3D TRASAR® Boiler Technology Detects,

Determines and Delivers the Next


Dimension of Boiler Water Management

3D TRASAR automation and control determines and adjusts the


is now available for boiler water correct program dosage. Nalco
treatment. 3D TRASAR boiler continues to improve 3D TRASAR
automation continues to build on technology, making it the industry
the Nalco 3D TRASAR platform, standard for monitoring and
advancing the premiere technology control that delivers measurable
in control capabilities. results.
The 3D TRASAR boiler system The NCSM minimizes preboiler
uses the Nalco patented fluores- corrosion by measuring and
cence technology program for boiler reacting to the net oxidation/
scale control, and introduces a reduction potential of the bulk
unique, patented Nalco Corrosion feedwater, at the actual boiler
Stress Monitor™ (NCSM) for operating temperatures and
preboiler corrosion control. pressures. The NCSM detects
changes in oxidation/reduction
Boiler scale control is achieved
stress, determines the corrective
with an updated version of the tried-
action and responds in real-time
and-true 3D TRASAR controller
by changing oxygen scavenger or
coupled with the most advanced
metal passivator feed to protect
boiler internal treatment programs to
the system. It is now possible to
protect your boiler from scale and
detect and react to the conditions
deposits. The 3D TRASAR program
inside the preboiler system under
detects system variations, then

Table 1 – 3D TRASAR boiler technology can be customized and upgraded to ensure your
system has the amount of desired control when and where you want it.

3D TRASAR Boiler Technology


Model Model Model
Feature Descriptions BLx54xx BLx55xx BLx53xx
3D TRASAR Controller & Configurator Software S S S
Communication for Remote Monitoring & Alarming C C C
Web Reporting & Data Management C C C
3D TRASAR Fluorometer for Scale Control S S U
Nalco Corrosion Stress Monitor (NCSM)
for Preboiler Corrosion Control U* S, U* S, U*
Maximum pressure 1500 psi (103 bar) S S
Maximum pressure 2800 psi (193 bar) S
Conductivity – Based Blowdown Control U** U** U**
Feedwater pH & Conductivity Monitoring U*** U*** U***
S = Standard feature C = Customized U = Upgrade available *can have 2 total
**up to 4 boilers ***High purity and low purity water options
Note: See global part numbering system on page 9.

1 Bulletin B-950
High pressure sample point (preferred installation) Low pressure sample point

actual operating temperatures and 3D TRASAR boiler technology can The controller, equipped with the
pressures, allowing 3D TRASAR also help keep the boiler water optional relay box, can operate up
technology to deliver superior boiler conductivity in the correct range by to four blowdown control valves.
system performance. automatically blowing down water A conductivity probe assembly,
at high solids levels so it can be motorized valve and flow control
3D TRASAR boiler technology can
replaced with low-conductivity valve are needed for each boiler to
be customized and upgraded to
make-up water. The controller can be controlled.
ensure your system has the amount
be set up for either intermittent or
of desired control when you want it. 3D TRASAR boiler technology is
continuous sampling. A variety of
3D TRASAR boiler automation just one more example of how
control, sampling and measurement
continuously measures key param- Nalco innovation protects your
options provides the flexibility to
eters, detects system variability and boiler systems, saves water and
optimize system operation.
upsets, determines and executes energy and increases efficiency.
appropriate corrective action and 3D TRASAR technology detects,
delivers measurable results. It has determines and delivers the
web accessibility and easy reporting next dimension in boiler water
capabilities in one, easy to install management.
package.

2
Maximum 10’ distance – boiler to
electrode with minimal unions, valves
and elbows that can cause flashing.
Motorized
Skimmer (surface) blowdown line
ball valve Main flow
Mount away from heat
4-6” below minimum water level control valve
of boiler and below the
to ensure sample does not
level of the boiler Mount within 12”-18” of
contain steam
close to the floor motorized ball valve to
Main avoid water hammer
steam 1” gate valve full-port for isolation

Boiler 1” piping 12” to 18”


electrode to
• Electrode should NOT

}
Steam
be mounted at the highest flow control Low voltage Sensor and
drum
point in th piping run valve electrode signal control valve
where steam can collect wired to
• Bushing up piping at or 120 VAC 3D TRASAR®
before electrode will valve control Controller
cause flashing
Conductivity sensor
1”- 3/4” reducer

1” gate valve 1” piping 3/4” Pipe run


full – port or 1/2” above
piping Electrode 1/2”
for isolation sensor
leakage piping
to ensure
Minimum 2’ horizontal pipe run safety
pipe remains
to reduce turbulence in sample line drain line
full at
sensor cross
3/4” Electrode cross
To drain
1/2” flushing valve
(to clean electrodes
and chamber) High
conductivity
blowdown to
drain
Timed blowdown
Timed blowdown (Sampling) is recommended for smaller boilers Note
with blowdown requirements of less than 5,000 lb/hr. The boiler Steam in the boiler blowdown line will result in erratic
water is periodically sampled for conductivity. This is done in order conductivity readings, drifting and poor control and greatly
to maintain the boiler water level and not ‘over blow’ the boiler. reduce the life of sensors and valves.

