Specifications
MEASUREMENT CHARACTERISTICS
Technology Principle Molecular sieve as a drying medium
Typical Flow Rate 8 – 12 ACFM, Hydrogen Column regeneration is automated and takes place based
Typical H2 Consumption 360 ft3 (10 meters3) on programmable inlet and outlet dew point levels. The GGD II has a
per Regeneration (Lower hydrogen consumption with secondary, programmable time based regeneration feature, allowing you
Regenex (TM) option) L to set maximum times between regeneration (from 10 to 30 days).
ELECTRICAL CHARACTERISTICS
Contact E/One to arrange a dew point site-evaluation by our Field
Input Voltage 400/480 VAC Three Phase
Input Frequency 50/60 Hz
Service technicians. We’ll sample your hydrogen cooling gas with NIST
Input Power 3,000 Watts traceable portable dew point and hydrogen purity analyzers and then
Inrush Current 3.5A issue a report to site engineering regarding our findings.

Output, Relays 5A @ 250 VAC


5A @ 30 VDC Features and Benefits
100 mA @ 125 VDC
Dew Point High, NO and NC • Increased generator efficiency and reduced downtime
Trouble, NO and NC
Output, Signals 4-20mA current output
• Comprehensive water and contaminant removal
(self-powered)
• Microprocessor controlled
Input Dew Point
Outlet Dew Point • Designed for hazardous location operation
Area Classification Class I, Zone 2, Group IIB + H2
• Self-monitored drying process
MECHANICAL CHARACTERISTICS • Standard electrical actuator
Ambient Temperature 32 F to 125 F (0 C to 52 C)
Maximum Pressure 100 psi • Compact design great for retrofits (29.75" w x 83" h x 38" d)
Overall Dimensions 29.75" w x 83" h x 38" d
Inlet & Outlet Connections 3/4" ANSI Class 150 RF Flanges
Vent Connection 1/2" ANSI Class 150 RF Flange
Alternate Regeneration
Connection 1/4" Compression Fitting