You are on page 1of 7

CASTILLO PROJECT : 2500 TERESINA DR PAGE :

DESIGN BY :
ENGINEERING JOB NO. : 23-557 DATE : 08/10/23 REVIEW BY :
Wind Analysis for Low-rise Building, Based on ASCE 7-16 / IBC 2015 / CBC 2022

INPUT DATA
Exposure category (B, C or D) B
Importance factor I = 1.00 Category II
Basic wind speed V = 110 mph
Topographic factor Kzt = 1 Flat
Building height to eave he = 10.00
Building height to ridge hr = 19.42 ft
Building length L = 72.00 ft
Building width B = 54.42 ft
Effective area of components A = 33.33 ft2

DESIGN SUMMARY
Max horizontal force normal to building length, L, face = 13.98 kips X 0.6= 8.39 kips (ASD)
Max horizontal force normal to building length, B, face = 11.01 kips X 0.6= 6.61 kips (ASD)
Max total horizontal torsional load = 103 ft-kips
Max total upward force = 58.21 kips

ANALYSIS
Velocity pressure
qh = 0.00256 Kh Kzt Kd V2 I = 18.43 psf
where: qh = velocity pressure at mean roof height, h.
Kh = velocity pressure exposure coefficient evaluated at height, h, = 0.70
Kd = wind directionality factor = 0.85
h = mean roof height = 14.71 ft
< 60 ft, [Satisfactory]
Design pressures for MWFRS
p = qh [(G Cpf )-(G Cpi )]
where: p = pressure in appropriate zone
G Cp f = product of gust effect factor and external pressure coefficient
G Cp i = product of gust effect factor and internal pressure coefficient
= 0.18 or -0.18
a = width of edge strips, MAX[ MIN(0.1B, 0.4h), 0.04B,3] = 5.44 ft

Net Pressures (psf), Basic Load Cases Net Pressures (psf), Torsional Load Cases
Roof angle q = 19.10 Roof angle q = 0.00 Roof angle q = 19.10
Surface Net Pressure with Net Pressure with Surface Net Pressure with
G Cp f G Cp f G Cp f
(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )
1 0.52 6.31 12.94 0.40 4.05 10.69 1T 0.52 1.58 3.24
2 -0.69 -16.03 -9.40 -0.69 -16.03 -9.40 2T -0.69 -4.01 -2.35
3 -0.47 -12.04 -5.41 -0.37 -10.14 -3.50 3T -0.47 -3.01 -1.35
4 -0.42 -11.09 -4.45 -0.29 -8.66 -2.03 4T -0.42 -2.77 -1.11
1E 0.79 11.22 17.85 0.61 7.93 14.56 Roof angle q = 0.00
2E -1.07 -23.04 -16.40 -1.07 -23.04 -16.40 Surface Net Pressure with
G Cp f
3E -0.68 -15.86 -9.22 -0.53 -13.09 -6.45 (+GCp i ) (-GCp i )
4E -0.63 -14.88 -8.24 -0.43 -11.24 -4.61 1T 0.40 1.01 2.67
5 -0.45 -11.61 -4.98 -0.45 -11.61 -4.98 2T -0.69 -4.01 -2.35
6 -0.45 -11.61 -4.98 -0.45 -11.61 -4.98 3T -0.37 -2.53 -0.88
4T -0.29 -2.17 -0.51
Basic Load Cases in Transverse Direction Basic Load Cases in Longitudinal Direction
Area Pressure (k) with Area Pressure (k) with
Surface Surface
(ft2) (+GCp i ) (-GCp i ) (ft2) (+GCp i ) (-GCp i )
1 611 3.85 7.91 1 671 2.72 7.17
2 1760 -28.22 -16.54 2 1659 -26.59 -15.59
3 1760 -21.19 -9.52 3 1659 -16.81 -5.81
4 611 -6.78 -2.72 4 671 -5.81 -1.36
1E 109 1.22 1.94 1E 129 1.03 1.88
2E 313 -7.22 -5.14 2E 415 -9.55 -6.80
3E 313 -4.97 -2.89 3E 415 -5.43 -2.67
4E 109 -1.62 -0.90 4E 129 -1.45 -0.60
Horiz. 10.44 10.44 Horiz. 11.01 11.01
S S
Vert. -58.21 -32.21 Vert. -55.17 -29.18
10 psf min. Horiz. 13.98 13.98 10 psf min. Horiz. 8.01 8.01
Sec. 6.1.4.1 Vert. -39.18 -39.18 Sec. 6.1.4.1 Vert. -39.18 -39.18

