Description
These 2-wire (loop-powered) I/P transmitters accept a
current signal (such as 4-20mA) from a DCS, PLC or
PC-based control system. They convert the current
signal to a pneumatic signal (3-15psig, 0.2-1bar,
20-100kPa, etc.) to provide precise, proportional
control of valves, actuators and other pneumatically-
controlled devices.
The economical IPH2 (Type 4X) is
watertight, dust-protected, and resistant to corrosion
and chemicals. In addition to meeting Type 3X/4X
requirements, the IPX2 can be installed in explosion-
proof environments.
Both units are available with an optional
coalescing filter/regulator that combines an air filter
Compact, rugged, and highly accurate, the IPH2 (right)
and miniature supply line regulator with a pressure
and IPX2 (top) are ideal for installation in harsh field
gauge that reads in both psig and bars. environments.
Figure 1. I/P transmitters accept a current input and convert it to a propor- ■■ Accurate and stable. Featuring exceptional
tional pneumatic control signal. ±0.25% of span accuracy and six-month stability,
they are ideal for precise applications in difficult to
Current-to-Pressure (I/P) access locations.
Transmitter
■■ Immune to supply pressure variation. Maintain
incredible accuracy even when the supply pres-
PC sure fluctuates between 20 and 40psig.
---------➤ ➤
*Maximum natural gas bleed rate is less than 6SCFH with a 3-15psi ■■ RFI/EMI protection. Special circuit and enclo-
output and 17psi natural gas supply. sure designs protect against the harmful effects of
radio frequency and electromagnetic interference.
© 2018 Moore Industries-International, Inc. Page 1
170-710-06N
IPH2 & IPX2
Type 4X & Explosion-Proof
Current-to-Pressure (I/P) Transmitters
Specifications
Performance Accuracy: <±0.25% of span Performance Voltage Drop: Ambient Operating & Storage
including the combined effect (Continued) 5V, maximum Conditions Range:
of linearity, hysteresis and Air Consumption -40°C to +85°C
repeatability (between (Dead-ended): (-40°F to +185°F)
0 and 3psig output, error will At 3-15psig output 20psig Ambient Temperature
not exceed ±1.0% of span) supply, average steady state Effect: <±0.025% of
Stability: Not to degrade from consumption* of 4.7SCFH span/°C, maximum from
stated accuracy for six months (min 4.2SCFH@ 3psig, max -20°C to 80°C;
Step Response: <0.2 5.2SCFH@15psig); <±0.1% of span/°C,
seconds into 100ml load 40psig supply, max 9SCFH maximum
(6 in3) from 10% to 90% of @15psig output; RFI/EMI Effect:
span; Not guaranteed below 40psig supply, max 10SCFH <±0.25% of span change at
3psig output @30psig output in field strengths of 10V/m@
Supply Pressure Effect: Natural Gas Consumption frequencies of 20-1000MHz
Negligible from 20-40psig, (Dead-ended): Vibration Effect: Meets
steady pressure At 3-15psig output 20psig ANSI/ISA-75 13.01-1996
Air Capacity: supply, average steady state (R2007) 5.3.5 as follows:
5.0SCFM minimum (20psig consumption* of 5.7SCFH, 5-15Hz, 2mm peak-to-peak;
supply, 0psig output) (min 5.1SCFH@ 3psig, max 15-150Hz, 1g;
Relief Capacity: 2.5SCFM 6.2SCFH@15psig); 150-2000Hz, 0.5g
minimum (15psig output) 17psig supply, max 5.9SCFH Relative Humidity:
Air Supply: Instrument air @15psig output; 0-100%, non-condensing
only, 20-40psig 40psig supply, max 12SCFH
Gas Supply with -NG1 or @30psig output; Adjustment Zero & Span: Screw adjusts
-NG2 Option: 17-40psig. Mounting Position Effect: zero or span by ±10%
Same cleanliness as Negligible, unit can be mounted minimum, non-interactive
instrument air. H2S not to in any position; refer to user
exceed 20ppm manual for special conditions of Weight IPH2: 1.14kg (2.5 lbs)
Maximum Input: 80psig use with natural gas supply or IPX2: 2.4kg (5.3 lbs)
without damage for units with outdoor environments.
output pressure rating of
>15psig; 45psig without
damage for units with output
*Average flow rate determined at 9 psig output
pressure rating of ≤ 15psig
1/4 NPT
FEMALE
76mm PNEUMATIC
(3.0 in) 163mm INPUT 51mm 25mm
(6.4 in) PORT (2.0 in) (1.0 in)
33mm 69mm
(1.3 in) 16mm
1/4 NPT (2.7 in)
(0.65 in)
PNEUMATIC 99mm
INPUT PORT (3.9 in) 83mm
1/4 NPT FEMALE
PNEUMATIC INPUT FOR OPTIONAL (3.3 in)
1/4 NPT FEMALE
PORT (UNUSED PORT –FR1 FILTER/
PNEUMATIC OUTPUT
IS PLUGGED) REGULATOR/
PORT (COVERED BY
GAUGE
OPTIONAL –GA
OUTPUT GAUGE) 135mm
(5.3 in)
WITH –FR1 OPTION
72mm
(2.9 in DIA.)
