LEVEL TRANSMITTERS

ULTRASONIC INTEGRATED LEVEL TRANSMITTERS FOR LIQUIDS EasyTREK

TECHNICAL DATA

EasyTREK
level transmitters
for liquids

4-wire version – SC–38 – SC–36 SC–34 –

2-wire version SP–39 SP–38 SP–37 SP–36 SP–34 SP–32

Range 0.2…4 m* 0.25…6 m* 0.35…8 m* 0.35…10 m* 0.45…15 m* 0.6…25 m*

Total beam angle 6° 5° 7° 5° 5° 5°

Ambient temperature SP: –30 °C … +80 °C ; SC: –30 °C … +60 °C


Process pressure
0,03 … 0,3 MPa (0,3 … 3 bar)
(absolute)
Process connection 1” or 1 1/2” BSP / NPT 1” or 2 ” BSP / NPT 1” or 2” BSP / NPT 1” BSP 1” BSP 1” BSP

Applied materials PP or PVDF housing, EPDM cable sealing, PVC cable isolation

Accuracy * ± (0.2 % of measured distance +0.05 % of range)


Resolution
<2 m: 1 mm 2 … 5 m: 2 mm 5 … 10 m: 5 mm >10m: 10 mm
(dep. on distance)
Ingress protection IP 68

Ex marking ATEX II 1 G EEx ia II B T6 (available for 2-wire SP series only!)


2-wire Standard: 4-20 mA +HART, max. 600 ohm, Relay (SPDT, 30 V DC, 1 A DC)
Outputs
4-wire Standard: 4–20 mA +HART, max. 600 ohm, Relay (SPST), Option: HART, RS485 [instead of 4–20 mA]

2-wire 12 ... 36 V DC / 44 ... 800 mW


Power supply
4-wire 11.4 ... 40 V DC / 3.6 W 11.4 ... 28 V AC / 4 VA
2
Connecting 2-wire LIYCY type 2 x 0.5 mm shielded cable, Ø 6 mm ; standard length 5 m (can be ordered max. 30 m)
cable 4-wire LIYCY type 6 x 0.5 mm2 shielded cable, Ø 7.5 mm ; standard length 3 m (can be ordered max. 30 m)

* Under optimal circumstances of reflection and stabilised transducer temperature

SAT-304 HART modem

MultiCONT SCA-360-2 SPA-340-4

72
LEVEL TRANSMITTERS

ULTRASONIC INTEGRATED LEVEL TRANSMITTERS FOR LIQUIDS EasyTREK


EasyTREK SC-38/36/34 - 4-wire versions
Integrated compact ultrasonic level transmitters with process current / HART and control relay
output for liquids
1" BSP
SenSonic transducer technology, QUEST+ advanced, process adaptive signal processing,

22
secondary lightning protection, fully temperature compensated

16
Transducer and enclosure material PP with IP68; 5 m integrated cable

BSP:15,NPT:22
Power supply: 11.4-40 V DC and 11.4-28 V AC
Programming

199
With supplied magnet: assignment of 4 and 20 mA as well as relay switching point to levels, 96

error indication and damping time


Full feature programming: standard with flow metering, 32-point linearisation, application 2" BSP or NPT

60
optimisation, fixed target supression, etc. with HART modem and the EView software or
with the MultiCONT controller. The EView light software (on DVD) is provided free of charge.
EasyTREK SC_-38
Type
SC X ─ 3 X ─X
8 0.25-6 m (80 kHz) 1“ and 2” mounting
6 0.35-10 m (60 kHz)
1" BSP
4 0.45-15 m (40 kHz)

22
Transducer material

16
SC ─ 3 X X ─ X
A PP

162
B PVDF

Mounting
SC X ─ 3 X ─ X
96
0 BSP thread
N 2" NPT and 1” BSP (Only for SC-38) EasyTREK SC_-36

Output
SC X ─ 3 X X ─
2 4-20 mA + Relay
1" BSP
4 4-20 mA + HART + Relay

22
16
SC ─3 ─

173
Cable
Maximum length 30 m; each started 1 m over the standard 5 m

122

Accessories to order EasyTREK SC_-34


Type
S A A - 1 1 0 Transparent pipe connector
S F A - Flanges (See "Mounting accessories")
S A S - 3 0 2 EView software package (See "Electronic accessories")
S A T - 3 0 4 HART-USB modem (See "Electronic accessories")
S AK - 3 0 5 - 2 HART-USB/RS485 modem
S A A - 1 0 1 Fast connecting gland for pipe mounting devices with 1”
process connection
S A A - 1 0 6 Damping gland for mounting SC and SP devices to thin metal
roofs
S A A - 1 0 7 - 0 200 mm mounting bracket (Paint coated steel)
S A A - 1 0 8 - 0 500 mm mounting bracket (Paint coated steel)
S A A - 1 0 9 - 0 700 mm mounting bracket (Paint coated steel)

NIV24
EasyTREK SCA-380
EasyTREK SCA-360
SAT-304

73