You are on page 1of 25

INPUT / OUTPUT / POWER SUPPLY /

COMMUNICATION MODULES

CMC-99/141
MultiCon CMC I/O modules
Index

Power supply modules


PS32 ..................................... 5
PS42 ..................................... 5

Input modules
universal universal counters
EFUN4 ................................... 6 CP2 ........................................ 17
EFUN6 ................................... 6 CP4 ........................................ 17
QFUN4 ................................... 7
QFUN6 ................................... 7 hourmeters
UN3 ....................................... 8
HM2 ....................................... 18
UN5 ....................................... 8
HM4 ....................................... 18
current
I16 ......................................... 9 analogue flowmeters
I24 ......................................... 9 FI2 .......................................... 19
IS6 ......................................... 9 FI4 .......................................... 19
voltage pulse flow or ratemeters
U16......................................... 10
FT2 ......................................... 20
U24 ........................................ 10
FT4 ......................................... 20
voltage-current
UI4 ......................................... 11
UI8 ......................................... 11 Output modules
UI12 ....................................... 11 current
IO2 ........................................... 21
voltage-current-resistance
IO4 ........................................... 21
UI4N8 ..................................... 12 IO6 ........................................... 21
UI8N8 ..................................... 12 IO8 ........................................... 21

voltage-current-digital SSR
UI4D8 ..................................... 13 S8 ............................................. 22
UI8D8 ..................................... 13 S16 ........................................... 22
S24 ........................................... 22
thermocouple
TC4 ......................................... 14 relay
TC8 ......................................... 14 R45 ........................................... 23
TC12 ....................................... 14 R65 ........................................... 23
R81 ........................................... 23
RTD R121 ......................................... 23
RT4 ........................................ 15
RT6 ........................................ 15

digital Communication modules


D8 .......................................... 16 ETU .......................................... 24
D16 ........................................ 16 ACM ......................................... 24
D24 ........................................ 16 USB Host .................................. 24

www.multicon24.eu 2
MultiCon CMC I/O modules
Controllers, data recorders, HMI

The MultiCon line includes advanced controllers and data recorders with great potential closed in small
casings. MultiCon has been specifically designed for advanced applications in industrial automatic control
engineering. It does not mean, however, that the device cannot be applied in smaller systems. MultiCon can
be equipped with three isolated RS-485 interfaces which make it a perfect solution for distributed systems
to work as CPU. Thanks to Ethernet interface the device can be monitored via the Internet. A wide range of
input and output modules allows to customize CMC precisely as the customer requires it. Thanks to a colour
touchscreen working with the user interface becomes a pleasure, while MultiCon operation playing the role
of HMI is intuitive and comfortable. Our devices are LINUX-based products to ensure stable operation.

The biggest advantage of all devices from the MultiCon line is a big number of built-in inputs / outputs accessible in
one compact device. The most developed version CMC-99 has up to 48 measurement or digital inputs and 60 virtual
channels whereas CMC-141 has 50% more inputs / outputs and virtual channels.
Thanks to a well-thought-out module design you can choose among a wide range of modules and connect them to
slots in the way you wish but you do not have to use all slots. You can also decide on your own how to use virtual
channels, if they are going to be used for direct measurement readings, mathematical functions, timers, profile
creation, set points or virtual objects.
What if one day you want to change your configuration, add new modules or change their slots? That's not a problem!
All you have to do is to send your device to an authorized distributor who will perform the changes you require.

TECHNICAL DATA

CMC-99 CMC-141
Power supply/consumption 19-50V DC, 16-35V AC or 85-260V AC/DC, typ. 15 VA, max. 20 VA 19-50V DC, 16-35V AC or 85-260V AC/DC, typ. 25 VA, max. 35 VA
Display 3.5” graphic TFT, 16-bit colour, 320 x 240 pxs, touchscreen navigation 5.7” graphic TFT, 16-bit colour, 320 x 240 pxs, touchscreen navigation
Measurement inputs • up to 12 universal, isolated or unisolated: 0/4 ÷ 20 mA; 0/1 ÷ 5V, 0/2 • up to 18 universal, isolated or unisolated: 0/4 ÷ 20 mA; 0/1 ÷ 5V, 0/2
÷ 10V, 0 ÷ 30V; thermocouples: J, K, S, T, N, R, B, E (PN-EN), L (GOST); ÷ 10V, 0 ÷ 30V; thermocouples: J, K, S, T, N, R, B, E (PN-EN), L (GOST);
-10 ÷ 25 mV, -10 ÷ 100 mV, 0 ÷ 600 mV; RTD (2/3/4 wire): Pt100, -10 ÷ 25 mV, -10 ÷ 100 mV, 0 ÷ 600 mV; RTD (2/3/4 wire): Pt100,
Pt500, Pt1000 (PN-EN), Pt'50, Pt'100, Pt'500 (GOST), Ni100, Ni500, Pt500, Pt1000 (PN-EN), Pt'50, Pt'100, Pt'500 (GOST), Ni100, Ni500,
Ni1000 (PN-EN), Cu50, Cu100 (PN-83M-53852), Cu'50, Cu'100 (PN- Ni1000 (PN-EN), Cu50, Cu100 (PN-83M-53852), Cu'50, Cu'100 (PN-
83M-53852); resistance 0 ÷ 300 Ω, resistance 0 ÷ 3 kΩ 83M-53852); resistance 0 ÷ 300 Ω, resistance 0 ÷ 3 kΩ
• up to 48 analogue: 0/4 ÷ 20 mA, 0/1 ÷ 5V, 0/2 ÷ 10V • up to 72 analogue: 0/4 ÷ 20 mA, 0/1 ÷ 5V, 0/2 ÷ 10V
• up to 24 thermocouples: J, K, S, T, N, R, B, E (PN-EN); L (GOST); ± 25 • up to 36 thermocouples: J, K, S, T, N, R, B, E (PN-EN); L (GOST); ± 25
mV, ± 100 mV, -10 ÷ 25 mV, -10 ÷ 100 mV mV, ± 100 mV, -10 ÷ 25 mV, -10 ÷ 100 mV
• up to 12 RTD: Pt100, Pt500, Pt1000 (PN-EN); Pt'50, Pt'100, Pt'500 • up to 18 RTD: Pt100, Pt500, Pt1000 (PN-EN); Pt'50, Pt'100, Pt'500
(GOST); Ni100, Ni500, Ni1000 (PN-EN); Cu50, Cu100 (PN-83M- (GOST); Ni100, Ni500, Ni1000 (PN-EN); Cu50, Cu100 (PN-83M-
53852); Cu'50, Cu'100 (PN-83M-53852); 0 ÷ 300 Ω, 0 ÷ 3 kΩ 53852); Cu'50, Cu'100 (PN-83M-53852); 0 ÷ 300 Ω, 0 ÷ 3 kΩ
• up to 24 NTC: 0 ÷ 110 kΩ • up to 24 NTC: 0 ÷ 110 kΩ
• up to 12 counters: max. freq. 5 kHz • up to 12 counters: max. freq. 5 kHz
• up to 12 digital flowmeter / ratemeter: max. freq. 50 kHz • up to 12 digital flowmeter / ratemeter: max. freq. 50 kHz
• up to 12 analogue flowmeter: 0/4 ÷ 20 mA • up to 18 analogue flowmeter: 0/4 ÷ 20 mA
• mixed inputs: analogue-NTC temperature or analogue-digital: up to • mixed inputs: analogue-NTC temperature or analogue-digital: up to
12 x 0 ÷ 20 mA, 4 ÷ 20 mA and up to 12 x 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 24 x 0 ÷ 20 mA, 4 ÷ 20 mA and up to 24 x 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V,
2 ÷ 10V and up to 24 x NTC or digital 2 ÷ 10V and up to 24 x NTC or digital
Digital inputs • up to 49 * • up to 73 *
Outputs • up to 8 analogue 4 ÷ 20 mA, passive, isolated, resolution 12 bit • up to 24 analogue 4 ÷ 20 mA, passive, isolated, resolution 12 bit
• up to 16 SPST relay 1A/250V • up to 36 SPST relay 1A/250V
• up to 4 SPDT relay 5A/250V • up to 18 SPDT relay 5A/250V
• up to 48 SSR • up to 72 SSR
Sensor supply output • 1 x 24V DC ±5%, 200 mA max. • 1 x 24V DC ±5%, 200 mA max.
Communication Basic version: RS-485, 1 x USB Host, Basic version: RS-485, 1 x USB Host,
interface ETU: 1 or 2 x USB Host, 1 x Ethernet ETU: 1 or 2 x USB Host, 1 x Ethernet
ACM: 2 x RS-485, 1 x RS-485/232, 1 or 2 x USB Host, 1 x Ethernet ACM: 2 x RS-485, 1 x RS-485/232, 1 or 2 x USB Host, 1 x Ethernet
Protocols Modbus RTU Master/Slave, Modbus TCP Server, HTTP, Web Server, NTP Modbus RTU Master/Slave, Modbus TCP Server, HTTP, Web Server, NTP
IP rate protection IP 65 (device front side), options: IP 65 version including gasket for IP 65 (device front side), optional IP 65 version including gasket for
panel cut-out sealing or IP 54 transparent door with key; panel cut-out sealing or IP 54 transparent door with key;
IP 40 (front USB version) IP 40 (front USB version)
Operating temp. 0°C ÷ +50°C (optional -20°C ÷ +50°C) 0°C ÷ +50°C (optional -20°C ÷ +50°C)
Storage temp. -10°C ÷ +70°C (optional -20°C ÷ +70°C) -10°C ÷ +70°C (optional -20°C ÷ +70°C)
Data memory internal 2 GB (option 4 GB) internal 2 GB (option 4 GB)
Data recording speed from 0.1 s to 24 h with resolution 0.1 s from 0.1 s to 24 h with resolution 0.1 s
Dimensions case (WxHxD): 96 x 96 x 100 mm; panel cut-out: 90.5 x 90.5 mm case (WxHxD): 144 x 144 x 100 mm; panel cut-out: 137 x 137 mm
* one digital input is available in standard, integrated on PS32 or PS42 power supply.

