN - Virtual Private Wire Service extensions
(EVPN-VPWS) –– Topology-independent loop-free alternate
–– Virtual leased line (VLL)/Pseudowire (LFA) (IS-IS)
- Targeted Label Distribution Protocol (T-LDP)- –– Path Computational Element Protocol (PCEP)
based ATM, frame relay HDLC, IP, Ethernet support
and TDM Pseudowires • MPLS Label Edge Router (LER) and Label Switch
• Multi-point layer-2 Virtual Private LAN Service (VPLS) Router (LSR) functions
–– EVPN-VPLS –– Resource Reservation Protocol — Traffic
- Route type 2: MAC/IP advertisement Engineering (RSVP-TE)
- Route type 3: Inclusive multicast (without - RSVP-TE Label Switched Path (LSP) shortcuts
point to multi-point) Ethernet tag route for for Interior Gateway Protocol (IGP) route
broadcast, unknown unicast and multicast traffic resolution
–– T-LDP-based VPLS - PCEP support
• IP VPN services (IPv4 and IPv6) –– Label Distribution Protocol (LDP) with LFA
and remote LFA
• Internet Enhanced Service (IES)
• IP routing
• Circuit Emulation Services (CES)
–– IS-IS (IPv4, IPv6)
–– Structure Agnostic TDM over Packet (SAToP)
–– OSPFv2 and OSPFv3
–– Circuit Emulation Service over Packet-Switched
Network (CESoPSN) –– Constraint-based Shortest Path First (CSPF)
3 Data sheet
Nokia 7705 Service Aggregation Router
–– Routing Information Protocol (RIP) • RSVP-TE
–– Border Gateway Protocol (BGP) with • Automatic Protection Switching (APS) and MC APS
multiprotocol extensions for SONET/SDH
–– BGP label unicast routes as defined in RFC 3107 • IPv4 and LDP LSR equal-cost multi-path (ECMP)
• IPv6 • Virtual Router Redundancy Protocol (VRRP)
–– IPv6 VPN Provider Edge (6VPE) for MPLS and • Asymmetric delay control over redundant network
IPSec VPRN paths
–– Dynamic Host Configuration Protocol (DHCP) • Line card redundancy (LCR) for DS1/E1 ports
v6 server/relay • Non-stop routing, non-stop services
–– IPv6 over IPSecv4 tunnels • ITU-T G.8032v2 Ethernet ring protection
–– LDPv6 switching
• Multicast functionality at L3 and L2 Timing and synchronization
–– L2 multicasting via Internet Group • External reference and line timing
Management Protocol (IGMP)/Multicast Listener
• Adaptive Clock Recovery (ACR) timing
Discovery (MLD) snooping in VPLS with traffic
flow from L3 to L2 • Differential Clock Recovery (DCR) timing
–– IGMP/MLD snooping translation into Protocol • DCR-serial mode on the 12-port SDIv3 adapter
Independent Multicast (PIM) for Routed VPLS card
(RVPLS) • Built-in Stratum-3 clock
–– Protocol Independent Multicast – Source Specific • ITU-T Synchronous Ethernet (Sync-E)
Multicast (PIM-SSM) with both IGMPv1/2/3 and
MLD v1/2 Label Distribution Protocol (LDP) • IEEE 1588v2
• PIM (SM, SSM) stitching via L2 PIM snooping –– Master Clock (MC), Boundary Clock (BC),
Slave Clock (SC), Transparent Clock (TC)
• Next generation multicast VPNs with MP-BGP
MVPN-IPv4 address family and dynamic MLDP –– Time of day (ToD) output port
PMSI tree –– User Datagram Protocol (UDP)/IP (v4 and v6)
• Targeted LDP (T-LDP) and Ethernet encapsulation
• Generic Routing Encapsulation (GRE) –– Default IEEE 1588v2 profile, ITU-T G.8265.1
profile
Load balancing and resiliency –– ITU-T G.8275.1 full on-path and G.8275.2
• IEEE 802.3.ad Link Aggregation Group (LAG) partial on-path profiles
and multi-chassis (MC) LAG
• GNSS receiver (various models)
• Pseudowire redundancy
–– IEEE 1588v2 grandmaster
• Primary and secondary LSPs
–– Frequency, phase and time distribution
• Fast reroute (FRR)
• RFC 1305 Network Time Protocol (Version 3) -
–– BGP Specification, Implementation and Analysis
–– IP (OSPF and ISIS) • RFC 5905 Network Time Protocol (NTP)
–– LDP with loop-free alternate (LFA) policies • Inter-range instrumentation group (IRIG)-B
–– LDP LFA via segment routing stitching (B000/B12x) (7705 SAR-H)
4 Data sheet
Nokia 7705 Service Aggregation Router
Quality of service and traffic management
• Hierarchical QoS (H-QoS)
Hardware features
The 7705 SAR is available in a range of models
• Intelligent packet classification, policing, scheduling to suit a broad range of applications. Select
• Deep buffering 7705 SAR products are also available with
conformal coating as an orderable option to
• Ingress and egress shaping on per forwarding
provide added protection against environmental
class, service access point (SAP) or VLAN,
contaminants.
