SET FREE mini


VARIABLE REFRIGERANT FLOW
AIR SOURCE HEAT PUMP TYPE
HNSQ SERIES

Company Name

CUSTOMER SERVICE CERTIFICATION

SALES OFFICE

WARRANTY

SPARE PARTS

SOCIAL MEDIA
DISTRIBUTOR

The specifications of this catalog may change without prior notice to allow
Hitachi Cooling & Heating to incorporate the latest innovations for its
customers.
The information contained in this catalog is merely informative.
Find the products of Hitachi
Hitachi Cooling & Heating declines any responsibility in the broadest sense, Cooling & Heating with the best
for damage, direct or indirect, arising from the use and / or interpretation service and conditions at your
of the recommendations in this catalog. Hitachi Distributor

2304-HNSQ-3

Welcome The beauty of balance
No matter what the weather is like outside,
when you're indoors, you want to have complete
control over your environment. At work or play,
awake or asleep, you're free to create your own
atmosphere; balancing energy with calm, sound
with silence and light with shade. It's the same for
cooling and heating.

When the air around you is in balance,


you can enjoy life indoors that much more.

SET FREE mini HNSQ Series


Air. It’s a
wonderful thing.
Living Harmony
Invisible, silent and life-giving, air makes
our entire world possible. It surrounds us, At Hitachi Cooling & Heating we like to think of
continuously energizing, cooling and warming. It this as creating harmony with your interior
can be unpredictable and sometimes challenging, environment. When we achieve that wonderful
but when air is in harmony with us, everything balance, productivity, learning, happiness
seems that much easier. and health can thrive.

This is our vision. We call this ‘Living Harmony’


To create the air that makes life better. and it’s at the center of everything we do.

The future together


Living Harmony puts people first. By balancing
the human needs of our customers with an
uncompromising approach to innovation
and quality, we can continue to create the

WELCOME
technologies for a more comfortable and
balanced world.

Your world. We live in it together.

02

03
Helping you form
an ideal living environment
SET FREE mini is the pinnacle of indoor climate control technology.
Our versatile outdoor units, indoor units, and control devices deliver tailored solutions for every
type of living space, providing a comfortable and enjoyable living environment for all.
With SET FREE mini, we don't just gratify our customers, we transform the lives of architects,
installers, and all those involved in space design.

SET FREE mini HNSQ Series


AESTHETICS DESIGN FLEXIBILITY

• Our innovative design ensures that the outdoor unit • Our outdoor unit provides unparalleled piping flexibility,
blends seamlessly into your surroundings, creating a making the design process easier and installation costs
harmonious aesthetic without any visual distractions for more affordable.
your neighbors. • Thanks to its high-static pressure design, our outdoor
• Our high-capacity outdoor unit allows for a more flexible unit is suitable for a wide range of applications in various
installation process, saving valuable space and ensuring weather and installation conditions.
that your living environment remains uncluttered and • With a diverse range of indoor units, our system can be
spacious. customized to meet the unique needs of any space.
• Our units are both energy-efficient and compact, boasting
a small body with a large capacity to maximize comfort
while minimizing space requirements.

INTRODUCING SET FREE mini


HIGHER PERFORMANCE ADAPTABILITY

• Our cutting-edge technology provides you with higher • Our outdoor unit features a night-shift (low-noise) mode,
efficiency, not only in cooling EER but also in heating making it ideal for residential areas where noise pollution
COP, ensuring that you can enjoy a comfortable indoor is a concern.
environment while reducing energy costs. • Our system can efficiently operate in extreme weather
• Our VRF systems are designed to provide you with greater conditions with ambient temperatures up to 52.0°C for


control over your indoor environment, with individual cooling operations and as low as -20.0°C for heating
controllers and a centralized controller that allow you to operations. This ensures that our units can perform
optimize the energy-saving operation of your HVAC system, consistently and reliably, no matter the weather.
keeping your energy bills under control without sacrificing

Introducing
comfort.

EASY SERVICING EASY INSTALLATION


AND MAINTENANCE AND MAINTENANCE

SET FREE mini • Our outdoor units are equipped with several DIP switches
located in the front for easier test-runs and diagnosis.
This design helps streamline the installation process and
enables quick troubleshooting to minimize downtime,
making it an ideal solution for businesses seeking
• Our slim and lightweight outdoor units make installation a
breeze, allowing installers to complete their work quickly
and efficiently.
• Our H-LINK technology provides flexible connection
options between the centralized controller, outdoor unit,
maximum operational efficiency. and indoor units, allowing for a custom configuration
tailored to your needs.
• Our outdoor unit offers four directions of piping, providing
04
flexibility and ease of installation at any site.
05

LINE UP OVERVIEW

OFFERING YOU FIVE TYPES OF OUTDOOR UNITS


(HP Class/Cooling Capacity/Heating Capacity/Weight)

SET FREE mini HNSQ Series


1,380mm

990mm
800mm

950mm 950mm 320mm 950mm 320mm


320mm

3.0HP Class/8.0KW/9.5KW/74kg 4.5HP Class/12.5KW/14.0KW/87Kg 6.5HP Class/18.0KW/20.0KW/118Kg


3.5HP Class/10.0KW/11.2KW/74Kg 5.0HP Class/14.0KW/16.0KW/87Kg 7.0HP Class/20.0KW/22.4KW/118Kg
4.0HP Class/11.2KW/12.5KW/74Kg 6.0HP Class/15.5KW/17.0KW/87Kg

OUTDOOR UNITS / LINE UP OVERVIEW


1,650mm
1,380mm


Outdoor units 950mm

8.0HP Class/22.4KW/25.0KW/122kg
9.0HP Class/24.1KW/26.0KW/122Kg
320mm 1,100mm 390mm

10.0HP Class/28.0KW/31.5KW/147Kg
11.0HP Class/30.0KW/33.0KW/165Kg
12.0HP Class/33.5KW/37.5KW/165Kg

Unlocking the doors to comfortable living, Hitachi


SUMMARY TABLE
outdoor units come in FIVE types with cutting-edge
HP class HP 3.0-7.0 8.0-12.0
design and enhanced performance. Our intelligently Nominal cooling kW 8.0-20.0 22.4 - 33.5
Capacity
engineered units cater to the diverse air conditioning Connectable indoor unit quantity
Nominal heating kW
unit
9.5-22.4
Up to 10 units
25.0 - 33.0
Up to 19 units
needs of various buildings, no matter the scale or Combination capacity ratio between ODU and IDU (all range)
Total liquid piping length
%
m
50-130
Up to 120m
50-130
Up to 300m
construction. Whether it's a small apartment or Maximum piping length
Between outdoor unit and farthest indoor unit
Between 1st branch multi kit and farthest indoor unit
m
m
Up to 75m
Up to 30m
Up to 100m
Up to 40m
a sprawling commercial complex, we've got you Between multi kit and each indoor unit
Between outdoor unit and indoor units (ODU above IDU)
m
m
Up to 10m
Up to 30m
Up to 15m
Up to 50m
covered. At Hitachi, we believe that comfort is the Maximum level difference Between outdoor unit and indoor units (IDU above ODU) m Up to 30m Up to 40m
Between indoor units m Up to 10m Up to 15m
foundation of a happy life. And we know that this Cooling operation range * °C DB -5.0 to 52.0 -5.0 to 52.0
06
Heating operation range * °C DB -20.0 to 24.0 -20.0 to 23.0
journey begins with our outdoor units. Required branch pipe (multi-kit) - E-102SN
E-102SN (8/9HP)
07
E-162SN (10-12HP)
* For more details, please consult your distributors or dealer, or, refer to technical manuals.
– –
HIGH EFFICIENCY EASY SERVICING AND MAINTENANCE

SETTING THE NEW STANDARD CABINET DESIGNED TO EASE OF WORK


SET FREE mini HNSQ series lifts performance and efficiency to a new level. It can offer a wider range of operating ambient Several DIP Switched in the front of the outdoor units are
temperatures and increased indoor unit combination capacity. designed for easier test-run & diagnosis in the maintenance
Both will reward you with superior performance as well as significant energy and cost savings. occasion. It has several advantages as follows:
• Monitor the unit real-time working status
• Display the fault code
EER: Energy Efficiency Ratio • View the historical fault code
Cooling EER • Optimize the control parameters based on site
(W/W)

SET FREE mini HNSQ Series


5.0
4.00 3.91
4.0 3.71
3.46 3.30 3.42 3.52 3.35 3.41 3.30
3.26 3.16
3.01
3.0

2.0

1.0

0.0
3.0 3.5 4.0 4.5 5.0 6.0 6.5 7.0 8.0 9.0 10.0 11.0 12.0 HP Class

The EER is tested under the following conditions when it is combined with test indoor units.
For EER: I ndoor temperature: 27°C DB/19°C WB; Outdoor temperature: 35°C DB
Pipe length: 10m; Pipe lift: 0m

HIGH EFFICIENCY /EASY SERVICING AND MAINTENANCE


COP: Coefficient Of Performance
Heating COP

(W/W)
5.0
4.20 4.19 4.14 3.99 3.96
3.90
4.0 3.64 3.63 3.62 3.62 3.71
3.41 3.47

3.0

2.0

1.0

0.0
3.0 3.5 4.0 4.5 5.0 6.0 6.5 7.0 8.0 9.0 10.0 11.0 12.0 HP Class

The COP is tested under the following conditions when it is combined with test indoor units.
For COP I ndoor temperature: 20°C DB; Outdoor temperature: 7°C DB/6°C WB
Pipe length: 10m; Pipe lift: 0m

THREE KEY IMPROVEMENTS FOR GREATER EFFICIENCY

Rotary compressor Refrigerant-cooling PCB Self-holding 4-way valve


Wide operation Better reliability Save energy
frequency of 15-120Hz & enhance the reliability 08
DC
09

DESIGN FLEXIBILITY 0Pa

30Pa

HIGH EXTERNAL PRESSURE OF OUTDOOR UNIT FOUR DIRECTIONS OF PIPING IN OUTDOOR UNIT
High external static pressure up to 30Pa is available in order to Front & Right Rear Bottom
avoid air short-circuit conditions. This ensures that the outdoor
unit runs with a good ventilating condition under different
conditions of installation.

SET FREE mini HNSQ Series


0Pa

30Pa
Stop valve built with 4-directional outlet piping for easier pipe installation.
The refrigerant pipes can connect the stop valves from the front and right, rear and bottom of the unit.

PIPING FLEXIBILITY WIDE OPERATION TEMPERATURE RANGE


Longer and more flexible piping has been realized.
This helps in dealing with various piping restrictions. Up to 52.0°C ambient temperature for cooling operations
• Up to 48.0°C stable running
• Up to 52.0°C interval running

Outdoor Air Temperature (°C DB)


52.0
Special fresh air intake and trapezoid heat sink design
Interval Operation Working Range
are adopted for the inverter driver. This improves heat

DESIGN FLEXIBILITY
48.0
emission and allows the system to be running stably
1st branch multi kit under high ambient conditions.
Continuous Cooling
Operation Range

-5.0
Gas pipe Liquid pipe

3 E-102SN (3.0~9.0HP)
E-162SN (10.0~12.0HP) 21.0 32.0
1 Indoor Air Inlet Temperature (°C DB)
4 2
As low as -20.0°C ambient temperature for heating operations
• As low as -15.0°C stable running
24.0

Outdoor Air Inlet Temperature (°C DB)


• As low as -20.0°C interval running (3-7HP)
HNSQ: Special 3-row coil design and larger area of coil 23.0
enhance heating capability. (8-12HP)
This enables heating as low as -20.0°C ambient Continuous Heating
Operation Range
condition even in cold regions.
Maximum piping length
3.0HP Class 3.5-4.0HP Class 4.5-6.0HP Class 6.5-7.0HP Class 8.0-9.0HP Class 10.0-12.0HP Class
Total piping length 30m 40m 70m 120m 300m 250m -15.0
Interval Operation Working Range
1 Between outdoor unit and farthest indoor unit 25m 25m 60m 75m 80m 100m
2 Between 1st branch multi kit and farthest indoor unit 20m 20m 30m 30m 40m 40m
-20.0
Maximum level difference
15.0 27.0 30.0
3.0HP Class 3.5-4.0HP Class 4.5-6.0HP Class 6.5-7.0HP Class 8.0-9.0HP Class 10.0-12.0HP Class (3-7HP) (8-12HP)
ODU above IDU 20m 20m 30m 30m 50m 50m Indoor Air Inlet Temperature (°C DB)
3 Between outdoor unit and indoor units
IDU above ODU 20m 20m 20m 30m 40m 40m
10
4 Between indoor units 3.5m 3.5m 10m 10m 15m 15m
Each maximum length or level difference has several conditions, please refer to the technical documents in inquiry. 11

SPECIFICATIONS

HP Class 3.0 3.5 4.0 4.5 5.0 6.0 6.5 7.0 HP Class 8.0 9.0 10.0 11.0 12.0

Model unit RAS-3.0HNSKQ RAS-3.5HNSKQ RAS-4.0HNSKQ RAS-4.5HNSKQ RAS-5.0HNSKQ RAS-6.0HNSKQ RAS-6.5HNSKQ RAS-7.0HNSKQ Model unit RAS-080HNBSTQ RAS-090HNBSTQ RAS-100HNBSTQ RAS-110HNBSTQ RAS-120HNBSTQ

Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Power Supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50
Cooling kW 8.0 10.0 11.2 12.5 14.0 15.5 18.0 20.0 Cooling kW 22.4 24.1 28.0 30.0 33.5
Capacity Capacity
Heating kW 9.5 11.2 12.5 14.0 16.0 17.0 20.0 22.4 Heating kW 25.0 26.0 31.5 33.0 37.5
Cooling kW 2.00 2.56 3.02 3.61 4.30 5.15 5.46 5.85 Cooling kW 6.36 7.20 8.20 9.10 10.60
Power Input Power Input

SET FREE mini HNSQ Series


Heating kW 2.26 2.67 3.02 3.85 4.41 4.99 5.13 5.61 Heating kW 6.31 7.18 8.70 9.50 10.11
Air Flow Rate Standard m3/min 60 67 71 69 71 71 101 122 Air Flow Rate Standard m3/min 122 122 163 163 163
Dimensions H×W×D mm 800×950×320 800×950×320 800×950×320 990×950×320 990×950×320 990×950×320 1,380×950×320 1,380×950×320 Dimensions H×W×D mm 1,380×950×320 1,380×950×320 1,650×1,100×390 1,650×1,100×390 1,650×1,100×390
Weight Net kg 74 74 74 87 87 87 118 118 Weight Net kg 122 122 147 165 165
Footprint Area m2 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 Footprint Area m2 0.30 0.30 0.43 0.43 0.43
Packaging Volume m3 0.47 0.47 0.47 0.51 0.51 0.51 0.76 0.76 Packaging Volume m3 0.76 0.76 1.13 1.13 1.13
Compressor Type Rotary Rotary Rotary Rotary Rotary Rotary Rotary Rotary Compressor Type Rotary Rotary Rotary Rotary Rotary
Type R410A R410A R410A R410A R410A R410A R410A R410A Type R410A R410A R410A R410A R410A
Refrigerant Refrigerant
Charge Amount kg 2.5 3.1 3.1 4 4 4 5.5 5.9 Charge Amount kg 5.9 5.9 5.5 6.5 6.5
Model α68HES-H α68HES-H α68HES-H α68HES-H α68HES-H α68HES-H α68HES-H α68HES-H Model α68HES-H α68HES-H FW68DA or FVC68D FW68DA or FVC68D FW68DA or FVC68D
Refrigerant Oil Refrigerant Oil
Charge Amount L 0.88 0.88 0.88 1.65 1.65 1.65 1.8 1.8 Charge Amount L 1.8 1.8 2.0 2.0 2.0
Number of Fan Motors 1 1 1 1 1 1 2 2 Number of Fan Motors 2 2 2 2 2
Capacity Ratio of IDU/ODU % 50%~130% 50%~130% 50%~130% 50%~130% 50%~130% 50%~130% 50%~130% 50%~130% Capacity Ratio of IDU/ODU % 50-130% 50-130% 50-130% 50-130% 50-130%
Sound Sound
Semi-anechoic dB(A) 51 54 56 54 54 56 56 58 Semi-anechoic dB(A) 55 56 58 59 59
Pressure Level Pressure Level
Liquid mm φ9.53 φ9.53 φ9.53 φ9.53 φ9.53 φ9.53 9.53 9.53 Liquid mm 9.52 9.52 12.70 12.70 12.70
Piping Piping
Gas mm φ15.88 φ15.88 φ15.88 φ15.88 φ15.88 φ15.88 15.88 15.88 Gas mm 19.05 19.05 22.20 25.40 25.40
Cooling EER W/W 4.00 3.91 3.71 3.46 3.26 3.01 3.30 3.42 Cooling EER W/W 3.52 3.35 3.41 3.30 3.16
Efficiency Efficiency
Heating COP W/W 4.20 4.19 4.14 3.64 3.63 3.41 3.90 3.99 Heating COP W/W 3.96 3.62 3.62 3.47 3.71
Max IDU Connect Qty. 4 5 5 5 6 6 9 10 Max IDU Connect Qty. 12 12 13 16 19

SPECIFICATIONS
Working Cooling Stable Work at -5.0~48.0°C DB and Interval at 48.0~52.0°C DB Working Cooling Stable Work at -5.0~48.0°C DB and Interval at 48.0~52.0°C DB
Temp. Range Heating Stable Work at -15.0~24.0°C DB and Interval at -20.0~-15.0°C DB Temp. Range Heating Stable Work at -15.0~15.5°C DB and Interval at -20.0~-15.0°C
Refrigerant Control Mode Microcomputer-controlled Electronic Expansion Valve Refrigerant Control Mode Microcomputer-controlled Electronic Expansion Valve
Tubing Connection Method Flare Connection Tubing Connection Method Flare Connection
Total Liquid Pipe Total Liquid Pipe
m 30 40 40 70 70 70 120 120 m 300 300 250 250 250
Length Length
Between ODU Between ODU
m 25 25 25 60 60 60 75 75 m 80 80 100 100 100
and farthest IDU and farthest IDU
Maximum Between 1st Maximum Between 1st
Piping Length Branch Multi Kit m 20 20 20 30 30 30 30 30 Piping Length Branch Multi Kit m 40 40 40 40 40
and Farthest IDU and Farthest IDU
Between Each Between Each
Multi Kit and m 10 10 10 10 10 10 10 10 Multi Kit and m 15 15 15 15 15
Each IDU Each IDU

Between ODU m 20 20 20 30 30 30 30 30 Between ODU m 50 50 50 50 50


Maximum Maximum
Level and IDU m 20 20 20 20 20 20 30 30 Level and IDU m 40 40 40 40 40
Difference Difference
Between IDUs m 3.5 3.5 3.5 10 10 10 10 10 Between IDUs m 15 15 15 15 15
1st branch Multi-Kit E-102SN E-102SN E-102SN E-102SN E-102SN E-102SN E-102SN E-102SN 1st branch Multi-Kit E-102SN E-102SN E-162SN E-162SN E-162SN

Notes: Notes:
1. The EER and COP are tested under the following working conditions, when the outdoor unit is connected to the special combination of indoor units. 1. The EER and COP are tested under the following working conditions, when the outdoor unit is connected to the special combination of indoor units.
Working conditions for testing EER Working conditions for testing COP Working conditions for testing EER Working conditions for testing COP
• Indoor temperature: 27.0°C DB/19.0°C WB • Indoor temperature: 20.0°C DB • Indoor temperature: 27.0°C DB/19.0°C WB • Indoor temperature: 20.0°C DB
• Outdoor temperature: 35.0°C DB • Outdoor temperature: 7.0°C DB/6.0°C WB • Outdoor temperature: 35.0°C DB • Outdoor temperature: 7.0°C DB/6.0°C WB
• Pipe length: 10.0 metre • Pipe length: 10.0 metre • Pipe length: 10.0 metre • Pipe length: 10.0 metre
• Pipe lift: 0 metre • Pipe lift: 0 metre • Pipe lift: 0 metre • Pipe lift: 0 metre
2. Noise test conditions are specified below: Noise is tested 1.5 metre above ground level and 1.0 metre away from the surface of the external service 2. Noise test conditions are specified below: Noise is tested 1.5 metre above ground level and 1.0 metre away from the surface of the external service
board on the outdoor unit. Noise parameters are tested in a semi-anechoic chamber. board on the outdoor unit. Noise parameters are tested in a semi-anechoic chamber.
3. Please consult your local distributor for indoor unit combination limitations. 3. P
 lease consult your local distributor for indoor unit combination limitations.

6.5HP,7HP
* Indicates that there are pipe adapters in the outdoor unit, which are used to adjust the gas pipe between the outdoor unit and the first branch.
Thus the φ19.05 diameter pipe is converted to φ22.2 diameter pipe in the model.
** Indicates that there is a pipe adapter in the model, which is used to adjust the gas pipe length between the outdoor unit and the first branch. Thus
the φ19.05 diameter pipe is converted to a φ25.4 diameter pipe.

