Tracer™ CH530

Chiller Controller

for EarthWise™ CenTraVac™


Revolutionary control of the
chiller, chilled-water system,
or your entire building

It makes sense that the leader in chiller If you are replacing a chiller or adding
design also offers the most advanced one to any centrally controlled plant, the
capabilities for chiller plant management. Tracer CH530 chiller controller offers a
Since 1985, we’ve been electronically wide range of interface options. Its ability
controlling our chillers, chilled water to communicate with other systems
systems, and entire buildings, with a using industry-standard control signals
proven history of integrating chillers and allows you to upgrade the control of your
controls into total systems that perform chiller plant regardless of your current
better. control system. A Tracer Summit system
Part of a larger system can support both of the leading
We’re not satisfied with merely providing interoperable communications
the world’s most efficient centrifugal standards—BACnet™ and LonTalk®.
chiller. The Tracer™ CH530 chiller When updating your chiller, it may also
controller is designed to serve as an be the ideal time to introduce the benefits
important component in a comfort of Trane controls across more of your
control system. Although Tracer CH530 facility. Trane offers the expertise and
can communicate with many building solutions you need, for both the short
automation systems, the Tracer Summit™ and long term.
building automation system allows you
to fully leverage the chiller’s Adaptive
Control™ capabilities, so the overall
system stays at its peak efficiency.
In addition to system-level equipment
coordination, Tracer Summit also
provides crucial reports on energy
efficiency, operating status, and
refrigerant management.

© 2001 American Standard Inc. All rights reserved CTV-SLB011-EN


Unprecedented accuracy and fast
reactions keep your chiller on line

Adaptive Control Intelligently satisfies multiple


objectives
Tracer CH530 constantly receives
Variable water flow through
the evaporator
Chilled-water systems that vary water
Chiller reliability is all about producing information about key data parameters— flow through chiller evaporators have
chilled water and keeping it flowing, even temperatures and current are two caught the attention of engineers,
when facing conditions that ordinarily examples. Every five seconds, a multiple- contractors, building owners, and
would shut down the chiller—conditions objective algorithm compares each operators. Varying the water flow reduces
that often happen when you need parameter to its programmed limit. the energy consumed by pumps, while
cooling the most. Whenever the controller senses a requiring no extra energy for the chiller.
Faster, more accurate response keeps situation that might trigger a protective This strategy can be a significant source
the chiller online whenever possible shutdown, it focuses on bringing the of energy savings, depending on the
Tracer™ CH530 collects three rounds of critical parameter back into control. application.
data per second, 55 times the data When the parameter is no longer critical With its faster and more intelligent
collection speed of its predecessor. It or if another parameter becomes more response to changing conditions, Tracer
does this by using smart devices. Each critical, the controller switches its CH530 reliably accommodates variable
device (e.g., sensor) has its own objective—back to controlling the chilled evaporator water flow and its effect on
microprocessor that simultaneously water temperature, or to the more critical the chilled-water temperature. These
converts and accurately calibrates its parameter. improvements keep chilled water flowing
own readings from analog to digital. One example of how the controller at a temperature closer to its setpoint.
Because all devices are communicating averts a shutdown occurs during an Rides out power disturbances
digitally with the main processor, there inverted start. Improved power measurement and
is no need for the main processor to An inverted start occurs when the protection algorithms allow the unit to
convert each analog signal one at a time. refrigerant is “stuck” in the condenser, accommodate more power anomalies
This distributed logic allows the main which is temporarily at a lower than ever. If the chiller must shut down,
processor to focus on responding to temperature than the evaporator. faster restarts get the machine up and
changing conditions—in the load, the By tightly controlling down to the low- running as soon as possible.
machine, its ancillary equipment, or its refrigerant-temperature cutout, the EarthWise™ Purge
power supply. controller reduces the chilled-water Trane has also revolutionized its
temperature while simultaneously controller-integrated purge, which
coaxing the refrigerant back into features an automatic regeneration
the evaporator. system for high-efficiency, maintenance-
free refrigerant containment. Air and
Inverted Water Temperature Start noncondensables are pumped out
Low Refrigerant Temperature Limit
twice as fast, and its lower temperature
Controlling to Controlling to Controlling to refrigeration system enhances the base
100 Chilled-Water Refrigerant Chilled-Water purge efficiency.
Leaving Temperature Temperature Leaving Temperature Unit-mounted medium–
90 Chilled Water voltage starter
Entering Temperature Take advantage of Tracer CH530’s new
Chilled Water starter module and save space in your
80 Leaving Temperature equipment room. There is no need for a
remote or floor-mounted starter with our
70 new, exclusive, unit-mounted, medium-
voltage starter from Cutler-Hammer.
Temperature [ F]

60 Evaporator Adaptive Frequency™ motor drive


Refrigerant Tracer CH530 complementsTrane’s
Temperature Adaptive Frequency motor drive (AFD)
50 system for chillers better than ever before.
Chilled Water Setpoint Brand new control algorithms allow safe,
40 more efficient inlet vane and motor speed
Low Refrigerant Temperature Limit control operation to maximize part-load
performance.The AFD goes to its final
30
speed-control point in a fraction of the
Low Refrigerant Temperature Cut-out time it used to take, which allows you to
Time
20 limit the starting current if necessary.

