You are on page 1of 2

C0307C - Tower Scaffolding for Overhead Crane

Project : C0307C
Works Item : Tower Scaffolding for Overhead Crane
Date : 28th August 2023

Tower Scaffolding for OHC Section Properties


Dimension Value Steel Pipe OD48.6 x 3.2WT
Length 2m Fy 240 MPa
Width 2m
Height 14 m

LOADS AND LOADING COMBINATIONS


LOADS
1. Dead load (DL) Structure of scaffolding using JIS pipe with diameter 48.6 mm and 3.2 mm thick.
Selfweight will be calculated automatically by STAAD Pro software.
2. Live load (LL) Floor live load for scaffolding structure is 2.5 kN/m^2.
3. Wind load (W) Wind loads for scaffolding structure assigned as intensity 0.7 kN/m^2 and
will be calculated automatically by STAAD Pro software.
4. Earthquake load (E) Earthquake loads not considered for temporary tower scaffolding structures
LOAD COMBINATIONS
· LOAD COMB 1 1.4DL
· LOAD COMB 2 1.2DL+1.6LL
· LOAD COMB 3 1.2DL+1.6LL+0.5WX
· LOAD COMB 4 1.2DL+1.6LL+0.5WZ

Dead Load (Selfweight) Live Load Wind Load Structure Analysis

Maximum utilization ratio =


0.484 < 1
Thus, OK.
CONCLUSION

Design of Scaffolding Structure

Isometric View Front View Side View Top View

Specifications :

Steel Pipe OD48.6 x 3.2WT


Fy 240 MPa
Length 2m
Width 2m
Height 14 m
Vertical Stair 75 °

Prepared Checked
RAF CAN