DRYWALL
GB ORDERLINE March 2017
For placing orders, delivery enquiries
and local stockists etc.
0800 373636
MANUAL
01275 379037
orderline@etexbp.co.uk
IRELAND ORDERLINE
For placing orders, delivery enquiries
PLASTERBOARD SYSTEMS FOR
and local stockists etc.
+353 (0) 16203114
PARTITIONS, CEILINGS AND
01275 379037 WALL LININGS
irelandorders@etexbp.com
LITERATURELINE
For Siniat literature.
01275 377582
literatureline@siniat.co.uk
WALL LININGS
PARTITIONS, CEILINGS AND
PLASTERBOARD SYSTEMS FOR
Etex Building Performance Limited
Marsh Lane, Easton-in-Gordano, Bristol, BS20 0NE
+44 (0)1275 377773 www.siniat.co.uk
© 2017 Etex Building Performance Limited
LININGS 178
TM
FIRE PROTECTION 242
FINISHING 276
Siniat is a manufacturer of Promat is a specialist in EOS Façades specialise in
plasterboard and other drylining passive fire protection and the design, manufacture and
products. It makes systems for performance insulation. supply of a wide range of REFER... Product Reference 292
partitions, ceilings, wall linings and steel solutions for the Steel Framing
external sheathing purposes. Systems (SFS) and off-site markets. Profile Guide 332
Screw Selection Guide 334
Sustainability 336
This document is intended as guidance for the correct use All reasonable efforts have been made to ensure its Health and Safety 341
of Siniat GTEC products and systems in typical, best practice accuracy and future changes and improvements may
applications. The detailed technical information is to assist be made without prejudice or notice. Standards 342
you in selecting and specifying the correct systems for your
intended applications, but it does not cover all possible The correct installation and specification of GTEC systems Index 344
configurations of products in all possible constructions. and components is the responsibility of the contractor and
the specifier.
If your project requirements differ, please get in touch with us.
All GTEC systems should be constructed in accordance The latest version of this publication can be
We make reference to products to supplied by other with all relevant building regulations and the guidance in found at: www.siniat.co.uk/drywallmanual
manufacturers; please seek their advice when using these ‘BS 8212:1995 Code of Practice for Drylining and Partitioning
products. In addition, please seek advice from fixing suppliers using Gypsum Plasterboard’, ‘BS 8000-8:1994 Workmanship
and/or qualified professionals when you are fixing our products on building sites – Code of practice for plasterboard partitions
to various structures. and dry linings’ and ‘BS EN 13964:2004+A1:2006 Suspended
ceilings – requirements and test methods’. GTEC is registered
This document is non-exhaustive and provides general advice trademark of Siniat Limited.
in line with good practice; further information should be
sought when required. © 2017 Etex Building Performance Limited
PARTITIONS
CONSIDER... SYSTEMS FOR HEALTHCARE 5
SYSTEMS FOR EDUCATION 7
SYSTEMS FOR RESIDENTIAL 9
SPECIFY... PARTITIONS 20
LININGS 178
LININGS
FIRE PROTECTION 242
FINISHING 276
FIRE PROTECTION
Profile Guide 332
Screw Selection Guide 334
Sustainability 336
Health and Safety 341
Standards 342
Index 344
FINISHING
PROUDLY MANUFACTURING
IN BRISTOL AND YORKSHIRE
OUR
SERVICE 2
LININGS
Our products and components
The majority of our products are manufactured are rigorously tested together STEM
SY
here in the UK and are 99% recyclable. to ensure compatibility and
They are also: system performance, enabling
us to guarantee the technical
BRE Green Guide A / A+ rated and help performance of our systems. AR
Y
W
T
When systems are built entirely RAN
FIRE PROTECTION
collect sustainability code credits
with GTEC components
Certified and managed sustainability to and materials - by qualified professionals and
Responsible Sourcing BES 6001, ISO 9001 in accordance with our latest literature and
and ISO 14001 relevant standards - we can offer our Lifetime
System Warranty.