12

13

VRF INDOOR UNITS We offers a variety of indoor units in
its line-up to achieve comfortable air
conditioning that flexibly addresses
various applications and shapes of
16 SOLUTIONS TO BE MEMORIZED space. By raising the "quality" of the
16 WIDE RANGE OF LINE-UP air, we believe that the "quality" of time
17 GENTLECOOL customers spend there will also be
17 CROWDSENSE enhanced.

SET FREE mini HNSQ Series


18 FEETWARM
20 DIRECT - INDIRECT AIRFLOW CONTROL
20 FLOORSENSE COOL
21 AUTO MOTION-SENSOR CONTROL
21 SETBACK MODE FOR HOTEL APPLICATION

22 IAQ: LIVE AND WORK IN HARMONY


22 ViroSense S filter
23 ViroSense Z2 filter
24 AQtiv-Ion Kit

26 DUCTED
28 HIGH ESP TYPE [RPIH-HNAUN1Q] (AC MOTOR TYPE)
MEDIUM ESP TYPE [RPIM-HNAUN1Q] (AC MOTOR TYPE)

15
29 LOW ESP TYPE [RPIL-HNAUN1Q] (AC MOTOR TYPE)
COMPACT TYPE [RPIZ-HNDTS1Q] (DC MOTOR TYPE)
30 COMPACT TYPE [RPIZ-HNATN1Q] (AC MOTOR TYPE)

VRF INDOOR UNITS


32 CASSETTE
34 Silent-Iconic™ (4-WAY CASSETTE RCI-FSRP DESIGN PANEL)
36 4-WAY CASSETTE TYPE [RCI-FSRP/RCI-FSKDN1Q] (DC MOTOR TYPE)
37 4-WAY CASSETTE COMPACT TYPE [RCIM-FSRE] (DC MOTOR TYPE)
38 2-WAY CASSETTE TYPE [RCD-FSR] (DC MOTOR TYPE)
39 1-WAY CASSETTE TYPE [RCS-FSR] (DC MOTOR TYPE)

40 CONCEALED & EXPOSED


42 WALL MOUNTED TYPE [RPK-FSRM] (DC MOTOR TYPE)
43 WALL MOUNTED TYPE [RPK-HNBUSQ] (DC MOTOR TYPE)
44 FLOOR/CEILING CONVERTIBLE TYPE [RPFC-FSNQ] (AC MOTOR TYPE)
45 CEILING SUSPENDED TYPE [RPC-FSR] (DC MOTOR TYPE)
46 FLOOR CONCEALED TYPE [RPFI-FSNQ] (AC MOTOR TYPE)

47 GENERAL DATA & ACCESSORIES

56 VENTILATIONS

14

15
– –
SOLUTIONS TO BE MEMORIZED SOLUTIONS TO BE MEMORIZED
WIDE RANGE OF LINE-UP TEMPERATURE MANAGEMENT FOR SUPERIOR COMFORT
DUCTED
HIGH ESP TYPE MEDIUM ESP TYPE LOW ESP TYPE COMPACT TYPE GENTLECOOL
(AC MOTOR TYPE) (AC MOTOR TYPE) (AC MOTOR TYPE) (DC MOTOR TYPE)
RPIH-HNAUN1Q RPIM-HNAUN1Q RPIL-HNAUN1Q RPIZ-HNDTS1Q RCI-FSRP RCIM-FSRE RCD-FSR RCS-FSR RPK-FSRM RPC-FSR
(all panels) PC-ARFG1
RCI-FSKDN1Q

∙ Cooling Capacity: ∙ Cooling Capacity: ∙ Cooling Capacity: ∙ Cooling Capacity: Set your comfortable temperature not only for “Room” but also for “Air” in cooling operation. To make your room reach to the desired
8.4-16.0kW ESP: High ESP 2.2-7.1kW ESP: Medium 2.2-16.0kW 2.2-7.1kW Fan air flow rate
(90/120/180Pa) ESP (50/80Pa for 0.8-2.5HP ESP: Low ESP (30Pa for up to 6 taps (DC motor
temperature faster, the discharged air from the indoor unit can be sometimes much cooler, causing discomfort at the beginning of
class) 0.8-2.5HP class, 60Pa for model only) operation. Now, you can choose “discharge air temperature = your own comfort level”, as you like, by our Advanced color wire remote
3.0-6.0HP class) ESP: 10/30Pa
controller PC-ARFG1. You can be in comfort and avoid cold draft from the moment when cooling operation starts, while the room gently
cools down.

SET FREE mini HNSQ Series


COMPACT TYPE
(AC MOTOR TYPE) Potential Discomfort GentleCool No Cold Draft
RPIZ-HNATN1Q

>8.0°C >12.0°C >14.0°C >16.0°C


→ COLD DRAFT
∙ Cooling
 Capacity:
2.2-7.1kW
ESP: 10/30Pa

CASSETTE
4-WAY CASSETTE TYPE (DC MOTOR TYPE) 4-WAY CASSETTE TYPE 4-WAY CASSETTE TYPE
RCI-FSRP (DC MOTOR TYPE) + TWIN-SENSE 4-way Panel
RCI-FSKDN1Q RCI-FSRP+ P-AP160NAE2
RCI-FSKDN1Q+ P-AP160NAE2
Color variation (RCI-FSRP) + OPT-EZJ01 GentleCool: OFF GentleCool: LOW GentleCool: MED GentleCool: HIGH

∙ N
 eutral White, Black, Gray and Beige options ∙ Economic yet efficient ∙ Adaptive comfort for real
∙R
 easonable offering to meet your comfort and operation solution for your life by multiple advanced
CROWDSENSE

SOLUTIONS TO BE MEMORIZED
commercial indoor space comfort settings

Silent-IconicTM 4-WAY CASSETTE COMPACT TYPE 2-WAY CASSETTE TYPE 1-WAY CASSETTE TYPE Adjusting capacity by predicting room temperature changes due to
P-GP160NAP, P-GP160NAPU (DC MOTOR TYPE) (DC MOTOR TYPE) (DC MOTOR TYPE) an increase or decrease in human activity
+ RCI-FSRP RCIM-FSRE RCD-FSR RCS-FSR
The motion and radiant temperature sensors detect changes in the number of people in RCI-FSRP RCI-FSKDN1Q
+ + PC-ARFG1
the area and changes in the heat source and predict changes in room temperature. This P-AP160NAE2 P-AP160NAE2
+
CROWDSENSE feature activated by “Predictive crowd adjustment mode" adjusts the air OPT-EZJ01

conditioning capacity and suppresses fluctuations in room temperature.


∙ The indoor air conditioning ∙ Compact 600×600mm fits ∙ Ideal for long, narrow spaces ∙ Ideal for smaller or narrow
unit that makes a statement a standard ceiling grid, ∙ Install in the center of the spaces, the 1-Way Cassette ∙ It may not be effective when operating multiple indoor units.
without making “noise” allowing it to be easily room, it ventilates length- can be installed in a corner ∙ This feature may not work if the variation in the number of people is minimal or if the heat source is small.
incorporated between ways to provide a consistent or on the window side of ∙ When the room temperature is high and the temperature difference between the radiant temperature of the floor or wall and
lighting panels temperature the room the surface temperature of the human body is small, it may not be possible to estimate the variation in the number of people.
(When the room temperature is about 30° C during the cooling process in summer, etc.)
∙ If the number of people decreases whilst heating is in process, this control will not work.
OTHERS
WALL MOUNTED TYPE WALL MOUNTED TYPE FLOOR/CEILING CEILING SUSPENDED TYPE During the cooling function
(DC MOTOR TYPE) (DC MOTOR TYPE) CONVERTIBLE TYPE (DC MOTOR TYPE)
RPK-FSRM RPK-HNBUSQ (AC MOTOR TYPE) RPC-FSR If there is a lot of change in the number of people, such as
during a meeting, the capacity is adjusted by predicting Target set temperature
RPFC-FSNQ room Change in room
changes in room temperature. Traditional temperature temperature Increase power
control after detection
po w e r
Number of tim e
people Predict room temperature
increase room Target set temperature changes. Increase the power
Predictive temperature in advance, as the number of
∙M
 ore precise and tailored ∙ Economic choice for any ∙ A functional solution ∙ Easily installed in spaces control people increases, to
po w e r suppress the rise in room
comfort fo you type of room for performance and where there is no ceiling temperature
practicality cavity or available floor tim e
∙ Display set-temperature
and operation mode on space
front cover by LED During the heating function
FLOOR CONCEALED TYPE If there is a lot of change in the number of people, such as
(AC MOTOR TYPE) during a meeting, the capacity is adjusted by predicting
room Target set temperature
RPFI-FSNQ changes in room temperature. temperature
Change in room
Traditional temperature Detect and
control po w e r then turn off power

Number of tim e
people Predict room temperature
room Target set temperature changes. Reduce power in
increase
Predictive temperature advance as the number of
control po w e r people increases to prevent 16
the room temperature from
∙ C
 an be installed in floor rising too high
tim e
cavities and walls 17

SOLUTIONS TO BE MEMORIZED
TEMPERATURE MANAGEMENT FOR SUPERIOR COMFORT

FEETWARM
RCI-FSRP RCI-FSKDN1Q
+ + PC-ARFG1
P-AP160NAE2 P-AP160NAE2
INTELLIGENT COMFORT WITH OPTIONAL SENSOR +
OPT-EZJ01
Airflow heat control raises the temperature in the foot area
Activated by [FeetWarm heat air control] in 25
comfort setting, in the heating operation, Start-up motion

Temperature in foot area (°C)


"FEETWARM" feature improves the reaching 20
New control
distance of warm, as well as suctions low Airflow heat control

SET FREE mini HNSQ Series


temperature air in the room efficiently. Effect
15
The temperature in
"FEETWARM" feature raises the temperature the foot area rises
in the foot area compared to conventional by about 2°C.
10 Conventional control
control. In addition, since warm air is blown
downwards in a more effective way, this
5
feature is effective even in a large spaces. 0 10 20 30
Elapsed time (minutes)
Temperature transition in the foot area
(average temperature 30 cm above the floor)

BETTER WARMTH IN THE ROOM

(1) Start-up motion


When the radiant temperature sensor detects that "the area around your feet is cold", 4-way cassette closes two opposite louvers *1 and (2) Temperature unevenness suppression motion
narrows the airflow area, to concentrate the air volume in the other two louvers and make the underflow air stronger*2. When the radiant temperature sensor detects that
This increases the air speed and makes it easier for warm air to reach the floor. Zoom IN
"the area around your feet is NO LONGER cold",
In addition, low temperature air is efficiently suctioned via the center air-inlet grill near the two opposite louvers that are currently closed. this "FEETWARM" feature is shifted from "Start-up
Under this Start-up motion, the operation of this close & underflows in two louvers is changed alternately every 3 minutes, so that the

SOLUTIONS TO BE MEMORIZED
motion" to "Temperature unevenness suppression
temperature of your foot area in the room can be quickly warmed up. motion", which is to circulates the air flow more
*1 Under this "FEETWARM" feature, the gap of closed louver is a bit wider than the gap in operation-off. effectively in order to suppress the temperature
*2 In the case of underflow, the air may hit your body directly, possibly causing you to feel cold a bit.
swing swing
unevenness in the foot area. swing
Zoom IN Zoom IN
4-way cassette operates in Auto-Swing mode by
letting 3 louvers open, while closing only one s
remaining louver.
To do so, 4-way cassette can suction the lower swing swing
swing
cold temperature more efficiently, and, help warm
air circulate inside the room.

Alternately repeat
every 3 minutes
Image:
Effect of temperature unevenness suppression motion (temperature distribution around the foot area)
Image:
20 minutes after
Effect of start-up motion (temperature distribution near the foot area 30 minutes after starting the heating function) [Image based on calculation results]
Start-up Motion temperature unevenness suppression motion
Conventional control New control [FEETWARM" feature (Start-up motion)] [Measurement condition Based on
Hitachi research]
See simulation result under the
following conditions above.
Unit capacity: 80 type, room size:
"height 3.2m, length 6.3m, width
6.3m", indoor initial temperature:
7 °C, outdoor temperature: 7 °C,
indoor airflow temperature: 30 °C
About 2°C rise for 0-5 minutes, Gradually rise from
Foot area 30 °C to 40 °C after 5 minutes, Multi-
is warmed function remote control setting:
up more Airflow heat control "effective / long".
18
quickly! (Note) The effect varies depending on
the size of the room and the load.
Average temperature 30 cm above the floor = 15.4 ° C Average temperature 30 cm above the floor = 17.9 °C 4-Way Cassette Type Feetwarm evenly! 19
– –
SOLUTIONS TO BE MEMORIZED SOLUTIONS TO BE MEMORIZED
TEMPERATURE MANAGEMENT FOR SUPERIOR COMFORT FOR YOUR SMARTER OPERATION

DIRECT - INDIRECT AIRFLOW CONTROL AUTO MOTION-SENSOR CONTROL


RCI-FSRP RCI-FSKDN1Q The optional motion sensor enables extra energy savings by sensing the degree
The presence or absence of human activity is detected through our advanced + + PC-ARFG1
P-AP160NAE2 P-AP160NAE2 of activity in a room and automatically adjusting the air output to suit.
"motion sensor" which can sense the area by 4 zones, and the air flow direction is +
OPT-EZJ01
automatically adjusted for each zone.
The air conditioning sensing area is divided into 4 zones through motion sensor. Each zone corresponds to ONE louver.
Selecting “Indirect" or "Direct" automatically adjusts the direction of the air flow*1 for each zone with human activity. RCI-FSRP RCI-FSKDN1Q RCIM-FSRE RCD-FSR RCS-FSR RPC-FSR
*1 In case of "absence" area , air is blown out the way PC-ARFG1 is set up. (P-AP160NAE2) + (SOR-NEC) (SOR-NED) (SOR-NES) (SOR-NEP) PC-ARFG1
P-AP160NAE2
(Note) Concerning "Motion Sensor" +
· If movement is little even when the room is occupied, "Motion Sensor" may not be able to detect the activity and it can operate as "absence" case. OPT-EZJ01

SET FREE mini HNSQ Series


· If an object with a temperature different from the surrounding temperature is in motion, it may be erroneously detected as human activity.

INDIRECT AIR DISTRIBUTION DIRECT AIR DISTIBUTION Image


Motion sensor

Conditioning the air by horizontal airflow only so that Conditioning the air by Auto-Swing airflow so that
people won't get hit by the direct air blow people can feel the direct cold air
Floor
Horizontal airflow Auto swing 0.8m
Image: during cooling Image: during cooling

swing

Detect human activity

How does it work? <example>


Detects the amount of human activity

SOLUTIONS TO BE MEMORIZED
and activates auto-save.
Detect people Detect people

FLOORSENSE COOL
RCI-FSRP RCI-FSKDN1Q
Detects the temperature near the floor to reduce overcooling + + PC-ARFG1
P-AP160NAE2 P-AP160NAE2
+
OPT-EZJ01
When the room has undergone prolonged cooling, the radiant temperature near the floor
is detected and the air flow is automatically reduced, thus reducing the air conditioning
capacity and preventing overcooling. *1 SETBACK MODE FOR HOTEL APPLICATION
*1 When a group of people return to the room or the room temperature rises due to sunlight, the cooling operation returns to normal. Off set the temperature when the space is not occupied RCI-FSRP RCIM-FSRE RCD-FSR RCS-FSR RPC-FSR
*2 Air flow contact varies depending on the capacity of the indoor unit and the height of the ceiling. reducing the power consumption (all panels) PC-ARFG1
RCI-FSKDN1Q
If the air conditioning unit
is used for a long time, the Detects the temperature
near the floor
Adjusted to reduce overcooling
after detection
Room card A Room card B Room card C Room card D
room gets cold OUT IN OUT IN

move

30.0°C 23.0°C 27.0°C 23.0°C

A Returning to set
30.0°C
temperature when
C room key inserted
27.0°C

STEP1 STEP2 B D
23.0°C
The radiant temperature sensor detects The airflow direction is changed
the temperature near the floor surface that to horizontal flow to reduce direct
20
is lower than the set temperature. air contact.*2 In addition, the air Room card Room card Room card
conditioning capacity is also preserved. in out out 21
02

INDOOR AIR QUALITY
Optional accessory filter
Live and work in harmony
ViroSense Z2 filter
Model: F-160L-ZV
ViroSense Z2 filter can help reduce the risk of secondar sollution and
Hitachi IAQ accessory Line-up infection in a room. We have confirmed the proven effect that can
ViroSense Z2 filter inhabits certain viruses attached to the air conditioner's filter already
01 ViroSense S filter 02 ViroSense Z2 filter 03 AQtiv-Ion Kit before.and in 2022, we have confirmed that it can inihibit the SARS-
Optional upgrade​ Optional upgrade​ CoV-2 as well under the laboratory test.
Type of purchase​ Now fitted as standard​
Model: F-160L-ZV Model: JK-LAZQ

∙ want to reduce the risk of ∙ Looking for low-maintenance non-


∙ want to save additional cost​ secondary infection/pollution​reduce intrusive ways of purifying air without BENEFITS

SET FREE mini HNSQ Series


For those who…​ ∙ want to create the cleaner spread of SARS-CoV-2​ installing separate purification units​
indoor environment​ ∙ don’t want to compromise airflow or ∙ Looking for both pollutant and odor

4
additional noise​ reduction solutions​
∙ Lasts up to 6 years (15000h)
∙ Lasts up to 4 years (10000h)
∙ Generates negative ions and emits through
∙ Lasts up to 5 years (12500h) ∙ Quick & easy to install/change from existing
AC airflow, which binds to pollutants and
filters
∙ Anti-virus (>99% inhibition) odors, sending them harmlessly to the floor
Key Features​ ∙ Anti-virus (>99.7% inhibition): better than
∙ Anti-bacteria (>99% inhibition) ∙ Plug & play; converts your ducted IDU into
Ion filter
an air-purifying IDU SARS-CoV-2 Virus Inhibition Bacteria removal Life span of Quick anti-virus
∙ Anti-mold (100% growth stop) ∙ Anti SARS-CoV-2 (>99.9% inhibition)
∙ Up to 96.85% capturing of Influenza virus Inhibition by by over 99.7% by over 99% up to 4 years transformation

01
∙ Anti-bacteria (>99% inhibition)
∙ Up to 74.90% removal of Formaldehyde over 99.9% The efficiency of Efficiency of With regular Your existing 4-way
The efficiency of the ViroSense Z2 ViroSense Z2 filter maintenance and cassette panel can be
the ViroSense filter against certain against Certain types cleaning of the filter, quickly aadapted for the
Z2 filter against viruses has been of Bacterial has been the filter can have a anti-virus version, once
Standard-equipped filter SARS-CoV-2 been confirmed with confirmed too with life span of you change your existing
ViroSense S filter confirmed with inhibition rate up
to more than 99.7%.
inhibition rate up to
more than 99%.
up to 4 years. filter to the ViroSense Z2
filter. The same, usual
inhibition rate up to
We have renewed our standard air filter for some of our Hitachi VRF indoor units with an leading-edge ion-technology, more than 99.9%. attachment!
and, now it has THREE benefits for you & more assures indoor environment.
Our STANDARD Air Filter with Ion Purification feature, ViroSense S filter, will catch & reduce them, then help create the cleaner indoor

INDOOR AIR QUALITY


environment.
ANTI-VIRUS ANTI-BACTERIA ANTI-MOLD EFFICIENCY PROVEN

Anti SARS-CoV-2 Anti Virus


7.0 [Testing data]