3
MultiCon CMC I/O modules

MultiCon CMC-XX-P/D/C/B/A-XXX
options:
memory: 01: no options
version:
0: 2 GB 0C: PCB conformal coating
99 : 96 x 96 mm case
1: 4 GB 11: IP 65 gasket
141 : 144 x 144 mm case
1C: IP 65 gasket + PCB conformal coating
slot A - I/O module 81: operating temp. -20°C ÷ +50°C + PCB conformal coating
slot P - power supply module slot B - I/O module B1: front USB Host (IP 40)
BC: front USB Host (IP 40) + PCB conformal coating
slot D - communication module slot C - I/O module P1: IP 65 gasket + operating temp. -20°C ÷ +50°C
available modules listed below + PCB conformal coating
K1: front USB Host (IP 40) + operating temp. -20°C ÷ +50°C
Optional: LKS-99/141 Data logging licence key + PCB conformal coating
ENS-99/141 „E-mail notifications” licence key

Module Description MultiCon CMC-99 MultiCon CMC-141


type P D C B A P D C B A
PS32 19 ÷ 50V DC, 16 ÷ 35V AC power supply, 1 x digital input, 1 x RS-485 • •
PS42 85 ÷ 260V AC/DC power supply, 1 x digital input, 1 x RS-485 • •
E no communication module (available for 0B option only) • •
ETU communication module: 1 x USB Host, 1 x Ethernet 10 Mb/s • •
ACM advanced communication module: 1 x RS-485, 1 x RS-485/232, 1 x USB Host, 1 x Ethernet 10 Mb/s • •
USB USB port (back) • •
E empty slot • • • • • •
EFUN4 4 x universal inputs U/I/RTD/TC/mV (incl. totalizer on 0/4 ÷ 20 mA input), non-isolated • • • • • •
EFUN6 6 x universal inputs U/I/RTD/TC/mV (incl. totalizer on 0/4 ÷ 20 mA input), non-isolated • • •
QFUN4 4 x universal inputs U/I/RTD/TC/mV (incl. totalizer on 0/4 ÷ 20 mA input), isolated, new • • • • • •
QFUN6 6 x universal inputs U/I/RTD/TC/mV (incl. totalizer on 0/4 ÷ 20 mA input), isolated, new • • •
UN3 3 x universal inputs U/I/RTD/TC/mV, isolated • • • • • •
UN5 5 x universal inputs U/I/RTD/TC/mV, isolated • • •
I16 16 x current inputs • • • • • •
I24 24 x current inputs • • •
IS6 6 x current (4 ÷ 20 mA) inputs, isolated • • • • • •
U16 16 x voltage inputs • • • • • •
U24 24 x voltage inputs • • •
UI4 4 x voltage inputs + 4 x current inputs • • • • • •
UI8 8 x voltage inputs + 8 x current inputs • • • • • •
UI12 12 x voltage inputs + 12 x current inputs • • •
UI4N8 4 x voltage inputs + 4 x current inputs + 8 x NTC inputs • • • • • •
UI4D8 4 x voltage inputs + 4 x current inputs + 8 x digital inputs • • • • • •
UI8N8 8 x voltage inputs + 8 x current inputs + 8 x NTC inputs • • •
UI8D8 8 x voltage inputs + 8 x current inputs + 8 x digital inputs • • •
RT4 4 x RTD inputs • • • • • •
RT6 6 x RTD inputs • • •
TC4 4 x TC inputs • • • • • •
TC8 8 x TC inputs • • • • • •
TC12 12 x TC inputs • • •
D8 8 x digital inputs, isolated • • • • • •
D16 16 x digital inputs, isolated • • • • • •
D24 24 x digital inputs, isolated • • •
CP2 2 x pulse inputs, universal counters, isolated • • • • • •
CP4 4 x pulse inputs, universal counters, isolated • • • • • •
HM2 2 x hourmeters, isolated • • • • • •
HM4 4 x hourmeters, isolated • • • • • •
FT2 2 x pulse inputs (flowmeter/ratemeter), isolated + 2 x current inputs • • • • • •
FT4 4 x pulse inputs (flowmeter/ratemeter), isolated + 4 x current inputs • • • • • •
FI2 2 x current inputs (flowmeter/ratemeter) + 2 x current inputs • • • • • •
FI4 4 x current inputs (flowmeter/ratemeter) + 4 x current inputs • • • • • •
R81 8 x SPST relay 1A outputs • •* • • •
R121 12 x SPST relay 1A outputs • • •
R45 4 x SPDT relay 5A outputs • • • •
R65 6 x SPDT relay 5A outputs • • •
S8 8 x SSR driver outputs • • • • • •
S16 16 x SSR driver outputs • • • • • •
S24 24 x SSR driver outputs • • •
IO2 2 x 4 ÷ 20 mA outputs, isolated • • • • •
IO4 4 x 4 ÷ 20 mA outputs, isolated • • • • •
IO6 6 x 4 ÷ 20 mA outputs, isolated • • •
* The installation of the R81 module in slot B only in the case where in the slot C another relay module (R81 or R45) was installed.
IO8 8 x 4 ÷ 20 mA outputs, isolated • • •
* The installation of the R81 module in slot B only in the case where in the slot C another relay module (R81 or R45) was installed.
4
MultiCon CMC I/O modules
Power supply modules

PS32: 19V ÷ 50V DC; 16V ÷ 35V AC


PS42: 85V ÷ 260V DC or AC

PS32 and PS42 modules are used to supply the MultiCon.


PS32 module can be supplied with:
19V ÷ 50V DC
16V ÷ 35V AC

PS42 module can be supplied with:


85V ÷ 260V DC or AC

Additionally modules contain:


- service purpose input (service port),
- 24V DC output, used to supply external sensors,
- digital input, used for digital signal measurement,
PS42 - RS-485 port, used for communication with other devices
using Modbus protocol.

MODULE PIN ASSIGNMENT

PS32 PS42

1 1
Power supply
2 19V ÷ 50V DC 2 Power supply
16V ÷ 35V AC 85V÷260V AC/DC
Pin description:
PE PE
1, 2 : power supply connectors - supply voltage depends
on version, but polarization is irrelevant,
SERVICE
SERVICE 3 : ground for voltage output,
4 : +24V DC output, used to power external sensors,
3 GND 3 GND 5 : digital input - used to measure digital signals,
+24V DC ±5% +24V DC ±5%
4 Imax. = 200mA 4 Imax. = 200mA 6 : ground for connectors 5, 7, 8,
digital input digital input
5
0/15..24V DC
5
0/15..24V DC
7, 8 : data inputs for RS-485
6 GND 6 GND
7 B- 7 B-
RS-485 RS-485
8 A+ isolated 8 A+ isolated

TECHNICAL DATA

PS32 PS42

Number of inputs/outputs 5 5

Power supply 19V...24...50V DC; 16V...24...35V AC 85V...230...260 AC/DC; 50-60 Hz

USB Service Service port Service port

Sensor supply output 24V DC ±5% / max. 200 mA 24V DC ±5% / max. 200 mA

Digital input 0...15...24V DC with galvanic isolation 0...15...24V DC with galvanic isolation
(low state: 0 ÷ 1V, high state: 8 ÷ 24V) (low state: 0 ÷ 1V, high state: 8 ÷ 24V)
power consumption: 7,5 mA / 24V power consumption: 7,5 mA / 24V
isolation strenght: 1 min @ 500V DC isolation strenght: 1 min @ 500V DC

Interface RS-485, Modbus RTU, 1200 ÷ 115200 bit/sec. RS-485, Modbus RTU, 1200 ÷ 115200 bit/sec.

Weight 81 g 91 g

Part number M99-PS32-001 M99-PS42-001

www.multicon24.eu 5
MultiCon CMC I/O modules
Input modules - universal with totalizer

EFUN4: 4 unisolated universal inputs


EFUN6: 6 unisolated universal inputs

On customer's request, it is possible to install modules equipped with 4 or 6


universal unisolated inputs (incl. totalizer on 0/4 ÷ 20 mA input). Each
module includes a sensor for cold junction compensation. It is one of the
most advanced input modules, available for the MultiCon. With its help user
can make many different kind of measurements in each channel. This
module can measure: voltage, current, flow (analog), temperatures (TC or
RTD), digital signals (TTL or HTL).

MODULE PIN ASSIGNMENT


EFUN4 EFUN6
EFUN6 4 universal inputs 6 universal inputs
n01 +
n01 +

EFUN4 n02
V, mA
-
n02
V, mA
-
TC, mV TC, mV

IN1
IN1
n03 +
RTD
n03 +
RTD
EFUN modules parameters are: n04 n04
+ +
- Name - read-only input name given by the device, n05 n05
- -
- Unit - read-only field („°C”, „mA”, „V”, „Ohm” or „mV”), depending on Mode n06 n06

IN2

IN2
n07 + n07 +
parameter settings, n08
RTD
n08
RTD

- Mode - allows to set operation mode, eg. select a type of thermocouple or


mV measurement range or other,

IN_T
IN_T
- Low limit - defines measurement level below which in logical channel „Lo”
state will be displayed, n09 V, mA
+
n09 V, mA
+

- -
- High limit - defines measurement level above which in logical channel „Hi” n10 n10
TC, mV TC, mV

IN3

IN3
n11 + n11 +
state will be displayed, n12
RTD
n12
RTD

- Wire compensation - menu which allows to compensate measurement n13 +


n13 +

errors, which can be caused by wrong sensor readings, options: n14 -


n14 -

IN4

IN4
compensation mode (allows to choose parameter which will be used in n15 +
RTD
n15 +
RTD

compensation process), disable (compensation is not active), manual (allows n16 n16
+
n17
to compensate sensor constant offset), Pin description: n18
V, mA
-

- Actual temperature - parameter in which user enters actual temperature TC, mV

IN5
IN_T : Cold Junction n19 +
RTD
near the sensor, which is measured by more reliable thermometer. temperature n20
+
sensor n21
-
n22

IN6
n23 +
RTD
n24
TECHNICAL DATA

EFUN4 EFUN6
Number of inputs 4 (unisolated) 6 (unisolated)
Measurement ranges
current inputs: 0 ÷ 20 mA, 4 ÷ 20 mA 0 ÷ 20 mA, 4 ÷ 20 mA
voltage inputs: 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 2 ÷ 10V, 0 ÷ 30V, -10 ÷ 25mV, -10 ÷ 100mV, 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 2 ÷ 10V, 0 ÷ 30V, -10 ÷ 25mV, -10 ÷ 100mV,
0 ÷ 600mV 0 ÷ 600mV
digital inputs: TTL (Lo: 0 ÷ 0.8V; Hi: 2 ÷ 5.5V), HTL (Lo: 0 ÷ 4.2V; Hi: 11.5 ÷ 30V) TTL (Lo: 0 ÷ 0.8V; Hi: 2 ÷ 5.5V), HTL (Lo: 0 ÷ 4.2V; Hi: 11.5 ÷ 30V)
thermocouple inputs: J, K, S, T, N, R, B, E (PN-EN), L (GOST) J, K, S, T, N, R, B, E (PN-EN), L (GOST)
RTD inputs: (2, 3, 4-wire) Pt100, Pt500, Pt1000 (PN-EN), Pt'50, Pt'100, Pt'500 (GOST), Ni100, Pt100, Pt500, Pt1000 (PN-EN), Pt'50, Pt'100, Pt'500 (GOST), Ni100,
Ni500, Ni1000 (PN-EN), Cu50, Cu100 (PN-83M-53852), Cu'50, Cu'100 Ni500, Ni1000 (PN-EN), Cu50, Cu100 (PN-83M-53852), Cu'50, Cu'100
(PN-83M-53852) (PN-83M-53852)
resistance input: 0-300 Ω, 0-3 kΩ 0-300 Ω, 0-3 kΩ
Sampling period current, voltage, thermocouple inputs: 450 ms current, voltage, thermocouple inputs: 450 ms
RTD, resistance inputs: 1020 ms RTD, resistance inputs: 1020 ms
Precision 0,15% @ 25˚C (for -10 ÷ 25 mV); 0,1% @ 25˚C (others ranges) 0,15% @ 25˚C (for -10 ÷ 25 mV); 0,1% @ 25˚C (others ranges)
Input impedance current inputs: <65 Ω (30 Ω typ.) current inputs: <65 Ω (30 Ω typ.)
voltage inputs: >100 kΩ (while maintaining correct polarization) voltage inputs: >100 kΩ (while maintaining correct polarization)
TC inputs: ≥6 MΩ, RTD inputs: 4 kΩ TC inputs: ≥6 MΩ, RTD inputs: 4 kΩ
Weight 40 g 45 g
Part number M99-EFUN4-001 M141-EFUN6-001

6
MultiCon CMC I/O modules
Input modules - universal with totalizer

QFUN4: 4 isolated universal inputs


QFUN6: 6 isolated universal inputs

On customer's request, it is possible to install modules equipped with 4 or 6


universal isolated inputs (incl. totalizer on 0/4 ÷ 20 mA input). Each module
includes a sensor for cold junction compensation. It is one of the most
advanced input modules, available for the MultiCon. With its help user can
make many different kind of measurements in each channel. This module
can measure: voltage, current, flow (analog), temperatures (TC or RTD),
digital signals (TTL or HTL).

