Professional Documents
Culture Documents
www.vishay.com
Vishay Semiconductors
0.5 A Output Current IGBT and MOSFET Driver
FEATURES
• 0.5 A minimum peak output current
NC 1 8 VCC • 25 kV/μs minimum common mode rejection
(CMR) at VCM = 1500 V
A 2 7 VO
• ICC = 2.5 mA maximum supply current
C 3 6 VO • Under voltage lock-out (UVLO) with
hysteresis
NC 4 5 VEE
Shield • Wide operating VCC range: 15 V to 32 V
20530_1 • 0.4 μs maximum propagation delay
V • Industrial temperature range: - 40 °C to 110 °C
D E
ORDERING INFORMATION
DIP-8 Option 7
V O 3 1 5 0 A - X 0 0 7 T
TRUTH TABLE
VCC - VEE VCC - VEE
LED “POSITIVE GOING” “NEGATIVE GOING” VO
(TURN ON) (TURN OFF)
Off 0 V to 32 V 0 V to 32 V Low
On 0 V to 11 V 0 V to 9.5 V Low
On 11 V to 13.5 V 9.5 V to 12 V Transition
On 13.5 V to 32 V 12 V to 32 V High
THERMAL CHARACTERISTICS
PARAMETER SYMBOL VALUE UNIT
LED power dissipation Pdiss 45 mW
TA
Output power dissipation Pdiss 250 mW
θDC θEC
Maximum output die junction temperature Tjmax. 125 °C
TJD θDE TJE
Thermal resistance, junction emitter to board θJEB 169 °C/W
TA
Thermal resistance, case to ambient θCA 2645 °C/W
Note
• The thermal model is represented in the thermal network below. Each resistance value given in this model can be used to calculate the
temperatures at each node for a given operating condition. The thermal resistance from board to ambient will be dependent on the type of
PCB, layout and thickness of copper traces. For a detailed explanation of the thermal model, please reference Vishay's Thermal
Characteristics of Optocouplers application note.
ELECTRICAL CHARACTERISTICS
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
IF = 16 mA, Rg = 10 Ω, Cg = 20 nF, (1)
High level output current IOH 0.5 - - A
VCC = 15 V, VEE = 0 V
IF = 0 mA, Rg = 10 Ω, Cg = 20 nF,
Low level output current IOL (1) 0.5 - - A
VCC = 15 V, VEE = 0 V
High level output voltage IO = -100 mA VOH (2) VCC - 4 VCC - 2.1 - V
Low level output voltage IO = 100 mA VOL - 0.2 0.5 V
High level supply current Output open, IF = 7 mA to 16 mA ICCH - - 2.5 mA
Low level supply current Output open, VF = -3 V to + 0.8 V ICCL - - 2.5 mA
Threshold input current low to high IO = 0 mA, VO > 5 V IFLH - 2.1 5 mA
Threshold input voltage high to low VFHL 0.8 - - V
Input forward voltage IF = 10 mA VF 1 1.3 1.6 V
Temperature coefficient of forward
IF = 10 mA ΔVF/ΔTA - - 1.4 - mV/°C
voltage
Input reverse breakdown voltage IR = 10 μA BVΡ 5 - - V
Input capacitance f = 1 MHz, VF = 0 V CIN - 60 - pF
VO ≥ 5 V VUVLO+ 11 12.6 13.5 V
UVLO threshold
IF = 10 mA VUVLO- 9.5 10.7 12 V
UVLO hysteresis UVLOHYS - 1.9 - V
Notes
• Minimum and maximum values were tested over recommended operating conditions (Tamb = - 40 °C to 110 °C, IF(ON) = 7 mA to 16 mA,
VF(OFF) = - 3 V to 0.8 V, VCC = 15 V to 32 V, VEE = ground) unless otherwise specified. Typical values are characteristics of the device and are
the result of engineering evaluations. Typical values are for information only and are not part of the testing requirements. All typical values
were measured at Tamb = 25 °C and with VCC - VEE = 32 V.
• Maximum pulse width = 50 μs, maximum duty cycle = 0.5 %.
(1) Maximum pulse width = 10 μs, maximum duty cycle = 0.2 %. This value is intended to allow for component tolerances for designs with
IO peak minimum = 0.5 A.
(2) In this test V
OH is measured with a dc load current. When driving capacitive loads VOH will approach VCC as IOH approaches zero A. Maximum
pulse width = 1 ms, maximum duty cycle = 20 %.
