New Cooling of Seal
New Cooling of Seal
by
Lyndon Scott Stephens
Associate Professor
Matthew A. Hayden
Graduate Research Fellow
and
Daryl S. Schneider
Research Assistant
University of Kentucky, Bearings and Seals Laboratory
Department of Mechanical Engineering
Lexington, Kentucky
( )
Figure 1. Conventional Mechanical Seal with External Flush.
6 as Ts1, Ts2, Tr1, and Tr2 for the stationary and rotating rings,
Electroplated Tungsten
Nickel Cover Plate Carbide Coating respectively. A slip ring arrangement is used for the rotating ring
thermocouple measurements. In addition to the temperature meas-
urements the thrust washer tribometer records friction torque,
speed, and applied load as well as the flowrate of the coolant
during testing. This experimental apparatus and the procedures
used are detailed extensively in Johns (2003) and therefore not
discussed further.
SS Base
Figure 5. Seal Prototype.
Ring
IDs mm 22.4 40.3
LB mm 8.7 12.75
rotary is run against the WC carbide end face of the micro heat sink L1 mm 2.54 2.54
stationary ring. In all cases the coolant used in the micro heat sink Lhx Pm 600 856
is water supplied at ambient conditions and circulated from the Lc Pm 3400 3,000
outer ring diameter, across the heat sink and exiting at the inner Pm
Lr mm 17.0 22.4
(stepped)
L2 mm -- 0.89
L3 mm -- 0.76
L4 mm 2.54 --
used at the coolant inlet. Pressure gauges are mounted on the inlet thermal resistance. Considering the geometry in Table 1, the micro
and outlet cooling lines to measure pressure drop as the coolant heat sink is completely constructed within 2.6 radial face widths of
moves across the heat sink. the interface for the high PV dry running prototype and within 1.1
radial face widths for the ANSI pump seal prototype. The heat sink,
Discharge pressure, flow and
Retrofitted 3-piece seal
gland with stationary temperature gages/sensors therefore, has a high potential for controlling the temperature at the
ring and coolant Pump casing Suction pressure and seal interface, Tint.
temperature sensors temperature gages/sensors Given the close proximity of the heat sink to the interface it is
Cradle spacer
assumed that the dominant heat flow path is axially away from the
MHX coolant inlet lines (2)
interface. It is also assumed that the thermal contact resistance
Pump bearing housing between the two rings is negligible. Table 2 summarizes the
MHX coolant chiller thermal conductivity of the materials of construction and the
5.6 kW equipped with 3Pm resulting conductive thermal resistance of each layer that
(7.5 HP) filter, inlet and outlet
DC motor pressure and flow comprises the prototypes. Referring again to Figure 6, Rrot is the
Coolant
gages/sensors resistance between the interface and the thermocouples giving tem-
Chiller/
Filter
perature readings Tr1 and Tr2 in the rotating ring. Recall that these
Unit thermocouples are used only during the high PV, dry running tests.
MHX coolant return line Seal cooling flush line
The thermal resistances that comprise the stationary ring are that of
per API plan 11 the WC coating, Rwc, the heat sink cover plate, Rc, the total axial
equipped with pressure
and flow gages/sensors
thermal resistance of the pins, Rpins, and the resistance between the
F bottom of the heat sink and the thermocouples located in the
Figure 7. Schematic of Pump Testing Facility. stainless steel substrate, Rs, that gives temperature readings, Ts1
and Ts2.