Our teams help designers and contractors
achieve their sustainability targets for specific In the unlikely event of failure, provided the
projects through efficient design detailing and system is unaltered, as originally designed and
the careful selection of appropriate products built, we will reinstate the system to its originally
and systems. specified performance level. This warranty gives
the confidence that Siniat GTEC systems will
Where needed, we can create bespoke lengths perform as intended throughout the life of the
FINISHING
5
INTRODUCTION
INTRODUCTION
SYSTEMS FOR
HEALTHCARE
GTEC Plasterboard Systems have been used extensively in major
healthcare projects across the UK and Ireland as fast and effective
PARTITIONS
solutions to healthcare construction.
GTEC Boards and GTEC Systems have been developed to meet and
exceed the full range of extraordinary demands placed on hospital
EXTRAORDINARY DEMANDS
ACOUSTICS: The acoustic demands on partitions in Healthcare buildings are extreme; from
ensuring consultation room privacy and operation suite concentration, to
dealing with emergency vehicle sirens and the intensity of A&E departments.
While layout can ease noise risk, GTEC Systems allow for flexible design with
extremely high levels of sound insulation from space to space. The partition
performance ensures that a superior healing environment is achieved. GTEC
Pregybel ceilings also help to control noise levels through acoustic absorption.
LININGS
multiple service entrances and numerous circulation routes, place a high fire
resistance demand on any project.
GTEC Partitions and GTEC Ceilings provide a simple design with high levels
of fire resistance and robust detailing for design flexibility. GTEC Shaftwall
and GTEC Encasement Fire Protection solutions offer specialist passive fire
protection to lifts, shafts and structural steel.
FIRE PROTECTION
IMPACT: Hospitals are dynamic, high traffic, public environments where walls are
subject to constant impact from staff, visitors and hospital equipment.
HYGIENE: Easy to clean surfaces are vital for good healthcare environments which need
frequent washing, and are dependent on excellent hygiene.
GTEC Finishing solutions combined with GTEC Partition and Lining systems
offer smooth, easy to joint and repairable surfaces which are easier to clean.
FINISHING
7
INTRODUCTION
INTRODUCTION
SYSTEMS FOR
EDUCATION
GTEC Plasterboard Systems have been adopted in hundreds of
school, academy, college and university projects across the UK and
PARTITIONS
Ireland to efficiently meet the needs of education construction.
The range of GTEC Board and GTEC Systems suit the full scope
of extraordinary demands placed on education buildings.
FIRE: “Each year around 1 in 20 schools experiences a fire and nearly 60% of school
fires are started deliberately.” BB100
LININGS
Large circulation areas, multi-storey construction and broad types of use from science
labs to sports halls place a high fire resistance need on any Education project.
GTEC Partitions and GTEC Ceilings achieve high levels of fire resistance
with uncomplicated, robust and proven detailing for design flexibility.
GTEC Shaftwall and GTEC Encasement Fire Protection solutions offer
specialist passive fire protection to lifts, shafts and structural steel.
FIRE PROTECTION
IMPACT: Education buildings face some of the most intense usage. With high levels
of student movement, a wide variety of activities taking place and the chance
of misuse, careful specification is needed to reduce maintenance and repairs.
GTEC LaDura Board is exceptionally strong and achieves severe duty ratings
with the minimum of boarding. It offers excellent impact performance for
corridors and high levels of fixing resistance for fixtures and fittings.
9
INTRODUCTION
INTRODUCTION
SYSTEMS FOR
RESIDENTIAL
GTEC Plasterboard Systems have been used across the UK and
Ireland to successfully build or renovate thousands of housing,
PARTITIONS
apartment and hotel projects.
The diverse range of GTEC Board and GTEC Systems features solutions
ideal for the construction of homes and other residential buildings.
GTEC Systems are tested to achieve extremely high levels of sound insulation.
They meet Part E Regulations and the enhanced CSH (Code for Sustainable
Homes) requirements* with the minimum of components.
