CLPS76eN-BAS STEAM
High Temperature Rack Conveyor
Dishwashing Machine
71 1/2" 72 9/64"
P2 P2
41 15/32" 55 1/2"
E1 E2
32 3/4" 47 13/16"
E2 E1
P4 42 7/16"
23" 23" 30 15/16" P5
P5 45 1/5" OPEN DOOR OPEN DOOR
CLEARANCE CLEARANCE
34 11/16" P4
P3 62 1/2" 64 9/32" P3
20" SERVICE 20" SERVICE
CLEARANCE CLEARANCE
(BOTH SIDES) (BOTH SIDES)
Top View Left to Right Top View Right to Left
10" 75 3/8"
10" V1 TYP V1
75 3/8"
TYP 5"
9 11/16" 9 11/16"
5" 21 5/8" 21 5/8"
7 3/8 7 5/8"
P1 P1
Front View Left to Right Front View Right to Left
31 1/16"
22"
BOTH ENDS WIDTH OF 27"
MACHINE WIDTH OF 20" AVG INSIDE
27" CL
TRACKS TABLE WIDTH
11"
14 1/2"
WALL FRONT OF
MACHINE
CL MACHINE 2 HOLES FOR BOLTING
TABLE TO TANK
1 1/4"
8" AVG 3/8"
7 3/8"
LEGEND SPECIFICATIONS
Electrical Connections Capacities
Motors and controls 1-1/4" or 2" conduit, Racks per Hour (NSF rated). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
E1
63-3/4" AFF. Wash Tank (U.S. gallons). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Internal electric booster 1-1/4" or Power Scrapper (U.S. gallons). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
E2
2" conduit, 63-3/4" AFF. Conveyor Speed (feet per minute) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.8
NOTE: Common electrical connection (single point) Motor Horsepower
available, see page 4 for details. Booster information, Drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/6
see page 4.
Wash. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Plumbing Connections Power Scrapper. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Drain. May be drained to either side
Water Consumption
of valve, plug opposite side 2" FPT.
U.S. Gallons per Hour (maximum use at 20 PSI). . . . . . . . . . . . . . . . . . . . . 138
P1 Recommend a floor drain minimum
of 12'' from machine for access and U.S. Gallons per Rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.56
maintenance. 7-3/8" AFF. Peak Drain Flow (U.S. gallons per minute). . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Hot water. 1/2" FPT connection. Heating
P2 1/2", 11-3/16" AFF. See plumbing notes Tank Heat, steam coils (pounds per hour). . . . . . . . . . . . . . . . . . . . . . . . . . 65
for required temperatures. Optional Electric Booster (built-in) (kW for 40°F rise) . . . . . . . . . . . . . . . . 15
Optional cold water connection for drain Optional Electric Booster (built-in) (kW for 70°F rise) . . . . . . . . . . . . . . . . 30
P3 water tempering 1/2" FPT, cold water Optional Steam Booster (external) (pounds per hour) . . . . . . . . . . . . . . . . 60
temperature 80°F, maximum 7-3/8" AFF. (If used on 20 PSI steam, 20 PSI water flowing,
130°F entering water raised to 180°F minimum)
Steam Connections
Steam coils: 10 to 50 PSI flowing, Venting
P4 Load End (minimum CFM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
3/4" FPT, 11-18" AFF.
Condensate return: A 10 PSI minimum Unload End (minimum CFM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
differential pressure across the steam Shipping Weight (approximate). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 890 lbs.
P5 trap must be maintained. 3/4" FPT, Crated Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86"L x 38"W x 78"H
11-1/8" AFF one connection.
(One bucket type trap furnished).
Vent Connections
Optional vent hoods, 4" x 16" vent stack
V1
with damper.
Electrical Connection
E1
(3 PH only) Motors and Controls
Minimum Maximum
Rated
Voltage Supply Circuit Protective
WARNING: Plumbing and electrical connections Amps
Ampacity Device
should be made by qualified personnel who will
208/60/3 16.6 20 20
observe all the applicable plumbing, sanitary, safety
240/60/3 16.6 20 20
codes and National Electrical Code.
480/60/3 9.4 15 15
Plumbing Notes: Minimum incoming water temperatures: 600/60/3 8.4 15 15
110°F for 30kW internal booster, 140°F for 15kW field
converted internal booster, 180°F without internal
booster. Building flowing water pressure to dish machine CLPS76eN-BAS Steam Heat Dissipation
is 20 PSI, (+/- 5 PSI). For non-booster machines, a PRV BTU/HR.
Booster
with internal expansion bypass is required. Latent Sensible
Without Booster 18,900 8,100
Steam Heat Only: Flowing steam pressures above 50 PSI
must have a pressure regulator (by others) installed in the 15kW Booster 32,500 13,900
steam line. 30kW Booster 46,000 19,700
COMMON ELECTRICAL CONNECTION (SINGLE POINT) – CONTACT FACTORY FOR ADDITIONAL INFORMATION
Common Electrical Connection
(Includes Motors & Controls and Electric Booster Heater)
MACHINE AND 15kW BOOSTER MACHINE AND 30kW BOOSTER
Voltage Minimum Maximum Minimum Maximum
Rated Rated
Supply Circuit Protective Supply Circuit Protective
Amps Amps
Ampacity Device Ampacity Device
208/60/3 61.3 80 80 100.2 110 110
240/60/3 61.3 80 80 100.2 110 110
480/60/3 9.4 15 15 49.5 70 70
600/60/3 21.9 35 35 42.1 55 55
VENT HOOD OPTIONS (Adjustable, vent stack can be adjusted 1" to either side)
Standard Short Extended
10" 10" 10"
20 1/2"
OUTSIDE
REF
As continued product improvement is a policy of Hobart, specifications are subject to change without notice.
F40809 (06/19) Page 4 of 4 HOBART • 701 S Ridge Avenue, Troy, OH 45373 • 1-888-4HOBART • www.hobartcorp.com Printed in U.S.A.