MANUAL OVERRIDE
& FILTER HOLDER
76mm
(3.0 in)
REF. -P OPTION
2 INCH PIPE
MOUNTING
BRACKET
86mm
(3.4 in)
Ordering Information
IPH2
4-20MA 0-20PSIG 25PSI -FR1 Coalescing filter, miniature IPH ENCLOSURES:
2
Type 4X 4-12MA 1-17PSIG 22PSI supply line regulator and pressure WDNS Aluminum body with
Current-to- 12-20MA gauge that reads 0-60psig and PBT polyester cover; NPT
3-15PSIG 20PSI
Pressure into 0-4bars pneumatic and NPT electrical
Transmitter 250 ohms 3-16.6PSIG 22PSI -GA1 Output gauge (reads in entry ports
maximum 3-18PSIG 23PSI 0-30psig and 0-2bars WDNA Aluminum body
3-27PSIG 32PSI -VTD Standard Factory Calibration with aluminum cover; NPT
Custom
6-30PSIG 35PSI with NIST Test Data Report pneumatic and NPT electrical
ranges also
entry ports
available. .2-1BAR 1.4BAR
IPX2 ONLY: WDMS Aluminum body with
20-100KPA 140KPA PBT polyester cover; M20 x
.2-1KGCM2 1.4KGCM2 -NG1 IPX2 Type 4X unit equipped 1.5 metric, pneumatic and
.02-.10MPA .14MPA with electrical wire seal fitting electrical entry ports
assembly for using Natural Gas WDMA Aluminum body
Reverse Output†: (IPX2 only)
(sweet gas consisting of up to with aluminum cover; M20
20-0PSIG 25PSI 20ppm H2S) as the pneumatic x 1.5, pneumatic and metric
17-1PSIG 22PSI supply (not available with -FR1 and electrical entry ports
15-3PSIG 20PSI -GA1 options). Refer to Figure 4 for
IPX2
position.
Explosion- 16.6-3PSIG 22PSI IPX2 ENCLOSURES:
-NG2 IPX2 Type 4X unit equipped
Proof and Type 18-3PSIG 23PSI EXI Explosion-proof housing
with electrical wire seal fitting
3X* Current- assembly for using Natural Gas with ½-inch NPT, female
27-3PSIG 32PSI
to-Pressure (sweet gas consisting of up to threaded entry port for
Transmitter 30-6PSIG 35PSI connecting the input wiring
20ppm H2S) as the pneumatic
1-.2BAR 1.4BAR supply (not available with -FR1 and conduit
100-20KPA 140KPA -GA1 options). Refer to Figure 4 for EXIM* Explosion-proof
1-.2KGCM2 1.4KGCM2 position. housing with M20 x 1.5
-CAN cCSA approved for metric, female threaded entry
.10-.02MPA .14MPA
Intrinsically-Safe, Explosion Proof, port for connecting the input
* The unit’s output must match the supply
pressure to its right. Non-Incendive and General wiring conduit
**Supply Pressure is typically 5psi Locations. Includes warnings in NC** Replacement
(0.3bar) higher than output pressure. French and English. For Canadian electronics module without
†
On loss of mA input, the output will go to 0
PSI out. institutions only. enclosure
- ISA ANZEx approved Intrinsically
Safe and Type n * Not available with the -NG Option.
** Replacement or spare electronic
Note: The standard IPX2 tag includes approval modules must be ordered for specific
markings for Canada, Europe and US with output ranges (i.e. a 3-15PSIG
warnings in English only. electronics module cannot be field
calibrated for 6-30PSIG). Replacement
electronic modules are only available
for IPX2 units with S/Ns greater than
2321590.
P suffix indicates enclosure comes
*Type 4X for -NG1 equipped with base plate and U-bolts
for mounting on a 2-inch pipe (i.e.
and NG2 options EXIP).
When ordering, specify: Unit / Input / Output / Supply Pressure / Options [Housing]
Model number example: IPH2 / 4-20MA / 3-15PSIG / 20PSI / -FR1 [WDNA]
IPX2 / 4-20MA / .2-1BAR / 1.4BAR / -NG1 [EXI]
IPX2 / 4-20MA / .2-1BAR / 1.4BAR / -NG1 [NC]
Intrinsically-Safe
Ex ia IIC T4@85°C /T5@70°C
Environmental Protection:
IPH 2 Type 4X
IPX 2 (-Air), Type 3X & IP56
IPX 2 (-NG), Type 4X & IP66
Intrinsically-Safe
Class I, Divisions 1 & 2, Groups A, B, C & D
Class II, Divisions 1 & 2, Groups E, F & G
Class III, Divisions 1 & 2
Ex ia IIC; Zone 0, AEx ia IIC T4/T4A/T5
154mm
(6.1 in)
102mm
(4.0 in)
FRONT VIEW
(WITH -FR1 AND -GA1 OPTIONS)
BOTTOM VIEW
Instrument (NO OPTIONS)
Tag
117mm
(4.6 in)
-GA1 Option
Manual override &
filter holder
Pneumatic Pneumatic
input port output port
1/4 NPT 1/4 NPT
-FR1 Option female female
200mm
(7.9 in)
154mm
(6.1 in)
166mm
(6.5 in)
Manual override &
filter holder
117mm
(4.6 in)
Features:
■ 22 direct and reverse output ranges
■ Low air consumption and high output volume
■ High accuracy and fast response
■ Immune to supply pressure variation
■ Clog-resistant design, clean start up
■ RFI/EMI protection
Features:
■ Polyetherimide thermoplastic housing designed to meet
NEMA 4X, IP55 requirements
■ High technology sensor is insensitive to shock
and vibration
■ RFI/EMI protection
Features:
■ Control Room and Field Mounting with a wide variety
of housings
■ Perform with exceptional accuracy (±0.2% of span)
even in unstable environments
■ Self-sealing pneumatic connection allows disconnection
with no air loss
Features:
■ Water tight, dust-tight, and resistant to corrosion
and chemicals
■ High-technology sensor allows the PIH to perform with
exceptional accuracy in unstable environments
■ RFI/EMI protection
■ Reverse Output Option
Page 8 Specifications and information subject to change without notice. Printed in the U.S.A.