per customer multi-service site (MSS) and
port basis
Security
• Simple Network Management Protocol (SNMP) v3
• Secure Shell (SSH)
• IP Security (IPSec) encryption over MPLS
• Network address translation (NAT)
• L2 services (VLL, VPLS over GRE) over IPSec
• TCP Maximum Segment Size (MSS) adjustment
for IPSec
• Stateful firewall
• Network Group Encryption for IP/MPLS services, L3
user and control traffic, and select L2 control traffic
• Public Key Infrastructure (PKI) supporting X.509v3
certificates, Certificate Management Protocol version
2 (CMPv2), Certificate Revocation List (CRL), Online
Certificate Status Protocol (OCSP), RSA/DSA keys
• FIPS 140-2 compliant
5 Data sheet
Nokia 7705 Service Aggregation Router
Table 1. 7705 SAR platform specifications (part 1)123
7705 SAR-X 7705 SAR-M1 7705 SAR-82 7705 SAR-183
(2 variants based (2 variants based
on power supply) on port configuration)
System throughput 54 Gb/s half duplex (HD) 10 Gb/s (HD) 60 Gb/s (HD) 140 Gb/s (HD)
Capacity for adapter None 1 slot • 2 x 10 Gb/s full duplex • 12 x 2.5 Gb/s (FD) slots
cards/modules (FD) slots • 4 x 10 Gb/s (FD) XMDA
per chassis • 4 x 2.5 Gb/s (FD) slots adapter card slots
Built-in interfaces • 2 x SFP+ 10 Gb/s • 4 x SFP 10/100/1000 N/A N/A
• 8 x SFP 10/100/1000 Mb/s
Mb/s • 3 x RJ-45 10/100/1000
• 4 x Combo SFP/RJ-45 Mb/s
10/100/1000 Mb/s • Variant 1: additional
• 8 x RJ-45 T1/E1 16 x RJ-45 T1/E1
• Variant 2: no additional
ports
Timing ports Sync in, ToD/1PPS out Sync in, Sync out, ToD Sync in, Sync out, ToD in, 2 BITS ports
ToD out
Common equipment Power feeds, cooling fans Power feeds, cooling fans Control, switch fabric, power Control, switch fabric, power
redundancy feeds, cooling fans feeds, cooling fans
Dimensions • Height: 1 RU 4.37 cm • Height: 1 RU 4.4 cm • Height: 2 RU, 8.9 cm • Height: 10 RU, 44.5 cm
(1.72 in) (1.73 in) (3.5 in) (17.5 in)
• Depth: 25.4 cm (10 in) • Depth: 24.1 cm (9.5 in) • Depth: 26.4 cm (10.4 in) • Depth: 30 cm (11.8 in)
• Width: 44.2 cm (17.4 in) • Width: 44.1 cm (17.4 in) • Width: 44.5 cm (17.5 in) • Width: 43.9 cm (17.3 in)
• Rack-mountable in a • Rack-mountable in a • Rack-mountable in a • Rack-mountable in a
48.2-cm rack, 30-cm 48.2-cm rack, 30-cm 48.2-cm rack, 30-cm 48.2-cm rack, 30-cm
depth (standard 19-in depth (standard 19-in depth (standard 19-in depth (standard 19-in
equipment rack, 12-in equipment rack, 12-in equipment rack, 12-in equipment rack, 12-in
depth) depth) depth) depth)
Power Variant 1: • Two feeds: -48 V DC/ • Two feeds: -48 V DC/ • Two feeds: -48 V DC/
• Two feeds: -48 V DC/ -60 V DC, or +24 V DC -60 V DC, or +24 V DC -60 V DC
-60 V DC, or +24 V DC • AC power solutions • AC power solutions • AC power solutions
