You are on page 1of 33

ø22 Switches & Pilot Lights

Emergency Stop Switches


YW Series Satisfy International Standards
• Safety Lock Mechanism
• Direct Opening Action
• Safe Pushbutton Design

Non-illuminated Illuminated

Easy Operation
• Push-to-lock, Pull/Turn-to-release
YW emergency stop switches can be unlatched by either pulling or
turning the operator.

Unlatching by Unlatching by
pulling turning

Innovative Design, Space-Saving, Safety, Unibody Pilot Lights


and Self-Cleaning Contacts
• Higher Brightness
• Measures only 42mm depth behind the panel
• Four Lens Shapes
• Panel Mounting

(Emergency Stop Switch)

• See website for details on approvals and standards.

Flush Flush Extended Dome


w/marking

Key Selector Switches


A variety of operations, key removal positions, and circuits.

Plastic Bezel Metal Bezel

B-269
Switches & Pilot Lights
Save

New Contact
Block Design YW series
Metal bezels are available for
pushbuttons, illuminated
APEM
pushbuttons, selector switches,
and key selector switches. Switches &
Pilot Lights

Control Boxes
FA CB CB FA CB Emergency
Stop Switches
Enabling
10 10 10 Switches
CB Safety Products
30
Explosion Proof
15 15
CB: Contact block Terminal Blocks
30 FA: Full-voltage adapter
Relays & Sockets

The contact block design reduces the depth behind the panel. Circuit
Protectors

Power Supplies

LED Illumination

Controllers

Operator
Reliable Interfaces

Sensors

AUTO-ID
Retained Locking Lever • Heavy-Duty Rugged Construction
• Self-Cleaning Wiping-Action Contacts with Scored Contact Surfaces
Lock Unlock

➁ ➀ Spring Flush Silhouette

Scored Surface ø16

ø22
Movable
Contact ø30

Stationary Miniature
Contact
Pilot Lights
(1) Normal State (2) Wiping (3) Fully Depressed

HW
Safety TW

YW
Integrated Finger-safe Terminal Cover
Degree of Protection: IP20 (From panel front: IP65)

B-270
Switches & Pilot Lights

YW Series Switches & Pilot Lights


Space-saving, 10-mm-thick contact blocks. Removable operator.

APEM

Switches &
Pilot Lights

Control Boxes

Emergency
Stop Switches
Enabling
Switches

Safety Products

Explosion Proof

Terminal Blocks

Relays & Sockets

Circuit
Protectors Contact Ratings (Contact Block)
Power Supplies Rated Insulation Voltage 600V
Rated Thermal Current 10A
LED Illumination
Operating Voltage 24V 120V 240V 380V
Controllers AC Resistive Load (AC-12) 10A 10A 6A 2A
Operator
50/60 Hz Inductive Load (AC-15) 10A 6A 3A 1.9A
Interfaces Resistive Load (DC-12) 8A 2.2A 1.1A —
DC
Sensors Inductive Load (DC-13) 4A 1.1A 0.55A —

AUTO-ID

LED Illuminated Unit Specifications


Pilot Light (removable lamp terminal type)
Flush Silhouette
Illuminated Pushbutton
Unit LED Lamp
ø16
Unit Type Input Type Rated Voltage Operating Voltage Color Code Lamp Base Part No. Rated Voltage Current Draw Color Code
ø22 8mA (A, R, Y)
6V AC/DC 6V AC/DC LSED-6N 6V AC/DC
6mA (G, PW, S)
ø30 7mA (A, R, Y) A: amber
12V AC/DC 12V AC/DC LSED-1N 12V AC/DC G: green
Pilot Light ±10% A: amber 6mA (G, PW, S)
Miniature Full Voltage PW: pure white
(removable G: green 4mA (A, R, Y)
24V AC/DC 24V AC/DC LSED-2N 24V AC/DC R: red
lamp terminal PW: pure white 4mA (G, PW, S)
Pilot Lights S: blue
type) 110V AC/DC 110V AC/DC R: red BA9S/13 LSED-HN 110V AC/DC 3mA Y: yellow
S: blue
230/240V AC/DC 207 to 250V AC/DC LSED-M3N 230/240V AC/DC 3mA
Illuminated W: white
100/110V AC 100/110V AC Specify a color
Pushbutton Transformer Y: yellow code in place of
(pilot light 200/220V AC 200/220V AC ±10% 8mA (A, R, Y)
HW LSED-6N 6V AC/DC  in the Part No.
only) 115/120V AC 115/120V AC 6mA (G, PW, S)
TW 50/60 Hz 230/240V AC 207 to 250V AC

YW

Pilot Light (unibody type)


Unit Type Rated Voltage Operating Voltage Current Draw Color Code
16mA (A, R, W, Y) A: amber
6V AC/DC 6V AC/DC
13mA (G, PW, S) G: green
12V AC/DC 12V AC/DC ±10% 20mA PW: pure white
Pilot Light
R: red
(unibody type) 24V AC/DC 24V AC/DC 20mA
S: blue
100/110V AC (50/60 Hz sine wave) 100/110V AC 20mA W: white
230/240V AC (50/60 Hz sine wave) 230/240V AC 207 to 250V AC 20mA Y: yellow

B-271
ø22 YW Series Switches & Pilot Lights

Switches & Pilot Lights


Incandescent Illuminated Unit Specifications
Pilot Light (removable lamp terminal type)
Illuminated Pushbutton
Unit Incandescent Lamp
Unit Type Input Type Rated Voltage Operating Voltage Color Code Lamp Base Part No. Rating
6V AC/DC 6V AC/DC LS-T6 1W (6.3V)
Pilot Light Full Voltage 12V AC/DC 12V AC/DC A: amber LS-T8 1W (18V)
(removable lamp 24V AC/DC 24V AC/DC G: green LS-T3 1W (30V) APEM
terminal type) ±10% R: red
100/110V AC 100/110V AC BA9S/13 Switches &
Transformer S: blue Pilot Lights
Illuminated 200/220V AC 200/220V AC W: white
(pilot light only) LS-T6 1W (6.3V)
Pushbutton 50/60 Hz 115/120V AC 115/120V AC Y: yellow Control Boxes

230/240V AC 207 to 250V AC Emergency


Stop Switches
Enabling
Switches

Specifications Mounting Hole Layout Safety Products

Operating temperature: –20 to +55°C (no freezing) R0.8 max. Explosion Proof
The 3.2-mm-wide key recess
Operating Operating humidity: 45 to 85% RH (no condensation) 3.2 +0.2
0 is necessary when the anti-rotation
Conditions Storage temperature: –45 to +80°C ø22
.3 +0
.4
ring is used. Terminal Blocks
Storage humidity: 95% RH maximum 0

24.1 +0.4
0
Degree of From panel front: IP65 (IEC 60529) Relays & Sockets
Protection Terminal: IP20 (IEC 60529) Circuit
Protectors
Insulation
100 MΩ B
Resistance A Power Supplies
Dielectric Contact block: 2,500V, 1 minute
LED Illumination
Strength Pilot light: 2,000V, 1 minute
<Emergency stop switch> Controllers
Operating extremes / Damage limits:
Operator
10 to 500 Hz, amplitude 0.35 mm. acceleration 50 m/s2 (5G) Interfaces
Vibration
<Pushbutton, pilot light, illluminated pushbutton, selector Unit A (mm) B (mm)
Resistance Sensors
switch, and key selector switch>
Operating extremes: 5 to 55 Hz, amplitude 0.5 mm Emergency stop switch 50 min. 50 min.
Damage limits: 30 Hz, amplitude 1.5 mm Pushbutton AUTO-ID
Selector switch 50 min. 30 min.
<Emergency stop switch>
Key selector switch
Operating extremes: 150 m/s2 (10G)
Damage limits: 1,000 m/s2 (100G) Mushroom pushbutton 50 min. 40 min.
Shock
<Pushbutton, pilot light, illluminated pushbutton, selector Pilot light (with removable lamp terminal) 30 min.∗ 30 min. Flush Silhouette
Resistance
switch, and key selector switch> Pilot light (unibody) 50 min. 30 min.
Operating extremes: 100 m/s2 (10G) ø16
Damage limits: 1,000 m/s2 (100G) ∗ Keep a minimum spacing of 50 mm when using a lamp of over 1W.
<Emergency stop switch> ø22
250,000 (single contact block)
ø30
<Pushbutton and illuminated pushbutton>
Momentary: 5,000,000 (single contact block)
Mechanical Miniature
1,000,000 (double contact block)
Life (minimum
Maintained: 250,000 (single contact block)
operations) Pilot Lights
100,000 (double contact block)
<Selector switch and key selector switch>
250,000 (single contact block)
100,000 (double contact block)
<Emergency stop switch> HW
Electrical Life 100,000 (single contact block)
(minimum <Pushbutton, selector switch, and key selector switch> TW
operations) 100,000 (single contact block)
50,000 (double contact block) YW

B-272
Switches & Pilot Lights
ø22 YW Series Emergency Stop Switches

Non-illuminated Emergency Stop Switches (Pushlock Pull/Turn Reset)


Package Quantity: 1
Contact Block Mounting Position
Style Contact Part No. Button Color Code
1 2 3
ø40mm Mushroom 1NC — — NC YW1B-V4E01R
2NC NC — NC YW1B-V4E02R
APEM 3NC NC NC NC YW1B-V4E03R
Red only
Switches & 1NO-1NC NO — NC YW1B-V4E11R
Pilot Lights
1NO-2NC NO NC NC YW1B-V4E12R
Control Boxes
2NO-1NC NO NC NO YW1B-V4E21R
Emergency
Stop Switches • When pressed, the button is locked in the depressed position, and is reset when either pulled or turned clockwise.
Enabling
Switches
Dimensions
Safety Products Panel Thickness 0.8 to 6 Contact Block Mounting Position
Explosion Proof 1 2 3
10 10 10

Terminal Blocks

Relays & Sockets


M3.5 Terminal Screw
Contact Block Locking Ring Gasket
Circuit
Protectors
28.6

Power Supplies
41.4
LED Illumination
0
Controllers ø4
45.8 32.5 30
Operator
Interfaces

Sensors

AUTO-ID
Illuminated Emergency Stop Switches (Pushlock Pull/Turn Reset)
Package Quantity: 1
Contact Block Mounting Position Lens Color
Flush Silhouette Style Lamp Contacts Part No. ➂ Operating Voltage Code
1 2 3 Code
ø16 ø40mm Mushroom 1NC — FA NC YW1L-V4E01Q0R
0: without lamp
ø22 Without Lamp 2NC NC FA NC YW1L-V4E02Q0R
250V AC/DC max.
ø30 1NO-1NC NO FA NC YW1L-V4E11Q0R
1NC — FA NC YW1L-V4E01Q➂R 2: 6V AC/DC
Miniature
3: 12V AC/DC
LED 2NC NC FA NC YW1L-V4E02Q➂R 4: 24V AC/DC Red only
Pilot Lights
H: 110V AC/DC
1NO-1NC NO FA NC YW1L-V4E11Q➂R M3: 230/240V AC/DC
1NC — FA NC YW1L-V4E01Q➂R
5: 6V AC/DC
HW Incandescent 2NC NC FA NC YW1L-V4E02Q➂R 6: 12V AC/DC
7: 24V AC/DC
1NO-1NC NO FA NC YW1L-V4E11Q➂R
TW
• Specify an operating voltage code in place of ➂ in the Part No. FA: Full voltage adapter
YW
• When pressed, the button is locked in the depressed position, and is reset when either pulled or turned clockwise.