Intermittent boiler blowdown sampling

Maximum 10’ distance – boiler to


electrode with minimal unions, valves
and elbows that can cause flashing.
Motorized
Skimmer (surface) blowdown line
ball valve Main flow
Mount away from heat
4-6” below minimum water level control valve
of boiler and below the
to ensure sample does not
level of the boiler Mount within 12”-18” of
contain steam
close to the floor motorized ball valve to
avoid water hammer
1” gate valve full-port for isolation
12” to 18”
Main electrode to
steam flow control
1” piping valve
• Electrode should NOT
Boiler

}
be mounted at the highest Low voltage Sensor and
Steam point in th piping run electrode signal control valve
drum where steam can collect wired to
®
• Bushing up piping at or 120 VAC 3D TRASAR
before electrode will valve control Controller
Feed cause flashing
3/4”
or 1/2”
1” piping piping

High conductivity
Conductivity blowdown to drain
1” gate valve
sensor Continuous
full-port
for isolation flow control
1”- 3/4” valve
Mud reducer
drum 1” piping

Minimum 2’ horizontal
pipe run to reduce Pipe run
turbulence in sample line above
Electrode 1/2”
sensor
leakage piping
3/4” Electrode cross to ensure
safety
pipe remains
drain line
1/2” flushing valve full at
(to clean electrodes sensor cross
and chamber)
To drain Continuous
blowdown
to drain

Continuous blowdown Note: Steam in the boiler blowdown line


Continuous blowdown (Sampling) is recommended for boilers with blowdown requirements of over will result in erratic conductivity readings,
5,000 lb/hr. This system allows for continuous monitoring and control of boiler water conductivity. drifting, poor control and greatly reduce
the life of sensors and valves.

Continuous boiler blowdown sampling

3
Feed and Control Methods Blowdown Control
Chemical Feed – Scale Inhibitor • Based on conductivity or TRASAR measurements
• On/Off or PID based on TRASAR signal • Continuous or intermittent sampling
• Slaved to steam flow • ON/OFF, PID or Time-base
• Timer proportional control
• Manual • Trap sample capability
• High/low demand sampling
Chemical Feed – Scavenger/Passivator
schedules
• On/Off or PID based on NCSM signal
• Slaved to steam flow or TRASAR signal
• Timer
Monitoring Functions
Additional Monitored Variables
• Manual
• Cell Fouling
Chemical Feed – Amines • Turbidity
• Slaved to steam flow • Temperature
• Slaved to scale or corrosion • Output Status
inhibitor • Pulse counter with water meter
• Timer
Additional Calculated Variables
• Manual
• Pump Duty
• Product Usage

Specifications
The 3D TRASAR boiler systems consist of a number of modules. The modules are factory-assembled
on either wall-mountable back plate or on a free-standing frame. This modular design provides a broad
range of monitoring and control capabilities.

Sample Limits for 3D TRASAR System Modules


High Pressure Sample Low Pressure Sample
NCSM Conditioning System Conditioning System
Minimum Sample Pressure 20 psi (1.4 bar) 50 psi (3.4 bar) 20 psi (1.4 bar)
Maximum Sample Pressure 2800 psi (193 bar) 1500 psi (103 bar) 50 psi (3.4 bar)
Maximum Sample Temperature 500ºF (260ºC) 500ºF (260ºC) 500ºF (260ºC)
Minimum Sample Flow 250 cc/min 250 cc/min 250 cc/min
Maximum Sample Flow 500 cc/min 1500 cc/min 1500 cc/min
Note: The system’s sample temperature, pressure and flow limits are defined by the lowest limit of any module included in the system.

4
NCSM Module: Electrode Cable: 4-conductor, shielded, 22 AWG min.
Maximum Sample Pressure: 2800 psi (193 bar) Electrode Leads: PVC coated, 48” (1.2 m)
Maximum Sample Temperature: 500°F (260°C) Range:
Sample Flow: 250-500 cc/min Low purity feedwater probe: 100-10,000 μS/cm
Inlet/Outlet Connection: 1/4” SS tubing High purity feedwater probe: 5-500 μS/cm
Wetted Materials: 316 SS, Teflon, Zirconia, Platinum,
PEEK
Sensor Protection: Blowdown Relay Box
Indoor Model: Lexan shield Electrical Power: 115 VAC, 60 Hz, 10 Amps
Enclosed Model: Vented SS enclosure (separate line required)
Mounting Holes: 7/16” diameter Power Cable: 15 ft (no receptacle plug)
Cable with signal booster: Enclosure: Nema 4X
Ambient Conditions: 40°F (4°C) to 140°F (60°C) Number of Relays: 4
Note: Allow at least 8-10 inches below the NCSM Relay Type: SPDT (single pole double throw),
sensor for servicing the reference electrode. 115 VAC, 60 Hz

