You are on page 1of 2

VALIANT

COMMUNICATIONS
VCL-2156, NTP SERVER

Product Overview
The VCL-2156 NTP SERVER is designed to provide NTP and ITU-T G.811 Primary Reference Clock that is locked to a GPS / GNSS reference to provide time
synchronization to private networks such as Railways and Metro (ticketing and platform) networks, Airports and Air-Traffic Control facilities, Electric
Sub-Stations, Power Distribution and Transmission companies, Oil and Gas Utilities, ISPs and Cable TV networks as well as to Campus networks that are
required to maintain a complete isolation from public networks for security reasons. It may be also used by 2G, 3G and LTE service providers which
provide a time of day reference to their customers over their wireless networks.
VCL-2156 locks to a GPS / GNSS reference to provide an NTP time reference on up to 4+1, 10/100BaseT Ethernet Ports which can be segregated to serve
separate classes of assets in the network.

Front View Back View

The VCL-2156 is equipped with a highly Performance:


Features and Highlights:
accurate, low-noise OCXO to provide a high VCL-2156 is designed to be deployed in
! GPS time reference for SCADA stability, ITU-T G.812, Type II, III compliant concurrent IPv4 networks to provide NTP time
applications holdover clock with better than 12μs accuracy and frequency synchronization.
! High bandwidth NTP performance over a 24 hour (5 milliseconds per year) period
in the event of unavailability of the GPS / GNSS The VCL-2156 has 4+1, 10/100 BaseT Industrial
! Upto 5000 NTP requests per second Ethernet Ports that meet and comply with
signal, or GPS / GNSS antenna failure, or a
! Multiple NTP Ports - 4+1 x “Power Contact and Lightening Protection” as
temporary loss of reception in a totally
Independent 10/100 Mbit/s, RJ-45 isolated network without any external per Telcordia GR-1089-CORE and EN61000-4-5
Ethernet interfaces reference. Level 4 specifications making it suitable for the
! ITU-T G.811 / Stratum 1 compliant equipment to be installed in harsh industrial
VCL-2156 establishes a highly accurate phase- environments which include Electric Sub-
(PR) Primary Reference when locked
synchronized frequency and time base by Stations, Railway and Metro Networks.
to GPS synchronizing to the GPS / GNSS satellites’
! ITU-T G.812 compliant holdover atomic clocks to distribute synchronized time VCL-2156 is powered by a high performance
! Synchronization of NTP and SNTP over packet based networks including microprocessor and a highly precise GPS / GNSS
clients Ethernet, Carrier Ethernet, IP and IP/MPLS receiver that provides a better than
! Leap Second correction Support Networks. 30 nanosecond accuracy to assure high
! MD5 authentication for NTP clients bandwidth NTP Performance of better than
The VCL-2156 provides a wide range of GPS /
5000 NTP requests per second.
! Supports 10000 NTP clients GNSS referenced frequency and time sources
! 1 x IRIG-B Un-Modulated (BNC) that include 2.048MHz, 10MHz, 1PPS Monitoring and Management:
! 1 x IRIG-B Modulated (RJ45) frequency as well as an NMEA and NTPv4 time
The configuration of the system can be managed
! Meets and comply with Power reference. Features such as maintaining a
by Graphical User Management Interface.
Contact and Lightening Protection as distinctly separate IP address for system
Alternatively, a text based and menu driven
management and control, password based
per Telcordia GR-1089-CORE and setup utility can be started from the shell
access, SSH as well as MD5 authentication
EN61000-4-5 Level 3 specifications. prompt after logging into the unit via Telnet or
ensures operational reliability and security.
! Alert notifications via SNMP Traps Additional features include remote login and
SSH. An optional Graphical User Network
! Concurrent IPv6 and IPv4 operation Management Interface (NMS) allows multiple
remote firmware upgrade (file transfer)
systems installed on a networks to be monitored
! Supported networking protocols: capabilities. VCL-2156 includes complete
and configured from a single or multiple
IPv4, IPv6, SSH, TELNET, FTP, SYSLOG SNMP monitoring as well as support for
management locations.
and SNMPv2 enterprise directory services for user
! Secure network management: enable authentication, internal and external logging
Standards & Compliance:
or disable options and monitoring of alarm and error messages
through Syslog ensures a high level of system ! IEC - EMC – Certified to EN 55022: 2005 /
! Double Oven Quartz Oscillators
manageability. Other features include DHCP CISPR 22, EN 55024:2005, IEC 61000-4-2
(OCXO) hold-over for installation convenience and support ! CE – 2001/95/EC, 2006/95/EC, EN60950-1,
! Stratum 1 when synchronized to concurrent IPv4/IPv6 support for future EN61000-6-2, EN61000-6-4
GPS/GNSS, or Stratum 2 hold-over network up gradation. ! FCC – FCC Part 15 B Class A: Conducted
! DC, or AC, or 1+1 Redundant AC+DC Emission test on Power Line
Power Supply options. ! FCC Part 15 B Class A: Radiated Emission >1
GHz FCC, 6 GHz, on Power Line

www.valiantcom.com 1
Valiant Communications Limited VCL-2156, NTP Server

Technical Specifications: Frequency and Time Outputs: Environmental (Equipment):


