You are on page 1of 1

TABLE 4.

5
Summary Sheet for Continuing Example Scenario 2a—Fatality Frequency Criteria Method
(Method 3 of Chapter 3)
Scenario Number: 2a Equipment Number: Scenario Title: Hexane Storage Tank Overflow Spill
not contained by the dike

Frequency (per
Date: Description Probability year)

Consequence Descrip- Tank overflow and spill of hexane outside dike.


tiop/Category Potential for flash fire and pool fire with
probable ignition, injury, and fatality

Risk Tolerance Criteria


(Category or Frequency)
Initiating Event (typically a Arrival of tank truck with insufficient room in
frequency) the tank due to failure of the inventory control
system. Frequency based upon plant data.

Enabling Event or Con- dition

Conditional Modifiers (if applicable)


Probability of ignition
Probability of personnel in affected area
Probability of fatal injury
Others
Frequency of Unmitigated Consequence
Independent Protection Layers
None identified at this stage of the analysis.
See Notes (below)

Safeguards(non-IPLs) See Notes (below)

Total PFD for all IPLs


Frequency of Mitigated Consequence
Risk Tolerance Criteria Met? (Yes/No):
Actions Required to Meet Risk Tolerance Criteria:
Notes: Consider if the following devices, systems or actions are IPLs: human intervention, other BPCS control
loops, dike
References (links to originating hazard review, PFD, P&ID, etc.):
LOPA analyst (and team members, if applicable):