Professional Documents
Culture Documents
2023-07-28 Statik Peri Up H 6.3 M HSB
2023-07-28 Statik Peri Up H 6.3 M HSB
I. TECHNICAL DATA
b 0.2 cm
Ax 3.79 cm2
Ix 16.8 cm4
Wx 5.6 cm3
Sx 3.73 cm3
Δ max L/360
E 2,100,000 kg/cm2
σ allowable 2,168 kg/cm2
τ allowable 3,113 kg/cm2
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 3 of 6
Area : Date : Rev :
Peri UP H: 6.3 m 28 July 2023 -
III. LOAD
Dead Load
Dead Load used is Sefweight material. Selfweight material is weight materials used for formwork (automatically
calculated by Staad Pro)
Live Load
Live load consisting man power load and activity occurred at the casting. Live load used is 250 kg/m2.
Wind Load
Wind load is horizontal load for shoring. Wind load used is 78.5 kg/m2.
Material Spesification
a. For material Peri UP used Steel S355 with yield strength 3,620 kg/cm2 and tensile strength 5,200 kg/cm2
Load Combination
a. Load combination include Dead Load and Live Load with safety factor 1.67 (for allowable yield and tensile
strength).Method used in analysis is Allowable Stress Design (ASD) Method (SNI 1729-2020)
b. Load Combination = 1 DL + 1 LL + 1 WL
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 4 of 6
Area : Date : Rev :
Peri UP H: 6.3 m 28 July 2023 -
Signature :
Name : ALF
Date : 28 July 2023