You are on page 1of 5

Incremental encoders - combination

HOG 10 + FSL
Encoder with integrated centrifugal switch
Blind hollow shaft or cone shaft / 300…5000 pulses per revolution

Overview
■ TTL output driver for cable length up to 550 m
■ Mechanical speed monitoring based on centrifugal force
■ Hybrid bearing for extended service life
■ Terminal boxes, turn by 180°

Technical data
Technical data - electrical ratings Technical data - electrical ratings (centrifugal switch)
Shaft insulation Suitable up to 2.8 kV Minimum switching current 50 mA
Transmission length ≤350 m at 100 kHz (HTL-P) Technical data - mechanical design
≤550 m at 100 kHz (TTL) Size (flange) ø105 mm
Interference immunity EN 61000-6-2 Shaft type ø16...20 mm (blind hollow shaft)

The product features and technical data specified do not express or imply any warranty. Technical modifications subject to change.
Emitted interference EN 61000-6-3 ø17 mm (cone shaft 1:10)
Approval CE Admitted shaft load ≤450 N axial
Technical data - electrical ratings (encoder) ≤600 N radial
Voltage supply 9...30 VDC; 5 VDC ±5 % Protection EN 60529 IP 66
Consumption w/o load ≤100 mA Speed (n) ≤1.25 · ns
Pulses per revolution 300 … 5000 Range of switching speed 850...4500 rpm (Δn = 2 rpm/s)
(ns)
Phase shift 90 ° ±20°
Operating torque typ. 6 Ncm
Duty cycle 40…60 %
Rotor moment of inertia 400 gcm²
Reference signal Zero pulse, width 90°
Material Housing: aluminium die-cast
Output frequency ≤120 kHz
Shaft: stainless steel
≤300 kHz (on request)
Operating temperature -40...+100 °C
Output signals K1, K2, K0 + inverted
-25...+100 °C (>3072 pulses)
Error output (option EMS)
-50...+100 °C (optional)
Output stages HTL-P (power linedriver)
Resistance IEC 60068-2-6
TTL/RS422
Vibration 5 g, 10-2000 Hz
Sensing method Optical IEC 60068-2-27
Technical data - electrical ratings (centrifugal switch) Shock 50 g, 11 ms
Switching accuracy ± 4 % (Δn = 2 rpm/s); Corrosion protection IEC 60068-2-52 Salt mist
20 % (Δn = 1500 rpm/s) for ambient conditions C4 according to
Switching deviation ≤3 % (cw-ccw rotation) ISO 12944-2
Switching hysteresis 40 % of switching speed Connection 2x terminal box
3x terminal box (with option M)
Switching outputs 1 output, speed control
Weight approx. 2.2 kg
Output switching capacity ≤6 A / 230 VAC; ≤1 A / 125 VDC
2.4 kg (with option M)
(EAC: <50 VAC / 75 VDC)

Optional
■ Function control with EMS (Enhanced Monitoring System)
■ Redundant sensing with two terminal boxes
■ With heating up to -50°C
2021-11-02

www.baumer.com Data sheet – HOG 10 + FSL Page 1 of 5


Incremental encoders - combination

HOG 10 + FSL
Encoder with integrated centrifugal switch
Blind hollow shaft or cone shaft / 300…5000 pulses per revolution

General information Terminal significance


The constructive design of the centrifugal switch is its use as a switch Encoder incremental
with positive break function. It must not be used as a continuous switch
+UB Voltage supply
(switching cycles greater than 500 during service life).
0V ( ) Ground

Terminal assignment Earth ground (housing)


K1 Output signal channel 1
View A (see dimension)
Connecting terminal terminal box encoder K1 Output signal channel 1 inverted
K2 Output signal channel 2 (offset by 90° to channel 1)
K2 Output signal channel 2 inverted
K0 K0 Zero pulse (reference signal)
K0 K0 Zero pulse inverted
K2 Err Error output (option EMS)
K2 dnu Do not use
K1
K1
Output signals
0V( )
+UB HTL/TTL
At positive rotating direction (see dimension)

K1
Option EMS: View A (see dimension)
Connecting terminal terminal box encoder K1

K2
dnu
0V( ) @Err

The product features and technical data specified do not express or imply any warranty. Technical modifications subject to change.
Err K2
K0 K0

K2 K2
K0 90°
K1 K1
0V( )
+UB
K0

Option EMS: Status LED / error output


Flash light red* Error of signal sequenze, zero pulse
View B (see dimension) or pulses
Connecting terminal centrifugal switch (Error output = HIGH-LOW alternation)
Red Overload output transistors
(Error output = LOW)