GPS/GNSS Receiver Specifications: ! 1 x 2.048 MHz, 75 Ohms, phase-locked to Operational: -10C to +65C (Typical: +25C)
GPS (BNC). ITU-T G.811 compliant. Cold start 0C to +50C
! 50 Channel GPS Receiver
! 1 x 10 MHz, 50 Ohms, phase-locked to Storage -20C to +70C
! 72 Channel GNSS Receiver
GPS (BNC). ITU-T G.811 compliant. Humidity 95% non-condensing
! GPS L1 frequency, C/A Code Receiver
! 1 x 1 PPS, phase-locked to UTC (BNC) Cooling Convention Cooled.
! Tracks up to 12 satellites simultaneously
! 1 x ToD (Time-Of-Day) output compliant No cooling fans are required.
! Synchronizing Time:
to NMEA 0183 (Db9)
– Acquisition time - Hot Start: 1 sec.
! 1 x IRIG-B Un-Modulated (BNC) Mechanical Specifications:
– Acquisition time - Warm Start: 28 sec.
! 1 x IRIG-B Modulated (Rj45)
– Acquisition time - Cold Start: 28 sec. Height 44 mm
! 1 x 1 PPM
! GPS Signal Width 480 mm (DIN 19-inch)
– Tracking and Navigation: -162 dBm Depth 225 mm
– Reacquisition -160 dBm Network Time Protocol: Weight 2.3 Kg
– Cold Start -148 dBm Rack Mount Options 19”, 21”, 23” Rack
! NTP v2, (RFC 1119), NTP v3 (RFC 1305),
! Antenna Connector: TNC mounting options
NTP v4, (RFC 5905), SNTP v3 (RFC 1769),
! Accuracy Of Time-Pulse Signal referenced
SNTP v4 (RFP 2030), MD5 Authentication
to GPS: +/-30ns (raw) Power Supply Options:
! Internet Protocol: IP v4
! Accuracy Of Time-Pulse Signal referenced
! Time Protocol: TIME (RFC 868) ! Dual Redundant
to GNSS: +/-20ns (raw)
! Daytime Protocol: DAYTIME (RFC 867) ! 1+1 AC power (100 to 240V AC, 50/60 Hz)
! Accuracy Of Time-Pulse Signal referenced
! 1+1 DC 24V
to GPS/GNSS: +/-15ns (compensated)
Display : ! 1+1 DC -48V
(Note: with all satellites in view at -130db)
! 1+1 DC 110~220V
! LCD-display with back-light
! AC or DC
Holdover (G.812) Synchronization:
Local / Remote Management and Power Consumption:
! OCXO (Double Oven-Controlled Crystal Monitoring Ports:
Oscillator) ! < 15W at ambient (steady state 24°C)
! RS-232C
Accuracy
! USB
! 0.5ppb per day Antenna Specifications:
! 10/100BaseT Ethernet RJ45
! 50ppb per year !
! 2 x External Alarm Relay Contacts. Antenna Type: Active
! Polarization: Right hand circular
Synchronization Inputs: ! Frequency Band: 1575.42 MHz + 10 MHz
Local / Remote Communication Options:
! 1 x GPS (TNC) ! Amplifier Gain: 40dB + 4dB
! Telnet / SSH ! VSWR: <2.0 Max, 1.0 Typical
(option to disable clear text ! Operating temperature: -40C to +85C
NTP Outputs:
communication to comply with NERC ! Reverse Polarity Protection
! 4 x 10/100Mbps NTP Interfaces security requirements) ! Out of Band Rejection: > -60dB @ +50MHz
! 1 x 10/100Mbps user configurable NTP ! CLI Control Interface (HyperTerminal or off center (1575.42 MHz) frequency
interface VT100) ! Lightening Protection: According to
! SNMP V2 Traps (MIB File provided). EN61000-4-5 Level 4.
Configuration and Monitoring Software: ! LMR400 (or equivalent) Cable Length - 30,
! Telnet, SSH, CLI Security and Protection: 50, 60 and 90 meters
! NMS - GUI (Graphical User Interface) - Runs MTBF:
! Password Protection with password
on any PC operating on Windows 7, ! Per MIL-HDBK-217F: ≥ 37 years @ 24C
strength monitor
Windows 8 or Windows 10 OS. !
! SSH Per Telcordia SSR 332, Issue 1: ≥ 42 years
@ 24C
Ordering Information:
Part Number Description Power
VCL-2156-NTP-yy NTP Server yy: AC or ACR or DC or DCR or ACDC (1+0, 1+1, AC+DC)

Technical specifications are subjects to changes without notice.

Revision 3.4 - November 20, 2017

U.K. U.S.A. INDIA

Valiant Communications (UK) Ltd Valcomm Technologies Inc. Valiant Communications Limited
1, Acton Hill Mews, 4000 Ponce de Leon, Suite 470 71/1, Shivaji Marg,
310-328 Uxbridge Road, Coral Gables, FL 33146 New Delhi - 110015,
London W3 9QN, United Kingdom U.S.A. India

www.valiantcom.com 2

You might also like