NUFLO™
MC-III™ WP
Flow Analyzer
The NuFlo MC-III WP Flow Analyzer offers state-of-the art liquid and gas
measurement with data logging and Modbus communications in an easy-to-use
weatherproof totalizer. With the capacity to record up to 384 daily flow logs,
768 hourly logs, and 345 event logs, the MC-III WP is a powerful addition to
any flow measurement operation.
Features
The MC-III WP offers:
• RS-485 Modbus communications • Simultaneous indication of
• Extensive log archival capacity rate and total
• High-speed downloads (less than • Loop-powered analog output
a minute, based on 115K baud) • Nonvolatile memory
Modbus communication,
• Easy-to-read LCD displays • Password-protected logging and accurate
security options flow measurement – all
• 12-point linearization
in one compact weather-
proof device
ENTER
The MC-III WP Flow Analyzer connects to a turbine meter or a pre-amplifier. Users The wide variety of unit options for total and
can select a 4-20 mA output, a pulse output, or an amplified flowmeter frequency rate gives users the freedom to customize the
output that allows remote equipment to calculate flow rates and volume. display, inputs, and outputs for specific needs.
MEASUREMENT SYSTEMS
Display Outputs
• 8-digit display of Total Analog Output
• 6-digit display of Rate (11-segment • 4-20 mA, loop-
characters for easy-to-read prompts) powered (two-wire)
• Character height - 0.300 in. • 16-bit resolution
• Adjustable contrast and update • Accuracy: 0.1% of
period FS @ 25°C,
• User-selectable units of measurement: 50 PPM/°C
• Total: bbl, gal, liters, cubic meters, temperature drift
cubic feet, standard cubic feet, • Loop power:
user-defined units (and all units 8.0 to 30 VDC
x 1000)
• Zero and full-scale
• Rate: Any of the above Total
engineering values
engineering units per day, hour,
minute, or second configurable from
front panel
Power Supply Options RS-485 Communications Flow Archive
• 3.6 VDC lithium battery pack • Baud rates: 300, 600, 1200, 2400, • 384 daily logs
– 2-year typical life (main or backup 4800, 9600, 19200, 38400, 57600 • 768 hourly logs
power supply) and up to 115.2K • 345 event logs
• Alkaline battery pack option Volumetric Pulse Output • K-factor changes
(main or backup power supply) • Solid-state relay • Input setting changes
• External power supply (6 to 30 VDC) • Output rating: 60 mA max @ 50 VDC
with internal battery backup Communications/
• Configurable pulse duration and Archive Retrieval
• Loop-powered (4-20 mA output)
scale factor • RTU mode Modbus
with internal battery backup
Amp and Square Output • Enron Modbus
Temperature Range • Open-drain transistor output of • 16-bit slave address supported
• Lithium battery: -40°F to +158°F turbine meter input signal • Data printouts in tabular or
(-40°C to +70°C) • Output rating: 50 mA @ 30 VDC chart formats
• Alkaline battery pack: 20°F to 140°F (Analog output and amp and • Data export to spreadsheet
(-7°C to 60°C) square outputs cannot be used (.xls and .csv formats)
simultaneously)
• LCD contrast is reduced below -20°C MC-III Interface Software
Certification • Provided at no additional charge
Inputs The MC-III WP is available with either of • Complete configuration to include
Turbine Meter Input two certification levels. Please specify at multi-point and gas calibration
• Configurable sensitivity adjustment the time of order. • Real-time data
• Frequency range: 0 to 3500 Hz • Hazardous area certification • Downloads
Remote Reset Input • CSA approved for US and Canada • Reports
• Optically isolated • Class I, Div. 2, Groups A,B,C,D • Charts
• Type 4 enclosure • Exports to .xls and .csv formats
• Supply range: 3.0 to 30 VDC
• Type 5 temperature class • “Wizard” offers step-by-step
Pulse Input
• Ordinary locations calibration procedure
• Optically isolated (nonhazardous area) certification • Windows® 2000 or XP required
• Supply range: 3.0 to 30 VDC • CSA approved for US and Canada
• Type 4 enclosure