*+3dB and +5dB over Part E for separating elements (Code for Sustainable Homes Technical Guide – November 2010)
FIRE: With occupants of all ages, most often present at night while they are asleep,
a fire resistant design is essential. Multi-storey buildings and their escape
LININGS
routes present even greater fire resistance needs, as stipulated by Building
Regulations Part B – Fire Safety.
GTEC Partitions and GTEC Ceilings achieve a full range of fire resistance using
minimal components for multi-storey apartments, dense housing developments
and detached houses. Robust and proven detailing enables design flexibility
and economic construction.
FIRE PROTECTION
SUSTAINABILITY: Dwellings are responsible for up to 30% of national carbon emissions through
their construction and use. Huge changes to the Building Regulations have
been implemented to reduce these carbon emissions representing a major shift
in construction methods.
All GTEC Lining systems can provide insulation to enhance the thermal
performance of external walls. These include the GTEC Thermal Boards range;
thermally laminated plasterboards which are recommended by Approved
FINISHING
Approved Document Part E 2003 – Resistance to the Approved Document Part L1 A&B 2013 – Conservation of
Passage of Sound Fuel and Power
INVENTED
BY SINIAT
From over 30 years of experience on building sites we know
there is unmet potential in drywall and have created the
boards to unlock it.
Excellent fire and acoustic performance is always plasterboards which offer exceptional water
expected and we have the range of boards with resistance, exceptional strength and exceptional
higher densities, highly developed additives and finishing speed.
patented technology to achieve the top levels
of fire and sound performance needed in the UK We also know that one board can do more than
and Ireland. one thing. Our boards combine the highest levels
of performance making them suitable for a huge
But we don’t consider that to be enough. Better breadth of applications, reducing the amount
finishing capabilities are available. As a result we of fixing, and potentially meaning only a single
are the first and only manufacturers of gypsum board type is needed on site.
11
INTRODUCTION
INTRODUCTION
Aqua Board
Type GM-F, GM-H1 and GM-I to BS EN 15283
Highly water resistant gypsum board
for wet areas.
PARTITIONS
High sound and fire resistance
LININGS
Megadeco
Type D,F, I and R to BS EN 520
FIRE PROTECTION
Pre-sealed, white faced board for
ease of decoration and finishing.
SYSTEM SOLUTIONS
Each of our three unique boards elevates the final layer of the partition,
ceiling or lining, to previously unknown levels of standard plasterboard
construction. These capabilities drive a different ethos in specifying
drywall systems – the basic demands of acoustics and fire are always
achievable and the focus can now switch to these extra benefits.
Good design means every space has its own needs and tuning boards
to best suit these demands is made possible.
13
INTRODUCTION
INTRODUCTION
MIXING LAYERS
As Siniat’s unique boards offer their key GTEC Fire Board where fire resistance is key
improvements to the final layer of a system it
can make sense to lower the capabilities of the GTEC dB Board where high sound insulation
inner board. Lower performing base layers can is most important
PARTITIONS
be used to open up new opportunities in system
GTEC Standard Board or Plank where a lower
design, to value engineer, or to tune performance
density base layer will suffice
characteristics. These standardised layers, used
as a base, are composed to build a system exactly
right for the situation, e.g.:
LININGS
NOTE: System specific system boards, e.g. GTEC Acoustic Homespan Board and GTEC Contour Board are not included in the above matrix.
FIRE PROTECTION
FINISHING
Homogenous
Homogenous System
System MixedBoard
Mixed Board System
System Homogenous System
Single board type
• Single board type required Superior final layer
• Superior final layer performance • Single board type required
required
• More limited performance performance
• Improved attenuation range • More limited performance
More limited Improved attenuation
performance range
REFERENCE
THE
EXTERNAL
ENVELOPE
Siniat is not just about internal works - gypsum solutions are
revolutionising the external envelope too. Siniat has developed Weather
Defence – an external sheathing board which has transformed building
envelope performance and construction. Weather Defence is made from
gypsum and has a patented hydrophobic core and water resistant liner –
and is a replacement for cement particle boards.
www.siniat.co.uk/weatherdefence
T: 01275 377582
E: literatureline@siniat.co.uk
15
INTRODUCTION
INTRODUCTION
PARTITIONS
FLOORS AND CEILINGS
LININGS
FIRE PROTECTION
SYSTEM
PERFORMANCE
FIRE
Gypsum is a naturally fire resistant material, locking in water which will
be released during a fire. This water controls the temperature allowing
plasterboard systems to survive a fire for substantial lengths of time.