MODULE PIN ASSIGNMENT

QFUN6 QFUN4 QFUN6


4 universal inputs 6 universal inputs
n01 +
n01 +

QFUN4 n02
V, mA
-
n02
V, mA
-
TC, mV TC, mV

IN1
IN1
n03 +
RTD
n03 +
RTD
QFUN modules parameters are: n04 n04
+ +
- Name - read-only input name given by the device, n05 n05
- -
n06 n06
- Unit - read-only field („°C”, „mA”, „V”, „Ohm” or „mV”), depending on Mode

IN2

IN2
n07 + n07 +

parameter settings, n08


RTD
n08
RTD

- Mode - allows to set operation mode, eg. select a type of thermocouple or n09 +
n09 +
V, mA V, mA
mV measurement range or other, n10
TC, mV
-
n10
TC, mV
-

IN3
IN3
- Low limit - defines measurement level below which in logical channel „Lo” n11 +
RTD
n11 +
RTD
n12 n12
state will be displayed,
- High limit - defines measurement level above which in logical channel „Hi”

IN_T
IN_T
state will be displayed,
- Wire compensation - menu which allows to compensate measurement n13 +
n13 +

- -
errors, which can be caused by wrong sensor readings, options: n14 n14

IN4

IN4
compensation mode (allows to choose parameter which will be used in n15 +
RTD
n15 +
RTD
n16 n16
compensation process), disable (compensation is not active), manual (allows +
n17
to compensate sensor constant offset), Pin description: n18
V, mA
-

- Actual temperature - parameter in which user enters actual temperature IN_T : Cold Junction TC, mV

IN5
n19 +
RTD
near the sensor, which is measured by more reliable thermometer. temperature n20
sensor n21 +

-
n22

IN6
n23 +
RTD
n24
TECHNICAL DATA

QFUN4 QFUN6
Number of inputs 4 (isolated) 6 (isolated)
Measurement ranges
current inputs: 0 ÷ 20 mA, 4 ÷ 20 mA 0 ÷ 20 mA, 4 ÷ 20 mA
voltage inputs: 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 2 ÷ 10V, 0 ÷ 30V, -10 ÷ 25mV, -10 ÷ 100mV, 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 2 ÷ 10V, 0 ÷ 30V, -10 ÷ 25mV, -10 ÷ 100mV,
0 ÷ 600mV 0 ÷ 600mV
digital inputs: TTL (Lo: 0 ÷ 0.8V; Hi: 2 ÷ 5.5V), HTL (Lo: 0 ÷ 4.2V; Hi: 11.5 ÷ 30V) TTL (Lo: 0 ÷ 0.8V; Hi: 2 ÷ 5.5V), HTL (Lo: 0 ÷ 4.2V; Hi: 11.5 ÷ 30V)
thermocouple inputs: J, K, S, T, N, R, B, E (PN-EN), L (GOST) J, K, S, T, N, R, B, E (PN-EN), L (GOST)
RTD inputs: (2, 3, 4-wire) Pt100, Pt500, Pt1000 (PN-EN), Pt'50, Pt'100, Pt'500 (GOST), Ni100, Pt100, Pt500, Pt1000 (PN-EN), Pt'50, Pt'100, Pt'500 (GOST), Ni100,
Ni500, Ni1000 (PN-EN), Cu50, Cu100 (PN-83M-53852), Cu'50, Cu'100 Ni500, Ni1000 (PN-EN), Cu50, Cu100 (PN-83M-53852), Cu'50, Cu'100
(PN-83M-53852) (PN-83M-53852)
resistance input: 0-300 Ω, 0-3 kΩ 0-300 Ω, 0-3 kΩ
Sampling period current, voltage, thermocouple inputs: 450 ms current, voltage, thermocouple inputs: 450 ms
RTD, resistance inputs: 920 ms RTD, resistance inputs: 920 ms
Precision 0,15% @ 25˚C (for -10 ÷ 25 mV); 0,1% @ 25˚C (others ranges) 0,15% @ 25˚C (for -10 ÷ 25 mV); 0,1% @ 25˚C (others ranges)
Input impedance current inputs: <65 Ω (30 Ω typ.) current inputs: <65 Ω (30 Ω typ.)
voltage inputs: >100 kΩ (while maintaining correct polarization) voltage inputs: >100 kΩ (while maintaining correct polarization)
TC inputs: ≥6 MΩ, RTD inputs: 4 kΩ TC inputs: ≥6 MΩ, RTD inputs: 4 kΩ
Weight 64 g 82 g
Part number M99-EFUN4-001 M141-EFUN6-001

6
MultiCon CMC I/O modules
Input modules - universal

UN3: 3 isolated universal inputs


UN5: 5 isolated universal inputs

On customer's request, it is possible to install modules equipped with 3 or 5


universal inputs. Each module includes a sensor for cold junction
compensation. It is one of the most advanced input modules, available for
the MultiCon. With its help user can make many different kind of
measurements in each channel. This module can measure: voltage, current,
resistance, temperature using resistance sensors or thermocouples.

MODULE PIN ASSIGNMENT


UN3 UN5
UN5 3 universal inputs 5 universal inputs
UN3 n01 V, mA + n01
V, mA
+

- -
n02 n02
TC, mV TC, mV

IN1
IN1
n03 + n03 +
RTD RTD
UN modules parameters are: n04 n04
- Name - read-only input name given by the device, n05 n05
n06 +
n06 +
- Unit - read-only field („°C”, „mA”, „V”, „Ohm” or „mV”), depending on Mode - -
n07 n07
parameter settings, n08
TC, mV
n08
TC, mV

IN2
IN2
+ +

- Mode - allows to set operation mode, eg. select a type of thermocouple or n09
RTD
n09
RTD

mV measurement range or other, n10 n10


- Low limit - defines measurement level below which in logical channel „Lo”

IN_T
IN_T
state will be displayed,
- High limit - defines measurement level above which in logical channel „Hi”
+ +
state will be displayed, n11 n11
- -
n12 n12
- Wire compensation - menu which allows to compensate measurement TC, mV TC, mV
n13 n13

IN3
IN3
+ +

errors, which can be caused by wrong sensor readings, options: n14


RTD
n14
RTD

compensation mode (allows to choose parameter which will be used in n15 n15
compensation process), disable (compensation is not active), manual (allows n16 +

-
to compensate sensor constant offset), n17 TC, mV
n18

IN4
+
- Actual temperature - parameter in which user enters actual temperature RTD
n19
near the sensor, which is measured by more reliable thermometer. Pin description:
n20
IN_T : Cold Junction n21 +

temperature n22 -

sensor n23
TC, mV

IN5
+
RTD
n24
TECHNICAL DATA n25

UN3 UN5

Number of inputs 3 (isolated) 5 (isolated)

Measurement ranges
current inputs: 0 ÷ 20 mA, 4 ÷ 20 mA 0 ÷ 20 mA, 4 ÷ 20 mA
voltage inputs: 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 2 ÷ 10V, -10 ÷ 25mV, -10 ÷ 100mV, 0 ÷ 600mV 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 2 ÷ 10V, -10 ÷ 25mV, -10 ÷ 100mV, 0 ÷ 600mV
thermocouple inputs: J, K, S, T, N, R, B, E (PN-EN), L (GOST) J, K, S, T, N, R, B, E (PN-EN), L (GOST)
RTD inputs: (2, 3, 4-wire) Pt100, Pt500, Pt1000 (PN-EN), Pt'50, Pt'100, Pt'500 (GOST), Ni100, Pt100, Pt500, Pt1000 (PN-EN), Pt'50, Pt'100, Pt'500 (GOST), Ni100,
Ni500, Ni1000 (PN-EN), Cu50, Cu100 (PN-83M-53852), Cu'50, Cu'100 Ni500, Ni1000 (PN-EN), Cu50, Cu100 (PN-83M-53852), Cu'50, Cu'100
(PN-83M-53852) (PN-83M-53852)
resistance input: 0-300 Ω, 0-3 kΩ 0-300 Ω, 0-3 kΩ

Sampling period current, voltage, thermocouple inputs: 535 ms current, voltage, thermocouple inputs: 535 ms
RTD, resistance inputs: 1410 ms RTD, resistance inputs: 1410 ms

Precision 0,15% @ 25˚C (for -10 ÷ 25 mV); 0,1% @ 25˚C (others ranges) 0,15% @ 25˚C (for -10 ÷ 25 mV); 0,1% @ 25˚C (others ranges)

Input impedance current inputs: <65 Ω (30 Ω typ.) current inputs: <65 Ω (30 Ω typ.)
voltage inputs: >100 kΩ (while maintaining correct polarization) voltage inputs: >100 kΩ (while maintaining correct polarization)
TC inputs: >1,5 MΩ TC inputs: >1,5 MΩ

Weight 74 g 77 g

Part number M99-UN3-001 M141-UN5-001

www.multicon24.eu 7
MultiCon CMC I/O modules
Input modules - current

I16: 16 current inputs


I24: 24 current inputs
IS6: 6 isolated current inputs

MultiCon can be equipped with modules having 16 or 24 non isolated or 6


isolated current inputs. To make sensor connection easier, modules I16 and
I24 have inputs groupped into fours. IS6 module has all inputs separated one
from another and signal polarity on it's inputs has no matter.

MODULE PIN ASSIGNMENT


IS6
I16 I24 IS6
16 current inputs 24 current inputs 6 isolated current inputs
I16 n01 IN1 n01 IN1

4 x 0-20mA

4 x 0-20mA
IN2 IN2 n01
n02 n02 IN 1
n03 IN3 n03 IN3 n02
All GND terminals in the I16 and I24 modules are common
n04 IN4 n04 IN4
but separated from power supply and other modules.
n05 GND n05 GND

n06 IN5 n06 IN5

4 x 0-20mA

4 x 0-20mA
Current inputs parameters are: IN6 IN6 n03
n07 n07 IN 2
- Name - read-only input name given by the device, IN7 IN7 n04
n08 n08
- Unit - read-only field which displays measurement n09 IN8 n09 IN8
unit „mA”, n10 GND n10 GND
- Mode - defines measurement range (0-20 or 4-20), n11 IN9 4 x 0-20mA n11 IN9

4 x 0-20mA
- Low limit - defines measurement low limit, below n12 IN10 n12 IN10 n05
IN 3
which the device returns „Lo” value, n13 IN11 n13 IN11 n06
- High limit - defines measurement high limit, above n14 IN12 n14 IN12

which the device returns „Hi” value. n15 GND n15 GND

n16 IN13 n16 IN13


4 x 0-20mA

4 x 0-20mA
IS6
6 isolated current inputs n17 IN14 n17 IN14 n07
n01 IN 4
n02
IN 1
n18 IN15 n18 IN15 n08
Examplary connection for 2 - wire

n19 IN16 n19 IN16


sensors and IS6 module

n03

1 n04
IN 2
n20 GND n20 GND

n21 IN17
4 x 0-20mA

2 Power supply n05


IN18
(depending on version) Iin1 Iin2 n06
IN 3
n22 n09
IN19 IN 5
Sensor 1 Sensor 2 n23 n10
n07
SERVICE
n08
IN 4
n24 IN20

3 GND n25 GND


+24V DC ±5% (Imax. = 200mA)
4 n09
IN 5
n26 IN21
4 x 0-20mA

digital input n10


5
0/15..24V DC
6 IN22
7
GND
B-
n27 n11
RS-485 n11
IN 6
8 A+ n12
IN 6
n28 IN23
insulated
n12
n29 IN24

TECHNICAL DATA n30 GND

I16 I24 IS6

Number of inputs 16 24 6 (isolated)

Measurement range 0 ÷ 20 mA, 4 ÷ 20 mA 0 ÷ 20 mA, 4 ÷ 20 mA 4 ÷ 20 mA


Hardware limitation 0 mA ÷ 24 mA 0 mA ÷ 24 mA 3 mA ÷ 30 mA

Resolution 1 µA 1 µA 1 µA

Precision 0.1% @ 25°C 0.1% @ 25°C 0.25% @ 25°C

Temperature stability 50 ppm/˚C 50 ppm/˚C 65 ppm/˚C

Internal impedance type 100 Ω type 100 Ω type 1750 Ω @ 4 mA; type 400 Ω @ 20 mA

Protection 50 mA, auto-reset fuse 50 mA, auto-reset fuse 50 mA, auto-reset fuse

Sampling period 10 ms * 10 ms * 100 ms

Weight 42,5 g 63 g 39 g

Part number M99-I16-001 M141-I24-001 M99-IS6-001

* CMC reads data from modules every 100 ms

www.multicon24.eu 8
MultiCon CMC I/O modules
Input modules - voltage

U16: 16 voltage inputs


U24: 24 voltage inputs

On customer's request, the MultiCon device can be equipped with 16 or 24


voltage input modules.
To make sensor connection easier, inputs are grouped and all ground
terminals are common but separated from power supply and other modules.