Common logarithm average of


6.0 Testing Laboratory: Japan Textile Products Quality and Technology Center
6.01 Test Report No. : 20KB-070036
5.0 Mv = 3.7

infectivity for filter type


Tested Target: Feline infectious peritonitis virus ATCC VR-2127
4.0 Test Procedure: Based
 on ISO 18184; Textiles -- Determination of antiviral activity of
over 99% Inhibition over 99% Inhibition 100% growth stop
3.0 99.9% textile products
Effect: Antiviral activity value (Mv) is at least 2.6 (>99.7% inhibition ratio)
Testing information reduction!
2.0 2.30
[Anti-virus test] [Anti-bacterial test] [Anti-mold test] 1.0
Test Laboratory: Guangdong Detection Center of Microbiology Test Laboratory: G
 uangdong Detection Center of Microbiology Test Laboratory: Guangdong Detection Center of Microbiology 0.0
Test Report # 2021FM05008R01 Test Report # 2021FM05005R01 Test Report # 2021FM05006R01 Immediately After contacting Anti Bacteria
Test Procedure: Based on ISO 18184:2019 Test Procedure: Based on JIS Z 2801:2010 Test Procedure: Based on JIS Z 2911:2018 (A) after inoculation for 8h
Textiles - Determination of antiviral activity of textile products Antibacterial products-Test for antibacterial activity and efficacy [lg (Va)] [lg (Vc] [Testing data]
Methods of test for fungus resistance
Testing Laboratory: Kaken Test Center
[Testing data] Test Report: OS-20-09344-1
UNIT STANDARDIZED WITH VIROSENSE S FILTER Testing Laboratory: Japan Textile Products Quality and Technology Center Test target: (1) Staphylococcus aureus ATTC 6538 (2) Klebsiella pneumoniae ATTC 4352
Test Report No. : 21KB080432-1 Test procedure: I SO 20743:2013 (Textiles - Determination of antibacterial activity of
Test Procedure: ISO 18184 : 2019 "Textiles -- Determination of antiviral activity of textile textile products)
4-way Cassette
4-way Cassette (RCI-FSRP) products." application Effect: Antibacterial activity ratio is at least (1) 2.6 (>99% death ratio) (2) 3.1 (>99.9%
(RCI-FSKDN1Q) Tested Virus: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) death ratio)
TWIN-SENSE Standard Standard Silent-Iconic TWIN-SENSE
Silent-Iconic Silent-Iconic
4-way Panel 4-way Panel 4-way Panel Auto-elevating grille 4-way Panel
White White Black White White Black White

COMPATIBLE INDOOR UNITS WITH VIROSENSE Z2 FILTER


4-way Cassette (RCI-FSRP) 4-way Cassette (RCI-FSKDN1Q)
P-AP160NAE2 TWIN-SENSE Standard Standard Silent-Iconic TWIN-SENSE
P-AP160NAE2 P-AP160NA3 P-AP160KA3 P-GP160NAP P-GP160NAPU P-GP160KAP Silent-Iconic Silent-Iconic Standardized Panel
+ OPT-EZJ01 4-way Panel 4-way Panel 4-way Panel Auto-elevating grille 4-way Panel
White White Black White White Black - White
2-way Cassette (RCD-FSR) 1-way Cassette (RCS-FSR) Ceiling Suspended (RPC-FSR)

22
(Standard P-AP160NAE2
P-AP160NAE2 P-AP160NA3 P-AP160KA3 P-GP160NAP P-GP160NAPU P-GP160KAP 23
P-AP90DNA/P-AP160DNA P-AP36CNA/P-AP56CNA/P-AP80CNA RPC-1.5FSR~6.0FSR Equipped) + OPT-EZJ01

Note: for the additional filter purchase, it is treated as "service part". Please consult your distributors.
03

INDOOR AIR QUALITY AQTIV-ION KIT DEACTIVATION PERFORMANCE

Live and work in harmony SARS-CoV-2 Escherichia coli Influenza virus Staphylococcus aureus PM2.5 Formaldehyde Ammonia

Optional accessory filter


AQtiv-Ion Kit -99.9% -96.64% -96.85% -93.88% -94.46% -74.90% -73.20%
(Inhibition rate) (Inhibition rate) (Removal rate) (Inhibition rate) (Removal rate) (Removal rate) (Removal rate)
Model: JK-LZAQ
Combine your air conditioner with AQtiv-Ion Kit,
AQTIV-ION KIT APPLICATIONS
and provide a better and healthier indoor environment. AQtiv-Ion Kit

Efficient combination with air conditioning


As AQtiv-Ion Kit is integrated into the air conditioning system, AQtiv-Ion Kit does not require its own fan, but uses the airflow from the air

SET FREE mini HNSQ Series


conditioner instead. That means, your new air purification device has minimal impact on the noise level and energy consumption, as it
fits inside the pre-installed air conditioner.

Classroom Condominium Meeting Room Hotel

COMMON FACTORS AFFECTING INDOOR AIR QUALITY


HOW TO INSTALL? (1) Inside the indoor unit (air outlet) (2) Inside the air duct (air outlet)

Plug and play!


Up to your installation condition, Electric
Box
you can choose from two options Air duct Air duct
(outlet) (inlet)

Various pathogenic factors Breeding of bacteria, mold Formaldehyde, ammonia, Second-hand smoking and  ust and mites from fabrics,
D for AQtiv-Ion Kit to be fixed to. suspended-ceiling

including bacteria and certain and damage to household benzene and a variety of volatile kitchen oil fume. such as beddings and pet
viruses caused by insufficient items, allergies caused by high organic compounds released by dander might cause allergies.
ventilation. humidity in wet season. decoration materials.

HOW AQTIV-ION KIT WORKS TECHNICAL SPECIFICATIONS TESTING

INDOOR AIR QUALITY


Model JK-LZAQ [Escherichia coli] [Staphylococcus aureus]
Wiring Length 1 meter Laboratory Guangdong Detection Center of Microbiology
Testing standard GB 21551.3-2010 Appendix A
Rated power supply 220~240V, 50/60Hz
Test Report 2019FM10157R01
Inactivation of Up to 96.85% Down to Removal of Active oxygen Electrical Power consumption (Max) 3W
SARS-CoV-2 by capture of certain PM0.3 micro pollutants generation [PM2.5]
Operating temperature -10~50 °C
more than 99.9% viruses and bacteria particle removal Laboratory Guangdong Detection Center of Microbiology
Operating humidity 20~80%RH Testing standard APIAC/LM 01-2015
Value of negative ion amount 15,000,000 pcs/cc Test Report 2019FM10157R02

AQTIV-ION KIT TECHNOLOGY Certification CE/CB [Infruenza virus]


Laboratory Guangdong Detection Center of Microbiology
The AQtiv-Ion Kit generates negative ions, which
Testing standard Regulation of disinfection technique in healthcare
when released into the air, combine with the oxygen Fight Against The Multiple Invisibles settings <2002, 2-1-3>
(O2) naturally present in the air. These newly created Test Report 2019FM10157R03
AQtiv-Ion Kit
oxygen molecules trap the impure particles, certain
[Formaldehyde] [Anmonia]
viruses and bacteria and deactivate them. Highly-efficient purification
Laboratory Guangdong Detection Center of Microbiology
Testing standard QB/T2761-2006 etc
Abundant, active oxygen ions Test Report 2019FM10157R04
PM2.5 Dust mite up to 15,000,000 pcs/cc
Please consult your Hitachi Cooling & Heating representative for more details
concerning the test reports.

Pollen and
other allergens
Pollutants safely decompose
Inhibit and eliminate
Bacteria & Certain Viruses
COMPATIBLE INDOOR UNITS WITH AQTIV-ION KIT
HIGH ESP (AC) MEIDIUM ESP (AC) LOW ESP (AC) COMPACT (AC) COMPACT (DC)
AQtiv-Ion Kit The free Negative Formaldehyde Smog
RPIH-**HNAUN1Q RPIM-**HNAUN1Q RPIL-**HNAUN1Q RPIZ-**HNATN1Q RPIZ-**HNDTS1Q
releases high- electrons oxygen ions are
Mold Virus
speed electrons collide with O2 created, ready
into the room. molecules. to capture and
Benzene, ketone Ammonia and
inhibits the air and other other odors 24
impurities. Bacteria volatile organic
compounds
(*) For RPI-8.0/10.0FSNQH, please fix the AQtiv-Ion Kit to the indoor unit air-outlet. 25

DUCTED

KEY INFORMATION FEATURES COMPARISON


HIGH ESP TYPE MEDIUM/LOW ESP TYPE COMPACT TYPE COMPACT TYPE
(AC motor) (AC motor) (DC motor) (AC motor)

Model

HIGH ESP TYPE (AC MOTOR TYPE) MEDIUM ESP TYPE (AC MOTOR TYPE) LOW ESP TYPE (AC MOTOR TYPE) RPIM-HNAUN1Q
RPIH-HNAUN1Q RPIZ-HNDTS1Q RPIZ-HNATN1Q
RPIL-HNAUN1Q
[RPIH-HNAUN1Q] [RPIM-HNAUN1Q] [RPIL-HNAUN1Q]
∙ High ESP (90/120/180Pa) ∙ Medium ESP (50/80Pa for 0.8-2.5HP class) ∙ Low ESP (30Pa for 0.8-2.5HP class, 60Pa for 3.0-6.0HP class) Temperature Setting Rate 1.0°C 1.0°C 1.0°C 1.0°C
∙ Space saving design thanks to a height of only 300mm ∙ Space saving design thanks to a height of only 270mm ∙ Space saving design thanks to a height of only 270mm (0.8-
∙ Compatible with AQtiv-Ion Kit (Optional accessory) ∙ Compatible with AQtiv-Ion Kit (Optional accessory) 2.5HP class) or 350mm (3.0-6.0HP class) Indoor Fan Speed 3 taps 3 taps 6 taps 3 taps

SET FREE mini HNSQ Series


∙ Compatible with AQtiv-Ion Kit (Optional accessory)
Louver Direction - - - -

Individual Louver Setting - - - -

Auto Louver Setting - - - -

Dry mode Availability

Setback (Away Function) - - - -


COMFORT
COMPACT TYPE(DC MOTOR TYPE) COMPACT TYPE (AC MOTOR TYPE) Cold Draft Prevention Availability (*1)(*4)
[RPIZ-HNDTS1Q] [RPIZ-HNATN1Q] Comfort setting Control Cool Air (GentleCool) (*2) - - - -
∙ Ideal for installation over the closet or windows thanks to the ∙ Ideal for installation over the closet or windows thanks to the
up to the compactness with 192mm height up to the compactness with 192mm height
∙ Drain-pump with 900mm lift as standard optional part ∙ Drain-pump with 900mm lift as standard optional part Direct/Indirect louver direction in COOL - - - -
∙ Quiet operation level (as low as 20dB(A)) ∙ Quiet operation level (as low as 20dB(A))
∙ Fan air flow rate up to 6 taps (DC motor model only) ∙ Compatible with AQtiv-Ion Kit(Optional accessory) Direct/Indirect louver direction in HEAT - - - -
∙ Compatible with AQtiv-Ion Kit (Optional accessory)
FeetWarm air flow control - - - -

FloorSense Cool air flow control - - - -

Power Saving with Motion Sensor (*2) - - - -

Outdoor Unit Peak cut control - - - -


capacity
control (*2) moderate control - - - -

COMPARISON POWER-SAVING Indoor Unit


Rotation
Indoor Unit Address - - - -

Control (*2) Indoor Air Temperature difference - - - -

IDU Category Cooling (kW) 2.2 2.8 3.6 4.0 4.3 5.0 5.6 6.3 7.1 8.0 8.4 9.0 11.2 14.0 14.2 16.0

DUCTED
Automatic Fan Operation

HIGH ESP TYPE(AC MOTOR TYPE) Quick Function (*2) - - - -


[RPIH-HNAUN1Q]
Daylight Saving Time

MEDIUM ESP TYPE(AC MOTOR TYPE) Power Consumption visualization (*2) - - - -


[RPIM-HNAUN1Q] MENU
Weekly Schedule Setting
DUCTED

LOW ESP TYPE (AC MOTOR TYPE) Power-Saving Setting (*2) - - - -


[RPIL-HNAUN1Q]
Dirty Filter Notice Availability

COMPACT TYPE (DC MOTOR TYPE) Sensor Condition Check


[RPIZ-HNDTS1Q]
Model Display (*2) - - - -
Check Menu
COMPACT TYPE (AC MOTOR TYPE) MAINTENANCE
Indoor/Outdoor PCB Check
[RPIZ-HNATN1Q]
Alarm History Display

Motion Sensor - - - -
PC-RLH11 PC-RLH11 PC-RLH11 PC-RLH11
Receiver Kit for wireless remote controller
PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1
DUPI-131Q
Drain-up mechanism availability DUPI-361Q (*3) (*3)
DUPI-361Q
OPTIONAL KW-PP5Q KW-PP5Q
ACCESSORY KW-PP7/
Air filter KW-PP9/10Q KW-PP6Q KW-PP6Q
8/9/10Q
KW-PP12Q KW-PP12Q
AQtiv-Ion Kit

(*1) This function is utilized to prevent cold discharged air at start-up of heating operation,
after defrosting operation, etc.
AQtiv-Ion Kit
Leads to the better Indoor Air Quality
(*2) Advanced wired remote controller PC-ARF1 needs to be connected.
(*3) Included as standard equipment. Features
∙Up to 96.85% capture of viruses and bacteria
(*4) Please consult your distributor.
∙Down to PM0.3 micro particle removal
∙Pollutant removal
∙Active oxygen generation
26
∙Inactivation of SARS-CoV-2 by more than 99.9%
27

DUCTED

HIGH ESP TYPE (HIGH EXTERNAL STATIC PRESSURE TYPE) LOW ESP TYPE (LOW EXTERNAL STATIC PRESSURE TYPE)
(AC MOTOR TYPE) [RPIH-HNAUN1Q] (AC MOTOR TYPE) [RPIL-HNAUN1Q]

FEATURES AND BENEFITS FEATURES AND BENEFITS


1) High ESP (90/120/180Pa) L-shaped space U-shaped space 1) Low ESP (30Pa for 0.8-2.5HP class, 60Pa for 3.0-6.0HP class) 3) Optional Drain Pump
2 )Space saving design thanks to a height of only 2) Space saving design thanks to a height of only 270mm Drain-up mechanism can be
300mm supplied as optional part.
(0.8-2.5HP class) or 300mm (3.0-6.0HP class)
3) Flexible installation

SET FREE mini HNSQ Series


options allow for multiple configurations

Maximum
900mm

4) Optional Drain Pump


Drain-up mechanism can be supplied as optional part.

Maximum
900mm

COMPACT TYPE
(DC MOTOR TYPE) [RPIZ-HNDTS1Q]

DUCTED
FEATURES AND BENEFITS
1) Ideal for installation over the closet or windows thanks to the up to the compactness with 192mm height
2) Drain-pump with 900mm lift as standard optional part
3) Quiet operation level (as low as 22.5dB(A))

MEDIUM ESP TYPE (MEDIUM EXTERNAL STATIC PRESSURE TYPE) 4) Fan air flow rate up to 6 taps (DC motor model only)

(AC MOTOR TYPE) [RPIM-HNAUN1Q]

FEATURES AND BENEFITS


1) Medium ESP (50/80Pa for 0.8-2.5HP class) 3) Optional Drain Pump
2) Space saving design thanks to a height of only Drain-up mechanism can be supplied as optional part.
270mm

Maximum
900mm

Over the closet In dropped ceiling, over window

28

29
– –
DUCTED Success
that sparks
COMPACT TYPE
(AC MOTOR TYPE) [RPIZ-HNDTN1Q]
Information
Labs Tower Cyprus
FEATURES AND BENEFITS FFOTI PITTA 4, CYPRUS, 1065
https://labstower.cy/
1)Ideal for installation over the closet or windows thanks to the up to the compactness with 192mm height
2) Drain-pump with 900mm lift as standard optional part General Information
Year of installation : 2022
3) Quiet operation level (as low as 20dB(A))
Project type : Retrofit
4) Fan air flow rate up to 6 taps (DC motor model only) Vertical application: Commercial multi-tenant building

SET FREE mini HNSQ Series


Installed unit :
Total 384HP With all Ducted Indoor Units

Over the closet In dropped ceiling, over window

DUCTED
30

31

CASSETTE

KEY INFORMATION FEATURES COMPARISON


4-WAY CASSETTE TYPE 4-WAY CASSETTE 2-WAY 1-WAY
(DC MOTOR TYPE) COMPACT TYPE CASSETTE TYPE CASSETTE TYPE
(DC MOTOR TYPE) (DC MOTOR TYPE) (DC MOTOR TYPE)
Silent-IconicTM
Model
RCI-FSRP RCI-FSKDN1Q RCIM-FSRE RCD-FSR RCS-FSR
Twin-Sense panel Color variation (RCI-FSRP) Twin-Sense panel
(P-AP160NAE2) (P-AP160NAE2) Temperature Setting Rate 0.5°C/1.0°C 0.5°C/1.0°C 0.5°C/1.0°C 0.5°C/1.0°C 0.5°C/1.0°C
Indoor Fan Speed 4 taps 4 taps 4 taps 4 taps 4 taps
4-WAY CASSETTE TYPE(DC MOTOR TYPE) 4-WAY CASSETTE TYPE(DC MOTOR TYPE)
[RCI-FSRP] [RCI-FSKDN1Q] Louver Direction 7 (*4) 7 (*4) 7 (*4) 7 (*4) 7 (*5)
(with P-AP160NAE2) Silent-IconicTM ∙ With area of air distribution with 7 direction of louvers Individual Louver Setting -

SET FREE mini HNSQ Series


∙ Greater performance & Greater comfort can be achieved (distribution with distance available with optional parts (duct Auto Louver Setting
(with P-GP160NAP)
with Elevation Grille flange))
∙ Award-winning Silent-IconicTM to fit your indoor aesthetics. ∙ Individual four-way louvres for greater comfort for individual Dry mode Availability
∙We have also Black type Silent-IconicTM, and, Gray/Beige users Setback (Away Function)
normal panel. ∙ Ideal for a higher ceiling location for installation (up to 5.5m in
cooling mode) Cold Draft Prevention Availability (*1)
(with P-GP160NAPU)
∙ Maintenance will be enormously improved by the auto- ∙ Setback temperature control available, leading to better Comfort setting Control Cool Air (GentleCool) (*2)
operation.
elevation grille. Direct/Indirect louver direction in COOL - - -
∙ Compatible with ViroSense Z2 filter! ∙ GentleCool control to ensure you are not bothered by cold draft COMFORT
∙ Compatible with ViroSense Z2 filter! Direct/Indirect louver direction in HEAT - - -
∙ ViroSense S filter as standard!
FeetWarm air flow control - - -
FloorSense Cool air flow control - - -
P-AP160NAE2
P-AP160NA3 Standard
P-AP36CNA
P-AP160KA3 Decoration panel P-AP90DNA
ViroSense S filter as standard - P-AP56CNA
P-GP160NAP P-AP160DNA
P-AP80CNA
P-GP160NAPU P-AP160NAE2
P-GP160KAP
Power Saving with Motion Sensor (*2)
Outdoor Unit Peak cut control
capacity
4-WAY CASSETTE COMPACT TYPE(DC MOTOR TYPE) 2-WAY CASSETTE TYPE(DC MOTOR TYPE) 1-WAY CASSETTE TYPE(DC MOTOR TYPE) control (*2) moderate control
[RCIM-FSRE] [RCD-FSR] [RCS-FSR] Indoor Unit Indoor Unit Address
∙ Made to give you greater design flexibility as the dimensions fit ∙ Motion sensor available for better energy saving operation ∙ Motion sensor available for better energy saving operation POWER-SAVING Rotation
600mm×600mm architectural module ceiling specifications ∙ Ideal for a higher ceiling location for installation (up to 4.6m in ∙ Optimum air flow conditions are created by either downward Control (*2) Indoor Air Temperature difference
∙ Quiet operation level (as low as 24.5dB(A)) cooling mode) air discharge or frontal air discharge (via optional grille)
∙ Wide range of air flow rate ideal for high ceiling installation ∙ Individually operated louvers give room occupants more or a combination of both Automatic Fan Operation
with 4.6m air blow down in cooling mode comfort ∙ Quiet operation level (as low as 27dB(A)) Quick Function (*2)
∙ Setback temperature control available, leading to better ∙ Quiet operation level (as low as 27dB(A)) ∙ Setback temperature control available, leading to better -
operation. ∙ Setback temperature control available, leading to better operation.
Daylight Saving Time
∙ Motion sensor available for better energy saving operation operation. ∙ GentleCool control to ensure you are not bothered by cold draft Power Consumption visualization (*2)
∙ GentleCool control to ensure you are not bothered by cold draft ∙ GentleCool control to ensure you are not bothered by cold draft ∙ ViroSense S filter as standard! Weekly Schedule Setting
MENU
∙ ViroSense S filter as standard!
Power-Saving Setting (*2)

CASSETTE
Dirty Filter Notice Availability
Sensor Condition Check
Model Display (*2) - -
Check Menu
MAINTENANCE
Indoor/Outdoor PCB Check
Alarm History Display
Colored Decoration Panel availability (*6) - - (*6) (*6)

COMPARISON Motion Sensor


Receiver Kit for wireless remote controller
P-AP160NAE2
PC-ALH3
P-AP160NAE2
HR4A10NEWQ
SOR-NEC
P-AP56NAMR
SOR-NED
PC-ALHD1
SOR-NES
PC-ALHS1
PC-ALH3 PC-ALHC1
Drain-up mechanism availability (*3) (*3) (*3) (*3) (*3)
IDU Category Cooling (kW) 2.2 2.8 4.0 5.6 6.3 7.1 8.0 11.2 14.0 16.0
Flesh air intake accessory (*7) - (*7) (*7) (*7)
4-WAY CASSETTE TYPE P-AP160NAE2 P-AP36CNA
P-AP56NAM P-AP90DNA
(DC MOTOR TYPE) Decoration Panel P-AP160NA3 Standard P-AP56CNA
P-AP56NAMR P-AP160DNA
[RCI-FSRP] P-AP160KA3 P-AP80CNA
P-GP160NAP
4-WAY CASSETTE TYPE Design Panel Silent-Iconic P-GP160NAPU - - - -
(DC MOTOR TYPE) OPTIONAL P-GP160KAP
ACCESSORY P-AP160NAE2
[RCI-FSKDN1Q]
P-AP160NA3 Standard
CASSETTE

