Professional Documents
Culture Documents
Common Error Codes and Parts
Common Error Codes and Parts
Door ajar - the door has been impacted return the door to the full open
F060 position and hold the reset button to clear
Edge trip – the door came down on something 3 times and will need to be
F361 reset by holding down the reset button
Edge open at mobile unit channel 1 - make sure that the resistor on the
F831 reversing edge air switch has a tight connection
Wireless communication error - check the mobile unit battery while under
F856 load it should read 3.61vdc or greater
F969 Clock chip – the clock needs to be reset; set parameter C01 though C04
Photo eye Check that all 4 photo eyes are functioning properly and are lined up with
222 or 232 each other
This list is of most common error codes; if not indicated above please contact Rytec Technical Support.
Common Parts
Turbo-Seal® Insulated®/ Preda-Door® NXT®
Sure-Seal™ Powerhouse®
Wireless Battery R00111193 R00111193
Mobile Unit R1180001-0C R1180001-0B
Encoder R00142058 R00142058
Photo eyes (Receiver) 1160145-0 (Receiver) 00141088 (Receiver)
(Transmitter) 1160153-0 (Transmitter) 00141087 (Transmitter)
Controller R00142000 R00142000
Counterweight Strap R1170057-0
End Tabs R1170827-0
Door models and configurations may vary along with part numbers. Please provide door serial number
when contacting Rytec.
HIGH-PERFORMANCE DOOR
DOOR MODEL:
Quick Reference Guide
Turbo-Slide®
Photo eye Check that all 4 photo eyes are functioning properly and are lined up with
222 or 232 each other
This list is of most common error codes; if not indicated above please contact Rytec Technical Support.
Common Parts
Turbo-Slide®
Bulb Seals Configured on door size
Panel Seals Configured on door size
Trolley Rollers P1091160-0C
Stay Rollers P1091170-0
Encoder R00141134
Controller R00142000
Chain Release Cable P1091135-0
Door models and configurations may vary along with part numbers. Please provide door serial number