MODULE PIN ASSIGNMENT


U16 U24
U16 16 voltage inputs 24 voltage inputs
IN1 IN1
n01 n01

4 x 0-10V

4 x 0-10V
IN2 IN2
n02 n02
n03 IN3 IN3
n03
n04 IN4 n04 IN4

Voltage input parameters are: n05 GND n05 GND


n06 IN5 n06 IN5
- Name - read-only input name given by the device,

4 x 0-10V

4 x 0-10V
n07 IN6 n07 IN6
- Unit - read-only field which displays measurement unit „V”, IN7 IN7
n08 n08
- Mode - defines measurement range (0 - 5V, 1 - 5V, 0 - 10V, 2 - 10V), IN8 IN8
n09 n09
- Low limit - defines measurement level below which in logical channel „Lo” n10 GND n10 GND
state will be displayed, IN9 IN9
n11 n11
- High limit - defines measurement level above which in logical channel „Hi”

4 x 0-10V

4 x 0-10V
n12 IN10 n12 IN10
state will be displayed. n13 IN11 n13 IN11

n14 IN12 n14 IN12

n15 GND n15 GND


Connections for 3 - wire sensor (voltage) IN13 IN13
U16
n16 n16

4 x 0-10V

4 x 0-10V
16 voltage inputs IN14 IN14
n01 IN1 n17 n17
4 x 0-10V

n02 IN2
n18 IN15 n18 IN15
n03 IN3

n04 IN4 n19 IN16 n19 IN16


n05 GND
1 n06 IN5 n20 GND n20 GND
4 x 0-10V

n07 IN6
n21 IN17
n08 IN7
2 Power supply

4 x 0-10V
(depending on version) Iin1 Iin2 n09 IN8
n22 IN18
n10 GND

Sensor 1 Sensor 2 n11 IN9 n23 IN19


4 x 0-10V

n12 IN10
SERVICE + - + -
IN11 n24 IN20
n13
IN12
3 GND
n14
GND
n25 GND
+24V DC ±5% (Imax. = 200mA) n15
4 IN21
5 digital input
n16 IN13
n26
4 x 0-10V

n17 IN14

4 x 0-10V
0/15..24V DC
6 GND
n18 IN15 n27 IN22
7 B- n19 IN16
RS-485 n28 IN23
8 A+ insulated n20 GND

n29 IN24

n30 GND

TECHNICAL DATA

U16 U24

Number of inputs 16 24

Measurement range 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 2 ÷ 10V 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 2 ÷ 10V
Hardware limitation 0V ÷ 12V 0V ÷ 12V

Hardware resolution 1 mV 1 mV

Precision 0.1% @ 25°C 0.1% @ 25°C

Temperature stability 50 ppm/˚C 50 ppm/˚C

Internal impedance 50 kΩ 50 kΩ

Sampling period 10 ms (CMC reads modules every 100 ms) 10 ms (CMC reads modules every 100 ms)

Weight 42 g 62,5 g

Part number M99-U16-001 M141-U24-001

www.multicon24.eu 9
MultiCon CMC I/O modules
Input modules - voltage/current

UI4: 4 voltage + 4 current inputs


UI8: 8 voltage + 8 current inputs
UI4
UI12: 12 voltage + 12 current inputs

The MultiCon UI modules include 8, 16 or 24 voltage / current inputs, mixed


where half of them are voltage and half are current.
To make sensor connection easier, inputs are grouped and all ground
terminals are common but separated from power supply and other modules.

UI8
MODULE PIN ASSIGNMENT
UI4 UI8 UI12
4 voltage 8 voltage 12 voltage
+ 4 current inputs + 8 current inputs + 12 current inputs
n01 IN1 n01 IN1 n01 IN1

4 x 0-20mA
4 x 0-20mA

4 x 0-20mA
n02 IN2 n02 IN2 n02 IN2

n03 IN3 n03 IN3 n03 IN3

n04 IN4 n04 IN4 n04 IN4


Voltage / current inputs parameters are:
- Name - read-only input name given by the device, n05 GND n05 GND n05 GND
n06 IN5 IN5 IN5
n06 n06

4 x 0-20mA

4 x 0-20mA
- Unit - read-only field which displays unit of measurement,

4 x 0-10V
n07 IN6 n07 IN6 n07 IN6
- Mode - defines measurement range, IN7 IN7 IN7
n08 n08 n08
- Low limit - defines measurement level below which in logical n09 IN8 n09 IN8 n09 IN8
channel „Lo” state will be displayed, n10 GND n10 GND n10 GND
- High limit - defines measurement level above which in logical n11 IN9 n11 IN9

4 x 0-20mA
4 x 0-10V
channel „Hi” state will be displayed. n12 IN10 n12 IN10

n13 IN11 n13 IN11

n14 IN12 n14 IN12


Connections for 3 - wire sensor (current) Connections for 3 - wire sensor (voltage) n15 GND n15 GND

UI4 UI4 n16 IN13 n16 IN13


4 current + 4 voltage inputs 4 current + 4 voltage inputs

4 x 0-10V

4 x 0-10V
n01 IN1 n01 IN1 n17 IN14 n17 IN14
4 x 0-20mA
4 x 0-20mA

n02 IN2 n02 IN2


n18 IN15 n18 IN15
n03 IN3 n03 IN3

n04 IN4 n04 IN4


n19 IN16 n19 IN16
1 n05 GND 1 n05 GND

n06 IN5
n06 IN5 n20 GND n20 GND
4 x 0-10V
4 x 0-10V

2 Power supply
(depending on version) Iin1
n07 IN6
2 Power supply n07 IN6
n21 IN17
Iin2 IN7 (depending on version) Uin1 Uin2 IN7
n08 n08

4 x 0-10V
IN8 IN8 n22 IN18
n09 n09
Sensor 1 Sensor 2 GND Sensor 1 Sensor 2 GND
n10 n10 IN19
SERVICE + - + - SERVICE +
+
- +
+
-
n23
n24 IN20
GND GND
3 3 GND
4 +24V DC ±5% (Imax. = 200mA)
4 +24V DC ±5% (Imax. = 200mA) n25
5 digital input 5 digital input
n26 IN21
0/15..24V DC 0/15..24V DC
6 6

4 x 0-10V
GND GND
n27 IN22
7 B- 7 B-
RS-485 RS-485
8 A+ insulated 8 A+ insulated n28 IN23

n29 IN24

TECHNICAL DATA n30 GND

UI4 UI8 UI12

Number of inputs 4 x voltage + 4 x current 8 x voltage + 8 x current 12 x voltage + 12 x current

Measurement range voltage: 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 2 ÷ 10V; voltage: 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 2 ÷ 10V; voltage: 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 2 ÷ 10V;
current: 0 ÷ 20 mA, 4 ÷ 20 mA current: 0 ÷ 20 mA, 4 ÷ 20 mA current: 0 ÷ 20 mA, 4 ÷ 20 mA
Hardware limitation voltage: 0V ÷ 12V; current: 0 mA ÷ 24 mA voltage: 0V ÷ 12V; current: 0 mA ÷ 24 mA voltage: 0V ÷ 12V; current: 0 mA ÷ 24 mA

Hardware resolution voltage: 1 mV; current: 1 µA voltage: 1 mV; current: 1 µA voltage: 1 mV; current: 1 µA

Precision 0.1% @ 25°C 0.1% @ 25°C 0.1% @ 25°C

Internal impedance voltage: 50 kΩ; current: type 100 Ω voltage: 50 kΩ; current: type 100 Ω voltage: 50 kΩ; current: type 100 Ω

Protection voltage: no; voltage: no; voltage: no;


current: 50 mA, auto-reset fuse current: 50 mA, auto-reset fuse current: 50 mA, auto-reset fuse

Sampling period 10 ms, CMC reads modules every 100 ms 10 ms, CMC reads modules every 100 ms 10 ms, CMC reads modules every 100 ms

Weight 32 g 43 g 62 g

Part number M99-UI4-001 M99-UI8-001 M141-UI12-001


*
www.multicon24.eu 10
MultiCon CMC I/O modules
Input modules - voltage/current/NTC

UI4N8: 4 voltage + 4 current + 8 NTC inputs


UI8N8: 8 voltage + 8 current + 8 NTC inputs

The MultiCon UIN modules include 16 or 24 voltage / current / NTC inputs,


which allows to measure current, voltage, resistance and temperature (using
NTC sensors). Inputs are gathered into groups to make connections easier. All
ground terminals of a particular module are common, but separated from
power supply and other modules. If it is necessary to make measurements
with different ground potentials, several UIN modules have to be installed
into MultiCon unit.

MODULE PIN ASSIGNMENT

UI4N8 UI8N8
4 voltage + 4 current 8 voltage + 8 current
Voltage / current / NTC (temperature or resistance measurement) + 8 NTC inputs + 8 NTC inputs
inputs parameters are:
- Name - read-only input name given by the device („mA”, „V”, „°C” n01 IN1

4 x 0 - 100kΩ
n01 IN1

4 x 0 - 100kΩ
or „Ω”), n02 IN2 n02 IN2
- Unit - read-only field which displays unit of measurement, n03 IN3 n03 IN3

- Mode - defines measurement range, n04 IN4 n04 IN4

- Low limit - defines measurement level below which in logical n05 GND n05 GND

channel „Lo” state will be displayed, n06 IN5

4 x 0 - 100kΩ
n06 IN5

4 x 0 - 100kΩ
- High limit - defines measurement level above which in logical n07 IN6 n07 IN6

channel „Hi” state will be displayed. n08 IN7 n08 IN7

n09 IN8 n09 IN8

n10 GND n10 GND


Additionally for temperature mode:
n11 IN9 n11 IN9
NTC Equation - allows to choose method of entering thermistor

4 x 0-20mA
4 x 0-20mA

n12 IN10 n12 IN10


characteristic. There are two possibilities: equation with Beta
n13 IN11 n13 IN11
parameter and equation based on Steinhart-Hart coefficients. n14 IN12
n14 IN12
n15 GND n15 GND

