You are on page 1of 2

P.T .

ZinkPower Austrindo - Tangerang 15345

Certificate
Hot Dip Galvanizing
No. 1911/ZPA/CERT/VII/2023 Page : 1 of 2

We confirm that PT. Zinkpower Austrindo has Hot Dip Galvanized in accordance with ASTM A 123 for the following
customer and we certify that :

CUSTOMER : PT. SPACE TECHNOLOGY


DATE OF CHECKING : July 20, 2023
PROJECT : CABLE TRAY THK. 2.6MM

PO NO :
DN NO : DO NC-E/23/07/024

The following materials with following results :


Average Coating
Type Size Quantity
Thickness (µm)
PERFORATE TYPE CABLE TRAY 100W X 3000 2.6 mm 199 pc s 80
PERFORATE TYPE CABLE TRAY 150W X 3000 2.6 mm 200 pc s 78
90 HORIZONTAL ELBOW 300W X 150H 2.6 mm 14 pc s 86
90 HORIZONTAL ELBOW 900W X 150H 2.6 mm 5 pc s 82
HORIZONTAL CROSS 900W X 150H 2.6 mm 1 pc s 78
STRAIGHT LADDER TYPE CABLE TRAY 600W X 150H X 3000L 2.6 mm 12 pc s 87

Minimum coating requirements under ASTM A 123 standard :


All Specimens Tested
Material Category Steel Thickness Range (Measured), in (mm)
< 1.6 >=1.6 to <3.2 >=3.2 to <4.8 >=4.8 to <6.4 >=6.4 to <16 >=16
Structural Shapes 45 65 75 75 100 100
Strip and Bar 45 65 75 75 75 100
Plate 45 65 75 75 75 100
Pipe and Tubing 45 45 75 75 75 75
Wire 35 50 60 65 80 80
Reinforcing Bar ... ... ... ... 100 100

The Galvanizer is not responsible for corrosion, discoloration or distortion affected by :


1. Defects in welding or base metal.
2. Inadequate cleaning of welding slag.
3. Unsuitable construction design for Hot Dip Galvanizing.
4. Storage or transportation under poorly ventilated conditions.
5. Modification made to the structure after galvanizing.

July 26, 2023


PT. Zinkpower Austrindo

Binsar Simanjuntak
Production Manager
QDS/0-84A
P.T . ZinkPower Austrindo - Tangerang 15345

Certificate
Hot Dip Galvanizing
No. 1911/ZPA/CERT/VII/2023 Page : 2 of 2

We confirm that PT. Zinkpower Austrindo has Hot Dip Galvanized in accordance with ASTM A 123 for the following
customer and we certify that :

CUSTOMER : PT. SPACE TECHNOLOGY


DATE OF CHECKING : July 20, 2023
PROJECT : CABLE TRAY THK. 2.6MM

PO NO :
DN NO : DO NC-E/23/07/024

The following materials with following results :


Average Coating
Type Size Quantity
Thickness (µm)
90 HORIZONTAL ELBOW 600W X 150H 2.6 mm 24 pc s 78
STRAIGHT LADDER TYPE CABLE TRAY 300W X 150H X 3000L 2.6 mm 8 pc s 86

Minimum coating requirements under ASTM A 123 standard :


All Specimens Tested
Material Category Steel Thickness Range (Measured), in (mm)
< 1.6 >=1.6 to <3.2 >=3.2 to <4.8 >=4.8 to <6.4 >=6.4 to <16 >=16
Structural Shapes 45 65 75 75 100 100
Strip and Bar 45 65 75 75 75 100
Plate 45 65 75 75 75 100
Pipe and Tubing 45 45 75 75 75 75
Wire 35 50 60 65 80 80
Reinforcing Bar ... ... ... ... 100 100

The Galvanizer is not responsible for corrosion, discoloration or distortion affected by :


1. Defects in welding or base metal.
2. Inadequate cleaning of welding slag.
3. Unsuitable construction design for Hot Dip Galvanizing.
4. Storage or transportation under poorly ventilated conditions.
5. Modification made to the structure after galvanizing.

July 26, 2023


PT. Zinkpower Austrindo

Binsar Simanjuntak
Production Manager
QDS/0-84A