Variant 2: available: 100 V AC to available: 100 V AC to available: 200 V AC to
240 V AC, 50 Hz/60 Hz 240 V AC, 50 Hz/60 Hz 277 V AC, 50 Hz/60 Hz
• One feed: 100 V AC to
240 V AC, 50 Hz to 60 Hz
Cooling Built-in five-fan array Built-in five-fan array One tray of eight fans One tray of eight fans
with redundancy with redundancy with redundancy with redundancy
Normal operating -40°C to +65°C -40°C to +65°C -40°C to +65°C • -5°C to +45°C
temperature range (-40°F to +149°F) (-40°F to +149°F) (-40°F to +149°F) (23°F to 113°F) sustained
sustained sustained sustained • -5°C to +55°C
(23°F to 131°F)
extended (96 hours)
Normal humidity 5% to 95%, 5% to 95%, 5% to 95%, • 5% to 85%,
non-condensing non-condensing non-condensing non-condensing
• Short-term (96 hours)
extended humidity
range: 5% to 95%,
non-condensing
Shipping and storage -40°C to +70°C -40°C to +70°C -40°C to +70°C -40°C to +70°C
temperature (-40°F to +158°F) (-40°F to +158°F) (-40°F to +158°F) (-40°F to +158°F)
6 Data sheet
Nokia 7705 Service Aggregation Router
Table 2. 7705 SAR platform specifications (part 2)4
System throughput 10 Gb/s (HD) 10 Gb/s (HD) 8 Gb/s (HD) 5 Gb/s (HD)
Capacity for modules 2 slots
per chassis
Built-in interfaces • 4 x Combo SFP/RJ-45 • 4 x Combo SFP/RJ-45 • 4 x RJ-45 10/100/1000 • 2 x RJ-45 10/100/1000
10/100/1000 Mb/s 10/100/1000 Mb/s (PoE/PoE+ capable) (PoE/PoE+ capable)
• 8 x SFP 10/100/1000 • 4 x SFP 10/100/1000 • 2 x SFP 100/1000 Mb/s • 2 x RJ-45 10/100/1000
Mb/s Mb/s • 2 x Combo SFP/RJ-45 Mb/s
• 4 x RJ-45 10/100 Mb/s 100/1000 Mb/s • 2 x SFP 100/1000 Mb/s
• Variant 1: additional • 2 x RS-232 (async)
8 x RJ-45 T1/E1
• Variant 2: no additional
ports
Timing ports Sync in, ToD/1PPS out, Sync in, ToD out Sync in, Sync out, GNSS,
GNSS IRIG-B out
Dimensions • Height: 1 RU 4.3 cm • Height: 1 RU 4.4 cm • Height: 1.7 RU 7.62 cm • Height: 17.8 cm (7 in)
(1.7 in) (1.73 in) (3 in) • Width: 9.14 cm (3.6 in)
• Depth: 20.1 cm (7.9 in) • Depth: 24.1 cm (9.5 in) • Depth: 25.4 cm (10 in) • Depth: 15.24 cm (6 in)
• Width: 43.79 cm • Width: 44.1 cm (17.4 in) • Width: 43.9 cm (17.3 in) • DIN rail and wall/
(17.24 in) • Rack-mountable in a • Rack-mountable in a panel-mountable
• Rack-mountable in a 48.2-cm rack, 30-cm 48.2-cm rack, 30-cm
48.2-cm rack, 30-cm depth (standard 19-in depth (standard 19-in
depth (standard 19-in equipment rack, 12-in equipment rack, 12-in
equipment rack, 12-in depth) depth)
depth) • Wall/panel-mountable
Power • Two feeds: -48 V DC/ • Two feeds: -48 V DC/ • Low voltage DC variant: • ±20 V DC to 75 V DC
-60 V DC, or +24 V DC -60 V DC Two feeds: -48 V DC/ • HV power solution
• AC power solutions • AC power solutions -60 V DC, or +24 V DC available: 100 V AC to