Dimensions
M3.5 Terminal Screw Panel Thickness 0.8 to 6 Contact Block Mounting Position
Full-Voltage Adapter
3
1 2
10 10 10

M3.5 Terminal Screw Locking Ring Gasket


Contact Block
28.6

41.4

0
ø4
45.8 32.5 30

B-273
ø22 YW Series Switches & Pilot Lights

Switches & Pilot Lights


Pushbuttons with Plastic Bezel (Pushlock Pull/Turn Reset)
Package Quantity: 1
Contact Block Mounting Position ➀ Button Color
Shape Operation Contact Part No.
1 2 3 Code
Flush 1NO NO — — YW1B-M1E10➀
1NC — — NC YW1B-M1E01➀
2NO NO — NO YW1B-M1E20➀
2NC NC — NC YW1B-M1E02➀ APEM

Momentary 1NO-1NC NO — NC YW1B-M1E11➀ Switches &


B: black Pilot Lights
3NO NO NO NO YW1B-M1E30➀ G: green
3NC NC NC NC YW1B-M1E03➀ Control Boxes
R: red
2NO-1NC NO NC NO YW1B-M1E21➀ S: blue Emergency
1NO-2NC NO NC NC YW1B-M1E12➀ W: white Stop Switches
Y: yellow Enabling
1NO NO — — YW1B-A1E10➀ Switches
1NC — — NC YW1B-A1E01➀ Safety Products
Maintained 2NO NO — NO YW1B-A1E20➀
2NC NC — NC YW1B-A1E02➀ Explosion Proof

1NO-1NC NO — NC YW1B-A1E11➀ Terminal Blocks


Extended 1NO NO — — YW1B-M2E10➀
1NC — — NC YW1B-M2E01➀ Relays & Sockets

Momentary 2NO NO — NO YW1B-M2E20➀ Circuit


B: black Protectors
2NC NC — NC YW1B-M2E02➀ G: green
1NO-1NC NO — NC YW1B-M2E11➀ Power Supplies
R: red
1NO NO — — YW1B-A2E10➀ S: blue LED Illumination
1NC — — NC YW1B-A2E01➀ W: white
Y: yellow Controllers
Maintained 2NO NO — NO YW1B-A2E20➀
2NC NC — NC YW1B-A2E02➀ Operator
Interfaces
1NO-1NC NO — NC YW1B-A2E11➀
1NO NO — — YW1B-M4E10➀ Sensors
Mushroom ø40mm
1NC — — NC YW1B-M4E01➀ AUTO-ID
Momentary 2NO NO — NO YW1B-M4E20➀
B: black
2NC NC — NC YW1B-M4E02➀ G: green
1NO-1NC NO — NC YW1B-M4E11➀ R: red
1NO NO — — YW1B-A4E10➀ S: blue Flush Silhouette
1NC — — NC YW1B-A4E01➀ W: white
Y: yellow ø16
Maintained 2NO NO — NO YW1B-A4E20➀
2NC NC — NC YW1B-A4E02➀ ø22
1NO-1NC NO — NC YW1B-A4E11➀
ø30
Note: Specify a button color code in place of ➀ in the Part No.
Miniature
Dimensions
Pilot Lights
Panel Thickness: 0.8 to 6 Contact Block Mounting Position
Gasket
3
1 2
10

HW
10

0.5
M3.5 Terminal Screw
Contact Block
TW

Lock YW
Flush Locking Ring
28.6
(Button Diameter)
ø23.6

41.4

ø29

45.8 11 30

Extended Mushroom
28.6
28.6

(Button Diameter)
(Button Diameter)
ø23.6

41.4
41.4

ø40

ø29
11
30 11
45.8 19 45.8 20.5 30
All dimensions in mm.

B-274
Switches & Pilot Lights
ø22 YW Series Switches & Pilot Lights

Pushbuttons with Metal Bezel


Package Quantity: 1
Contact Block Mounting Position ➀ Button Color
Shape Operation Contact Part No.
1 2 3 Code
Flush 1NO NO — — YW4B-M1E10➀
1NC — — NC YW4B-M1E01➀
2NO NO — NO YW4B-M1E20➀
APEM 2NC NC — NC YW4B-M1E02➀
Switches & Momentary 1NO-1NC NO — NC YW4B-M1E11➀
Pilot Lights B: black
3NO NO NO NO YW4B-M1E30➀ G: green
Control Boxes 3NC NC NC NC YW4B-M1E03➀ R: red
Emergency 2NO-1NC NO NC NO YW4B-M1E21➀ S: blue
Stop Switches
1NO-2NC NO NC NC YW4B-M1E12➀ W: white
Enabling Y: yellow
Switches 1NO NO — — YW4B-A1E10➀
Safety Products 1NC — — NC YW4B-A1E01➀
Maintained 2NO NO — NO YW4B-A1E20➀
Explosion Proof 2NC NC — NC YW4B-A1E02➀
Terminal Blocks 1NO-1NC NO — NC YW4B-A1E11➀
Extended 1NO NO — — YW4B-M2E10➀
Relays & Sockets 1NC — — NC YW4B-M2E01➀
Circuit Momentary 2NO NO — NO YW4B-M2E20➀
Protectors B: black
2NC NC — NC YW4B-M2E02➀ G: green
Power Supplies 1NO-1NC NO — NC YW4B-M2E11➀ R: red
1NO NO — — YW4B-A2E10➀ S: blue
LED Illumination
1NC — — NC YW4B-A2E01➀ W: white
Controllers
Y: yellow
Maintained 2NO NO — NO YW4B-A2E20➀
Operator 2NC NC — NC YW4B-A2E02➀
Interfaces
1NO-1NC NO — NC YW4B-A2E11➀
Sensors 1NO NO — — YW4B-M4E10➀
Mushroom ø40mm
AUTO-ID 1NC — — NC YW4B-M4E01➀
Momentary 2NO NO — NO YW4B-M4E20➀
B: black
2NC NC — NC YW4B-M4E02➀ G: green
1NO-1NC NO — NC YW4B-M4E11➀ R: red
1NO NO — — YW4B-A4E10➀ S: blue
Flush Silhouette
1NC — — NC YW4B-A4E01➀ W: white
ø16
Y: yellow
Maintained 2NO NO — NO YW4B-A4E20➀
ø22 2NC NC — NC YW4B-A4E02➀
1NO-1NC NO — NC YW4B-A4E11➀
ø30
Note: Specify a button color code in place of ➀ in the Part No.
Miniature
Dimensions
Pilot Lights
Panel Thickness: 0.8 to 6 Contact Block Mounting Position
Gasket
3
1 2
10

HW
10

M3.5 Terminal Screw 0.3


29.8

TW
Contact Block
Lock
YW Flush Locking Ring
28.6
(Button Diameter)

41.4
ø23.6

.5
ø29

45.8 11.3 30

Lock Lock
Extended Locking Ring Mushroom Locking Ring
28.6

28.6
(Button Diameter)

(Button Diameter)
41.4

41.4
ø23.6

ø40

.5
ø29
11.3 11.3
30 30
45.8 19 45.8 20.5
All dimensions in mm.

B-275
ø22 YW Series Switches & Pilot Lights

Switches & Pilot Lights


Pilot Lights (Unibody)
Package Quantity: 1
Shape Lamp Operating Voltage Part No. ➁ Lens Color Code
Flush 6V AC/DC YW1P-1UQ2➁
Full Voltage
12V AC/DC YW1P-1UQ3➁
LED 24V AC/DC YW1P-1UQ4➁ APEM
100/110V AC YW1P-1UQH➁ Switches &
Pilot Lights
230/240V AC YW1P-1UQM3➁
Control Boxes
Flush Marking 6V AC/DC YW1P-1BUQ2➁
Emergency
Full Voltage Stop Switches
12V AC/DC YW1P-1BUQ3➁
Enabling
LED 24V AC/DC YW1P-1BUQ4➁ Switches

A: amber Safety Products


100/110V AC YW1P-1BUQH➁
G: green
230/240V AC YW1P-1BUQM3➁ PW: pure white Explosion Proof
R: red
Extended 6V AC/DC YW1P-2TUQ2➁ S: blue Terminal Blocks
Full Voltage W: white
12V AC/DC YW1P-2TUQ3➁ Y: yellow Relays & Sockets

LED 24V AC/DC YW1P-2TUQ4➁ Circuit


Protectors
100/110V AC YW1P-2TUQH➁ Power Supplies
230/240V AC YW1P-2TUQM3➁ LED Illumination
Dome 6V AC/DC YW1P-2UQ2➁
Full Voltage Controllers
12V AC/DC YW1P-2UQ3➁ Operator
Interfaces
LED 24V AC/DC YW1P-2UQ4➁
Sensors
100/110V AC YW1P-2UQH➁
AUTO-ID
230/240V AC YW1P-2UQM3➁

Dimensions
Flush Silhouette
Flush Flush Marking
Locking Ring Locking Ring ø16

ø22

ø30

M3.5 M3.5 Miniature


Terminal Screw Terminal Screw
Gasket Gasket Pilot Lights
Panel Thickness 0.8 to 6 Panel Thickness 0.8 to 6
8
9. 9.
8
ø2 ø2

HW

TW
42.0 9.5 42.0 10
YW

Extended Locking Ring Dome Locking Ring

M3.5 M3.5
Terminal Screw Terminal Screw
Gasket Gasket
Panel Thickness 0.8 to 6 Panel Thickness 0.8 to 6
.8 8
ø2
9 9.
ø2

42.0 15.5 42.0 15.5


All dimensions in mm.

B-276
Switches & Pilot Lights
ø22 YW Series Switches & Pilot Lights

Pilot Lights (with Removable Lamp Terminal)


Package Quantity: 1
Shape Lamp Operating Voltage Part No. ➁ Lens Color Code
Flush A (amber), C (clear),
Full Voltage Without Lamp 250V AC/DC max. YW1P-1EQ0➁ G (green), R (red), S (blue),
W (white), Y (yellow)
6V AC/DC YW1P-1EQ2➁
APEM

Switches & 12V AC/DC YW1P-1EQ3➁ A (amber), G (green),


Pilot Lights
PW (pure white), R (red),
LED 24V AC/DC YW1P-1EQ4➁ S (blue), W (white), Y (yellow)
Control Boxes
110V AC/DC Built-in LED lamp: LSED-➂➁N
Emergency YW1P-1EQH➁
Stop Switches
Enabling 230/240V AC/DC YW1P-1EQM3➁
Switches
6V AC/DC YW1P-1EQ5➁ A (amber), C (clear),
Safety Products
G (green), R (red), S (blue),
Incandescent 12V AC/DC YW1P-1EQ6➁
Explosion Proof W (white), Y (yellow)
24V AC/DC Built-in incandescent lamp: LS-T➂
Terminal Blocks YW1P-1EQ7➁
Flush 100/110V AC YW1P-1EH2➁
Relays & Sockets
Transformer A (amber), G (green),
Circuit 200/220V AC YW1P-1EM2➁ PW (pure white), R (red),
Protectors LED S (blue), W (white), Y (yellow)
115/120V AC YW1P-1EH22➁
Power Supplies Built-in LED lamp: LSED-6➁N
230/240V AC YW1P-1EM42➁
LED Illumination
100/110V AC YW1P-1EH5➁
Controllers
A (amber), C (clear),
Operator 200/220V AC YW1P-1EM5➁ G (green), R (red), S (blue),
Interfaces Incandescent
W (white), Y (yellow)
115/120V AC YW1P-1EH25➁
Sensors Built-in incandescent lamp: LS-T6
230/240V AC YW1P-1EM45➁
AUTO-ID
Flush Marking A (amber), G (green), R (red),
Without Lamp 250V AC/DC max. YW1P-1BEQ0➁
Full Voltage S (blue), W (white), Y (yellow)
6V AC/DC YW1P-1BEQ2➁
Flush Silhouette
12V AC/DC YW1P-1BEQ3➁ A (amber), G (green),
ø16 PW (pure white), R (red),
LED 24V AC/DC YW1P-1BEQ4➁ S (blue), W (white), Y (yellow)
ø22
110V AC/DC Built-in LED lamp: LSED-➂➁N
YW1P-1BEQH➁
ø30
230/240V AC/DC YW1P-1BEQM3➁
Miniature
6V AC/DC YW1P-1BEQ5➁
Pilot Lights A (amber), G (green), R (red),
Incandescent 12V AC/DC YW1P-1BEQ6➁ S (blue), W (white), Y (yellow)
Built-in incandescent lamp: LS-T➂
24V AC/DC YW1P-1BEQ7➁
Flush Marking 100/110V AC YW1P-1BEH2➁
HW
Transformer A (amber), G (green),
200/220V AC YW1P-1BEM2➁ PW (pure white), R (red),
TW
LED S (blue), W (white), Y (yellow)
115/120V AC YW1P-1BEH22➁
YW Built-in LED lamp: LSED-6➁N
230/240V AC YW1P-1BEM42➁

100/110V AC YW1P-1BEH5➁

200/220V AC YW1P-1BEM5➁ A (amber), G (green), R (red),


Incandescent S (blue), W (white), Y (yellow)
115/120V AC YW1P-1BEH25➁ Built-in incandescent lamp: LS-T6

230/240V AC YW1P-1BEM45➁

Note: S pecify a lens color code in place of ➁ in the Part No.


Clear lenses are used for PW (pure white) illumination of pilot lights.

