3400 / 4400

CONFIGURABLE CONTROLLERS

Main features
• Cascade control
• Ratio control
• Square root extraction on input signal
• Programmer with 4 setpoints and
4 ramps
• Thermocouple or resistance
thermometer inputs and linear inputs
Main applications with configurable scale and
• Climatic chambers and test linearisation
benches • Isolated inputs for remote setpoint,
• Furnaces and ovens that require valve position feedback signal or load
a setpoint that varies with time break detection
• Steriliser, autoclaves, • Two control outputs with
dryers, plant for transformation independent PID parameters
• Chemical and pharmaceutical (Heat/Cool)
industries • AUTO/MAN station with bumpless
• Food processing plants transfer incorporated
• Water treatment • Configurable output for a
• Siderurgy industry retransmission signal
• Furnaces for ceramics and • Serial line: optoisolated 4-wires
bricks configurable.
• Heat exchange control Protocol: GEFRAN CENCAL

GENERAL TECHNICAL DATA


Microprocessor controller in 48x96 / The instrument has up to four outputs,
each one factory configured, according to INPUTS
96x96mm format (1/8 DIN -1/4 DIN).
the order code, as relay, isolated logic, Accuracy 0,1% f.s. ± 1 digit
Manufactured using SMT, the 3400 provi-
isolated analogue or interface for MD81 Sampling time 120msec
des a complete operator interface with
IP54 level of protection (IP65 with face- expansion unit output. TC- Thermocouple
plate cover). The output functions are configurable J (Fe-CuNi) 0...1000°C / 32...1832°F
The faceplate has a membrane keypad from the faceplate. K (NiCr-Ni) 0...1300°C / 32...2372°F
with 6 keys, a backlit LCD display that is Apart from the control outputs, that can R (Pt13Rh-Pt) 0...1750°C / 32...3182°F
available also with large dimensions be heat-cool with independent PID, and S (Pt10Rh-Pt) 0...1750°C / 32...3182°F
(model 4400) that displays the process the alarm outputs, outputs can be dedica- T (Cu-CuNi) -100...400°C / -148...752°F
variable, setpoint, bargraphs of the per- ted to the open/close control of a motori- B (Pt30Rh-Pt6Rh) (*) 50...1800°C / 122...3272°F
centage output power and the deviation sed valve (with or without position feed- E (NiCr-CuNi) -100...750°C / -148...1382°F
and indication of the alarm and controller back potentiometer), retransmission
N (NiCr-Si-NiSi) 0...1300°C / 32...2372°F
states. signal of the measured variable, the set-
Ni-Ni18Mo (Ni-Ni18Mo)
The main input for the control variable is point, the deviation or the control of the
0...1100°C/ 32...2012°F
universal and gives the possibility to con- MD8 expansion unit for an extra 8
(*) for type B thermocouples, the class of
nect a wide range of sensors such as alarms.
accuracy is valid for temperatures above
thermocouples, resistance thermometers The 3400/4400 series controllers can be
used as setpoint programmers with up to 500°C.
or mV signals even with custom linearisa-
tion. 8 segments (4 ramps and 4 holds). RTD 2/3-wires
A second auxiliary analogue input is avai- Other control functions are also available Pt100 -200...600°C / -328...1112°F
lable for remote setpoint linear signal, such as ratio control between two varia-
DC - Linear
potentiometer valve position feedback or bles and cascade control with specific
0...50mV, 10...50mV
input from a current transformer. and configurable parameters.
The serial communication option can be External shunts are used for voltage ran-
With a digital input it is possible to select ges 0...10V and current ranges of
between two preset setpoints or switch for Current Loop, RS232 or RS485 and it
is possible to read and write any of the 0...20mA and 4...20mA.
between local and remote setpoint.
instrument’s parameters. Custom 32 segment characterisation.
With three isolated digital inputs, it is pos-
The programming procedure is simplified Ri > 1MΩ.
sible to select one of four setpoint pro-
grammes or supply a start, stop and reset by the menu guide structure with different
signal, or select local/remote, configuration levels for a rapid and easy
auto/manual or hold. access to the data.