The requirement for fire protection in a project is TYPICAL PARTITION AND FLOOR
driven by the Building Regulations, fire strategy REQUIREMENTS*
and any high risk equipment or activity in a
30 mins Between rooms within a dwelling or
building. The ratings in this manual represent office unit
the minimum passive fire protection that
can be expected in a fire and can be used to 60 mins Separating adjacent units in low rise
buildings
show compliance with the current Building
Regulations in the UK and Northern Ireland. 90 mins Between units in medium rise buildings
17
INTRODUCTION
INTRODUCTION
ACOUSTICS
Control of sound in buildings is essential for comfort. Plasterboard systems
can assist with acoustic requirements in two ways, through sound insulation
and sound absorption. Sound insulation is principally driven by the surface
PARTITIONS
mass of a building element. As a thin, dense material plasterboard can be
used to provide adaptable solutions for minimising sound transmission.
Plasterboards generally reflect sound, however, perforated boards enable
effective sound absorbing systems to be built.
LININGS
sound pressure between the two spaces being
recorded; this testing is carried out to BS EN the best site results – just one air path can
ISO 140 and BS EN ISO 717 standards. The result dramatically diminish the sound insulation
is the Weighted Sound Reduction Index (Rw) of an element.
measured in decibels (dB) with higher values
offering better insulation. Sound absorption is calculated through laboratory
FIRE PROTECTION
testing to European and ISO standards where
Site testing uses a different measurement a component is located in a space with known
method of Standardised Level Difference (DnT,w) reverberation – the resulting reduction in
where values around 7dB lower than laboratory reverberation time gives a coefficient of sound
tests can be expected. It is critical to seal all absorption. This co-efficient varies between 0
air paths, avoid routes for sound to ‘flank’ the and 1 with higher values representing greater
element and build to high standards to achieve absorption per square metre.
FINISHING
REFERENCE
STRUCTURE
A major advantage of plasterboard systems is their low mass to height/span
ratio, this enables tall partitions and wide spans to be created without imposing
high loads on structures supporting the system. As a lightweight system overall
robustness must be considered and by using the correct framework and board
combinations extremely tough partitions, ceilings and linings can be built.
The maximum height of a partition is determined Based on extensive testing and calculations
from its ability to resist a uniformly distributed the height values shown in this manual are the
lateral pressure, taken as 0.2kN/m2 for most maximum that the system can safely satisfy
internal applications, and limiting the resulting when fully built. Care must be taken during
deflection to height/240. Greater lateral pressures construction to ensure that the construction
and other imposed loads are possible and depend sequence does not undermine structural
on the layout adopted. The ‘Strength’ criterion strength and construction loads are not
in the System Performance Tables is determined applied to the systems.
according to the test methods and criteria
given in BS 5234-2. There are four grades in the The ceiling systems in this publication will not
standard, increasing in robustness from Light, support imposed loads in addition to those
Medium, Heavy to Severe Duty. In most projects given in the appropriate sections. Fixings to
the use of the lowest duty grade will result in structural elements must be determined by
walls which are too flexible for the expectations suitably qualified professionals and are not the
of users and are not generally recommended. responsibility of Siniat.
Light Duty Adjacent space only accessible to persons with high incentive Domestic accommodation
to exercise care. Small chances of accident or of misuse.
Medium Duty Adjacent space moderately used primarily by persons with Office accommodation
some incentive to exercise care. Chances of accident
occurring and of misuse.
