You are on page 1of 32

TechMaster

Lock system for safes

PROGRAMMING AND OPERATING


INSTRUCTIONS
Information about TechMaster ................................................................................................ 4
1. Master Menu........................................................................................................................... 6
1.1. Set Time and Date ..................................................................................................... 6
1.2. Time Lock .................................................................................................................... 7
1.2.1. Time Lock - Add ...................................................................................................... 7
1.2.2. Time Lock - Verify or Delete ................................................................................. 8
1.2.3. Special Events - Add............................................................................................... 8
1.2.4. Special Events – Verify or Delete ......................................................................... 9
1.2.5. Opening Periods - Add ......................................................................................... 10
1.2.6. Opening Periods – Verify or Delete.................................................................... 10
1.3. PC Link ....................................................................................................................... 11
1.4 Manager Management .............................................................................................. 11
1.5 Dynamic Codes .......................................................................................................... 12
2. Manager Menu ..................................................................................................................... 13
2.1. Users Management – Install/Delete/Enable/Disable users ................................ 13
2.2. Time Delay and Open Window .............................................................................. 13
2.3. Variable Time Delay ................................................................................................. 14
2.3.1. Variable Time Delay - Add................................................................................... 14
2.3.2. Variable Time Delay - Verify or Delete .............................................................. 15
2.4. PC Link ....................................................................................................................... 15
3. OVR Manager Menu ............................................................................................................ 16
3.1. Users Management – install/delete/disable user ................................................ 16
4. Change Code Menu ............................................................................................................. 17
4.1. Change Users and OVR Users Code ...................................................................... 17
4.2. Change Manager Code ............................................................................................ 17
4.3. Change OVR Manager Code ................................................................................... 18
4.4. Change Master Code ............................................................................................... 18
5. Time Menu ............................................................................................................................ 19
5.1 Opening Extension .................................................................................................... 19
5.2 Immediate Time Lock ............................................................................................... 20
6. Configuration Menu ............................................................................................................. 20
6.1. Install Locks .............................................................................................................. 21
6.2. Remove Locks ........................................................................................................... 21
6.3. LCD Contrast ............................................................................................................. 22
6.4. Language ................................................................................................................... 22
6.5. Membrane test.......................................................................................................... 22
6.6. System Info ............................................................................................................... 23
7. Opening the Locks ............................................................................................................... 23
7.1. Users (or OVR Users): Opening the lock without Time Delay .......................... 23
7.2. Users (or OVR Users): Opening the lock with Time Delay ................................ 23
7.3. Manager (or OVR Manager): Opening the lock without Time Delay ............... 24
7.4. Manager (or OVR Manager): Opening the lock with Time Delay ..................... 25
7.5. Opening the lock with Dynamic Codes (Dallas key option) ............................... 26
7.6. Opening the lock with Dynamic Codes (PIN option) .......................................... 27
7.7. Dual Mode: Opening the lock without Time Delay ............................................. 27
7.8. Dual Mode: Opening the lock with Time Delay ................................................... 28
8. Shortcuts ............................................................................................................................... 29
9. Optional features ................................................................................................................. 29

IU_TechMaster_02_eng Page 3 of 32
Information about TechMaster
Using your keypad

To power up TechMaster press any key.


To slide the functions of a menu use the slide/change button .
To exit from one function of a menu and go back to the main menu slide the functions
until the last one (“EXIT?”) and confirm with the confirm/enter button .
Automatic power savings: LCD will power-off after 30 seconds of non-operation.

Slide/Change

Confirm/Enter

TechMaster opening and administration codes

Every user (Manager, Standard user or Override) can be a numerical code or a


numerical code + Dallas key.
Master code can be only a numerical code.

Default TechMaster codes

Default code for TechMaster are:


Master 12345678
Manager 123456
OVR Manager 654321
User 2 02–020202
User 3 03–030303
.......... ............
User XY XY–XYXYXY
Configuration Code 505050

Factory code has to be changed, as soon as the system is initiated by the


final user.
Page 4 of 32 IU_TechMaster_02_eng
Penalty

Four consecutive invalid codes initiates four minutes delay period. During this period
LCD will display the message “Penalty” when any operation will be performed.

Programming TechMaster

All the following programming instructions of TechMaster must be intended for only
one lock (this also includes Master and Manager codes). If your TechMaster has
more than one lock you must repeat the instructions for each installed lock.

Multiple Locks

TechMaster can manage up to five locks.

Time Delay

Can be set on each lock.


Delay Period: 0 – 99 minutes; Open Period: 1 – 19 minutes.
Five Time Delays can run at once.

