P-SERIES

SUBMITTAL DATA: PKA-A12HA7 & PUY-A12NKA7


12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM

-RE1DPH (QJLQHHU
3XUFKDVHU $SSOLFDWLRQ 6WG&RROLQJ 8OWUD/RZ$PELHQW&RROLQJ

6XEPLWWHG7R )RU5HIHUHQFH$SSURYDO&RQVWUXFWLRQ
6XEPLWWHG%\ /RFDWLRQ
6\VWHP'HVLJQDWLRQ 6FKHGXOH1R
(OHFWULFDO3RZHU
5HTXLUHPHQWV
93KDVH+]

0LQLPXP&LUFXLW$PSDFLW\ 0&$ * Breaker Size MOCP (Outdoor)


,QGRRU8QLW3.$$+$ ,QGRRU1 AMP Outdoor 11 AMP 15 AMP 28 AMP
*All electrical work shall comply with National (CEC) and local codes and regulations.
2XWGRRU8QLW38<$1.$ %6 ,QGRRU8QLW
UNIT OPTION: )DQ0RWRU (&0 F.L.A. 
6WDQGDUG0RGHO38<$1.$
)DQ0RWRU2XWSXW W 
6HDFRDVW %6 0RGHO38<$1.$%6
6+)0RLVWXUH5HPRYDO SWK
ACCESSORIES:
)LHOG'UDLQSLSH6L]H2' In.(mm)  

&RQWUROV 2XWGRRU8QLW
:LUHOHVV&RQWUROOHU 0+. 
&RPSUHVVRU '&,19(57(5GULYHQ7ZLQ5RWDU\
$GYDQFHG:LUHG&RQWUROOHU 3$50$$ / PAR-33MAA

Should this document be altered or changed without MESCA’s permission, it becomes null and void. MESCA assumes no responsibility for any consequences in such cases.
6LPSOH:LUHG&RQWUROOHU 3$&<7&5$8  )DQ0RWRU (&0 F.L.A. 
:LUHOHVV5HPRWH&RQWUROOHU 3$5)/0$ )DQ0RWRU3RZHU : 
Thermostat Interface (PAC-US444CN)
01(7$GDSWHU 3$&6J19MA-E $LUIORZ5DWH /RZ0LG+L
2XWGRRU8QLW '5< 
,QGRRU
Front Wind Guard (PFR-12-18) &RROLQJ :(7 CFM 
Rear Wind Guard (PRE-12-18)
Side Wind Guard (PSD-12-18) 2XWGRRU '5< 
Note: Mitsubishi Electric (MESCA) supports the use of only MESCA supplied and 6RXQG3UHVVXUH/HYHO
approved Snow Guard / Wind Deflectors / Windscreens and accessories for proper
functioning of the unit(s). Use of non-MESCA supported Snow Guard / Wind ,QGRRU /RZ0LG+L 
Deflectors / Windscreens and accessories will affect warranty coverage. dB(A)
2XWGRRU &RROLQJ 

([WHUQDO'LPHQVLRQV
SPECIFICATIONS:
,QGRRU +[:[' [[
5DWHG&RQGLWLRQV &DSDFLW\,QSXW
[[
In.(mm)
&RROLQJ Btu/h / W  [[
2XWGRRU +[:['
5DWLQJ&RQGLWLRQVSHU$+5,6WDQGDUG [[
&RROLQJ_,QGRRUž) ž& '%ž) ž& :%
&RROLQJ_2XWGRRUž) ž& '%ž) ž& :%
1HW:HLJKW

&DSDFLW\5DQJH ,QGRRU  


Lbs.(kg)
&RROLQJ Btu/h  2XWGRRU  

2SHUDWLQJ5DQJH ([WHUQDO)LQLVK

&RROLQJ 40)  400ž& WRž) ž& '% ,QGRRU :KLWH0XQVHO1R<


2XWGRRU ,YRU\0XQVHOO1R<
** Windscreens required for cooling operation below 23°) (-5°C)
5HIULJHUDQW 5$OEVR] NJ

$+5,(IILFLHQF\5DWLQJ 5HIULJHUDQW3LSLQJ )ODUHG

((5  /LTXLG +LJK3UHVVXUH ()


In.(mm)
6((5  *DV /RZ3UHVVXUH  (1

0D[LPuP7RWDO
5HIULJHUDQW3LSH/HQJWK
Ft. (m)  