Heavy Duty Adjacent space frequently used by the public and others with Public circulation areas
little incentive to exercise care. Chances of accident occurring Industrial areas
and of misuse.
Severe Duty Adjacent space intensively used by the public and others Major circulation areas
with little incentive to exercise care. Prone to vandalism and Heavy industrial areas
abnormally rough use.
Table extract from BS 5234-2: 1992
SYSTEM PERFORMANCE
19
INTRODUCTION
INTRODUCTION
THERMAL
Plasterboard is not a low conductivity material but can be combined easily with
different types of thermal insulation to create systems or products (such as GTEC
Thermal Boards) which offer excellent thermal insulation properties. Plasterboard
systems can contribute to construction with the most thermally efficient U-values
satisfying new build or renovation building regulation requirements.
PARTITIONS
Plasterboard is dimensionally stable and can be this manual so it is often possible to achieve
ideal as the air-tightness envelope in a building, improved U-values by changing the quality and
with projects typically achieving 3m3/hr/m2 quantity of insulation, contact Technical Services
@ 50Pa, exceeding the building regulation for further information.
requirement. The stability of plasterboard
systems also allows construction independent U-values are calculated, following the
of the substrate to prevent thermal bridging. conventions of BR 443, using specialist
LININGS
App. Doc. L1B/L2B App. Doc. L1B/L2B App. Doc. L1B/L2B App. Doc. L1A/L1B Low Carbon*
Construction
‘New’ ‘Improved’ ‘Threshold’ ‘Limiting’
FIRE PROTECTION
Pitched roof (insulation at ceiling level) 0.16 0.16 0.35 0.20 0.13
Pitched roof (insulation at rafter level) 0.18 0.18 0.35 0.20 0.13
PARTITIONS
The GTEC range of metal stud profiles provides system solutions
for most building projects. Combining the right GTEC plasterboard,
LININGS
GTEC Fire Board Partition Systems 38
GTEC Standard Board Partition Systems 41
GTEC Acoustic Homespan Partition Systems 43
GTEC E Board Partition Systems 44
FIRE PROTECTION
GTEC Structural Frame Partition Systems 45
Masonry Robust Detail Systems 46
GTEC Timber Partition Systems 47
i
22 GTEC PARTITIONS – PERFORMANCE TABLES
23
INTRODUCTION
INTRODUCTION
System Max. Overall Fire Perf. Strength Acoustic
Weight Height Thickness BS476-22 Duty Perf.
BS EN Rating to Rw dB
1364-1 BS 5234-2 (Ctr if
(kg/m2) (m) (mm) (mins) applicable)
System Ref. Component
PARTITIONS
Facing Inner Layer(s): 52 5 120 120 Severe 56
1x 12.5mm LaDura Board 90
Facing Outer Layer(s):
1x 12.5mm LaDura Board
Studs: Single GTEC CS70Rx C Studs
at 600mm centres
Insulation: 25mm 16kg/m3 glass
LININGS
Facing Outer Layer(s):
1x 15mm LaDura Board
Studs: Single GTEC CS70Rx C Studs
at 600mm centres
Insulation: 25mm 16kg/m3 glass
mineral wool
Accessories: –
FIRE PROTECTION
LDP 128: C Stud Partition – see p50
Facing Outer Layer(s): 33 5.0 120 60 Severe 50
1x 15mm LaDura Board 60
Studs: Single GTEC CS90Rx C Studs
at 600mm centres
Insulation: 25mm 16kg/m3 glass
mineral wool
Accessories: –
25
INTRODUCTION
INTRODUCTION
System Max. Overall Fire Perf. Strength Acoustic
Weight Height Thickness BS476-22 Duty Perf.
