You are on page 1of 12

ANNEX 6

RECOMMENDATION No.12

Title: Upgrade of the test benches of the Avionics section of the ASU’s according to the OEM prescripts.
Testing and Calibrating

ATC 2000
Decoder Module
Project Thusano
5.3.6 Measuring instrument Necessary for Repair and Calibration

Repair and calibration of the transponder ATC 2000 necessitate measuring


instruments of adequate accuracy and should the following instruments no be
available for this purpose, only instrumentation of equivalent accuracy must be
used to ensure that repair, calibration and final testing are in keeping with
requirements

Transponder Test
IFR 1400 A
Set

Oscilloscope Tektronix TDS 3054 C

0-14 Vcc ≥
Power supply
5Amp

Multimeter Any

5.5 Calibrating instructions

5.5.1 The transponder must only be calibrated when the specified values are no
longer attained in final testing, especially after changing semiconductors or
components.
These calibration ¡instructions also contain information regarding setting and
testing all of which is intended to facilitate systematic fault-tracing.
To calibrate the transponder or for trouble + shooting the receiver/decoder module
can be positioned vertical into the servicing position. Carry out final testing after
calibrating (see final testing 5.6).
Unless explicitly stated otherwise, operate the transponder in the ALT mode for all
measurements.

Páge2 de 12
5.5.2 Pulse Diagrams and Voltage Levels
The pulse shapes depicted in the calibration instructions are merely typical, and
also the oscillogram shown merely applied generally for testing and trouble-
shooting, i.e., differences will occur depending on the oscilloscope being used in
addition, voltage levels are given in the modular circuit diagram to facilitate trouble
- shooting.

5.5.4 Testing and Calibrating the Encoder/Power Supply Module

Produce the test setup as per Fig- 5-1 and set the power supply to 14 V.

Fig-5-1.

Páge3 de 12
Mode A/C decoder Control
T3104 (HEF4027BP) Dual JK flip-flop
SWITCH POSITION
1. Adjust the test setup to mode A
interrogation,
2. without P2 pulse
3. At 500 interrogations per second and a
signal level of – 30 dBm.
4. Vert.: 5 V/cm
Horiz: 10 µs/cm.

Páge4 de 12
Mode A decoder channel 1 and 2
T3103. (HEF4528BP). Dual monostable multivibrator

SWITCH POSITION
1. Adjust the test setup to mode A
interrogation,
2. without P2 pulse
3. At 500 interrogations per second and a
signal level of – 30 dBm.

4. Vert.: 5 V/cm
Horiz: 10 µs/cm.
input : - 30 dBm

Páge5 de 12
Mode C decoder channel 1 and 2
T3102. (HEF4528BP). Dual monostable multivibrator

SWITCH POSITION
1. Adjust the test setup to mode A
interrogation,
2. without P2 pulse
3. At 500 interrogations per second and a
signal level of – 30 dBm.

4. Vert.: 5 V/cm
Horiz: 10 µs/cm.
input : - 30 dBm

Páge6 de 12
Mode A decoder channel 1 and 2
T 3109 (HEF4001BP) Quadruple 2-input NOR gate
T 3108 (HEF4071BP) Quad 2-input OR gate

SWITCH POSITION
1. Adjust the test setup to mode A
interrogation,
2. without P2 pulse
3. At 500 interrogations per second
and a signal level of – 30 dBm.

4. Vert.: 5 V/cm
Horiz: 4 µs/cm.
input : - 30 dBm

Páge7 de 12
Mode C decoder channel 1 and 2
T 3107 (HEF4001BP) Quadruple 2-input NOR gate
T 3108 (HEF4071BP) Quad 2-input OR gate

SWITCH POSITION
1. Adjust the test setup to mode C
interrogation,
2. without P2 pulse
3. At 500 interrogations per second and a
signal level of – 30 dBm.

4. Vert.: 5 V/cm
Horiz: 10 µs/cm.
input : - 30 dBm

Páge8 de 12
GATING GENERATOR AND SLS GATE THE GENERATOR
T 3105 (HEF4528BP). Dual monostable multivibrator

1. Adjust the test setup to mode A


interrogation,
2. without P2 pulse
3. At 500 interrogations per second and a
signal level of – 30 dBm.

4. Vert.: 5 V/cm
Horiz: 4 µs/cm.
input : - 30 dBm

Páge9 de 12
Reply generator and SLS period generator
T3106 (HEF4528BP). Dual monostable multivibrator
SWITCH POSITION
1. Adjust the test setup to mode C
interrogation,
2. without P2 pulse
3. At 500 interrogations per second
and a signal level of – 30 dBm.

4. Vert.: 5 V/cm
Horiz: 10 µs/cm.
input : - 30 dBm

Páge10 de 12
SUPRESSION GATE
T3131 (MC14572UB) hex functional gate
SWITCH POSITION
1. Adjust the test setup to mode A
interrogation,
2. Adjust transponder mode ALT or
ON
3. without P2 pulse
4. At 500 interrogations per second
and a signal level of – 30 dBm.
5. Vert.: 5 V/cm
Horiz: 4 µs/cm.
input : - 30 dBm

Páge11 de 12
SUPRESSION GATE (Cont)
T3132 (MPS 2369)
T3133 (MPS 3640)
T3134 (MPS 2369)

SWITCH POSITION
1. Adjust the test setup to mode A
interrogation,
2. Adjust transponder mode ALT or
ON
3. without P2 pulse
4. At 500 interrogations per second
and a signal level of – 30 dBm.

5. Vert.: 5 V/cm
Horiz: 4 µs/cm.
input : - 30 dBm

Páge12 de 12