Fluorometer Module: Analog Input Module


TRASAR Chemistry Measured: TRASAR #3 Electrical Power: 115 VAC, 60 Hz, 5 Amps
Lower Detection Limit: 0.05 ppb as TRASAR #3 (separate line required)
(0.2 ppm if Product Factor is 40) Power Cable: 6 ft (no receptacle plug)
Upper Measurement Limit: 150 ppb as TRASAR #3 Connection to controller: RS-485 (cable not supplied)
(600 ppm if Product Factor is 40) Number of Inputs: 8
Sample Temperature Limit: 40-120°F (4-50°C) Input Type: 4-20 mA, non-isolated (powered or unpowered)
Resolution: 16 bits
pH Probe (High Purity): 24 VDC Power Source: +24 VDC @ 500 mA
Maximum Pressure: 50 psi (3.4 bar) (maximum draw) regulated power source
Maximum Temperature: 167˚F (75˚C) Enclosure: Nema 4X
Electrode Mounting: 1” ( install in1” FNPT cross w/1”
tube to NPT adapter) Sample Conditioning System:
Electrode Cable: 2-wire, 4-ft (1.2 m) High Pressure Feedwater System
Applications: Samples with 5-500 μS conductivity Maximum Sample Pressure: 1500 psi (103 bar)
Minimum Sample Pressure: 50 psi (3.4 bar)
pH Probe (Low Purity): Maximum Sample Temperature: 500°F (260°C)
Maximum Pressure: 150 psi (10.3 bar) Sample Flow: 250-1500 cc/min
Maximum Temperature: 230˚F (110˚C)
Low Pressure Feedwater System
Electrode Mounting: 3/4” ( install in a 3/4” FNPT cross)
Sample Pressure: 7-50 psi (0.5-3.4 bar)
Electrode Cable: 2-wire, 6-ft (2 m)
Maximum Sample Temperature: 250°F (122°C)
Applications: Samples over 500 μS conductivity Sample Flow: 250-1500 cc/min
High Pressure Blowdown System
Conductivity Probe (Blowdown & Maximum Sample Pressure: 1500 psi (103 bar)
Condensate): Minimum Sample Pressure: 50 psi (3.4 bar)
Maximum Pressure: 250 psi (17.2 bar) Maximum Sample Temperature: 500°F (260°C)
Maximum Temperature: 392°F (200°C) Sample Flow: 250-1500 cc/min
Electrode Mounting: 3/4” MNPT, install in 3/4” Cooling-Depressurizing System
NPTF cross Maximum Pressure: 2800 psi (193 bar)
Electrode Cable: 4-conductor, shielded, 22 AWG min. Maximum Temperature: 500°F (260°C)
Electrode Leads: Teflon coated, 8” (0.2 m) Sample Flow: 250-500 cc/min
Temperature Compensation: Optional
Range: Note: Use only for cooling and depressurizing the
Blowdown probe: 100-10,000 μS/cm sample before discharging it directly to a suitable drain.
Condensate probe: 5-500 μS/cm DO NOT install upstream of instrumentation.
All Sample Conditioning Systems
Conductivity Probe (Feedwater) Inlet Connection: 1/4” SS tubing
Max. Pressure: 200 psi (13.8 bar) Outlet Connection: 1/4” MNPT
Max. Temperature: 158˚F (70˚C) Wetted Materials: 316 SS, Teflon, Acrylic, PVC,
Electrode Mounting: 3/4” MNPT, install in 3/4” FNPT tee Polyethylene, Nylon, Polypropylene, Viton

5
3D TRASAR Controller • Optional wireless gateway with monthly service
Electrical package.
90 to 240 VAC, 50/60 Hz, 15 Amps
Approvals
Inputs CE, UL (pending), CUL (pending)
• (4) Analog inputs, non-isolated, 4-20 mA or 0-10 V
(user-selectable), powered or non-powered Software
• 3D TRASAR Configurator for system configuration
• (1) Interlock input (contact closure) and data transfer
• (4) Digital inputs (contact closure or transistor) • Optional Vantage® 100 SPC software for comprehen-
discrete or low frequency water meter counts sive data management and analysis.
• (2) pH/NCSM user selectable, individually isolated
• (6) Contacting conductivity inputs (2 or 4 wire) System Dimensions
• (3) Temperature (RTD, PT1000) inputs (4 wire) Wall Mount Controller & Sensor Panel:
Dimensions: 12” D x 33” W x 42” H
• (2) Fluorometer inputs (Modbus)
(31 cm x 84 cm x 107 cm)
• Modbus RS-232 or RS-485 (choose one) RTU Material: PVC back panel
SCADA port Mounting Holes: 7/16” diameter