CTV-SLB011-EN
Information tailored to
operators, service
technicians, and owners

Touch sensitive screen provides information


and navigation at the same time

Change setpoints and settings with touch


screen commands

Displays chiller status and operating points.


Touch for more information

If diagnostic exists, an alarm indicator will


appear. Press for detail.

On and off buttons

Extensive diagnostics customized to the


chiller type installed—centrifugal, helical
rotary, or absorption

TechView™ chiller service tool—


When operating a chiller, there is A portable control panel interface
specific information you need on a for the service technician or
day-to-day basis—operating mode, advanced operator Similarly, TechView accommodates
setpoints, limits, diagnostic When you need more detailed a primary and a secondary language
information, and reports. information about a Trane chiller, from the same list of available
When servicing a chiller, you need connect your laptop computer to languages.
different information and a lot more DynaView’s plug-in port. TechView’s A new level of serviceability
of it—historic and active diagnostics, user interface provides access to that Using the innovative TechView chiller
configuration settings, and particular machine’s configuration service tool, a technician can interact
customizable control algorithms, settings, customizable limits, status, with an individual device or a group
as well as operation settings. and up to 60 active or historic of devices for advanced
diagnostics. Any computer that troubleshooting. LEDs and their
By providing two different tools— meets the system requirements may
one for daily operation and one for respective TechView indicators
download up-to-the-minute visually confirm the viability
periodic service—everyone has easy DynaView and TechView software
access to pertinent and appropriate of each device.
from The Trane Company’s Web site,
information. www.trane.com. Without changing Advanced interoperability
DynaView™ human interface— any hardware, we give you access to Tracer CH530 can provide generic
A streamlined display for day-to- the latest and greatest version of BAS I/O points to any other plant
day operation Tracer CH530! controller and/or communicate with
Day-to-day operational information the Tracer Summit™ chiller plant
User-defined language support manager using COMM4. From the
is presented at the panel. Up to DynaView is capable of displaying
seven lines of data (I-P or SI units) chiller plant manager, chiller points
English text or one of the two can be exchanged using BACnet.
are simultaneously displayed on alternate languages that are stored
the one fourth VGA touch-sensitive in DynaView at one time. Switching
screen. Logically organized groups languages is easily accomplished
of information—chiller modes of from a settings menu.
operation, active diagnostics,
settings, and reports—put
information conveniently at your
fingertips.

CTV-SLB011-EN
Introducing TracerCH530 for
the EarthWise™ CenTraVac™

Control functions Protections Monitored points


• Evaporator leaving-water • Loss of evaporator or • Operating mode
temperature condenser water flow • Setpoint value
• Chilled-water reset based on • High condenser pressure • Setpoint source
return water temperature • Evaporator water temperature • Evaporator and condenser
• Ability to control with variable • Low refrigerant temperature system water temperature
water flow • Starter contactor failure • Refrigerant/solution evaporator
• Evaporator refrigerant • Current overload and condenser temperature
temperature limit • Phase unbalance, phase loss, • Starts and run-hour meter
• Condenser pressure limit (derived) phase reversal • Phase currents, voltages, kW,
• Soft-loading • Undervoltage/overvoltage power factor
• Smart auto-restart Momentary power loss/ • Current-limit setpoint
• Current-limit mode distribution fault • Oil temperature and pressure
• Limit relays • High motor-winding temperature • Purge suction temperature
• Pump start/stop • Smart short-cycling protection • Purge elapsed time
–cooling water • Current limit • Pumpout activity and time to
–chilled water • Surge detection and protection next purge
• Oil temperature …and more
Optional: • Oil pressure
• Heat recovery • Continuous and/or excessive Optional:
• Free cooling purge detection • Evaporator and condenser water
• Chilled-water reset based on • Excessive air leakage flow and capacity (tons or kW)
ambient temperature • Auxiliary and heat recovery
• Adaptive Frequency™ drive Optional: condenser temperatures
• Hot-gas bypass • High compressor discharge • Discharge compressor temperature
• Ice-making control temperature • Condenser pressure
• Hot-water control • Bearing temperatures
• Base load/24 hour operation
• Remote setpoint control
• Remote enable/disable
• Condenser pressure limit
(transducer)
• Generic BAS I/O

CTV-SLB011-EN
Literature Order Number CTV-SLB011-EN
File Number August 2001
Supersedes New

The Trane Company Stocking Location La Crosse


An American Standard Company
www.trane.com
For more information contact
your local district office or Since The Trane Company has a policy of continuous product and product data improvement, it reserves the
e-mail us at comfort@trane.com right to change design and specifications without notice.