Professional Documents
Culture Documents
SN75115
SN75115
VCC
Designed to Be Interchangeable With
1YP
1YS
2YS
NC
National DS9615 Line Receivers
3 2 1 20 19
description 1STRB 4 18 2YP
1RTC 5 17 2STRB
The SN55115 and SN75115 dual differential line
NC 6 16 NC
receivers are designed to sense small differential
1B 7 15 2RTC
signals in the presence of large common-mode
1RT 8 14 2B
noise. These devices give TTL-compatible output 9 10 11 12 13
signals as a function of the differential input
2RT
1A
2A
NC
GND
voltage. The open-collector output configuration
permits the wire-ANDing of similar TTL outputs
(such as SN5401/SN7401) or other NC – No internal connection
SN55115/SN75115 line receivers. This permits a
level of logic to be implemented without extra
delay.
The output stages are similar to TTL totem-pole outputs, but with sink outputs, 1YS and 2YS, and the
corresponding active pullup terminals, 1YP and 2YP, available on adjacent package pins. The frequency
response and noise immunity may be provided by a single external capacitor. A strobe input is provided for each
channel. With the strobe in the low level, the receiver is disabled and the outputs are forced to a high level.
The SN55115 is characterized for operation over the full military temperature range of – 55°C to 125°C. The
SN75115 is characterized for operation from 0°C to 70°C.
FUNCTION TABLE
OUTPUT
DIFF INPUT (YP AND YS
STRB
(A AND B) TIED
TOGETHER)
L X H
H L H
H H L
H = VI ≥ VIH min or VID more positive than VT + max
L = VI ≤ VIL max or VID more negative thanVT – max
X = irrelevant
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date. Copyright 1998, Texas Instruments Incorporated
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
logic symbol†
5 &
1B
7 2
1A 1YP
6
1RT RT
3 1
1STRB 1YS
4
1RTC RSP
11
2B
9 14
2A 2YP
10
2RT
13 15
2STRB 2YS
12
2RTC
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
11
2B 14 2YP (Pullup)
9
2A 15 2YS (Sink)
10
2RT
12
2RTC
13
2STRB
3k
Input 5.11
B 1,15 Sink
Output
130 150 YS
150 1.5 k
150 8
GND
Common to
Both Receivers
2.5 k
V
150
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage VI (A, B, and RT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±25 V
Input voltage VI (STRB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Off-state voltage applied to open-collector outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 V
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
Case temperature for 60 seconds: FK package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: J or W package . . . . . . . . . . . . . . . . 300°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: N package . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values, except differential input voltage, are with respect to network ground terminal.
Common-mode + 15 + 24 + 15 + 24
VICR VID = ± 1 V to to to to V
input voltage range – 15 – 19 – 15 – 19
TA = MIN 2.2 2.4
High-level
Hi hl l ouputt VCC = MIN
MIN, VID = – 0.5
0 5 V,
V
VOH TA = 25°C 2.4 3.4 2.4 3.4 V
voltage IOH = – 5 mA
TA = MAX 2.4 2.4
Low-level output VCC = MIN, VID = – 0.5 V,
VOL 0.22 0.4 0.22 0.45 V
voltage IOL = 15 mA
TA = MIN – 0.9 – 0.9
L l l input
Low-level i t MAX
VCC = MAX, 0 4 V,
VI = 0.4 V
IIL TA = 25°C – 0.5 – 0.7 – 0.5 – 0.7 mA
current Other in ut at 5.5
input 55V
TA = MAX – 0.7 – 0.7
High-level
g strobe VCC = MIN,, VID = – 0.5 V,, TA = 25°C 2 5
ISH µA
current Vstrobe = 4.5 V TA = MAX 5 10
Low-level strobe VCC = MAX, VID = 0.5 V,
ISL TA = 25°C – 1.15 – 2.4 – 1.15 – 2.4 mA
current Vstrobe = 0.4 V
Response-time- VCC = MAX, VID = 0.5 V,
I(RTC) TA = 25°C – 1.2 – 3.4 – 1.2 – 3.4 mA
control current VRC = 0
VCC = MIN,, VOH = 12 V,, TA = 25°C 100
Off-state VID = – 4.5 V TA = MAX 200
IO(off) open-collector
open collector µA
output
out ut current VCC = MIN,, VOH = 5.25 V,, TA = 25°C 100
VID = – 4.75 V TA = MAX 200
Line-terminating
RT VCC = 5 V TA = 25°C 77 130 167 74 130 179 Ω
resistance
Supply-circuit output VCC = MAX, VID = – 0.5 V,
IOS TA = 25°C – 15 – 40 – 80 – 14 – 40 – 100 mA
current # VO = 0
Supply current VCC = MAX, VID = 0.5 V,
ICC TA = 25°C 32 50 32 50 mA
(both receivers) VIC = 0
† Unless otherwise noted, Vstrobe = 2.4 V. All parameters with the exception of off-state open-collector output current are measured with the active
pullup connected to the sink output.