Sample Conditioning System:


Outputs
Dimensions: 8” D x 33” W x 22” H
• (5) control relay outputs rated 2.0 amps each
(21 cm x 84 cm x 56 cm)
(larger loads require external motor starters)
Material: PVC back panel
• (8) 4-20 mA outputs, powered, non-isolated,
Mounting Holes: 7/16” diameter
600 ohms
Frame Mounted System:
Alarms Dimensions: 29” D x 33” W x 66” H
• (1) Alarm output relay (rated 1.0 amp max) (74 cm x 84 cm x 168 cm)
Material: PVC back panel on SS frame
Enclosure
Nema 4X Note: The Sample Conditioning System must be field
mounted 1-1/2” (3.8 cm) below the Control and Sensor
Ambient temperature Panel for all Wall Mount installations.
40-120°F (4-50°C)
Relative Humidity
0-95% non-condensing Support
Please contact your local Nalco Sales Engineer if you
Display/Keypad have any questions. In North America, you can also
Numeric keypad plus specialty keys contact the Nalco Equipment Solutions Technical
Support Group at 1-800-323-8483.
Security
Password protected (user assignable)

Communications
3D TRASAR System Diagrams
• (2) Ethernet port for direct PC connection, network The following diagrams are representative of the
or wireless gateway systems in each model series. They have been selected
to illustrate the broad variety of possible configurations.
• USB memory stick (approved devices only)
The actual equipment included in each system is
• Built-in modem for direct remote connection or dependent on the specific model number.
access to 3D TRASAR Web via Internet
(requires ISP)

6
060-BLx55xxxx.88 Series

Part Number 060-BL5521BH.88 Part Number 060-BL5522BH.88

060-BLx54xxxx.88 Series

Part Number 060-BL5421BH.88 Part Number 060-BL5420BH.88

7
060-BLx53xxxx.88 Series

Part Number 060-BL5321.88 Part Number 060-BL5302.88

060-BLx52xxxx.88 Series 060-BDCx100.88 Series

Part Number 060-BDC100.88


Part Number 060-BL5223.88

8
3D TRASAR Boiler System Numbering Convention

Model Region
Series USA Canada Europe Latin America Asia-Pacific
110 VAC/60 Hz 110 VAC/60 Hz 220 VAC/50 Hz 110 VAC/60 Hz 220 VAC/50 Hz 220 VAC/50 Hz
BL52xxx 060-BL52xx.88 060-BL52xx.88 060-BLM52xx.88 060-BL52xx.88 060-BL52xx.88 060-BL52xx.88
BL53xxx 060-BL53xx.88 060-BLC53xx.88 060-BLM53xx.88 060-BLL53xx.88 060-BLLC53xx.88 060-BLPC53xx.88
BL54xxx 060-BL54xx.88 060-BLC54xx.88 060-BLM54xx.88 060-BLL54xx.88 060-BLLC54xx.88 060-BLPC54xx.88
BL55xxx 060-BL55xx.88 060-BLC55xx.88 060-BLM55xx.88 060-BLL55xx.88 060-BLLC55xx.88 060-BLPC55xx.88
Notes: BL52xxx models do not require a power supply.