Auxiliary input Logic • Offset of the secondary input ±999 scale
Isolated 1500V 23Vdc, Rout = 470Ω (20mA, max.12V). digits
For remote setpoint: Voltage output for SSRs. • Digital filter on the input variable:
0...10V - Ri > 100KΩ 0,1...20,0 sec
MD81
0...20mA - Ri = 50Ω Mathematical operations on input signal:
MD81 expansion unit of the alarms
4...20mA - Ri = 50Ω square root extraction:
(alarms 3...10)
For potentiometer: (A x Input ^D + B)/C
0...1V - Ri > 10MΩ (potentiometer with Scale configurable in the range:
SERIAL LINE
value from 100Ω to 20KΩ) -1999...9999.
The instrument is equipped with Passive
For current transformer: • Reset power for direct / inverse action
Current Loop (1200 baud) interface or
0...5Aac, 50/60Hz - Ri = 20mΩ (0...100% / 0...-100%)
RS422/485, RS232 (1200 / 2400 / 4800 /
• Antireset (limitation band for the integral
Digital 9600 baud).
action) 0...9999 scale digits
Isolated 1500V Protocol: GEFRAN CENCAL
• Feed Forward 500...-199%
3 isolated command inputs for
• Integral time for direct / inverse action
Start/Stop/Reset functions, Set POWER SUPPLY 0,00...99,99 min
Locale/Remoto, Auto/Man, Hold, direct 100...240Vac/dc ± 10%, 50/60Hz • Derivative time for direct / inverse action
selection of one of the four program set- 12VA max (3400), 15VA max. (4400) 0,00...9,99 min
points: Protection by internal fuse not serviceable • Maximum/minimum limit of the
- NPN 12V/3,5mA by the user. direct/inverse action output 0...100%
- PNP 24V/6mA (12V/2mA)
The main control and support functions
OUTPUTS AMBIENT CONDITIONS are:
Working temperature: 0...50°C • Soft-start: gradual increase of the main
Isolated 1500V Storage temperature: -20...70°C output after power-up of the instrument
Maximum and minimum adjustment from Humidity: 20...85%Ur non condensing over a time 0,0...100,0 min
the faceplate keys: • Self-Tuning: automatic research for the
• Direct control (Heat) CONTROLLER optimal control parameters during the
• Inverse control (Cool) On/Off, P, PD, PI, PID control with inde- start-up phase.
• Retransmission of local or remote set- pendent and adjustable parameters for • Auto-Tuning: automatic update of the
point both the direct and the inverse actions. tuning parameters following a variation of
• Retransmission of the input signal By selecting a configuration parameter, the controlled system and/or of the set-
• Retransmission of the deviation signal the controller may be configured as: point.
between the values of the setpoint and single loop, ratio and cascade controller. • AUTO/MAN station with bumpless tran-
the input. • Cool setpoint relative to the heat setpoint sfer incorporated
• Alarm 1 or 2 ±25,0% f.s. • LBA: Loop Break Alarm with adjustable
• Open/Close for valve positioner motor • Two control outputs (Heat/Cool) with the delay (0,0...20,0 min) and power
Continuous Cool setpoint entered in the range: (0,0...100,0%) of intervention
0...10V max 20mA ±25,0% f.s. with respect to the Heat set- • HB: Heater Break or alarm for interrup-
0...20, 4...20mA Rmax = 500Ω point ted load with reference to the current
Resolution 4000 steps, max. update time • Proportional band for direct action (Heat) transformer input.
80msec. 0,0...999,9% f.s.
• Proportional band for direct action (Cool) PROGRAMMER
Relay 0,0...999,9% f.s. The programmer function enables the
Contact, which can be selected as • Manual reset (deviation correction factor) controlled variable to follow a profile of 8
NO/NC rated at 5A/250Vac at cosϕ = 1 ±999 scale digits segments (4 setpoints and 4 ramps).
(with resistive load) with spark suppres- • Offset of the primary input ±999 scale Each step is defined by the following
sion on the NO contact. digits data:

FACEPLATE DESCRIPTION

A - Indication of process variable,


digits h. 10mm (3400) and 20mm (4400)
B - Indication of setpoint,
digits h. 7mm (3400) and 14mm (4400)
C - Deviation display A
A
D - Main output display B
E - Function key C
M B
F - G - Lower/Raise keys
D C
H - Data key
I - Man/Auto key F M
L - Local/Remote key G E D
M - Status indicator L H