When NTC inputs are used, it is n16 IN13 n16 IN13

4 x 0-20mA
recommended to use shielded
4 x 0-10V

n17 IN14 n17 IN14


wires and connect shield to GND n18 IN15
connector on the module. n18 IN15
n19 IN16 n19 IN16
TECHNICAL DATA n20 GND n20 GND

n21 IN17
n22 IN18 4 x 0-10V
UI4N8 UI8N8 n23 IN19

Number of inputs 4 x voltage + 4 x current + 8 x resistance NTC 8 x voltage + 8 x current + 8 x resistance NTC n24 IN20
n25 GND
Measurement range voltage inputs: 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 2 ÷ 10V voltage inputs: 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 2 ÷ 10V n26 IN21
current inputs: 0 ÷ 20 mA, 4 ÷ 20 mA current inputs: 0 ÷ 20 mA, 4 ÷ 20 mA
4 x 0-10V

n27 IN22
resistance inputs: 0 ÷ 100 kΩ resistance inputs: 0 ÷ 100 kΩ
Hardware limitation voltage: 0 ÷ 12V; current: 0 ÷ 24mA; resistance: 0 ÷ 110kΩ voltage: 0 ÷ 12V; current: 0 ÷ 24mA; resistance: 0 ÷ 110kΩ n28 IN23
n29 IN24
Hardware resolution voltage: 1 mV; current: 1 µA; resistance: 4 Ω voltage: 1 mV; current: 1 µA; resistance: 4 Ω n30 GND

Temp. stability 50 ppm/˚C 50 ppm/˚C

Precision 0,1% @ 25°C 0,1% @ 25°C

Internal impedance voltage: 61 kΩ; current: 100 Ω; resistance: 121 kΩ voltage: 61 kΩ; current: 100 Ω; resistance: 121 kΩ

Protection voltage/NTC: protection resistor voltage/NTC: protection resistor


current: 50 mA, auto-reset fuse current: 50 mA, auto-reset fuse

Sampling period 100 ms 100 ms

Weight 43 g 62 g

Part number M99-UI4N8-001 M141-UI8N8-001

www.multicon24.eu 11
MultiCon CMC I/O modules
Input modules - voltage/current/digital

UI4D8: 4 voltage + 4 current + 8 digital inputs


UI8D8: 8 voltage + 8 current + 8 digital inputs

The MultiCon UID modules include 16 or 24 voltage / current / digital inputs,


which allows to measure current and voltage and can be equipped with
uninsulated digital inputs. Inputs are gathered into groups to make
connections easier. All ground terminals of a particular module are common,
but separated from power supply and other modules. If it is necessary to
make measurements with different ground potentials, several UID modules
have to be installed into MultiCon unit.

MODULE PIN ASSIGNMENT

UI4D8 UI8D8
4 voltage + 4 current 8 voltage + 8 current
Voltage / current inputs parameters are: + 8 digital inputs + 8 digital inputs
- Name - read-only input name given by the device,
- Unit - read-only field which displays unit of measurement („mA”, „V”), n01 IN1 n01 IN1

4 x 0-20mA
4 x 0-20mA
- Mode - defines measurement range, n02 IN2 n02 IN2

- Low limit - defines measurement level below which in logical channel n03 IN3 n03 IN3

„Lo” state will be displayed, n04 IN4 n04 IN4

n05 GND n05 GND


- High limit - defines measurement level above which in logical channel
n06 IN5 n06 IN5
„Hi” state will be displayed.

4 x 0-20mA
4 x 0-10V
n07 IN6 n07 IN6

n08 IN7 n08 IN7


Digital inputs parameters are: n09 IN8
n09 IN8
- Mode - defines input voltage ranges (TTL: „0" for 0 ÷ 0,8V; „1" for 2 ÷ n10 GND
n10 GND
5.5V and HTL: „0" for 0÷4,2V; „1" for 11,5÷30V), n11 IN9
n11 IN9
- Filter time - defines minimal time that has to elapse from last input

4 x 0-10V
n12 IN10 n12 IN10
state change, if this change wants to be noticed. Each input has the n13 IN11
IN17
n13 IN11
possibility to sets its own Filter time, even if this input is part of n14 IN12 n14 IN12
another, different set of this parameter do not disturbs their work. n15 COM 9-12 n15 GND

n16 IN13 n16 IN13

4 x 0-10V
n17 IN14 n17 IN14
IN18
n18 IN15 n18 IN15

n19 IN16 n19 IN16


n20 GND
TECHNICAL DATA n20 COM 13-16
n21 IN17
n22 IN18 IN25
UI4D8 UI8D8
n23 IN19

Number of inputs 4 x voltage + 4 x current + 8 x digital 8 x voltage + 8 x current + 8 x digital n24 IN20
n25 COM 17-20
Measurement range voltage inputs: 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 2 ÷ 10V voltage inputs: 0 ÷ 5V, 1 ÷ 5V, 0 ÷ 10V, 2 ÷ 10V
n26 IN21
current inputs: 0 ÷ 20 mA, 4 ÷ 20 mA current inputs: 0 ÷ 20 mA, 4 ÷ 20 mA
n27 IN22
IN26

digital inputs: TTL: Lo: 0 ÷ 0,8V, Hi: 2 ÷ 5,5V digital inputs: TTL: Lo: 0 ÷ 0,8V, Hi: 2 ÷ 5,5V
HTL: Lo: 0 ÷ 4,2V, Hi: 11,5 ÷ 30V HTL: Lo: 0 ÷ 4,2V, Hi: 11,5 ÷ 30V n28 IN23
Hardware limitation voltage: 0 ÷ 12V; current: 0 ÷ 24mA; digital: 0 ÷ 32V voltage: 0 ÷ 12V; current: 0 ÷ 24mA; digital: 0 ÷ 32V n29 IN24
n30 COM 21-24
Hardware resolution voltage: 1 mV; current: 1 µA voltage: 1 mV; current: 1 µA

Temp. stability 50 ppm/˚C 50 ppm/˚C

Precision 0,1% @ 25°C (voltage/current), 2% @ 25°C (digital) 0,1% @ 25°C (voltage/current), 2% @ 25°C (digital)

Internal impedance voltage: 61 kΩ; current: 100 Ω; digital: 80 kΩ voltage: 61 kΩ; current: 100 Ω; digital: 80 kΩ

Protection voltage/digital: protection resistor voltage/digital: protection resistor


current: 50 mA, auto-reset fuse current: 50 mA, auto-reset fuse

Sampling period 100 ms 100 ms

Weight 43 g 62 g

Part number M99-UI4D8-001 M141-UI8D8-001

www.multicon24.eu 12
MultiCon CMC I/O modules
Input modules - thermocouple

TC4: 4 thermocouple inputs


TC8: 8 thermocouple inputs
TC12: 12 thermocouple inputs
The range of TC modules consist of 4, 8 and 12 thermocouple input modules,
each equipped with 1 input for connectors temperature measurement.
Primary destination of these modules is temperature measurement using
thermocouple sensors, but it is also possible to measure voltage with typical
thermocouple ranges.

TC8 MODULE PIN ASSIGNMENT

TC4 TC8 TC12


4 thermocouple 8 thermocouple 12 thermocouple
inputs inputs inputs
TC4 n01 - n01 - n01 -
IN1 IN1 IN1
n02 + n02 + n02 +
n03
- - -
TC modules parameters are: IN2 n03 IN2 n03 IN2
- Name - read-only input name given by the device, n04 + n04 + n04 +

- Unit - read-only field which displays „°C” or „mV”, depending on Mode n05 - n05 - n05 -
IN3 IN3 IN3
n06 + n06 + n06 +
parameter settings, - - -
n07 n07 n07
- Mode - allows to set type of thermocouple or mV measurement range, IN4 IN4 IN4
n08 + n08 + n08 +
- Low limit - defines measurement level below which in logical channel -
n09 IN5
„Lo” state will be displayed,

IN_T

IN_T
+
n10
- High limit - defines measurement level above which in logical channel n11
-
- IN6
„Hi” state will be displayed, n09 n12 +
IN5
- Wire compensation - allows to compensate measurement errors, n10 +
-

IN_T
which can be caused by wrong sensor readings, n11 IN6
- Compensation - parameter which allows to manually compensate n12 +
sensor error, written here value is added or subtracted from measured n13 - n13 -
IN7 IN7
sensor value, n14 + n14 +
n15
- n15
-
- Actual temperature - parameter in which user enters actual IN8 IN8
n16 + n16 +
temperature near the sensor, which is measured by a more reliable
thermometer, n17 -
IN9
n18 +
- Compensate - button which activates the compensation, -
Pin description: n19 IN10
- Compensation - read only parameter; displays voltage value calculated
IN_T : Cold Junction n20 +
to compensate temperature measurement. temperature sensor n21 -
IN11
n22 +
n23
-
TECHNICAL DATA n24 +
IN12

TC4 TC8 TC12

Number of inputs 4 8 12

Measurement range thermocouple J, K, S, T, N, R, B, E (PN-EN), thermocouple J, K, S, T, N, R, B, E (PN-EN), thermocouple J, K, S, T, N, R, B, E (PN-EN),


L (GOST); voltage: -10 ÷ 25 mV, ±25 mV, L (GOST); voltage: -10 ÷ 25 mV, ±25 mV, L (GOST); voltage: -10 ÷ 25 mV, ±25 mV,
-10 ÷ 100 mV, ±100 mV -10 ÷ 100 mV, ±100 mV -10 ÷ 100 mV, ±100 mV
Hardware limitation -30 mV ÷ 30 mV, -120 mV ÷ 120 mV -30 mV ÷ 30 mV, -120 mV ÷ 120 mV -30 mV ÷ 30 mV, -120 mV ÷ 120 mV

Hardware resolution 1 µV (± 30 mV), 4 µV (± 120 mV) 1 µV (± 30 mV), 4 µV (± 120 mV) 1 µV (± 30 mV), 4 µV (± 120 mV)

Voltage precision 0,1% @ 25°C 0,1% @ 25°C 0,1% @ 25°C

Permissible long time overload 20% 20% 20%

Permissible voltage difference 0.5 V between channels 0.5 V between channels 0.5 V between channels

Input impedance typ. 1 MΩ typ. 1 MΩ typ. 1 MΩ

Sampling period 385 ms * 385 ms * 385 ms *

Weight 32 g 42 g 52 g

Part number M99-TC4-001 M99-TC8-001 M141-TC12-001

* CMC reads data from modules every 100 ms

www.multicon24.eu 13
MultiCon CMC I/O modules
Input modules - RTD

RT4: 4 RTD inputs


RT6: 6 RTD inputs

The range of RTD modules consist of 4 and 6 RTD input modules. These
inputs are used for temperature measurement using RTD type temperature
sensors (by 2-, 3- and 4-wire method), or for resistance measurement in the
ranges up to 3kΩ. The RT modules cooperate with many kinds of resistance
thermometers and thanks to this, there is no need to change the module
when another temperature sensor has been used, the user only needs to
change the settings in the MultiCon unit.

