You are on page 1of 7
‘SmartAX MAS6QOT/MAS603T/MAS608T Multiservice ‘Access Module Commissioning and Configuration Guide L Commissioning User Attribute Description Authority Users are classified into three levels: common user, operator, and ‘administrator. NOTE ‘According tothe operation authority, users of the MASGOOT/MAS6O3T MAS6OST are classified into four levels: common user, operator, administrator and super use. The user at one level ean add only the user a a lower level. The following lists the authority of all users. ‘© Common users can perform basic system operations and simple query ‘operations. ‘© Operators can configure the device and the services (© Forthe adminis and differences and the super user, they have the following similarities (© Perform all configurations (© Maintain and manage the device, user account, and user authority. © Differences: © Only one super user exists in the system; however, multiple administrators can coexist in the system. (© The super user can add an administrator, but an administrator has no authority to add the superuser Permitted reenter number ‘The permitted reenter number determines whether a user name can be used to log in to the system from several terminals at the same time. The permitted reenter number ranges from 0 to 4, and is generally set to 1 Appended information Appended information is a type of additional information about the user It consists of a string of 0-30 characters. It or the address of a user. Procedure Step 1 Run the terminal user name command to add a user that is consistent with the actual data plan, Step 2 Run the display terminal user command to query the user information —End Result ‘The queried user infomation isthe seme asthe actual data plan Example ‘With the administrator authority, to adda common user with the account at huawel, password as test01, user profile as the default root user profile, user level as Common User, permitted reenter number a6 3, and appended information as user, do as follows huawei (contig tannin uae name Imac 0 GUISE) Tawi Propritay and Confidential B Copyright © Huawei Technologies Co,, Lt. ‘SmartAX MAS6QOT/MAS603T/MAS608T Multiservice ‘Access Module Commissioning and Configuration Guide L Commissioning ford (ength<é, 159) :test01//the paseward se not displayed on the operator:a Nanber ( fon? (y/a) Enis uae: (config) #digplay terminal us Modifying the System User Attributes This topic describes how to modify the attributes of a system user, including the password, user profile, authority, permitted reenter number, and appended information in the case that the user attributes are not consistent with the current data plan. Prerequisites For details about the user authority, see "Context", Context ‘Table 1-21 lists the user attributes that can be modified and the related restrictions, Table 1-21 Modifying the user attributes User Attribute | Restriction Password © ‘Thesuperuserand the administrator can change their own passwords and the passwords of users at lower levels. When changing the password of a user at a lower level, the super user and the administrator need not input the old password. © The common user and the operator can change only their own, passwords, but they must input their old passwords for this purpose. User profile © The super user and the administrator can modify the profiles bound to them and the prc ss bound to users at lower levels. © The user name and the password must mect the specifications described in the user profile to be bound, Otherwise, the binding operation fails. Authority ‘The super user and the administrator can modify the authority of users at lower levels. In addition, the super user and the administrator can modify the user authority only to a level lower than them, Issue 02 (2013-07-25) Huawei Proprictary and Confidential o Copyright © Huawei Technologies Co,, Lt. ‘SmartAX MAS6QOT/MAS603T/MAS608T Multiservice ‘Access Module Commissioning and Configuration Guide L Commissioning Procedure Step1 Step2 Result Example User Attribute _| Restriction Permitted reenter | @ ‘The super user and the administrator can change the permitted number reenter number ofa user at a lower level © The permitted reenter number of the super user cannot be changed. Appended © The super user and the administrator can modify their own appended information information and the appended information about users at lower levels. © The common user and the operator can modify only their own appended information. Modify the system user attributes. COnote Before modifying the user atributes, run th to be modified play terminal user command to query the user attributes © Run the terminal user password command to change the password of a user ‘The password ofa user consists of 6-15 characters, in which at least one digit and one letter must be contained, The password is case sensitive, Run the terminal user user-profile command to modify the profile bound to a user. Run the terminal user level command to modify the authority of a user. Run the terminal user reenter command to change the permitted reenter number of a user Run the terminal user apdinfo command to modify the appended information about a ‘When the system has any problem, you can contact the userafter querying the user appended information. It is recommended that the user appended information be modified into the information that has the actual meaning, such as the contact means and the user address, Check the user information Run the display terminal user command to query the user information, —End ‘The queried user information is consistent with the user attributes that are modified, and login to the MAS600T/MAS603T/MAS608T by using the original user name and password is suceessfal To