Figure 8 shows a computer-aided design (CAD) drawing of the
three part gland plate design used to accommodate the stationary Table 2. Thermal Parameters at Test Conditions.
seal ring. Although there are several alternative gland and cartridge
seal designs, the one used in this work provides for the extensive High PV Dry ANSI
instrumentation required in this experiment. The special gland Property Symbol Running Pump Seal
plate distributes the coolant water in a uniform fashion to the heat Prototype Prototype
sink outer diameter. Once the coolant passes through the heat sink
it is collected and routed out of the pump and back to the chiller. Nickel kni 88.2 88.2
Conductivity
Together the chiller and the gland plate provide a closed coolant
(W/m-K)
coating
Heat Sink Rc 0.10 0.03
Cover
Rotating Ring
Heat Sink Pins Rpins 0.04 0.02
Substrate Rs 0.41 0.14
Coolant
Flowrate Q 1.4 LPM 5.0 LPM
Heat Sink Convection
300
• The overall thermal resistance between the interface and the Tint - 0 LPM
thermocouples in the rotary, which is Rrot = 1.12 W/K for the high
PV, dry running prototype; 250
Ts - 0 LPM
Temperature (degC)
200
micro heat sink coolant (when the coolant is flowing), Rhx, which Tr - 0 LPM
is the sum of Rwc, Rc, and Rcv and equals 0.33 W/K and 0.10 W/K
for the high PV and pump prototypes, respectively; and 150
• The overall thermal resistance between the interface and the 100 Tr - 1.4 LPM
thermocouples in the substrate (when the coolant is not flowing),
Rstat, which is 0.62 W/K and 0.21 W/K. Tint - 1.4 LPM
50 Ts - 1.4 LPM
The ability of the heat sink to control the temperature at the sealing ambient &
interface depends on the thermal resistance, Rhx. It is interesting to coolant
0
note that for the flowrates used in these experiments the convective
0:00:00 2:24:00 4:48:00 7:12:00 9:36:00
thermal resistance comprises a large portion of the overall thermal Time (hh:mm:ss)
resistance between the interface and the coolant (about 50 percent
for both the high PV tests and the ANSI pump tests). This is a) Temperature
reduced by increasing the coolant flowrate through the heat sink
and will result in a lower interface temperature, Tint, all else being
equal. This may also be reduced by optimizing the spacing of the 200
cooling pins. Further reductions in Tint are accomplished by 180
estimate of the actual value of Tint for this case is constructed by Figures 10c and 10d. Finally the heat carried away by the heat sink
using the stationary temperature, Ts, and the conductive thermal is computed directly from the measured data and presented in
resistances Rstat = 0.62 W/K and Rrot = 1.12 W/K between the Figures 10e and 10f.
interface and the thermocouples Ts and Tr, respectively. In this 60 115
Ti
model, any heating of the interface due to the slip ring ball bearings 55
Ti
To H
To Ts G
is neglected, which is consistent with a lower bound Tint. The 50 Ts 95
Tbx I
Tbx Tint
Temperature (degC)
resulting interface temperature is estimated as 271.4°C and shown
Temperature (degC)
45 A B F
Tint
75
in Figure 9a. Comparing the two interface temperatures indicates 40 C
D
E
35
that the heat sink cools the interface temperature dramatically by a 55
30
factor of at least 4.2, clearly demonstrating the benefit of the heat 25 35
sink to thermal performance. 20
15 15
ANSI Pump Experiments 0:00:00 0:14:24 0:28:48 0:43:12 0:57:36 1:12:00 0:57:36 1:04:48 1:12:00 1:19:12 1:26:24
Time (hh:mm:ss) Time (hh:mm:ss)
small ANSI pump. These tests evaluate seal performance with 40.0
Pump
20.0
Pump
respect to temperature, pressure drop across the heat sink, visible
Flowrate (LPM)
Coolant 15.0 Coolant
30.0
Flowrate (LPM)
leakage, and heat sink clogging. The specific conditions relevant to 20.0 10.0
this seal application are given in Table 3. The fluid being pumped 10.0 5.0
is water with a suction lift of about 3 feet and a basin temperature 0.0 0.0
0:57:36 1:04:48 1:12:00 1:19:12 1:26:24
of 18°C. The pump was operated at three different flowrates of 0 0:00:00 0:14:24 0:28:48 0:43:12
Time (hh:mm:ss)
0:57:36 1:12:00
Time (hh:mm:ss)
pressures and seal chamber pressures at these flowrates are given 140
1000
Seal
Seal (estimated)
in the table. The seal has a balance ratio 0.74 and a spring pressure 120 800 (estimated)
Heat (Watts)
100 Heat Sink
Heat (Watts)
600 Heat Sink &
of 203.1 kPa (29.2 psi). Assuming flat parallel face operation the 80 Gland
60 400
pressure gradient factor is k = 0.5, resulting in relatively low face 40
200
pressures in the range of 223 to 238 kPa. 20
0 0
0:00:00 0:14:24 0:28:48 0:43:12 0:57:36 1:12:00 0:57:36 1:04:48 1:12:00 1:19:12 1:26:24
Time (hh:mm:ss) Time (hh:mm:ss)
Table 3. Operating Conditions in a 3600 RPM ANSI Pump
e) f)
Application. F
p pplication Figure 10. 131.536 ANSI Pump Test Results. (Ti – coolant inlet,
Description Quantity To – coolant outlet, Ts – stationary ring [below heat sink], Tbx –
seal chamber fluid, Tint – interface [estimated].)