Dallas keys

Can be set on each lock, requires code and key. Available for all Manager and Users
(not available for the Master).
TechMaster only works with Dallas keys coded by Tecnosicurezza.

Low Battery Warning

Long audio and visual signals during opening indicate low battery.

Emergency battery

If your TechMaster is powered by the mains or an internal battery box it is possible to


connect an emergency battery to the keypad in case of sudden blackout: connect a
new 9V ALKALINE battery to the battery connector located at the bottom of the
keypad.

Silent Alarm Signal

Can be set on each lock.

Remote Disable

Can be set on each lock.

IU_TechMaster_02_eng Page 5 of 32
Audit

Each Lock will record last 900 operations with time & date, user and function.

Override Reopening

TechMaster can be set to have Override Reopening option (from 0 to 59 minutes). If


this option is set, it will be possible to reopen the lock overriding Time Delay during
the set value of time. This function is available only after a standard opening
procedure of the lock (after opening with time delay).

Important notes

Simple/trivial codes, which could be easily guessed (1,2,3,4,5,6) have to be


prevented.

Never remove lock cover, this voids the warranty.

1. Master Menu
Power up TechMaster.

MASTER MENU
Press . LCD will display the message: XXXXXXXX

Enter Master code (default code 1-2-3-4-5-6-7-8).

1.1. Set Time and Date

Use this function to change Time and Date.

Power up TechMaster and access the Master Menu. LCD will display SET
the message: TIME AND DATE

08:00 FRI
Press . LCD will display current time and date. 27/01/2006

hh:mm ___
Press to modify Time and Date. DD / MM / YYYY

Page 6 of 32 IU_TechMaster_02_eng
Enter new values for time and date and press to confirm.

1.2. Time Lock

TIME LOCK
Power up TechMaster and access the Master Menu. Press two
times.

1.2.1. Time Lock - Add

Use this function to add Time Lock values.

STANDARD WEEK 1
Power up TechMaster and access the Time Lock menu. Press .

To add Standard week 2 or 3 press one or two times, then

press .

ADD
Press . LCD will display the message:

! hh:mm DAY
Press . LCD will display the current day of the week. " hh:mm

The first is Opening time and the second is Closing time.

Enter Opening and Closing time, then press .

To cancel entered values, press .

! hh:mm DAY
" hh:mm
Press to confirm. LCD will display the next day of the week, and

will propose the same values. Press to confirm or to skip


and change day.

At the end of the week LCD will display the message: END OF LIST
EXIT AND SAVE? ü

Press to save settings or to get back to the first day.

Settings will be saved when will be pressed.


IU_TechMaster_02_eng Page 7 of 32
After saving the settings LCD will display the message: ADD

Press to set more periods (up to 4).

1.2.2. Time Lock - Verify or Delete

Use this function to verify or delete Time Lock values.

STANDARD WEEK 1
Power up TechMaster and access the Time Lock menu. Press .

To verify or delete Standard Week 2 or 3 press one or two

times, then press .

VERIFY OR
Press , LCD will display the message: DELETE

! hh:mm DAY
Press , LCD will display the set values for the first day. " hh:mm

Press to scroll all the set values.

DELETE?
Press to delete the set values. LCD will display the message: ü

Press to confirm or press to exit.

END OF LIST
At the end of the list press .

Time Lock Standard week is an Opening Time Period: the safe door can be opened if you
enter a valid code (for ex. Opening Period from 08:00 to 14:00: the door can be opened from
08:00 to 14:00, but can’t be opened at 16:00).

You can enter four different Time Periods for each day (for ex. MON from 07:00 to 10:00;
from 12:00 to 13:00; from 15:00 to 16:00; from 18:00 to 19:00).

Time Periods will be saved just after confirmation pressing . It is recommended to set
the values with safe door open.

All the Users will be automatically added to their related Time Lock table.

1.2.3. Special Events - Add

Page 8 of 32 IU_TechMaster_02_eng
Use this function to add Special Events values.

STANDARD WEEK 1
Power up TechMaster and access the Time Lock menu. Press .

SPECIAL EVENTS
Press three times.

ADD
Press , LCD will display the message:

" DD/MM/YY hh:mm


Press , LCD will display the message: ! DD/MM/YY hh:mm

The first one is the closing time and date and the second one is the opening time and date.

Enter Closing and Opening time and date, then press to confirm.

If a value for Year is set, this Special Event will cease after that date.
If a value for Year is not set, this Special Event will repeat every year.

To cancel entered values, press .

Repeat this procedure for every Special Event.


Special Events are Closing Periods: the safe’s door can’t be opened during these periods.