LCD backlit display I L I H G F E


IP54 faceplate protection (IP65 available)
• Setpoint - display and modify the set of the pro- selected scale.
• Time of setpoint and of programmable gram being run. - Programmable hysteresis for each
ramp up to 99days 23hrs 59min. 59sec. alarm ±999 scale digits.
ALARMS
• Accuracy of the time base: better than - Non-repetitive response time:
• 2 + 8 (with the MD81 expansion unit)
±4 sec every 10 hours. max. 80msec.
alarm levels that may be set as an abso-
• H: Holdback band or maximum allowed - Indication: the messages AL1 and AL2
lute, relative or symmetrically relative
deviation for the running of the program: appear or the LEDs of the MD81 alarm
value with respect to the setpoint or auxi-
1...1000 scale digits. unit light up in phase of entering the rela-
liary input; with direct or inverse action
Program START/STOP/RESET com- tive setpoints, and flash when the output
and possibility to inhibit the alarm during
mands: relay is energised or the output is active.
power-up.
- from the faceplate keys,
- The faceplate keys are used to configu-
- from the logic inputs, WEIGHT
re the alarms in condition of LBA, HB, H
- from serial line 600g (3400)
and end-of program alarms.
In the STOP condition, it is possible to: 850g (4400)
- Programmable limits for the entered
- vary the value of the current setpoint
parameters may be configured within the
using the Raise and Lower keys.

DIMENSIONS AND CUT-OUT

96 115
48 70

108 96
108 96

115
115

92
92

157 157

44,5 92

10
10

Dimensions: 48x96mm - 96x96mm (1/8 DIN - 1/4 DIN), depth 157mm

CONNECTION DIAGRAM

PWR
SUPPLY SERIAL
COM LINE
OPEN NO / NC

COM
HEAT C COM
VALVE
OUTPUT CLOSE NO / NC IN1 EN
AUXILIARY
COOL IN2
COM C C INPUT
CLOCK NO / NC IN3
OUT1
MD8 DATA (AL1) C

NO / NC
OUT2
OUT W (AL2) C

TC Pt100 PTC Pt100 mAdc


3-wires Pt100 4-wires Vdc
2-wires

Only for 4400 mod.


! Apply users’ manual warnings for a correct installation
ORDER CODE

MODEL DIGITAL COMMUNICATION


3400 3400 0 None
4400 4400 1 Current Loop
2 RS422/485
INPUTS 3 RS232C
TC/RTD 2/3-wires 0...50mV A
RTD 4-wires B OUTPUT 4
0...10V C 0 None
0/4...20mA D R Relay
D Logic
AUXILIARY INPUTS V Continuous 0...10V
None 0 I Continuous 0/4...20mA
0...1V 1 M MD81 expansion
0...10V 2 T Transmitter supply
0/4...20mA 3
Potentiometer 4 OUTPUT 3
Current Transformer 0 None
5
(4400 only) R Relay
D Logic
IN2, IN3 DIGITAL INPUTS V Continuous 0...10V
None 0 I Continuous 0/4...20mA
NPN 1 M MD81 expansion
PNP 2 T Transmitter supply
For 3400 these are available only with:
auxiliary input = 0
OUTPUT 2
0 None
R Relay
D Logic
V Continuous 0...10V
I Continuous 0/4...20mA
M MD81 expansion
T Transmitter supply

OUTPUT 1
0 None
R Relay
D Logic
V Continuous 0...10V
I Continuous 0/4...20mA
T Transmitter supply

Please, contact GEFRAN sales people for the codes availability.

GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice

The instrument conforms to the European Directives 2004/108/CE and 2006/95/CE with reference to the generic standards:
EN 61000-6-2 (immunity in industrial environment) EN 61000-6-3 (emission in residential environment) - EN 61010-1 (safety)

GEFRAN spa via Sebina, 74 - 25050 Provaglio d’Iseo (BS)


Tel. 03098881 - fax 0309839063 - Internet: http://www.gefran.com DTS_3400-4400_0409_ENG