You are on page 1of 7

 

Steel Porta Cabin 

NOTIFICATIONS

HomeLand and Buildings and Structures and ThoroughfaresPortable buildings and structuresPortable Commercial and industrial buildings and structuresSteel Porta Cabin (Q3 Category)

Tata Steel MobiNest Portable Cabin Steel Porta


Cabin consist of With one Room and Verandah.
Tata Steel MobiNest Portable CabinR
(ALUMINIUM CABIN SIZE 10'X12'X7' AS DIRECTED BY
USERS)

Rs. 12,450.00 85% OFF

Trends

Product Details

Price For : 1 pieces

MRP/Unit: Rs. 85,000.00


Offer Price/Unit: Rs. 12,450.00

Availability: 10 In Stock

Min. Qty. Per Consignee: 8

Product id: 5116877-48043757227

Country Of Origin: India

Local Content (MII): Not Declared

Seller Details

Sold by: Resellers

Reseller not verified by OEM

Catalogue not verified by OEM

Seller Excellence 4.5 - 5.0

Seller Details VIEW ALL SELLERS

REPORT THIS PRODUCT

Specifications

Configuration of Cabin With one Room and Verandah.

Approval of Advance sample After award of contract - Seller shall


have to get proto type Advance
Ask GeMmy sample approved from Buyer before
manufacturing / starting Bulk
supplies - Buyer shall approve /
provide list of modifications required
within 10 days of offer of advance
sample - If there is delay in approval
of advance sample from Buyer side -
the delivery period shall be
regularized for the period of delay in
sample approval.

Time period for completion of Within 20 days of the date of receipt


Erection work at site by seller of consignee's confirmation
regarding completion of ground and
foundation work

Suitability / structural stability / In wind condition of 55m/s - in


completness of structures, the Seismic zone V and ambient
structure is intended for use in temperature range (-) 40 degree C to
(+) 50 degree C - 1 M snow load
standing on the roof - Roof slope 1 : 2
Cabin should be structurally stable
and suitable to meet severity of these
climatic condition.

Type of slope(roof) One way slope.

Storage provision 1 no. Wooden Cabinet

Provision for Power Connection The seller to be liable to get the


Electric connection through 3 core
insulated underground cable covered
with MS pipe from the power supply
point provided by the Buyer.

Wiring Concealed wiring

Provision for Cable , Switches and Seller to make appropriate provisions


Junction box connection for cable laying - installing meter /
junction box with switches - other
related electrical accessories as may
be require for the power supply to
the Cabin.

Other requirements All necessary required permissions


from civic agencies for installation
and commissioning to be arranged
by seller - necessary assistance /
documents required to be provided
by Buyer.

Side wall panel material 1.25 mm thick corrugated HR sheet

Door panel material Flush door 32 mm thick water proof.

Window panel material Powder coated aluminium sliding


windows with 4 mm tinted Glass

Door and Window canopy material Fibreglass Reinforced plastics (F.R.P).

Floor panels material 24 mm Block board thickness with


FRP coating checkers style.

Roof panel material Fibreglass Reinforced plastics (F.R.P)

Insulation material for sides and With 50 mm thick glass wool


End walls

Insulation material for Roof With 75 mm thick glass wool

Inside panel material for sides, end Consists of 8 mm thick pre-laminated


walls & roof board.

Roof frame Made of MS having stiffner Top 40


mm x 20 mm x 3.2 mm thick

Side Panel frame Made of MS having stiffner Top 40


mm x 20 mm x 3.2 mm thick

Floor panel frame MS having 50 mm x 50 mm x 1.2 mm

Ask GeMmy Inside Length ± 15 mm 1220 mm

Inside Width ± 15 mm 1065 mm


Total Height (mm) ± 15mm 2135 mm

Roof projection (if any) ± 10 mm 305 mm to be given on all sides at full


height of cabins.

Total thickness of Wall panel ± 2 75 mm


mm

Total thickness of Door panel ± 2 40 mm


mm

Roof ridge height ± 10 mm Total height (i.e. height of side


panels) + 610 mm

Almirah / Cabinet size ± 5 mm 760 mm x 405 mm x 750 mm

Electric fittings Only electric points to be provided


for one fan - One light - One
bulkhead fitting point - one 5 amp.
power point with Switch board
including Double pole MCB 20A with
metal enclosure - continuous earth
wires to be provided and also
external earth terminal to be
provided.

Number of Windows 1 no. window

Roof ridge To be made out from 0.45 mm thick


PPGI sheet.

Flashing item (U track, L corner etc) To be made out with 0.45 mm thick
PPGI sheet in require size and shape.

Locking / Security Cabin have to be provision of locking


Door and Windows to prevent
unwanted intrusion and theft.

