You are on page 1of 46

Introduction to Vijeo Basic V1.

2
June 11, 2021

Presented by: Joe Xu

Confidential Property of Schneider Electric


Internal
1 Vijeo Designer and Vijeo Basic

2 New Features in Vijeo Basic V1.2

3 Cyber Security enhancement

Agenda 4 HMIGXU Migration

Internal
Vijeo Designer and Vijeo Basic

Confidential Property of Schneider Electric | Page 3


Internal
Difference between Vijeo Designer and Vijeo Basic

Vijeo Basic does not support


1 Vijeo Basic is a Lightweight Version
of Vijeo Designer
5 Webgate

Vijeo Basic does not support Vijeo-


2 Vijeo Basic only supports two HMI 6 connect
families called HMIET6 and HMIGXU

Vijeo Basic is not integrated in the Vijeo Basic only support two
3 Somachine or Machine expert 7 languages: English and Simplified
Chinese

Vijeo Basic does not support Vijeo


4 Air and Vijeo Air+ 8 LMC is not supported in Basic.

Confidential Property of Schneider Electric | Page 4


Internal
Vijeo Basic – Light weight version of Vijeo Designer

Vijeo Basic: installer size 241MB

Vijeo Designer: installer size 4 GB

Confidential Property of Schneider Electric | Page 5


Internal
Vijeo Basic – Supports only two Hardware families

Vijeo Designer V6.2 SP11 Vijeo Basic V1.1 Vijeo Basic V1.2

XBTGT/XBTGC/HMIGTO/GTU series… HMIGXU HMIGXU+ HMIET6

Confidential Property of Schneider Electric | Page 6


Internal
Vijeo Basic – Does not support SoMachine or Machine Expert

SoMachine

Machine Expert

Vijeo Basic

Confidential Property of Schneider Electric | Page 7


Internal
Vijeo Basic – Does not support Vijeo Air and Vijeo Air+

Vijeo Air

Vijeo Air+
Vijeo Basic

Confidential Property of Schneider Electric | Page 8


Internal
Vijeo Basic – Does not support Vijeo WebGate

WebGate

Vijeo Basic

Confidential Property of Schneider Electric | Page 9


Internal
Vijeo Basic – Does not support Vijeo Connect

The Vijeo Connect provides secure remote access to our customers as if you were
on site (allow remote programming just as you are on site to save travel cost and
reduce machine downtime).

Vijeo Basic Vijeo Connect (Secure Connect)

Confidential Property of Schneider Electric | Page 10


Internal
Vijeo Basic – supports only English and Simplified Chinese

English and Simplified Chinese for Build time UI and


Runtime System messages

Confidential Property of Schneider Electric | Page 11


Internal
Installation of Vijeo Designer and Vijeo Basic

Vijeo Vijeo Basic SoMachine Machine Expert


Designer

4 software can be installed on


the same PC.

When installing Vijeo Basic V1.2 on top of V1.1, the V1.1 has to be manually
uninstalled before installing V1.2
Confidential Property of Schneider Electric | Page 12
Internal
Vijeo Basic – Does not support PacDrive LMC(Logic Motion Controller)

Vijeo Basic LMC

Vijeo Basic does not support LMC(Logic Motion Controller), which is Codesys based.

Confidential Property of Schneider Electric | Page 13


Internal
New Features supported in Vijeo Basic V1.2

Confidential Property of Schneider Electric | Page 14


Internal
Substitution Plan

Substitution Plan
Product spec comparison (ET6 versus GXU)

Specifications ET6 series GXU series Specifications ET6 series GXU series
Software Vijeo Desiger Basic V1.2 or above Vijeo Desiger Basic V1.0 or above 7”W W190 x H135 W190 x H135
CPU 800MHz 333MHz
Panel Cut-out 10”W W255 x H185 W255 x H185
7”w: (800 x 480), 10”w: (1024 x 600) 7”w: (800 x 480), (mm)
Size (Resolution) 12”W W295 x H217 n/a
Display 12”w: (1280 x 800), 15”w: (1366 x 768) 10”w: (800 x 480)
Color 16M colors 64K colors 15”W W394 x H250 n/a
Sustainability Backlight Lifetime >= 20K hrs >= 20K hrs 7”W W206 x H151 x D45 W207 x H152.4 x D38.2
DDR memory 256MB 128MB Externa 10”W W271 x H201 x D47 W275 x H206 x D38.2
Dimension
NAND Flash 256MB 128MB (mm) 12”W W311 x H233 x D50 n/a
Main user 15”W W412 x H268 x D50 n/a
Memory 32MB (7”) / 64MB (10”/12”/15”) 32MB
memory
Capability USB ET6 series GXU series
Backup memory 128KB 128KB
Local data storage 32MB on NAND n/a
External storage USB memory stick USB memory stick
1 x RS232 (all models) 1 x RS232 (except SIO model)
SIO Location of
1 x RS422/RS485 1 x RS422/RS485
USB Type A
1 x 10/100Mbps 1 x 10/100Mbps
Connectivity Ethernet
(except SIO Model) (except SIO Model)
1 x USB Type A (except SIO Model) 1 x USB Type A (except SIO Model) on the bottom side On the rear side
USB host / device
1 x USB micro-B 1 x USB mini-B
Operation Temp. 0 – 50 ℃ 0 – 50 ℃ USB Type B
Environmental IP IP65F IP65F download port
Coating default coating default coating
Power Supply 19.2 ~ 28.8Vdc 20.4 ~ 28.8Vdc
LED indicator Yes (booting, standby mode) Yes (booting, standby mode)
Others
Certification CE, UL, KC, EAC CE, UL, KC, EAC