Pumpage Water @ 18 degC
Flowrate 0-38 LPM Also shown in Figures 10e and 10f is the estimated heat
0-10 GPM generated at the seal interface based on a friction coefficient of
Suction Pressure -26.3 kPa 0.07, which was measured during the dry running tests for this
(-3.8 psi)
Pump and Seal Conditions
material pair and is also the published value for WC versus carbon
Discharge 470.8-512.3 kPa in typical water applications. Note that for the moderate PV values
Pressure (68-74 psi)
of this application and the low friction coefficient of 0.07, the heat
Seal chamber 90-152.1 kPa
Pressure (13-22 psi)
generated at the seal is quite low at 60 W. This value is shown as
Balance Ratio 0.74
constant in the figure because it is not a directly measured variable.
Spring Pressure 202 kPa In reality, this value will change as the conditions at the seal
(29.2 psi) interface (e.g., coning) change with temperature. For the pump seal
Face Pressure 223-238 kPa tests the actual friction coefficient is less than 0.07 due to the added
(32.3-34.5 psi) lubrication of the sealed water. Therefore this is an upper bound
PV Value 1.87-2.00 MPa*m/s estimate of the heat generated at the seal interface. Note that there
(53,369-56,935 psi ft/min) are numerous heat generation mechanisms in the pump (bearings,
Heat Sink Water @ 18 degC viscous drag, etc.). Therefore the heat carried away by the heat sink
Coolant when the coolant is flowing is significantly greater than that
Hours @ generated at the seal interface. Finally, at each test condition an
Normal 45 estimate of the interface temperature, Tint, is given. In each case
Cumulative Run Time
coolant outlet, To, which is merely sitting in nonflowing water at temperature of the coolant at the heat sink and the thermal resist-
this point. The seal chamber fluid temperature, Tbx, increases but ance between the heat sink and the interface yields Tint in the range
is significantly less than Ts and To, as a certain amount of seal of 44 to 49°C for this transient condition. At condition “H” the
chamber fluid is replenished even at this low flow condition. At coolant flow is turned off and Ts, To, and Tbx dramatically increase
condition “C” coolant begins to flow at 5 lpm, cooling the station- to an excess of 95°C and still increasing. The interface temperature
ary ring to the temperature of the cooling fluid, about 18°C. Note during this part of the cycle is at least this high as well. During
that the temperature of the fluid at the heat sink outlet is only 0.2°C condition “I” the pump is turned off and the temperatures begin to
larger than the temperature at the inlet, indicating that the bulk decay to room temperature.
fluid temperature at the micro heat sink is about 18.2°C. Using the Table 3 summarizes the cumulative run time on this mechanical
fluid temperature measurements and the fluid flowrate the heat seal during the ANSI pump experiments. The pump spent 45 hours
carried away by the heat sink is computed as about 100 W over this under normal operation close to its BEP, 4.5 cumulative hours in
cycle. Note that in Figure 10e this heat varies between 60 to 120 the dead head condition, and 7 cumulative hours with the pump
W. This is partly due to the measurement uncertainty of the ther- running completely dry (no water in the pump at all). During these
mocouples (± 0.2°C) and the fact that the fluid delta T across the tests no visible leakage was observed from the prototype mechan-
heat sink is so small and partly due to transients in the system. Note ical seal.