BS EN Rating to Rw dB
1364-1 BS 5234-2 (Ctr if
(kg/m2) (m) (mm) (mins) applicable)
System Ref. Component
PARTITIONS
Facing Outer Layer(s): 33 5.0 170 60 Severe 56
1x 15mm LaDura Board 60
Studs: Twin GTEC CS50Rx C Studs at
600mm centres
Insulation: 50mm 16kg/m3 glass
mineral wool
Accessories: GTEC V-Brace at
LININGS
FIRE PROTECTION
FINISHING
REFERENCE
27
INTRODUCTION
INTRODUCTION
System Max. Overall Fire Perf. Strength Acoustic
Weight Height Thickness BS476-22 Duty Perf.
BS EN Rating to Rw dB
1364-1 BS 5234-2 (Ctr if
(kg/m2) (m) (mm) (mins) applicable)
System Ref. Component
PARTITIONS
Facing Outer Layer(s): 28 3.6 100 60 Severe 52
1x 15mm Aqua Board, 60
1x 15mm Megadeco Board
Studs: Single GTEC AS70Rx Acoustic
C Studs at 600mm centres
Insulation: GTEC AS70Rx Acoustic C
Studs at 600mm centres
LININGS
FIRE PROTECTION
FINISHING
REFERENCE
29
INTRODUCTION
INTRODUCTION
System Max. Overall Fire Perf. Strength Acoustic
Weight Height Thickness BS476-22 Duty Perf.
BS EN Rating to Rw dB
1364-1 BS 5234-2 (Ctr if
(kg/m2) (m) (mm) (mins) applicable)
System Ref. Component
PARTITIONS
Facing Inner Layer(s): 40 4.6 120 60 Severe 56
1x 9.5mm GTEC Standard Board 60
Facing Outer Layer(s):
1x 15mm Megadeco Board
Studs: Single GTEC CS70Rx C Studs
at 600mm centres
Insulation: 25mm 16kg/m3 glass
LININGS
1x 12.5mm Megadeco Board
Studs: Single GTEC CS70Rx C Studs
at 600mm centres
Insulation: 25mm 16kg/m3 glass
mineral wool
Accessories: –
FIRE PROTECTION
Facing Outer Layer(s): 27 4.6 120 60 Severe 42
1x 15mm Megadeco Board 60
Studs: Single GTEC CS90Rx C Studs
at 600mm centres
Insulation: –
Accessories: –
Accessories: –
mineral wool
Accessories: –
31
INTRODUCTION
INTRODUCTION
System Max. Overall Fire Perf. Strength Acoustic
Weight Height Thickness BS476-22 Duty Perf.
BS EN Rating to Rw dB
1364-1 BS 5234-2 (Ctr if
(kg/m2) (m) (mm) (mins) applicable)
System Ref. Component
PARTITIONS
Facing Outer Layer(s): 29 8.8 176 60 Severe 42
1x 15mm Megadeco Board 60
Studs: Single GTEC CS146Y C Studs
at 600mm centres
Insulation: –
Accessories:–
LININGS
Accessories: –
FIRE PROTECTION
600mm centres
Insulation: 25mm 16kg/m3 glass
mineral wool
Accessories: GTEC V-Brace at
1500mm centres
Accessories: –
REFERENCE
33
INTRODUCTION
INTRODUCTION
GTEC dB BOARD PARTITION SYSTEMS
PARTITIONS
Facing Outer Layer(s): 27 3.0 80 30 Heavy 40
1x 15mm GTEC dB Board 30
Studs: Single GTEC CS50Rx C Studs
at 600mm centres
Insulation: –
Accessories: –
LININGS
RSP 028: C Stud Partition – see p50
Facing Outer Layer(s): 23 3.5 95 30 Medium 45
1x 12.5mm GTEC dB Board 30
Studs: Single GTEC CS70Rx C Studs
at 600mm centres
Insulation: 25mm 16kg/m3 glass
mineral wool
FIRE PROTECTION
Accessories: –
at 600mm centres
Insulation: 25mm 16kg/m3 glass
mineral wool
Accessories: –
REFERENCE
35
INTRODUCTION
INTRODUCTION
System Max. Overall Fire Perf. Strength Acoustic
Weight Height Thickness BS476-22 Duty Perf.
