No.

Indicator/Button Description Remarks


2288H V6 Server Quick Start Guide
down the OS as prompted.
Document Issue: 04 (2023-04-14) BOM: 31500GSQ (2/3) ⚫ When the device is powered on, you can
xFusion Digital Technologies Co., Ltd. hold down this button for 6 seconds to
forcibly power off the device.
Copyright © xFusion Digital Technologies Co., Ltd. 2023. All Rights Reserved. ⚫
No part of this document may be reproduced or transferred in any form or by any means without prior written consent of xFusion Digital
When the power indicator is steady yellow,
Technologies Co., Ltd. you can press this button to power on the
and other xFusion trademarks are trademarks of xFusion Digital Technologies Co., Ltd. device.
All other trademarks or trade names mentioned in this document are the property of their respective holders.
In this document, "xFusion" is used to refer to "xFusion Digital Technologies Co., Ltd." for concise description and easy understanding, which 3 Health status ⚫
For details about
Off: The device is powered off or is faulty.
does not mean that "xFusion" may have any other meaning. Any "xFusion" mentioned or described hereof may not be understood as any
meaning other than "xFusion Digital Technologies Co., Ltd.", and xFusion Digital Technologies Co., Ltd. shall not bear any liability resulting
indicator how to handle
from the use of "xFusion". ⚫ Blinking red at 1 Hz: A major alarm has alarms, see
All other trademarks or trade names mentioned in this document are the property of their respective holders.
been generated on the system. FusionServer
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to 1 Fault diagnosis LED 2 Power button/indicator Rack Server
ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any
kind, either express or implied. 3 Health status indicator 4 UID button/indicator ⚫ Blinking red at 5 Hz: A critical alarm has iBMC Alarm
5 FlexIO card presence indicator 6 Drives been generated on the system. Handling.
1 Introduction 7 (Optional) Built-in DVD drive (or LCD
module)
8 Slide-out label plate (with an SN label)
⚫ Steady green: The device is operating
FusionServer 2288H V6 (2288H V6) is a new-generation 2U 2-socket rack server designed for properly.
Internet, Internet Data Center (IDC), cloud computing, enterprise, and telecom service applications. 4 UID The UID button/indicator helps identify and None
The 2288H V6 is ideal for IT core services, cloud computing, virtualization, high-performance button/indicator locate a device.
computing, distributed storage, big data processing, enterprise or telecom service applications, and UID indicator:
other complex workloads.
The following table lists the 2288H V6 technical specifications. For details, see FusionServer 2288H ⚫ Off: The device is not being located.
V6 Server User Guide. ⚫ Blinking or steady blue: The device is
Item Specification being located.
UID button:
Dimensions (H x W x D) 86.1 mm x 447 mm x 790 mm (3.39 in. x 17.60 in. x 31.10 in.) ⚫ You can control the UID indicator status by
pressing the UID button or using the
⚫ Operating temperature: 5°C to 45°C (41°F to 113°F) (ASHRAE iBMC.
1 I/O module 1 2 Data transmission status indicator for the
Classes A1 to A4 compliant) management network port ⚫ You can press this button to turn on or off
⚫ 3 Connection status indicator for the 4 PCIe slot 1 the UID indicator.
Storage temperature (within three months): –30°C to +60°C (–
management network port
22°F to +140°F) ⚫ You can press and hold down this button
5 PCIe slot 2 6 PCIe slot 3
⚫ Storage temperature (within six months): –15°C to +45°C (5°F to 7 PCIe slot 4 8 I/O module 3 for 4 to 6 seconds to reset the iBMC.
Temperature 9 Socket for PSU 2 10 Indicator for PSU 2
113°F) 5 FlexIO card None
11 PSU 2 12 Socket for PSU 1 Indicates whether the FlexIO card is
presence
⚫ Storage temperature (within one year): –10°C to +35°C (14°F to 13 Indicator for PSU 1 14 PSU 1 indicator detected.
95°F) 15 Management network port 16 UID indicator ⚫ Off: The FlexIO card is not detected.

17 Serial port indicators (reserved) 18 Serial port
Maximum rate of temperature change: 20°C (36°F) per hour, 5°C ⚫ Blinking green at 0.5 Hz: The FlexIO card
19 USB 3.0 ports 20 FlexIO card
(9°F) per 15 minutes NOTE is detected but is not powered on.
The FlexIO card slot supports OCP 3.0 ⚫
⚫ Operating humidity: 8% to 90% Blinking green at 2 Hz: The FlexIO card is
network adapters.
⚫ Storage humidity (within three months): 8% to 85% 21 VGA port - - detected and has just been inserted.
Relative humidity (RH, ⚫ Steady green: The FlexIO card is detected
⚫ Storage humidity (within six months): 8% to 80%
non-condensing)
3 Indicators and Buttons