4-WAY CASSETTE COMPACT TYPE P-AP160KA3 Decoration panel


ViroSense Z2 filter (optional) compatible with - - -
(DC MOTOR TYPE) P-GP160NAP
P-GP160NAPU P-AP160NAE2
[RCIM-FSRE]
P-GP160KAP
2-WAY CASSETTE TYPE F-90MD-K1
F-71L-D1
F-160MD-K1
(DC MOTOR TYPE) Normal Air Filter F-160L-D1 - -
B-90HD (filter box)
[RCD-FSR] B-160H3 (filter box)
B-160HD (filter box)
1-WAY CASSETTE TYPE
(DC MOTOR TYPE) (*1) This function is utilized to prevent cold discharged air at start-up of heating operation,
after defrosting operation, etc. ViroSense S filter
[RCS-FSR]
(*2) Advanced wired remote controller PC-ARF1 needs to be connected. Features
(*3) Included as standard equipment. ∙New filter as satndard
∙Lasts up to 5 years (12500h)
(*4) 7 steps are avilable by individual louver setting. 5 steps only in the operation of Cooling or Dry.
∙Anti-virus (>99% inhibition)
(*5) 5 steps only in the operation of Cooling or Dry. ∙Anti-bacteria (>99% inhibition)
(*6) 3 colors available (Beige, Grey and Black). ∙Anti-mold100% growth stop)
(*7) Optional parts: Duct Adapter is availbale. Please consult your distributor.
ViroSense Z2 filter
Features
∙Optional Accessory 32
∙Lasts up to 4 years (10000h)
∙Quick & easy to install/change from existing filters 33
∙Anti-virus (>99.7% inhibition): better than Ion filter
∙Anti SARS-CoV-2 (>99.9% inhibition)
– –
CASSETTE Success
that sparks
SILENT-ICONICTM 4-WAY CASSETTE DESIGN PANEL
Exclusive panel: architectural designers will love it! Shop information
Dondi Salotti
Via Camillo Cavour 57 Gaglianico, Biella, Italia
dondisalotti.com

General Information
Year of installation : 2022
Project type : Retrofit

SET FREE mini HNSQ Series


Vertical application: Furniture shop
Installed unit : T
 otal 32HP, (10 units of SIlent-Iconic 4-way Cassette)

[Silent-Iconic] receives Red Dot: Best of the Best


for ground-breaking design quality

The design is well-matched to the space


It is designed to harmonize with the space by creating the central
part to be a blind shaped air-inlet port and reducing its occupied
iF Design Award 2020 Good Design Award
Award Winning (Category: Equipment and presence by darkening the air-outlet port.
(Discipline: Product) facilities for professional use)

Tomohiko Sato
Hitachi, Ltd. Product Design Department, Senior Designer
The designer graduated from University
in the United Kingdom and soon after,
he joined a London based design studio,
working across a wide variety of disciplines The air-outlet port
including furniture, interior and the public with occupied

CASSETTE
realm. Currently, he dedicates himself to air
presence suppression
conditioning design, working as a Senior
Designer in the Hitachi product design Blind shaped
department in Hitachi, Ltd.
air-inlet port

34

35

CASSETTE

4-WAY CASSETTE TYPE 4-WAY CASSETTE COMPACT TYPE


(DC MOTOR TYPE) [RCI-FSRP, RCI-FSKDN1Q] (DC MOTOR TYPE) [RCIM-FSRE]

DECORATION PANEL LINE-UP FEATURES AND BENEFITS

Normal Smart Asthetics Maintenance 1) Compact


TM
with motion sensor Color Panel Silent-Iconic Suspension Ceiling System
Standard
+ radiant temperature sensor Design Panel with Elevation Grille 600mm×600mm
P-AP160NA3 P-AP160NAE2 - P-GP160NAPU
Standard (Custom Order)

SET FREE mini HNSQ Series


Beige Gray Black

Silent-IconicTM
570 mm

White Black
P-GP160NAP P-GP160KAP

Standard
(H×W×D) 40×950×950(mm) 570 mm
(H×W×D) 40×950×950(mm) (H×W×D) 40×950×950(mm) (H×W×D) 52×950×950(mm)
Silent-IconicTM
(H×W×D) 52×950×950(mm)
RCI-FSRP
RCI-FSRP RCI-FSRP RCI-FSRP
RCI-FSKDN1Q

Twin-Sense Cassette

37
Adaptive comfort for real life
The compact 600×600mm footprint fits a standard ceiling grid, allowing it to be easily
incorporated between lighting panels, being ideal for the small place installation!

CASSETTE
GENTLECOOL FEETWARM
>16.0°C
2) Top-class silent operation IDU Capacity HP(Class) 0.8 1 1.5 2 2.5
(standard feature) To make your room (with radiant temperature sensor)
As quiet as gentle breeze
reach to the desired temperature optimization of IDU air flow direction
Sound pressure level (dB(A)) 24.5 24.5 27.5 31 35
faster, the discharged air from the during heating mode by to make
*Air flow rate: Lo
indoor unit can be sometimes much sure that leg zone is consistently 20dB(A) 30dB(A) 40dB(A)
cooler, causing discomfort at the heated CLOCK MIDNIGHT LIBRARY

beginning of operation.

3) Aesthetics 4) Suitable for high ceiling space


Standard drain-pump with 850mm lift

FLOORSENSE COOL CROWDSENSE drain


850
Image: during cooling Horizontal airflow
(with motion sensor +
30mm thickness mm
(with radiant
temperature radiant temperature sensor)
sensor) optimize In case of occupancy
both IDU air flow changes, predictive
(Cooling)
& cooling capacity adjustment of cooling Up to
to prevent floor or heating operation to 4.6m
down
overcooling prevent fluctuations of
Fully opened louvers
indoor temperature due doesn’t exceed the
Detect people
to human body heat. surface
simple design

* Air flow rate: Hi2


* 2.0-2.5 FSRE 36

37

CASSETTE

2-WAY CASSETTE COMPACT TYPE 1-WAY CASSETTE TYPE


(DC MOTOR TYPE) [RCD-FSR] (DC MOTOR TYPE) [RCS-FSR]

FEATURES AND BENEFITS FEATURES AND BENEFITS

1) Control air flow with individual louvers 1) 3 installation types selectable


Suitable environment can be achieved for each person

SET FREE mini HNSQ Series


Corner type (standard) Clipped ceiling (one-way) type Clipped ceiling (two-way) type
Allows for ceiling planning for Suitable for design that focuses Provides increased comfort through
lighting and interiors, suitable for on lighting and clipped ceilings, in two-direction airflow by utilizing
installation in the perimeter zone case the unit is unable to be directly the advantages of installation on a
near the window embedded in the ceiling clipped ceiling. Room temperature
distribution can be improved by both
forward airflow and downward airflow

Horizontal Blow
25°
60°
louver opens up to

CASSETTE
2) The height of the space for 3) Suitable for high ceiling space 2) Quiet operation 3) Suitable for high ceiling space
installing the unit can be Standard drain-pump with 850mm lift
Standard drain-pump with 850mm lift New design in fan inlet and fan resulted in the low
fine-tuned
* Air flow rate: Hi2 sound pressure
* 2.0-6.0 FSR
IDU cooling capacity (kW) 2.2 2.8 4.0 5.6 7.1 8.0

Sound Pressure Level (dB(A)) 27 28 31 31 32 33 drain

*Air flow rate: Lo


850
mm
drain
Easier height 850 20dB(A) 30dB(A)
mm CLOCK MIDNIGHT
Adjustment

panel
(Cooling)
Up to
(Cooling)
Up to
5.3m
down
4.6m
down

corner pocket

*Air flow rate: Hi2


*2.5-3.0 FSR
*standard corner type

38

39

CONCEALED & EXPOSED

FEATURES COMPARISON
KEY INFORMATION
WALL MOUNTED FLOOR/CEILING CEILING FLOOR
TYPE CONVERTIBLE SUSPENDED CONCEALED
TYPE TYPE TYPE

Model

RPK-FSRM RPK-HNBUSQ RPFC-FSNQ RPC-FSR RPFI-FSNQ


WALL MOUNTED TYPE WALL MOUNTED TYPE FLOOR/CEILING CONVERTIBLE TYPE
(DC MOTOR TYPE) (DC MOTOR TYPE) (AC MOTOR TYPE)
Temperature Setting Rate 0.5°C/1.0°C 1.0°C 1.0°C 0.5°C/1.0°C 1.0°C
[RPK-FSRM] [RPK-HNBUSQ] [RPFC-FSNQ]
∙ Simple installation procedure ∙ Economic choice for any type of room ∙Each unit can be floor mounted or ceiling suspended

SET FREE mini HNSQ Series


∙ Flexible discreet design suitable for any interior ∙ Display set-temperature and operation status on front cover ∙ Easy installation Indoor Fan Speed 4 taps 6 taps 3 taps 4 taps 3 taps
∙ Setback temperature control available, leading to better by LED ∙ Fresh air-intake design
operation. Louver Direction 7 (*3) 7 (*3) 7 (*3) 7 (*3) -
∙ GentleCool control to ensure you are not bothered by cold draft
Individual Louver Setting - - - - -

Auto Louver Setting - - - -

Dry mode Availability

Setback (Away Function) - - -


COMFORT
Cold Draft Prevention Availability (*1) (*4) -

Comfort setting Control Cool Air (GentleCool) (*2) - - -


CEILING SUSPENDED TYPE FLOOR CONCEALED TYPE Direct/Indirect louver direction in COOL - - - - -
(DC MOTOR TYPE) (AC MOTOR TYPE)
[RPC-FSR] [RPFI-FSNQ] Direct/Indirect louver direction in HEAT - - - - -
∙ Ideal for a higher ceiling ∙ When there is no ceiling void, this unit gives you a minimal,
(up to 5.6m in cooling) low visibility option as it can be installed in floor cavities and FeetWarm air flow control - - - - -
∙ Better power-saving with optional Motion Sensor walls
∙ Quiet operation level ∙ Little installation space required, with only 202/220mm depth
(as low as 28dB(A)) ∙ Suitable for installation under a window, with a 620mm height FloorSense Cool air flow control - - - - -
∙ Setback temperature control available, leading to better operation.
∙ GentleCool control to ensure you are not bothered by cold draft Power Saving with Motion Sensor (*2) - - - -
∙ ViroSense S filter as standard!
Outdoor Unit Peak cut control - - -
capacity
control (*2) moderate control - - -

CONCEALED & EXPOSED


POWER-SAVING Indoor Unit Indoor Unit Address - - -
Rotation
Control (*2) Indoor Air Temperature difference - - -

Automatic Fan Operation


COMPARISON
Quick Function (*2) - - -

IDU Category Cooling (kW) 2.2 2.8 3.6 4.0 4.3 5.0 5.6 6.3 7.1 8.0 8.4 9.0 11.2 14.0 14.2 16.0 Daylight Saving Time

WALL MOUNTED TYPE Power Consumption visualization (*2) - - -


(DC MOTOR TYPE)
MENU
[RPK-FSRM] Weekly Schedule Setting
WALL MOUNTED TYPE Power-Saving Setting (*2) - - -
CONCEALED & EXPOSED

(DC MOTOR TYPE)


[RPK-HNBUSQ] Dirty Filter Notice Availability
FLOOR / CEILING CONVERTIBLE TYPE Sensor Condition Check
(AC MOTOR TYPE)
[RPFC-FSNQ] Model Display (*2) - - - -
Check Menu
CEILING SUSPENDED TYPE MAINTENANCE Indoor/Outdoor PCB Check
(DC MOTOR TYPE)
[RPC-FSR] Alarm History Display
FLOOR CONCEALED TYPE
(AC MOTOR TYPE) Motion Sensor - - - SOR-NEP -
[RPFI-FSNQ] PC-RLH11 (*5) PC-RLH11 (*5) PC-RLH11 (*5)
Receiver Kit for wireless remote controller PC-ALHZ1 PC-ALHP1
PC-ALHZ1 PC-ALHZ1 PC-ALHZ1
DUPC-63K1
Drain-up mechanism availability - - - DUPC-71K1 -
DUPC-160K1
OPTIONAL
ACCESSORY ViroSense S filter - - - -

Strainer kit MSF-NP112A1 MSF-NP63A1 - - -

(*1) This function is utilized to prevent cold discharged air at start-up of heating operation, after defrosting operation, etc.
(*2) Advanced wired remote controller PC-ARF1 needs to be connected.
(*3) 5 steps only in the operation of Cooling or Dry.
(*4) Please consult your distributor for the availability.
(*5) Basic Receiver kit (PC-RLH11) is equipped with the unit in package as standard optional part with Wireless Remote Controller (PC-LH7QE).
40

41

CONCEALED & EXPOSED

WALL MOUNTED TYPE WALL MOUNTED TYPE


(DC MOTOR TYPE) [RPK-FSRM] (DC MOTOR TYPE) [RPK-HNBUSQ]

FEATURES AND BENEFITS FEATURES AND BENEFITS

1) Simple installation procedure 1) Meet your detailed requirement & Display


2) Flexible discreet design suitable for any interior DC fan motor help realize 6-step fan speed adjustment, more quiet and efficient.Also newly equipped
display set-temperature and operation status on front cover by LED.
3) Hotel Setback feature available, leading to better operation
4) GentleCool control to ensure you are not bothered by cold draft 2) Simple installation procedure.

SET FREE mini HNSQ Series


 efrigerant piping can be connected from the rear, base, or left of the unit, providing much greater
R
flexibility for piping and selection of installation sites.

3) Flexible design suitable for any décor.


With smooth flat covers, the units match most modern interiors. Their compact size enables them to
blend in, even in small spaces.
Compact cabinet design with 203mm depth up to 1.3HP and 230mm depth up to 2.5HP.

4) Easy maintenance.
Front flat panel keeps the unit from dust and facilitates maintenance work.
The front grille hinges open easily—no tools are needed to gain quick access to the filter.
The filter can be removed and cleaned as required.

CONCEALED & EXPOSED


42

43

CONCEALED & EXPOSED

FLOOR/CEILING CONVERTIBLE TYPE CEILING SUSPENDED TYPE


(AC MOTOR TYPE) [RPFC-FSNQ] (DC MOTOR TYPE) [RPC-FSR]

FEATURES AND BENEFITS FEATURES AND BENEFITS

1) Adapts to both floor and ceiling 1) Wide Detection area of motion sensor (SOR-NEP)
⟦CEILING USE⟧ ⟦FLOOR USE⟧ (Optional part) to achieve better energy-saving
Supplies air to a wide area. High ceiling use capability. Smaller footprint: Only 230mm in depth. Suitable for installation
beneath a window thanks to the 680mm height.

SET FREE mini HNSQ Series


7m

Ceiling
Height
2.7m

1.8m 7m

Ceiling Type

2) Auto louver ceiling


Floor Type
Auto louver

CONCEALED & EXPOSED


2) New air-intake design
Equipped with air-intakes, the unit connects with ventilations
off down horizontal
such as a Total Heat Exchanger using a duct, providing better Floor 8m
interior air quality.

3) New design in fan inlet and fan resulted 4) Suitable for high ceiling space
in the low sound pressure

Cooling capacity (kW) 4.0 8.0 11.2 14.0 IDU Capacity HP(Class) 1.5-3.0 4.0-6.0

Sound Pressure Level (dB(A)) 28 29 32 35 Height (m) 3.5 4.3

*Air flow rate: Lo * air flow volume: high


20dB(A) 30dB(A)
CLOCK MIDNIGHT

(Option)
drain
600
mm

(Cooling)
Up to
5.6m
down

44
* Air flow rate: Hi2
* 4.0-6.0 FSR 45
– –
CONCEALED & EXPOSED GENERAL DATA & ACCESSORIES

FLOOR CONCEALED TYPE HIGH ESP TYPE (HIGH EXTERNAL STATIC PRESSURE TYPE)
(AC MOTOR TYPE) [RPIH-HNAUN1Q]
(AC MOTOR TYPE) [RPFI-FSNQ]
Model RPIH-3.0HNAUN1Q RPIH-3.3HNAUN1Q RPIH-4.0HNAUN1Q RPIH-5.0HNAUN1Q RPIH-6.0HNAUN1Q

FEATURES AND BENEFITS Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz]


Cooling kW 8.4 9.0 11.2 14.2 16.0
Nominal Capacity
Heating kW 9.6 10.0 13.0 16.3 18.0
Blends unobtrusively with any interior Sound Pressure
(Hi/Me/Lo) dB(A) 42/39/34 42/39/34 43/39/34 44/41/37 48/42/37
Level
décor: only the suction and discharge grilles
Outer Dimension H×W×D mm 300×1,175×800 300×1,175×800 300×1,175×800 300×1,475×800 300×1,475×800
are visible.
Its low height (only 620mm) enables the Net Weight kg 45 45 45 53 54
Refrigerant R410A R410A R410A R410A R410A
unit to fit perfectly beneath a window.

SET FREE mini HNSQ Series


Indoor Fan
(Hi/Me/Lo) m3/min 30/28/23 30/28/23 30/28/23 35.5/32/27 41/33/26
Requires little installation space thanks to Air Flow Rate
Air Outlet External Static Pressure (*3) Pa 120(90) 120(90) 120(90) 120(90) 120(90)
its slim 202mm depth.
Connections Flare-Nut Connection (with Flare Nuts)
Cavity that Refrigerant Piping Liquid Line mm Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
Diameter Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
conceals
Condensate Drain VP25 VP25 VP25 VP25 VP25
the unit Approximate Packing Volume m3 0.40 0.40 0.40 0.49 0.49

Basic PC-RLH11
Receiver Kit
Advanced PC-ALHZ1

620mm
Condensate Drain Pump Kit DUPI-361Q
3.0-4.0 (HP class) KW-PP9Q
Air filter
5.0-6.0 (HP class) KW-PP10Q
AQtiv-Ion Kit JK-LZAQ
900-1,170mm
Air Inlet NOTES:
1. The cooling capacities above show the maximum capacities when the outdoor 2. The sound pressure level is based on following conditions. 1.4 metre Beneath the unit.
and indoor temperature are under the following conditions. With Discharge Duct (2.0 metre) and Return Duct (1.0 metre).
Voltage of the power source for the indoor fan motor is 220V.
Cooling Operation Conditions Heating Operation Conditions (In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).)
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
202mm The above data was measured in an anechoic chamber so that reflected sound should be taken

CONCEALED & EXPOSED/GENERAL DATA & ACCESSORIES


19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB into consideration in the field.
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length:7.5 metre Piping Length:7.5 metre 3. The data for external pressure (*3) indicates "Standard Pressure Setting values when a filter is
Piping Lift:0 metre Piping Lift:0 metre not used.