1 8 1 8
0.1 µF 0.1 µF
100 mA
+
2 7 4V
2 7
IF = 7 mA to
16 mA + VCC = 15 V + VCC = 15 V
to 32 V to 32 V
3 6 3 6
IOH VOL
4 5 4 5
20973_1
20974_1
1 8 1 8
0.1 µF 0.1 µF
IOL
2 7 2 7
+ VCC = 15 V
to 32 V IF + VCC = 15 V
VO > 5 V to 32 V
+ 3 6
3 6 2.5 V
4 5 4 5
20976_1
20975_1
1 8 8
1
0.1 µF
0.1 µF
VOH
2 7
2 7
IF = 7 mA + VCC = 15 V
to 16 mA to 32 V IF = 10 mA + VCC
3 6 VO > 5 V
3 6
100 mA
4 5
4 5
20978
20977_1
SWITCHING CHARACTERISTICS
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
Propagation delay time to logic Rg = 47 Ω, Cg = 3 nF, f = 10 kHz,
tPHL 0.1 - 0.4 μs
low output (1) duty cycle = 50 %
Propagation delay time to logic Rg = 47 Ω, Cg = 3 nF, f = 10 kHz,
tPLH 0.1 - 0.4 μs
high output (1) duty cycle = 50 %
Rg = 47 Ω, Cg = 3 nF, f = 10 kHz,
Pulse width distortion (2) PWD - - 0.2 μs
duty cycle = 50 %
Propagation delay difference Rg = 47 Ω, Cg = 3 nF, f = 10 kHz,
PDD (tPHL - tPLH) -0.35 - 0.35 μs
between any two parts (3) duty cycle = 50 %
Rg = 47 Ω, Cg = 3 nF, f = 10 kHz,
Rise time tr - 0.1 - μs
duty cycle = 50 %
Rg = 47 Ω, Cg = 3 nF, f = 10 kHz,
Fall time tf - 0.1 - μs
duty cycle = 50 %
UVLO turn on delay VO > 5 V, IF = 10 mA TUVLO-ON - 0.8 - μs
UVLO turn off delay VO > 5 V, IF = 10 mA TUVLO-OFF - 0.6 - μs
Notes
(1) This load condition approximates the gate load of a 1200 V/25 A IGBT.
(2) Pulse width distortion (PWD) is defined as |t
PHL - tPLH| for any given device.
(3) The difference between t
PHL and tPLH between any two VO3150A parts under the same test condition.
1 8
0.1 µF IF
I F = 7 mA to 16 mA
+ VCC = 15 V
2 7 to 32 V tr tf
500 Ω
+ VO
10 kHz 90 %
50 % duty 3 6 47 Ω
50 %
cycle
3 nF 10 %
OUT
4 5
t PLH t PHL
20979_1
dV V CM
1 8 =
IF dt Δt
0.1 μF
A
R 2 7 0V
+ + Δt
5V VO
3 6 V CC = 32 V V OH
VO
Switch at A: IF = 10 mA
4 5
VO V OL
Switch at B: IF = 0 mA
+
20980-1
V CM = 1500 V
0.0 2.5
IF = 16 mA
IOH - High Output Current (A)
IF = 16 mA
Rg = 10 Ω, Cg = 20 nF
IOUT = - 100 mA
VOH - VCC - High Output
VEE = 0 V
- 1.0
1.5
- 1.5
1.0
- 2.0
0.5
- 2.5
- 3.0 0.0
- 40 - 20 0 20 40 60 80 100 120 - 40 - 20 0 20 40 60 80 100 120
21705-1 Temperature (°C) 21759 Temperature (°C)
Fig. 9 - High Output Voltage Drop vs. Temperature Fig. 10 - High Output Current vs. Temperature
0.35 -1
0.30 VCC = 15 V
- 1.5 VEE = 0 V
0.25
Drop (V)
0.20
-2
0.15
- 40 °C
VF(OFF) = 0.8 V
0.10 - 2.5
IOUT = 100 mA
25 °C
VCC = 32 V
0.05 110 °C
VEE = 0 V
0.00 -3
- 40 - 20 0 20 40 60 80 100 120 0 0.2 0.4 0.6 0.8
21707-1 Temperature (°C) 21762 IOH - Output High Current (A)
Fig. 11 - Output Low Voltage vs. Temperature Fig. 14 - Output High Voltage Dropvs. Output High Current
2.5 2.5
IF = 0 mA
IOL - Output Low Current (A)
1.0 1.0
IF = 16 mA for ICCH
0.5 IF = 0 mA for ICCL
0.5
VCC = 32 V
VEE = 0 V
0.0 0.0
- 40 - 20 0 20 40 60 80 100 - 40 - 20 0 20 40 60 80 100 120
21760 Temperature (°C) 21710-1 Temperature (°C)
Fig. 12 - Output Low Current vs. Temperature Fig. 15 - Supply Current vs. Temperature
2 2.5
IF = 0 mA IF = 10 mA for ICCH
VOL - Output Low Voltage (V)
IF = 0 mA for ICCL
ICC - Supply Current (mA)
VCC = 15 V