Torsional Load Cases in Transverse Direction Torsional Load Cases in Longitudinal Direction
Area Pressure (k) with Torsion (ft-k) Area Pressure (k) with Torsion (ft-k)
Surface Surface
(ft2) (+GCp i ) (-GCp i ) (+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )
(ft2) (+GCp i ) (-GCp i )
1 251 1.58 3.25 24 50 1 271 1.10 2.90 8 22
2 723 -11.60 -6.80 -58 -34 2 1244 -19.95 -11.69 117 69
3 723 -8.71 -3.91 44 20 3 1244 -12.61 -4.36 -74 -26
4 251 -2.78 -1.12 43 17 4 271 -2.35 -0.55 18 4
1E 109 1.22 1.94 37 59 1E 129 1.03 1.88 22 40
2E 313 -7.22 -5.14 -72 -51 2E 415 -9.55 -6.80 56 40
3E 313 -4.97 -2.89 50 29 3E 415 -5.43 -2.67 -32 -16
4E 109 -1.62 -0.90 49 27 4E 129 -1.45 -0.60 31 13
1T 360 0.57 1.16 -10 -21 1T 400 0.41 1.07 -5 -13
2T 1037 -4.16 -2.44 24 14 2T 1659 -6.65 -3.90 -78 -46
3T 1037 -3.12 -1.40 -18 -8 3T 1659 -4.20 -1.45 50 17
4T 360 -1.00 -0.40 -18 -7 4T 400 -0.87 -0.20 -11 -2
Total Horiz. Torsional Load, MT 95 95 Total Horiz. Torsional Load, MT 103.0 103.0

Design pressures for components and cladding


p = qh[ (G Cp) - (G Cpi)]
where: p = pressure on component
pmin = 10 psf (Sec. 6.1.4.2, pg 21)
G Cp = external pressure coefficient.
see table below

Effective Zone 1 Zone 2 Zone 3 Zone 4 Zone 5


Area (ft2) GCP - GCP GCP - GCP GCP - GCP GCP - GCP GCP - GCP
Comp. 33.333333 0.40 -0.85 0.40 -1.44 0.40 -2.29 0.91 -1.01 0.91 -1.22

Comp. & Cladding Zone 1 Zone 2 Zone 3 Zone 4 Zone 5


Pressure Positive Negative Positive Negative Positive Negative Positive Negative Positive Negative
( psf ) 10.61 -18.94 10.61 -29.83 10.61 -45.46 20.05 -21.89 20.05 -25.72
CASTILLO PROJECT : 3334 PINE AVE PAGE :
CLIENT : DESIGN BY :
ENGINEERING JOB NO. : 22-547 DATE : REVIEW BY :
Wind Analysis for Building with h > 60 ft, Based on ASCE 7-05 / IBC 2006 / CBC 2007

INPUT DATA
Exposure category (B, C or D) B
Importance factor (0.87, 1.0 or 1.15) I = 1.00 Category II, page 77
Basic wind speed (IBC Tab 1609.3.1V3S) V = 110 mph
Topographic factor (Sec.6.5.7.2) Kzt = 1 Flat, page 26 & 45
Building height to roof H = 9 ft
Parapet height HP = 3 ft
Building length L = 33.25 ft
Building width B = 24 ft
Natural frequency (Sec.6.2 & 6.5.8.2) n1 = 16.66667 Hz, (1 / T)
Effective area of mullion AM = 55 ft2
Effective area of panel AP = 27 ft2

DESIGN SUMMARY
Max building horizontal force normal to building length, L, face = 6.2 kips
Max overturning moment at wind normal to building length, L, face = 105.8 ft - kips
Max building horizontal force normal to building length, B, face = 4.2 kips
Max overturning moment at wind normal to building length, B, face = 66.1 ft - kips
Max building upward force = 9.2 kips
Max building torsion force = 25.9 ft - kips

ANALYSIS
Velocity pressures
qz = 0.00256 Kz Kzt Kd V2 I
where: qz = velocity pressure at height, z. (Eq. 6-15, page 27)
Kz = velocity pressure exposure coefficient evaluated at height, z. (Tab. 6-3, Case 2, page 79)
Kd = wind directionality factor. (Tab. 6-4, for building, page 80) = 0.85
z = height above ground
z (ft) 12 12 12 12 12 12 12 12 12 12 12 12
Kz 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57
qz (psf) 15.01 15.01 15.01 15.01 15.01 15.01 15.01 15.01 15.01 15.01 15.01 15.01

z (ft) 12 12 12 12 12 12 12 12 12 12
Kz 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57
qz (psf) 15.01 15.01 15.01 15.01 15.01 15.01 15.01 15.01 15.01 15.01

Design pressures for MWFRS


p = q G Cp - qh (G Cpi)
where: p = pressure on surface for rigid building with all h. (Eq. 6-17, page 28).
q = qz for windward wall at height z above the ground, see table above.
G Cp i = internal pressure coefficient. (Fig. 6-5, Enclosed Building, page 47) = 0.18 or -0.18
qh = qz value at mean roof height, h, for leeward wall, side walls, and roof.
Cp = external pressure coefficient, see right down tables.
G = gust effect factor (Sec. 6.5.8.1 & 6.5.8.2, Page 26)
  1  1.7 I g 2 Q 2  g 2 R 2  Iz = 0.30 z= 30 Q= 0.78
0.925  z Q R
 , for n1  1.0
  1  1.7 g v I z  zmin = 30 gQ = 3.4 Lz = 32
G  

