Caroline XY is SENSIA's latest model of Quantitative


Optical Gas Imaging (QOGI) for the detection of
fugitive emissions of methane, SF6, methanol,
refrigerant gases, ammonia and others gases
leaks. It integrates a spectrally optimized Quantification Joystick & ATEX Lightweight
Analytics Touchscreen Certification Design
high-resolution uncooled detector that detects
the 90% of diffused gas emissions caused by
leaks.

Quantitative OGI
SENSIA Handheld cameras integrate a very reliable
software which implements strongly tested
algorithms for gas detection combined with the
most advanced signal integration technology and
data analytics. This embedded processing based
on SENSIA’s Redlook technology allows the QOGI
to perform sophisticated analytics as Quantification
of the flow rate of the observed gas.
With SENSIA QOGI cameras, you can scan broad
sections of equipment and survey areas where
traditional contact measurement tools cannot
access.

Leak Detection and Repair


SENSIA Handheld cameras are compatible with
SENSIA Gas Sniffer 4.0, which allows the user to
obtain the gas column density of the gas flume on
screen fulfilling the Smart LDAR and Method 21
protocols simultaneously. Metadata linked to the
survey for easy leaks tracking.

Powering Smart Industry


TM
Redlook Handheld shows a very visual and predictive interface that has been developed using big-size
buttons and smart element distribution to optimize and ease the user experience.

Temperature Auto-contrast Up to 5 color Saturated pixels


indicator mode palettes colored
Shows the precise Enhancement of the Different color palette Any pixel exposed to
temperature value of thermal image to get available by double extreme temperatures
those elements shown the optimum clicking on the palette is hightlighted and a
on the center of the temperature values for bar and providing the warning indicator is
image. each scenario. temperture in Celsius. triggered.

Specifications Gases detected

FPA Uncooled 640 x 480 px 1,3-Butadiene Phenol


Pixel Pitch 17 µm Acetic Acid Propylene
NETD <22mK @ +30ºC Acrolein R11
Spectral Region 7 to 14 Acrylic Acid R12
Lenses 20 mm | 35 mm Ammonia R123
Accuracy ± 1ºC (from 0ºC to 60ºC Scene Temp.) Ethanol R125
Data Protocol GigE 9 Hz / 25 Hz R13
Ethyl Hexyl Acrylate
Memory Storage SD card up to 256 GB
Ethylene R134A
Autonomy 3 x 3 hr
Ethylene Glycol R13B1
Display TFT LCD panel 5” HD
Ethylene Oxide R417A
Weight 2,1 kg
Isoprene R422A
Size 187 x 165 x 68 mm
Methane R508A
Operating Temp. Range -10ºC to +50ºC
Methanol Sulfur Dioxide
Storage Temp. Range -40ºC to +71ºC
EMC (EN 61326:2013)
Nitrogen trifluoride Sulfur Hexafluoride
IP65 (EN 60529:2018) Vinyl Chloride
Certifications Nitrous Oxide
ATEX Zone II (EN 60079:2013)
II 3G Ex ec IIC T4 Gc

Specifications are subject to change.


Features Under Demand
For the most up-to-date specifications, please
Gas Sniffer 4.0 contact to: contact@sensia-solutions.com

HEADQUARTERS QUALITY POLICIES


TM

Sensia Solutions S.L. Mon-Fri: 9:00 AM - 6:00 PM


Av. Gregorio Peces Barba, 1 +34 91 055 92 90 (GTM +1)
28919 Leganés, Madrid
contact@sensia-solutions.com
www.sensia-solutions.com SENSIA

You might also like