3D TRASAR Technology for Pre-Boiler Control


Scale Control and Corrosion Stress Control
Corrosion Stress
Sample Conditioning System Mounting Feedwater pH & Conductivity
Monitor Blowdown
Controller Fluorometer
Lexan SS High Low Relay Box
None Wall Frame High Purity Low Purity None USA Part Number
Shield Enclosure Pressure Pressure
Y Y Y Y Y Y 060-BL5520.88
Y Y Y Y Y Y 060-BL55200L.88
Y Y Y Y Y Y 060-BL55200H.88
Y Y Y Y Y Y Y 060-BL5520B0.88
Y Y Y Y Y Y Y 060-BL5520BL.88
Y Y Y Y Y Y Y 060-BL5520BH.88
Y Y Y Y Y Y 060-BL5521.88
Y Y Y Y Y Y 060-BL55210L.88
Y Y Y Y Y Y 060-BL55210H.88
Y Y Y Y Y Y Y 060-BL5521B0.88
Y Y Y Y Y Y Y 060-BL5521BL.88
Y Y Y Y Y Y Y 060-BL5521BH.88
Y Y Y Y Y Y 060-BL5522.88
Y Y Y Y Y Y 060-BL55220L.88
Y Y Y Y Y Y 060-BL55220H.88
Y Y Y Y Y Y Y 060-BL5522B0.88
Y Y Y Y Y Y Y 060-BL5522BL.88
Y Y Y Y Y Y Y 060-BL5522BH.88
Y Y Y Y Y Y 060-BL5523.88
Y Y Y Y Y Y 060-BL55230L.88
Y Y Y Y Y Y 060-BL55230H.88
Y Y Y Y Y Y Y 060-BL5523B0.88
Y Y Y Y Y Y Y 060-BL5523BL.88
Y Y Y Y Y Y Y 060-BL5523BH.88
Y Y Y Y Y Y 060-BL5510.88
Y Y Y Y Y Y 060-BL55100L.88
Y Y Y Y Y Y 060-BL55100H.88
Y Y Y Y Y Y Y 060-BL5510B0.88
Y Y Y Y Y Y Y 060-BL5510BL.88
Y Y Y Y Y Y Y 060-BL5510BH.88
Y Y Y Y Y Y 060-BL5511.88
Y Y Y Y Y Y 060-BL55110L.88
Y Y Y Y Y Y 060-BL55110H.88
Y Y Y Y Y Y Y 060-BL5511B0.88
Y Y Y Y Y Y Y 060-BL5511BL.88
Y Y Y Y Y Y Y 060-BL5511BH.88
Y Y Y Y Y Y 060-BL5512.88
Y Y Y Y Y Y 060-BL55120L.88
Y Y Y Y Y Y 060-BL55120H.88
Y Y Y Y Y Y Y 060-BL5512B0.88
Y Y Y Y Y Y Y 060-BL5512BL.88
Y Y Y Y Y Y Y 060-BL5512BH.88
Y Y Y Y Y Y 060-BL5513.88
Y Y Y Y Y Y 060-BL55130L.88
Y Y Y Y Y Y 060-BL55130H.88
Y Y Y Y Y Y Y 060-BL5513B0.88
Y Y Y Y Y Y Y 060-BL5513BL.88
Y Y Y Y Y Y Y 060-BL5513BH.88

9
3D TRASAR Technology for Pre-Boiler Control
Scale Control
Corrosion Stress
Sample Conditioning System Mounting Feedwater pH & Conductivity
Monitor Blowdown
Controller Fluorometer
Lexan SS High Low Relay Box
None Wall Frame High Purity Low Purity None USA Part Number
Shield Enclosure Pressure Pressure
Y Y NA NA Y Y Y 060-BL5420.88
Y Y NA NA Y Y Y 060-BL54200L.88
Y Y NA NA Y Y Y 060-BL54200H.88
Y Y NA NA Y Y Y Y 060-BL5420B0.88
Y Y NA NA Y Y Y Y 060-BL5420BL.88
Y Y NA NA Y Y Y Y 060-BL5420BH.88
Y Y NA NA Y Y Y 060-BL5421.88
Y Y NA NA Y Y Y 060-BL54210L.88
Y Y NA NA Y Y Y 060-BL54210H.88
Y Y NA NA Y Y Y Y 060-BL5421B0.88
Y Y NA NA Y Y Y Y 060-BL5421BL.88
Y Y NA NA Y Y Y Y 060-BL5421BH.88
Y Y NA NA Y Y Y 060-BL5410.88
Y Y NA NA Y Y Y 060-BL54100L.88
Y Y NA NA Y Y Y 060-BL54100H.88
Y Y NA NA Y Y Y Y 060-BL5410B0.88
Y Y NA NA Y Y Y Y 060-BL5410BL.88
Y Y NA NA Y Y Y Y 060-BL5410BH.88
Y Y NA NA Y Y Y 060-BL5411.88
Y Y NA NA Y Y Y 060-BL54110L.88
Y Y NA NA Y Y Y 060-BL54110H.88
Y Y NA NA Y Y Y Y 060-BL5411B0.88
Y Y NA NA Y Y Y Y 060-BL5411BL.88
Y Y NA NA Y Y Y Y 060-BL5411BH.88

10
3D TRASAR Technology for Pre-Boiler Control
Corrosion Stress Control
Corrosion Stress
Sample Conditioning System Mounting Blowdown Feedwater pH & Conductivity USA Part Number
Monitor
Controller Fluorometer Relay
Lexan High Low Cool & Box Low
SS Enclosure None Wall Frame High Purity None 115 VAC/60Hz
Shield Pressure Pressure Depressurize Purity
Y NA Y Y Y NA NA NA NA 060-BL5320.88
Y NA Y Y Y NA NA NA NA 060-BL5321.88
Y NA Y Y Y NA NA NA NA 060-BL5322.88
Y NA Y Y Y NA NA NA NA 060-BL5323.88
Y NA Y Y Y NA NA NA NA 060-BL5310.88
Y NA Y Y Y NA NA NA NA 060-BL5311.88
Y NA Y Y Y NA NA NA NA 060-BL5312.88
Y NA Y Y Y NA NA NA NA 060-BL5313.88
Y NA Y Y Y NA NA NA NA 060-BL5300.88
Y NA Y Y Y NA NA NA NA 060-BL5301.88
Y NA Y Y Y NA NA NA NA 060-BL5302.88
Y NA Y Y Y NA NA NA NA 060-BL5303.88
Y NA Y Y Y NA NA NA NA 060-BL5340.88
Y NA Y Y Y NA NA NA NA 060-BL5341.88
Y NA Y Y Y NA NA NA NA 060-BL5342.88
Y NA Y Y Y NA NA NA NA 060-BL5343.88
Corrosion Stress Sensor Module
Corrosion Stress
Sample Conditioning System Mounting Feedwater pH & Conductivity USA Part Number
Monitor Blowdown
Controller Fluorometer