B-277
ø22 YW Series Switches & Pilot Lights

Switches & Pilot Lights


Pilot Lights (with Removable Lamp Terminal)
Package Quantity: 1
Shape Lamp Operating Voltage Part No. ➁ Lens Color Code
Extended A (amber), C (clear),
Full Voltage Without Lamp 250V AC/DC max. YW1P-2TEQ0➁ G (green), R (red), S (blue),
W (white), Y (yellow)
6V AC/DC YW1P-2TEQ2➁ APEM
12V AC/DC YW1P-2TEQ3➁ A (amber), G (green), Switches &
Pilot Lights
PW (pure white), R (red),
LED 24V AC/DC YW1P-2TEQ4➁ S (blue), W (white), Y (yellow) Control Boxes
110V AC/DC Built-in LED lamp: LSED-➂➁N
YW1P-2TEQH➁ Emergency
Stop Switches
230/240V AC/DC YW1P-2TEQM3➁ Enabling
Switches
6V AC/DC YW1P-2TEQ5➁ A (amber), C (clear), Safety Products
G (green), R (red), S (blue),
Incandescent 12V AC/DC YW1P-2TEQ6➁ W (white), Y (yellow) Explosion Proof
24V AC/DC Built-in incandescent lamp: LS-T➂
YW1P-2TEQ7➁ Terminal Blocks
Extended 100/110V AC YW1P-2TEH2➁ Relays & Sockets
Transformer A (amber), G (green),
200/220V AC YW1P-2TEM2➁ PW (pure white), R (red), Circuit
LED Protectors
S (blue), W (white), Y (yellow)
115/120V AC YW1P-2TEH22➁
Built-in LED lamp: LSED-6➁N Power Supplies
230/240V AC YW1P-2TEM42➁ LED Illumination
100/110V AC YW1P-2TEH5➁ Controllers
A (amber), C (clear),
200/220V AC YW1P-2TEM5➁ Operator
G (green), R (red), S (blue),
Incandescent Interfaces
W (white), Y (yellow)
115/120V AC YW1P-2TEH25➁ Built-in incandescent lamp: LS-T6 Sensors
230/240V AC YW1P-2TEM45➁ AUTO-ID
Dome A (amber), C (clear),
Full Voltage Without Lamp 250V AC/DC max. YW1P-2EQ0➁ G (green), R (red), S (blue),
W (white), Y (yellow)
6V AC/DC YW1P-2EQ2➁ Flush Silhouette

12V AC/DC YW1P-2EQ3➁ A (amber), G (green), ø16


PW (pure white), R (red),
LED 24V AC/DC YW1P-2EQ4➁ S (blue), W (white), Y (yellow) ø22

110V AC/DC Built-in LED lamp: LSED-➂➁N


YW1P-2EQH➁ ø30

230/240V AC/DC YW1P-2EQM3➁ Miniature

6V AC/DC YW1P-2EQ5➁ A (amber), C (clear), Pilot Lights


G (green), R (red), S (blue),
Incandescent 12V AC/DC YW1P-2EQ6➁ W (white), Y (yellow)
24V AC/DC Built-in incandescent lamp: LS-T➂
YW1P-2EQ7➁
HW
Dome 100/110V AC YW1P-2EH2➁
Transformer A (amber), G (green), TW
200/220V AC YW1P-2EM2➁ PW (pure white), R (red),
LED S (blue), W (white), Y (yellow) YW
115/120V AC YW1P-2EH22➁
Built-in LED lamp: LSED-6➁N
230/240V AC YW1P-2EM42➁

100/110V AC YW1P-2EH5➁
A (amber), C (clear),
200/220V AC YW1P-2EM5➁ G (green), R (red), S (blue),
Incandescent
W (white), Y (yellow)
115/120V AC YW1P-2EH25➁ Built-in incandescent lamp: LS-T6
230/240V AC YW1P-2EM45➁

Note: Specify a lens color code in place of ➁ in the Part No.


Clear lenses are used for PW (pure white) illumination of pilot lights.

B-278
Switches & Pilot Lights
ø22 YW Series Switches & Pilot Lights

Dimensions  All dimensions in mm

Pilot Lights (with Removable Lamp Terminal)


Flush Flush Marking
Full Voltage Panel Thickness 0.8 to 6 Full Voltage Panel Thickness 0.8 to 6

APEM

Switches &
Pilot Lights

Control Boxes
M3.5 Terminal Screw Gasket Gasket
M3.5 Terminal Screw
Emergency Locking Ring Locking Ring

9.8

9.8
Stop Switches

ø2

ø2
Enabling
Switches

24

24
Safety Products
46.2 9.5 29.6 46.2 10 29.6
Explosion Proof

Terminal Blocks
Transformer Transformer
Relays & Sockets Panel Thickness 0.8 to 6 Panel Thickness 0.8 to 6
Circuit
Protectors

Power Supplies

LED Illumination

Controllers
Gasket Gasket
M3.5 Terminal Screw M3.5 Terminal Screw
Operator Locking Ring Locking Ring
9.8

9.8
Interfaces
ø2

ø2
Sensors
24

24
AUTO-ID

63.3 9.5 29.6 63.3 10 29.6

Flush Silhouette

ø16 Extended Dome


Full Voltage Panel Thickness 0.8 to 6 Full Voltage Panel Thickness 0.8 to 6
ø22

ø30

Miniature

Pilot Lights
Gasket Gasket
M3.5 Terminal Screw M3.5 Terminal Screw
Locking Ring Locking Ring
9.8

9.8
ø2

ø2

HW
24

24

TW
46.2 15.5 29.6 46.2 15.5 29.6
YW

Transformer Transformer
Panel Thickness 0.8 to 6 Panel Thickness 0.8 to 6

Gasket Gasket
M3.5 Terminal Screw M3.5 Terminal Screw
Locking Ring Locking Ring
9.8
9.8

ø2
ø2

24
24

63.3 15.5 29.6 63.3 15.5 29.6

B-279
ø22 YW Series Switches & Pilot Lights

Switches & Pilot Lights


Illuminated Pushbuttons with Plastic Bezel
Package Quantity: 1
Contact Block
Mounting Position ➂ Operating
Shape Lamp Operation Contact Part No. ➁ Lens Color Code
Voltage Code
1 2 3
Extended 1NO NO FA — YW1L-M2E10Q0➁
1NC — FA NC YW1L-M2E01Q0➁
Momentary 2NO NO FA NO YW1L-M2E20Q0➁ APEM
A: amber
2NC NC FA NC YW1L-M2E02Q0➁ G: green Switches &
1NO-1NC NO FA NC YW1L-M2E11Q0➁ 0: without lamp R: red Pilot Lights
Without Lamp
1NO NO FA — YW1L-A2E10Q0➁ 250V AC/DC max. S: blue Control Boxes
1NC — FA NC YW1L-A2E01Q0➁ W: white
Y: yellow Emergency
Maintained 2NO NO FA NO YW1L-A2E20Q0➁ Stop Switches
2NC NC FA NC YW1L-A2E02Q0➁ Enabling
Switches
1NO-1NC NO FA NC YW1L-A2E11Q0➁
1NO NO FA — YW1L-M2E10Q➂➁ Safety Products
1NC — FA NC YW1L-M2E01Q➂➁ A: amber Explosion Proof
Momentary 2NO NO FA NO YW1L-M2E20Q➂➁ G: green
2: 6V AC/DC PW: pure white
2NC NC FA NC YW1L-M2E02Q➂➁ 3: 12V AC/DC Terminal Blocks
R: red
1NO-1NC NO FA NC YW1L-M2E11Q➂➁ 4: 24V AC/DC
LED S: blue Relays & Sockets
1NO NO FA — YW1L-A2E10Q➂➁ H: 110V AC/DC W: white
1NC — FA NC YW1L-A2E01Q➂➁ M3: 230/240V Y: yellow Circuit
AC/DC Built-in LED lamp:
Protectors
Maintained 2NO NO FA NO YW1L-A2E20Q➂➁
LSED-➂➁N Power Supplies
2NC NC FA NC YW1L-A2E02Q➂➁
1NO-1NC NO FA NC YW1L-A2E11Q➂➁ LED Illumination
1NO NO FA — YW1L-M2E10Q➂➁
1NC — FA NC YW1L-M2E01Q➂➁ Controllers
A: amber
Momentary 2NO NO FA NO YW1L-M2E20Q➂➁ G: green Operator
2NC NC FA NC YW1L-M2E02Q➂➁ R: red Interfaces

1NO-1NC NO FA NC YW1L-M2E11Q➂➁ 5: 6V AC/DC S: blue Sensors


Incandescent 6: 12V AC/DC W: white
1NO NO FA — YW1L-A2E10Q➂➁ 7: 24V AC/DC Y: yellow AUTO-ID
1NC — FA NC YW1L-A2E01Q➂➁ Built-in
Maintained 2NO NO FA NO YW1L-A2E20Q➂➁ incandescent lamp:
2NC NC FA NC YW1L-A2E02Q➂➁ LS-T➂
1NO-1NC NO FA NC YW1L-A2E11Q➂➁
Flush Silhouette
Extended with 1NO NO FA — YW1L-MF2E10Q0➁
Full Shroud 1NC — FA NC YW1L-MF2E01Q0➁ ø16
Momentary 2NO NO FA NO YW1L-MF2E20Q0➁
A: amber ø22
2NC NC FA NC YW1L-MF2E02Q0➁ G: green
1NO-1NC NO FA NC YW1L-MF2E11Q0➁ 0: without lamp R: red ø30
Without Lamp
1NO NO FA — YW1L-AF2E10Q0➁ 250V AC/DC max. S: blue
1NC — FA NC YW1L-AF2E01Q0➁ W: white Miniature
Y: yellow
Maintained 2NO NO FA NO YW1L-AF2E20Q0➁
Pilot Lights
2NC NC FA NC YW1L-AF2E02Q0➁
1NO-1NC NO FA NC YW1L-AF2E11Q0➁
1NO NO FA — YW1L-MF2E10Q➂➁
1NC — FA NC YW1L-MF2E01Q➂➁ A: amber
G: green HW
Momentary 2NO NO FA NO YW1L-MF2E20Q➂➁
2: 6V AC/DC PW: pure white
2NC NC FA NC YW1L-MF2E02Q➂➁ 3: 12V AC/DC TW
R: red
1NO-1NC NO FA NC YW1L-MF2E11Q➂➁ 4: 24V AC/DC
LED S: blue
1NO NO FA — YW1L-AF2E10Q➂➁ H: 110V AC/DC YW
W: white
1NC — FA NC YW1L-AF2E01Q➂➁ M3: 230/240V Y: yellow
AC/DC Built-in LED lamp:
Maintained 2NO NO FA NO YW1L-AF2E20Q➂➁
2NC NC FA NC YW1L-AF2E02Q➂➁ LSED-➂➁N
1NO-1NC NO FA NC YW1L-AF2E11Q➂➁
1NO NO FA — YW1L-MF2E10Q➂➁
1NC — FA NC YW1L-MF2E01Q➂➁ A: amber
Momentary 2NO NO FA NO YW1L-MF2E20Q➂➁ G: green
2NC NC FA NC YW1L-MF2E02Q➂➁ R: red
1NO-1NC NO FA NC YW1L-MF2E11Q➂➁ 5: 6V AC/DC S: blue
Incandescent 6: 12V AC/DC W: white
1NO NO FA — YW1L-AF2E10Q➂➁ 7: 24V AC/DC Y: yellow
1NC — FA NC YW1L-AF2E01Q➂➁ Built-in
Maintained 2NO NO FA NO YW1L-AF2E20Q➂➁ incandescent lamp:
2NC NC FA NC YW1L-AF2E02Q➂➁ LS-T➂
1NO-1NC NO FA NC YW1L-AF2E11Q➂➁
Note: Specify a lens color code in place of ➁ in the Part No. FA: Full voltage adapter
Specify an operating voltage code in place of ➂ in the Part No.

B-280
Switches & Pilot Lights
ø22 YW Series Switches & Pilot Lights

Illuminated Pushbuttons with Plastic Bezel


Package Quantity: 1
Contact Block
Mounting Position ➂ Operating
Shape Lamp Operation Contact Part No. ➁ Lens Color Code
Voltage Code
1 2 3
Mushroom ø40mm 1NO NO FA — YW1L-M4E10Q0➁
1NC — FA NC YW1L-M4E01Q0➁
APEM Momentary 2NO NO FA NO YW1L-M4E20Q0➁
A: amber
Switches & 2NC NC FA NC YW1L-M4E02Q0➁ G: green
Pilot Lights
1NO-1NC NO FA NC YW1L-M4E11Q0➁ 0: without lamp R: red
Without Lamp
Control Boxes 1NO NO FA — YW1L-A4E10Q0➁ 250V AC/DC max. S: blue
Emergency 1NC — FA NC YW1L-A4E01Q0➁ W: white
Stop Switches Y: yellow
Maintained 2NO NO FA NO YW1L-A4E20Q0➁
Enabling
Switches 2NC NC FA NC YW1L-A4E02Q0➁
1NO-1NC NO FA NC YW1L-A4E11Q0➁
Safety Products
1NO NO FA — YW1L-M4E10Q➂➁
Explosion Proof 1NC — FA NC YW1L-M4E01Q➂➁ A: amber
Momentary 2NO NO FA NO YW1L-M4E20Q➂➁ G: green
Terminal Blocks 2: 6V AC/DC
2NC NC FA NC YW1L-M4E02Q➂➁ PW: pure white
3: 12V AC/DC R: red
Relays & Sockets 1NO-1NC NO FA NC YW1L-M4E11Q➂➁ 4: 24V AC/DC
LED S: blue
Circuit 1NO NO FA — YW1L-A4E10Q➂➁ H: 110V AC/DC W: white
Protectors
1NC — FA NC YW1L-A4E01Q➂➁ M3: 230/240V Y: yellow
AC/DC
Power Supplies Maintained 2NO NO FA NO YW1L-A4E20Q➂➁ Built-in LED lamp:
2NC NC FA NC YW1L-A4E02Q➂➁ LSED-➂➁N
LED Illumination
1NO-1NC NO FA NC YW1L-A4E11Q➂➁
Controllers 1NO NO FA — YW1L-M4E10Q➂➁
Operator 1NC — FA NC YW1L-M4E01Q➂➁ A: amber
Interfaces Momentary 2NO NO FA NO YW1L-M4E20Q➂➁ G: green
Sensors 2NC NC FA NC YW1L-M4E02Q➂➁ R: red
1NO-1NC NO FA NC 5: 6V AC/DC S: blue
YW1L-M4E11Q➂➁
AUTO-ID Incandescent 6:12V AC/DC W: white
1NO NO FA — YW1L-A4E10Q➂➁ 7:24V AC/DC Y: yellow
1NC — FA NC YW1L-A4E01Q➂➁ Built-in
Maintained 2NO NO FA NO YW1L-A4E20Q➂➁ incandescent lamp:
2NC NC FA NC YW1L-A4E02Q➂➁ LS-T➂
Flush Silhouette
1NO-1NC NO FA NC YW1L-A4E11Q➂➁
ø16
Note: Specify a lens color code in place of ➁ in the Part No. FA: Full voltage adapter
ø22 Specify an operating voltage code in place of ➂ in the Part No.

