Magnetic Flowmeter Technical Datasheet

Magnetic Flow Sensor

Engineered and manufactured for the water and waste water industry
NSF Approved for potable water
Proven and unsurpassed lifetime performance
Long-term reliability and durability
Available IP68 rating
Available for direct burial installation
Magnetic flowmeters Product Charactors

Solution for the water & wastewater Industry

Magnetic flow meter principle

Electromagnetic flow meters, or magmeters, are comprised of a transmitter and sensor that together
measure flow. The magnetic flow meter’s sensor is placed inline and measures an induced voltage
generated by the fluid as it flows through a pipe. The transmitter takes the voltage generated by the sensor,
converts the voltage into a flow measurement and transmits that flow measurement to a control system.

E  K  B  D V
E : electromotive
K : k factor
B : magnetic strength
D : Diameter
V : Velocity

Under Faraday's law of induction, moving conductive liquids inside of a magnetic field
generates an electromotive force (voltage) in which the pipe inner diameter, magnetic field
strength, and average flow velocity are all proportional. In other words, the flow velocity of
liquid moving in a magnetic field is converted into electricity. (E is proportional to V × B × D)
Magnetic flowmeters Product Charactors

Basic parameters

■ Working temperature: -20 ℃ ~ +50 ℃

■ Operating humidity: ≦ 95%

■ Protection class: IP65 IP68

■ Flow rate measuring range: 0.2m/s --- 15 m / s

■ Medium conductivity: > 5μs / cm

■ For measuring diameter: DN3 --- DN3000

■ Supporting Accuracy class: 0.2% 0.5%

■ Measurementparameters: instantaneousflow, instantaneous flow rate

■ Record parameters: Flow cumulative total

■ Detection and alarm parameters: Fluid empty pipe detection alarm, the excitation

current detectionalarm

■ Scaled output signal: Unit volume flowpulse

■ Communication: RS485 (modbus protocol), GPRS

■ Power supply:AC 85-265 V50-60Hz

■ DC24V

■ 3.6V battery powered (output RS485+ pulse)


Magnetic flowmeters Electrode

Electrode material Applications

Applicable in water,sewage and corrosive mediums.


sainless steel SUS316
Widely used in industries of ,chemistry,fertilizer plant, power plant ,etc

Stainless steel covered


Applicable in mediums of non corrosive and low abrasion.
with tungsten carbide

Having strong resistance to hydrochloric acid of any consistance which

is below boiling point.

Hastelloy B(HB) Also resistable against vitriol,phosphate,

Hydrofluoric acid,organic acid etc which are oxidable acid,alkali and

non-oxidable salt.

Be resistant to oxidable acid such as nitric acid,mixed acid


Hastelloy C(HC)
as well as oxidative salt such as Fe+++,Cu++ and sea water

Applicable in seawater,and kinds of chloride,hypochlorite salt,oxidable

acid (including fuming nitric acid),organic acid,alkali etc.

Titanium Not resistant to a pure reducing acid(such as sulphuric acid,hydrochloric

acid corrosion.

But if acid contains antioxidant is greatly reduce corrosion.

Having strong resistance to corrosive mediums that is similar with glass

Tantalum Almost is applicable to all chemical mediums.

Except for hydrofluoric acid,oleum and alkali.

Platinum-iridium Almost be applicable in all chemical mediums except for ammonium salt.
Magnetic flowmeters Product liner

Material function Application

1.resistant to oil, solvent, oxidation, general acid and alkali corrosion. Can measure Waste water ,slurry
Neoprene 2. Excellent elasticity and wear resistance, but poor cold resistance.

1.It can work normally at -55℃ Can measure High temperature


Silicone rubber 2 outstanding heat resistance, long-term work at 180 ℃ fluid with not abrasive,no
corrosion content

1. good wear resistance and elasticity Can measure Healthy fluid


PU 2.Poor acid and alkali resistance

1.Hydrophobic and non-tacky, Can measure Waste


2.Strong high temperature resistance water ,slurry,coal slurry ,mud
3.Excellent corrosion resistance, (such as strong acid and alkali, organic slurry
PFA solvent and various salt solutions)
4.Good resistance to negative pressure, (metal mesh added can improved
negative pressure resistance
5., Poor wear resistance

1.Hydrophobic and non-sticky Can measure the slight abrasive


2.Corrosion resistance is second only to PFA 3.Metal mesh can be added to liquid between -25℃ and 100℃
F46 improve negative pressure resistance
4.Poor wear resistance

1.The most stable chemical material in plastics. (It can resistant to boiling Can measure Strong acid ,strong
hydrochloric acid/HCL, sulfuric acid/H₂SO₄ , nitric acid/HNO3 and aqua regia. ) alkali
2.Resistant to concentrated alkali and various organic solvents. ( not resistant
to chlorine trifluoride./CLF3 High temperature trifluorooxidation / OF3, high flow
rate liquid oxygen, liquid oxygen, ozone corrosion),
PTFE 3.Poor wear resistance,
4.Poor resistance to negative pressure, Easy to deform and crack