MEDIUM ESP TYPE (MEDIUM EXTERNAL STATIC PRESSURE TYPE)


(AC MOTOR TYPE) [RPIM-HNAUN1Q]
RPIM- RPIM- RPIM- RPIM- RPIM- RPIM- RPIM- RPIM-
Model 0.8HNAUN1Q 1.0HNAUN1Q 1.3HNAUN1Q 1.5HNAUN1Q 1.8HNAUN1Q 2.0HNAUN1Q 2.3HNAUN1Q 2.5HNAUN1Q
Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz]
Cooling kW 2.2 2.8 3.6 4.3 5.0 5.6 6.3 7.1
Nominal Capacity
Heating kW 2.8 3.3 4.2 4.9 5.6 6.5 7.5 8.5
Sound Pressure
(Hi/Me/Lo) dB(A) 32/27/24 32/27/24 35/33/28 35/33/28 35.5/33/28 35.5/33/28 39/34/26 39/34/26
Level
270×725 270×725 270×725 270×725 270×975 270×975 270×975 270×975
Outer Dimension (H×W×D) mm
×720 ×720 ×720 ×720 ×720 ×720 ×720 ×720
Net Weight kg 24 24 25 25 31 31 32 32
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A
Indoor Fan
(Hi/Me/Lo) m3/min 10/8/7 10/8/7 12/11/9 12/11/9 16/14/11.5 16/14/11.5 20/16/11 20/16/11
Air Flow Rate
External Static Pressure (*3) Pa 50(80) 50(80) 50(80) 50(80) 50(80) 50(80) 50(80) 50(80)
Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52
Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Volume m3 0.22 0.22 0.22 0.22 0.28 0.28 0.28 0.28

Basic PC-RLH11
Receiver Kit
Advanced PC-ALHZ1
Condensate
0.8-2.5 (HP class) DUPI-131Q
Drain Pump Kit
0.8-1.5 (HP class) KW-PP7Q
Air filter
1.8-2.5 (HP class) KW-PP8Q
AQtiv-Ion Kit JK-LZAQ

NOTES:
1. The cooling capacities above show the maximum capacities when the outdoor 2. The sound pressure level is based on following conditions. 1.4 metre Beneath the unit.
and indoor temperature are under the following conditions. With Discharge Duct (2.0 metre) and Return Duct (1.0 metre).
Voltage of the power source for the indoor fan motor is 220V.
Cooling Operation Conditions Heating Operation Conditions (In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).)
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB The above data was measured in an anechoic chamber so that reflected sound should be taken
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB into consideration in the field.
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length:7.5 metre Piping Length:7.5 metre 3. The data for external pressure (*3) indicates "Standard Pressure Setting values when a filter is 46
Piping Lift:0 metre Piping Lift:0 metre not used.
47

GENERAL DATA & ACCESSORIES

LOW ESP TYPE (LOW EXTERNAL STATIC PRESSURE TYPE) COMPACT TYPE
(AC MOTOR TYPE) [RPIL-HNAUN1Q] (DC MOTOR TYPE) [RPIZ-HNDTS1Q]

Model RPIL-0.8HNAUN1Q RPIL-1.0HNAUN1Q RPIL-1.3HNAUN1Q RPIL-1.5HNAUN1Q RPIL-1.8HNAUN1Q RPIL-2.0HNAUN1Q RPIL-2.3HNAUN1Q Model RPIZ- RPIZ-
0.8HNDTS1Q 1.0HNDTS1Q
RPIZ-
1.3HNDTS1Q
RPIZ-
1.5HNDTS1Q
RPIZ-
1.8HNDTS1Q
RPIZ-
2.0HNDTS1Q
RPIZ-
2.3HNDTS1Q
RPIZ-
2.5HNDTS1Q
Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz]
Cooling kW 2.2 2.8 3.6 4.3 5.0 5.6 6.3 Cooling kW 2.2 2.8 3.6 4.0 5.0 5.6 6.3 7.1
Nominal Capacity Nominal Capacity
Heating kW 2.8 3.3 4.2 4.9 5.6 6.5 7.5 Heating kW 2.5 3.2 4.0 4.5 5.6 6.3 7.1 8.0
Sound Pressure Sound Pressure 33/31/28/ 33/31/28/ 33/31/28/ 31/30/28/ 36/33.5/31/ 36/33.5/31/ 37/36/33/ 37/36/33/
(Hi/Me/Lo) dB(A) 28/25/22 28/25/22 34/32/30 34/32/30 34/32/29 34/32/29 36.5/30.5/25 (6 taps) dB(A)
Level Level 25/23.5/22.5 25/23.5/22.5 25/23.5/22.5 25/22/20 28/24.5/22.5 28/24.5/22.5 30/28/25 30/28/25
Outer Dimension (H×W×D) mm 270×725×720 270×725×720 270×725×720 270×725×720 270×975×720 270×975×720 270×975×720 Outer Dimension H×W×D mm 192×700×447 192×700×447 192×700×447 192×910×447 192×1,180×447 192×1,180×447 192×1,180×447 192×1,180×447
Net Weight kg 24 24 25 25 31 31 32 Net Weight kg 17 17 17 20 24 24 24 24
Refrigerant R410A R410A R410A R410A R410A R410A R410A Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A
Indoor Fan Indoor Fan 8.5/8/7/ 8.5/8/7/ 8.5/8/7/ 10/9/8/ 14.5/13.2/11.8/ 14.5/13.2/11.8/ 16.5/15/13/ 16.5/15/13/
(Hi/Me/Lo) m3/min 9/8/7 9/8/7 13/11/9 13/11/9 15/14/12 15/14/12 21/14/11 (6 taps) m3/min

SET FREE mini HNSQ Series


Air Flow Rate Air Flow Rate 6/5.5/5 6/5.5/5 6/5.5/5 7.5/6.5/6 10.5/9.2/8.0 10.5/9.2/8.0 12/10/9 12/10/9
External Static Pressure (*3) Pa 30 30 30 30 30 30 30 External Static Pressure (*3) Pa 10(0-10-30) 10(0-10-30) 10(0-10-30) 10(0-10-30) 10(0-10-50) 10(0-10-50) 10(0-10-50) 10(0-10-50)
Connections Flare-Nut Connection (with Flare Nuts) Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52
Refrigerant Piping Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52
Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Diameter Gas Line mm Φ12.70 Φ12.70 Φ12.70 Φ12.70 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Volume m3 0.22 0.22 0.22 0.22 0.28 0.28 0.28 Approximate Packing Volume m3 0.142 0.142 0.142 0.15 0.18 0.18 0.18 0.18

Model RPIL-2.5HNAUN1Q RPIL-3.0HNAUN1Q RPIL-3.3HNAUN1Q RPIL-4.0HNAUN1Q RPIL-5.0HNAUN1Q RPIL-6.0HNAUN1Q Receiver Kit


Basic PC-RLH11
Advanced PC-ALHZ1
Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz]
Condensate Drain Pump Kit - (included as standard equipment)
Cooling kW 7.1 8.4 9.0 11.2 14.2 16.0
Nominal Capacity 0.8-1.3 (HP Class) KW-PP12Q
Heating kW 8.5 9.6 10.0 13.0 16.3 18.0
Air filter 1.5 (HP Class) KW-PP5Q
Sound Pressure
(Hi/Me/Lo) dB(A) 36.5/30.5/25 38/30/24 38/30/24 38/35/31 44/39/35 46/41/35 1.8-2.5 (HP Class) KW-PP6Q
Level
Outer Dimension (H×W×D) mm 270×975×720 300×1,175×800 300×1,175×800 300×1,175×800 300×1,475×800 300×1,475×800 AQtiv-Ion Kit JK-LZAQ
Net Weight kg 32 45 45 45 53 54 NOTES:
Refrigerant R410A R410A R410A R410A R410A R410A 1. T
 he cooling capacities above show the maximum capacities when the outdoor 2. The sound pressure level is based on following conditions. 1.4 metre Beneath the unit.
and indoor temperature are under the following conditions. With Discharge Duct (2.0 metre) and Return Duct (1.0 metre).
Indoor Fan
(Hi/Me/Lo) m3/min 21/14/11 29/25/21 29/25/21 29/25/21 36/31/26 42/34/26 Voltage of the power source for the indoor fan motor is 220V.
Air Flow Rate Cooling Operation Conditions Heating Operation Conditions (In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).)
External Static Pressure (*3) Pa 30 60 60 60 60 60 Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB The above data was measured in an anechoic chamber so that reflected sound should be taken
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB into consideration in the field.
Connections Flare-Nut Connection (with Flare Nuts) Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB

CONCEALED & EXPOSED/GENERAL DATA


Piping Length:7.5 metre Piping Length:7.5 metre 3. The data for external pressure (*3) indicates "Standard Pressure Setting values when a filter is
Refrigerant Piping Liquid Line mm Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
not used.
Piping Lift:0 metre Piping Lift:0 metre
Diameter Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
4. When the model of RAS-7.0~12HNBRMQ outdoor unit is connected to the compact ducted type
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 indoor units (RPIZ), if only one indoor unit is in cooling operation,and the capacity is less than
Approximate Packing Volume m 3
0.28 0.40 0.40 0.40 0.49 0.49 2.8kW, the minimum outdoor temperature is 5.0°C DB.

Basic PC-RLH11 0.8-1.5 (HP class) KW-PP7Q


Receiver Kit
Advanced PC-ALHZ1
Air filter
1.8-2.5 (HP class) KW-PP8Q COMPACT TYPE
Condensate 0.8-2.5 (HP class) DUPI-131Q 3.0-4.0 (HP class) KW-PP9Q
Drain Pump Kit 3.0-6.0 (HP class) DUPI-361Q 5.0-6.0 (HP class) KW-PP10Q
(AC MOTOR TYPE) [RPIZ-HNATN1Q]
AQtiv-Ion Kit JK-LZAQ
RPIZ- RPIZ- RPIZ- RPIZ- RPIZ- RPIZ- RPIZ- RPIZ-
NOTE:
Model 0.8HNATN1Q 1.0HNATN1Q 1.3HNATN1Q 1.5HNATN1Q 1.8HNATN1Q 2.0HNATN1Q 2.3HNATN1Q 2.5HNATN1Q
1. The cooling capacities above show the maximum capacities when the outdoor and indoor temperature are under 2. The
 sound pressure level is based on following conditions. 1.4 metre Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz]
the following conditions. Beneath the unit. Cooling kW 2.2 2.8 3.6 4.0 5.0 5.6 6.3 7.1
Cooling Operation Conditions Heating Operation Conditions With Discharge Duct (2.0 metre) and Return Duct (1.0 metre). Nominal Capacity
Voltage of the power source for the indoor fan motor is 220V. Heating kW 2.5 3.2 4.0 4.5 5.6 6.3 7.1 8.0
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB (In case of the power source of 240V, the sound pressure level increases Sound Pressure
(Hi/Me/Lo) dB(A) 30/23/20 30/23/20 34/25/22 32.5/26/23 34/26/25 34/26/25 37/29/27 37/29/27
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB by about 1~2dB(A).) Level
Piping Length: 7.5 metre Piping Length: 7.5 metre The above data was measured in an anechoic chamber so that reflected Outer Dimension H×W×D mm 192×700×447 192×700×447 192×700×447 192×910×447 192×1,180×447 192×1,180×447 192×1,180×447 192×1,180×447
Piping Lift: 0 metre Piping Lift: 0 metre sound should be taken into consideration in the field.
Net Weight kg 17 17 17 21 27 27 28 28
3. T
 he data for external pressure (*3) indicates "Standard Pressure Setting
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A
values when a filter is not used.
Indoor Fan
(Hi/Me/Lo) m3/min 9.5/6.5/5.5 9.5/6.5/5.5 9.5/6.5/5.5 10/7/6 15/10/9 15/10/9 17/10/9 17/10/9
Air Flow Rate
External Static Pressure (*3) Pa 10(30) 10(30) 10(30) 10(30) 10(30) 10(30) 10(30) 10(30)
Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52
Diameter Gas Line mm Φ12.70 Φ12.70 Φ12.70 Φ12.70 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Volume m3 0.142 0.142 0.142 0.15 0.18 0.18 0.18 0.18

Basic PC-RLH11
Receiver Kit
Advanced PC-ALHZ1
Condensate Drain Pump Kit - (included as standard equipment)
0.8-1.3 (HP Class) KW-PP12Q
Air filter 1.5 (HP Class) KW-PP5Q
1.8-2.5 (HP Class) KW-PP6Q
AQtiv-Ion Kit JK-LZAQ

NOTES:
1. The cooling capacities above show the maximum capacities when the outdoor 2. The sound pressure level is based on following conditions. 1.4 metre Beneath the unit.
and indoor temperature are under the following conditions. With Discharge Duct (2.0 metre) and Return Duct (1.0 metre).
Voltage of the power source for the indoor fan motor is 220V.
Cooling Operation Conditions Heating Operation Conditions (In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).)
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB The above data was measured in an anechoic chamber so that reflected sound should be taken 48
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB into consideration in the field.
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length:7.5 metre Piping Length:7.5 metre 3. The data for external pressure (*3) indicates "Standard Pressure Setting values when a filter is 49
Piping Lift:0 metre Piping Lift:0 metre not used.
4. When the model of RAS-7.0~12HNBRMQ outdoor unit is connected to the compact ducted type
indoor units (RPIZ), if only one indoor unit is in cooling operation,and the capacity is less than
2.8kW, the minimum outdoor temperature is 5.0°C DB.

GENERAL DATA & ACCESSORIES

4-WAY CASSETTE TYPE Silent-IconicTM


(DC MOTOR TYPE) [RCI-FSRP] Neutral White Beige Gray Black for 4-WAY CASSETTE (RCI-FSRP)
Model RCI-1.0FSRP RCI-1.5FSRP RCI-2.0FSRP RCI-2.5FSRP RCI-3.0FSRP RCI-4.0FSRP RCI-5.0FSRP RCI-6.0FSRP

Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz]


Nominal Cooling kW 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0
Capacity Heating kW 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0
Sound Pressure
(Hi2/Hi/Me/Lo) dB(A) 33/30/28/27 35/31/30/27 37/32/30/27 42/36/32/28 42/36/32/28 48/43/39/33 48/45/40/35 48/46/41/37
Level
Outer Dimension (H×W×D) mm 248×840×840 248×840×840 248×840×840 248×840×840 298×840×840 298×840×840 298×840×840 298×840×840
Net Weight kg 20 21 21 22 26 26 26 26
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A
Indoor Fan
(Hi2/Hi/Me/Lo) m3/min 15/13/11/9 21/17/14/11 22/17/14/11 27/23/18/14 27/23/18/14 37/31/24/20 37/33/26/21 37/35/28/22

SET FREE mini HNSQ Series


Air Flow Rate
Connections Flare-Nut Connection (with flare Nuts)
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
Model P-GP160NAP P-GP160NAPU P-GP160KAP
Refrigerant
Piping Diameter Gas Line mm Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 satandard/option Design Panel Standard Design Panel with an Elevation Grille Design Panel Standard
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 color Natural White Natural White Black
Approximate Packing Volume m3 0.21 0.21 0.21 0.21 0.25 0.25 0.25 0.25

Twin-Sense panel P-AP160NAE2 T-Pipe Connection Kit TKCI-160K


Decoration panel Standard (without 1.0-2.5 (HP Class) F-71L-D1
sensor) P-AP160NA3
Normal Air Filter 3.0-6.0 (HP Class) F-160L-D1
Receiver kit Advanced PC-ALH3
Filter Box B-160H3
Condensate Drain Pump Kit - (Standard)
ViroSense Z2 filter F-160L-ZV
Duct Adapter PD-75A
ViroSense S filter - (Standard)
Fresh Air Intake Kit OACI-160K3
3-Way Outlet Parts Set PI-160LS2

NOTES:
1. The
 cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre

CONCEALED & EXPOSED/GENERAL DATA


2. The
 sound pressure level is based on following conditions. 1.5 metre Beneath the unit.
The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

4-WAY CASSETTE TYPE 4-WAY CASSETTE COMPACT TYPE


(DC MOTOR TYPE) [RCI-FSKDN1Q] (DC MOTOR TYPE) [RCIM-FSRE]
RCI- RCI- RCI- RCI- RCI- RCI- RCI- RCI- RCI-
Model 1.0FSKDN1Q 1.5FSKDN1Q 2.0FSKDN1Q 2.3FSKDN1Q 2.5FSKDN1Q 3.0FSKDN1Q 4.0FSKDN1Q 5.0FSKDN1Q 6.0FSKDN1Q Model RCIM-0.8FSRE RCIM-1.0FSRE RCIM-1.5FSRE RCIM-2.0FSRE RCIM-2.5FSRE

Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz] Indoor Unit Power Supply AC 1Φ, [230V/50Hz] [220-240V/50Hz] [220V/60Hz]
Nominal Cooling kW 2.8 4.0 5.6 6.3 7.1 8.0 11.2 14.0 16.0 Nominal Cooling kW 2.2 2.8 4.0 5.6 7.1
Capacity Heating kW 3.2 4.8 6.3 7.1 8.5 9.0 12.5 16.0 18.0 Capacity Heating kW 2.5 3.2 4.8 6.3 8.5
Sound Pressure Sound Pressure
(Hi2/Hi/Me/Lo) dB(A) 33/30/28/27 35/31/30/27 37/32/30/27 42/36/32/28 42/36/32/28 42/36/32/28 48/43/39/33 48/45/40/35 48/46/41/37 (Hi2/Hi/Me/Lo) dB(A) 36/33/29/24.5 38/34/30/24.5 41/37/33/27.5 45/39/35/31 47/43/39/35
Level Level
Outer Dimension (H×W×D) mm 238×840×840 238×840×840 238×840×840 238x840x840 238×840×840 288×840×840 288×840×840 288×840×840 288×840×840 Outer Dimension (H×W×D) mm 285×570×570 285×570×570 285×570×570 285×570×570 285×570×570
Net Weight kg 20 21 21 22 22 26 26 26 26 Net Weight kg 16 16 16 17 17
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A Refrigerant R410A R410A R410A R410A R410A
Indoor Fan Indoor Fan
(Hi2/Hi/Me/Lo) m3/min 15/13/11/9 21/17/14/11 22/17/14/11 27/23/18/14 27/23/18/14 27/23/18/14 37/31/24/20 37/33/26/21 37/35/28/22 (Hi2/Hi/Me/Lo) m3/min 11/9.5/8/6 12/10/8.5/6 13/11/9.5/7 15/12/10/8 16/14/12/10
Air Flow Rate Air Flow Rate
Connections Flare-Nut Connection (with flare Nuts) Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52
Piping Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Piping Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 Condensate Drain VP25 VP25 VP25 VP25 VP25
Approximate Packing Volume m3 0.21 0.21 0.21 0.21 0.21 0.25 0.25 0.25 0.25 Approximate Packing Volume m3 0.13 0.13 0.13 0.13 0.13

- (Standard) Condensate Drain Pump Kit - (Standard) Decoration panel P-AP56NAM Motion Sensor SOR-NEC
Decoration Panel
Twin-Sense panel P-AP160NAE2 + OPT-EZJ01 Duct Adapter PD-75A Decoration panel Condensate Drain Pump Kit - (Standard)
Advanced P-AP56NAMR
Basic HR4A10NEWQ ViroSense Z2 filter F-160L-ZV with Receiver kit Duct Adapter PD-75C
Receiver Kit Receiver kit Advanced PC-ALHC1
Advanced PC-ALH3 ViroSense S filter - (Standard)

NOTE: NOTES:
1. T
 he cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions. 1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB (80.0ᵒF DB) Indoor Air Inlet Temperature: 20.0ᵒC DB (68.0ᵒF DB) Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7.0ᵒC DB (45.0ᵒF DB) 19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB (95.0ᵒF DB) 6.0ᵒC WB (43.0ᵒF WB) Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre Piping Length:7.5 metre Piping Length:7.5 metre 50
Piping Lift: 0 metre Piping Lift: 0 metre Piping Lift:0 metre Piping Lift:0 metre
2. The sound pressure level is based on following conditions. 1.5 metre Beneath the unit. 51
2. The
 sound pressure level is based on following conditions. 1.5 metre Beneath the unit.
T
 he data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

GENERAL DATA & ACCESSORIES

2-WAY CASSETTE TYPE WALL MOUNTED TYPE


(DC MOTOR TYPE) [RCD-FSR] (DC MOTOR TYPE) [RPK-FSRM]
Type Expansion Valve built-in type
Model RCD-0.8FSR RCD-1.0FSR RCD-1.5FSR RCD-2.0FSR RCD-2.5FSR RCD-3.0FSR RCD-4.0FSR RCD-5.0FSR RCD-6.0FSR

Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz] Model RPK-2.5FSRM RPK-3.0FSRM RPK-4.0FSRM

Nominal Cooling kW 2.2 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0 Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz]
Capacity Heating kW 2.5 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0 Cooling kW 7.1 8.0 11.2
Nominal Capacity
Sound Pressure Heating kW 8.5 9.0 12.5
(Hi2/Hi/Me/Lo) dB(A) 30/29/28/27 31/29/28/27 37/34/31/30 39/36/33/30 42/39/36/33 45/42/38/33 43/40/37/34 47/44/41/35 48/45/42/39
Level Sound Pressure
(Hi2/Hi/Me/Lo) dB(A) 45/42/38/35 47/44/40/35 51/48/44/39
Outer Dimension (H×W×D) mm 298×860×630 298×860×630 298×860×630 298×860×630 298×860×630 298×860×630 298×1,420×630 298×1,420×630 298×1,420×630 Level
Net Weight kg 23 23 25 25 25 25 39 39 39 Color White
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A Outer Dimension (H×W×D) mm 300×1,100×260 300×1,100×260 300×1,100×260
Indoor Fan 16.5/14.5/ 18.5/16.5/ 21/18.5/ 37/32.5/ Net Weight kg 15 15 15
(Hi2/Hi/Me/Lo) m3/min 10/9/7.5/6.5 11/9.5/8.5/7 15/13/11.5/10 30/26.5/23/20 35/31/27/21

SET FREE mini HNSQ Series


Air Flow Rate 12.5/10.5 14.5/12.5 16/12.5 28.5/24 Refrigerant R410A R410A R410A
Connections Flare-Nut Connection (with Flare Nuts) Indoor Fan
(Hi2/Hi/Me/Lo) m3/min 18.5/16.5/14/12 20/17.5/15.5/12.5 23/20/17.5/14.5
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Air Flow Rate
Piping Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Motor 38 38 38
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 Connections Flare-Nut Connection (with Flare Nuts)
Approximate Packing Volume m3 0.24 0.24 0.24 0.24 0.24 0.24 0.36 0.36 0.36 Refrigerant Piping Liquid Line mm Φ9.52 Φ9.52 Φ9.52
Diameter Gas Line mm Φ15.88 Φ15.88 Φ15.88
0.8-3.0 (HP Class) P-AP90DNA 0.8-3.0 (HP Class) F-90MD-K1 Condensate Drain VP16 VP16 VP16
Decoration panel
4.0-6.0 (HP Class) P-AP160DNA 4.0-6.0 (HP Class) F-160MD-K1 Approximate Packing Volume m3 0.14 0.14 0.14
Normal Air Filter
Receiver kit Advanced PC-ALHD1 Filter 0.8-3.0 (HP Class) B-90HD Accessory included Wall Mounting Bracket
Motion Sensor SOR-NED Box 4.0-6.0 (HP Class) B-160HD
Condensate Drain Pump Kit - (Standard) ViroSense S filter - (Standard) Receiver kit Advanced PC-ALHZ1
Duct Adapter PD-150D Strainer kit 2.5-4.0 (HP Class) MSF-NP112A1

NOTES: NOTES:
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor
STRAINER KIT
1. T
 he cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions. Strainer Kit Refrigerant Pipe
Cooling Operation Conditions Heating Operation Conditions temperature are under the following conditions.
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB Cooling Operation Conditions Heating Operation Conditions
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB 19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Piping Length:7.5 metre Piping Length:7.5 metre Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
solid foreign filter
Piping Lift:0 metre Piping Lift:0 metre Piping Length: 7.5 metre Piping Length: 7.5 metre
substances
Piping Lift: 0 metre Piping Lift: 0 metre
2. The
 sound pressure level is based on following conditions. 1.5 metre Beneath the unit.
2. The sound pressure level is based on following conditions. A strainer kit ensures that solid foreign substances, like small particles

CONCEALED & EXPOSED/GENERAL DATA


The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
1.0 metre Beneath the Unit. of metal, are caught before they enter the electric expansion valves of a
1.0 metre from Discharge Grille. wall-mounted indoor unit. Without the strainer kit’s filter, these particles
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. may prevent the valves from being fully sealed, creating a risk of explosive
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure. condensation when the unit becomes active.