‡ All typical values are at VCC = 5 V, TA = 25°C, and VIC = 0.
§ Differential voltages are at the B input terminal with respect to the A input terminal.
¶ The algebraic convention, in which the less positive (more negative) limit is designated as minimum, is used in this data sheet for threshold
voltages only.
# Only one output should be shorted to ground at a time, and duration of the short circuit should not exceed one second.
NOTES: A. The pulse generator has the following characteristics: ZO = 50 Ω, PRR ≤ 500 kHz, tw ≤ 100 ns, duty cycle = 50%.
B. CL includes probe and jig capacitance.
TYPICAL CHARACTERISTICS†
INPUT CURRENT
vs
INPUT VOLTAGE
6
VCC = 5 V
Input Not Under Test at 0 V
4 TA = 25°C
–2
–4
–6
– 25 – 20 – 15 – 10 – 5 0 5 10 15 20 25
VI – Input Voltage – V
Figure 2
ÎÎÎÎÎ
4
ÎÎÎÎ 6
ÎÎÎÎÎÎÎÎÎ
VCC = 4.5 V No Load
3.4 TA = 25°C
ÎÎÎÎÎÎÎÎÎ
3.2 VOH (VID = – 0.5 V, IOH = – 5 mA)
ÎÎÎÎ
5
VCC = 5.5 V
CC – Output Voltage – V
VO – Output Voltage – V
ÎÎÎÎÎ
ÎÎÎÎ
2.8 VCC = 5 V
4
ÎÎÎÎÎ
2.4 VCC = 4.5 V
ÁÁ
2
ÎÎÎÎ 3
ÁÁ
1.6
ÁÁ ÎÎÎÎ 2
VID = – 1 V
IICC
ÁÁ ÎÎÎÎÎÎÎÎÎ ÁÁ
VO
1.2
ÎÎÎÎ
0.8
1
ÎÎÎÎÎÎÎÎÎ ÎÎÎÎ
0.4 VOL (VID = 0.5 V, IOL = 15 mA) VID = 1 V
0 0
– 75 – 50 – 25 0 25 50 75 100 125 – 25 – 20 – 15 – 10 – 5 0 5 10 15 20 25
TA – Free-Air Temperature – °C VIC – Common-Mode Input Voltage – V
Figure 3 Figure 4
† Data for temperatures below 0°C and above 70°C and for supply voltages below 4.75 V and above 5.25 V are applicable to SN55115 circuits
only. These parameters were measured with the active pullup connected to the sink output.