1.High wear resistance,


2.high negative pressure resistance,
3.Long-term stability and high accuracy
4.Excellent corrosion resistance, can measure mixed acid, aqua regia
Ceramic 5.Excellent heat resistance and cold and thermal shock resistance
FT3600 series

Advanced magnetic flow meter


High accuracy up to 0.2%
Suitable for many kinds of liner and electrode
US Gallon Unit are standard
The common type(not high frequency model) can be used to measure the paper
pulp.
Integral type

Remote type
Basic parameters

Measuring diameter DN3 ---DN3000

Flow rate measuring range 0.2m/s --- 15 m / s

Working temperature
-20 ℃ ~ +50 ℃

Medium conductivity
> 5μs / cm

Supporting Accuracy class


0.2% 0.5%

Instantaneous flow, instantaneous flow rate


Measurement parameters

Operating humidity: ≦ 95%

Protection class IP65 IP68

Detection and alarm parameters


Fluid empty pipe detection alarm, the excitation current detection alarm

Communication RS485 (modbus protocol),GPRS,

Flow Unit m³/h m³/m m³/s L/m L/h L/s UKG/h USG/h (standard)

Power supply DC 20-36V AC 85-250V 3.6V battery (Rs485+pulse)

Language ENGLISH display (other language can be customized)


Magnetic flowmeters magnetic flowmeter details

Gravimetric method calibration

with Sartorius scale which can reach to 0.016%


Calibrate size:DN10-600
Magnetic flowmeters magnetic flowmeter advantage
Magnetic flowmeters Flange magnetic flowmeter Dimension

External dimension reference


Nominal diameter Nominal
D H weight
pressure(Mpa) L of PTFE liner L of Neoprene liner

3 200(PFA) 90 220 4
6 200(PFA) 90 220 5
10 200 / 90 220 6
15 200 / 95 220 8
20 200 / 105 220 10
25 200 / 115 223 12
1.6-4
32 200 / 140 240 13
40 200 200 150 250 14
50 200 200 165 263 15
65 250 250 185 283 18
80 250 250 200 290 20
100 250 250 235 318 25
125 250 250 270 350 28
150 300 300 300 380 30
200 350 350 340 430 50
250 450 450 405 495 70
300 500 500 460 547 95
350 1.0-1.6 550 550 520 602 120
400 600 600 580 665 140
450 600 600 640 720 160
500 600 600 715 783 200
600 600 600 840 897 280
700 700 700 895 982 350
800 1.0 800 800 1015 1092 400
900 900 900 1115 1192 480
1000 1000 1000 1230 1299 550
1200 1200 1200 1405 1488 660
1400 1400 1400 1630 1700 750
1600 1600 1600 1830 1924 850
1800 1800 1800 2045 2134 980
0.6
2000 2000 2000 2265 2344 1200
2200 2200 2200 2475 2549 1600
2400 2400 2400 2685 2754 2000
2600 2600 2600 2905 3169 2400
2800 2800 2800 2905 3169 2700
3000 3000 3000 3315 3369 2900
Magnetic Flowmeters Flowmeter Selection Sheet

Magnetic Flowmeter Selection Questionaire

Item Remark

Fluid name

1 non metal tube


Pipe
2 metal tube without liner
material
3 metal tube with liner

Fluid temperature 1

DN DN3-DN2000

1 0.6 Mpa

2 1.0 Mpa

3 1.6 Mpa
Pressure
4 2.5 Mpa

5 4.0 Mpa

6 above 4.0 Mpa

carbon steel
Flange
a stainless steel

b clamp-on
Connection type
c thread

d Sanitary

e insertion

1 polychloroprene

2 PTFE

3 F46

4 PFA
Lining/liners
5 polyurethane

6 fluosilicic

7 ceramic

8 Hard Rubber

1 316L

2 HB

3 HC

4 Ti
Electrodes
5 Ta

6 platinoiridium

7 Tungsten carbide

8 TiB2
M Magnetic Flowmeters Flowmeter Selection Sheet

1 compact/integrated
2 separated/remote
Model
3 compact with anti-explosion
4 separate with anti-explosion
1 AC 220V
Power supply 2 DC24-36V
3 3.6V battary power
1 4-20mA pulse
2 4-20mA /RS232C
Output 3 4-20mA /RS485
4 HART
5 no output(battary power)
1 0.2% R
Accuracy degree 2 0.5% R
3 1.0% R
1 IP 65
2 sensor IP68.transmitter IP65
Ingress protection
3 sensor IP67.transmitter IP65
4 IP68
1 none
2 grouding ring
3 matched flanges

Accessories

4 others

Kaifeng Fantai Measurement and Control Technology Co.,Ltd


Tel:0086-371-23217168
Whatsapp:008615188350209