You are on page 1of 6

Project : No To Do :

HIGH SECURITY BUILDING


Subject : Sheet no :
Static Calculation 1 of 6
Area : Date : Rev :
Peri UP H: 6.3 m 28 July 2023 -

I. TECHNICAL DATA

Image 1.1 Section View

Image 1.2 Top View


Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 2 of 6
Area : Date : Rev :
Peri UP H: 6.3 m 28 July 2023 -

II. MATERIAL PROPERTIES

UVR/UVH (Ø 48.3 X 3.2 MM) :

Outside diameter 48.3 mm


Inside diameter 45.1 mm
Thickness 3.2 mm
Radius of Gyration of Area (i) 1.6 cm
Modulus of Section 4.8 cm3
Sectional area 4.53 cm2
E 2,100,000 kg/cm2
σ ijin 2,168 kg/cm2

UBL (Ø 42.4 X 2.6 MM) :

Outside diameter 42.4 mm


Inside diameter 39.8 mm
Thickness 2.6 mm
Radius of Gyration of Area (i) 1.41 cm
Modulus of Section 3.05 cm3
Sectional area 3.25 cm2
E 2,100,000 kg/cm2
σ ijin 2,168 kg/cm2

LEDGER UH (TUBE 60 X 30 X 2 MM):

b 0.2 cm
Ax 3.79 cm2
Ix 16.8 cm4
Wx 5.6 cm3
Sx 3.73 cm3
Δ max L/360
E 2,100,000 kg/cm2
σ allowable 2,168 kg/cm2
τ allowable 3,113 kg/cm2
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 3 of 6
Area : Date : Rev :
Peri UP H: 6.3 m 28 July 2023 -

III. LOAD

 Dead Load
Dead Load used is Sefweight material. Selfweight material is weight materials used for formwork (automatically
calculated by Staad Pro)
 Live Load
Live load consisting man power load and activity occurred at the casting. Live load used is 250 kg/m2.
 Wind Load
Wind load is horizontal load for shoring. Wind load used is 78.5 kg/m2.
 Material Spesification
a. For material Peri UP used Steel S355 with yield strength 3,620 kg/cm2 and tensile strength 5,200 kg/cm2
 Load Combination
a. Load combination include Dead Load and Live Load with safety factor 1.67 (for allowable yield and tensile
strength).Method used in analysis is Allowable Stress Design (ASD) Method (SNI 1729-2020)
b. Load Combination = 1 DL + 1 LL + 1 WL
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 4 of 6
Area : Date : Rev :
Peri UP H: 6.3 m 28 July 2023 -

IV. STRUCTURE ANALYSIS


A. Shoring Peri UP Stability Control

Spesification Peri UP (S355)


Yield Strength () = 355 Mpa ≈ 3,620 kg/cm2 (standard)
Tensile Strenght (τ) = 510 Mpa ≈ 5,200 kg/cm2 (standard)
Allowable Stress
Yeildd Stress () = 3,620 kg/cm2 ; Safety Factor = 1.67 (SNI 1729-2020)
Allowable Stress (  ) =  / 1.67
= 3,620 / 1.67
= 2,168 kg/cm2
Load Used :
Wind Load = 78.5 kg/m2 x 2.5 m = 196.25 kg/m
Live Load = 250 kg/m2 x 2.5 m = 625 kg/m
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 5 of 6
Area : Date : Rev :
Peri UP H: 6.3 m 28 July 2023 -

Result base on STAAD.Pro v8i :

1. Load and support modeling on staad.pro

Live Load Wind Load


Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 6 of 6
Area : Date : Rev :
Peri UP H: 6.3 m 28 July 2023 -

2. Ratio of material & Support Reaction

Support Reaction Ratio Material

3. Result of Structural analysis on combined load


ACTUAL ALLOWABLE
MATERIAL DESIGN PROPERTY RATIO RATIO STATUS
PERI UP UVR ROUND Ø48.3 X 3.2 0.728 1 OK
LEDGER UH TUBE 60X30X2 0.593 1 OK
PERI UP UBL ROUND Ø42.4 X 2.6 0.126 1 OK

Approved By : Check By : Made By :

Signature :
Name : ALF
Date : 28 July 2023