Network communication unit

DL Series

OPEN FIELD
NETWORK UNIT

EtherCAT
DL-EC1A

PROFINET
DL-PN1

PROFIBUS DP
DL-PD1

EtherNet/IP TM
DL-EP1

DeviceNet TM
DL-DN1

CC-Link
DL-CL1

TCP/IP
DL-EN1

RS-232C
DL-RS1A

BCD
DL-RB1A
OPEN FIELD
NETWORK UNIT
TECHNOLOGY TO CHANGE
THE FACE OF FACTORY AUTOMATION
DL supports communication with open field networks.

IG Series
GT2/GT Series
Multi-Purpose CCD Laser Micrometer
Contact Sensor

IB Series
Thrubeam Type
Laser Detection
Sensor

PLC

DL-EC1A
EtherCAT
IL Series
CMOS Multi-function
Analogue Laser Sensor

EtherCAT PROFINET PROFIBUS DP EtherNet/IP TM

DL-EC1A DL-PN1 DL-PD1 DL-EP1


MERIT 1 SAVE WIRING TIME WITH OPEN FIELD NETWORK

When more units are used in combination with each other, more wiring is required.
If communicating with the DL Series, only two wires are required to supply power to the sensor.

CONVENTIONAL WITH THE DL SERIES

Multiple preparation and wiring steps increased No need to trim the cables Terminal block unnecessary
the installation time. No additional wiring when replacing/adding sensors
Only a single communication cable is required between the PC/PLC and the DL Series for wiring.

MERIT 2 IMPROVING FUNCTIONALITY THROUGH REMOTE ACCESS WITH FIELD NETWORK

Judgment result monitoring, measurement value readout, input & output control and setting changes
can be done via HMI, PLC or PC.

CONVENTIONAL WITH THE DL SERIES

MONITORING MONITORING
To check the sensor status, the operator must directly check The sensor status can be monitored on an HMI, PLC or PC. Makes it easier to detect problems before
the sensor amplifier. an error occurs.

CHANGE SETTINGS CHANGE SETTINGS


Settings must be changed on every single sensor amplifier. The settings can be changed externally from an HMI, PLC or PC. Changeover times can be reduced.

DeviceNet TM CC-Link TCP/IP RS-232C BCD

DL-DN1 DL-CL1 DL-EN1 DL-RS1A DL-RB1A

EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
SPECIFICATIONS

EtherCAT Network communication unit DL-EC1A DeviceNet TM communication unit DL-DN1


Model DL-EC1A Model DL-DN1
Process data object communication (cyclic communication) Compatible functions Input/Output communication (poll)/ Explicit Message Communication
EtherCAT Compatible functions
Mailbox communication (message communication) CoE compatible Address Settings 0 to 63 (PGM compatible)
Specifications
Conformance test Complies with V2.0.42 Communication speed
DeviceNet TM (Automatic switching 500 kbps 250 kbps 125 kbps
PROFINET Network communication unit DL-PN1 Specifications method)
100 m (thick cable) 250 m (thick cable) 500 m (thick cable)
Model DL-PN1 Maximum cable length
100 m (thin cable) 100 m (thin cable) 100 m (thin cable)
Data I/O Communication Network power source 11 to 25 VDC (DeviceNet provided from the communication power source)
TM

Device type
Record data Communication
Number of connections 1 CC-Link Network communication unit DL-CL1
PROFINET Update time 2 to 512 ms
Model DL-CL1
specifications GSDML Version Ver. 2.3
Compatible versions Ver. 2.00 / Ver. 1.10 (selectable)
Conformance class Conformance Class A
Ver. 2.00: 1 station, 8× / 2 stations, 8× / 4 stations, 2×;
Conformance test V2.2.4
Number of occupied stations (selectable)
Compliant protocol LLDP, DCP CC-Link Ver. 1.10: 1 / 2 / 4 stations (selectable)
specifications Type of station Remote device station
PROFIBUS DP Network communication unit DL-PD1 Transmission rate 156 kbps / 625 kbps / 2.5 Mbps / 5 Mbps / 10 Mbps
Model DL-PD1 Setting of station numbers 1 to 64
Device type DP-V1 Slave (D-sub 9 pin, Number of the ports: 1)
Communication speed 9.6 kbps to 12 Mbps TCP/IP Network communication unit DL-EN1
PROFIBUS DP
specifications 9.6 / 19.2 / 45.45 / 93.75 kbps : 1200 m Model DL-EN1
Cable length 187.5 kbps : 1000 m, 500 kbps : 400 m
1.5 Mbps : 200 m, 3 / 6 / 12 Mbps : 100 m Transmission rate 100Mbps (100BASE-TX)
Ethernet STP cable or Category 5 or higher UTP cable
Transmission medium
Specifications (100BASE-TX)
EtherNet/IP TM Network communication unit DL-EP1 Maximum cable length 100 m (Distance between DL-EN1 and Ethernet switch)
Performance Socket communication,
Model DL-EP1 TCP socket 1
specifications no-protocol commands, ASCII
Cyclic Communication
Compatible Functions Message communication (Explicit messaging)
Compatible with UCMM and Class 3 RS-232C Network communication unit DL-RS1A
EtherNet/IP TM Number of connections 64
Model DL-RS1A
Specifications RPI (Transmission cycle) 0.5 to 10000 ms (0.5 ms unit)
Communication Method Full duplex
Tolerable communication bandwidth for
6000 pps Synchronization Method Start-stop
cyclic communication RS-232C
Conformance Test Compatible with Version A7 Specifications Transmission Code ASCII
Baud rate 2400/4800/9600/19200/38400 bps

BCD Network communication unit DL-RB1A


DIMENSIONS Unit : mm
Model DL-RB1A

DL-EC1A DL-PD1 Input/Output Terminal 34 pin connector (MIL Standard)


BCD Output: 4 (1 column) × 6 columns,
signal output, strobe output, alarm output
29.4

29.4 Control Output NPN Open collector 40 V, 20 mA or less,


BCD Output
Specifications residual voltage 1 V or less
Positive logic / Negative logic can be switched
15.8 22.2 57.4 ID Selection Input: 4, data request input
When cover open, maximum of 58.3

ma Control Input Non-voltage input, input time 2 ms or more,


x.
short circuit current 1 mA
When cover open,

10
maximum of 73.6

max.170° 5°
1.9
1.8
(39.0)

38.1
34.6

(38.5) 34.1
(0.2)

43.5 35.4
43.5 35.4 (0.2) 94.5
94.5
When cover open, maximum of 142.7

DL-PN1/EP1/EN1 DL-DN1 DL-RS1A DL-CL1 DL-RB1A


25.6

22.5 22.5
29.4 29.4 29.4
When cover open, maximum of 58.3

When cover open, maximum of 58.3

35.5 35.5
49.5 49.5
(48.2) 37.2 53.4
Max.125° 43.8 Max.125°
2.4 2.4 (57.8) 37.1

56.3 21.1 35.4 56.4


38.1 37.7 37.7
70 21.1 35.4
(42.5) (42.2) (42.2) 70

24.1 35.4 24.1 35.4


43.5 35.4 78.2 78.2
94.5

www.keyence.com

Copyright (c) 2016 KEYENCE CORPORATION. All rights reserved. DL-WW-C4-GB 1048-4 600K15