ø30
Dimensions
Miniature
(Illuminated Pushbuttons with Plastic Bezel)
Pilot Lights Panel Thickness: 0.8 to 6 Contact Block Mounting Position
M3.5 Terminal Screw
Full-voltage Adapter 3
Gasket 1 2
10 10 10

HW

TW
0.5
M3.5 Terminal Screw
YW Contact Block

Extended
28.6
(Lens Diameter)
ø23.6

41.4

ø29
11
30
45.8 19

Mushroom Extended with Full Shroud


28.6

28.6
(Lens Diameter)

41.4

41.4
ø40

.2
ø28
11
45.8 19 30
45.8 20.5 30
All dimensions in mm.

B-281
ø22 YW Series Switches & Pilot Lights

Switches & Pilot Lights


Illuminated Pushbuttons with Metal Bezel
Package Quantity: 1
Contact Block
Mounting Position ➂ Operating
Shape Lamp Operation Contact Part No. ➁ Lens Color Code
Voltage Code
1 2 3
Extended 1NO NO FA — YW4L-M2E10Q0➁
1NC — FA NC YW4L-M2E01Q0➁
Momentary 2NO NO FA NO YW4L-M2E20Q0➁ APEM
A: amber
2NC NC FA NC YW4L-M2E02Q0➁ G: green Switches &
1NO-1NC NO FA NC YW4L-M2E11Q0➁ 0: without lamp R: red Pilot Lights
Without Lamp
1NO NO FA — YW4L-A2E10Q0➁ 250V AC/DC max. S: blue Control Boxes
1NC — FA NC YW4L-A2E01Q0➁ W: white
Y: yellow Emergency
Maintained 2NO NO FA NO YW4L-A2E20Q0➁ Stop Switches
2NC NC FA NC YW4L-A2E02Q0➁ Enabling
Switches
1NO-1NC NO FA NC YW4L-A2E11Q0➁
1NO NO FA — YW4L-M2E10Q➂➁ Safety Products
1NC — FA NC YW4L-M2E01Q➂➁ A: amber Explosion Proof
Momentary 2NO NO FA NO YW4L-M2E20Q➂➁ G: green
2NC NC FA NC YW4L-M2E02Q➂➁ 2: 6V AC/DC PW: pure white Terminal Blocks
3: 12V AC/DC R: red
1NO-1NC NO FA NC YW4L-M2E11Q➂➁
LED 4: 24V AC/DC S: blue Relays & Sockets
1NO NO FA — YW4L-A2E10Q➂➁ H: 110V AC/DC W: white
1NC — FA NC YW4L-A2E01Q➂➁ Circuit
M3: 230/240V AC/DC Y: yellow
Protectors
Maintained 2NO NO FA NO YW4L-A2E20Q➂➁ Built-in LED lamp:
2NC NC FA NC YW4L-A2E02Q➂➁ LSED-➂➁N Power Supplies

1NO-1NC NO FA NC YW4L-A2E11Q➂➁ LED Illumination


1NO NO FA — YW4L-M2E10Q➂➁
1NC — FA NC YW4L-M2E01Q➂➁ Controllers
A: amber
Momentary 2NO NO FA NO YW4L-M2E20Q➂➁ G: green Operator
2NC NC FA NC YW4L-M2E02Q➂➁ R: red Interfaces
5: 6V AC/DC S: blue
1NO-1NC NO FA NC YW4L-M2E11Q➂➁ Sensors
Incandescent 6: 12V AC/DC W: white
1NO NO FA — YW4L-A2E10Q➂➁ 7: 24V AC/DC Y: yellow AUTO-ID
1NC — FA NC YW4L-A2E01Q➂➁ Built-in
Maintained 2NO NO FA NO YW4L-A2E20Q➂➁ incandescent lamp:
2NC NC FA NC YW4L-A2E02Q➂➁ LS-T➂
1NO-1NC NO FA NC YW4L-A2E11Q➂➁
Flush Silhouette
Extended with 1NO NO FA — YW4L-MF2E10Q0➁
Full Shroud 1NC — FA NC YW4L-MF2E01Q0➁ ø16
Momentary 2NO NO FA NO YW4L-MF2E20Q0➁ A: amber
2NC NC FA NC YW4L-MF2E02Q0➁ ø22
G: green
1NO-1NC NO FA NC YW4L-MF2E11Q0➁ 0: without lamp R: red
Without Lamp ø30
1NO NO FA — YW4L-AF2E10Q0➁ 250V AC/DC max. S: blue
1NC — FA NC YW4L-AF2E01Q0➁ W: white Miniature
Y: yellow
Maintained 2NO NO FA NO YW4L-AF2E20Q0➁
Pilot Lights
2NC NC FA NC YW4L-AF2E02Q0➁
1NO-1NC NO FA NC YW4L-AF2E11Q0➁
1NO NO FA — YW4L-MF2E10Q➂➁
1NC — FA NC YW4L-MF2E01Q➂➁ A: amber
Momentary HW
2NO NO FA NO YW4L-MF2E20Q➂➁ G: green
2NC NC FA NC YW4L-MF2E02Q➂➁ 2: 6V AC/DC PW: pure white
TW
3: 12V AC/DC R: red
1NO-1NC NO FA NC YW4L-MF2E11Q➂➁
LED 4: 24V AC/DC S: blue YW
1NO NO FA — YW4L-AF2E10Q➂➁ H: 110V AC/DC W: white
1NC — FA NC YW4L-AF2E01Q➂➁ M3: 230/240V AC/DC Y: yellow
Maintained 2NO NO FA NO YW4L-AF2E20Q➂➁ Built-in LED lamp:
2NC NC FA NC YW4L-AF2E02Q➂➁ LSED-➂➁N
1NO-1NC NO FA NC YW4L-AF2E11Q➂➁
1NO NO FA — YW4L-MF2E10Q➂➁
1NC — FA NC YW4L-MF2E01Q➂➁ A: amber
Momentary 2NO NO FA NO YW4L-MF2E20Q➂➁ G: green
2NC NC FA NC YW4L-MF2E02Q➂➁ R: red
5: 6V AC/DC S: blue
1NO-1NC NO FA NC YW4L-MF2E11Q➂➁
Incandescent 6: 12V AC/DC W: white
1NO NO FA — YW4L-AF2E10Q➂➁ 7: 24V AC/DC Y: yellow
1NC — FA NC YW4L-AF2E01Q➂➁ Built-in
Maintained 2NO NO FA NO YW4L-AF2E20Q➂➁ incandescent lamp:
2NC NC FA NC YW4L-AF2E02Q➂➁ LS-T➂
1NO-1NC NO FA NC YW4L-AF2E11Q➂➁
Note: Specify a lens color code in place of ➁ in the Part No. FA: Full voltage adapter
Specify an operating voltage code in place of ➂ in the Part No.

B-282
Switches & Pilot Lights
ø22 YW Series Switches & Pilot Lights

Illuminated Pushbuttons with Metal Bezel


Package Quantity: 1
Contact Block
Mounting Position ➂ Operating
Style Lamp Operation Contact Part No. ➁ Lens Color Code
Voltage Code
1 2 3
ø40mm Mushroom 1NO NO FA — YW4L-M4E10Q0➁
1NC — FA NC YW4L-M4E01Q0➁
APEM Momentary 2NO NO FA NO YW4L-M4E20Q0➁
A: amber
Switches & 2NC NC FA NC YW4L-M4E02Q0➁ G: green
Pilot Lights 1NO-1NC NO FA NC YW4L-M4E11Q0➁ 0: without lamp R: red
Without Lamp
Control Boxes 1NO NO FA — YW4L-A4E10Q0➁ 250V AC/DC max. S: blue
W: white
Emergency 1NC — FA NC YW4L-A4E01Q0➁
Y: yellow
Stop Switches Maintained 2NO NO FA NO YW4L-A4E20Q0➁
Enabling
Switches 2NC NC FA NC YW4L-A4E02Q0➁
1NO-1NC NO FA NC YW4L-A4E11Q0➁
Safety Products
1NO NO FA — YW4L-M4E10Q➂➁
Explosion Proof 1NC — FA NC YW4L-M4E01Q➂➁ A: amber
Momentary 2NO NO FA NO YW4L-M4E20Q➂➁ G: green
Terminal Blocks
2NC NC FA NC YW4L-M4E02Q➂➁ 2: 6V AC/DC PW: pure white
3: 12V AC/DC R: red
Relays & Sockets 1NO-1NC NO FA NC YW4L-M4E11Q➂➁
LED 4: 24V AC/DC S: blue
Circuit 1NO NO FA — YW4L-A4E10Q➂➁ H: 110V AC/DC W: white
Protectors 1NC — FA NC YW4L-A4E01Q➂➁ M3: 230/240V AC/DC Y: yellow
Power Supplies Maintained 2NO NO FA NO YW4L-A4E20Q➂➁ Built-in LED lamp:
LSED-➂➁N
2NC NC FA NC YW4L-A4E02Q➂➁
LED Illumination
1NO-1NC NO FA NC YW4L-A4E11Q➂➁
Controllers 1NO NO FA — YW4L-M4E10Q➂➁
Operator 1NC — FA NC YW4L-M4E01Q➂➁ A: amber
Interfaces Momentary 2NO NO FA NO YW4L-M4E20Q➂➁ G: green
Sensors 2NC NC FA NC YW4L-M4E02Q➂➁ R: red
5: 6V AC/DC S: blue
1NO-1NC NO FA NC YW4L-M4E11Q➂➁
AUTO-ID Incandescent 6: 12V AC/DC W: white
1NO NO FA — YW4L-A4E10Q➂➁ 7: 24V AC/DC Y: yellow
1NC — FA NC YW4L-A4E01Q➂➁ Built-in
Maintained 2NO NO FA NO YW4L-A4E20Q➂➁ incandescent lamp:
LS-T➂
2NC NC FA NC YW4L-A4E02Q➂➁
Flush Silhouette
1NO-1NC NO FA NC YW4L-A4E11Q➂➁
ø16
Note: Specify a lens color code in place of ➁ in the Part No. FA: Full voltage adapter
ø22 Specify an operating voltage code in place of ➂ in the Part No.

ø30
Dimensions (Illuminated Pushbutton with Metal Bezel)
Miniature Panel Thickness: 0.8 to 6 Contact Block Mounting Position
M3.5 Terminal Screw
Pilot Lights Full-voltage Adapter Gasket 3
1 2
10 10 10

HW M3.5 Terminal Screw 0.3


Contact Block
TW Lock
Extended
Locking Ring
YW
28.6
(Lens Diameter)
ø23.6

41.4

.5
ø29
11.3
30
45.8 19
Lock Lock
Extended with Full Shroud
Mushroom Locking Ring Locking Ring
28.6

28.6
(Lens Diameter)

(Lens Diameter)
ø23.6
41.4

41.4
ø40

.5
ø29
11.3
30 30
45.8 20.5 45.8 19.2
All dimensions in mm.