Up to 30 Special Events are available for a maximum of nine (9) days each.

1.2.4. Special Events – Verify or Delete

Use this function to verify or delete Special Events values.

STANDARD WEEK 1
Power up TechMaster and access the Time Lock menu. Press .

SPECIAL EVENTS
Press three times.

ADD
Press , LCD will display the message:

VERIFY OR
Press , LCD will display the message: DELETE

" DD/MM/YY hh:mm


Press , LCD will display the first saved Special Event. ! DD/MM/YY hh:mm

IU_TechMaster_02_eng Page 9 of 32
Press to scroll all the set values.

DELETE?
Press to delete the set values. LCD will display the message: ü

Press to delete the LCD values or press to exit.

END OF LIST
At the end of the list press .

1.2.5. Opening Periods - Add

Use this function to add Opening Periods values.

STANDARD WEEK 1
Power up TechMaster and access the Time Lock menu. Press .

OPENING PERIODS
Press four times.

ADD
Press . LCD will display the message:

! DD/MM/YY hh:mm
Press . LCD will display the message: " DD/MM/YY hh:mm

The first one is the opening time and date and the second one is the closing time and date.

Enter Opening and Closing time and date, then press to confirm.

If a value for Year is set, this Opening Period will cease after that date.
If a value for Year is not set, this Opening Period will repeat every year.

To cancel entered values, press .

Repeat this procedure for every Opening Period.

During Opening Periods it will be possible to open the safe’s door even if Time Lock is active.

Up to 30 Opening Periods are available for a maximum of nine (9) days each.

1.2.6. Opening Periods – Verify or Delete

Use this function to verify or delete Opening Periods values.

Page 10 of 32 IU_TechMaster_02_eng
STANDARD WEEK 1
Power up TechMaster and access the Time Lock menu. Press .

OPENING PERIODS
Press four times.

ADD
Press , LCD will display the message:

VERIFY OR
Press , LCD will display the message: DELETE

! DD/MM/YY hh:mm
Press , LCD will display the first saved Opening Period. " DD/MM/YY hh:mm

Press to scroll all the set values.

DELETE?
Press to delete the set values. LCD will display the message: ü

Press to delete the LCD values or press to exit.

END OF LIST
At the end of the list press .

1.3. PC Link

Use this function to start the communication between TechMaster and PC (audit, settings).

Power up TechMaster and access the Master Menu. PC LINK

Press two times. LCD will display the message:

PC LINK
Press to start the communication with the PC. ACTIVE . . . . .

Press at the end of the operation, to close the communication.

1.4 Manager Management

Depending on lock configuration this menu could not be available

Use this function to add, disable or delete Manager, OVR Manager and Remote Manager.

IU_TechMaster_02_eng Page 11 of 32
Power up TechMaster and access the Master Menu. MANAGERS
MANAGEMENT
Press three times. LCD will display the message:

1: MANAGER ü
Press . LCD will display the message: 2: OVR MANAGER
ü

01 ü T1
Select the Manager entering his number and press to confirm. DISABLE?
LCD will display the message:
01 ü T1
Press to select the operation: enable, disable, delete or exit and DELETE?

press to confirm.

OPERATION
Press to confirm. LCD will display the message: DONE

1.5 Dynamic Codes

Depending on lock configuration this menu could not be available

Use this function to enable or disable the use of Dynamic Codes on the lock.
Power up TechMaster and access the Master Menu. DYNAMIC
CODES
Press four times. LCD will display the message:
STATUS:
Press . LCD will display the actual status: DISABLED/ENABLED

STATUS:
Press . LCD will display the message: ENABLE?/ DISABLE?

OPERATION
Press to confirm. DONE

If you want to disable the use of Dynamic Codes from all the locks STATUS:
REMOVE FROM ALL
press until LCD will display the message:

OPERATION
Press to confirm and remove the use of Dynamic Codes from all DONE
the locks.

If the use of Dynamic Codes has been removed and you want to activate it again, be sure
Dynamic Code option is enabled on the lock and use the Red Dallas and the key activation
code generated by the software to activate the function.

Page 12 of 32 IU_TechMaster_02_eng
2. Manager Menu
Power up TechMaster.

MANAGER MENU
Press and then press . LCD will display the message: XXXXXX

Enter Manager code (default code 1-2-3-4-5-6).

2.1. Users Management – Install/Delete/Enable/Disable users

Use this function to install, delete, enable or disable or disable Users on the lock.

Power up TechMaster and access the Manager Menu. USERS


MANAGEMENT
Press . LCD will display the message:

01 02 03 04
Press to check the list of Users or enter a User ID to select a ü ü ü ü
user.