= 0.796 c= 0.3 gR = 4.81 b= 0.05
 1  1.7 g Q I zQ 
0.925   , for n1  1.0
  1  1.7 g v I z  Rh = 0.097 RB = 0.038 RL = 0.008
N1 = 7.57 Rn = 0.039 R= 0.039

h= 9 gv = 3.4 Vz = 70.9

Fig. 6-6 fo q < 10o, page 48


Roof h/B Distance Cp
To L Face 0.50 6 -0.90
To L Face 0.50 12 -0.90
To L Face 0.50 24 -0.50
To L Face 0.50 24
Roof h/L Distance Cp
q G Cp Figure for Gable, Hip Roof, page 48 To B Face 0.36 6 -0.90
Fig. 6-6, page 48 To B Face 0.36 12 -0.90
Wall Direction L/B Cp To B Face 0.36 24 -0.50
Windward Wall All All 0.80 To B Face 0.36 33.25 -0.30
Leeward Wall To L Dir 0.72 -0.50
Leeward Wall To B Dir 1.39 -0.42
Side Wall All All -0.70
(cont'd)
Hence, MWFRS Net Pressures are given by following tables (Sec. 6.5.12.2.1, Page 28)

P (psf) with P (psf) with


Surface z (ft) GCPi - GCPi Surface z (ft) GCPi - GCPi
12 6.85 12.26 Side Wall All -11.06 -5.66
12 6.85 12.26

Normal to L Face P (psf) with Normal to B Face P (psf) with


Surface z (ft) GCPi - GCPi Surface z (ft) GCPi - GCPi
Leeward All -8.67 -3.27 Leeward All -7.75 -2.35

Normal to L Face P (psf) with Normal to B Face P (psf) with


Windward Wall

Surface Dist. (ft) GCPi - GCPi Surface Dist. (ft) GCPi - GCPi
0-6 -13.45 -8.05 0-6 -13.45 -8.05
12 -13.45 -8.05 12 -13.45 -8.05
Roof Roof
24 -8.67 -3.27 24 -8.67 -3.27
33.25 -6.28 -0.88

Figure 6-9, page 54


Normal to L Face Normal to B Face Wind with Angle
Base Forces ASCE-7
Case 1 Case 2 Case 1 Case 2 Case 3 Case 4
VBase (kips) 6 5 4 3 8 4
MBase (ft - kips) 106 79 66 50 129 70 Fig. 6-9
MT (ft - kips) 0 23 0 11 0 26 Page 52
FUpward (kips) 7 5 6 4 9 5
Vmin (kips) 4 4 3 3 5 5 Sec. 6.1.4.1

FUp,min (kips) 8 8 8 8 8 8 ( 10 psf )

Design pressures for components and cladding


p = q (G Cp) - qi (G Cpi)
where: p = pressure on component for building with h > 60 ft. (Eq. 6-23, page 29).
pmin = 10 psf (Sec. 6.1.4.2, page 21).
q = qz for windward wall at height z above the ground, see table above.
qh = qz value at mean roof height, h, for leeward wall, side walls, and roof.
G Cp i = internal pressure coefficient. (Fig. 6-5) = 0.18 or -0.18
a = Zone width = MAX[ MIN(0.1B, 0.1L), 3] = 3.0 ft, (Fig 6-17 note 8, pg 65)
G Cp = external pressure coefficient. (Fig. 6-17, page 65)
Wall Actual Effective Zone 4 Zone 5
Comp. Area ( ft2 ) GCP - GCP GCP - GCP
Mullion 55 0.81 -0.84 0.81 -1.55
Panel 27 0.87 -0.88 0.87 -1.73

Mullion Pressure (psf) Panel Pressure (psf)


z (ft) Zone 4 Zone 5 Zone 4 Zone 5
Positive Negative Positive Negative Positive Negative Positive Negative
12 14.79 -15.27 14.79 -25.94 15.79 -15.93 15.79 -28.60
12 14.79 -15.27 15.79 -25.94 15.79 -15.93 15.79 -28.60
cont'd
Effective Zone 1 Zone 2 Zone 3
Roof
Area ( ft2 ) - GCP - GCP - GCP
0 -1.40 -2.30 -3.20
10 -1.40 -2.30 -3.20
15.375 -1.35 -2.22 -3.10

Components and Cladding


20.75 -1.31 -2.17 -3.03
26.125 -1.28 -2.13 -2.98
31.5 -1.25 -2.09 -2.94
36.875 -1.23 -2.07
42.25 -1.22 -2.04
47.625 -1.20 -2.02
53 -1.19 -2.00
58.375 -1.17 -1.98
63.75 -1.16 -1.97
-1.16 -1.97
63.75 27
Effective Net Pressure (psf)
Roof
Area ( ft2 ) Zone 1 Zone 2 Zone 3
0 -23.71 -37.22 -50.73
10 -23.71 -37.22 -50.73
15.375 -22.89 -36.06 -49.24
Components and Cladding

20.75 -22.31 -35.26 -48.21


26.125 -21.87 -34.64 -47.41
31.5 -21.51 -34.14 -46.76
36.875 -21.21 -33.72
42.25 -20.95 -33.35
47.625 -20.72 -33.03
53 -20.51 -32.74
58.375 -20.33 -32.48
63.75 -20.16 -32.24
-20.16 -32.24