and the power supply is normal.
Storage humidity (within one year): 20% to 75%
Indicators on the rear panel
⚫ Maximum humidity change rate: 20%/h
Indicators and buttons on the front panel No. Indicator Description Remarks
⚫ Operating altitude ≤ 3050 m (10006.44 ft) No. Indicator/Button Description Remarks 2 Data ⚫ Off: No data is being transmitted. None
 When the server configuration complies with ASHRAE transmission
1 Fault diagnosis ⚫
For details about
Classes A1 and A2 and the altitude is above 900 m ---: The device is operating properly. status indicator ⚫
LED error codes, see Blinking yellow: Data is being transmitted.
(2952.76 ft), the highest operating temperature decreases ⚫ Error code: A component is faulty. FusionServer for the
by 1°C (1.8°F) for every increase of 300 m (984.24 ft). Rack Server management
 When the server configuration complies with ASHRAE network port
iBMC Alarm
Class A3 and the altitude is above 900 m (2952.76 ft), the Handling. 3 Connection None
Altitude ⚫ Off: No data is being transmitted.
highest operating temperature decreases by 1°C (1.8°F) 2 Power Power indicator: None status indicator
for every increase of 175 m (574.14 ft). button/indicator for the ⚫ Blinking yellow: Data is being transmitted.
 When the server configuration complies with ASHRAE ⚫ Off: The device is not powered on. management
Class A4 and the altitude is above 900 m (2952.76 ft), the ⚫ Steady green: The device is powered on. network port
highest operating temperature decreases by 1°C (1.8°F) 10/13 Connection Replace the PSU
for every increase of 125 m (410.10 ft). ⚫ Blinking yellow: The iBMC is starting. The ⚫ Off: No power is supplied.
status indicator if the indicator is
⚫ HDDs cannot be used at an altitude of over 3050 m (10006.44 ft). power button is locked and cannot be for the ⚫ Blinking green at 1 Hz: in any of the
pressed. The iBMC is started in about 1 management  The input is normal, and the server following states:
network port is standby. ⚫
minute, and then the power indicator is Blinking green
 The input is overvoltage or
2 Front and Rear Panels steady yellow. undervoltage.
at 1 Hz after
⚫ Steady yellow: The device is standby.  The PSU is in deep hibernation the server is
Power button: mode. powered on
⚫ Blinking green at 4 Hz: The firmware is ⚫ Steady orange
⚫ When the device is powered on, you can
press this button to gracefully shut down being upgraded online.
the OS. ⚫ Steady green: The power input and output
NOTE are normal.
⚫ Steady orange: The input is normal but
For different OSs, you may need to shut
No. Indicator Description Remarks Tel: 408-791-6466
FCC Compliance Statement ( for products subject to Part 15)
there is no output. This device complies with part 15 of the FCC Rules. Operation is subject to the
NOTE following two conditions: (1) This device may not cause harmful interference, and
The possible causes of no power output are (2) this device must accept any interference received, including interference that
as follows: may cause undesired operation.
⚫ Power supply overtemperature protection
⚫ Power output overcurrent or short-circuit
⚫ Output overvoltage
⚫ Short-circuit protection
⚫ Device failure (excluding failure of all
devices)
16 UID indicator The UID indicator helps identify and locate a None
device.
⚫ Off: The device is not being located. 5 Power-On

Power on the server using any of the following methods:
Blinking or steady blue: The device is being
⚫ If the PSUs are properly installed but not powered on, connect the power module to the
located. external power supply. The server is powered on along with the PSUs.
NOTE ⚫ If the PSUs are properly installed and connected to the external power supply, and the server
You can control the UID indicator status by is in standby state (the power indicator is steady yellow),
 Press the power button on the front panel to power on the server.
pressing the UID button or using the iBMC.  Power on the server using the iBMC WebUI.
Log in to the iBMC WebUI, choose System > Power > Power Control, click Power
On, and click OK.
4 Installation  Power on the server using the iBMC CLI.
Log in to the iBMC CLI, run the ipmcset -d powerstate -v 1 command, and enter y or Y.
 Power on the server using the Remote Virtual Console.
Log in to the Remote Virtual Console. On the KVM screen, click or on the
• Before unpacking and installing the server, wear an ESD wrist strap or gloves to avoid toolbar, select Power On, and click OK.
damage to electrostatic-sensitive parts.
• At least two people are required to place the server horizontally on the guide rails and
push it into the cabinet. 6 Error Codes
Error Code Fault Description Remarks
1. Install the server.
--- The server is operating normally. -
(1) Place the server on the guide rails and push it into the cabinet.
(2) Align the mounting ears on both sides of the server with the mounting bars of the C0X CPU X is abnormal or faulty. X indicates the CPU number.
cabinet, and tighten the captive screws on the mounting ears to secure the server.
XXX indicates the DIMM
XXX DIMM XXX is abnormal or faulty.
number.
The air inlet temperature is out of the -
A00
operating temperature range of the server.
The temperature of CPU X exceeds its X indicates the CPU number.
A0X
normal range.
P0X PSU X is abnormal or faulty. X indicates the PSU number.
X indicates the fan module
F0X Fan module X is abnormal or faulty.
number.
b01 The power supply to the mainboard is -
abnormal.
b02 The RAID controller card is abnormal or -
faulty.
L01 The cable is not securely or correctly -
connected.
E01 The CMOS battery is abnormal. -
HXX The drive in slot XX is abnormal or faulty. XX indicates the drive
number.
2. Connect cables to service and management network ports.
In this table, X is an integer.

7 Follow-up
After a server is powered on, configure the server. For details, see FusionServer 2288H V6
Server User Guide.
3. Connect the power cables.
Obtain the document from https://www.xfusion.com.

8 FCC

Supplier’s Declaration of Conformity (SDoC)

Unique Identifier: trade name: xFusion; product name: Server;


model number: 2288H V6, H22H-06,
FusionServer 2288H V6
Responsible Party- U.S. Contact Information
RAVV, Inc.
1748 Junction Ave, San Jose,
CA95112, United States

You might also like