01 ü T1
Press . LCD will display the message: DISABLE?

Press to confirm, or press to install/delete/disable/enable

and press to confirm. To skip to the following user, press


when LCD displays the message “Next?”.

LCD symbols meaning xx ü T1


DISABLE?
xx User ID
ü User installed
x User disabled
User with 6 digits code
T1 User following time lock table number 1
User following variable time delay
User with Dallas key

2.2. Time Delay and Open Window

Use this function to set, modify or verify Time Delay and Open Window values.

Power up TechMaster and access the Manager Menu. T. DELAY AND


O. WINDOW
Press . LCD will display the message:

IU_TechMaster_02_eng Page 13 of 32
T. DELAY 00
Press to confirm. LCD will display current values for time delay O. WINDOW 01
and open window.

T. DELAY mm
Press to exit or to set new values. O. WINDOW mm

VALUES
Enter new values for Time Delay and Open Window and press UPDATED
to confirm. LCD will display the message:

Accepted values are: 00÷99min for Time Delay and 01÷19min for Open Window.

To set a lower Time Delay value than the currently set on the lock, the lock must be opened.
If the lock is closed it won’t accept the new entered values. Open the lock and then set new
Time Delay values.

2.3. Variable Time Delay

Depending on lock configuration this menu could not be available

Power up TechMaster and access the Manager Menu. VARIABLE


TIME DELAY
Press two times. LCD will display the message:

2.3.1. Variable Time Delay - Add

Use this function to add Variable Time Delay values.

Power up TechMaster and access the Variable Time Delay menu. ADD

Press . LCD will display the message:

Press . LCD will display the current day of the week.

Enter values for starting time and ending time in which Variable Time
Delay will be active and then enter the values of Variable Time Delay.

Press to confirm. LCD will display the next day of the week, and

will propose the same values. Press to confirm or to skip


and change day.

At the end of the week LCD will display the message: END OF LIST
EXIT AND SAVE? ü
Page 14 of 32 IU_TechMaster_02_eng
Press to save settings or to get back to the first day.

To add Variable Time Delay values, the lock must be opened. If the lock is closed it will be
not possible to access the function. Open the lock and then set Variable Time Delay values.

Variable Time Delay always have to be increased or decreased in steps of 10 minutes from
the value of Time Delay (2.2.). If not, TechMaster will automatically adjust values to the next
available ones.

After saving the settings LCD will display the message: ADD

Press to set more periods (up to 4).

2.3.2. Variable Time Delay - Verify or Delete

Use this function to verify or delete Variable Time Delay values.

Power up TechMaster and access the Variable Time Delay menu.

Press .

VERIFY OR
Press , LCD will display the message: DELETE
08:00 SUN
Press , LCD will display the set values for the first day. 10:00 : 01

Press to scroll all the set values.

DELETE?
Press to delete the set values. LCD will display the message: ü

Press to delete the LCD values or press to exit.

END OF LIST
At the end of the list press .

2.4. PC Link

Use this function to start the communication between TechMaster and PC (audit, settings).

Power up TechMaster and access the Manager Menu. PC LINK

Press three times. LCD will display the message:

PC LINK
Press to start the communication with the PC. ACTIVE . . . . .
IU_TechMaster_02_eng Page 15 of 32
Press at the end of the operation, to close the communication.

3. OVR Manager Menu


Depending on lock configuration this menu could not be available

Power up TechMaster.

OVR MANAGER MENU


Press and then press two times. LCD will display the XXXXXX
message:

Enter OVR Manager code (default code 6-5-4-3-2-1).

3.1. Users Management – install/delete/disable user

Depending on lock configuration you could find this menu inside Master menu or
inside Manager menu

Use this function to install, delete, enable or disable or disable OVR Users on the lock.

Power up TechMaster and access the OVR Manager Menu. USERS


MANAGEMENT
Press . LCD will display the message:

50 51 52 53
Press to check the list of OVR Users or enter a OVR User ID to ü ü ü ü
select a user.

52 ü T1
Press . LCD will display the message: DISABLE?

Press to confirm, or press to install/delete/disable/enable

and press to confirm. To skip to the following user, press


when LCD displays the message “Next?”.

LCD symbols meaning xx ü T1


DISABLE?
xx User ID
ü User installed
x User disabled
User with 6 digits code
Page 16 of 32 IU_TechMaster_02_eng
T1 User following time lock table number 1
User following variable time delay
User with Dallas key

4. Change Code Menu


Personal data (like birthday) or other data which could be easily concluded with
some knowledge about the end user have to be prevented. After changing the code,
the lock has to be checked several times with open door.

