ELECTRICAL SPECIFICATIONS

ET-P660255WW ET-P660250WW ET-P660245WW ET-P660240WW


Model Type
ET-P660255WB ET-P660250WB ET-P660245WB ET-P660240WB
Peak Power (Pmax) 255W 250W 245W 240W
Module Efficiency 15.67% 15.37% 15.06% 14.75%
Maximum Power Voltage (Vmp) 30.91 30.34V 30.14V 29.96V
Maximum Power Current (Imp) 8.25A 8.24A 8.13A 8.02A
Open Circuit Voltage (Voc) 37.54V 37.47V 37.2V 37.17V
Short Circuit Current (Isc) 8.82A 8.76A 8.73A 8.58A
Power Tolerance -
+3% 0 to +5W 0 to +5W 0 to +5W
Maximum System Voltage DC 1000V
Nominal Operating Cell Temperature 45.3±2℃
Series Fuse Rating (A) 20A

MECHANICAL SPECIFICATIONS PHYSICAL CHARACTERISTICS Unit:mm (inch)

Cell type 156mm x 156mm


Number of cells 60 cells in series 50

45°
Weight 18.8 kg (41.45 lbs)
8

50

-3
40 (1.57)

0'
0
1640×992×40 mm
Dimensions
(64.57×39.06×1.57 inch) Junction box

Max Load 5400Pascals ( 112 lb/ft2)

8-14×9

1050(41.34)
TEMPERATURE COEFFICIENT
(0.55×0.35)

1360(53.54)
1640(64.57)
1640(64.57)

860(33.86)
Temp. Coeff. of Isc (TK Isc) 0.04 %/℃
Temp. Coeff. of Voc (TK Voc) -0.34 %/℃ 4-φ4

Temp. Coeff. of Pmax (TK Pmax) -0.44 %/℃ cable(-) cable(+)


35(1.38)

PACKING MANNER
17.5(0.69)

10(0.39)
Container 20’ GP 40’ GP 40’ HQ
Pieces per Pallet 26 26 26
Pieces per Container 312 728 784 954(37.56)
992(39.06)
992(39.06)

ELECTRICAL CHARACTERISTICS
Current-Voltage & Power-Voltage Curve Temperature Dependence of Isc, Irradiance Dependence of Isc,
(AM1.5,Cell Temperature 25℃) Voc and Pmax Voc and Pmax (Cell Temperature:25℃)

10 300 120 100


Voc
245.4
Normalize Isc,Voc and Pmax(%)

Normalize Isc,Voc and Pmax(%)

Isc
100
8
80
240
198.0
80 Voc
Current(A)

Power(W)

60
6 180 Pmax
60
148.3
40
4 120
40
Temp.Coeff.of Isc =+0.04%/℃ Isc
98.0 Pmax
Temp.Coeff.of Voc =-0.34%/℃ 20
2 60 20 Temp.Coeff.of Pmax=-0.44%/℃
47.3
0 0 0
0 5 10 15 20 25 30 35 40 -25 0 25 50 75 100 0 200 400 600 800 1000

Voltage(V) Cell Temperature (℃) Irradiance (W/m2 )

1000 W/m2 800 W/m2 600 W/m2 400 W/m2 200 W/m2

Note: the specifications are obtained under the Standard Test Conditions (STCs): 1000 W/m2 solar irradiance, 1.5 Air Mass, and cell temperature of 25 C.
o

2
The NOCT is obtained under the Test Conditions : 800 W/m , 20°C ambient temperature, 1 m/s wind speed, AM 1.5 spectrum.