VEE = 0 V 25 °C 2.0 TA = 25 °C
1.5 VEE = 0 V
110 °C 1.5
ICCH
1
- 40 °C 1.0
ICCL
0.5
0.5
0 0.0
0.0 0.2 0.4 0.6 0.8 15 20 25 30 35
21761 IOL - Output Low Current (A) 21711 VCC - Supply Voltage (V)
Fig. 13 - Output Low Voltage vs. Output Low Current Fig. 16 - Supply Current vs. Supply Voltage
5.0 500
VCC = 32 V VCC = 32 V, VEE = 0 V
4.5
Fig. 17 - Low to High Current Threshold vs. Temperature Fig. 20 - Propagation Delay vs. Temperature
35 500
TA = 25 °C VCC = 30 V, VEE = 0 V
400 Rg = 47 Ω, Cg = 3 nF
25 Duty cycle = 50 %
f = 10 kHz
300
20
tPHL
15 200
tPLH
10
100
5
0 0
0 1 2 3 4 5 6 8 10 12 14 16
21752 IF - Forward LED Current (mA) 21738 IF - Forward LED Current (mA)
Fig. 18 - Transfer Characteristics Fig. 21 - Propagation Delay vs. Forward LED Current
500 500
IF = 10 mA, TA = 25 °C VCC = 30 V, VEE = 0 V
tp - Propagation Delay (ns)
Rg = 47 Ω, Cg = 3 nF IF = 10 mA, TA = 25 °C
Duty cycle = 50 % 400 Cg = 3 nF
400 Duty cycle = 50 %
f = 10 kHz
f = 10 kHz
300
300
tPLH
tPHL 200
tPHL
200
tPLH 100
100 0
15 20 25 30 35 0 10 20 30 40 50
21736 VCC - Supply Voltage (V) 21739 Rg - Series Load Resistance (Ω)
Fig. 19 - Propagation Delay vs. Supply Voltage Fig. 22 - Propagation Delay vs. Series Load Resistance
500
VCC = 30 V, VEE = 0 V
tp - Propagation Delay (ns)
IF = 10 mA, TA = 25 °C
400 Rg = 47 Ω
Duty cycle = 50 %
f = 10 kHz
300
tPLH
200
tPHL
100
0
0 20 40 60 80 100
21740 Cg - Series Load Capacitance (nF)
Pin one ID
4 3 2 1
6.645 ± 0.165
ISO method A
5 6 7 8
9.77 ± 0.14
0.95 ± 0.19
7.62 typ.
0.79
4° typ.
3.555 ± 0.255
6.095 ± 0.255
1.27 10°
0.70 ± 0.19 3.045 ± 0.255
3° to 9°
0.51 ± 0.05
2.54 typ.
0.25 ± 0.05 i178006
Option 7
7.62 typ.
0.7 4.6
4.1
8 min.
8.4 min.
V XXXX 68
21764-43
Notes
• XXXX = LMC (lot marking code)
• VDE logo is only marked on option 1 parts. Option information is not marked on the part
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay's knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product
with the properties described in the product specification is suitable for use in a particular application. Parameters provided in
datasheets and / or specifications may vary in different applications and performance may vary over time. All operating
parameters, including typical parameters, must be validated for each customer application by the customer's technical experts.
Product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited
to the warranty expressed therein.
Hyperlinks included in this datasheet may direct users to third-party websites. These links are provided as a convenience and
for informational purposes only. Inclusion of these hyperlinks does not constitute an endorsement or an approval by Vishay of
any of the products, services or opinions of the corporation, organization or individual associated with the third-party website.
Vishay disclaims any and all liability and bears no responsibility for the accuracy, legality or content of the third-party website
or for that of subsequent links.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.