modify the attributes of user huawei, including changing the password to test02, user profile ‘0 operator profile, user level to operator, permitted reenter number to 4, and appended information to operator, do as follows: buawei (config) #terminal user password None (e=15 chars) shuawes Issue 02 (2013-07-25) Huawei Proprictary and Confidential 70 Copyright © Huawei Technologies Co,, Lt. ‘SmartAX MAS6OOT/MAS603T/MAS608T Multi-service ‘Access Module Commissioning and Configuration Guide L Commissioning re (lengrhc6, 18>) stest02//h jord (lengthc&, 15>) :tast02//The password is not displayed on che sawed (config) #Rerminal user userprofile (015 chars) chuawes, [root] :operator eroperator > (v/a) [n} im vswes (config) terminal user level eer Nane (< nuawed, al user reenter ars) shuay fem Reenter Nunber (0--a) 24 nformation will sake effect when this Repeat this operation? (y/n) [nim jer Wane (< ‘verminal user apdinto fare) huawei Repeat this eperazion? (y/a) (n uswe: (config) fdisplay terminal user name huawes Name Level Status Reenter Profile Append 1.3.11 Configuring a Board Specific services require specific boards, To use a board, you need to first confirm the automatically discovered board or add the board offline. Adding a Board Offline This topic describes how to add a board to an idle slot that is consistent with the board actually planned beforehand to ensure that the board runs immediately the board is installed in the slot Prerequisites The slot to which a board is added must be idle. Context © The boards other than the control board can be added offline. © After a board is added offline, the board status is displayed as Failed. The board status becomes normal only when a board of the same type as the board added offline is installed Issue 02 (2013-07-25) Huawei Proprictary and Confidential 7 Copyright © Huawei Technologies Co,, Lt. ‘SmartAX MAS6OOT/MAS603T/MAS608T Multi-service ‘Access Module Commissioning and Configuration Guide L Commissioning in the slot. If board of a different type is installed, the board resets repeatedly due to the board type mismatch. Procedure Step 1 Run the board add command to add a board offline. TD note (© The shelf ID and the slot ID of the board added ofiline must be the same as the actual position Otherwise, when the board is installed, the board status cannot be changed to normal ‘© The type ofthe board added offline must be the same as the type ofthe board installed. Otherwise, when the board is installed, the board status cannot be changed to normal Step 2 Run the display board frameid [/slotid J command to query the type of the added board. End Result ‘The type ofthe added board i the same a the board type that is planned, When aboard is installed in the sot in which the board is added, the board status is displayed as Normal Example To add a service board GPBD offline in slot 0/2, do as follows: viswes (config) #board add 0/2 RBO2gpbd buawes (config) #ddeplay Board 0/2 Board Nane ueo2ceaD In port of 0 in port of 0 n port of 0 Confirming a Board This topic describes how to confirm a board after the board installed in an idle slot is automatically discovered. This ensures that the auto-discovered board runs in the normal state. Issue 02 (2013-07-25) Huawei Proprictary and Confidential I Copyright © Huawei Technologies Co,, Lt. ‘SmartAX MAS60OT/MAS603T/MAS608T Multi-service ‘Access Module Commissioning and Configuration Guide L Commissioning Prerequisites A board must be installed in an idle slot or all the boards in the shelf must be installed. After that, the system automatically identifies the board type, and the board status is Auto_find. Procedure Step 1 Run the board confirm command to confirm an Auto_find board. nore © To confirm only one board, run the board confirm frameidisltid command, ‘© To.confirm al the boards ina shelf, run the board confirm frameid commend, Step 2 Run the display board frameid [/slotid J command to query the board status, —End Result ‘The board status is displayed as Normal. Example To confirm the service board in slot 0/2, do as follows: nvawes (config) board confirm 0/2 vawes (config) #dieplay board 0/2 abs. activating a 2 Checking the Board Status This topic describes how to check whether the board works in the normal state. Issue 02 (2013-07-25) Huawei Proprietary and Confidential 7 Copyright © Huawei Technologies Co,, Lt. ‘SmartAX MAS60OT/MAS603T/MAS608T Multi-service ‘Access Module Commissioning and Configuration Guide L Commissioning Procedure Step 1 Run the display board frameid command to query the status of all the boards, —End Result All the boards work in the normal state. That is all of the service board status is displayed as Normal, the active control board status is displayed as Active_normal, and the standby control board status is displayed as Standby_normal. Example To query the information about all the boards of shelf 0, do as follows: (contig) tddeplay board 0 4 neozapsp 6 e02GrRD Normal : = 14 weozerap 7 Reo2GPAD Korma’ 20 1.3.12 Checking the Status of the Upstream Port This topic describes how to check whether the upstream port is in the normal state. Procedure Step 1 Follow the steps below to check the status of the upstream port © [the control board is adopted for upstream transmission, do as follows: 1. Forthe MCU control board, run the interface meu command to enter the MCU mode, For other control boards, run the interface seu command to enter the SCU mode. 2. Run the display port state all command to check whether the upstream port is in the normal state. © Ifthe upstream board is adopted for upstream transmission, do as follows: Issue 02 (2013-07-25) Huawei Proprictary and Confidential 74 Copyright © Huawei Technologies Co,, Lt.

You might also like