1-WAY CASSETTE TYPE WALL MOUNTED TYPE


(DC MOTOR TYPE) [RCS-FSR] (DC MOTOR TYPE) [RPK-HNBUSQ]
RPK- RPK- RPK- RPK- RPK- RPK- RPK- RPK-
Model RCS-0.8FSR RCS-1.0FSR RCS-1.5FSR RCS-2.0FSR RCS-2.5FSR RCS-3.0FSR Model 0.8HNBUSQ 1.0HNBUSQ 1.3HNBUSQ 1.5HNBUSQ 1.8HNBUSQ 2.0HNBUSQ 2.3HNBUSQ 2.5HNBUSQ
Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] [230V/50Hz] [220V/60Hz] Indoor Unit Power Supply AC 1φ,220~240V/50Hz, ,220V/60Hz
Nominal Cooling kW 2.2 2.8 4.0 5.6 7.1 8.0 Cooling kW 2.2 2.8 3.6 4.0 5.0 5.6 6.3 7.1
Capacity Nominal Capacity
Heating kW 2.5 3.2 4.8 6.3 8.5 9.0 Heating kW 2.5 3.3 4.0 4.5 5.6 6.3 7.1 8.0
Sound Pressure Sound Pressure 36/35/33/ 36/35/33/ 38/35/33/ 38/37/36/ 44/42/41/ 40/38/36/ 41/40/38/ 45/42/41/
(Hi2/Hi/Me/Lo) dB(A) 34/32/29/27 36/34/31/28 40/37/33/31 42/38/35/31 43/39/36/32 43/40/37/33 (Hi/Me/Lo) dB(A)
Level Level 32/30/28 32/30/28 32/30/28 32/31/29 38/31/29 35/33/31 35/33/31 38/35/31
Outer Dimension (H×W×D) mm 235×900×710 235×900×710 235×900×710 235×900×710 235×1,210×710 235×1,210×710 Color White
Net Weight kg 25 25 26 26 33 33 Outer Dimension (H×W×D) mm 270×815×203 270×815×203 270×815×203 315×915×230 315×915×230 315×1085×230 315×1085×230 315×1085×230
Refrigerant R410A R410A R410A R410A R410A R410A Net Weight kg 9.0 9.0 9.0 12.5 12.5 14.0 14.0 14.0
Indoor Fan Refrigerant R410A R410A R410A R410A R410A R410A R410A
(Hi2/Hi/Me/Lo) m3/min 8.5/7.5/6.5/6 9.5/8.5/7.5/6.5 13/11.5/10/8.5 14.5/13/11/9.5 18.5/16.5/14.5/12.5 20/17.5/15.5/13
Air Flow Rate Indoor Fan 9.8/9.2/8.7/ 9.8/9.2/8.7/ 10.3/9.2/8.7/ 11.5/11.0/10.3/ 14.3/13.5/12.8/ 16.2/15.0/14.2/ 17.0/16.2/15.0/ 20.0/18.0/17.0/
Connections Flare-Nut Connection (with Flare Nuts) (Hi/Me/Lo) m3/min
Air Flow Rate 8.2/7.5/7.0 8.2/7.5/7.0 8.2/7.5/7.0 9.0/8.7/8.0 11.5/9.0/8.0 13.3/12.2/11.5 13.3/12.2/11.5 15.0/13.3/11.7
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Connections Flare-Nut Connection (with Flare Nuts)
Piping Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Refrigerant Piping Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.53 Φ9.53 Φ9.53
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 Diameter Gas Line mm Φ9.53 Φ9.53 Φ9.53 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88
3
Approximate Packing Volume m 0.25 0.25 0.25 0.25 0.32 0.32 Condensate Drain VP16 VP16 VP16 VP16 VP16 VP16 VP16 VP16
Approximate Packing Volume m3 0.11 0.11 0.11 0.15 0.15 0.17 0.17 0.17
0.8-1.0 (HP Class) P-AP36CNA Duct Adapter PD-100
Basic PC-RLH11
Decoration panel 1.5-2.0 (HP Class) P-AP56CNA Grille for 0.8-2.0 (HP Class) DG-56SW1 Receiver kit
Advanced PC-ALHZ1
2.5-3.0 (HP Class) P-AP80CNA Front Discharge 2.5-3.0 (HP Class) DG-80SW1
Strainer kit MSF-NP63A1
Receiver kit Advanced PC-ALHS1 0.8-2.0 (HP Class) PIS-56LS
Air Outlet Shutter Plate NOTES:
Motion Sensor SOR-NES 2.5-3.0 (HP Class) PIS-80LS
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Condensate Drain Pump Kit - (Standard) ViroSense S filter - (Standard)
Cooling Operation Conditions Heating Operation Conditions
NOTES: Indoor Air Inlet Temperature: 27.0ᵒC DB (80.0ᵒF DB) Indoor Air Inlet Temperature: 20.0ᵒC DB (68.0ᵒF DB)
1. T
 he cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions. 19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7.0ᵒC DB (45.0ᵒF DB)
Cooling Operation Conditions Heating Operation Conditions Outdoor Air Inlet Temperature: 35.0ᵒC DB (95.0ᵒF DB) 6.0ᵒC WB (43.0ᵒF WB)
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB Piping Length:7.5 metre Piping Length:7.5 metre
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB Piping Lift:0 metre Piping Lift:0 metre
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB 2. The sound pressure level is based on following conditions. 52
Piping Length:7.5 metre Piping Length:7.5 metre 1.0 metre Beneath the unit.
Piping Lift:0 metre Piping Lift:0 metre 1.0 metre from Discharge grille. 53
2. The
 sound pressure level is based on following conditions. 1.5 metre Beneath the unit. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure. .

GENERAL DATA & ACCESSORIES

FLOOR/CEILING CONVERTIBLE TYPE FLOOR CONCEALED TYPE


(AC MOTOR TYPE) [RPFC-FSNQ] (AC MOTOR TYPE) [RPFI-FSNQ]

Model RPFC-1.8FSNQ RPFC-2.0FSNQ RPFC-2.3FSNQ RPFC-2.5FSNQ RPFC-3.0FSNQ RPFC-3.3FSNQ RPFC-4.0FSNQ RPFC-5.0FSNQ Model RPFI-1.0FSNQ RPFI-1.5FSNQ RPFI-2.0FSNQ RPFI-2.5FSNQ

Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz] Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz]
Nominal Cooling kW 5.0 5.6 6.3 7.1 8.4 9.0 11.2 14.2 Nominal Cooling kW 2.8 4.3 5.6 7.1
Capacity Heating kW 5.6 6.5 7.5 8.5 9.6 10.0 13.0 16.3 Capacity Heating kW 3.3 4.9 6.5 8.5
Sound Pressure Ceiling Mode dB(A) 39/35/30 39/35/30 45/41/37 45/41/37 43/39/34 45/40/36 51/46/40 50/46/42 Sound Pressure
(Hi/Me/Lo) dB(A) 37/34/31 40/38/35 42/38/36 45/43/40
Level Floor Mode dB(A) 43/38/35 43/38/35 48/44/40 48/44/40 46/41/37 48/43/39 54/49/43 55/50/46 Level
Outer Dimension (H×W×D) mm 230×990×680 230×990×680 230×990×680 230×990×680 230×1,285×680 230×1,285×680 230×1,285×680 230×1,580×680 Outer Dimension (H×W×D) mm 620×900×202 620×900×202 620×1,170×202 620×1,170×202
Net Weight kg 31 31 32 32 39 40 41 47 Net Weight kg 25 26 34 34
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A Refrigerant R410A R410A R410A R410A
Indoor Fan Indoor Fan

SET FREE mini HNSQ Series


(Hi/Me/Lo) m3/h 780/660/540 780/660/540 966/840/678 966/840/678 1,092/912/732 1,164/978/798 1,488/1,230/978 1,980/1,680/1,380 (Hi/Me/Lo) m3/min 8.5/7/6 12/8/7 16/12.5/10.5 16/14/11
Air Flow Rate Air Flow Rate
Connections Flare-Nut Connection (with Flare Nuts) Connections Flare-Nut Connection (with Flare Nuts)
Liquid Line mm Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ9.52
Refrigerant
Piping Diameter Gas Line Piping Gas Line mm Φ12.70 Φ12.70 Φ15.88 Φ15.88
mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 Condensate Drain VP25 VP25 VP25 VP25
Approximate Packing Volume m3 0.31 0.31 0.31 0.31 0.40 0.40 0.40 0.48 Packaging Volume m3 0.19 0.19 0.23 0.23

Basic PC-RLH11 Basic PC-RLH11


Receiver kit Receiver kit
Advanced PC-ALHZ1 Advanced PC-ALHZ1

NOTES: NOTES:
1. T
 he cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions. 1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB 19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre Piping Lift: 0 metre Piping Lift: 0 metre

2. The
 sound pressure level is based on following conditions. 2. The sound pressure level is based on following conditions. 
1.0 metre Beneath the unit. 1.0 metre from the unit.
1.0 metre from Discharge grille. 1.0 metre from floor level.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. Voltage of the power source for the indoor fan motor is 220V.
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure. The above data was measured in an anechoic chamber.

CONCEALED & EXPOSED/GENERAL DATA


CEILING SUSPENDED TYPE
(DC MOTOR TYPE) [RPC-FSR]

Model RPC-1.5FSR RPC-2.0FSR RPC-2.5FSR RPC-3.0FSR RPC-4.0FSR RPC-5.0FSR RPC-6.0FSR

Indoor Unit Power Supply AC 1Φ, [220-240V/50Hz] [220V/60Hz]


Nominal Cooling kW 4.0 5.6 7.1 8.0 11.2 14.0 16.0
Capacity Heating kW 4.8 6.3 8.5 9.0 12.5 16.0 18.0
Sound Pressure
(Hi2/Hi/Me/Lo) dB(A) 37/35/31/28 38/35/31/28 38/35/31/28 40/37/33/29 44/42/37/32 48/45/41/35 49/47/42/36
Level
Color Neutral White
Outer Dimension (H×W×D) mm 235×960×690 235×960×690 235×1,270×690 235×1,270×690 235×1,580×690 235×1,580×690 235×1,580×690
Net Weight kg 26 27 35 35 41 41 41
Refrigerant R410A R410A R410A R410A R410A R410A R410A
Indoor Fan
(Hi2/Hi/Me/Lo) m3/min 15/13/11/9 15/13/11/9 19/16.5/14/11.5 21/18.5/15.5/12.5 30/26.5/22/17 35/31/25.5/20 37/32.5/27/21
Air Flow Rate
Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
Piping Diameter Gas Line mm Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP20 VP20 VP20 VP20 VP20 VP20 VP20
Approximate Packing Volume m3 0.23 0.23 0.31 0.31 0.38 0.38 0.38

Receiver kit Advanced PC-ALHP1


Motion Sensor SOR-NEP
1.5 (HP Class) DUPC-63K1
Condensate Drain Pump
2.0 (HP Class) DUPC-71K1
Kit
2.5-6.0 (HP Class) DUPC-160K1
ViroSense S filter - (Standard)

NOTES:
1. T
 he cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27.0ᵒC DB Indoor Air Inlet Temperature: 20.0ᵒC DB
19.0ᵒC WB Outdoor Air Inlet Temperature: 7.0ᵒC DB
Outdoor Air Inlet Temperature: 35.0ᵒC DB 6.0ᵒC WB
Piping Length: 7.5 metre Piping Length: 7.5 metre
Piping Lift: 0 metre Piping Lift: 0 metre
2. The
 sound pressure level is based on following conditions. 54
1.0 metre Beneath the unit.
1.0 metre from Discharge grille.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. 55
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure.

VENTILATIONS

RENEW AIR
Today, the average person spends more than 75% of their day indoors; at home, at work, in the gym, shopping or socializing. Many of these
environments are effectively sealed and fresh air isn't easily available
Without proper ventilation, CO2 levels rise, pollutants circulate and potentially harmful bacterias build-up, impacting on the wellbeing, comfort
and productivity of occupants.
Make these spaces as healthy and comfortable as possible by providing fresh air with our premium air renewal systems for commercial buildings

OUR LINE-UP

SET FREE mini HNSQ Series


Our line-up fulfils the ventilation requirements of the desired space by drawing TOTAL HEAT EXCHANGER
in clean air from the outside and replenishing indoor spaces. It features ∙ Creates a healthy indoor environment thanks
to introducing fresh air function and ventilation
solutions that suit every type of building; You can use the ventilation technology function
∙ Remote controller for Total Heat Exchanger is
as it is or it can be incorporated into an Hitachi indoor unit via the fresh-air port. equipped in unit as standard part
Thanks to accessories like this, you can optimize the design of your system to
meet your needs.

Fan Air Flow Rate (m3/h) 150 200 210 230 300 400 500 550 650 700 800 1,000 1,080 1,250 1,500 1,680 2,000 2,100 2,500 3,000 4,000 5,000 6,000

TOTAL HEAT EXCHANGER

KPI- KPI- KPI- KPI- KPI- KPI- KPI- KPI-


Model 20H-A-GQ 30H-A-GQ 40H-A-GQ 50H-A-GQ 65H-A-GQ 80H-A-GQ 100H-A-GQ 125H-A-GQ
Unit Power Supply AC 1Φ,[ 220/50Hz]
Summer
% 64/64/70 60/60/65 61/61/66 60/60/62 65/65/69 65/65/69 65/65/69 65/65/69
(Hi/Me/Lo)
Temp. Efficiency
Winter
% 80/80/83 77/77/80 79/79/81 75/75/76 75/75/78 74/74/78 72/72/76 70/70/78
(Hi/Me/Lo)
Summer
% 69/69/76 63/63/70 64/64/69 63/63/65 57/57/60 60/60/63 58/58/63 53/53/61
Enthalpy (Hi/Me/Lo)
Efficiency Winter
% 75/75/78 70/70/75 70/70/75 69/69/71 65/65/70 70/70/72 66/66/69 63/63/72
(Hi/Me/Lo)

VENTILATIONS
Sound Pressure
(Hi/Me/Lo) dB(A) 32/30/25 36/34/28 39/37/30 40/38/31 40/38/35 40/38/34 43/42/34 42/40/37
Level
Outer
(H×W×D) mm 220×962×735 220×962×735 220×1,112×735 220×1,112×735 388×1,119×884 388×1,119×884 388×1,119×884 430×1,250×1,135
Dimension
Net Weight kg 38 40 46 52 61 69 69 95
Air Flow Rate (Hi/Me/Lo) m3/h 200/200/150 300/300/210 400/400/230 500/500/400 650/650/550 800/800/650 1,000/1,000/700 1,250/1,250/800
External Static
(Hi/Me/Lo) Pa 100/70/40 120/90/50 120/90/50 120/90/50 130/100/90 130/100/90 165/120/60 100/50/30
Pressure
Power Input (Hi/Me/Lo) W 120/110/75 165/155/120 210/200/130 330/310/230 2×(188/173/142) 2×(207/188/165) 2×(250/228/205) 2×(308/266/237)
Current (Hi/Me/Lo) A 0.6/0.5/0.4 0.8/0.7/0.6 1.0/1.0/0.7 1.6/1.5/1.1 1.72/1.58/1.31 2.04/1.93/1.73 2.35/2.09/1.92 3.03/2.45/2.18
320×250
Connection Duct Diameter mm Φ144 Φ144 Φ144 Φ194 Φ242 Φ242 Φ242
+320×250
Approximate Packing Volume m3 0.37 0.37 0.43 0.49 0.94 1.15 1.15 1.25

KPI- KPI- KPI- KPI- KPF- KPF-


Model 150H-E-GQ 200H-E-GQ 250H-E-GQ 300H-E-GQ 400H-E-GQ 500H-E-GQ
Unit Power Supply AC 3Φ, [380/50Hz]
Summer % 63 63 63 63 63 63
Temp. Efficiency
Winter % 68 72 75 75 73 73

Enthalpy Summer % 57 57 55 56 55 53
Efficiency Winter % 68 68 72 72 63 61
Sound Pressure Level dB(A) 50 51 53 54 57 58
Outer
(H×W×D) mm 536×1,500×1,300 536×1,500×1,400 640×1,700×1,500 640×1,750×1,600 1,655×1,400×850 1,730×1,700×850
Dimension
Net Weight kg 144 155 180 220 225 260
Air Flow Rate m3/h 1,500 2,000 2,500 3,000 4,000 5,000
External Static Pressure Pa 165 160 180 200 220 240
Power Input W 2×440 2×810 2×925 2×1080 2×1,470 2×1,980
Current A 2.84 3.08 4.19 5.23 5.57 7.51
400×320 400×320 500×350 500×350 400×320 500×350
Connection Duct Diameter mm
+400×320 +400×320 +500×350 +500×350 +590×320 +700×320
Approximate Packing Volume m3 1.82 1.95 2.63 2.93 3.01 3.75 56
NOTE: 57
Please confirm the model name for "wires remote controller" compatible with Total Heat Exchanger to your local distributor.
– New generation:
CONTROLLERS simple and smart!
Everyone deserves comfort, but comfort does not mean the same
to everyone. That’s why control is key. Our controllers offer best-
in-class simplicity. Using our praised central stations, building

SET FREE mini HNSQ Series


managers can instantly optimize air conditioning in targeted zones.
For occupants, our new advanced color controller provides intuitive
navigation with a premium design.
With airCloud Pro, our exclusive new-generation solution, users can
manage from one indoor unit to several systems remotely via IoT
(web/smartphone).