Power up TechMaster.

CHANGE
Press and then press three times. LCD will display the CODE
message:

4.1. Change Users and OVR Users Code

Use this function to change Users and OVR Users code. Always perform this operation with
the door opened.

Power up TechMaster System and access the Change Code Menu. CHANGE USER
CODE
Press . LCD will display the message:

OLD CODE
Press to confirm. LCD will display the message: XX–XXXXXX
Enter the old code. LCD will display the message: NEW CODE
XXXXXX

Enter the new code. LCD will display the message: CONFIRM CODE
XXXXXX

Confirm the new code.

4.2. Change Manager Code

Use this function to change Manager code. Always perform this operation with the door
opened.

Power up TechMaster System and access the Change Code Menu. CHANGE USER
CODE
Press . LCD will display the message:

CHANGE MANAGER
Press . LCD will display the message: CODE

IU_TechMaster_02_eng Page 17 of 32
OLD CODE
Press to confirm. LCD will display the message: XXXXXX

Enter the old code. LCD will display the message: NEW CODE
XXXXXX

Enter the new code. LCD will display the message: CONFIRM CODE
XXXXXX

Confirm the new code.

4.3. Change OVR Manager Code

Use this function to change OVR Manager code. Always perform this operation with the door
open.

Power up TechMaster System and access the Change Code Menu. CHANGE USER
CODE
Press . LCD will display the message:

CHANGE OVR
Press two times. LCD will display the message: MANAGER CODE

OLD CODE
Press to confirm. LCD will display the message: XXXXXX

Enter the old code. LCD will display the message: NEW CODE
XXXXXX

Enter the new code. LCD will display the message: CONFIRM CODE
XXXXXX
Confirm the new code.

4.4. Change Master Code

Use this function to change Master code. Always perform this operation with the door open.

Power up TechMaster System and access the Change Code Menu. CHANGE USER
CODE
Press . LCD will display the message:

CHANGE MASTER
Press three times. LCD will display the message: CODE

OLD CODE
Press to confirm. LCD will display the message: XXXXXXXX

Enter the old code. LCD will display the message: NEW CODE

Page 18 of 32 IU_TechMaster_02_eng
XXXXXXXX

Enter the new code. LCD will display the message: CONFIRM CODE
XXXXXXXX

Confirm the new code.

5. Time Menu
Power up TechMaster.

TIME
Press and then press four times. LCD will display the MENU
message:

5.1 Opening Extension

Use this function to delay the beginning of Time Lock up to 2 hours more than programmed
Time Lock.

Power up TechMaster and access the Time Menu. USER CODE


XX–XXXXXX
Press . LCD will display the message:

MANAGER CODE
If you hold the Manager code press . LCD will display the XXXXXX
message:

Enter the User code (or enter the Manager code). LCD will display the OPENING
message: EXTENSION

OPENED UNTIL:
Press . If Time lock is programmed, LCD will display the next 12/09 20:30
Time Lock activation time (automatically calculated adding 2 hours to
Time Lock activation time):

Press to confirm.

If you want to enter different values enter new values for time and OPENED UNTIL:
DD/MM hh:mm
date (max. 2 hours), then press to confirm.

If no time lock period is programmed the function can’t be used. LCD TIMELOCK NOT
will display the message: PROGRAMMED

IU_TechMaster_02_eng Page 19 of 32
5.2 Immediate Time Lock

Use this function to start up the Time Lock immediately.

Power up TechMaster and access the Time Menu. USER CODE


XX–XXXXXX
Press . LCD will display the message:

MANAGER CODE
If you hold the Manager code press . LCD will display the XXXXXX
message:

Enter the User code (or enter the Manager code). LCD will display the OPENING
message: EXTENSION

IMMEDIATE
Press . LCD will display the message: TIME LOCK

CLOSED UNTIL:
Press . If Time lock period is programmed, LCD will display the 14/09 08:00
next Time Lock opening period:

Press to confirm.

If you want to enter different values enter new values for time and CLOSED UNTIL:
DD/MM hh:mm
date (max. 2 weeks), then press to confirm.

If no time lock period is programmed it will be only possible to enter CLOSED UNTIL:
new values: enter new values for time and date (max. 2 weeks), then DD/MM hh:mm

press to confirm.

6. Configuration Menu
Power up TechMaster.

CONFIGURATION
Press and then press five times. LCD will display the XXXXXX
message:

Enter Configuration code (default code 5-0-5-0-5-0).

Page 20 of 32 IU_TechMaster_02_eng
6.1. Install Locks

Use this function to install up to five locks on TechMaster keypad.

