This document contains a fire/life safety checklist for inspecting a kitchen or restaurant facility. The checklist covers various areas including facility design and construction, means of egress, fire safety plans and employee training, housekeeping, fire prevention and protection systems, hazardous equipment and materials, commercial cooking equipment, and electrical systems. The purpose is to ensure the facility is in compliance with relevant building and fire codes and safety standards to prevent fire hazards and allow safe evacuation in an emergency.
This document contains a fire/life safety checklist for inspecting a kitchen or restaurant facility. The checklist covers various areas including facility design and construction, means of egress, fire safety plans and employee training, housekeeping, fire prevention and protection systems, hazardous equipment and materials, commercial cooking equipment, and electrical systems. The purpose is to ensure the facility is in compliance with relevant building and fire codes and safety standards to prevent fire hazards and allow safe evacuation in an emergency.
This document contains a fire/life safety checklist for inspecting a kitchen or restaurant facility. The checklist covers various areas including facility design and construction, means of egress, fire safety plans and employee training, housekeeping, fire prevention and protection systems, hazardous equipment and materials, commercial cooking equipment, and electrical systems. The purpose is to ensure the facility is in compliance with relevant building and fire codes and safety standards to prevent fire hazards and allow safe evacuation in an emergency.
Inspected By: Department: INSPECTION ITEMS Y N Comment A. Facility Design and Construction 1.0 Is the facility in compliance with the building and fire codes? 2.0 Have any renovations and/or alterations been made since the last inspection? 3.0 Are concealed spaces properly fire stopped, or otherwise protected? 4.0 Are cooking areas separated from all other spaces by firewalls or fire barriers? 5.0 Are the building’s furnishings and decorations fire retardant? 6.0 Are all exterior areas of the business property illuminated? 7.0 Are exterior doors and windows of the business property secured from unauthorized access? B. Means of Egress and Access 1.0 Are fire exits designed on the occupant loading and hazards? (e.g. number of fire exits to occupants) 2.0 Are fire exits/doors provided with panic hardware and not locked, such as by chains or padlocks? Are the hardware operates properly 3.0 Are the locations of fire exits indicated by clearly visible signs? 4.0 Is an emergency lighting system provided in means of egress? Is it functional? 5.0 Are access aisles in areas with seating at tables, in which there are a maximum of 50 patrons, at least 36 in (91cm) wide? 6.0 Are access aisles in areas with seating at tables, in which there are 50 or more patrons, at least 44 in (112 cm) wide? 7.0 Are access aisles in seating areas without tables, such as bar-side seating, at least 12 in (30 cm) wide for every 14 seats served by the access? 8.0 Is the travel distance to a fire exit or a separate smoke compartment not more than 200 ft. (61 m), or 250 ft. (76 m) for areas protected by an automatic sprinkler system? 9.0 No obstruction on exit doors 10.0 No exits, aisles, corridor or stairways obstructed
C. Fire Safety & Displayed Evacuation Plans
1 Emergency Evacuation Plan displayed? 2 Employees are trained in Basic firefighting safety 3 Employees are completed the emergency evacuation familiarization 4 Employees knows their nearest exit and assembly area 5 Chefs and Stewards are completed the LPG Training D. Housekeeping 1 All areas free from combustible waste material creating a fire hazard 2 Combustible materials kept clear of ignition sources 3 Sprinkler Head unobstructed, 18inches free clearance 4 All compressed gasses should be properly used, stored and secured E. Fire Prevention/Fire Protection 1 Fire alarm system inspected, tested and maintained (NFPA 72) 2 Type and quantity of Fire detection system on the area. 3 Sprinkler System (Water) inspected, tested and maintained (NFPA 25) 4 Available Fire hose Cabinet and distance from the area 5 Fire extinguisher visually inspected monthly/tested annually (NFPA 10) 6 Fire Extinguisher available, visible and unobstructed (NFPA 10) 7 “No Smoking” sign posted (E.O 28) 8 Self-Closing fire doors function properly and are free of obstruction 10 Distance of fire extinguisher between each other F. Hazardous Equipment/Materials 1 Material Safety Data readily available on premises for all hazardous materials 2 Inspection of: 2.1LPG line 2.2Gas Detector 2.3Gas Panel 2.4 kitchen fire suppression 2.5 Electrical Panel G. Commercial Cooking
Is kitchen equipment inspected on a regular basis?
(i.e., quarterly for high-volume cooking operations, semi-annually for moderate-volume cooking operations, and annually for low-volume cooking operations.) H. Electrical