available: 100 V AC to available: 100 V AC to • High voltage AC/DC 240 V AC, 50 Hz/60 Hz;
240 V AC, 50 Hz/60 Hz 240 V AC, 50 Hz/60 Hz variant: 88 V DC to 300 V DC
– Rated voltages: 110 V
DC to 250 V DC, 100 V
AC to 240 V AC,
50 Hz/60 Hz
Cooling Passively cooled Passively cooled Passively cooled Passively cooled
Normal operating • -40°C to +65°C (-40°F to • -40°C to +65°C (-40°F to -40°C to +65°C • -40°C to +70°C5
temperature range +149°F) sustained with a +149°F) sustained with a (-40°F to +149°F) (-40°F to +158°F)
minimum airflow rate of minimum airflow rate of sustained sustained with a
0.5 m/s 0.5 m/s minimum airflow rate
• -40°C to +60°C • -40°C to +60°C of 0.5 m/s
(-40°F to +140°F) (-40°F to +140°F) • -40°C to +65°C
in a still air environment in a still air environment (-40°F to +149°F)
in a still air environment
Normal humidity 5% to 95%, 5% to 95%, 5% to 95%, 5% to 95%,
non-condensing non-condensing non-condensing non-condensing
Shipping and storage -40°C to +70°C -40°C to +70°C -40°C to +70°C -40°C to +70°C
temperature (-40°F to +158°F) (-40°F to +158°F) (-40°F to +158°F) (-40°F to +158°F)
7 Data sheet
Nokia 7705 Service Aggregation Router
Table 3. 7705 SAR platform specifications (part 3)
8 Data sheet
Nokia 7705 Service Aggregation Router
7705 SAR-8 and SAR-18 adapter cards5
The 7705 SAR portfolio supports an extensive range of adapter cards and modules, optimized to address
different network and service requirements. Each of the six adapter card slots in the 7705 SAR-8, or the
12 adapter card slots in the right side of the 7705 SAR-18, can be used to house the following adapter
card types.
6 See 7705 SAR Legacy Interface Adapter Cards data sheet for more details
9 Data sheet
Nokia 7705 Service Aggregation Router
7705 SAR-H modules
The two expansion module slots, provided on the 7705 SAR-H, can support the plug-in modules
in Table 7.
Standards compliance
Tables 8 through 12 provide information on how the 7705 SAR variants comply with international
regulatory and telecom standards.
10 Data sheet
Nokia 7705 Service Aggregation Router
Standard Title 7705 7705 7705 7705 7705 7705 7705 7705 7705
SAR-X SAR-A SAR Ax SAR-M SAR-8 SAR-18 SAR-H SAR-Hc SAR-Wx
IEC 62236- Electromagnetic Compatibility X X X X X X X X X
4 – Part 4: Emission and
Immunity of the Signalling and
Telecommunications Apparatus
11 Data sheet
Nokia 7705 Service Aggregation Router
Standard Title 7705 7705 7705 7705 7705 7705 7705 7705 7705
SAR-X SAR-A SAR Ax SAR-M SAR-8 SAR-18 SAR-H SAR-Hc SAR-Wx
IEC 61000- Ripple on d.c. input power port X X X X X X
4-17 immunity test
IEC 61000- Damped oscillatory wave X X X X X X
4-18 immunity test
IEC 61000- Voltage dips, short interruptions X X X X X X
4-29 and voltage variations on d.c.
