You are on page 1of 8

JPT REVIEW CENTER

E-DESIGN (Truck Hub)

Name: Date:
Student Number: Score:

Title and General Description  The carwash is a single-lane carwash


A Proposed Truck Hub / Mixed-Use good for four cars at a time, the
Development covered structure measuring 12
meters x 8 meters.
Statement of the Problem
 A covered water and air island
A successful businessman wants to expand
measuring 1 meter x 3 meters will be
his business by venturing into the trucking
provided for the gasoline station.
industry. Already owning a fleet of trucks for
his current businesses, he saw the need for The middle portion is 3,740 sqm. in area and
integrated truck hubs – mixed-use facilities has a depth of 85 meters. It will be used for
incorporating gas refilling stations with light industrial uses (truck parking,
offices and warehouses. He chose you to warehouses).
design his first such truck hub using his
 On its north side, directly adjacent to
property in Batangas.
the internal access road, is an open,
The site will be divided into three main paved truck parking area measuring
areas: a front portion, a middle portion, and 8 meters deep x 85 meters long.
a rear portion.  On the east and west sides,
meanwhile, are landscape buffer
The front portion will be 60 meters deep
areas measuring 2.50 meters wide
with an area of 2,640 sqm. Since it is directly
and 36 meters long. They are
accessible from the road, it will be used for
elongated unpaved areas, starting
commercial purposes, housing a gasoline
from the south side of the property
station, a carwash, and a one-storey
and terminating at the truck parking
commercial building.
area previously described.
 There will be a one-lane gas refilling  After the truck parking area, there is
canopy, with six pumps and a cashier another open area before the
booth. Five underground fuel warehouses on the south side. This
storage tanks, each measuring open area will serve as the loading
4920mm x 2040mm, will be and unloading zone, with the same
provided. depth as the truck parking area but
 The commercial building measures with an area of only 640 sqm. It is
28 m. x 12 m. It contains an internet flanked on both sides by the
café, a few spaces for commercial landscape buffer areas.
tenants, and a toilet.  The remaining 28-meter deep area
on the south side of the middle

JPT REVIEW CENTER Page 1 of 8


portion contains two warehouses  A gazebo with an area of 6 meters x
and a general utility zone. 6 meters.
o The two warehouses are
located side-by-side and are
both 28 meters deep. Project Site Features
o The first one, located beside The site is 1-hectare inside lot with a 50-
the east landscape buffer, is meter frontage facing an 18-meter wide
40 meters long and has an highway on the east. The OBO has granted
area of 1,120 sqm. This the property a special (SPE) zoning
warehouse will be used for classification, and development control
heavy materials, such as entitlements and occupancy limitations
lumber, plywood, and metals. equal to that of the Commercial 3 zone (as
o Right beside it is the second specified in the IRR of PD 1096).
warehouse, measures 28
To provide access to all portions of the
meters x 30 meters. This will
property, a 6-meter-wide internal access
be used for light storage,
road will be provided on the north side of
such as soft drinks, boxed
the property, spanning from the north end
goods, and snacks.
to the south end of the lot.
o The remaining portion in the
middle zone is 280 sqm. in The highest point of the lot is the southwest
area, and is located between corner, and the lowest point of the lot is the
the second, smaller northeast corner. The site slopes at 2% from
warehouse and the the former to the latter.
landscape buffer on the west
Design Objectives
side. This area will be used as
1. To maximize revenue for a faster
a general utility zone.
return of investment for the client.
The rear portion is a residential area for the 2. To properly design a mixed-use
client. It measures 44 meters x 55 meters development, ensuring the
and will contain the following compatibility of the mixed used, or
providing measures to mitigate the
 A two-storey house with a 320 sqm.
undesirable effects of less than ideal
building footprint and a TGFA of 560
combinations of uses.
sqm.
3. To use practical design and finishes
 A staff/driver’s house with a 300
for the commercial or revenue-
sqm. building footprint.
generating components of the
 A recreational area that includes a
project.
basketball court, a paved
playground, and a pool. Questions (45 Items)
 A covered parking area for at least
three vehicles.