MODULE PIN ASSIGNMENT


RT6
RT4 RT6
4 RTD inputs 6 RTD inputs
RT4 n01 n01
n02 n02

IN1
IN1
RT4 and RT6 modules parameters are: n03 n03
- Name - read-only input name given by the device, n04 n04
- Unit - read-only field which displays „°C” when Mode parameter is set on temperature n05 n05
n06 n06

IN2
IN2
measurement, or displays „Ω” when Mode parameter is set on resistance measurement,
n07 n07
- Mode - defines which sensor is used for measurement, or what is the resistance
n08 n08
measurement range and what is the method of these measurements,
n09 n09
- Low limit - defines measurement level below which in logical channel „Lo” state will be
n10 n10

IN3
IN3
displayed, n11
n11
- High limit - defines measurement level above which in logical channel „Hi” state will be n12 n12
displayed. n13 n13
n14 n14

IN4
IN4
Schematic diagram for the RT4 module and MB1 Modbus port n15 n15
n16 n16
Pt100 Slot B
RT4
sensor 4 RTD inputs
n01
n17
n02
n18
IN1

1 Inp.B1 : RTD

IN5
n03
Control system n04

2 Power supply
(depending on version)
n05
n06
RTD 2-wire RTD 3-wire RTD 4-wire n19
IN2

n07 Inp.B2 : RTD

Slave device
n08
configuration configuration configuration n20
Heater SERVICE
n09
n10
IN3

Inp.B3 : RTD
Slave address: 1
Register: 1h
3 GND
n11
n12
n01 n01 n01 n21
4 +24V DC ±5% (Imax. = 200mA)

5 digital input n13


n02 n02 n02 n22
IN1

IN6
0/15..24V DC n14
0÷5A
IN4

6 Inp.B4 : RTD
IN1

IN1

Current 7
GND

B-
n15

GND converter RS-485 8 A+


RS-485
insulated
n16
n03 n03 n03 n24
n04 n04 n04 n25
TECHNICAL DATA

RT4 RT6

Number of inputs 4 6

Measurement range Pt100, Pt500, Pt1000 (PN-EN); Pt'50, Pt'100, Pt'500 (GOST) Pt100, Pt500, Pt1000 (PN-EN); Pt'50, Pt'100, Pt'500 (GOST)
Ni100, Ni500, Ni1000 (PN-EN) Ni100, Ni500, Ni1000 (PN-EN)
Cu50, Cu100, Cu'50, Cu'100 (PN-83M-53852) Cu50, Cu100, Cu'50, Cu'100 (PN-83M-53852)
resistance: 0 ÷ 300 Ω, 0-3 kΩ resistance: 0 ÷ 300 Ω, 0-3 kΩ

Temperature range -100 ÷ 600°C (Pt100, Pt500, Pt1000) -100 ÷ 600°C (Pt100, Pt500, Pt1000)
-200 ÷ 600°C (Pt'50, Pt'100, Pt'500) -200 ÷ 600°C (Pt'50, Pt'100, Pt'500)
-50 ÷ 200°C (Cu50, Cu100); -200 ÷ 200°C (Cu'50, Cu'100) -50 ÷ 200°C (Cu50, Cu100); -200 ÷ 200°C (Cu'50, Cu'100)
-60 ÷ 180°C (Ni100, Ni500, Ni1000) -60 ÷ 180°C (Ni100, Ni500, Ni1000)

Resistance precision 0,1% @ 25°C 0,1% @ 25°C

Connection method 2, 3 and 4 wire (switched manually) 2, 3 and 4 wire (switched manually)

Sampling period 1s* 1s*

Weight 42 g 57 g

Part number M99-RT4-001 M141-RT6-001

* CMC reads data from modules every 100 ms

www.multicon24.eu 14
MultiCon CMC I/O modules
Input modules - digital

D8: 8 isolated digital inputs


D16: 16 isolated digital inputs
D8 D24: 24 isolated digital inputs

On customer's request, the MultiCon device can be equipped with modules


having 8, 16 or 24 digital inputs. These inputs can be used singly, in groups of
four or all inputs available in the module. The measurement results are
presented in decimal system.

D16
MODULE PIN ASSIGNMENT

D8 D16 D24
8 digital inputs 16 digital inputs 24 digital inputs
n01 IN1 n01 IN1 n01 IN1
n02 IN2 n02 IN2 n02 IN2
IN9 IN17 IN25
D modules parameters are: n03 IN3 n03 IN3 n03 IN3

- Name - read-only input name given by n04 IN4 n04 IN4 n04 IN4
n05 COM 1-4 IN11 n05 COM 1-4 n05 COM 1-4
the device, n06 IN5 n06 IN5 n06 IN5
- Filter time - defines minimal time that has n07 IN6 n07 IN6 n07 IN6
IN10 IN18 IN26
to elapse from last input state change, n08 IN7 n08 IN7 n08 IN7
if this change wants to be noticed. n09 IN8 n09 IN8 n09 IN8
n10 COM 5-8 n10 COM 5-8 IN21 n10 COM 5-8
n11 IN9 n11 IN9
Isolation n12 IN10 n12 IN10
IN19 IN27
R=3k n13 IN11 n13 IN11
IN 1
n14 IN12 n14 IN12
n15 COM 9-12 n15 COM 9-12 IN31
R=3k
IN 2 n16 IN13 n16 IN13
n17 IN14 n17 IN14
R=3k IN20 IN28
IN 3
n18 IN15 n18 IN15
n19 IN16 n19 IN16
R=3k CMC-99/141 n20 COM 13-16 n20 COM 13-16
Interface
IN 4 Main board
n21 IN17
n22 IN18
IN29
COM 1-4
n23 IN19
Internal structure All COMs are isolated n24 IN20
IN 5
of the digital input from each other and
IN 6 module optoisolation n25 COM 17-20
from the device GND
IN 7 n26 IN21
IN 8 n27 IN22
COM 5-8 n28 IN23 IN30
n29 IN24
n30 COM 21-24
TECHNICAL DATA

D8 D16 D24

Number of inputs 8 (2 groups of 4 inputs each, isolated 16 (4 groups of 4 inputs each, isolated 24 (6 groups of 4 inputs each, isolated
from others signals) from others signals) from other signals)

Input signals voltage levels | Uin | < 1V (logical LOW state) | Uin | < 1V (logical LOW state) | Uin | < 1V (logical LOW state)
| Uin | > 4V (logical HIGH state) | Uin | > 4V (logical HIGH state) | Uin | > 4V (logical HIGH state)

Input voltage max. 30V 30V 30V

Input current (typically) 15 mA @24V; 5 mA @10V; 2 mA @5V 15 mA @24V; 5 mA @10V; 2 mA @5V 15 mA @24V; 5 mA @10V; 2 mA @5V

Insulation strength 500V 500V 500V

Sampling frequency 3 kHz * 3 kHz * 3 kHz *

Input signals representation 8 single bits: IN1-IN8; two 4-bit groups: 16 single bits: IN1-IN16; four 4-bit 24 single bits: IN1-IN24; six 4-bit
IN9-IN10; 1 byte: IN11 groups: IN17-IN20; 1 integer: IN21 groups: IN25-IN30; 1 integer: IN31

Weight 30 g 40 g 58 g

Part number M99-D8-001 M99-D16-001 M141-D24-001

* CMC reads state of inputs every 100 ms

www.multicon24.eu 15
MultiCon CMC I/O modules
Input modules - universal counters

CP2: 2 isolated universal counters


CP4: 4 isolated universal counters

The MultiCon can be also equipped with modules having 2 or 4 universal


counters. Each counter can be configured independently and has two
counting inputs (Inp[n]1, Inp[n]2), programmable input (Prog[n]), reset
input (Res[n]), where „n” means counter number from 1 to 4.

MODULE PIN ASSIGNMENT


CP2
CP2 CP4
2 universal counters 4 universal counters

n01 Inp11 n01 Inp11

CP4 n02 Inp12 n02 Inp12


n03 Prg1 Counter 1 n03 Prg1 Counter 1
n04 Res1 n04 Res1
n05 COM1 n05 COM1
The counter parameters are: n06 Inp21 n06 Inp21
- Name - read-only input name given by the device, n07 Inp22 n07 Inp22

-Unit - read-only field which displays measurement unit: pulses, n08 Prg2 Counter 2 n08 Prg2 Counter 2
n09 Res2 n09 Res2
- Low Limit - value determining amount of pulses, below which in n10 COM2 n10 COM2
logical channel „Lo” state will be displayed, n11 Inp31
- High Limit - value determining amount of pulses, above which in n12 Inp32

logical channel „Hi” state will be displayed, n13 Prg3 Counter 3

- Function mode - specifies the counting mode: „A + B”, „A - B”, „quad”, n14 Res3
n15 COM3
- Reset now - button allowing user to manually reset the counter, n16 Inp41
- Reset mode - it allows to choose an additional resets for the counter, n17 Inp42
it has the following parameters: from log. channel or external, n18 Prg4 Counter 4

- Reset source - this parameter is visible when Reset mode is set as n19 Res4
n20 COM4
from log. channel or both, it contains a list of logical channels and the
chosen one will reset the counter when its value is higher than 0, Pin description:
- Prog. inp. mode - specifies counter reaction on higher than 0 value Inp[n]1, Inp[n]2 : counting inputs, pulse
appearance on Prog. input, Prg[n] : programmable inputs
Res[n] : reset inputs
- Filter - sets filter on counter inputs which allows getting rid of
COM[n] : common inputs
negative effects of signal bounces; it has the following parameters: [n] = counter number
disable, 10 ÷ 90.

TECHNICAL DATA

CP2 CP4

Number of inputs 2 counters (2 groups x 4 inputs, every group isolated 4 counters (4 groups x 4 inputs, every group isolated
from the other signals) from the other signals)

CMC counting range -4.515 ÷ 415 pulses -4.515 ÷ 415 pulses


Module hardware limitation -231 ÷ 231 pulses -231 ÷ 231 pulses

Input signals voltage levels | Uin | < 1V (logical LOW state) | Uin | < 1V (logical LOW state)
| Uin | > 10V (logical HIGH state) | Uin | > 10V (logical HIGH state)

Max input voltage 30V 30V

Input current (typically) 14 mA @24V; 6 mA @10V 14 mA @24V; 6 mA @10V

Insulation strength 2 kV 2 kV

Max input frequency 5 kHz* (for quad signals); 10 kHz (for other signals) 5 kHz* (for quad signals); 10 kHz (for other signals)

Protection 50 mA auto-reset fuse 50 mA auto-reset fuse

Weight 35 g 42 g

Part number M99-CP2-001 M99-CP4-001

* CMC reads result every 100 ms

www.multicon24.eu 16
MultiCon CMC I/O modules
Input modules - hourmeters

HM2: 2 isolated hourmeters


HM4: 4 isolated hourmeters

The HM2 and HM4 are the hourmeters modules developed for the MultiCon
units. Allow to measure period of time between START and STOP signals, as
well as sum of periods. These modules are ideal solution to control working
time of a machinery, duration of phenomena or for maintenance purposes.
They have 2 or 4 independent couters. Each counter is equipped with 2
inputs - START/STOP and PRG (programmable), which can be set as
asynchronous RESET, HOLD or used as independent digital input.
HM2

MODULE PIN ASSIGNMENT


HM4 HM2 HM4
2 hourmeters 4 hourmeters

n01 START/STOP 1 n01 START/STOP 1


HM counters parameters are: n02 PRG 1 n02 PRG 1
- Name - read-only input name given by the device, n03 COM 1 n03 COM 1
-Unit - read-only parameter which displays measurement unit: sec.,
- Mode - read-only parameter, displays measured physical quantity: Time, n04 START/STOP 2 n04 START/STOP 2
- Low Limit - value determining time, below which in logical channel „Lo” state n05 PRG 2 n05 PRG 2
will be displayed, n06 COM 2 n06 COM 2
- High Limit - value determining time, above which in logical channel „Hi” state
will be displayed,
n07 START/STOP 3
- Start/Stop inp. trig. - allows to define, when the device should start or stop
n08 PRG 3
counting, options: high level, low level, rising edge, falling edge,
n09 COM 3
- Reset now - button allowing user to manually reset the counter,
- Reset mode - parameter allowing choose an additional resets for the counter,
it has the following options: disable, from log. channel external or both, n10 START/STOP 4
n11 PRG 4
- Reset source - this parameter is visible when Reset mode is set as from log.
n12 COM 4
channel or both, it contains a list of logical channels and the chosen one will
reset the counter when its value is higher than 0,
- Prog. inp. mode - specifies counter reaction on active signal appearance on Pin description:
START/STOP [n] - input which starts and stops
Prog. input, options: binary input, reset, inhibit, time counting,
- Prog. inp. trig. - allows to define when the device should reset or inhibit time PRG [n] : programmable input
counter, options: high level, low level, rising edge, falling edge, COM [n] : common terminal
- Filter - sets filter on counter inputs which allows to getting rid of negative [n] = counter number
effects of signal bounces; it has the following parameters: disable, 10 ÷ 90.