that 120 W is greater than the heat generated at the interface of 60 Another performance indicator for the heat sink is the pressure
W, indicating that there is excess heat entering the heat sink due to drop from the inlet to the outlet. This was measured for three
the low efficiency of operating at only 19 lpm. Using 120 W as the flowrates and is presented in Figure 11. For the 5 lpm flowrate used
upper bound on heat coming from the interface, and the thermal in these experiments the pressure drop was found to be only 19.24
resistance between the heat sink and the interface, an upper bound kPa (2.8 psi). This amounts to a pumping power of only 1.6 W that
on Tint is computed as 28.2°C. Note that Ts is essentially the was used to carry away over 600 W of heat. A related performance
coolant temperature (18.5°C) indicating that all of the heat coming indicator is whether or not the pressure drop across the heat sink
down the shaft across the seal interface is carried away by the heat increased during testing. If so, this is an indication that the very
sink. This heat is also an upper bound on the heat crossing the seal small heat sink channels are clogging. This was monitored closely
interface during condition “B.” Again using Ts and the thermal during the 56.4 hours of testing and no clogging was observed.
resistance between Ts and the interface an estimate of the interface
temperature during condition “B” is 53.8°C. Comparing operating 25
conditions “B” and “C” illustrates that the heat sink successfully
carries away all of the heat around the seal, cools the stationary 19.24
20
ring to the temperature of the coolant, and reduces the interface
temperature from 35.3°C above the coolant temperature to only 'P (kPa) 15
9.7°C above the coolant temperature. 10.10
During conditions “D” and “E” the coolant flowrate is again shut 10
off but the pump flowrate remains at 19 lpm. Therefore these two
conditions are exactly the same as condition “B.” At condition “F” 5 3.47
the pump is dead headed to zero flow. In this condition the motor
power is converted into heat as the water being pumped has 0
nowhere to flow. As a consequence the overall temperature of the 3 4 5
pump increases dramatically and the heat generated at the interface
of the seal has a negligible effect on the bulk temperature at the Coolant Flow (LPM)
interface (hot spots notwithstanding). As Figure 10b indicates at Figure 11. Measured Pressure Drop Across Heat Sink.
this condition the temperature of the seal chamber fluid, Tbx, at the
coolant outlet, To, (again, there is no coolant flowing in this
condition so there is just stagnant water there) and in the stationary
DISCUSSION
ring, Ts, are approximately the same as the pump heats up to above The experimental results clearly demonstrate the benefit of the
75°C and is still increasing. In separate tests the pump was allowed heat sink seal ring to the thermal performance of the mechanical
to continue to operate in this condition until the pumped water seal. First, the heat sink seal prototype successfully functions as a
reached its boiling point at 100°C. Once this transition to steam mechanical seal as no visible leakage was observed over the 56.4
occurred the temperature leveled out at 110°C in the seal chamber hours of cumulative testing in the water application. Future work
and at the stationary ring. In this operating condition, Tint is essen- will need to consider gas phase leakage from the prototype.
tially the same as the surrounding temperatures since the heat Second, the heat sink clearly protects the seal against temperature
coming in from around the pump is so large (several kW from the induced failures due to errant operating conditions such as dry
5.6 kW motor) as compared to the seal heat being generated. running of the pump due to loss of fluid at the suction, and dead
At condition “G” the heat sink flow was turned on to 5 lpm. The heading of the pump when the discharge block valve is shut off. As
small thermal capacitance and resistance between the coolant and the results indicate, the temperature of the stationary ring was
the stationary ring are evident due to the rapid decay of Ts from cooled from 230.4°C for the high PV dry running case and >95°C
75°C to 20.5°C, which is just 2.0°C above the coolant temperature. for the dead head case to the temperature of the heat sink coolant
This dramatic reduction in stationary ring temperature demon- for both of these high heat load cases. As a secondary benefit, these
strates the potential of the heat sink to protect the stationary ring results also illustrate that the heat sink seal could be used in hot
and its associated elastomers from high temperature processes applications to protect elastomer O-rings if used. Note that future
where large heat flows impact seal reliability. Figure 10f indicates work will consider the effect of wear debris on seal performance
that the heat being carried away by the cooling system is approxi- for extended dry running conditions. Third, the heat sink is
mately 700 W (1 hp). Note that this heat is not only flowing to the effective in increasing the product temperature margin as it signif-
coolant at the heat sink but also from the gland plate to the coolant icantly cools the seal interface and slightly cools the seal chamber.