60 CENTRALIZED CONTROLLERS
60 Line up overview
62
64 Central Station EX
65 Central Station EZ

CONTROLLERS
65 Central Station mini

66 INDIVIDUAL CONTROLLERS
66 Line up overview
68
70 Advanced Color Wired Remote Controller
72 Eco–Compact Controller
74 Wired remote controller
75 Advanced wireless remote controller
75 Wireless remote controller
75 Receiver kit

76 ACCESSORIES

78 H-LINK: ENJOY MORE FREEDOM 58

59

CENTRALIZED CONTROLLERS
Control each indoor unit, one specific zone or even
multiple systems from one place! Small to large systems & fixed or cloud-based
CENTRAL STATION EX CENTRAL STATION EZ CENTRAL STATION MINI

HC-IoTGW PSC-A128EX3 PSC-A64GT PSC-A32MN


RC group 64 (*6) 2,560 (*1) 64 32
Group 64 (*6) 2,048 (*1) 64 32
Block Unlimited (*7) 512 (*2) 4 2/4/8/16
Total Connection capacity

SET FREE mini HNSQ Series


Area Unlimited (*7) 512 (*2) - -
Capacity
comparison Indoor unit 80 (*6) 2,560 (*1) 160 160
Outdoor unit 16 (*6) 1,024 (*1) 64 64
Building scale Small to Large Large Medium Small
Touch screen
Operation Web + Mobile Phone Touch screen Touch screen
+ Web (New!)
Operation panel size options Adaptive 7 2 3
Display Layout - - -
List options - 3 - -
All together
By layout - - -
By area - -
Operation unit By block
By group - -
By RC group - -
By indoor unit - -
Main 5 functions (*5)
Individual controller lock △ (*3)

CENTRALIZED CONTROLLERS
Control Function Filter sign reset
Outdoor unit capacity control - - △ (*4)
Outdoor unit noise control - - -
Main 5 functions (*5)
Individual controller lock
Alarm status & code
Monitor
Filter sign
Function
Air inlet temperature of indoor unit - -
(HC-IoTGW) CENTRAL STATION EX (PSC-A128EX3) Air inlet temperature of outdoor unit - -

∙ Remote access via smartphone app or web. ∙ Control capacity: max 2,560 indoor units (+15x Frostwash status - - -

∙ Unlimited number of systems, zones and users. Extension Adapter PSC-AD128EX3). Weekly -

∙ Intuitive scheduling function. ∙ With energy calculation software (PSC-AS01EXC), Setting times per day 16 16 10 10
Schedule
∙ Troubleshooting with access to error history and alerts. determine each tenant's energy usage. Function
Special day setting 5 5 - -

∙ Filter sign display to quickly overview daily ∙ Easy monitoring with simplified interface. Holiday setting - - -

maintenance needs. ∙ Best option for middle-large size buildings. Annual/Summer/Winter schedule Future Version - -

∙ Ideal for all types of applications. ∙ Remote access! Operate Central Station EX from your Alarm history (records number) Unlimited 10,000 100 100

laptop PC or touch-panel PC. External in/output history - 1,000 - -


Energy Estimation (*8)
Other function Management report visualization(*11)
- Future
Download from Web
Data output by external media SD card, USB flash device - -
- Future
CENTRAL STATION EZ (PSC-A64GT) CENTRAL STATION MINI (PSC-A32MN) Individual WRC clock synchronization - - -
Connectivity Ethernet + 4G (*9) - - -
∙ Control capacity: max 64 remote control group ∙ Control capacity: max 32 remote control group of IoT Functions Firmware OTA (*10)
Future Extendability - - -
of indoor units. indoor units. Web + Mobile Update

∙ Compact and optimized 170x250mm body screens ∙ Compact and optimized 120x140mm body screens (*1) One Extension Adapter (PSC-AD128EX3) enable CENTRAL STATION EX to control additional 160 RC groups /128 groups / 160 IDUs / 64 ODUs, and up to 15 adapters can connect
to one Central Station EX.
fitting in even small walls. fitting in even small walls. (*2) No restriction on the number of H-LINK.
(*3) Individual Feature Control in Each Remote Controller is not available.
∙ Easy monitoring with simplified interface. ∙ Easy monitoring with simplified interface. (*4) Applicable only with Schedule function or external signal input. You cannot set it up directly from monitoring panel.
(*5) Main 5 functions meaning: 1) Run/Stop 2) Operation mode 3) Temperature setting 4) Fan speed 5) Louver control.
∙ Best option for middle size buildings. ∙ Best option for small size buildings. (*6) Ability to connect unlimited number of "HC-IoTGW" in one project and control all AC units via one single screen on Web or Mobile Phone.
(*7) Unlimited creation of zones, across multiple "HC-IoTGW" units within the same project.
(*8) Visualization of outdoor unit energy consumption. 60
(*9) 4G available through optional 4G module; 4G module package comes with global SIM and pre-paid global data plan.
(*10) OTA: Over-the-air firmware update, provides always up-to-date firmware and latest functionalities.
(*11) Mini , EZ : Accumulated operation time ( min ) , Accumulated thermo - ON ( min ). 61
EX : A
 ccumulated operation time ( min ) , Accumulated thermo - ON time ( min ) , Average air intake temperature of indoor unit , Average air intake temperature of outdoor unit , Average setting
temperature , Average RC sensor temperature.

CENTRALIZED CONTROLLERS

[Gateway]

Control is in your hands.


24/7 control at your fingertips on smartphone, tablet, or PC.

✓ Intuitive simplicity

200mm
For stand-alone airCloud Pro is designed to make your job easier.

SET FREE mini HNSQ Series


and multi-site An intuitive app that anyone can use, airCloud Pro
applications. makes managing your VRF systems easier than ever
Specifications
before.
Gateway HC–IoTGW
Net weight (g) 540
Connection capacity 16 outdoor + 80 indoor units
Power supply (V) | (Hz) 100-240, AC | 50/60
✓ Control from anywhere
Max. power consumption (W) 10
Communication port 1 H-LINK, 1 RS485 Port
Android IOS
Enjoy the freedom of remote access from your
Internet connection LAN (Ethernet) or 4G*3 smartphone, tablet or laptop. airCloud Pro allows
138mm External interface (log storage) 1 micro SD card slot
Lateral view: 41mm
you to remotely control your VRF system(s) from a
single app, saving you travel time.

Functions
• Access via smartphone app or web • On/Off • Mode • Set temperature
IoT connection • Air intake temperature • RC sensor temperature (*3)
• Unlimited number of gateways
(cloud-based) • Air intake temperature of outdoor unit
• Unlimited number of locations Monitor Function
• Unlimited number of users • Fan Speed • Louver • RC prohibition

• Per entire location


• Thermo-ON information • Filter sign/Auto cleaning fault
• Alarm status/Alarm codes A simple yet powerful tool.
Operation unit • Per system • Weekly schedule • Easy selection of days and zones
• Per zone (unlimited zone creation) • Setting items in schedule is as below; • On/Off

CENTRALIZED CONTROLLERS
Schedule function
• Per indoor unit remote control group • Operation mode • Setting temperature
• Louver • Fan speed
Simplify your job Save more energy
• On/Off • Mode • Set temperature
Control function • Fan speed • Louver • RC lock * “All Groups Run/Stop” command signal exception function for selected groups is available by The pilot app makes managing Monitor energy consumption
• Filter sign reset “Exception of Run/Stop Operation.” function. your VRF systems easy. and optimize usage.

• Centralized control • Energy consumption data*2


Control your entire VRF system Simple gr aphs visualize power
System configuration. Recommended facilities (examples.) or selected zones in one touch. consumption.
• Simplified troubleshooting • Intuitive scheduling
A clear error history, concise Plan operations ahead based
Ethernet error description and follow-up. on your business hours.
or 3G / 4G*3
OFFICE HOSPITAL SCHOOL/ • Smartphone alerts*2 • Individual controller lock
COLLEGE In the event of a critical Prevent inappropriate usage
malfunction. from occupants.
H-LINK • Flexible user management*2
Add users and custom access
From web airCloud To your VRF restrictions.
or app gateway system
RESTAURANT HOTEL RETAIL
Create better comfort Easy plug-and-play
Adjust temperature, fan speed, Our airCloud gateway makes
Is Cloud Pro for me? Future-proof and modes with ease, creating installation a breeze.
+ data security
total comfort and the ideal
All VRF users can enjoy these benefits! With updates and new features added regularly, climate throughout your Connect to the airCloud via
Best-in-class standards:
building. 3G/4G*3 or ethernet and pair
∙ Save energy airCloud Pro ensures you are always up to date. TLS.v1.2, HTTPS 2038 encryption.
your VRF systems via QR code
∙ Save time and unnecessary transportation 
An integrated weather forecast*2 scan. With automatic detection
∙ Delegate VRF systems administration Minimal personal details:
∙ Compatible with new and former display helps you determine the of indoor units and an optimized
Only your name, email address and phone number
∙ Create a comfortable climate for guests ∙ Hitachi Variable Refrigerant most suitable conditions for your installer view, configuring your
are required for login.
indoor spaces all year round. site and zones has never been
∙ Flow systems*1
quicker.
62

*1 Confirm compatibility of your VRF installation with your Hitachi Cooling & Heating representative. *2 Functions not available as of September 2019, coming soon. 63
*3 4G module available as a side accessory.

CENTRALIZED CONTROLLERS

CENTRAL STATION EX FOR LARGE-SCALE BUILDINGS (PSC-A128EX3) CENTRAL STATION EZ FOR MEDIUM-SCALE BUILDINGS (PSC-A64GT)

32.5 27.8 Capacity 25


80
55
Capacity
H-LINK 16 RC group 64
RC group 2,560 (*1) Group 64
Group 2,048 (*1) Block 4
170mm
Block 512 (*2) Indoor Unit 160
Area 512 (*2) Outdoor Unit 64
227.2mm
Indoor unit 2,560 (*1) Building Scale Small-Medium
Outdoor unit 1,024 (*1)
Building scale Large
Specifications

SET FREE mini HNSQ Series


250mm Rated Power Supply 1-, AC 100-240V, 50/60Hz
Extension adapter Energy calculation
Electrical Power Consumption 30W (Max.)
software* Communication Unit Units of Adopting for H-LINK
372mm Lateral view (mm) With easy control via an 8.5 inch color touch Lateral view (mm)
Communication Line Non-polar 2-wire
SD panel, its detailed control functionalities Communication Speed 9,600bps
For middle or large-scale buildings buildings such as such as Weekly Scheduling, Operation hours Wiring Length 1,000m (Total Length)
hotels, educational facilities, and hospitals, our Central Display 8.5-inch Wide Color LCD (Full Dot)
PSC-AS01EXC tracking, and more, help you save energy. Display Control Touch Panel
Station EX features a highly intuitive and functional PSC-AD128EX3
(*1) 1 extension adapter (PSC-AD128EX3) Up to 64 remote-controlled groups and up
12.1-inch wide, wall-mountable, color LCD screen. enables Central Station EX to control
additional 160 RC groups / 128 groups /
to 160 indoor units can be connected to the Functions
Control up to 2,560 indoor units with our proprietary 160 IDUs / 64 ODUs. Central Station EX Central Station EZ. • Run/Stop/Abnormality • Setting Temperature
H-LINK system with 15 extension adapters can connect up to 15 adapters.
(*2) No restriction on the number of H-LINK • RC Operation Prohibited Setting
(PSC-AD128EX3). Monitor Function • Accumulated Operating Time
• Operation Mode • Setting Fan Speed
Also, with energy calculation software (PSC-AS01EXC), • Setting Louver • Filter Sign • Alarm Code
Central Station EX can help you easily manage each Specifications • Run/Stop* • Fan Speed
• Operation Mode • Louver
tenant's electricity & report the power consumption Rated power supply 100~240VAC ±10% (50/60Hz) Control Function • Temperature Setting
of VRF system for each tenant. Electrical power consumption 50W (Max.) • RC Operation Prohibited
Communication unit Units of Adopting for H-LINK • Filter Sign Reset
Install by add-on software and activate, then, you Communication line Two-wire non-polar *The “All Groups Run/Stop” command signal exception function for selected
groups is available via the “Exception of Run/Stop Operation” function.
can select electricity ratio or usage ratio from several Communication speed 9,600bps
Wiring length 1,000m (Total Length)
methods.
Display 12.1 inch TFT color liquid crystal display

CENTRALIZED CONTROLLERS
Display control Touch Panel

Functions
All together
Each area
Each of the following settings is available in 3
different [annual] [summer][winter] categories:
Energy saving:
• Run/Stop
CENTRAL STATION MINI FOR SMALL-SCALE BUILDINGS (PSC-A32MN)
Operation → Weekly schedule
Each block • RC prohibition
unit → Up to 16 actions can be set per day
Each group
Each indoor unit → Exception day setting: 5 different types
• Temperature shift
(For Cool/Dry mode: +1.0°C~+9.0°C (+1.0°F~+18.0°F))
22 52.7
Capacity
→ Holiday setting (For Heat mode: -1.0°C~-9.0°C (-1.0°F~-18.0°F))
On/Off RC group 32
• Mode shift
Mode Schedule Setting items in schedule is as below: ( Mode shifted to Fan when in Cool/Dry mode, Group 32
Set temperature function • On/Off and shifted to Stop in Heat mode) Block 4 Patterns (2/4/8/16)
Fan speed • Operation mode • Capacity control on outdoor units 120mm Indoor Unit 160
Louver • Setting temperature • Lower noise control for outdoor units
Control Outdoor Unit 64
RC prohibition • Louver
function External input
Filter sign reset • Fan speed Building Scale Small
/ output Control/Monitor
Function selection for indoor units (*1) • RC operation prohibition → Controlled items:
Function selection for outdoor units (*2) • Capacity control for outdoor units
Capacity control for outdoor units (*2) • Lower noise control for outdoor units
• Run/Stop
• Mode (Cool/Heat)
140mm
Lateral view (mm) Specifications
Lower noise control for outdoor units (*2) Alarm history: 10,000 records → Monitored items:
Rated Power Supply 1-, AC 100-240V, 50/60Hz
On/Off History External In/Output history: 1,000 records • Run/Stop
Pulse input history: 6 months • Mode (Cool/Heat) Electrical Power Consumption 20W (Max.)
Mode With easy control via an 5.0 inch color touch
Set temperature Up to 2 years worth of data history can be • Alarm state Communication Unit Units of Adopting for H-LINK
Air intake temperature displayed for the following: panel, its detailed control functionalities Communication Line Non-polar 2-wire
RC sensor temperature (*3) • Accumulated operation time (min.) Others: Communication Speed 9,600bps
Monitor Air intake temperature of outdoor unit • Accumulated thermo-ON time (min.) • Power consumption signal input such as weekly scheduling, operation
Management Wiring Length 1,000m (Total Length)
function Fan Speed • Average air intake temp temperature of • Emergency stop
report hours tracking, help you save energy. Up Display 5.0-inch Wide Color LCD (Full Dot)
Louver indoor unit
visualization
RC prohibition • Average air intake temperature of outdoor (*1) Some indoor units may not fully support all functions. to 32 remote-controlled groups and up to Display Control Touch Panel
Thermo-ON information unit (*2) Available for applicable outdoor units only.
Filter sign/Auto cleaning fault • Average setting temperature 160 indoor units can be connected to the
Alarm status/Alarm codes • Average RC sensor temperature
(*3) Whether this is shown on the screen depends
on the remote controller settings. Central Station mini. Functions
• Run/Stop/Abnormality • Setting Temperature
• RC Operation Prohibited Setting
Monitor Function • Accumulated Operating Time
• Operation Mode • Setting Fan Speed
Remote access. Example: school
• Setting Louver • Filter Sign • Alarm Code"
• Run/Stop* • Fan Speed
• Operation Mode • Louver
You can now operate Central Station EX from your laptop PC or touch panel PC. Control Function • Temperature Setting
Install our software and you can connect from anywhere, using our VPN network. • RC Operation Prohibited
• Filter Reset Signal
* “All Groups Run/Stop” command signal exception function for selected groups is
Staff room available by “Exception of Run/Stop Operation.” function.
64
LAN
EX
65

INDIVIDUAL CONTROLLERS From basic to advanced controls
ADVANCED-COLOR ECO-COMPACT WIRED REMOTE ADVANCED WIRELESS WIRELESS REMOTE
CONTROLLER CONTROLLER CONTROLLER REMOTE CONTROLLER CONTROLLER

A new generation of room controller now available!


NEW PC-ARFG1 NEW PC-ARC HCWA10NEGQ PC-AWR PC-LH7QE
With two new room controllers, the experience of controls has become easier No of RC-Group 1 1 1 - -
Connection Capacity
and more stylish than ever No of indoor units 16
120×120×16.5
16
90x90x15.5
16 - -
Product Size Width*Height*Depth (mm) 88×88×15.5 140×55×16.8 140×52×19.3
(D: thinnest part) (D: thinnest part)
NEW NEW Segment LCD with Segment LCD with

ADVANCED-COLOR CONTROLLER ECO-COMPACT CONTROLLER


Screen Color LCD with backlight Segment LCD Segment LCD
backlight backlight
Embedded IR receiver - - - -
(PC-ARFG1-*) (PC-ARC-*) Smartphone App Use With Aircloud Tap (support NFC ) (support NFC ) - - -
Run / Stop
Operation Mode
Auto Mode Setting
Essential Operations
Temperature Setting
Fan Speed

SET FREE mini HNSQ Series


Louver Direction
Simple Timer (On/Off Timer) (On/Off Timer) (On/Off Timer) (On/Off Timer)
Weekly Operation Schedule - -
Contactless settings via Contactless settings via Power Savings Setting (Capacity Control only) - - -
Night Quiet Operation - - - -
Power Savings/Night Quiet Schedule - - - -
Power Consumption Display - - - -
AutoBoost - - -
Complete controls in a rich interface Value without compromise Comfort Setting
Sleep Mode -
(GentleCool only) -
-
-
-
-
-
∙ Colored screen displaying visual charts and descriptive texts ∙ Segment screen displaying pictograms Advanced
Feature Settings
Motion Sensor Setting (1) - - - -
Setback Setting - - - -
∙ Access to all existing Hitachi VRF indoor unit features ∙ Essential controls in a glimpse Elevating Grille - - - -
including user features settings, installation & maintenance ∙ On/Off weekly schedule Filter Reminder Time Reset
Filter Auto-Cleaning (1) - - - -
features settings. ∙ Some extra advanced features such as GentleCool, FrostWash Setting (1) - - - -
∙ Energy consumption monitoring Power-Saving Peak-Cut mode and Sleep Mode Timer Individual Louver Setting - -
Louver Open/Close - - - -
∙ Ideal for indoor units with motion sensors, cassettes with ∙ Embedded IR receiver, ideal for ducted units Ventilation - - - -
elevating grilles Total Heat Exchanger SET - - - -
Adjusting Date/Time - -
∙ Multiple languages available Daylight Saving Time - - - -
*Except Sleep Mode timer Run Indicator Brightness Adjustment (Only On/Off setting) - - -
Display Adjustment - - - -
Temperature Units (°C/°F) - (°C only)
Display Settings
Temperature setting at 0.5°C step - (1.0°C only)

Still available for order Room Temperature Display


Language available
EN, JPN,CN (traditional
EN EN
-
EN EN
-

INDIVIDUAL CONTROLLERS
&simplified),FR, ES,PT

WIRED REMOTE CONTROLLER Keypad Touch Sound


Lock Function (Lock function individually)
(Cannot turn off)
(Lock whole keypad)
-
-
-
-
(HCWA10NEGQ) Password Setting - - - -
Hotel Mode - - - -
Power Saving Details Setting - - - -
∙ 88mm square controller Temperature Range Restriction (in Function Selection) (in Function Selection) - -
Service Functions Dual Setpoint - - - -
with LCD screen. Main/Sub Display - - - -
∙ Smaller body with Set Room Name - - - -
Set Contact Information - - - -
multiple features. NFC Setting - - -
∙ Best option for spaces Simple Maintenance Check Menu
Test Run
- - -
-
-
-
frequented by recurring Function Selection - -
users, e.g. offices. Thermistor Selection
Input/Output
(in Function Selection) (in Function Selection) -
-
-
-
Thermistor Calibration in Controller (in Function Selection) - - -
Fan Speed At Thermo-Off (in Function Selection) (in Function Selection) - -
Indoor Unit Address Change - -
Address Check Operation - - - -
Installation Functions Address Initialization - - - -

Controls from anywhere in the room


Setting Initialization - - -
Main/Sub Controller Setting - -
Priority Setting - - -
Cancel Preheating Control - - - -
ADVANCED WIRELESS REMOTE WIRELESS REMOTE CONTROLLER Elevating Grille Setting
Power Up Setting
-
-
-
-
-
-
-
-
CONTROLLER (PC-AWR) (PC-LH7QE) Setback Trigger Unit
Refrigerant Leak Sensor Setting
-
-
-
-
-
-
-
-
∙ Wireless remote controller ∙ Budget option featuring Check 1 - -
Check 2 - -
with more features. primary control settings. Alarm History Display - -
Check Menu
∙ Several temperature units ∙ 1.0°C temperature step. Display Model Number
Check PCB of the Units
-
-
-
-
-
-
-
-
and settings available; ∙ Ideal for visitors to control Self Check - - -

0.5°C/1.0°C/1.0°F. the unit from anywhere Synchronize Date/


(Only avaible from
Central Station EX
(Only avaible from
Central Station EX - - -
time with Central Controller
∙ Ideal for controlling the in the room, e.g. hotel PSC-A128EX3) PSC-A128EX3)
Stop operation delay - - -
unit from anywhere suite. Other features
Emergency operation - - -
in the room, e.g. Two WRC Control - - -
Alarm Display - -
residential spaces. Filter cleaning reminder sign display - - 66
(*1) Available when the controller is connected with selected indoor unit offering this feature.
67

INDIVIDUAL CONTROLLERS

What you can do with airCloud Tap | some highlights:

Installation & Commissioning Operation Maintenance & Service


NEW

For HVAC professionals:


Quicker commissioning &
service by airCloud Tap

SET FREE mini HNSQ Series


Contactless ‘read and write’
settings

Ready-to-tap controllers
∙ NFC chip embedded in the controller

Convenience using with


a mobile app
Date/time setting Function selection Scheduling Troubleshooting Temperature range
∙ Easy browsing of all settings by scrolling
restrictions
phone’s screen
∙ Complete text description of each setting import the date & time Scroll your phone’s Save preferred AC Visualize all the  pply min/max set
A
from your phone into screen and schedule and save service check data on temperature to
More savvy than traditional the controller browse over 140 to copy to other your phone prevent excessive
settings by physical device commissioning controllers of the cooling/heating
∙ Less buttons to press, no AC hardware to settings available same building
manipulate

INDIVIDUAL CONTROLLERS
∙ Time saving setting process
∙ Reduced need of documentation support

Special tip: Save time on multi-room commissioning

Specify settings for one room, save them, then apply these settings to other similar rooms in one tap. Particularly useful for multiple zones with
similar needs! Hotel guestrooms, office meeting rooms, condominium units, etc.

