Water Consumption Entry pressure Water flow Number of


Equipments
(L/min) (bar) (L/s) faces
Boomer M2D #1 180 2 3.0 4
Boomer M2D #2 180 2 3.0 4
Boomer M2D #3 180 2 3.0 4
Boomer M2D #4 180 2 3.0 4
Boltec MC #1 100 2 1.7 3
Boltec MC #2 100
Boter 975 #1 80 2 1.3 3
Boter 975 #2 80 2 1.3 2
Boter 975 #3 80 2 1.3 2
Simba E7C #1 300 2 5.0 6
Simba E7C #2 300 2 5.0 6
Simba E7C #3 300 2 5.0 0
Simba E7C #4 300 2 5.0 0
Jack-Leg #1 40 2 0.7 2
Jack-Leg #2 40 2 0.7 2
Jack-Leg #3 40 2 0.7 0
Jack-Leg #4 40 2 0.7
wash faces after blast - 2 1 11
Underground Diamond drill #1 120 2 1.8 1
Underground Diamond drill #2 120 2 1.8
Shotcrete - 2 1 11
Car-wash - 2 0.5 -
Restrooms - - 0.01 -
2022
Hours per Hours per Hours per Liters per
face (h) shift (h) day (h) day (L)
2.8 11.2 22 241920
2.8 11.2 22 241920
2.8 11.2 22 241920
2.8 11.2 22 241920
3 9 18 108000
0 0 0 0
3 9 18 86400
3 6 12 57600
3 6 12 57600
3.5 21 42 756000
3.5 21 42 756000
3.5 0 0 0
0
2 4 8 19200
2 4 8 19200
2 0 0 0
0
0.166666667 1.83 3.67 13200
12 12 24 155520
0
2 22 44 158400
- - 0 0
- - 24 864
Total (L/d) 3155664

Total (L/s) 36.52


Machine Rock Drill Provider Water Consumption (l/min)
Boomer M2D COP 1838HD+ Epiroc 90 - 120 l/min
Boltec MC COP 1132 Epiroc 60 - 120 l/min
Simba E7C COP 1838MUX+ Epiroc 120 - 360 l/min
Bolter MEM-975 Montabert Drill-Rock HC 50 Maclean 25 - 100 l/min
Jacklegs MWS83F Gardner Denver 25 - 60 l/min
Water Consumption Average (l/min) Entry pressure (bar)
180 6.0 - 10
100 5.0 - 9.0
300 8.0 - depth
80 2
40 2
Manufacturer BOLTEC MC BOOMER M2D SIMBA E7C
Type COP 1132 COP1838HD COP1838MUX
Dimension and weights
Weight kg 75 171 229
Length without shank mm 735 1008 1206
Width, incl.connections mm 291 251 251
Height, total mm 154 (148) 223 257
Profile height mm 77 (74) 88 122
Impact ratings
Max input power to rock drill kW 20 37 31
Max impact power kW 11 23 18
Oil pressure max or range bar 210 250 230
Flow rate l/min 65 83-93 75-92
Impact frequency Hz 100 70 60
Impact energy Nm 110 328 330
Stroke length positions F 1 1
Dampening system
Type of system DD DD DD
Extractor
Type of system N N E
Rotation output
Torque Nm 550 545 440/640/1000
Rotation range rpm 0-500 0-340 0-370/340/215
Oil consumption l/min 60 75 75
Rotation motor
OMP80  (OMS80) OMS100
Type OMS100  (OMS160)
(OMP125) (OMS160)
Max. working pressure bar 140/175/225 175 210
Output at max pressure kW 10 15 20
Torque Nm 240 249 460
Rotation rate rpm 770 1095 810
Flushing flow and pressure
Water flow l/s 1.0 - 2.0 1.5 - 2.0 2.0 - depth
Water pressure - Inlet bar 5.0 - 9.0 6.0 - 10 8.0 - depth
Air pressure bar 10 10 10
Lubricating airflow l/s 3 5 5
Flushing system a/w/sep w/sep a/w/sep
Drill steel
Shank thread mm 28,32 32,38,45 32,28,45
Bit size mm 32-51 38-89 64-89
Diarot/Navigator Y/N Y/Y Y/Y
Soundry information
Type of impact mechanism FU O O
Accumulator press Hi/Lo/Damp bar 80/90 90 100
Number of hoses 7 (8) 8 10
Sound level dB(A) <98 <106 <106
Comments, Reports
Application RB,D,L,B D,T,RB,G B,Q,L
BOLTEC
Suitable drillrig BOOMER SIMBA
BOOMER
10.5 WATER

All water used underground will be treated mine discharge water. This water will be supplied from the existing

Water for mining use will be brought by pipeline to the portal area from the freshwater storage pond located n

Service waterlines will be installed in all development drifts. Initially, the decline may be serviced with a pump a

Mining Equipment: 250 l/min for Jumbos, long hole drills and bolters
Underground Services: 100 l/min for up to 4 active headings
Shotcrete and Paste Fill Plants: 110 m3/day
ill be supplied from the existing reverse osmosis plant and pumped from the discharge water pond to three 30,000 L head tanks locate

shwater storage pond located near the water treatment plant and stored for use in a water header tank. A water line from the portal

e may be serviced with a pump and tank-truck arrangement. The required water for mining is estimated below:
hree 30,000 L head tanks located near the portal entrance. Provision for water reticulation and pressure reduction is allowed for in th

nk. A water line from the portal will be installed in the decline.
re reduction is allowed for in the underground development cost.
AREA

Water Flow mobile equipment


Equipment Gen. Flow (l/min) Gen. Flow (l/s) Qty Utilization (%) Total Flow (l/s)
Jumbo 180 3.0 3 50% 4.5
Bolter 100 1.7 2 70% 2.3
Simba 300 5.0 1 65% 3.3
Total 580.0 9.7 6 10.1
Total flow in the mobile eqipment mine (L/s) 10.1
Estimated mine flow (L/s) 12.0
Total flow in the mine (m3/hr) 22.1
Total flow in the mine (m3/hr) 79.5