B-283
ø22 YW Series Switches & Pilot Lights

Switches & Pilot Lights


Selector Switches with Plastic Bezel
Package Quantity: 1
Shape Knob

APEM

Switches &
No. of Contact Contact Block Operator Position Spring Return Pilot Lights
Maintained — —
Positions Configuration Mounting Position L R – from Right
Control Boxes
1 NO ●
1NO Emergency
2 YW1S-2E10 YW1S-21E10 — —
(10) Stop Switches
3
1 Enabling
1NC Switches
2 YW1S-2E01 YW1S-21E01 — —
(01)
3 NC ● Safety Products
1 NO ●
2NO
2 YW1S-2E20 YW1S-21E20 — — Explosion Proof
(20)
3 NO ●
1 NC ● Terminal Blocks
2NC
90° 2 YW1S-2E02 YW1S-21E02 — —
(02) Relays & Sockets
2-Position 3 NC ●
1 NO ● Circuit
1NO-1NC
L R 2 YW1S-2E11 YW1S-21E11 — — Protectors
(11)
3 NC ●
Power Supplies
1 NO ●
3NO
2 NO ● YW1S-2E30 YW1S-21E30 — —
(30) LED Illumination
3 NO ●
1 NC ●
3NC Controllers
2 NC ● YW1S-2E03 YW1S-21E03 — —
(03)
3 NC ● Operator
1 NO ● Interfaces
2NO-1NC
2 NC ● YW1S-2E21 YW1S-21E21 — — Sensors
(21)
3 NO ●
1 NO ● AUTO-ID
1NO-2NC
2 NC ● YW1S-2E12 YW1S-21E12 — —
(12)
3 NC ●
No. of Contact Contact Block Operator Position Spring Return Spring Return Spring Return
Maintained
Positions Configuration Mounting Position L C R from Right from Left Two-Way
1 NO ● Flush Silhouette
2NO
2 YW1S-3E20 YW1S-31E20 YW1S-32E20 YW1S-33E20
(20) ø16
3 NO ●
1
2NO ø22
2 NO ● ● YW1S-3E20N1 YW1S-31E20N1 YW1S-32E20N1 YW1S-33E20N1
(20N1)
3 NO ●
ø30
1 NC
2NC
2 YW1S-3E02 YW1S-31E02 YW1S-32E02 YW1S-33E02
(02) Miniature
3 NC
1 Pilot Lights
2NC
2 NC ● YW1S-3E02N1 YW1S-31E02N1 YW1S-32E02N1 YW1S-33E02N1
(02N1)
3 NC
1 NO ●
1NO-1NC
2 YW1S-3E11 YW1S-31E11 YW1S-32E11 YW1S-33E11
(11)
3 NC HW
1 NC
1NO-1NC
45° 2 YW1S-3E11N1 YW1S-31E11N1 YW1S-32E11N1 YW1S-33E11N1 TW
(11N1)
3-Position 3 NO ●
1 NO ● YW
C 1NO-1NC
L R 2 NC ● YW1S-3E11N2 YW1S-31E11N2 YW1S-32E11N2 YW1S-33E11N2
(11N2)
3
1
1NO-1NC
2 NC ● YW1S-3E11N3 YW1S-31E11N3 YW1S-32E11N3 YW1S-33E11N3
(11N3)
3 NO ●
1
1NO-1NC
2 NO ● ● YW1S-3E11N4 YW1S-31E11N4 YW1S-32E11N4 YW1S-33E11N4
(11N4)
3 NC
1 NO ●
3NO
2 NO ● ● YW1S-3E30 YW1S-31E30 YW1S-32E30 YW1S-33E30
(30)
3 NO ●
1 NC
3NC
2 NC ● YW1S-3E03 YW1S-31E03 YW1S-32E03 YW1S-33E03
(03)
3 NC
1 NO ●
2NO-1NC
2 NC ● YW1S-3E21 YW1S-31E21 YW1S-32E21 YW1S-33E21
(21)
3 NO ●
1 NC
1NO-2NC
2 NO ● ● YW1S-3E12 YW1S-31E12 YW1S-32E12 YW1S-33E12
(12)
3 NC

B-284
Switches & Pilot Lights
ø22 YW Series Switches & Pilot Lights

Selector Switches with Metal Bezel


Package Quantity: 1
Shape Knob

APEM

Switches &
Pilot Lights No. of Contact Contact Block Operator Position Spring Return
Maintained — —
Positions Configuration Mounting Position L R – from Right
Control Boxes
1 NO ●
Emergency 1NO
2 YW4S-2E10 YW4S-21E10 — —
Stop Switches (10)
3
Enabling 1
Switches 1NC
2 YW4S-2E01 YW4S-21E01 — —
(01)
Safety Products 3 NC ●
1 NO ●
2NO
Explosion Proof 2 YW4S-2E20 YW4S-21E20 — —
(20)
3 NO ●
Terminal Blocks 1 NC ●
2NC
90° 2 YW4S-2E02 YW4S-21E02 — —
Relays & Sockets (02)
2-Position 3 NC ●
Circuit 1 NO ●
1NO-1NC
Protectors L R 2 YW4S-2E11 YW4S-21E11 — —
(11)
3 NC ●
Power Supplies
1 NO ●
3NO
2 NO ● YW4S-2E30 YW4S-21E30 — —
LED Illumination (30)
3 NO ●
1 NC ●
Controllers 3NC
2 NC ● YW4S-2E03 YW4S-21E03 — —
(03)
Operator 3 NC ●
Interfaces 1 NO ●
2NO-1NC
Sensors 2 NC ● YW4S-2E21 YW4S-21E21 — —
(21)
3 NO ●
AUTO-ID 1 NO ●
1NO-2NC
2 NC ● YW4S-2E12 YW4S-21E12 — —
(12)
3 NC ●
No. of Contact Contact Block Operator Position Spring Return Spring Return Spring Return
Maintained
Positions Configuration Mounting Position L C R from Right from Left Two-Way
Flush Silhouette 1 NO ●
2NO
2 YW4S-3E20 YW4S-31E20 YW4S-32E20 YW4S-33E20
ø16 (20)
3 NO ●
1
ø22 2NO
2 NO ● ● YW4S-3E20N1 YW4S-31E20N1 YW4S-32E20N1 YW4S-33E20N1
(20N1)
3 NO ●
ø30
1 NC
2NC
2 YW4S-3E02 YW4S-31E02 YW4S-32E02 YW4S-33E02
Miniature (02)
3 NC
Pilot Lights 1
2NC
2 NC ● YW4S-3E02N1 YW4S-31E02N1 YW4S-32E02N1 YW4S-33E02N1
(02N1)
3 NC
1 NO ●
1NO-1NC
2 YW4S-3E11 YW4S-31E11 YW4S-32E11 YW4S-33E11
(11)
HW
3 NC
1 NC
1NO-1NC
TW 45° 2 YW4S-3E11N1 YW4S-31E11N1 YW4S-32E11N1 YW4S-33E11N1
(11N1)
3-Position 3 NO ●
YW 1 NO ●
C 1NO-1NC
L R 2 NC ● YW4S-3E11N2 YW4S-31E11N2 YW4S-32E11N2 YW4S-33E11N2
(11N2)
3
1
1NO-1NC
2 NC ● YW4S-3E11N3 YW4S-31E11N3 YW4S-32E11N3 YW4S-33E11N3
(11N3)
3 NO ●
1
1NO-1NC
2 NO ● ● YW4S-3E11N4 YW4S-31E11N4 YW4S-32E11N4 YW4S-33E11N4
(11N4)
3 NC
1 NO ●
3NO
2 NO ● ● YW4S-3E30 YW4S-31E30 YW4S-32E30 YW4S-33E30
(30)
3 NO ●
1 NC
3NC
2 NC ● YW4S-3E03 YW4S-31E03 YW4S-32E03 YW4S-33E03
(03)
3 NC
1 NO ●
2NO-1NC
2 NC ● YW4S-3E21 YW4S-31E21 YW4S-32E21 YW4S-33E21
(21)
3 NO ●
1 NC
1NO-2NC
2 NO ● ● YW4S-3E12 YW4S-31E12 YW4S-32E12 YW4S-33E12
(12)
3 NC

B-285
ø22 YW Series Switches & Pilot Lights

Switches & Pilot Lights


Dimensions  All dimensions in mm

Selector Switch with Plastic Bezel Selector Switch with Metal Bezel
Panel Thickness: 0.8 to 6 Panel Thickness: 0.8 to 6
Gasket Gasket
10

10
APEM
10

10
0.3 Switches &
M3.5 Terminal Screw 0.5 M3.5 Terminal Screw 90° Pilot Lights
Contact Block 90° Contact Block Lock
Control Boxes
Locking Ring
Locking Ring Emergency

28.6
Stop Switches
Enabling

41.4
Switches
.5
ø29 Safety Products
11.3
11 45.8 24 30 Explosion Proof
45.8 24 2-Position 2-Position Terminal Blocks

45°
45° 45° 45° Relays & Sockets
Lock
Lock
Circuit
Protectors
28.6

28.6
Power Supplies
41.4

41.4
LED Illumination
ø29 .5
ø2 ø29 Controllers
Kn 7.6
30 Dia ob 30 Operator
me
ter Interfaces
3-Position 3-Position
Sensors

AUTO-ID

Contact Block Mounting Position


Selector Switch with Plastic Bezel Selector Switch with Metal Bezel Flush Silhouette

Contact Block Mounting Position Contact Block Mounting Position ø16

2 3 1 2 3 ø22
1
ø30

Miniature

Pilot Lights

HW

TW

YW
C C
L R L R

Operator Position Operator Position

B-286
Switches & Pilot Lights
ø22 YW Series Switches & Pilot Lights

Key Selector Switches (90° 2-Position)


Package Quantity: 1
Part No.
Operator Position
Plastic Bezel Metal Bezel

Contact Contact Block


No. of Positions
Configuration Mounting Position
L R
APEM

Switches &
Pilot Lights
1 NO ●
Control Boxes 1NO
2 YW1K-2AE10 YW4K-2AE10
(10)
Emergency 3
Stop Switches
1
Enabling 1NC
Switches 2 YW1K-2AE01 YW4K-2AE01
(01)
3 NC ●
Safety Products
1 NO ●
2NO
Explosion Proof 2 YW1K-2AE20 YW4K-2AE20
(20)
3 NO ●
Terminal Blocks
1 NC ●
2NC
Relays & Sockets 2 YW1K-2AE02 YW4K-2AE02
(02)
90° 2-position 3 NC ●
Circuit Maintained
Protectors 1 NO ●
1NO-1NC
L R 2 YW1K-2AE11 YW4K-2AE11
Power Supplies (11)
3 NC ●
LED Illumination 1 NO ●
3NO
2 NO ● YW1K-2AE30 YW4K-2AE30
Controllers (30)
3 NO ●
Operator 1 NC ●
Interfaces 3NC
2 NC ● YW1K-2AE03 YW4K-2AE03
(03)
Sensors 3 NC ●
1 NO ●
AUTO-ID 2NO-1NC
2 NC ● YW1K-2AE21 YW4K-2AE21
(21)
3 NO ●
1 NO ●
1NO-2NC
2 NC ● YW1K-2AE12 YW4K-2AE12
Flush Silhouette (12)
3 NC ●
ø16 1 NO ●
1NO
2 YW1K-21BE10 YW4K-21BE10
(10)
ø22 3
1
ø30 1NC
2 YW1K-21BE01 YW4K-21BE01
(01)
Miniature 3 NC ●
1 NO ●
Pilot Lights 2NO
2 YW1K-21BE20 YW4K-21BE20
(20)
3 NO ●
1 NC ●
2NC
2 YW1K-21BE02 YW4K-21BE02
(02)
HW 90° 2-position 3 NC ●
Spring Return from Right 1 NO ●
TW 1NO-1NC
L R 2 YW1K-21BE11 YW4K-21BE11
(11)
YW 3 NC ●
1 NO ●
3NO
2 NO ● YW1K-21BE30 YW4K-21BE30
(30)
3 NO ●
1 NC ●
3NC
2 NC ● YW1K-21BE03 YW4K-21BE03
(03)
3 NC ●
1 NO ●
2NO-1NC
2 NC ● YW1K-21BE21 YW4K-21BE21
(21)
3 NO ●
1 NO ●
1NO-2NC
2 NC ● YW1K-21BE12 YW4K-21BE12
(12)
3 NC ●
• On the spring-returned types, the key can be removed only from the maintained position. On the maintained types, the key can be removed from every position.
Key retained positions are also available. See Part No. Development shown on B-288.
• Each key selector switch is supplied with two identical keys.