JPT REVIEW CENTER Page 2 of 8


1. What is the minimum parking slot d. Both A and B
size required by the NBC for
standard trucks? 6. According to Table 8.1, what is the
a. 3.60m x 12.00m maximum total footprint allowed for
b. 3.60m x 18.00m the entire lot, assuming no firewalls
c. 3.60m x 20.00m will be used?
d. 3.60m x 22.00m a. 70% of TLA
b. 75% of TLA
2. What is the minimum parking slot c. 80% of TLA
size required by the NBC for d. 90% of TLA
articulated trucks?
a. 3.60m x 12.00m 7. If the owner wanted to add more
b. 3.60m x 18.00m buildings to this property, which
c. 3.60m x 20.00m building type would you least
d. 3.60m x 22.00m recommend?
a. A liquor shop
3. For the toilets located in the b. A printing shop
commercial building, what minimum c. A soap processing plant
dimension does the NBC require? d. A massage clinic
a. 600mm
b. 750mm 8. What is the maximum building
c. 900mm height allowed for this property?
d. 1200mm a. 60 floors
b. 16 floors
4. If the commercial building will be c. 48 floors
artificially ventilated, what is the d. 180 floors
minimum ceiling height required by
the NBC? 9. What is the difference in elevation
a. 2.10m between the lowest and the highest
b. 2.40m points of the lot?
c. 2.70m a. Around 1.00 m
d. 3.20m b. Around 2.00 m
c. Around 4.00 m
5. If the gazebo is constructed one year d. Around 10.00 m
after the main house, would a
building permit still be required
before constructing it? 10. What is the recommended minimum
a. No. It is exempt because it is lot size for C-3?
an addition. a. 365 sqm
b. No. It is exempt because it is b. 600 sqm
small enough. c. 813 sqm
c. Yes. It is not exempt d. 10,000 sqm
because it is not small
enough.

JPT REVIEW CENTER Page 3 of 8


11. Based on Table VII.1 of PD 1096, of the commercial building’s
what is the maximum TGFA allowed footprint, how many 600mm x
for this property assuming that there 600mm homogenous tiles will be
will be no firewalls? required to finish the lobby? Add 4%
a. 30x75% for breakage, and 3% for attic stock.
b. 30x80% a. Around 150 pcs.
c. 30x85% b. Around 200 pcs.
d. 30x90% c. Around 250 pcs.
d. Around 300 pcs.
12. What is the maximum allowable
FLAR for the property? 17. If the front portion of the lot
a. 3.00 (containing the gas station, etc.) and
b. 3.60 the middle portion (containing the
c. 9.00 truck parking, warehouses, etc.) are
d. 34.00 separated by a 1800mm-high
masonry wall, how many pieces of
13. Based on the maximum allowable 100-mm thick CHB will be needed to
FLAR, what is the maximum construct the wall? Allow 5% for
allowable gross floor area for this breakage.
property? a. Around 500 pcs.
a. 340,000 sqm. b. Around 750 pcs.
b. 90,000 sqm. c. Around 1000 pcs.
c. 36,000 sqm. d. Around 1500 pcs.
d. 30,000 sqm.

14. The playground described in the 18. If 160 cubic yards of concrete are
problem is part of the needed and one truck carries 8 cubic
a. Impervious Surface Area yards of concrete, how many trucks
b. Unpaved Surface Area should be assigned to the job?
c. Construction Area Consider that the round trip time
d. Both A and C. takes 95 minutes during peak hours
and unloading at the jobsite
happens every 15 minutes.
15. If the eldest daughter decided to a. 6 trucks
turn a portion of the rear yard into a b. 7 trucks
vegetable garden, this area would be c. 10 trucks
part of the d. 20 trucks
a. ISA
b. USA
c. MACA 19. 1 cubic yard of common earth, when
d. Both A and C excavated, becomes loose and will
swell in volume to:
16. If the area of the lobby of the a. Around 2x its original volume
commercial building is equal to 20%

JPT REVIEW CENTER Page 4 of 8


b. Around 1.5x its original d. 36 feet
volume
c. Around 1.25x its original
volume
23. What minimum width is
d. No change. The volume of
recommended for two-way service
common earth in its loose
roads for trucks?
condition is the same as its
a. 12 feet
volume in its bank/in-situ
b. 18 feet
condition.
c. 24 feet
d. 36 feet

20. If 30 cubic yards of concrete are


24. For the circulation within and around
needed and one truck carries 10
the truck parking facility, which
cubic yards of concrete, how many
general circulation pattern is
trucks should be assigned to the
recommended?
job? Consider that the round trip
a. A generally clockwise
time takes 75 minutes during peak
circulation pattern
hours and unloading at the jobsite
b. A generally
happens every 15 minutes.
counterclockwise
a. 2 trucks
circulation pattern
b. 3 trucks
c. A circulation pattern that is
c. 5 trucks
neither clockwise nor
d. 10 trucks
counterclockwise
d. It does not really matter