Internal
New HMIET series Target support – True Color

Support two Color Depth: True color


and 64K Colors.

Note: For Projects with plenty of


photos, 64K Color Depth is also
supported to reduce the overall size
of the project.

Confidential Property of Schneider Electric | Page 16


Internal
New HMIET series Target support – SIO ports

Supports two COM ports for all HMIET targets.


HMIGXU3500x/5500x only have one COM port.

COM1: RS-232C COM2: RS-422/RS-485

Confidential Property of Schneider Electric | Page 17


Internal
New HMIET series Target support – New Protocols

Supplier Driver Name PLC Equipment

Generic Drivers BacNet/IP EthernetIP

SIMATIC S7 Ethernet
S7-200 SMART series
Siemens AG
SIMATIC TIA Ethernet S7-1200/1500 Series

Melsec iQRF Ethernet (TCP/UDP) iQRF (Ethernet)

Mitsubishi
Electric L (Ethernet)
Melsec L Ethernet (TCP/UDP)

Note: For SIMATIC TIA Ethernet, only link variable supported.

Confidential Property of Schneider Electric | Page 18


Internal
New HMIET series Target support – Local Data Storage(1)
Runtime data location for Data logging, Alarm&Events now supports local data Storage

Local Storage
(32MB)

Binary
format

Working Memory
(Data Logging, Alarm&Event)

HMI
Confidential Property of Schneider Electric | Page 19
Internal
New HMIET series Target support – Local Data Storage(2)

 Runtime Data Location supports


Main Drive.

 The size allocated for Main


Drive is 32MB.

 USB key is not necessary for


Data logging, Alarm&event
when data size <32MB.

 More Robust due to realtime


NAND file system

HMI
Confidential Property of Schneider Electric | Page 20
Internal
New HMIET series Target support – Local Data Storage(3)

For HMIET6401/6501 with no USB A type, SRAM&File


option for logging, Alarm&Event is enabled now.

HMI
Confidential Property of Schneider Electric | Page 21
Internal
New HMIET series Target support – System Variables to monitor low splace(4)

A New System variable _LowSpaceStatus is added to monitor Low Space for Runtime
Data Location.

HMI
Confidential Property of Schneider Electric | Page 22
Internal
New HMIET series Target support – Copy data To Drive/Data Manager

For HMIET6400/6500/6600/6700
with USB A type, Copy
data(logging, Alarm&Event) from
Main Drive to Optional Drive is
enabled.

For HMIET6401/6501 without USB


A type, Data Manager tool could be
used to retrieve file from Main
Drive

HMI
Confidential Property of Schneider Electric | Page 23
Internal
New HMIET series Target support – Alarm Message Length

The length for Alarm Message is configurable now between 10- 255.

HMI
Confidential Property of Schneider Electric | Page 24
Internal
New HMIET series Target support – NAT(Network Address Translation) support(1)

The Vijeo Designer Runtime can be downloaded to a target machine through a


router.

HMI
Confidential Property of Schneider Electric | Page 25
Internal
New HMIET series Target support – NAT(Network Address Translation) support(2)

HMI
Confidential Property of Schneider Electric | Page 26
Internal
HMIET Performance

Confidential Property of Schneider Electric | Page 27


Internal
New HMIET Performance - Refresh time

Test application configuration


Objects Configuration
Objects Texts(20) | Switchs origin theme parts(5) |
Switchs picture parts(5) | Lamps Theme
parts(20) | Lamps Pictures(20) | Numeric
Display(5) | Pixel 100*100(5)
Alarm 250 for INTs, 250 for BOOLs
Triggered alarm 5 for INTs, 5 for BOOLs
Data logging 40 for INTs
Language 3 Languages

Confidential Property of Schneider Electric | Page 28


Internal
Cyber Security improvement in Vijeo Basic V1.2

Confidential Property of Schneider Electric | Page 29


Internal
Cybersecurity Enhancement – Secured Firmware

Secure Boot

C Firmware Signing

the Firmware authenticity is guaranteed

Confidential Property of Schneider Electric | Page 30


Internal
Cybersecurity Enhancement – California Law Compliant

California Law Compliant

C FTPs Support

Confidential Property of Schneider Electric | Page 31


Internal
California Law Compliant – New Welcome Screen

Added One screen for customer to be aware of the security for network connection.
The ethernet port is disabled before clicking Accept Button.
Legacy welcome screen will show up after clicking Accept Button and download via
Ethernet is enabled.