B-287
ø22 YW Series Switches & Pilot Lights

Switches & Pilot Lights


Key Selector Switches (45° 3-Position)
Package Quantity: 1
Part No.
Operator Position
Plastic Bezel Metal Bezel

Contact Contact Block


No. of Positions
Configuration Mounting Position
L C R
APEM

Switches &
Pilot Lights
1 NO ●
2NO Control Boxes
2 YW1K-3AE20 YW4K-3AE20
(20)
3 NO ● Emergency
Stop Switches
1
2NO Enabling
2 NO ● ● YW1K-3AE20N1 YW4K-3AE20N1 Switches
(20N1)
3 NO ●
Safety Products
1 NC
2NC
2 YW1K-3AE02 YW4K-3AE02 Explosion Proof
(02)
3 NC
Terminal Blocks
1
2NC
2 NC ● YW1K-3AE02N1 YW4K-3AE02N1 Relays & Sockets
(02N1)
3 NC
Circuit
1 NO ● Protectors
1NO-1NC
2 YW1K-3AE11 YW4K-3AE11
(11) Power Supplies
3 NC
1 NC LED Illumination
1NO-1NC
2 YW1K-3AE11N1 YW4K-3AE11N1
45° 3-position (11N1) Controllers
3 NO ●
Maintained
1 NO ● Operator
C 1NO-1NC Interfaces
L R 2 NC ● YW1K-3AE11N2 YW4K-3AE11N2
(11N2)
3 Sensors
1
1NO-1NC AUTO-ID
2 NC ● YW1K-3AE11N3 YW4K-3AE11N3
(11N3)
3 NO ●
1
1NO-1NC
2 NO ● ● YW1K-3AE11N4 YW4K-3AE11N4
(11N4) Flush Silhouette
3 NC
1 NO ● ø16
3NO
2 NO ● ● YW1K-3AE30 YW4K-3AE30
(30)
3 NO ● ø22
1 NC
3NC ø30
2 NC ● YW1K-3AE03 YW4K-3AE03
(03)
3 NC Miniature
1 NO ●
2NO-1NC Pilot Lights
2 NC ● YW1K-3AE21 YW4K-3AE21
(21)
3 NO ●
1 NC
1NO-2NC
2 NO ● ● YW1K-3AE12 YW4K-3AE12
(12)
3 NC HW

• On the maintained types, the key can be removed from every position. Key retained positions are also available. See Part No. Development below. TW
• Each key selector switch is supplied with two identical keys.
YW

Part No. Development Contact Block Mounting Position


YW1K-2 A E21 Contact Block
Key removal position code Mounting Position
2-position 1 2 3
A: Removable in all positions
B: Removable in left only
C: Removable in right only C
L R
3-position
A: Removable in all positions
B: Removable in left and center Operator Position
C: Removable in right and center
D: Removable in center only
E: Removable in right and left
G: Removable in left only
H: Removable in right only

B-288
Switches & Pilot Lights
ø22 YW Series Switches & Pilot Lights

Key Selector Switches (45° 3-Position)


Package Quantity: 1
Part No.
Operator Position
Plastic Bezel Metal Bezel

Contact Contact Block


No. of Positions
Configuration Mounting Position
L C R
APEM

Switches &
Pilot Lights
1 NO ●
Control Boxes 2NO
2 YW1K-31BE20 YW4K-31BE20
(20)
Emergency 3 NO ●
Stop Switches
1
Enabling 2NO
Switches 2 NO ● ● YW1K-31BE20N1 YW4K-31BE20N1
(20N1)
3 NO ●
Safety Products
1 NC
2NC
Explosion Proof 2 YW1K-31BE02 YW4K-31BE02
(02)
3 NC
Terminal Blocks
1
2NC
Relays & Sockets 2 NC ● YW1K-31BE02N1 YW4K-31BE02N1
(02N1)
3 NC
Circuit
Protectors 1 NO ●
1NO-1NC
2 YW1K-31BE11 YW4K-31BE11
Power Supplies (11)
3 NC
LED Illumination 1 NC
1NO-1NC
2 YW1K-31BE11N1 YW4K-31BE11N1
Controllers 45° 3-position (11N1)
3 NO ●
Spring Return from Right
Operator 1 NO ●
Interfaces C 1NO-1NC
L R 2 NC ● YW1K-31BE11N2 YW4K-31BE11N2
(11N2)
Sensors 3
1
AUTO-ID 1NO-1NC
2 NC ● YW1K-31BE11N3 YW4K-31BE11N3
(11N3)
3 NO ●
1
1NO-1NC
2 NO ● ● YW1K-31BE11N4 YW4K-31BE11N4
Flush Silhouette (11N4)
3 NC
ø16 1 NO ●
3NO
2 NO ● ● YW1K-31BE30 YW4K-31BE30
(30)
ø22 3 NO ●
1 NC
ø30 3NC
2 NC ● YW1K-31BE03 YW4K-31BE03
(03)
Miniature 3 NC
1 NO ●
Pilot Lights 2NO-1NC
2 NC ● YW1K-31BE21 YW4K-31BE21
(21)
3 NO ●
1 NC
1NO-2NC
2 NO ● ● YW1K-31BE12 YW4K-31BE12
(12)
HW 3 NC

TW • On the spring-returned types, the key can be removed only from the maintained position.
Key retained positions are also available. See Part No. Development shown on B-288.
YW • Each key selector switch is supplied with two identical keys.

B-289
ø22 YW Series Switches & Pilot Lights

Switches & Pilot Lights


Key Selector Switches (45° 3-Position)
Package Quantity: 1
Part No.
Operator Position
Plastic Bezel Metal Bezel

Contact Contact Block


No. of Positions
Configuration Mounting Position
L C R
APEM

Switches &
Pilot Lights
1 NO ●
2NO Control Boxes
2 YW1K-32CE20 YW4K-32CE20
(20)
3 NO ● Emergency
Stop Switches
1
2NO Enabling
2 NO ● ● YW1K-32CE20N1 YW4K-32CE20N1 Switches
(20N1)
3 NO ●
Safety Products
1 NC
2NC
2 YW1K-32CE02 YW4K-32CE02 Explosion Proof
(02)
3 NC
Terminal Blocks
1
2NC
2 NC ● YW1K-32CE02N1 YW4K-32CE02N1 Relays & Sockets
(02N1)
3 NC
Circuit
1 NO ● Protectors
1NO-1NC
2 YW1K-32CE11 YW4K-32CE11
(11) Power Supplies
3 NC
1 NC LED Illumination
1NO-1NC
2 YW1K-32CE11N1 YW4K-32CE11N1
45° 3-position (11N1) Controllers
3 NO ●
Spring Return from Left
1 NO ● Operator
C 1NO-1NC Interfaces
L R 2 NC ● YW1K-32CE11N2 YW4K-32CE11N2
(11N2)
3 Sensors
1
1NO-1NC AUTO-ID
2 NC ● YW1K-32CE11N3 YW4K-32CE11N3
(11N3)
3 NO ●
1
1NO-1NC
2 NO ● ● YW1K-32CE11N4 YW4K-32CE11N4
(11N4) Flush Silhouette
3 NC
1 NO ● ø16
3NO
2 NO ● ● YW1K-32CE30 YW4K-32CE30
(30)
3 NO ● ø22
1 NC
3NC ø30
2 NC ● YW1K-32CE03 YW4K-32CE03
(03)
3 NC Miniature
1 NO ●
2NO-1NC Pilot Lights
2 NC ● YW1K-32CE21 YW4K-32CE21
(21)
3 NO ●
1 NC
1NO-2NC
2 NO ● ● YW1K-32CE12 YW4K-32CE12
(12)
3 NC HW

• On the spring-returned types, the key can be removed only from the maintained position. TW
Key retained positions are also available. See Part No. Development shown on B-288.
• Each key selector switch is supplied with two identical keys. YW

B-290
Switches & Pilot Lights
ø22 YW Series Switches & Pilot Lights

Key Selector Switches (45° 3-Position)


Package Quantity: 1
Part No.
Operator Position
Plastic Bezel Metal Bezel

Contact Contact Block


No. of Positions
Configuration Mounting Position
L C R
APEM

Switches &
Pilot Lights
1 NO ●
Control Boxes 2NO
2 YW1K-33DE20 YW4K-33DE20
(20)
Emergency 3 NO ●
Stop Switches
1
Enabling 2NO
Switches 2 NO ● ● YW1K-33DE20N1 YW4K-33DE20N1
(20N1)
3 NO ●
Safety Products
1 NC
2NC
Explosion Proof 2 YW1K-33DE02 YW4K-33DE02
(02)
3 NC
Terminal Blocks
1
2NC
Relays & Sockets 2 NC ● YW1K-33DE02N1 YW4K-33DE02N1
(02N1)
3 NC
Circuit
Protectors 1 NO ●
1NO-1NC
2 YW1K-33DE11 YW4K-33DE11
Power Supplies (11)
3 NC
LED Illumination 1 NC
1NO-1NC
2 YW1K-33DE11N1 YW4K-33DE11N1
Controllers 45° 3-position (11N1)
3 NO ●
Spring Return Two-way
Operator 1 NO ●
Interfaces C 1NO-1NC
L R 2 NC ● YW1K-33DE11N2 YW4K-33DE11N2
(11N2)
Sensors 3
1
AUTO-ID 1NO-1NC
2 NC ● YW1K-33DE11N3 YW4K-33DE11N3
(11N3)
3 NO ●
1
1NO-1NC
2 NO ● ● YW1K-33DE11N4 YW4K-33DE11N4
Flush Silhouette (11N4)
3 NC
ø16 1 NO ●
3NO
2 NO ● ● YW1K-33DE30 YW4K-33DE30
(30)
ø22 3 NO ●
1 NC
ø30 3NC
2 NC ● YW1K-33DE03 YW4K-33DE03
(03)
Miniature 3 NC
1 NO ●
Pilot Lights 2NO-1NC
2 NC ● YW1K-33DE21 YW4K-33DE21
(21)
3 NO ●
1 NC
1NO-2NC
2 NO ● ● YW1K-33DE12 YW4K-33DE12
(12)
HW 3 NC

TW • On the spring-returned types, the key can be removed only from the maintained position.
Key retained positions are also available. See Part No. Development shown on B-288.
YW • Each key selector switch is supplied with two identical keys.

B-291
ø22 YW Series Switches & Pilot Lights

Switches & Pilot Lights


Dimensions  All dimensions in mm

Plastic Bezel Metal Bezel

Panel Thickness 0.8 to 6 Panel Thickness 0.8 to 6


Gasket Gasket

APEM

M3.5 Terminal Screw 0.5 Switches &


M3.5 Terminal Screw 0.3
Contact Block Pilot Lights
Contact Block
90° 90° Control Boxes

Emergency
Locking Ring Locking Ring Stop Switches
Enabling
Switches

Safety Products

Explosion Proof
11 11.3
2-position Terminal Blocks
45.8 38 45.8 38 2-position
Relays & Sockets

Circuit
45°
45° 45°
45° Protectors
Lock Lock
Power Supplies
28.6

28.6
LED Illumination

Controllers
41.4

41.4
.5
ø29
.0 ø29 Operator
Interfaces

30.0 Sensors
30.0
3-position 3-position
AUTO-ID

Contact Block Mounting Position Flush Silhouette


Plastic Bezel Metal Bezel
ø16

Contact Block Mounting Position Contact Block Mounting Position ø22

2 3 1 2 3 ø30
1
Miniature

Pilot Lights

HW

TW

YW

C C
L R L R

Operator Position Operator Position

B-292
Switches & Pilot Lights
ø22 YW Series Switches & Pilot Lights

Accessories
Package
Name & Shape Part No. Description & Dimensions (mm)
Quantity
Locking Ring Wrench Metallic tool used to tighten the plastic locking ring
when installing the YW series in a panel.
110 8
MW9Z-T1 ø2 1
APEM

Switches &
Pilot Lights
Lamp Holder Tool Made of rubber. Used for replacing lamps.
Control Boxes

ø14
Emergency OR-55 1
Stop Switches
Enabling 59

ø11.6
Switches

Safety Products
Rubber Mounting Hole Plug Used for plugging unused mounting holes in the panel. ø29

Explosion Proof
Color: Black
OB-31PN05 5

3.5
Terminal Blocks ø25

3.5
Relays & Sockets
Metallic Mounting Hole Plug Used for plugging unused mounting holes in the panel.
Circuit Weight: Approx. 18g ø25.8
Protectors

3
LW9Z-BM 1
Power Supplies

12
Locking Ring
LED Illumination

Controllers Anti-Rotation Ring Prevents rotation of switches in panel.


1.5 TOP
Mainly used with selector switches
Operator ø29
when no nameplate is used.
Interfaces HW9Z-RLPN10 ø22 10
With waterproof gasket (IP65).
Sensors Made of plastic (black).
Applicable panel thickness: 1.2 to 4.5 mm
AUTO-ID
Padlock Cover Plastic hinged cover to protect pushbuttons, 82.5
illuminated pushbuttons, or selector switches. Panel Thickness 0.8 to 3.2
Degree of protection: IP65.
Applicable panel thickness: 0.8 to 3.2 mm
Flush Silhouette
R6
6.5

93
ø16
HW9Z-KL1 1
ø22
30
70

ø30 24
0
ø5
ø2
2.2

Miniature Waterproof Gasket


Pad Lock Hole ø8 29.5 Thickness 0.5
Pilot Lights 30

HW

TW

YW

B-293
ø22 YW Series Switches & Pilot Lights

Switches & Pilot Lights


Maintenance Parts
Package
Name & Shape Part No. Description & Dimensions (mm)
Quantity
Single Contact Block

YW-E10 Contact: 1NO Color: blue


APEM

5
Switches &
Pilot Lights

22.3
10
Control Boxes
M3.5 41.4
Terminal Screw Emergency
YW-E01 Contact: 1NC Color: reddish purple Stop Switches
Enabling
Switches

Safety Products
Double Contact Block
Explosion Proof

Terminal Blocks
YW-EW20 Contact: 2NO Color: blue
Relays & Sockets

Circuit
Protectors

5
Power Supplies

LED Illumination

42.3
Controllers
YW-EW02 Contact: 2NC Color: reddish purple 10
M3.5 Operator
Terminal Screw 41.4 Interfaces

Sensors

Note: D
 ouble contact blocks cannot be used on AUTO-ID
emergency stop switches.

