Professional Documents
Culture Documents
Ryerolle Rho
Ryerolle Rho
EASUN REYROLLE
Plot 98
Sipcot Industrial Estate
Hosur 635126
Tamil Nadu, India
Tel: (++91/4344) 6995
Fax: (++91/4344) 76397
■ RTD input for motor temperature detection setting and interrogation CT2
Motor
PC or PLC
Key 8
1 8 character message 1
2 3 character scale legend
3 Analogue display of motor current 2 Modbus RTU
(1% resolution)
4 Relay type 7
5 IP55 protection
Rho 0 Network Level
6 Membrane keys with tactile feedback
7 6 character parameter display 3 6
8 DIN 43700 96mm enclosure
9 Complete display backlit L1 L1
4 L1
L2 L2
10 16 character display L2
L3 L3 L3 02
5
THE RHO FAMILY OF PROTECTION RELAYS
Rho 3 - High and medium voltage motors
thermal detector (RTD) inputs ■ Stores 500 events & 5 waveform CTÕs 1amp 4
B phase i/p
5 amp 5
records that can be configured to 1amp 6
C phase i/p
Design record starting current 5 amp 7
1amp
■ Status inputs have programmable Earth fault i/p
Expansion PCB
■ Industry standard case independent pickup & drop off timers Core 5 amp
8 x status inputs STATUS
Balance CT * STATUS
INPUT 1
INPUTS 2 - 9
■ Provides high level EMI screening for protection schemes
■ True RMS measurement
M
*Preferred connection using a core balance CT
SCADA
Reydisp analysis
package
Key Sigma1
RS232
(Fibre optic hub)
1 Relay type 1 6
2 Red LED - motor starting
3 Yellow LED - protection starter pickup
7
4 Page-up key
5 Page-down key 8 Fibre optic
2 IEC 870-5-103
6 Green LED protection helathy 9
3 protocol
7 LCD display (backlit)
10
8 Green LED - motor running 4
9 Red LED - relay trip
10 Enter key 5 11
11 Test and reset key - also enables
sub-menu access 12
12 Cancel key 04
Relay 1 Relay 2 Relay 28 Relay 29
THE RHO FAMILY OF PROTECTION RELAYS
Applications
OHMEGA(1st) CC(1st)-DAD
GAMMA CC(2nd)-B3
ARGUS 1 OHMEGA(2nd)
DUOBIAS ARGUS 1/2 ARGUS 1 170-72kV CC-DAD
CC(1st)-DAD 275-220kV
CC(2nd)-B3
550-400kV
550-400kV SOLKOR RF
ARGUS 1/2 Distribution network Industrial complex
DUOBIAS
SUPERTAPP
PRIMARY S/S ARGUS 1
CC(1st)-DAD 66-24kV
66-24kV DUOBIAS
CC(2nd)-B3 GAMMA
DUOBIAS SUPERTAPP M
SUPERTAPP ARGUS 1/2 ARGUS 1
ARGUS 1/2 DUOBIAS
SUPERTAPP 24-11kV
GAMMA DUOBIAS
OHMEGA(1st) DIST DIST ARGUS 1
MICROPHASE(2nd) SUPERTAPP CABLE CABLE
ARGUS 1/2 RING RING
ARGUS1/2 ARGUS 1 ARGUS 1/2
HIGH DENSITY RHO 3 DUOBIAS
24-6.6kV DISTRIBUTION
S/S M
System embedded 7-3kV
550-400kV
generators ARGUS 1
ARGUS 4
ARGUS 2 RHO 3 ARGUS 1
ARGUS 3
CC(1st)-DAD O/HL ARGUS 6 M
CC(2nd)-B3
Transmission 24 - 6.6kV
1.5 CB substation ARGUS 4 440-380V
ARGUS 3 ARGUS 4
O/HL
415V O/HL
415V RHO 0
M
OHMEGA(1st)
OHMEGA(2nd) 440-380V
ARGUS
275-220kV 500-400kV ARGUS 5
06
P8076 Argus Update 25/7/02 12:34 pm Page 1
Tel: ++44 191 401 1111 Fax: ++44 191 401 5575
Website: www.reyrolle-protection.com Email: marketing.acp@vatechuk.com