21. For the truck parking lot, what


25. Which would be recommended to
minimum width would you
separate the rear residential portion
recommend for the gate if traffic will
from the middle truck
be two-way?
parking/warehouse area?
a. 16 feet
a. A 500mm-high wall, with
b. 28 feet
dense and tall vegetation on
c. 32 feet
the side of the truck parking
d. The parking lot should not
lot
have a gate
b. A 1800mm-high wall, with
dense and tall vegetation
on the side of the
22. What minimum width is
residential area
recommended for one-way service
c. A 700mm-high wall, with a
roads for trucks?
water feature on the side of
a. 12 feet
the residence
b. 18 feet
c. 24 feet

JPT REVIEW CENTER Page 5 of 8


d. No wall, just a natural fence d. At least 5 inches higher than
using gumamela shrubs and the sofa seat
small palm trees
30. How much clearance should be
26. Which finish would be provided from the edge of the
recommended for the paved dining table if passage only is
outdoor play area for the children? required (no seating)?
a. Homogeneous tiles, matte a. 250mm
finish b. 600mm
b. Natural stones like granite to c. 900mm
complement the garden d. 1200mm
c. Exterior-grade rubber
flooring 31. How much clearance should be
d. Concrete pavers with slots for provided in front of cabinets or
grass to grow through drawers in the bedroom, to ensure
that they can be used comfortably
27. Within the house, where would you despite the swing-out doors or
recommend to locate most of the drawers?
bedrooms? a. 450mm
a. North side b. 600mm
b. East side c. 900mm
c. West side d. 1200mm
d. South side
32. How high should the highest shelf in
28. How many people can sit around a the lavatory medicine cabinet be?
round dining table with a diameter a. Maximum of 1200mm
of 1500mm? b. Maximum of 1800mm
a. 4-5 people c. Maximum of 2000mm
b. 7-8 people d. Maximum of 2375mm
c. 9-10 people
d. More than 10 people 33. The owner requested a separate
“dirty” kitchen located in a semi-
29. The owner requested that the open space in the service core of the
architect find excellent locally- house. Since most of the heavy
produced furniture for the house. cooking and food preparation will
How tall should coffee tables in the happen here, which countertop
living room be? finish should be recommended to
a. At least 6 inches lower than the owner?
the sofa seat a. Stainless steel
b. It should be about the b. Homogeneous tiles
same height as the sofa c. Corian (Solid surface
seat countertop)
c. 250mm d. Plain concrete

JPT REVIEW CENTER Page 6 of 8


34. Which floor finish should be b. In the middle of the
recommended for the tenant spaces convenience store, to give
in the commercial building? the cashier a good view of
a. Tiles the entire store
b. Laminated wood c. Near the storage room
c. Granite d. Beside the manager’s desk
d. Marble
38. If the trucks will docked in a
35. For the commercial building parking sheltered area, what is the minimum
lot, if economy of space (e.g. as clear ceiling height recommended?
many parking slots in the smallest a. 3.70m
practicable space) is the primary b. 4.20m
concern, which is the better c. 5.20m
configuration? d. 6.00m
a. A central driveway with
two rows of cars and 90- 39. It is the downward movement of the
degree parking ground around an excavated space,
b. A central driveway with two such as that for tunnels, shafts, or
rows of cars and diagonal basements.
parking a. Compaction
c. Both are equally space- b. Settlement
efficient c. Liquefaction
d. This cannot be determined d. Impaction
until the parking lot is
actually used 40. This type of lighting is more energy-
efficient and more environment-
36. For the commercial building parking friendly than conventional choices.
lot, which parking slots should be a. Metal halide
made slightly wider than the other b. Fluorescent
parking slots? c. Incandescent
a. End slots, especially if d. LED
beside a building or a
driveway 41. Which of the following is an
b. Middle slots, because it is advantage of using metal decking in
harder to park construction?
c. Parking slots on either side of a. Less use of forms
a PWD parking slot b. Additional reinforcement to
d. Parking slots that may be the concrete floor
visible from the lobby c. This is an advantage in
fast-track construction
37. Where should the cashier’s counter d. Wide clear span framing
in a convenience store be located? system
a. Near the entrance/exit of
the store

JPT REVIEW CENTER Page 7 of 8


42. The parking provision for the rear
residential area is counted as part of
which?
a. ISA
b. USA
c. PSO
d. GFA

43. The truck parking area in the middle


portion is counted as part of which?
a. ISA
b. USA
c. PSO
d. GFA

44. What is the size of a basketball court


for college (in meters)?
a. 15 x 25
b. 15 x 26
c. 15 x 28
d. 15 x 29

45. What is the zoning classification for


this project?
a. SPE
b. Commercial
c. Residential
d. Mixed Use

JPT REVIEW CENTER Page 8 of 8