as it passes through the gland plate and toward the heat sink region. This is particularly relevant in sealing light hydrocarbons, which
This is substantiated by the temperature measurement at the may have PTMs less than 2 to 4°C.
outside of the gland indicating it was at 53.1°C. An estimate of Tint Of particular interest for low PTM applications is that the heat
during this condition is based on one-half of the heat being trans- sink is distributed across the entire end face of the seal. As was
mitted to the coolant at the heat sink. Again, using the bulk seen in the experiments, the cooling water increased only 2 to 3°C
A NEW CONCEPT IN MECHANICAL SEAL COOLING—THE INTEGRAL HEAT SINK 125
between the heat sink inlet and outlet indicating that the end face CONCLUSIONS
is cooled very uniformly from the OD to the ID. This indicates that
This paper presented the first experimental results for a new
the hot spot at the seal inner diameter that is associated with con-
concept in mechanical seal cooling: the integral heat sink. From
ventional single seal designs is significantly reduced if not
these results it is concluded that the integral heat sink design can
eliminated. Note that the ability of the heat sink to cool the seal
perform successfully as an end face mechanical seal and that it is
chamber is limited by the convective thermal resistance at the
effective in reducing the operating temperature of the seal even in
rotary OD and the conductive thermal resistance of the rotary,
extreme operating conditions such as dry running and pump dead
which is significantly larger than the thermal resistances associated
head. A significant benefit of the integral heat sink design is that it
with the heat sink. Therefore, for cases such as shown in Figure
improves thermal performance of the seal without mixing the
10b at condition “G” the seal interface runs much cooler than the
coolant with the process fluid.
seal chamber.
The thermal resistance models indicate that cooling of the seal REFERENCES
interface for these experiments is limited by the convective thermal
resistance between the heat sink cover and coolant, and the con- Baker, M., 2002, “Thermomechanical Stresses and Deformation in
ductive thermal resistance of the heat sink cover. The convective Mechanical Seals with Micro Heat Sinks,” MSME Thesis,
thermal resistance is decreased by simply increasing the flowrate University of Kentucky.
through the heat sink and approximately is halved for a doubling Buck, G. S., 1989, “Heat Transfer in Mechanical Seals,”
of the flowrate. The convective thermal resistance may be further Proceedings of the Sixth International Pump Users Symposium,
reduced by optimizing the pin spacing in the heat sink. The heat Turbomachinery Laboratory, Texas A&M University, College
sink cover thermal resistance is decreased by reducing the Station, Texas, pp. 9-16.
thickness, Lc, of the cover. The present thickness is approximately
3.0 mm and is required because the O-ring seal is used both on the Despa, M., Kelly, K., and Collier, December 1999, “Injection
stationary OD and ID to isolate the heat sink coolant from the Molding of Polymeric LIGA HARM’s,” Journal of
pumped fluid. Microsystems Technology, 6, (2).
The experimental results also indicate that the pressure drop Harsh, M. S. and Ehrfeld, W., March 1998, “Mass Production of
across the heat sink is very small (<3 psi). This is at first surprising Microdevices with Extreme Aspect Ratios by Electroforming,”
given the very small scale of the heat sink coolant passages. Plating Surface Finishing.