11
Lexan High Low Cool & Relay Box Low
SS Enclosure None Wall Frame High Purity None 115 VAC/60Hz
Shield Pressure Pressure Depressurize Purity
NA NA Y Y Y NA NA NA NA 060-BL5220.88
NA NA Y Y Y NA NA NA NA 060-BL5221.88
NA NA Y Y Y NA NA NA NA 060-BL5222.88
NA NA Y Y Y NA NA NA NA 060-BL5223.88
NA NA Y Y Y NA NA NA NA 060-BL5210.88
NA NA Y Y Y NA NA NA NA 060-BL5211.88
NA NA Y Y Y NA NA NA NA 060-BL5212.88
NA NA Y Y Y NA NA NA NA 060-BL5213.88
NA NA Y Y Y NA NA NA NA 060-BL5200.88
NA NA Y Y Y NA NA NA NA 060-BL5201.88
NA NA Y Y Y NA NA NA NA 060-BL5202.88
NA NA Y Y Y NA NA NA NA 060-BL5203.88
NA NA Y Y Y NA NA NA NA 060-BL5240.88
NA NA Y Y Y NA NA NA NA 060-BL5241.88
NA NA Y Y Y NA NA NA NA 060-BL5242.88
NA NA Y Y Y NA NA NA NA 060-BL5243.88
3D TRASAR Technology for Boiler Control
Boiler Control
Corrosion Stress
Sample Conditioning System Mounting Feedwater pH & Conductivity
Monitor Blowdown
Controller Fluorometer
Lexan SS High Low Relay Box
None Wall Frame High Purity Low Purity None USA Part Number
Shield Enclosure Pressure Pressure
Y Y NA NA Y Y NA NA NA 060-BL61300.88
Y Y NA NA Y Y NA NA NA 060-BL61310.88
Y Y NA NA Y Y Y NA NA NA 060-BL6130B.88
Y Y NA NA Y Y Y NA NA NA 060-BL6131B.88
Boiler Control Fluorometer Module
Corrosion Stress
Sample Conditioning System Mounting Feedwater pH & Conductivity
Monitor Blowdown
Controller Fluorometer
Lexan SS High Low Relay Box
None Wall Frame High Purity Low Purity None USA Part Number
Shield Enclosure Pressure Pressure
NA Y NA NA Y Y NA NA NA 060-BL60300.88
NA Y NA NA Y Y NA NA NA 060-BL60310.88
NA Y NA NA Y Y Y NA NA NA 060-BL6030B.88
NA Y NA NA Y Y Y NA NA NA 060-BL6031B.88

12
3D TRASAR Boiler Automation – Parts and Accessories
Replacement Probes Part Number Description

