Professional Documents
Culture Documents
Based on our industry expertise and experience, we recommend the following checklist for fiber testing to guide you through some
of the uncertainties. For more technical details, please use our Statement of Work (SOW) documents as general guidelines to help
you prepare RFQs or contractual specifications for testing fiber cabling installations.
□
Fiber Be Encircled An EF compliant source http://www.flukenetworks.com/blog/cabling-
Cabling Flux compliant puts just enough light into chronicles/encircled-flux-what-it-and-why-
the fiber and passes only should-you-care
links that are good.
□
Fiber Do not use a If a VCSEL has been used http://www.flukenetworks.com/knowledge-
Cabling VCSEL to for multimode testing, the base/certifiber-pro/vcsels-not-permitted-tia-
certify reference power will be or-iec-optical-loss-testing
multimode links between -3 dBm and -10
dBm, not -19 dBm to -25
dBm
□
Fiber Specify test ANSI/TIA-526-7-A http://www.flukenetworks.com/knowledge-
Cabling reference cords (Singlemode): 0.2 dB for a base/certifiber-pro/test-reference-cords-
reference grade to trcs-vs-patch-cords
reference grade connection
ANSI/TIA-526-14-C
(Multimode)
0.1 dB for a reference
grade to reference grade
connection
□
Fiber Specify No text specifically stating http://www.flukenetworks.com/knowledge-
Cabling negative losses a negative loss result is to base/certifiber-pro/negative-loss-reported-
are to be be classified as a FAIL certifiber-pro
retested
Consult the equipment
manual to determine the
sign of power loss
readings, as a reading of
the wrong sign is often an
indication of improper
setting of the reference
power level.
□
Fiber Specify bi- A mismatch in backscatter http://www.flukenetworks.com/blog/cabling-
Cabling directional between the test and chronicles/bi-direction-testing-otdr
averaging for installed fiber can cause a
OTDRs negative loss event and/or
a false failure.
Bi-directional averaging
resolves any mismatches
□
Fiber Agree on a OTDR loss event http://www.flukenetworks.com/knowledge-
Cabling reflectance limit measurements heavily rely base/optifiber/reflectance-and-optical-
for OTDR on good reflectance; Poor return-loss-orl-optifiber
testing reflectance can result in
optimistic / negative loss
readings errors when the
application runs
□
Fiber Specify a fiber If you want a 1 jumper (one
Cabling reference cord) reference, you must
setting method specify it in your test Demystify Test
specification. Methods.docx