However, Marques and Kelly (2004) show that this result is con-
sistent with scaling laws of pressure drop. The pressure drop across Johns, G. M. and Stephens, L. S., 2003, “Performance of a WC
the heat sink was constant for a given flowrate for the 56.4 hour Coated Mechanical Seal Prototype with Integral Micro Heat
cumulative run time. This indicates that no clogging of the heat Exchanger,” Proceedings of the IGTI, ASME Turbo Expo, Paper
sink channels occurred. This result, though, is largely dependent on No. GT2003-38856.
the quality of the coolant supply. Recall that in these tests a 3 Johns, G. S., 2003, “An Experimental Investigation of a Tungsten
micron filter element was used to filter tap water. During the Carbide Coated Prototype Mechanical Seal Ring with an
duration of all tests this filter was never changed. Finally, this result Integral Micro Heat Exchanger,” MSME.
is only indicative of the short-term operation of the heat sink.
Kelly, K. W., Harris, C., Stephens, L. S., Marques, C., and Foley,
Future work will examine the long-term “fouling” of the heat sink.
D. 2001, “Industrial Applications for LIGA-Fabricated Micro
Finally, the present materials of construction of the prototype
Heat Exchangers,” SPIE 2001 Symposium on Micromachining
stationary ring are not very attractive to pump users. As this paper
and Microfabrication, Proceedings 4559, San Francisco,
detailed, the present prototypes are fabricated with different layers
California.
of nickel and tungsten carbide on a stainless steel substrate, and
their purpose is to examine thermal performance and mechanical Lebeck, A. O., 1991, Principles and Design of Mechanical Face
design issues. There is ongoing work to fabricate the stationary Seals, ISBN 0471515337, Interscience, Book and Disk Edition.
seal ring directly from monolithic silicon carbide, tungsten carbide, Marques, C. and Kelly, K., 2004, “Fabrication and Performance of
and silicon nitride. Figure 12 shows the first heat sink seal ring a Pin Fin Micro Heat Exchanger,” To appear in ASME Journal
prototype fabricated of silicon nitride resulting from that work. of Heat Transfer.
These materials of construction are a large piece of the develop-
ment puzzle that will make the heat sink mechanical seal attractive Schneider, D. and Stephens, L. S., 2003, “Experimental Wear
to pump users. Results for a Water Cooled Mechanical Seal Prototype
Operating Under Dry Running Conditions,” Proceedings of the
40th Annual Meeting of the Society of Engineering Science.
Stephens, L. S. and Kelly, K. W., 1997, “Bearings and Mechanical
Seals Enhanced with Microstructures,” Patent Disclosure #9623,
Louisiana State University, (US Patent #6,149,160).
Stephens, L. S. and Kelly, K. W., 2001, “An End Face Mechanical
Seal with Integral Micro Heat Exchanger and Adaptor Plate,”
University of Kentucky Patent Disclosure #1059, (Patent
Pending).
Stephens, L. S., Kelly, K. W., Kountouris, D., McClean, J., and
Coynell, J., June 2001, “A Micro Heat Sink for Cooling Macro-
Scale Conformal Surfaces under the Influence of Thrust and
Frictional Forces,” IEEE/ASME Journal of Microelectro-
mechanical Systems, 10, (2), pp. 222-231.
Stephens, L. S., Simhadri, S., Kelly, K. W., and Meletis, E. I., 1998,
“Mechanical Property Evaluation of Electroplated, High Aspect
Figure 12. Heat Sink Seal Prototype Fabricated from Silicon Ratio Microstructures,” Proceedings of the Materials Research
Nitride. Society 1998 Spring Meeting, San Francisco, California.
126 PROCEEDINGS OF THE TWENTY-SECOND INTERNATIONAL PUMP USERS SYMPOSIUM • 2005
ACKNOWLEDGEMENTS
The authors wish to thank the Defense Advanced Research
Projects Agency for their support of this work under contract
number DABT63-99-1-0019, and the U.S. Department of
Education for their support of this work under the GAANN
Fellowship Program. The authors would also like to thank K.W.
Kelly of Louisiana State University for supplying the heat sink pro-
totypes.