Power up TechMaster and access the Configuration Menu. LCD will INSTALL
display the message: LOCKS

SELECT
Press and select the lock to install. LOCK=

If lock is already installed, LCD will display the message: LOCK ALREADY
INSTALLED

If lock is not connected to the keypad, LCD will display the message: LOCK X
DOES NOT ANSWER

If the selected lock is connected, LCD will display the message: MASTER CODE
XXXXXXXX

LOCK X
Enter Master code or press if the Master code is the default INSTALLED
code (1 2 3 4 5 6 7 8). LCD will display the message:

6.2. Remove Locks

Use this function to remove locks from TechMaster keypad.

Power up TechMaster and access the Configuration Menu. LCD will INSTALL
display the message: LOCKS

REMOVE
Press . LCD will display the message: LOCKS

SELECT
Press and select a lock to remove. LOCK=

If lock is connected, LCD will display the message: REMOVE


LOCK 2?

MASTER CODE
Press to confirm. LCD will display the message: XXXXXXXX

Enter Master code. LCD will display the message: LOCK X


REMOVED

If lock is not installed, LCD will display the message: LOCK IS


NOT INSTALLED

If lock is not connected to the keypad, LCD will display the message: LOCK X
DOES NOT ANSWER
IU_TechMaster_02_eng Page 21 of 32
Then the following message will be displayed: CONTINUE?

LOCK X
Press to confirm. REMOVED

Always keep the lock connected during removal operations.

Always perform this operation with the door opened.

6.3. LCD Contrast

Use this function to set LCD contrast.

Power up TechMaster and access the Configuration Menu. LCD will INSTALL
display the message: LOCKS

LCD
Press two times. LCD will display the message: CONTRAST

ADJUST CONTRAST
Press . LCD will display the message: X

Enter a contrast level (between 1 and 9) and press to confirm.

6.4. Language

Use this function to set LCD language.

Power up TechMaster and access the Configuration Menu. LCD will INSTALL
display the message: LOCKS

LANGUAGE
Press three times. LCD will display the message:

LANGUAGE
Press . LCD will display the current set language. ENGLISH

Press to change the language and press to confirm.

6.5. Membrane test

Use this function to test TechMaster membrane.

Power up TechMaster and access the Configuration Menu. LCD will INSTALL
display the message: LOCKS
Page 22 of 32 IU_TechMaster_02_eng
MEMBRANE TEST
Press four times. LCD will display the message:

1234567890 ü
Press . LCD will display the message:

Press all the buttons in the displayed order: a double beep indicates
the button is ok, a long beep indicates the button is broken.

6.6. System Info

Use this function to check TechMaster firmware version.

Power up TechMaster and access the Configuration Menu. LCD will INSTALL
display the message: LOCKS

SYSTEM INFO
Press five times. LCD will display the message:

Press to check information.

7. Opening the Locks

7.1. Users (or OVR Users): Opening the lock without Time Delay

Power up TechMaster and select the lock when two or more locks are installed.
LCD will display the message: USER CODE
XX–XXXXXX

Enter a valid user code and insert the Dallas key, if set-up. LCD will OPEN
display the message:

Invalid code will prompt LCD to display the message WRONG CODE

Open the door within 3 seconds.

Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010

7.2. Users (or OVR Users): Opening the lock with Time Delay

Power up TechMaster and select the lock when two or more locks are installed.

IU_TechMaster_02_eng Page 23 of 32
LCD will display the message: USER CODE
XX–XXXXXX

Enter a valid user code and insert the Dallas key, if set-up. LCD will TIME DELAY
display Time Delay counting time: 00:59

Invalid code will prompt LCD to display the message WRONG CODE

STOP DELAY
To abort Time Delay press and then to confirm. COUNTING?

SELECT
To operate with other locks press during Time Delay counting LOCK:

time and then press again.

After Time Delay has elapsed, the LCD will display the Open Window OPEN WINDOW
counting time. 00:01

USER CODE
Press , LCD will display the message: XX–XXXXXX

Enter a valid user code and insert the Dallas key, if set-up. LCD will OPEN
display the message:

Invalid code will prompt LCD to display the message WRONG CODE

Open the door within 3 seconds.

Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010

7.3. Manager (or OVR Manager): Opening the lock without Time Delay

Power up TechMaster and select the lock when two or more locks are installed.

LCD will display the message: USER CODE


XX–XXXXXX

MANAGER CODE
Press to open with Manager code (or press it two times to open XXXXXX
with OVR Manager code), LCD will display the message:

Enter Manager code and insert the Dallas key, if set-up (or OVR OPEN
Manager code and insert the Dallas key, if set-up). LCD will display
the message:
Page 24 of 32 IU_TechMaster_02_eng
Invalid code will prompt LCD to display the message WRONG CODE

Open the door within 3 seconds.

Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010

7.4. Manager (or OVR Manager): Opening the lock with Time Delay

Power up TechMaster and select the lock when two or more locks are installed.

LCD will display the message: USER CODE


XX–XXXXXX

MANAGER CODE
Press to open with Manager code (or press it two times to open XXXXXX
with OVR Manager code), LCD will display the message:

Enter Manager code and insert the Dallas key, if set-up. (or OVR TIME DELAY
Manager code and insert the Dallas key, if set-up). LCD will display 00:59
Time Delay counting time:

Invalid code will prompt LCD to display the message WRONG CODE

STOP DELAY
To abort Time Delay press and then to confirm. COUNTING?

SELECT
To operate with other locks press during Time Delay counting LOCK:

time and then press again.

After Time Delay has elapsed, the LCD will display the Open Window OPEN WINDOW
counting time. 00:01

USER CODE
Press , LCD will display the message: XX–XXXXXX

MANAGER CODE
Press to open with Manager code (or press it two times to open XXXXXX
with OVR Manager code), LCD will display the message:

Enter Manager code and insert the Dallas key, if set-up (or OVR OPEN
Manager code and insert the Dallas key, if set-up). LCD will display
the message:
IU_TechMaster_02_eng Page 25 of 32
Invalid code will prompt LCD to display the message WRONG CODE

Open the door within 3 seconds.

Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010

7.5. Opening the lock with Dynamic Codes (Dallas key option)

Power up TechMaster (select the lock if two or more locks are installed).

LCD will display the message: USER CODE


XX–XXXXXX

Insert the Dynamic User Dallas Key. LCD will display the message: DYNAMIC USER
XXXX

LCD will display the message: DYNAMIC USER


XXX XXX XXX

Enter the Dynamic Code generated by software and press .

Invalid Dynamic code will prompt the LCD to display the message: WRONG
DYNAMIC CODE

If the Dynamic Code is entered 30 minutes before his activation time DYNAMIC CODE
LCD will display the message: BROUGHT FORWARD

If the Dynamic Code is entered 30 minutes after his activation time DYNAMIC CODE
LCD will display the message: EXPIRED

Dynamic Codes must be used respecting the sequence of activation DYNAMIC CODE
time in which they have been created by the software, otherwise the UNUSABLE
last created code will delete all the previous ones (i.e. if three codes
are created and the third one is used before the first and the second
ones, the two first codes will be deleted). LCD will show the message:

Enter the Dynamic Code. LCD will display the message: OPEN

Open the door within 3 seconds.

Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010

Page 26 of 32 IU_TechMaster_02_eng
7.6. Opening the lock with Dynamic Codes (PIN option)

Power up TechMaster (select the lock if two or more locks are


installed).

LCD will display the message: USER CODE


XX–XXXXXX

Press and hold button number 1. LCD will display the message: PIN
XXXX

Enter your four digits PIN. LCD will display the message: DYNAMIC USER
XXX XXX XXX

Enter the Dynamic Code generated by software and press .

Invalid Dynamic code will prompt the LCD to display the message: WRONG
DYNAMIC CODE

If the Dynamic Code is entered 30 minutes before his activation time DYNAMIC CODE
LCD will display the message: BROUGHT FORWARD

If the Dynamic Code is entered 30 minutes after his activation time DYNAMIC CODE
LCD will display the message: EXPIRED

Dynamic Codes must be used respecting the sequence of activation DYNAMIC CODE
time in which they have been created by the software, otherwise the UNUSABLE
last created code will delete all the previous ones (i.e. if three codes
are created and the third one is used before the first and the second
ones, the two first codes will be deleted). LCD will show the message:

Enter the Dynamic Code. LCD will display the message: OPEN

Open the door within 3 seconds.

Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010

7.7. Dual Mode: Opening the lock without Time Delay

Power up TechMaster (select the lock if two or more locks are installed).

LCD will display the message: USER CODE


XX–XXXXXX

Enter a valid user code and insert the Dallas key, if set-up. LCD will 2° USER CODE
display the message: XX–XXXXXX

IU_TechMaster_02_eng Page 27 of 32
Enter a second valid user code and insert the Dallas key, if set-up. OPEN
LCD will display the message

Open the door within 3 seconds.

Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010

7.8. Dual Mode: Opening the lock with Time Delay

Power up TechMaster and select the lock when two or more locks are installed.