TECHNICAL DATA
HM2 HM4

Number of inputs 2 hourmeters 4 hourmeters

CMC counting range 0 - 109 sec. 0 - 109 sec.

Input signals voltage levels | Uin | < 1V (logical LOW state) | Uin | < 1V (logical LOW state)
| Uin | > 10V (logical HIGH state) | Uin | > 10V (logical HIGH state)

Max input voltage 30V 30V

Input current (typically) 14 mA @24V; 6 mA @10V 14 mA @24V; 6 mA @10V

Insulation strength 2 kV 2 kV

Precision / Temp. stability ±30 ppm @ +25°C / ±50 ppm/K ±30 ppm @ +25°C / ±50 ppm/K

Max input frequency 1 kHz 1 kHz

Protection 50 mA auto-reset fuse 50 mA auto-reset fuse

Weight 28 g 33 g

Part number M99-HM2-001 M99-HM4-001

www.multicon24.eu 17
MultiCon CMC I/O modules
Input modules - analogue flowmeters

FI2: 2 analogue flowmeters + 2 current inputs


FI4: 4 analogue flowmeters + 4 current inputs

The FI modules have been especially designed for the MultiCon units used in
flow measurement applications. They allow user to display and record both
actual flow (rate) and total flow (volume).
These modules have extra 2 or 4 analogue inputs for general purpose use.
Each flow channel is equipped with IN[n] input and common ground GND. All
inputs are galvanically separated from the device, however have common
ground. The user can, thanks to Scaling parameter in Logical channel,
interpret measured current by the device at its discretion, which allows to
cooperate with any kind of analogue output sensors. The general purpose
use current inputs have common ground and they are isolated from the
supply voltage and other modules.

FI2

Analogue flowmeter parameters are: MODULE PIN ASSIGNMENT


- Name - read-only input name given by the device,
- Unit - read-only field which displays measurement unit,
- Base unit - defines unit which is used by the totalizer (for example when flow FI2 FI4
2 flowmeter inputs 4 flowmeter inputs
measurement unit is m3/s, the base unit is „m3”) , + 2 current inputs + 4 current inputs
- Mode - defines current range of selected input (0÷20 mA, 4÷20 mA) and the IN1

(flowmeter)
n01

4 x 0-20mA
IN1 2 x 0-20mA
time base which is used during the measurement, n01
n02 IN2
IN2 (flowmeter)
- Low limit - value which determines measured current, below which in logical n02
n03 IN3
n03 IN3
channel „Lo” state will be displayed, 2 x 0-20mA n04 IN4
n04 IN4
- High limit - value which determines measured current, above which in logical n05 GND
n05 GND
channel „Hi” state will be displayed, IN5

4 x 0-20mA
n06
- Balance - submenu which contains totalizer settings: n07 IN6
ź Reset now - manual reset of the totalizer, IN7
n08
ź Reset mode - turns on and off reset from logical channel, IN8
n09
ź Reset source - allows to choose a logical channel from the list, which will GND
n10
reset the totalizer, when value in this channel will be greater than 0,
ź Strobe mode - turns on and off balance calculating from logical channel,
ź Strobe source - allows to choose logical channel from the list, which will
hold balance calculating in totalizer,
ź Counting direction - turns on and off change of the counting direction,
ź Direction source - allows to choose a logical channel from the list, which
will change the counting direction.

TECHNICAL DATA

FI2 FI4

Number of inputs 2 x analogue flowmeter + 2 x current 4 x analogue flowmeter + 4 x current

Measurement range flow input modes: 0 ÷ 20 mA, 4 ÷ 20 mA flow input modes: 0 ÷ 20 mA, 4 ÷ 20 mA
flow input units: 1/sec, 1/min, 1/h flow input units: 1/sec, 1/min, 1/h
current input: 0 ÷ 20 mA, 4 ÷ 20 mA current input: 0 ÷ 20 mA, 4 ÷ 20 mA
Hardware limitation current: 0 mA ÷ 24 mA current: 0 mA ÷ 24 mA

Hardware resolution current: 1 µA current: 1 µA

Precision 0.1% @ 25°C 0.1% @ 25°C

Internal impedance current: typ. 100 Ω current: typ. 100 Ω

Protection current: 50 mA, auto-reset fuse current: 50 mA, auto-reset fuse

Sampling period 50 ms * 50 ms *

Weight 28 g 33 g

Part number M99-FI2-001 M99-FI4-001


* CMC reads result every 100 ms
www.multicon24.eu 18
MultiCon CMC I/O modules
Input modules - pulse flow or ratemeters

FT2: 2 isolated pulse flow or ratemeters


+ 2 current inputs
FT4: 4 isolated pulse flow or ratemeters
+ 4 current inputs

The FT modules have been especially designed for the MultiCon units used in
flow or rate measurement applications. They allow user to display and record
both actual flow (rate) and total flow (volume). These modules have extra 2
or 4 analogue inputs for general purpose use. Each pulse channel is equipped
with counting inputs: Inp[n]1, Inp[n]2 and common ground COM[n]. All
pulse channels are galvanically separated from the device and from
themselves. The general purpose use current inputs have common ground
and they are isolated from the supply voltage and other modules.
FT4 FT2 and FT4 modules can be used also as high speed quadrature counters.

FT2

Pulse flow or ratemeters parameters are: MODULE PIN ASSIGNMENT


- Name - read-only input name given by the device, FT2 FT 4
- Unit - read-only field which displays the time base of the measurement, 2 pulse inputs 4 pulse inputs
- Base unit - defines unit which is used by the totalizer (for example when flow + 2 current inputs + 4 current inputs
measurement unit is m3/s, the base unit is „m3”) , n01 Inp11 n01 Inp11

- Mode - defines the time base which is used during the measurement (pulses per n02 Inp12 n02 Inp12

second, pulses per minute, pulses per hour), n03 COM1 n03 COM1

- Low limit - value which determines amount of pulses, below which in logical n04 Inp21 n04 Inp21

channel „Lo” state will be displayed, n05 Inp22 n05 Inp22

- High limit - value which determines amount of pulses, above which in logical n06 COM2 n06 COM2

channel „Hi” state will be displayed, n07 Inp31


- Counting mode - defines how the device should interpret signals on pulse inputs, n08 Inp32
it has the following options: with direction input, quad 1, quad 4, n09 COM3
2 x 0-20mA
- Filter - defines maximal frequency (with 50% duty cycle) the device will measure, n07 IN3 n10 Inp41
options: disable, 10 Hz, 25 Hz, 50 Hz, 100 Hz, 1 kHz, 5 kHz, 10 kHz, 50 kHz, IN4 n11 Inp42
n08
- Zero time - maximal awaiting time for the next pulse. If this time is exceeded the n12 COM4
n09 GND
device will display 0 value; it has the following options: 0.1 sec., 1 sec., 10 sec., n13 IN5

4 x 0-20mA
- Balance - submenu which contains totalizer settings: Reset now; Reset mode; Pin description: n14 IN6
Reset source; Strobe mode; Strobe source; Counting direction; Direction source. Inp[n]1, Inp[n]2 : data n15 IN7
inputs for tachometer [n], IN8
n16
COM[n] : COM for
n17 GND
TECHNICAL DATA tachometer [n]

FT2 FT4

Number of inputs 2 x pulse flow or ratemeters (isolated) + 2 x current 4 x pulse flow or ratemeters (isolated) + 4 x current

Measurement range flow / tacho input units: 1/sec, 1/min, 1/h flow / tacho input units: 1/sec, 1/min, 1/h
current input: 0 ÷ 20 mA, 4 ÷ 20 mA current input: 0 ÷ 20 mA, 4 ÷ 20 mA
Hardware limitation current: 0 mA ÷ 24 mA current: 0 mA ÷ 24 mA

Hardware resolution current: 1 µA current: 1 µA

Precision 0.1% @ 25°C 0.1% @ 25°C

Internal impedance current: typ. 100 Ω current: typ. 100 Ω

Max input frequency flow / tacho: 50 kHz flow / tacho: 50 kHz

Protection current: 50 mA, auto-reset fuse current: 50 mA, auto-reset fuse

Sampling period 50 ms * 50 ms *

Weight 42 g 50 g

Part number M99-FT2-001 M99-FT4-001


* CMC reads result every 100 ms

www.multicon24.eu 19
MultiCon CMC I/O modules
Output modules - current

IO2: 2 current outputs, isolated, passive


IO4: 4 current outputs, isolated, passive
IO6: 6 current outputs, isolated, passive
IO8: 8 current outputs, isolated, passive
Current output modules are used to control other devices based on current
in industrial automation applications. These modules are equipped with 2, 4,
6, 8 individually isolated (one from another) passive current outputs.

MODULE PIN ASSIGNMENT

IO2 IO4 IO6 IO8


2 current outputs 4 current outputs 6 current outputs 8 current outputs

IO8 n01 n01 n01

Passive

Passive
Passive
OUT 4 OUT 6 OUT 8
n02 n02 n02
IO2
Current outputs parameters are:
- Name - read-only output name given by the device,
n03 n03 n03

Passive

Passive
- Unit - current outputs have constant unit, „mA”,

Passive
OUT 3 OUT 5 OUT 7
n04 n04 n04
- Source - contains a logical channels list, where selected
one will be data source for current output,
- Lower and Upper level (Input levels parameter block) -
limits input signal range which is downloaded from Source n05 n05
Passive

n05 n05

Passive

Passive
Passive
OUT 2 OUT 2 OUT 4 OUT6
parameter, below this range the input signal will be equal n06 n06 n06 n06
to Lower level and above this range the input signal will
be equal to Upper level,
- Lower and Upper level (Output levels parameter block) - n07 n07 n07 n07
Passive
Passive

Passive

Passive
defines output signal changes range, below this range the n08
OUT 1
n08
OUT 1
n08
OUT 3
n08
OUT 5

output signal will be equal to Lower level and above this


range output will be equal to Upper level. The
relationship between input and output levels is linear and
limited by defined range, n09 Passive n09

Passive
OUT 2 OUT 4
- Alarm level - defines output value which appears when n10 n10

Source parameter returns alarm state, but it can not


exceeds the hardware limit. Alarm state is when a logical
channel which is data source returns Err, Lo or Hi state. n11 n11
Passive

Passive
OUT 1 OUT 3
n12 n12
TECHNICAL DATA

IO2 IO4 IO6 IO8


n13
Passive

Number of outputs 2 (passive) 4 (passive) 6 (passive) 8 (passive) OUT 2


n14
Nominal analogue range 4 ÷ 20 mA * 4 ÷ 20 mA * 4 ÷ 20 mA * 4 ÷ 20 mA *

Hardware output limitation 3 ÷ 25 mA 3 ÷ 25 mA 3 ÷ 25 mA 3 ÷ 25 mA


n15
Passive

Output voltage dropout max. 9V max. 9V max. 9V max. 9V n16


OUT 1

Loop supply range 9 ÷ 30V 9 ÷ 30V 9 ÷ 30V 9 ÷ 30V

Overload protection Internal resettable fuse Internal resettable fuse Internal resettable fuse Internal resettable fuse
50 mA 50 mA 50 mA 50 mA

Output current precision 0.1% @25°C, 50 ppm/°C 0.1% @25°C, 50 ppm/°C 0.1% @25°C, 50 ppm/°C 0.1% @25°C, 50 ppm/°C

Resolution 12 bit 12 bit 12 bit 12 bit

Insulation strength 1 min @ 500V AC 1 min @ 500V AC 1 min @ 500V AC 1 min @ 500V AC

Weight 23 g 30 g 38 g 53 g

Part number M99-IO2-001 M99-IO4-001 M141-IO6-001 M141-IO8-001


* CMC updates output value every 100 ms

www.multicon24.eu 20
MultiCon CMC I/O modules
Output modules - SSR

S8: 8 x SSR outputs


S16: 16 x SSR outputs
S24: 24 x SSR outputs
These modules are equipped with 8, 16 or 24 SSR outputs. May be used to
control executive device state in a simple on/off or PWM mode.