TYPICAL CHARACTERISTICS
ÎÎÎÎÎ
HIGH-LEVEL OUTPUT CURRENT LOW-LEVEL OUTPUT CURRENT
0.4
ÎÎÎÎÎ ÎÎÎÎ
5
VID = – 0.5 V VID = 0.5 V
ÎÎÎÎÎ
ÎÎÎÎÎ ÎÎÎÎ
TA = 25°C TA = 25°C
VOH – High-Level Output Voltage – V
ÎÎÎÎ
0.3
ÎÎÎÎÎ
VCC = 5 V VCC = 4.5 V
3
ÎÎÎÎÎ
VCC = 5.5 V
ÎÎÎÎÎ
0.2
VCC = 4.5 V
2
ÁÁ ÁÁ
ÁÁ ÁÁ
0.1
VOL
VOH
0 0
0 –10 – 20 – 30 – 40 – 50 0 5 10 15 20 25 30
IOH – High-Level Output Current – mA IOL– Low-Level Output Current – mA
Figure 5 Figure 6
4 4
TA = 25°C
3 3
TA = – 55°C
ÁÁÁ 2
ÁÁ 2
ÁÁÁ ÁÁ ÁÁÁÁÁÁ
VO
VO
1 1
0
– 0.2 – 0.1 0 0.1 0.2
ÁÁÁÁÁÁ 0
Load = 2 kΩ to VCC
TA = 25°C
Figure 7 Figure 8
TYPICAL CHARACTERISTICS†
ÁÁÁÁÁ ÁÁÁÁ
STROBE INPUT VOLTAGE STROBE INPUT VOLTAGE
ÎÎÎÎÎ
ÁÁÁÁÁ ÁÁÁÁ
6 6
No Load
ÎÎÎÎÎ
ÁÁÁÁÁ ÁÁÁÁ
VCC = 5 V
VID = 0.5 V
No Load
ÁÁÁÁÁ ÁÁÁÁ
5 TA = 25°C 5 VID = 0.5 V
VCC = 5.5 V
VO – Output Voltage – V
VO – Output Voltage – V
4 4
TA = 125°C
3 3
ÁÁ ÎÎÎÎ ÁÁ
VCC = 5 V TA = – 55°C
ÁÁ ÁÁ
2 2
VO
VO
VCC = 4.5 V
TA = 25°C
1 1
0 0
0 0.5 1 1.5 2 2.5 3 3.5 4 0 0.5 1 1.5 2 2.5 3 3.5 4
Vstrobe – Strobe Input Voltage – V Vstrobe – Strobe Input Voltage – V
Figure 9 Figure 10
ÎÎÎÎ
60 40
ÎÎÎÎ
No Load
TA = 25°C 35
50
I CC – Supply Current – mA
30
CC – Supply Current – mA
40 B Input at VCC
A Input at 0 V 25
30 20
ÁÁ ÁÁ
ÁÁ
B Input at 0 V 15
20 A Input at VCC
ÁÁ ÁÁ ÎÎÎÎÎÎÎÎ
ICC
IICC
10
VCC = 5.5 V
10
ÎÎÎÎÎÎÎÎ
5 B Input at 5.5 V
A Input at 0 V
0 0
0 1 2 3 4 5 6 7 8 – 75 – 50 – 25 0 25 50 75 100 125
Figure 11 Figure 12
† Data for temperatures below 0°C and above 70°C and for supply voltages below 4.75 V and above 5.25 V are applicable to SN55115 circuits
only. These parameters were measured with the active pullup connected to the sink output.
TYPICAL CHARACTERISTICS†
15
tPLH (RL = 3.9 kΩ) 10k
10
5 fmax
1k
ÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎ
VCC = 5 V
ÎÎÎÎ
Input: – 0.5-V to 0.5-V Square Wave
TA = 25°C
0 100
– 75 – 50 – 25 0 25 50 75 100 125 0.001 0.01 0.1 1 10
TA – Free-Air Temperature – °C Response-Time-Control Capacitance – µF
Figure 13 Figure 14
† Data for temperatures below 0°C and above 70°C and for supply voltages below 4.75 V and above 5.25 V are applicable to SN55115 circuits
only. These parameters were measured with the active pullup connected to the sink output.
APPLICATION INFORMATION
Location 3 Location 5
ZO‡ ZO‡
Location 1 Location 6
SN75113 Driver
SN75115 Receiver
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.