LCD will display the message: USER CODE


XX–XXXXXX

Enter a valid user code and insert the Dallas key, if set-up. LCD will TIME DELAY
display Time Delay counting time: 00:59

Invalid code will prompt LCD to display the message WRONG CODE

STOP DELAY
To abort Time Delay press and then to confirm. COUNTING?

SELECT
To operate with other locks press during Time Delay counting LOCK:

time and then press again.

After Time Delay has elapsed, the LCD will display the Open Window OPEN WINDOW
counting time. 00:01

USER CODE
Press , LCD will display the message: XX–XXXXXX

Enter a valid user code and insert the Dallas key, if set-up. LCD will 2° USER CODE
display the message: XX–XXXXXX

Enter a second valid user code and insert the Dallas key, if set-up. OPEN
LCD will display the message

Invalid code will prompt LCD to display the message WRONG CODE

Open the door within 3 seconds.

Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010

Page 28 of 32 IU_TechMaster_02_eng
8. Shortcuts
Use shortcuts to skip the procedure to get into a menu.

Power up TechMaster.

Press and hold the button corresponding to the menu you want to access to.

Available shortcuts are:

= Access to Change User Code function. Press to change Manager, OVR Manager
or Master code.

= Access to PIN Dynamic Codes function.

= Access to Membrane test function.

= Access to System Info function.

= Come back to main menu.

9. Optional features
9.1. Codes Expiry

TechMaster can be set to have automatic Codes’ Expiry (from 1 to 240 months) option.

If this option is set, LCD will display a warning message when a valid CODE WILL EXPIRE IN
code is entered starting from one week before the expiry date. 7 DAYS
When LCD will display this message change your code.

If your code is expired LCD will display the message: CODE


EXPIRED

To change your code is the only function you will be allowed to do.

If your code is expired you will be not allowed to open the lock. Change your code before
operating the lock again.

9.2. Override Reopening

TechMaster can be set to have Override Reopening option (from 0 to 59 minutes). If this
option is set, it will be possible to reopen the lock overriding Time Delay during the set value
IU_TechMaster_02_eng Page 29 of 32
of time. This function is available only after a standard opening procedure of the lock (after
opening with time delay).

Power up TechMaster.

Enter a valid user code. LCD will display time delay counting: TIME DELAY
00:59

After Time Delay LCD will display open window counting: OPEN WINDOW
00:01

Enter a valid user code. LCD will display the message: OPEN

Open the safe door.

Starting from this moment it will be possible, for the value of time set, to close and open
again the lock overriding Time Delay.

Page 30 of 32 IU_TechMaster_02_eng
DICHIARAZIONE CE DI CONFORMITA’
CE DECLARATION OF CONFORMITY

TechMaster: T9530

Con la presente l’Azienda Tecnosicurezza s.r.l. dichiara sotto la propria


responsabilità, che il suddetto prodotto soddisfa per progettazione e costruzione i requisiti delle
direttive di: compatibilità elettromagnetica 2004/108/CE, 2006/95/CE e RoHS 2 2011/65/UE.
La conformità è stata verificata con l’ausilio delle seguenti norme armonizzate:

EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11,


EN 61000-6-1, EN 61000-6-3, EN 60335-1, EN55022, EN55024, EN50130-4

We the Company: Tecnosicurezza s.r.l. declare herewith on our own


responsability that the above-mentioned product meets the requirements of the 2011/65/UE
RoHS 2, 2004/108/CE, 2006/95/CE Electromagnetical Compatibility for what concerns
engineering and contruction. Conformity has been controlled with the aid of the following
harmonized standards:

EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11,


EN 61000-6-1, EN 61000-6-3, EN 60335-1, EN55022, EN55024, EN50130-4

Verona - Italy, 02/01/2013

Franco Miller
Amministratore Unico
Before operating the lock,
please read this manual thoroughly,
and retain it for future reference.

Correct disposal of this product:


(Waste Electrical & Electronic Equipment)

Applicable in the European Union and other European countries


with separate collection systems.

This marking displayed on the product or its literature indicates that


it should not be disposed with other wastes at the end of its
working life. To prevent possible harm to the environment or
human health from uncontrolled waste disposal, please separate
this from other types of wastes and recycle it responsibly to
promote the sustainable reuse of material resources.

Certified ISO 9001 : 2008

TECNOSICUREZZA s.r.l.
Via Cesare Battisti, 276 – 37057 S. Giovanni Lupatoto (VR) – Italy
Tel. +39 045 826 64 70 - Fax +39 045 826 64 69
mail: info@tecnosicurezza.it - web: www.tecnosicurezza.it

You might also like