MODULE PIN ASSIGNMENT


S8 S16 S24
8 SSR outputs 16 SSR outputs 24 SSR outputs
+10..24V DC +10..24V DC +10..24V DC
S16 n01 n01 n01
n02 OUT1 n02 OUT1 n02 OUT1
n03 OUT2 n03 OUT2 n03 OUT2
n04 OUT3 n04 OUT3 n04 OUT3
S8 n05 OUT4 n05 OUT4 n05 OUT4

n06 OUT5 n06 OUT5 n06 OUT5

Built-in outputs parameters in the PWM mode are: n07 OUT6 n07 OUT6 n07 OUT6

- Name - read-only output name given by the device, n08 OUT7 n08 OUT7 n08 OUT7

- Mode - this parameter allows the user to select method of the output operation, n09 OUT8 n09 OUT8 n09 OUT8

- Source - it contains the Logical channels list, the chosen one will be data source n10 GND n10 GND n10 GND

n11 +10..24V DC n11 +10..24V DC


for the relay,
- Alarm level - allows the user to enter value at the output in times of alarm state, n12 OUT9 n12 OUT9

- Level - defines the source signal level at which the output switches the state n13 OUT10 n13 OUT10
n14 OUT11 n14 OUT11
(from low to high state or vice versa from high to low state), occurs for the
n15 OUT12 n15 OUT12
mode,
n16 OUT13 n16 OUT13
- Lower level and Upper level - defines constant values on which depends relay
n17 OUT14 n17 OUT14
state switch (for Level mode: value), or allows to choose a logical channels from
n18 OUT15 n18 OUT15
the list, which actual value will be data for relay state switch (for Level mode: n19 OUT16 n19 OUT16
channel), n20 GND n20 GND
- Hysteresis - shifts relay levels with constant value, in the Relay operation mode, n21 +10..24V DC
- On delay - time which elapses from the moment when source data meets the Pin description: n22 OUT9
requirements for relay switch, to actual relay's switch to active state, 1, 11, 21 : supply inputs for outputs n23 OUT10
- OFF delay - time which elapses from the moment when source data meets the 1-8, 9-16 and 17-24 respectively (10- n24 OUT11
24V, max. 500 mA).
requirement for relay switch, to actual relay's switch to passive state, n25 OUT12
10, 20, 30 : GND for outputs 1-8, 9-16
- Min.ON time - minimal time when the relay is in the active state, and 17-24 (internally connected) n26 OUT13
- Min.OFF time - minimal time when the relay is in the passive state. 2-9, 12-19, 21, 29 : SSR driver outputs n27 OUT14
n28 OUT15
n29 OUT16
TECHNICAL DATA n30 GND

S8 S16 S24

Number of outputs 8 16 (in 2 groups with separate supply) 24 (in 3 groups with separate supply)

Max. current source powered internally: 10 mA, sum limited to powered internally: 10 mA, sum limited to powered internally: 10 mA, sum limited to
per output 50 mA, powered externally: 100 mA, sum 50 mA for a group, powered externally: 50 mA for a group, powered externally:
limited to 500 mA 100 mA, sum limited to 500 mA for a group 100 mA, sum limited to 500 mA for a group

Output method relay modes or PWM mode * relay modes or PWM mode * relay modes or PWM mode *

Output High Level powered internally: ≥8V powered internally: ≥8V powered internally: ≥8V
voltage powered externally: ≥(Vext. - 0.5V) powered externally: ≥(Vext. - 0.5V) powered externally: ≥(Vext. - 0.5V)

Overload protection powered internally: internal fuse 50 mA, powered internally: internal fuse 50 mA powered internally: internal fuse 50 mA
powered externally: internal fuse 500 mA (per group), powered externally: internal (per group), powered externally: internal
fuse 500 mA (per group) fuse 500 mA (per group)

External output supply 30 V max. 30 V max. 30 V max.

Insulation strength 1 min @ 500V AC 1 min @ 500V AC 1 min @ 500V AC

Weight 32 g 42 g 69 g

Part number M99-S8-001 M99-S16-001 M141-S24-001


* CMC updates output state every 100 ms
www.multicon24.eu 21
MultiCon CMC I/O modules
Output modules - relay

R45: 4 x 5A/250V relay outputs


R65: 6 x 5A/250V relay outputs
R81: 8 x 1A/250V relay outputs
R121: 12 x 1A/250V relay outputs

The modules with relay outputs are used to switch on and off executive
device circuits in the automatics. These modules are equipped with 4, 6, 8 or
12 relay outputs.

R81
MODULE PIN ASSIGNMENT

R45 R65 R81 R121


4 x 5A/250V 6 x 5A/250V 8 x 1A/250V 12 x 1A/250V
relay outputs relay outputs relay outputs relay outputs
n01 n01 n01 n01
R45 OUT1 OUT1
n02 n02 n02 n02
OUT1 OUT1
Relay parameters are: n03 n03 n03 n03
OUT2 OUT2
- Name - read-only output name given by the device,
n04 n04 n04 n04
- Mode - read-only field which allows to choose, how the relay
reacts on the source signal (Source parameter), n05 n05 n05 n05
OUT2 OUT3 OUT3
- Source - it contains the Logical channels list, the chosen one will OUT2
n06 n06 n06
be data source for the relay, n06
- Alarm state - allows to choose relay's respond for alarm state. n07 n07 n07
OUT4 n07
Alarm state is when in logical channel, which is data source for OUT4
n08 n08 n08
the relay, returns -Err-, -Lo- or -Hi-, OUT3 n08
OUT3 OUT5
- Level mode - allows to choose, where the data is coming from for n09 n09 n09
OUT6 n09 OUT5
Level, Lower level and Upper level parameter: value, channel, n10 n10 n10
- Level - defines constant signal level, exceeding which causes relay n10
n11 n11 n11
state switch, or allows to choose a Logical channel, which actual n11
OUT4 OUT6
value data is for relay state switch Level, OUT4 n12 OUT7
n12 n12
- Lower level and Upper level - defines constant values which OUT8 n12
n13 n13
depends on relay state switch, or allows to choose a logical
n13 OUT7
channels from the list, which actual value data is for relay state n14 n14
OUT5 n14 OUT8
switch,
n15
- Hysteresis - shifts relay levels with constant value, n15
- On delay - time which elapses from the moment when source n16
data meets the requirements for relay switch, n16 OUT9
n17
- OFF delay - time which elapses from the moment when source OUT6 OUT10
n17
data meets the requirement for relay switch, n18
- Min.ON time - minimal time when the relay is in the active state, n18
- Min.OFF time - minimal time when the relay is in the passive
n19 OUT11
state.
n20 OUT12

TECHNICAL DATA n21

R45 R65 R81 R121

Number of relays 4 SPDP (Switchable) 6 SPDP (Switchable) 8 SPST (N.O.) 12 SPST (N.O.)

Max. load per relay 5A, cos φ = 1 (resistive load) 5A, cos φ = 1 (resistive load) 1A, cos φ = 1 (resistive load) 1A, cos φ = 1 (resistive load)

Output operation method * disabled, above level, below disabled, above level, below disabled, above level, below disabled, above level, below
level, inside range, outside level, inside range, outside level, inside range, outside level, inside range, outside
range range range range

Max. voltage switched by relay 250V AC 250V AC 250V AC 250V AC

Insulation strength ≤1000V AC @ 60 sec. ≤1000V AC @ 60 sec. ≤1000V AC @ 60 sec. ≤1000V AC @ 60 sec.

Weight 94 g 133 g 74 g 110 g

Part number M99-R45-001 M141-R65-001 M99-R81-001 M141-R121-001

* CMC updates output state every 100 ms

www.multicon24.eu 22
MultiCon CMC I/O modules
Communication modules

ETU: Ethernet + USB


ACM: advanced communication module
USB Host

ETU communication module contains:


- Ethernet port, used for connection of the MultiCon with another
devices or systems via LAN or WAN,
- USB port, used for connection of the external devices such as PC mouse,
keyboard or USB flash drive.

ETU Advanced communication module (ACM) contains:


- Ethernet port, used for connection of the MultiCon with another
ACM devices or systems via LAN or WAN,
- USB port, used for connection of the external devices such as PC mouse,
MODULE PIN ASSIGNMENT keyboard or USB flash drive,
- additional RS-485 port and RS-232 port shared with third RS-485 port,
Pin description: used for communication with other devices using Modbus RTU protocol.
RS-485 (2)

9 GND 9: ground for RS-485


USB (back - host only)
isolated

10 B- 10, 11 : data inputs for RS-485


12 : ground for RS-232 Port used for connection of the external devices such as PC mouse,
11 A+
13 ÷ 19 : data inputs compatible keyboard or USB flash drive.
12 GND
with RS-232 standard
RS-232 + RS-485 (3)

13 B-
14 A+
15 GND Slot D- ACM module

RS-485 (2)
9 GND GND
16 RxD Port MB2 10 B- B- MASTER/
SLAVE
SLAVE
17 TxD 11 A+ A+ device
device

Port MB3
12 GND
13 B-

RS-232 + RS-485 (3)


isolated

18 CTS
1 14 A+
19 RTS 15 GND
2 Power supply
(depending on version)
16 RxD
17 TxD
18 CTS
19 RTS
SERVICE
USB
USB
host
3 GND host
Port MB1 4 +24V DC ±5% (Imax. = 200mA) Port MB4
5 digital input
0/15..24V DC
RJ-45 MASTER
MASTER/
GND
6 GND
ETH device
RJ-45 available in standard SLAVE
B-
7 B-
RS-485
ETH
device A+
8 A+ insulated

Multicon is SLAVE device for this network


Multicon is disabled for this network
Multicon is SLAVE device for this network
Multicon is MASTER device for this network
TECHNICAL DATA

ETU ACM USB (back)

Number of inputs/outputs 2 4 1

Input/output type USB Host, RJ-45 ETH RS-485, RS-232+RS-485, USB Host, RJ-45 ETH USB host

Hardware output limitation USB host: max current output 100 mA USB host: max current output 100 mA current output 100 mA max.

Baudrate RJ-45 ETH: 10 Mb/sec. RS-485 [bit./sec.]: 1200, 2400, 4800, 9600, 19200, 12 Mb/sec.
USB host: 12 Mb/sec. 38400, 57600, 115200
RJ-45 ETH: 10 Mb/sec.
USB host: 12 Mb/sec.

Data format - RS-232/485: 8N1, 8N2, 8E1, 8E2, 8O1, 8O2 -

Immunity level for RJ 45 Burst (5/50ns, 5kHz): 1,5kV / 10 min Burst (5/50ns, 5kHz): 1,5kV / 10 min (± polarization)
(± polarization)

Weight 49 g 66 g 37 g

Part number M99-ETU-002 M99-ACM-002 M99-USB-001

www.multicon24.eu 23
www.multicon24.eu

BRMIOEN_v1.22.071

www.multicon24.eu

You might also like