Color: blue
‌ and reddish
YW-EW11 Contact: 1NO-1NC
purple
Flush Silhouette

ø16

LED Lamp Specify a color code in place of ➁ in the Part No.: ø22
LSED-6➁N 6V AC/DC
A (amber), G (green), PW (pure white), R (red), S (blue), Y (yellow)
See B-271 for applicable units and rated current. ø30
LSED-1➁N 12V AC/DC Note: ‌Yellow LED lamps are used for white illumination of pilot lights and
illuminated pushbuttons. Miniature

LSED-2➁N 24V AC/DC BA9S/14


4.2
1 Pilot Lights
10.1

LSED-H➁N 110V AC/DC

5.4 14.6 HW
LSED-M3➁N 230/240V AC/DC
TW
Incandescent Lamp One pack contains 100 incandescent lamps.
LS-T6P 6.3V, 1W
YW
Base BA9S/13

LS-T8P 18V, 1W 100


ø11 ±1

LS-T3P 30V, 1W 23 ±1

Spare Key

YW9Z-SK00PN02 2
BA9S/14
10.1

5.4 14.6

B-294
Switches & Pilot Lights
ø22 YW Series Switches & Pilot Lights

Maintenance Parts
Buttons, Lenses, and Marking Plates
➀➁ Package
Name Style Part No. Dimensions (mm)
Color Code Quantity
Button 3.6
ø2
(for pushbuttons)
APEM Extended YW9Z-B12➀PN10
Switches & B: black 9.3
Pilot Lights G: green
R: red 0
Control Boxes ø4 10
S: blue
Emergency W: white

ø23.6
Stop Switches
Mushroom ø40mm YW9Z-B14➀PN10 Y: yellow
Enabling
Switches
6
Safety Products 10.8

Explosion Proof Lens A: amber


(for pilot lights) C: clear 9.8
ø2
Terminal Blocks G: green
Flush YW9Z-PL11➁PN10 R: red 10
Relays & Sockets S: blue
Circuit W: white 8.5
Protectors Y: yellow
Power Supplies
A: amber 9.8
ø2
LED Illumination
C: clear
G: green
Flush Marking YW9Z-PL11B➁PN10 10
Controllers R: red
S: blue
Operator Y: yellow 9
Interfaces

Sensors 9.8
ø2

AUTO-ID Extended YW9Z-PL12T➁PN10 10


A: amber
C: clear
G: green 14.5
R: red
S: blue 9.
8
Flush Silhouette ø2
W: white
Dome YW9Z-PL12➁PN10 Y: yellow 10
ø16

ø22 14.5

ø30 Lens 3.6


(for illuminated pushbuttons) ø2
Miniature Extended YW9Z-L12➁PN10
Pilot Lights A: amber 9.3
C: clear
G: green
ø4
0 10
R: red
S: blue
ø23.6

HW Y: yellow
Mushroom ø40mm YW9Z-L14➁PN10
TW
6
10.8
YW
Marking Plate
2.7

(for pilot lights)


ø2

ø21.8

— YW9Z-PP12PN10 — 10

21 2
4.4

Marking Plate
2
7.

(for illuminated pushbuttons)


ø1

— YW9Z-P12PN10 — 10
ø16

15.2 1.4
5

B-295
ø22 YW Series Switches & Pilot Lights

Switches & Pilot Lights


Nameplates
HWAM, HWAQ, HWAS, and HWAV
Package
Name Legend Material Part No. Ordering No. Dimensions (mm)
Quantity

29 Marking Plate
1 27 2.7
HWAM
APEM

12.1
Order marking plate Plastic (black)
HWAM HWAM

30
Switches &
separately. 1.5 mm thick R14.9

14.5 14.9
Pilot Lights

HWAMPN10 10 ø22 Control Boxes


1.5 1
Emergency
Stop Switches
29 Enabling
Marking Plate
Switches
HWAQ 1 27 2.7
Safety Products

12.1
Order marking plate Plastic (black)
HWAQ HWAQ

30
separately. 1.5 mm thick R14.9 Explosion Proof

14.5 14.9
HWAQPN10 10 ø22 Terminal Blocks
1.9 1
Relays & Sockets

45
Circuit
1.6 0.9
Protectors
HWAS-0 1
Power Supplies
Plastic (black)
HWAQ Blank HWAS-0
1.5 mm thick LED Illumination

10 ø22
HWAS-0PN10 Controllers

Operator
Interfaces
R G E NC Y
EME Sensors
ø60
Blank HWAV-0 HWAV-0 1
AUTO-ID

Plastic (yellow)
HWAV ø22
1.5 mm thick
STOP
1.6 0.9
EMERGENCY STOP HWAV-27 HWAV-27 1 Flush Silhouette
• Legend “Emergency Stop”
is indicated outside a ø44mm circle. ø16

ø22

Making Plate ø30


Description Material Part No. Ordering No. Package Quantity Dimensions (mm)
Miniature
White legend on black background.
HWNP-∗ 1 Pilot Lights
Aluminum (black) 27
HWNP HWNP-∗
1.0 mm thick
HWNP-∗PN10 10
12

• Specify a legend code in place of ∗ in the Ordering No. HW

TW
Legends
• Installing the marking plate YW
Code Legend • To remove the marking plate, insert the flat screwdriver beween
on a nameplate the marking plate and nameplate.
0 (blank)
1 ON
Nameplate
2 OFF ➁ Flat Screwdriver
Marking Plate

3 START Marking Plate


4 STOP When requring no anti-rotation, remove the projection using pliers.
31 OFF-ON ➀
Nameplate
35 HAND-AUTO
53 HAND-OFF-AUTO
Note: When using an nameplate, the mounting panel thickness is decreased by 1.5 mm.

B-296
Switches & Pilot Lights
ø22 YW Series Switches & Pilot Lights

Switch Guards
 Package Quantity: 1
Part No. & Shape (mm) Dimensions Part No. & Shape Dimensions (mm)
HW9Z-KG1 HW9Z-KG4
38 35 (0.4)
64 50

ø2
22

2
47
ø2
2
APEM

ø90
Switches &

76

67
ø66.8

ø80
32
Pilot Lights ø41
Gasket
EMO Switch Guard EMO Switch Guard
Control Boxes SEMI S2 compliant (Note 1) SEMI S2 compliant (Note 1)
Emergency SEMATECH compliant (Note 3) (2.2)
Stop Switches ISO 13850 compliant
Enabling
Switches HW9Z-KG2 HW9Z-KG5 75 36.2 (0.2)
36.5 63 0
Safety Products ø9
ø2
2.2

Explosion Proof ø2
2
ø76.1

Terminal Blocks

ø76

ø90
EMO Switch Guard
Relays & Sockets EMO Switch Guard Gasket
SEMI S2 compliant (Note 1)
SEMI S2 compliant (Note 2)
Circuit SEMATECH compliant (Note 3)
SEMATECH compliant (Note 3) (2.0)
Protectors
ISO 13850 compliant
Power Supplies
HW9Z-KG3 Material: Polyamide (PA6)
42 35 (0.4)
LED Illumination Color: Yellow, Munsell 2.5Y 8/10 equivalent
ø2
2 Degree of protection: IP65
Controllers
• Degree of protection IP65 applies to the combination of an emergency stop
Operator switch and an EMO switch guard.
ø64

ø74
52

Interfaces
ø37 Note 1: SEMI S2-0703 12.5.1 compliant.
EMO Switch Guard Gasket
Sensors
Note 2: The combination of IDEC’s emergency stop switches and EMO switch
SEMI S2 compliant (Note 1) (2.2) guards are approved by TÜV Rheinland for compliance with SEMI S2
AUTO-ID ISO 13850 compliant
standard.
Note 3: SEMATECH Application Guide for SEMI S2-93, 12.4.c. compliant.

Transformer
Flush Silhouette

ø16
Din Rail Mount Transformer For 6V
Dimensions (mm)
ø22
Secondary Terminal Primary Terminal
ø30 Screws M3.5 Screws M3.5

Miniature

Pilot Lights
22
30

Primary Voltage 2-ø3.5 40


Part No. Applicable Lamp Rating Mounting Holes 48
(50/60 Hz)
HW
110V AC TWR516 One full voltage type illuminated unit 52
TW 115V AC TWR5116 containing LED lamp LSED-6N (6V AC/
120V AC TWR5126 DC) or incandescent lamp LS-T6 (6.3V)
YW
220V AC TWR526
41
40

230V AC TWR5236
240V AC TWR5246
380V AC TWR5386
440V AC TWR546
480V AC TWR5486 Note: Finger-safe terminal cover is supplied with the transformer.

Accessories When ordering, specify the Ordering No.


Shape Material Part No. Ordering No. Package Quantity Dimensions (mm)
Length: 1000 mm
DIN 35 mm Rail Aluminum BAA1000 BAA1000PN10 10
Weight: 200g approx.
Applicable rail: BAA1000
End Clip Metal (zinc-plated steel) BNL6 BNL6PN10 10
Weight: 15g approx.
• See H-071 for DIN rail products.

B-297
ø22 YW Series Switches & Pilot Lights

Switches & Pilot Lights


Safety Precautions
• Turn off the power to the YW series before starting installation, • For wiring, use wires of a proper size to meet the voltage and current
removal, wiring, maintenance, and inspection of the products. Failure requirements. Tighten the M3.5 terminal screws to a tightening
to turn power off may cause electrical shocks or fire hazard. torque of 1.0 N·m. Failure to tighten the terminal screws may cause
• To avoid burning your hand, use the lamp holder tool when replacing overheating and fire.
lamps.
APEM

Instructions Switches &


Pilot Lights

Panel Mounting 2. To reinstall, place the TOP markings on the operator and the latch on the full Control Boxes
voltage unit in the same direction, and insert the operator into the full voltage Emergency
• Remove the contact block from the operator (for pilot lights, remove the
unit. Stop Switches
transformer or full voltage unit from the pilot light). Remove the locking ring
from the operator. Insert the operator into the panel cut-out from the front, Enabling
Notes for Panel Mounting Switches
tighten the locking ring from the back, then install the contact block to the
1. Use the optional locking ring wrench (MW9Z-T1) to mount the operator onto Safety Products
operator. a panel. Tightening torque must not exceed 2.0 N·m. Do not use pliers.
Removing and Installing the Contact Block Excessive tightening will damage the locking ring. Explosion Proof
2. For contact blocks and transformers housing LED and incandescent lamps,
make sure not to press the lamps too hard, otherwise the lamp socket may Terminal Blocks
be damaged.
Relays & Sockets
Insertion Order of Lens and Marking Plate Circuit
Illuminated Pushbutton Pilot Light Protectors

Extended Power Supplies


Flush
Extended
Dome LED Illumination
➂ Pull out the contact block
➀ Pull up the locking lever. Controllers
Marking Plate Lens
➁ Turn the lever to the left.
Lens Operator
Interfaces
1. To remove the operator from the contact block, pull up the locking lever and Flush Marking
With Full Shroud
turn it to the left. Then the operator can be pulled out. Sensors
2. To reinstall, place the TOP marking on the operator and the TOP marking
on the contact block mounting adapter in the same direction, and insert the AUTO-ID
Marking Plate
operator into the contact block mounting adapter. Then turn the locking lever Marking Plate
Lens
to the right.
Lens
Full Shroud

Mushroom Flush Silhouette

ø16

ø22
Marking Plate
Lens ø30

Marking Miniature
Removing and Installing the Transformer For YW series pilot lights and illuminated pushbuttons, legends and symbols can
1. Insert a flat screwdriver (5 mm wide at maximum) into the latch hole on the Pilot Lights
be engraved on built-in marking plates, or printed mylar film can be inserted
transformer unit as shown in the photo below, and disengage the latch. Then under the lens for labeling purposes. Mylar film is not supplied with the YW
pull out the operator. series and must be supplied by the end user.
2. To reinstall, place the TOP marking on the operator and the latch in the same
Built-in Marking Plate and Marking Film Size
direction, and push the operator into the transformer.
HW
Unit Pilot Light Illuminated Pushbutton
➀ TW
1.0
ø2 5.2
ø1
YW
Built-in Marking Plate

Engraving Area Engraving Area


1.2
1.0

Removing the Full Voltage Unit


Engraving depth: 0.5 mm maximum
Marking plate material: White acrylic

-0.2
-0.2
Applicable Marking Film

0
0

ø17.2
ø22.7


0
20.8
0
-0.2
15.0 -0.2

1. To remove the full voltage unit, squeeze the full voltage unit from both sides
to disengage the latch as shown, and pull it out. Like the transformer unit, 0.1-mm-thick × 2 sheets or 0.2-mm-thick × 1 sheet
the full voltage unit can also be pulled out by inserting a flat screwdriver into Film material: Mylar (recommended)
the latch hole as shown. Note: Marking film is not supplied with the pilot light or illuminated pushbutton.