Part Number Description 991-05061053.88* O-Ring, PP filter


991-05043242.88 Pressure regulator (SCS)
6035384 Conductivity, blowdown, non- 991-01970443.88 RTD adapter, 1/8” OD tubing x
compensating, replacement probe only 1/4” MNPT, (SCS)
6034004 Conductivity, probe, blowdown, 991-05059831.88 RTD (SCS)
compensating, replacement probe only 500-531062.88 Sample cooler, 1ft2
6035385 Conductivity, low purity feedwater, 991-01868611.88 Union, PVC, 1/4" Soc (for SCS)
replacement probe only 6009052 Valve, ball, PVC, 1/2, FPT, Viton,
6035386 Conductivity, high purity feedwater, T-port (fluorometer outlet)
replacement probe only 991-05045141.88 Valve, ball, SS, 1/4" (SCS sample tap)
060-BT3220.88 Fluorometer only (feed water) 6036191 Valve, ball, SS, PEEK (SCS SS filter)
060-BT3221.88 Fluorometer only (blowdown) 991-05043791.88 Valve, labcock, PVC, 1/4, FPT, EPDM
991-05058542.88 NCSM ORP/RTD replacement (fluorometer inlet)
probe only 991-05060031.88 Valve needle, SS,
991-05058543.88 NCSM reference probe only 991-01841381.88 Valve relief , SS
6035381 pH replacement probe only, high-purity 991-05043157.88 Valve, solenoid, 3000 psi, 120 VAC
(no cable) 991-05043151.88 Valve, solenoid, 1500 psi, 120 VAC
060-TR5411.88 pH replacement probe only, low-purity 991-05043155.88 Valve, solenoid, 500 psi, 120 VAC
(no cable) 991-50431511.88 Valve, solenoid, 3000 psi, 240 VAC
991-05043156.88 Valve, solenoid, 1500 psi, 240 VAC
991-50431510.88 Valve, solenoid, 500 psi, 240 VAC
Spares & Replacement Parts
991-05061052.88 Wrench, PP filter
Part Number Description
NCSM Parts and Accessories
991-05061321.88 Bracket, SS (SCS flow meter)
991-05061451.88 Bracket, SS (SCS 10" PP filter) Part Number Description
991-P01141.88 Clamp, pipe, 1/4" OD, SS (C-plate only)
991-C00745.88 Clamp, pipe, 1/4", black-PA (body only) 6037008 Junction box (for remote NCSM)
991-05059701.88 Clamp, tube, 1/4" OD, alum/SS 6034335* Battery, NCSM pre-amp cable
(complete) 6026028** Insulation wrap, ceramic, 2” x 50'
991-05048871.88 Clamp, tube, 1/4"OD, blue-PP/SS (1 roll supplied with NCSM)
(complete) 6033766* NCSM calibrator, O and –1024 mV
991-19699314.88 Cross, SS, 1/4, FPT, 150# (SCS) 6018909** NCSM Accessory Kit, complete –
060-TR5222.88* Desiccant canister (fluorometer) includes parts listed below
060-TR5223.88* Desiccant indicator (fluorometer) 6018912 Special 14” SS hypodermic needle
991-05061051.88 Filter housing, PP, 10” (SCS) 6018930* 0.1 N KCl Solution, 250 ml bottle
991-05061055.88* Filter, 5 micron, PP, 10” (SCS) 6018931 3.8 M KCl Solution, 250 ml bottle
991-05061056.88 Filter housing, PP, 5” (SCS-optional) 6018911* 10 cc plastic syringe
991-05061057.88 Filter, 5 micron, PP, 5” (SCS-optional) 6031275 BNC BA80 adapter
991-05061711.88 Filter, SS, 2800 psi, complete, 6031276 Cotton tip grease applicators (10/pkg)
200 micron (feedwater) 6018913 Electrode, 1/2” cell, with BNC, for
991-05061713.88 Filter, SS, 2800 psi, complete, calibration
200 micron (blowdown) 6018914 High-vacuum grease, 5.3 oz tube
991-05061712.88* Filter element, 40 micron, SS, 2-1/4”
(feedwater)
Fluorometer Parts and Accessories
991-05061714.88 Filter element, 200 micron, SS, 3-1/4”
(blowdown) Part Number Description
991-05061715.88 Filter element, 200 micron, 2-1/4”
(feedwater) 500-BTSRKIT.88** 3D TRASAR Boiler Startup Kit –
991-05043142.88 Flow meter, 100-1500 cc/min includes the parts listed below
991-05060101.88 Flow switch 500-P0116.88 Beaker, 800 ml, plastic (3 each)
991-19432523.88 Fuse, 10A, 250V, SLO-BLO (main fuse) 500-P2817.88 Flow cell brush, 16”
991-50554318.88* Fuse, 2.5 A, 250V (output relay fuse) 460-S0726.75 Hydrochloric acid, 1:1, 1L bottle
6037161 Gauge, pressure, 0-100 psi (SCS) 500-P2147.88* Syringe, 60cc, plastic (2 each)
991-50588212.88 Gauge, pressure, 0-2000 psi (NCSM) 460-S0980.75* TRASAR 3 Calibration solution, 1L bottle
6037162 Gauge, pressure, 0-3000 psi (NCSM) 500-BTSRKITLA.88 3D TRASAR Boiler Startup Kit, less acid
991-05061373.88 Hose, braided, SS, 1/4" T x 12" LG Notes:
(NCSM to SCS) **Recommended spare part