Confidential Property of Schneider Electric | Page 32


Internal
California Law Compliant – Build time Support(1)

New check box “Allow Ethernet Download&Upload at Run time” added.


Default value for the check box is unchecked, meaning after download the Download Server will be
disabled, no project can be download again anymore without enabling it at runtime.

Confidential Property of Schneider Electric | Page 33


Internal
California Law Compliant – Build time Support(2)

When a user enables check box, the security warning


message popes up as follows:

Confidential Property of Schneider Electric | Page 34


Internal
California Law Compliant – Build time Support(3)

Default value for “To configuration changed from “2 Corner” to “None”

Confidential Property of Schneider Electric | Page 35


Internal
California Law Compliant – Runtime Support

Added new check box “Allow Ethernet


Download&Upload”
Download Server is disabled when the
box is unchecked.

Confidential Property of Schneider Electric | Page 36


Internal
Cybersecurity Enhancement – Achilles Test

Achilles tests verifies the network robustness of industrial


devices

Protocol covered: Ethernet, ARP, IP,


ICMP, TCP, UDP

We are not going to apply for the


Certificate, but Internally HMIET
devices passed Achilles test.

Confidential Property of Schneider Electric | Page 37


Internal
Cybersecurity Enhancement – Penetration Testing

Penetration testing is a cyber attack


simulation against your devices.
The goal of the test is to make sure
the good vulnerability management.

For HMIET Series, all testing items


related to Ethernet connection are
passed.

Confidential Property of Schneider Electric | Page 38


Internal
Cybersecurity Enhancement – FTPs

For HMIET series, the runtime upgrade, project download are


executed via FTPs, which is secured connection.
TLS 1.2 is adopted internally.

Download via FTPs

Confidential Property of Schneider Electric | Page 39


Internal
HMIGXU Migration

Confidential Property of Schneider Electric | Page 40


Internal
HMIGXU Migration – Open V1.1 HMIGXU project

When Opening the V1.1 HMIGXU project, the following dialog box
will pop up.

All the behavior of the project will be kept the same as V1.1.
Confidential Property of Schneider Electric | Page 41
Internal
HMIGXU Migration – V1.1 Hot Fix Merge

The following V1.1 Hot fixes are not merged to the V1.2. If V1.2 installed on top
of the HotFixes below, the issues fixed in the Hotfixes will appear again.

V1.1 HotFix 17:PEP0574772R:VJD Basic-ZR-CN-115200bps for Modbus RTU.


V1.1 HotFix 15: PEP0540199R:VJD BASIC V1.1-SGH-CHINA-Screen keyboard input problem.
V1.1 HotFix 12: PEP0446488R:GXU5512 had occur event error in Xizang
V1.1 HotFix 11: PEP0421447R:VJD Basic-CT-GXU report 22H error when connect with M241 via TCP

Confidential Property of Schneider Electric | Page 42


Internal
HMIGXU Migration – Migration from HMIGXU to HMIET(1)

HMIGXU Hardware Migration:

Serial 7”W HMIGXU3500 Serial 7”W HMIET6401


Model 10”W HMIGXU5500 Model 10”W HMIET6501

Ethernet 7”W HMIGXU3512 7”W HMIET6400


Model HMIET6500
10”W HMIGXU5512 Ethernet 10”W
Vijeo Designer Basic Model 12”W HMIET6600
Software
V1.0 or above 15”W HMIET6700
Vijeo Designer Basic
Software
V1.2 or above

Confidential Property of Schneider Electric | Page 43


Internal
HMIGXU Migration – Migration from HMIGXU to HMIET(2)

HMIGXU3500x / 5500x (Serial model) HMIET6401x / 6501x (Serial model)

COM1 RS-485 in HMIGXU3500x switched to HMIET6401x, need to manually switch to COM2 RS-485

Confidential Property of Schneider Electric | Page 44


Internal
HMIGXU Migration – Migration from HMIGXU to HMIET(3)

HMIGXU5500x/5512x HMIET6501x/6500x
(800x480) (1024x600)

Vijeo Basic newly supports auto resizing function with low resolution upgrading to high resolution.

Confidential Property of Schneider Electric | Page 45


Internal
©2014 Schneider Electric. All Rights Reserved.
All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies or their respective owners.

Internal

You might also like