input power port immunity
tests
IEC 61000- Limits for harmonic current X X9 X9 X9 X9 X9 X X9 X
3-2 emissions (equipment input
current <16A per phase)
IEC 61000- Limits for voltage fluctuations X X9 X9 X9 X9 X9 X X9 X
3-3 and flicker in low-voltage supply
systems for equipment with
rated current <16A
12 Data sheet
Nokia 7705 Service Aggregation Router
Standard Title 7705 7705 7705 7705 7705 7705 7705 7705 7705
SAR-X SAR-A SAR Ax SAR-M SAR-8 SAR-18 SAR-H SAR-Hc SAR-Wx
Telcordia EMC and Electrical Safety – X X X X X X X X X
GR-1089- Generic Criteria for Network
CORE Telecommunications
Equipment
AS/NZS Information technology X10 X10 X10 X10 X10 X10 X10 X10 X11
CISPR 32 equipment – Radio disturbance
characteristics – Limits and
methods of measurement
FCC Part Radio Frequency devices- X10 X10 X10 X10 X10 X10 X10 X10 X11
15, Unintentional Radiators
Subpart B (Radiated & Conducted
Emissions)
ICES-003 Information Technology X10 X10 X10 X10 X10 X10 X10 X10 X11
Equipment (ITE) —
Limits and methods
of measurement
EN 55032 Electromagnetic compatibility X10 X10 X10 X10 X10 X10 X10 X10 X11
of multimedia equipment -
Emission requirements
CISPR 32 Electromagnetic compatibility X10 X10 X10 X10 X10 X10 X10 X10 X11
of multimedia equipment -
Emission requirements
footnotes678910111213141516
1 Performance Class 1
2 Performance Class 1 (Class 2 with optics interfaces only)
3 Performance Class 2
4 Zone A; Performance Class 1
5 Zone A; Performance Class 1 (Class 2 with optics interfaces only)
6 Zone B; Performance Class 1
7 Zone A; Performance Class 2
8 With the exception of DC surges
9 With external AC/DC power supply
10 Class A
11 Class B
13 Data sheet
Nokia 7705 Service Aggregation Router
Table 9. Environmental standards compliance
Standard Title 7705 7705 7705 7705 7705 7705 7705 7705 7705
SAR-X SAR-A SAR Ax SAR-M SAR-8 SAR-18 SAR-H SAR-Hc SAR-Wx
IEEE 1613:2009 + A1:2011 Environmental and X1 X1 X1 X1 X X
Testing Requirements
for Communications
Networking Devices
IEC 61850-3 Communication X2 X2 X2 X2 X2 X2
networks and systems
for power utility
automation -
Part 3: General
requirements
IEC 60068-2-1 Environmental testing – X X X X X X X X X
Part 2-1: Tests –
Test A: Cold
IEC 60068-2-2 Environmental testing – X X X X X X X X X
Part 2-2: Tests -
Test B: Dry heat
14 Data sheet
Nokia 7705 Service Aggregation Router
Standard Title 7705 7705 7705 7705 7705 7705 7705 7705 7705
SAR-X SAR-A SAR Ax SAR-M SAR-8 SAR-18 SAR-H SAR-Hc SAR-Wx
footnotes1718192021
15 Data sheet
Nokia 7705 Service Aggregation Router
Table 10. Safety standards compliance
Standard Title 7705 7705 7705 7705 7705 7705 7705 7705 7705
SAR-X SAR-A SAR Ax SAR-M SAR-8 SAR-18 SAR-H SAR-Hc SAR-Wx
UL/CSA Information technology X X X X X X X X X
60950-1 equipment -
Safety - Part 1: General
requirements
16 Data sheet
Nokia 7705 Service Aggregation Router
Table 11. Telecom interface compliance
Standard Title 7705 7705 7705 7705 7705 7705 7705 7705 7705
SAR-X SAR-A SAR Ax SAR-M SAR-8 SAR-18 SAR-H SAR-Hc SAR-Wx
IC CS-03 Compliance Specification for Terminal X X X X X X
Issue 9 Equipment, Terminal Systems,
Network Protection Devices,
Connection Arrangements and
Hearing Aids Compatibility
ACTA TIA- Telecommunications - Telephone X X X X X X
968-B Terminal Equipment - Technical
Requirements for Connection
of Terminal Equipment to the
Telephone Network
AS/ACIF Requirements for Customer X X X X X X
S016 Equipment for connection to