Colour White

Top coat Chlorinated rubber paint 50 microns.

Paint outside Two coats of synthetic enamel paint


to be applied on expose structure
and all MS items after installation.

Inside finish Internal panels - doors - ceiling -


shutter to be white finish (excluding
polycarbonate / acrylic glass sheet
and aluminium frames on windows)

Logo (if any) Approved logo of desired size to be


painted as per Buyer's requirement.

Test reports to be furnished to Yes


buyer's on demand

OEM of offered product is ISO Yes


9001:2015 certified

OEM of offered product is ISO Yes


14001:2015 certified

OEM of offered product is ISO Yes


18001:2007 certified

VIEW LESS

GENERIC

Configuration of Cabin With one Room and Verandah.

Transportations / Freight charges Offer Prices are on Free Delivery at


Consignee site basis.
Ask GeMmy
Approval of Advance sample After award of contract - Seller Insulation of Wall / Roof / door Insulation core of panel to be
shall have to get proto type panels formed in one piece and provides
Advance sample approved from desired structural and physical
Buyer before manufacturing / properties.
starting Bulk supplies - Buyer shall
approve / provide list of Ventilation 1 no. ventilator - made out of
modifications required within 10 Aluminium adjustable Louvers
days of offer of advance sample - If type channel and to be fixed in
there is delay in approval of wall panel with suitable fastners.
advance sample from Buyer side -
the delivery period shall be
regularized for the period of delay Storage provision 1 no. Wooden Cabinet
in sample approval.
Provision for Power Connection The seller to be liable to get the
Foundation for Cabin Building of Foundation at site shall Electric connection through 3 core
be the responsibility of the insulated underground cable
Consignee and the Seller shall covered with MS pipe from the
Install / Erect and Commission the power supply point provided by
structure on the foundation the Buyer.
constructed upto plinth level by
the Consignee. Wiring Concealed wiring

Special Condition Scope of supply includes Supply Provision for Cable , Switches and Seller to make appropriate
and Erection of Cabin at consignee Junction box connection provisions for cable laying -
site hence Offer Price to include all installing meter / junction box with
these cost components. Further switches - other related electrical
Offer Prices are on Free Delivery at accessories as may be require for
Consignee site basis hence the power supply to the Cabin.
Transportation / Freight charges
are to be included in Offer price.
Other requirements All necessary required permissions
Building of Foundation at site shall
from civic agencies for installation
be the responsibility of the
and commissioning to be arranged
Consignee and the Seller shall
by seller - necessary assistance /
Erect the structure on the
documents required to be
foundation constructed upto plinth
provided by Buyer.
level by the Consignee. In case
advance sample is required - after
award of contract - Seller shall Completeness of the work Any fittings or items which may not
have to get Advance sample be specially mentioned in the
approved from Buyer before specifications but which are
manufacturing / starting Bulk necessary for commissioning of
supplies. Buyer shall approve / Cabin are to be provided by the
provide list of modifications Seller without any extra charge.
required within 10 days of offer of
advance sample. If there is delay in Electricity charges Charges applicable for obtaining
approval of advance sample from Power connection and recurring
Buyer side - the delivery period monthly power consumption
shall be regularized for the period charges levied by sevice provider
of delay in sample approval. to be borne by Buyer / user
depatment.
Time period for completion of Within 20 days of the date of
Erection work at site by seller receipt of consignee's confirmation
regarding completion of ground PANEL MATERIAL
and foundation work
Side wall panel material 1.25 mm thick corrugated HR sheet
Suitability / structural stability / In wind condition of 55m/s - in
completness of structures, the Seismic zone V and ambient Door panel material Flush door 32 mm thick water
structure is intended for use in temperature range (-) 40 degree C proof.
to (+) 50 degree C - 1 M snow load
standing on the roof - Roof slope 1
Window panel material Powder coated aluminium sliding
: 2 Cabin should be structurally
windows with 4 mm tinted Glass
stable and suitable to meet
severity of these climatic condition.
Door and Window canopy material Fibreglass Reinforced plastics
(F.R.P).
Shape of Cabin Round

Floor panels material 24 mm Block board thickness with


Type of slope(roof) One way slope.
FRP coating checkers style.
Ask GeMmy
Roof panel material Fibreglass Reinforced plastics Roof projection (if any) ± 10 mm 305 mm to be given on all sides at
(F.R.P) full height of cabins.

