You are on page 1of 6
Ottice ofthe President ofthe Philippines PRESIDENTIAL COMMUNICATIONS OFFICE Manta 15 August 2023, REGIONAL DIRECTOR ERNESTO S, GREGORIO, JR. Department of Public Works and Highways — Regional Office Vil South Road Properties, Cebu City Re Visayas Media Hub’s (VMH) Satelite Tower Specification and Load Details Dear Regional Director Gregorio, Jr. ‘As requested, | am writing on behalf of the Presidential Communications Office (PCO) to formally submit the Satelite Tower Specification and Load Details for the VM, Uihich includes ‘he satelite tower and foundation, design loads, wind lozd, seismic load, antenna load, and satelite tower design and specifications, attached as Annex "A" hereof, for your review and consideration. ‘May we note that our personnel previously sent the same attachment to Engineer ame Roxette G. Carpio on 02 June 2023 and to you personally on 27 July 2023 when they went to Cebu to monitor and conduct an actual site inspection on the VIAH project. In view of the foregoing, we look forward to your consideration and appropriate action, in accordance with existing guidelines and applicable laws, rules, and reguations and without entaling additional cost to the PCO. Thank you. Very truly yours, CHERBETT KAREN L/MARALIT Underseéretary for Operations, Administration, and Finance 7h Por Ta Fiat Buin, UN Avene, eit Manila Cy, 100, Pirin A “ANNEX "A VISAYAS MEDIA HUB TOWER 3.4. TOWER AND FOUNDATION ‘The design criterion shall be applied to the structural analysis of proposed Tower and ‘supporting foundation including its sub-structures. 30 feet Self Supportirg Tower & Foundation with provisions for Microwave link STL and ICT communications. ‘The DesignerBullder shall design the tower with rest platforms and one (1) working platforms and vertical man-ladder in the given material specifications: 1. Landings- Heavy Duty Expanded metal 2. Vertical Man-tedder- round steel guard 3. Tower: Structural Steel (Tubular Pipe) in accordance to ASTM 36 or approved equivalent ho!-dipped galvanized) 4, Tower Painting: High Buld Self Priming Epoxy, Polyurethane Top-coat Design Loads “The minimum design loads forthe structure and supporting foundation shall be the weight of the structure incliding all appurtenances and attachment, lateral forces effects, differential movements, and restrained dimensional changes. Design loads and forces: are those resulting from dead loads, lve loads and lateral loads acting in the most cxitcal ‘combinations, using the appropriate load. 3.1.2. Wind Load ‘The structure and every portion thereof shall be designed and constructed to resist the wind effecis determined in accordance to the requirements NSCP 7th Edition, 2016, Factors recommended by the governing codes. The basic load types and thelr corresponding magntude are as follows: Please adhere to the Wind Pressure: updated government roquirement. Wind Veloaty: 290 Kph basic wind ‘speed Exposure a of Tinportance Factor: 115 | Gust Effect Factor: par NSCP 2015, 7th edition Force Coeff, Per tower pe! per NSCP 2015, 7th edition Solsmic Load The basie design seismic load for the siructure and portion thereof per NSCP shall design based on the provision of the National Structural Code of 2018, 7h Philippines 2015, 7th Edition. Seismic Force: lection Importance Factor: 750, [Seismic Zone: 4 ‘Seismic Source Fadlor por NSCP 2015, 7th edition Near Source Factor: per NSCP 2015, 7th edition 3.44 Antenna Load Microwave STL CommsiCT equipment (Equipment (Quantity [Weightect [rota Weght Microwave STL TransmiltedReceiver |2 set____[75 ka 1150 kg ICT Communications Equipment _|2 set [40 kg kg Cable 4set [Ska 0 kg 1250 Kg Please see the sample tower design attached. S Tove Base veTALS ‘PEDESTRIAN LADDER Cusceuows oeras ——9 oe PEDEST, WOUNT ETAL 8 af | CABLE LADOER HHH Tone Base eTALS PEDESTRIAN LADDER Quiscruatcous oxrang ee Ins ATOR SUPPORT OETAL ESTAL uN CETAL

You might also like