B-298
Switches & Pilot Lights
ø22 YW Series Switches & Pilot Lights

Instructions
Replacement (LED and incandescent lamps) Mounting Panel Thickness
Lamps can be replaced using the lamp holder tool (OR-55) from the front of the The mounting panel must be 0.8 to 6.0 mm in thickness. When optional
panel, or by removing the contact block from the operator unit. accessories are added, the applicable panel thickness changes as shown below.
Padlock Cover
Removing the Lamp from the Front of the Panel HW9Z-KL1P

APEM

Switches &
Pilot Lights

Control Boxes

Emergency
Stop Switches
Enabling Panel Thickness Panel Thickness
Switches To remove, gently insert the lamp holder tool onto the lamp head. Then push 0.8 to 6 mm 0.8 to 3.2 mm
slightly, and turn the lamp holder tool to the left.
Safety Products
Wiring
Explosion Proof
Installing the Lamp from the Front of the Panel Applicable Wires
1. To install, insert the lamp head into the lamp holder tool, and hold the lamp
Stranded wire: 2.0 mm2 maximum (14AWG)
Terminal Blocks as shown in the figure below. Solid wire: ø1.6 mm maximum (16AWG)
Relays & Sockets Lamp Lamp Removal Tool One or two wires can be connected to the terminal.
Circuit
Protectors Applicable Crimping Terminals
Power Supplies [Spade terminal]
When using crimping terminals, be sure to use insulating tubes or use insulated
LED Illumination
2. Place the pins on the lamp base to the grooves in the lamp socket. Insert the crimping terminals.
lamp and turn it to the right.
Note: Ring terminals cannot be used.
Controllers
11.5 max. Crimping Terminal Insulation Tube
Operator
6.9 max.
3.6 min.

Interfaces 8.1 max. Wire

Sensors

AUTO-ID 0.5 min.


Pilot Light Illuminated Pushbutton
[Ferrule]
Note: LED lamps in unibody pilot lights cannot be replaced.
When connecting two ferrules to one terminal, use ferrules without insulation.
Flush Silhouette Removing Contact Blocks and Full Voltage Adapters
1.7 max.
1.7 max.

Insert a flat screwdriver between the latch and contact block mounting adapter, Insulation
ø16
and disengage the latch.
ø22
Make sure to remove the lamp and contact blocks before removing the full
voltage adapter. 8.0 max. 8.0 max.
ø30
Lamp
Miniature When using spade terminals or ferrules, insert them to the bottom.
Pilot Lights
1
[Solid Wire]
Full Voltage Adapter When connecting two wires directly, use wires of the same size.
ø1.6 max.

Contact Block
HW
3
TW

8.0 max.
YW
2 2

Tightening Torque for Terminal Screws


Tighten terminal screws to a torque of 1.0 N·m. Contact Bounce
When pressing or turning the operator, the NC and NO contacts will
bounce. When designing a control circuit, take the contact bounce time into
Anti-rotation Ring and Mounting Panel consideration (reference value: 20 ms).
Turn the TOP marking on the operator and the ▲ mark on the anti-rotation ring
to the recess on the mounting panel.
Projections (p mark)

Anti-rotation Ring Locking Ring

Panel Thickness 1.2 to 4.5 mm

B-299
ø22 YW Series Switches & Pilot Lights

Switches & Pilot Lights


Instructions
Precautions for Noise Nameplate Projection

When using the unibody pilot light in an environment where it is When anti-rotation is not required, remove the
subjected to noise, connect a noise suppressor across terminals X1 projection from the nameplate using pliers.
and X2 as shown below.
Noise Suppressor
Nameplate
X2 APEM
Handling
Switches &
X1 Do not expose the switch to excessive shock and Pilot Lights
vibration, otherwise the switch may be deformed
or damaged, causing malfunction or operation Control Boxes

Key Selector Switch failure. Emergency


Stop Switches
Before operation, ensure that the key is inserted into the key hole
Enabling
completely. Operating the key selector switch with a loose key will Switches
cause damage to the key selector switch.
Safety Products

LED Illumination [Protection Example 1] For AC circuit Explosion Proof

LED lamps consist of semiconductors. If the applied voltage exceeds Terminal Blocks
the rated voltage, LED elements deteriorate due to overheat, resulting LED with
transformer Relays & Sockets
in significant decrease in brightness, hue change, or failure of lighting.
Also, if extraneous noise, transient voltage, or transient current is C C Circuit
applied to the circuit, similar effects will be caused. When using LED LED with Relay Ry Protectors
LED
transformer LED R coil or R
lamps, observe the following instructions. solenoid Power Supplies

Rated Voltage LED Illumination


The LED illuminated units are rated at 6V, 12V, 24V, 110V, or 230/240V [Protection Example 2] For DC circuit
Controllers
AC/DC, and can be used within ±10% the rated voltage of either AC +
or DC, except the 230/240V AC/DC types can be used on 250V AC/DC Operator
Interfaces
maximum.
Sensors
DC Power
1. Switching power supply Relay Ry LED Diode AUTO-ID
coil or
Regulated voltage from a switching power supply is best suited. solenoid
Make sure to use within the rated voltage of the LED lamp. –

2. Rechargeable battery
Note that the battery voltage may exceed the rated voltage of the Countermeasures against Dim Lighting
Flush Silhouette
LED lamp while the battery is being charged and immediately after 1. Leakage current through transistors or a contact protection circuit
the charging is complete. Be sure to use the LED lamp on a voltage may cause the LED lamp to illuminate dimly even when the output ø16
of ±10% the rated voltage, except the 230/240V AC/DC types on is off.
ø22
250V AC/DC maximum. 2. When the LED lamp is illuminated by a transistor output, take the
3. Full-wave rectification following measure. ø30
Since the LED lamp is AC/DC compatible, a diode bridge for
rectification is not necessary. If the LED lamp is used on a full-wave Miniature
[Circuit Example]
rectification current through a diode bridge, the rectifier diodes will Connect shunt resistor R in parallel with the LED lamp. Pilot Lights
reduce the voltage, resulting in lower brightness.
4. Single-phase half-wave rectification
This is not suitable for the power source of LED lamps. Use
constant- voltage DC power. R LED
HW
Noise
Io TW
LED elements deteriorate due to extraneous noise, resulting in
significant decrease in brightness, hue change, or failure of lighting. Io: Leakage current when the output is off
YW
R: Shunt resistor
When such effects are anticipated, take a protection measure shown
below, such as RC elements or a surge absorber.

Ordering Information
• When ordering, specify the Part No. and quantity.
• Replacement contact blocks are supplied in a package containing 10
pieces.

SAPEN01A_B YW June 2023

B-300
Ordering Terms and Conditions
Thank you for using IDEC Products.
By purchasing products listed in our catalogs, datasheets, and the like (hereinafter referred to as “Catalogs”) you agree to be bound by these terms and conditions. Please read
and agree to the terms and conditions before placing your order.

1. Notes on contents of Catalogs 3. Inspections


(1) Rated values, performance values, and specification values of IDEC products We ask that you implement inspections for IDEC products you purchase without
listed in this Catalog are values acquired under respective conditions in delay, as well as thoroughly keep in mind management/maintenance regarding
independent testing, and do not guarantee values gained in combined handling of the product before and during the inspection.
conditions.
Also, durability varies depending on the usage environment and usage
4. Warranty
conditions. (1) Warranty period
(2) Reference data and reference values listed in Catalogs are for reference The warranty period for IDEC products shall be one (1) year after purchase or
purposes only, and do not guarantee that the product will always operate delivery to the specified location. However, this shall not apply in cases where
appropriately in that range. there is a different specification in the Catalogs or there is another agreement
(3) The specifications / appearance and accessories of IDEC products listed in in place between you and IDEC.
Catalogs are subject to change or termination of sales without notice, for (2) Warranty scope
improvement or other reasons. Should a failure occur in an IDEC product during the above warranty period
(4) The content of Catalogs is subject to change without notice. for reasons attributable to IDEC, then IDEC shall replace or repair that
product, free of charge, at the purchase location / delivery location of the
2. Note on applications product, or an IDEC service base. However, failures caused by the following
(1) If using IDEC products in combination with other products, confirm the reasons shall be deemed outside the scope of this warranty.
applicable laws / regulations and standards. i. The product was handled or used deviating from the conditions /
Also, confirm that IDEC products are compatible with your systems, machines, environment listed in the Catalogs
devices, and the like by using under the actual conditions. IDEC shall bear no
ii. The failure was caused by reasons other than an IDEC product
liability whatsoever regarding the compatibility with IDEC products.
iii. Modification or repair was performed by a party other than IDEC
(2) The usage examples and application examples listed in Catalogs are for
reference purposes only. Therefore, when introducing a product, confirm the iv. The failure was caused by a software program of a party other than
performance and safety of the instruments, devices, and the like before use. IDEC
Furthermore, regarding these examples, IDEC does not grant license to use v. The product was used outside of its original purpose
IDEC products to you, and IDEC offers no warranties regarding the ownership vi. Replacement of maintenance parts, installation of accessories, or the like
of intellectual property rights or non-infringement upon the intellectual was not performed properly in accordance with the user’s manual and
property rights of third parties. Catalogs
(3) When using IDEC products, be cautious when implementing the following. vii. The failure could not have been predicted with the scientific and
i. Use of IDEC products with sufficient allowance for rating and technical standards at the time when the product was shipped from
performance IDEC
ii. Safety design, including redundant design and malfunction prevention viii. The failure was due to other causes not attributable to IDEC (including
design that prevents other danger and damage even in the event that an cases of force majeure such as natural disasters and other disasters)
IDEC product fails Furthermore, the warranty described here refers to a warranty on the IDEC
iii. Wiring and installation that ensures the IDEC product used in your product as a unit, and damages induced by the failure of an IDEC product are
system, machine, device, or the like can perform and function according excluded from this warranty.
to its specifications 5. Limitation of liability
(4) Continuing to use an IDEC product even after the performance has The warranty listed in this Agreement is the full and complete warranty for IDEC
deteriorated can result in abnormal heat, smoke, fires, and the like due to products, and IDEC shall bear no liability whatsoever regarding special damages,
insulation deterioration or the like. Perform periodic maintenance for IDEC indirect damages, incidental damages, or passive damages that occurred due to an
products and the systems, machines, devices, and the like in which they are IDEC product.
used.
(5) IDEC products are developed and manufactured as general-purpose products 6. Service scope
for general industrial products. They are not intended for use in the following The prices of IDEC products do not include the cost of services, such as dispatching
applications, and in the event that you use an IDEC product for these technicians. Therefore, separate fees are required in the following cases.
applications, unless otherwise agreed upon between you and IDEC, IDEC shall (1) Instructions for installation / adjustment and accompaniment at test operation
provide no guarantees whatsoever regarding IDEC products. (including creating application software and testing operation, etc.)
i. Use in applications that require a high degree of safety, including nuclear (2) Maintenance inspections, adjustments, and repairs
power control equipment, transportation equipment (railroads / airplanes (3) Technical instructions and technical training
/ ships / vehicles / vehicle instruments, etc.), equipment for use in outer (4) Product tests or inspections specified by you
space, elevating equipment, medical instruments, safety devices, or
any other equipment, instruments, or the like that could endanger life or The above content assumes transactions and usage within your region. Please
human health consult with an IDEC sales representative regarding transactions and usage outside
ii. Use in applications that require a high degree of reliability, such as of your region. Also, IDEC provides no guarantees whatsoever regarding IDEC
provision systems for gas / waterworks / electricity, etc., systems that products sold outside your region.
operate continuously for 24 hours, and settlement systems
iii. Use in applications where the product may be handled or used deviating
from the specifications or conditions / environment listed in the Catalogs,
such as equipment used outdoors or applications in environments
subject to chemical pollution or electromagnetic interference
If you would like to use IDEC products in the above applications, be sure
to consult with an IDEC sales representative.

Head Office 6-64, Nishi-Miyahara-2-Chome, Yodogawa-ku, Osaka 532-0004, Japan


www.idec.com
USA IDEC Corporation Singapore IDEC Izumi Asia Pte. Ltd. China IDEC (Shanghai) Corporation Japan IDEC Corporation
EMEA APEM SAS Thailand IDEC Asia (Thailand) Co., Ltd. IDEC Izumi (H.K.) Co., Ltd.
India IDEC Controls India Private Ltd. Taiwan IDEC Taiwan Corporation

Specifications and other descriptions in this brochure are subject to change without notice.

2023 IDEC Corporation, All Rights Reserved.

You might also like