End panel material 1.25 mm thick corrugated HR sheet Total thickness of Wall panel ± 2 mm 75 mm

Insulation material for sides and End With 50 mm thick glass wool Total thickness of Door panel ± 2 mm 40 mm
walls
Roof ridge height ± 10 mm Total height (i.e. height of side
Insulation material for Roof With 75 mm thick glass wool panels) + 610 mm

Inside panel material for sides, end Consists of 8 mm thick pre- Almirah / Cabinet size ± 5 mm 760 mm x 405 mm x 750 mm
walls & roof laminated board.
Verandah size 1800 mm x 1800 mm

FRAME MATERIAL
MISCELENIOUS
Roof frame Made of MS having stiffner Top 40
mm x 20 mm x 3.2 mm thick Number of Door hinges Hint : For 2 nos.
each Door
Side Panel frame Made of MS having stiffner Top 40
mm x 20 mm x 3.2 mm thick Number of Door handles Hint : For 2 nos. (1 no. each inside and
each Door outside)
Floor panel frame MS having 50 mm x 50 mm x 1.2
mm Number of Tower bolt Hint : For each 1 nos.
Door
Window panel frame Aluminium glazed sliding window
anodized sections frame Number of Aldrop on each door 1 nos.

Understructure / Base Made up of MS pipe 50 mm x 50 safety Grills (for windows) Made from MS square bar of 8 mm
mm x 1.2 mm thick for vertical and having equal spacing of 125 mm
beside - Centre block and outer
ride with 25 mm x 25 mm x 2 mm
thick MS pipe Position of door On one of the longer side

Door panel frame Made of aluminium powder coated Electric fittings Only electric points to be provided
frame. for one fan - One light - One
bulkhead fitting point - one 5 amp.
power point with Switch board
including Double pole MCB 20A
Dimensions and Thickness with metal enclosure - continuous
earth wires to be provided and
Inside Length ± 15 mm 1220 mm also external earth terminal to be
provided.
Inside Width ± 15 mm 1065 mm
Number of Doors 1
Total Height (mm) ± 15mm 2135 mm
Number of Windows 1 no. window
Size of Window ± 10 mm 760 mm x 915 mm
Doors / Windows (against water To be sealed by using rubber
Door Width ± 5 mm 760 mm ingress in closed condition) gasket profiles.

Door Height ± 10 mm 1830 mm Roof slope 1 : 4 (approx) Self Draining Type

Size of Door handle SS 304 Latch 200mm Door opening External

Size of Tower bolt SS 304 125 mm Roof ridge To be made out from 0.45 mm
thick PPGI sheet.

Size of Aldrop 200 mm x 16 mm of SS 304


Flashing item (U track, L corner etc) To be made out with 0.45 mm
thick PPGI sheet in require size and
Size of door hinges 100 mm of SS 304
shape.

Size of Door / Window Chajja 455 mm wide 45 degree slope


(projection if any) ± 10 mm
Ask GeMmy
Locking / Security Cabin have to be provision of WARRANTY
locking Door and Windows to
prevent unwanted intrusion and Guarantee / Warranty of bought out OEMs guarantee /warranty of all
theft. components Bought out components to be
extended to the user unit - Seller
have to submit related documents
Overall covered area by Roof ± 10 3050 mm x 3960 mm
to the Buyer alongwith supply of
mm
Goods.

Service Maintenance Replacements / repairs to be


COLOUR AND FINISH
borne by the seller in respect of
fittings and fixtures during
Colour White
guarantee / warrantee period.

Top coat Chlorinated rubber paint 50


Warranty 1 - Year
microns.

Paint outside Two coats of synthetic enamel


CERTIFICATION
paint to be applied on expose
structure and all MS items after
Test reports to be furnished to Yes
installation.
buyer's on demand

Inside finish Internal panels - doors - ceiling -


OEM of offered product is ISO Yes
shutter to be white finish
9001:2015 certified
(excluding polycarbonate / acrylic
glass sheet and aluminium frames
on windows) OEM of offered product is ISO Yes
14001:2015 certified

Logo (if any) Approved logo of desired size to be


painted as per Buyer's OEM of offered product is ISO Yes
requirement. 18001:2007 certified

Product Compare Product History 1

WEB INFO ABOUT GeM

Terms of Use Introduction to GeM

Website Policies Statistics

Document Help Right to Information

Sitemap Analytics

Web Information Manager New on GeM

BRAND GeM

NEWS & EVENTS RESOURCES

Newsroom GeM Handbook

Gallery OM’s/Circulars

Notifications Terms and Conditions

CCM Schedule Policies/Manuals

Forums Miscellaneous

TESTIMONIALS MOU'S

TRAINING NEED HELP ?

LMS FAQs

Ask GeMmy Training Calendar Feedback

Training Module Raise a Ticket


Facilitators Contact Us

Download GeM Logo Careers

 
 

© 2021 GeM All rights reserved Site operated and maintained by Managed Service Provider

Ask GeMmy

You might also like