(Australia) hierarchical digital interfaces
ATIS- Network and Customer X X X X X X
06000403 Installation Interfaces-
DS1 Electrical Interfaces
ANSI/TIA/ Electrical Characteristics X X
EIA-422-B for balanced voltage digital
(RS-422) interfaces circuits
ITU-T G.825 The control of jitter and wander X X
within digital networks which
are based on the synchronous
digital hierarchy (SDH)
ITU-T G.703 Physical/electrical characteristics X X X X X X
of hierarchical digital interfaces
ITU-T G.712 Transmission performance X X
(E&M) characteristics of pulse code
modulation channels
ITU-T G.957 Optical interfaces for X X
equipments and systems
relating to the synchronous
digital hierarchy
ITU-T V.24 List of definitions for X X X X
(RS-232) interchange circuits between
data terminal equipment (DTE)
and data circuit-terminating
equipment (DCE)
ITU-T V.28 Electrical characteristics for X X
(V.35) unbalanced double-current
interchange circuits
ITU-T V.36 Modems for synchronous data X X
(V.35) transmission using 60-108 kHz
group band circuits
ITU-T Electrical characteristics for X X
V.11/X.27 balanced double current
(RS-422) interchange circuits operating at
data signalling rates up to 10 Mb/s
ITU-T X.21 Interface between Data Terminal X X
(RS-422) Equipment and Data Circuit-
terminating Equipment for
synchronous operation on
public data networks
IEEE Data Terminal Equipment X X X X
802.3at Power via the Media Dependent
(POE) Interfaces Enhancements
17 Data sheet
Nokia 7705 Service Aggregation Router
Table 12. Directives, regional approvals and certifications
Standard Title 7705 7705 7705 7705 7705 7705 7705 7705 7705
SAR-X SAR-A SAR Ax SAR-M SAR-8 SAR-18 SAR-H SAR-Hc SAR-Wx
EU Directive Electromagnetic Compatibility X X X X X X X X X
2014/30/EU (EMC)
(EMC)
EU Directive Low Voltage Directive (LVD) X X X X X X X X X
2014/35/EU
(LVD)
CE Mark X X X X X X X X X
CRoHs Logo; X X X X X X X X X
Ministry of
Information
Industry order
No.39
China X X X X X
(MII NAL)
Network
Access License
South Korea X X X X X X X X
(KC Mark)
Australia X X X X X X X X X
(RCM Mark)
Japan X X X X X X X
(VCCI Mark)
NEBS Level 3 X X X X X X X X X
TL9000 X X X X X X X X X
certified
ISO 14001 X X X X X X X X X
certified
ISO 9001: X X X X X X X X X
2008 certified
18 Data sheet
Nokia 7705 Service Aggregation Router
About Nokia
We create the technology to connect the world. Powered by the research and innovation of Nokia Bell Labs, we serve communications service providers, governments, large
enterprises and consumers, with the industry’s most complete, end-to-end portfolio of products, services and licensing.
From the enabling infrastructure for 5G and the Internet of Things, to emerging applications in digital health, we are shaping the future of technology to transform the
human experience. networks.nokia.com
Nokia operates a policy of ongoing development and has made all reasonable efforts to ensure that the content of this document is adequate and free of material errors
and omissions. Nokia assumes no responsibility for any inaccuracies in this document and reserves the right to change, modify, transfer, or otherwise revise this publication
without notice.
Nokia is a registered trademark of Nokia Corporation. Other product and company names mentioned herein may be trademarks or trade names of their respective owners.
© 2019 Nokia
Nokia Oyj
Karaportti 3
FI-02610 Espoo, Finland
Tel. +358 (0) 10 44 88 000