You are on page 1of 1

D E F G H H G F E D

A B C
200 E-01 200
8,400

200 200 200 200 200


2,800 1,100 2,400 1,500 Pitch=25 degrees. Approved box profile roofing on
A A 50 by 75mm timber purlins on 50 by 100mm rafter,

200

200

200

200
struts and ties on 50 by 50mm timber wallplate.

750
1,300
200 200 200 300
900 1,000 900

1,500
MASTER BEDROOM
3,200
1,500
BEDROOM

920
S-01 S-01

E-04

E-02
1,300
W/C

610
7,600

7,600
900

320
B B

200

200
200

120
200 200

610
W/C

900
1,700 1,100

900

270
200 100

200
1,500

1,000
LOUNGE KITCHEN

1,200

200
900

900
900
C C

200

200

200

200
1,000

1,000
PORCH 1,700 2,600 1,300 3,000

200 200 300 200 200 200 STRIP FOUNDATION SPECIFICATION


900 600 1,500 2,400 2,100
200 200 600mm wide by 200mm thick RC strip.
8,400
ROOF PLAN SCALE 1:50 Use D10 @200 c/c. Foundation depth to be
E-03
4,300 3,500
determined on site not less than 1000mm
deep strip
H G F E D
D E F G H
A B C SECTION 01 SCALE 1:50
GROUND FLOOR PLAN SCALE 1:50
ELEVATION 04 SCALE 1:50

NOTES
a) All units are in mm unless otherwise started.
D E F G H b) The floor slab is 125 mm thick - Class 15/20
concrete on 1000 gauge polythene on A66 BRC mesh
H G F E D C B A on well compacted hardcore.
c) Report any discrepancies to the relevant persons.
d) Report any changes to the architect before
implementing them.
e) The engineer to inspect the set out works at every
stage.
f) Provide concrete cover of 25 mm on beams and 50
mm for foundation strips/pads.

600
200 600200 800 1,350100 1,150200 200

200300 600200 200


200 300
Inlet Outlet

6000
L SEPTIC PLAN 1:50

3,000 1,300 2,600 1,700


1,700 2,600 1,300 3,000
150
mm cover slab 600
x450
mm cover
Ground level Ground level
Inlet Outlet

500200
Manhole TWL Manhole
3,500 4,300

500
Invert level of incoming drain

1400
1500
200
mm thick
masonry wall
with
10mm
rendering to 10mm waterproofing
approval

D E F G H
H G F E D C B A SEPTIC DETAILS
ELEVATION 03 SCALE 1:50
ELEVATION 02 SCALE 1:50

ELEVATION 01 SCALE 1:50

GSPublisherVersion 0.57.100.100