How does airCloud Tap works?

STEP1 STEP2
Read the settings from one device Hold the mobile device over each product and
and save settings. write settings of STEP1.

Paste Paste Paste Paste Paste Paste


Copy Copy settings settings settings settings settings settings

1. Activate the NFC function on 2.Open the airCloud Tap app 3. Edit the desired settings on 4.Tap again your equipment to
the AC equipment. and tap the AC equipment with your phone. apply the new settings.
your phone to read the current
settings.

68

69

INDIVIDUAL CONTROLLERS
NEW

ADVANCED COLOR WIRED REMOTE CONTROLLER (PC-ARFG1)


Energy optimization
Power-saving features enable VRF system operators to optimize energy usage
Simplicity with style
Combining the best of form and function, enjoy climate control made easy With Near-field communication
[dd] kWh Power Consumption Mon PM05:34 Capacity Control Power Saving Mode
Capacity Control ON/OFF
Power Saving Setting
: ON
100
with Hitachi’s most advanced wall controller yet. (NFC) contactless-enabled system 50
Rotation Control Mode Selection : Intermittent Control
MED : 50% Level : LOW
commissioning via the airCloud OK Intermittent Control

Tap smartphone app, you can 0 2 4 6 8 10 12 14 16 18 20 22

now save, copy, and paste settings


Today 1day before

OK List 2d ago Adjust Back Back OK Select Back OK Enter Back

to the Advanced Color Controller


Super user-friendly interface Energy consumption visualization Capacity – peak cut control Choice of power-saving method Power saving setting
with a simple tap.

SET FREE mini HNSQ Series


Set specific schedules for features like peak capacity cuts and the thermal operation rotation of indoor units, enabling you to match energy-
Easy-to-navigate menus saving operation hours with your utility tariffs plan. Building managers can also set the minimum and maximum temperature range for
occupants and visualize energy consumption with daily, weekly or monthly comparison options.
Available in 7 languages

Pictograms and colors for an


From basic to advanced functions
optimal user experience
Users can control the main GentleCool Comfort Autoboost Operation Schedule Mon PM05:34

Not Set Not Set 0 6 12 18


temperature settings from Mon
Award-winning design LOW LOW Tue

Advanced-Color controller's MED Heat


Wed

• Minimalist design aesthetic HIGH Cool + Heat


Thu
Fri

• Distinctive curves for ergonomics main screen. In addition, more Sat


Sun

• Modern and subtle colors advanced comfort settings OK Select Back OK Select Back OK Select Back

help customizing the air to GentleCool limits the temperature AutoBoost automatically activates AC Scheduling is easier than ever,
their occupants' specific of conditioned air, preventing cold for 30 minutes every time the AC is thanks to flexible features such as
drafts for optimal comfort. turned on, helping the room reach the holiday calendar.
needs.
the desired temperature faster.

INDIVIDUAL CONTROLLERS
1 Room name Outer dimensions (H×W×D)
2 Set temperature 120×120×16.5mm (thinnest part)
1 12
3 Operation mode
The latest VRF features
120×120×21.5mm (thickest part)
2
4 Indoor unit ON/OFF light
Installation Menu FrostWash Setting 01-01 Function Menu
5 Indoor unit ON/OFF Fan Speed at Cooling Thermo-OFF 1 2 3 4 Simple Timer
2
6 Navigation buttons Capacity Fan Speed at Heating Thermo-OFF
Start Frost Wash
Start
Auto
Main the
RCS FrostWash
Clearning
cannot Now?
beStart/Disable
detected. Operation Schedule
3 9 10 11 Indoor Unit Address Change Press OK Wash
Frost to set this as Main RCS.
Intervals OK Power Saving Setting
7 Back button Power Supply Powered by indoor unit, 15VDC±10% Indv. Indv. Indv. Indv.
Address Check Operation Frost
YesWash Available
CancelTiming Night Quiet Operation
OK
4 8 OK button 180g (approx.) Address Initialization Frost Wash History Power Sav./Night Quiet Schedule
Adjust air direction & louver angle.
8 Installation Indoor, on the wall or switch box
9 Fan speed OK Enter Back OK Confirm Back Back OK Enter Back
7 Connection capacity Up to 16 indoor units (with the same wired remote controller)
5 6 10 Louver direction When two wired Advanced Controller units are connected to the same indoor
Fan speed at thermo-off Activate, schedule and check Individual 4-way cassette louvers Schedule Night Quiet mode
▲ Display reduces air circulation when the history of indoor units’ optimizes air flow direction to each to minimize the outdoor unit’s
11 Access to menu unit, the maximum brightness of each controller will be halved
cooling or heating is not FrostWashTM function. corner layout. operation noise so you and your
12 Filter cleaning reminder
*H is the height of the unit from the front, without the effective. neighbors get a better night’s sleep.
protrusion at the bottom.

Special features for hotels


System configuration example Hotel mode enables instant access to the functions demanded most
by hotel guests. After guests check out, housekeeping can reset the
Possibility of 2 Wired Controller Connection Up to 16 IDU connection
controller in one touch.
Hotel setback allows interlocking with hotel key cards. When the
room is vacant, the indoor unit switches to a selected energy-saving
setback temperature, ensuring the room remains
at a comfortable temperature when unoccupied.
2 RCcontrol
is available ........

Simultaneous control for up to 16 IDU with transition wiring Ideal for indoor units with motion sensor features
Active intelligent comfort features connected to your indoor unit’s motion sensor and/or radiant sensor*: choice of direct/indirect air flow, FeetWarm
Primary RC Secondary RC H-LINK
NEW, FloorSense Cool NEW and the exclusive Crowd-Sense NEW to prevent heat peak from rapid crowd arrival. 70
Remote Control Cable

71

INDIVIDUAL CONTROLLERS
NEW

ECO–COMPACT CONTROLLER (PC-ARC-*)


Easy access to essential controls
Simplified navigation enables users to change temperatures
Climate control in a compact size and adjust essential controls directly from the home screen
• Great value for money that combines the best of form and function. With Near-field communication in one touch.
• Minimalist design aesthetic that reflects Hitachi’s Duality Design philosophy. (NFC) contactless-enabled system
Operation modes
commissioning via the airCloud Tap
smartphone app, you can now save,
copy, and paste settings to the Eco-
Budget-sensitive VRF projects Compact Controller with
a simple tap.

SET FREE mini HNSQ Series


Users who prefer simple controls
Fan speed

Functional spaces

Set temperature with 0.5°C precision*


Stylish & Intuitive Louvers’ positions
With distinctive curves and an aesthetic
inspired by Hitachi's Duality Design philosophy,
the Eco-Compact Controller is stylish, ergonomic,
cost-effective, and convenient.
Enjoy climate control made easy through an Energy-saving features Accrued comfort
optimized interface with easy-to-understand
The Eco-Compact Controller includes energy-saving features The Eco-Compact Controller includes energy-saving features
pictograms for a truly intuitive user experience.
to minimize unnecessary AC operation. to minimize unnecessary AC operation.

The Peak-Cut feature enables users to save even Include GentleCool, which controls the
more energy during peak consumption periods. discharged air temperature for a smooth
cooling down and prevents cold drafts.

INDIVIDUAL CONTROLLERS
Low Med High
1 Set Temperature Outer dimensions (H×W×D)
1 2 Operation mode 90mm×90mm×15.5mm(thinnest part)
11 Weekly scheduling automatically turns the indoor AutoBoost activates for 30 minutes every time the AC is turned
3 Run indicator 90mm×90mm×18.5mm(thickest part) unit on/off at set times, great for classrooms, retail on, helping the room reach the desired temperature faster
4 On/Off button businesses or other premises with regular opening with a powerful automatic mode, which is ideal for meeting
5 Operation mode button hours. rooms and other areas requiring fast temperature reach.
6 Fan speed button Capacity
2
10
7 Menu buttons Power Supply Powered by indoor unit, 15VDC±10%
3 9 8 Directional key 100g (approx.)
Installation Indoor, on the wall or switch box
9 Fan speed
10 Louver direction
Connection capacity Up to 16 indoor units (with the same wired remote controller)
Supports easy Special features
4 5 6 7 8
11 Current time maintenance For residential users: For hotels:
set the Sleep mode timer NEW interlock the Eco-Compact Controller
A filter symbol appears when it’s time
to gradually change the room with your hotel key card receiver and
to clean the filter.In the event of an temperature for a better night's activate setback temperature while
error, the error code and the related sleep. The unit will turn off guest is away.
automatically after a set time.
indoor unit number is clearly displayed

System configuration example for ease of maintenance.

1 2
Possibility of 2 Wired Controller Connection Up to 16 IDU connection

3 Embedded IR receiver
4
For use with the Wireless
Remote Controller. Ideal
2 RC control for indoor units without
is available ........
embedded IR receiver
(ex: ducted units)
Simultaneous control for up to 16 IDU with transition wiring
1 Alarm Icon
H-LINK
2 Indoor Unit No.(Refrigerant system) Wireless Remote Controller
Primary RC Secondary RC (sold separately)
3 Indoor Unit No.(Refrigerant system) 72
Remote Control Cable
Over the closet In dropped ceiling, over window
4 Alarm Code When IR receiver receives the commands, the buzzer sounds. 73
*Compatible HCRB10NEWQ​and PC-LH7QE/PC-LH7QE1 wireless controllers

INDIVIDUAL CONTROLLERS

WIRED REMOTE CONTROLLER (HCWA10NEGQ) ADVANCED WIRELESS WIRELESS


REMOTE CONTROLLER (PC-AWR) REMOTE CONTROLLER (PC-LH7QE)

Temperature display Outer dimensions (H×W×D) Transmitter Transmitter


Room temperature
(mm) 88.0×88.0×15.5
Transmitting indication
Transmitting indication
Set temperature LCD (Liquid Crystal Display)

Liquid Crystal Display Functions LCD (Liquid Crystal Display)


Mode selection switch Fan speed switch
(LCD) screen
Run/Stop Reset switch On switch Run/Stop switch
ON/OFF button Operation Mode Off switch Temp. switch

Mode button Up button & down button Auto Mode Setting


Louver angle switch

SET FREE mini HNSQ Series


Setting Temperature Setting Louver angle switch
Timer switches Temp. switch Timer switches
Operation mode Temperature Setting Rate 0.5°C/1.0°C/1.0°F
Filter reset switch
Fan Speed 3/4/6 taps
Cooling mode Louver Direction
Reset switch
Sensor Condition Check
Heating mode Service Sensor Data Check
Alarm History Display
Dry mode Test Run
Fan speed setting Timer/Clock setting
Function Selection (Optional Function Setting)
Fan mode Thermistor Selection
Fan speed Timer setting Test Run
Thermistor Calibration
Outer dimensions (H×W×D) (mm) 140.0×55.0×16.8 Outer dimensions (H×W×D) (mm) 140.0×52.0×19.3
Auto mode Input / Output Setting
(flickering) Timer ON
Indoor Unit Address Change Functions Functions
MAX Timer OFF key pad lock
Run/Stop Filter Sign Reset Run/Stop Side-by-side indoor
Timer valid for one time Management Lower Limit for Cooling Operation
Operation Mode Side-by-side indoor Operation Mode Service unit identification
Timer valid for one day Upper Limit for Heating Operation Service
Auto Mode Setting unit identification Auto Mode Setting Temperature Unit °C
Timer set for a week Simple Timer (On/Off)
Schedule Temperature Setting Temperature Unit °C/°F Temperature Setting Schedule Built-in Timer (On/Off)
Date/time setting Setting Setting
Temperature Setting Schedule Built-in Timer (On/Off) Temperature Setting
Rate 0.5°C/1.0°C/1.0°F Rate 1.0°C
Fan Speed 3/4/6 Taps Fan Speed 3/4/6 Taps
Notes: Louver Direction Louver Direction
1. Fan speed taps setting unit availability varies with the indoor
MIN unit. Please check each technical catalog in advance.
2. Initial setting of temperature display is "Set temperature"
display only. Please contact your dealer to display room
temperature.

INDIVIDUAL CONTROLLERS
RECEIVER KIT FOR WIRELESS REMOTE CONTROLLER

PC-RLH11 (Basic) PC-ALHZ1 (Advanced)

Model

Ducted Ducted Ducted Ducted Compact


Wall-Mounted Floor / Ceiling
High ESP Medium ESP Low ESP Floor Concealed
Indoor unit AC Motor DC Motor (DC Motor) Convertible
(AC Motor) (AC Motor) (AC Motor)
RPIH-HNAUN1Q RPIM-HNAUN1Q RPIL-HNAUN1Q RPIZ-HNATN1Q RPIZ-HNDTS1Q RPK-HNBUSQ RPFC-FSNQ RPFI-FSNQ
Advanced Wireless
Remote Controller
PC-AWR
Standard Wireless
Remote Controller
PC-LH7QE

HR4A10NEWQ PC-ALH3 PC-ALHC1 P-AP56NAMR PC-ALHD1 PC-ALHS1 PC-ALHP1 PC-ALHZ1


(Basic) (Advanced) (Advanced) (Advanced) (Advanced) (Advanced) (Advanced) (Advanced)

Model

4-way 4-way 4-way compact 4-way compact 2-way 1-way


Ceiling Suspended Wall-Mounted
Indoor unit Cassette Cassette Cassette Cassette Cassette Cassette

RCI-FSKDN1Q RCI-FSRP RCIM-FSRE RCIM-FSRE RCD-FSR RCS-FSR RPC-FSR RPK-FSRM


Advanced Wireless
Remote Controller
PC-AWR
Standard Wireless
Remote Controller — — — — — — —
PC-LH7QE

Basic Limited function available for centralized controllers


Temperature setting rate [1.0°C] only
Advanced F ull function available for centralized controllers
Temperature setting rate [0.5°C/1.0°C/1.0°F] 74
(*) Basic function receiver kit is installed as a standard part in this wall-mounted unit. Wireless remote controller (PC-LH7QE) is delivered as a standard accessory as well.
If separate placement of receiver kit is required, please use optional basic receiver kit [PC-RLH11] or optional advanced receiver kit [PC-ALHZ1]. 75
Notes:
When using a basic receiver kit PC-RLH11 or HR4A10NEWQ together with wireless remote controller PC-LH7QE:
1) It won't be possible to lock individual remote controllers from Hitachi Central Stations (mini/EZ/EX)
2) It won't be possible to apply min/max restrictions on set temperature from Hitachi Central Stations (mini/EZ/EX)

ACCESSORIES

Specifications
Operation example
Outer dimensions (H×W×D)
∙Cooling operation: ∙Heating operation:
(mm) 68.0×240.0×154.0
Compressor is ON by closing terminals 2 Compressor is ON by closing terminals 1
and 3 of CN3. and 2 of CN3.
3P CONNECTOR CABLE BMS ADAPTER FOR BACNET® Functions
Compressor is OFF by opening terminals Compressor is OFF by opening terminals
(PCC-1A) 2 and 3 of CN3. 1 and 2 of CN3. ( HC-A64BNP1) Corresponding ANSI/ASHRAE Standard 135-2004 • Run Stop (State)
BACnet® Standard BACnet® • Operation Mode (State)
• Run Stop (Setting) • Fan Speed Level (State)
FOR CONNECTION TO REMOTE ON/OFF *One set contains five 3P connector cables. CONTROL UP TO 64 INDOOR UNITS • Operation Mode (Setting) • Indoor Temperature (State)
Control Item at • Fan Speed Level (Setting) Monitoring Item at • Prohibiting RC Operation (State)
DEVICE/RECEIPT OF OUTPUT SIGNAL *PCC-1A can connect to external signal input-output terminal both in outdoor unit and indoor unit.
Upper System • Indoor Temperature (Setting) Upper System • Filter Signal
• Indoor Air Intake Temperature
System configuration example
• RC Operation lock (Setting)
• Filter Sign Reset • Alarm Signal

SET FREE mini HNSQ Series


• Alarm Code
• Communication State

«PCC-1A» 3
2
1
System configuration example
Thermostat
3 CN3 H-LINK
2 Remote control cable
1 BACnet ®

Temperature
increase Field-supplied
Remote ON/OFF device
Indoor unit PCB Fire
Lighting alarm Lift Ventilation

H-LINK Centralized
controller
Remote control cable

Outer dimensions (H×W×D) Length m 8.00

(mm) 50.0×50.0×15.0
BACnet ®

System configuration example

ACCESSORIES
HC-A64BNP1

*When the room temperature thermistor (remote sensor) is connected


REMOTE SENSOR (THM-R2A) to the auxiliary connector, the unit is controlled at average air
temperature at the indoor inlet and remote sensor point.
ROOM TEMPERATURE SENSOR *Not compatible with wall type(RPK) indoor unit.

H-LINK
«THM-R2A»
Remote sensor cord

PRC-5K PRC-10K PRC-15K


Length m 5.00 10.00 15.00

System configuration example

REMOTE CONTROL CABLE H-LINK


Remote control cable
(PRC-5K, 10K, 15K)

FOR PC-ARFG1 CONNECTION (TO IDU)

«PRC-5K, 10K, 15K»

*PC-ARFG & PC‑ARF1 does not include


50mm 100mm a remote control cable.
Shielded twist-pair cable 76
Use this cable if you don’t have one
available in your field. 77

H-LINK: ENJOY MORE FREEDOM

WHAT IS H-LINK? Examples CENTRALIZED CONTROLS: FLEXIBLE WIRING ROUTE!


H-LINK is Hitachi Cooling & Heating original communication Educational institutions such as primary
(1)• M
 ultiple refrigerant systems
system to control multiple VRF refrigerant systems from one schools where installation work cannot
located in one area.
be performed on weekdays.
centralized control point. • Central monitoring room in
separate area.
H-LINK simplifies commissioning and service maintenance for installers and  otels where it is preferable to complete
H
H-LINK SOLUTION
service engineers. For building owners and occupants, it provides outstanding installation work during late evenings.

Wire the central station
versatility enabling the connection of various types of central control options, to the closest indoor unit.
enabling better system management. Our proprietary high-performance Wiring distance is reduced
substantially.

SET FREE mini HNSQ Series


communication system enables the connection of control wiring between
Rehabilitation facilities or hospitals
indoor and outdoor units, and between a centralized control system and
where it is necessary to minimize the
indoor/outdoor units across two or more refrigerant systems.
burden on users. CENTRAL CONTROL
ROOM AREA 1

(2) • Refrigeration systems

3x
in different places.
1 2 3 • Some indoor units of each
respective system are close
Flexible wiring Can connect to one another.
No adapter
routes: with various types of
is needed! H-LINK SOLUTION

more
no restrictions & Hitachi air conditioning
products, including VRF Simple connection 
Where two indoor units
time-saving of each respective system
and mini splits, to terminal blocks. are close together: you

benefits! at installation.
for centralized controls.
can connect two
refrigerant systems via
the indoor units.
Wiring distance is
CENTRAL CONTROL
reduced substantially.
ROOM AREA 1 AREA 2

H-LINK: ENJOY MORE FREEDOM


(3) • One refrigerant
Definition of terms in Hitachi centralized control systems system far away
from theremaining
Outdoor unit
ones.

H-LINK SOLUTION
Connect the farthest
Indoor unit refrigerant system
directly to central station
either to outdoor units
or indoor units.
The central station
can make the central link
between the different
refrigerant systems.

CENTRAL CONTROL
2 2 2 2 2 AREA 1 ROOM AREA 2
RC Group RC Group RC Group RC Group RC Group
1
CS-NET
3 3
Group Group
(4) • Each refrigerant
4 system in separate
Block areas.
1 CS-NET/Central station
• Indoor units are
Hitachi original centralized controller. closer from one
2 RC Group (Remote Controller System Group) group to another.
 tands for a number of indoor units (up to 16 units) connected using "same remote controller" wiring.
S H-LINK SOLUTION
In this group, connected indoor units are all controlled in the same way.  entralized control can
C
be achieved by connecting
3 Group the refrigerant systems
via the closer indoor units.