A Flash light green Device o.k., rotating


(Error output = HIGH)
3 4 Green Device o.k., stopped
(Error output = HIGH)
1 2 No light No voltage supply connection or wrong
1 2 3 4
B connection
(Error output = LOW)
* Only at rotating device
A = make contact, B = break contact
2021-11-02

www.baumer.com Data sheet – HOG 10 + FSL Page 2 of 5


Incremental encoders - combination

HOG 10 + FSL
Encoder with integrated centrifugal switch
Blind hollow shaft or cone shaft / 300…5000 pulses per revolution

Dimensions
14.6 Positive rotating direction
Drawing 90° rotated 105.5
±9 ød L1 L2
°
Option 16 53 65.5 79.5 98.5
HOG 10 20 35 51.5 69.5
(HOG 10.2) 2
27+0.5 1
2 FSL
ø10.5

R1
0 A
ø105 A
ø86.5
ødH7

M8
ø50

(B)

Option M
(redundant)

Pull-off
thread
M20x1.5

~R
ø6.5
L1

115
M20x1.5 ±15°
L2 13

149

Accessory

1 Status LED (option EMS)


2 Status LED (option M (redundant) and EMS)

The product features and technical data specified do not express or imply any warranty. Technical modifications subject to change.
Blind hollow shaft

14.6 Positive rotating direction


105.5
±9 Drawing 90° rotated
° 79.5 98.5
Option
69.5
HOG 10
(HOG 10.2) 2
26 1
2 FSL
ø10.5

R1
0 A
ø17JS8

A
ø86.5
ø105
ø50

1:10 (B)
M8

Option M
(redundant)

20 M20x1.5
~R
ø6.5

115

22.5 M20x1.5 ±15°


13
37.5 Pull-off thread

147.5
Accessory

1 Status LED (option EMS)


2 Status LED (option M (redundant) and EMS)

Cone shaft
2021-11-02

www.baumer.com Data sheet – HOG 10 + FSL Page 3 of 5


Incremental encoders - combination

HOG 10 + FSL
Encoder with integrated centrifugal switch
Blind hollow shaft or cone shaft / 300…5000 pulses per revolution

Ordering reference
HOG10 ## # DN #### ### ## ###### + FSL #####
Product
Incremental encoder + Centrifugal switch HOG10
EMS - Enhanced Monitoring System
Without EMS
With EMS .2
Redundant sensing
Without redundant sensing
With redundant sensing M
Output signals
K1, K2, K0 DN
Pulse number(1)
300 300
500 500
512 512
1000 1000
1024 1024
1200 1200
2048 2048
2500 2500
3072 3072
4096 4096
5000 5000

The product features and technical data specified do not express or imply any warranty. Technical modifications subject to change.
Voltage supply / output stage
9...30 VDC / output stage HTL with inverted signals I
5 VDC / output stage TTL with inverted signals TTL
9...30 VDC / output stage TTL with inverted signals R
Sealing system
Dust protection LR
Damp protection SR
Shaft diameter
Blind hollow shaft ø16 mm 16H7
Blind hollow shaft ø20 mm 20H7
Cone shaft ø17 mm (1:10) 17K
Version speed switch
Mechanical centrifugal switch + FSL
Switching speed (ns)
850...949 rpm (Δn = 2 rpm/s)(2) 6 ...
950...1099 rpm (Δn = 2 rpm/s)(2) 5 ...
1100...1299 rpm (Δn = 2 rpm/s)(2) 4 ...
1300...1799 rpm (Δn = 2 rpm/s)(2) 3 ...
1800...2499 rpm (Δn = 2 rpm/s)(2) 2 ...
2500...4500 rpm (Δn = 2 rpm/s)(2) 1 ...

(1) Other pulse numbers on request.


(2) Please specify the exact switching speed in addition to the part number (factory setting).
2021-11-02

www.baumer.com Data sheet – HOG 10 + FSL Page 4 of 5


Incremental encoders - combination

HOG 10 + FSL
Encoder with integrated centrifugal switch
Blind hollow shaft or cone shaft / 300…5000 pulses per revolution

Accessories
Mounting accessories
11077197 Mounting kit for torque arm size M6 and earthing
strap
11077087 Mounting and dismounting set
11043628 Torque arm M6, length 67...70 mm
11004078 Torque arm M6, length 120...130 mm (≥71 mm)
11002915 Torque arm M6, length 425...460 mm (≥131 mm)
11054917 Torque arm M6 insulated, length 67...70 mm
11072795 Torque arm M6 insulated, length 120...130 mm (≥71
mm)
11082677 Torque arm M6 insulated, length 425...460 mm (≥131
mm)

Connectors and cables


Sensor cable for encoders HEK 8

Diagnostic accessories
11075858 Analyzer for encoders HENQ 1100
11075880 Analyzer for encoders HENQ 1100 B

The product features and technical data specified do not express or imply any warranty. Technical modifications subject to change.
2021-11-02

www.baumer.com Data sheet – HOG 10 + FSL Page 5 of 5

You might also like