0D[LPXP9HUWLFDO
6HSDUDWLRQ
Ft. (m)  
6SHFLILFDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH

‹0LWVXELVKL(OHFWULF6DOHV&DQDGD,QF 3DJHRI )RUP6%B3.$$+$B38<$1.$B908


8QLWLQ PP

15-3/16(387) 7-1/2(192)
Top side

7-3/4(197)
Mount board

23-9/16(599)
Front side Right side

‹0LWVXELVKL(OHFWULF6DOHV&DQDGD,QF
6SHFLILFDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH
11-5/8(295)
A

Left side 9-13/16(249) 3/16(5)


D 2-1/8 27-1/16(688) 6-1/16(155)
(55)
Knock out hole 35-3/8(898)
for left piping Knock out hole
for right piping
Front side(Grille open)
Sleeve Through hole
(purchased locally)

3DJHRI
[2-1/2~[3-1/8 [2-1/2~[3-1/8
([65~[80) ([65~[80)
Terminal block for indoor/outdoor
connecting line

Terminal block for power supply (option)

Terminal block for


MA-remote controller
',0(16,2163.$$+$

17-15/16(457)Gas pipe 6-5/8(169)


Drain hose Emergency operation switch
21-3/16(539)Liquid pipe 6-3/16(158) (cooling/heating)
7-3/16(184)

Under side
Vane(auto) Operation lamp DEFROST/STAND BY lamp
24-1/16(612)

5/16(8)
Refrigerant Liquid pipe 1/4F ([6.35)
Piping
Gas pipe 1/2F ([12.7)
[5/8 ([16) O.D
Knock out hole Drain hose
for lower piping Effective length: 15-3/4 (400)

Louver(manual) Knock out hole Receiver


C for lower piping B

)RUP6%B3.$$+$B38<$1.$B908
Should this document be altered or changed without MESCA’s permission, it becomes null and void. MESCA assumes no responsibility for any consequences in such cases.
Should this document be altered or changed without MESCA’s permission, it becomes null and void. MESCA assumes no responsibility for any consequences in such cases.

8QLWmm (in.)
FOUNDATION BOLTS
Free space around the outdoor unit
Please secure the unit firmly
with 4 foundation (M10<W3/8>) bolts.
(Bolts, washers and nut must (basic example)
be purchased locally).

Outdoor terminal block


<Foundation bolt height> 100mm<3-15/16> or more as long as

Indoor terminal block

ZZZ0LWVXELVKL(OHFWULFFD
no obstacle is placed on the
rear and right-and-left sides
of the unit

Basically open

Power supply
Ground wire

indoor/outdoor
power & control

connecting cable
FOUNDATION

Indoor-Outdoor S2-S3 ................. 24Vdc


Indoor-Outdoor S1-S2 ...... 208/230Vac

Indoor remote controlle.r ................. 12Vdc


Outdoor terminal block
Min.100mm Min.350mm

Max.
18mm<23/32>

‹0LWVXELVKL(OHFWULF6DOHV&DQDGD,QF
<3-15/16> <13-25/32>

6SHFLILFDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH
404.5<15-15/16> drain hole
Air intake ø42 2-U Shaped notched holes
Installation bolt pitch (Foundation Bolt M10<W 3/8>)
500<19-11/16> Min.500mm Min.100mm

48<1-29/32>
<19-11/16> <3-15/16>

2 sides should be open in

330<13>
Air intake the right, left and rear side.

360<14-3/16>

300<11-13/16>

3DJHRI
Air discharge
40<1-19/32>

2-10×21oval hole 23.2<15/16>

32.5<1-9/32>
22.3<29/32> (Foundation Bolt M10 Terminal connection Service panel
<W 3/8>) 22<7/8> for charge plug
Left ... Power supply wiring
DIMENSIONS: PUY-A12N.A

Right ... Indoor/Outdoor wiring


Handle for moving Connection for
liquid pipe FLARE ø6.35 (1/4F)

Earth terminal
Service panel
35°
43°

630 <24-13/16>
492<19-3/8>

2-ø22.2<7/8>

320<12-5/8>
8.5<11/32>
1/2 conduit hole Connection for
gas pipe FLARE ø12.7 (1/2F)
154.5<6-3/32> Service port 185.5<7-5/16>
310<12-7/32>
164.5<6-1/2>
99.5<3-15/16>

809<31-7/8> 62<2-15/32>

)RUP6%B3.$$2H$B38<$21.$B908