**Needed for Fluorometer or NCSM calibration. Add to initial system order
13
Cables Part Number Description
Part Number Description 041-CD0100.88 Cooling-Depressurizing System
(post instrument)
991-05058544.88 Cable, 6 ft, NCSM, ORP, REF, stripped
6036362 Tubing, SS, 1/4"OD, pre-insulated
& tinned
(100 ft roll)
6031277 Cable, 6 ft, NCSM, ORP, REF,
160VTG100 VANTAGE® V100
w/pre-amp, stripped & tinned
060-NGG100.88 Wireless gateway with US plan
991-05058545.88 Cable, 6 ft, NCSM, RTD
060-NGG200.88 Wireless gateway International plan
6035382 Cable, 4 ft, pH, high purity
060-BCP100.88 Condensate conductivity probe
(for 6035381)
assembly, (compensating), complete,
060-TR5412.88 Cable, 6 ft, pH, low purity
3/4” SS/black iron
(for 060-TR5411.88)
060-TR0001.88 Cable adapter, USB to RS232
991-03509170.88 Cable, 2-conductor, shielded, for Blowdown Control Accessories
4-20 mA pumps (per ft)
6036776 Cable, 2-pair, AWG22, shielded, for Part Number Description
conductivity probes (per ft)
6033734 Cable, 3-pair, AWG22, shielded, for 060-BDC100.00 3D TRASAR Boiler Controller and
blowdown relay box, wall mount
remote NCSM (per ft)
060-BDP100.88 Blowdown conductivity probe assembly,
6036777 Cable, 4-pair, AWG22, shielded, for
complete, 3/4” SS/black iron
conductivity probe with RTD (per ft)
(non-compensating)
991-05047661.88 Ethernet crossover cable, 6’ orange
060-BDP100C.88 Blowdown conductivity probe assembly,
060-TR5221.88 Fluorometer cable, 4 ft.
complete, 3/4” SS/black iron
060-BT3230.88 Fluorometer cable, 10 ft.
(compensating)
991-05053481.88 Pigtail, 16/3 SJOW, 18” w/US plug
041-BLR012.88 Blowdown control & flow valve package,
991-01928722.88 Service cord, 12/3 SJOW
1/2”
(no termination)
041-BLR034.88 Blowdown control & flow valve package,
3/4”
041-BLR100.88 Blowdown control valve and flow valve
Optional Accessories
package, 1”
Part Number Description 041-BLR008.88 Flow control valve, 1/2”
041-BLR009.88 Flow control valve, 3/4”
060-AT8000.88 Analog Input Module (8 inputs), 041-BLR110.88 Flow control valve, 1”
120 VAC 041-BLR006.88 Motorized valve, SS, 1/2”,
060-BT8002.88 Analog Input Module, (8 inputs), 115 VAC/60 Hz
240 VAC 041-BLR007.88 Motorized valve, SS, 3/4”,
060-AT1000ADD.88 NCSM upgrade kit (field installable) 115 VAC/60 Hz
060-AT1010ADD.88 NCSM, enclosed, upgrade kit 041-BLR010.88 Motorized valve, SS, 1”, 115 VAC/60Hz
(field installable) 060-BDRB04.88 Relay box, 4-relay, 115 VAC/60 Hz
060-HCP100.88 Feedwater conductivity & pH module, 060-BDRBE4.88 Relay box, 4-relay, 230 VAC/50 Hz
high-purity 991-19070215.88 Reducing coupling, 1” FNPT x
060-LCP100.88 Feedwater conductivity & pH module, 3/4” FNPT, black iron
low-purity 001-H07641.88 Conductivity Std, 10,000 μS, 500 mL
460-S0298.75 Conductivity Std, 600 μS, 1000 mL 001-H07642.88 Conductivity Std, 5,000 μS, 500 mL
460-S0743.75 Conductivity Std, 200 μS, 1000 mL 460-S0297.75 Conductivity Std, 3,000 μS, 1000 mL
460-S0299.75 Conductivity Std, 40 μS, 1000 mL
Notes:
460-S0407.75 pH 7 buffer, 1000 mL **Recommended spare part
460-S0408.75 pH 10 buffer, 1000 mL **Needed for Fluorometer or NCSM calibration. Add to initial system order
060-TR5270.88 LAN router
041-HPT1000.88 Sample conditioning system,
1500 psi, 500°F, 120 VAC
041-HPT2000.88 Sample conditioning system,
1500 psi, 500°F, 230 VAC
041-LPT1000.88 Sample conditioning system, 50 psi,
250°F, 120 VAC
041-LPT2000.88 Sample conditioning system, 50 psi,
250°F, 230 VAC

14
15
NALCO COMPANY OPERATIONS
North America: Headquarters –1601 West Diehl Road • Naperville, Illinois 60563 • USA
Energy Services Division – 7705 Highway 90-A • Sugar Land, Texas 77487 • USA
Europe: Ir.G.Tjalmaweg 1 • 2342 BV Oegstgeest • The Netherlands
Asia Pacific: 2 International Business Park • #02-20 The Strategy Tower 2 • Singapore 609930
Latin America: Av. das Nações Unidas 17.891 • 6° Andar 04795-100 • São Paulo • SP • Brazil

www.nalco.com
TRASAR, 3D TRASAR, VANTAGE, Nalco Corrosion Stress Monitor, NALCO and the logo are
Trademarks of Nalco Company
©2008, 2010 Nalco Company All Rights Reserved 3-10