BS EN Rating to Rw dB
1364-1 BS 5234-2 (Ctr if
(kg/m2) (m) (mm) (mins) applicable)
System Ref. Component
PARTITIONS
Facing Inner Layer(s): 54 8.9 206 90 Severe 57
1x 15mm GTEC dB Board 90
Facing Outer Layer(s):
1x 15mm GTEC dB Board
Studs: Single GTEC CS146Rx C Studs
at 600mm centres
Insulation: 25mm 16kg/m3 glass
LININGS
1x 12.5mm GTEC dB Board 60 -9 Ctr
Facing Outer Layer(s):
1x 12.5mm GTEC dB Board
Studs: Twin GTEC CS90W C Studs
at 600mm centres
Insulation: 100mm 10kg/m3 glass
mineral wool
Accessories: GTEC V-Brace at
FIRE PROTECTION
3000mm centres plus extension
37
INTRODUCTION
INTRODUCTION
System Max. Overall Fire Perf. Strength Acoustic
Weight Height Thickness BS476-22 Duty Perf.
BS EN Rating to Rw dB
1364-1 BS 5234-2 (Ctr if
(kg/m2) (m) (mm) (mins) applicable)
System Ref. Component
PARTITIONS
Facing Inner Layer(s): 55 7.85 206 90 Severe 61
1x 15mm GTEC dB Board 90 -6 Ctr
Facing Outer Layer(s):
1x 15mm GTEC dB Board
Studs: Single GTEC AS146Rx C Studs
at 600mm centres
Insulation: 100mm 10kg/m3 glass
LININGS
FIRE PROTECTION
FINISHING
REFERENCE
39
INTRODUCTION
INTRODUCTION
System Max. Overall Fire Perf. Strength Acoustic
Weight Height Thickness BS476-22 Duty Perf.
BS EN Rating to Rw dB
1364-1 BS 5234-2 (Ctr if
(kg/m2) (m) (mm) (mins) applicable)
System Ref. Component
PARTITIONS
Facing Inner Layer(s): 51 4.5 130 120 Severe 56
1x 15mm GTEC Fire Board 120
Facing Outer Layer(s):
1x 15mm GTEC Fire Board
Studs: Single GTEC CS70Rx C Studs
at 600mm centres
Insulation: 25mm 16kg/m3 glass
LININGS
at 600mm centres
Insulation: None
Accessories: –
FIRE PROTECTION
Facing Outer Layer(s):
1x 12.5mm GTEC Fire Board
Studs: Single GTEC CS90Rx C Studs
at 600mm centres
Insulation: 25mm 16kg/m3 glass
mineral wool
Accessories: –
41
INTRODUCTION
INTRODUCTION
GTEC STANDARD BOARD PARTITION SYSTEMS
PARTITIONS
Facing Outer Layer(s): 17 2.6 75 30 Medium 34
1x 12.5mm GTEC Standard Board –
Studs: Single GTEC CS50Rx C Studs
at 600mm centres
Insulation: –
Accessories: –
LININGS
RCP 045: C Stud Partition – see p50
Facing Inner Layer(s): 34 4.05 120 60 Severe 45
1x 12.5mm GTEC Standard Board 30
Facing Outer Layer(s):
1x 12.5mm GTEC Standard Board
Studs: Single GTEC CS70Rx C Studs
FIRE PROTECTION
at 600mm centres
Insulation: None
Accessories: –
43
INTRODUCTION
INTRODUCTION
GTEC ACOUSTIC HOMESPAN PARTITION SYSTEMS
PARTITIONS
Facing Outer Layer(s): 28 2.7 74 30 Heavy 40
1x 15mm GTEC Acoustic 30
Homespan Board
Studs: GTEC AHS44Rx Acoustic
Homespan Studs at 450mm centres
Insulation: –
Accessories: –
LININGS
Insulation: –
Accessories: –
FIRE PROTECTION
Homespan Board
Studs: GTEC AHS50Rx Acoustic
Homespan Studs at 450mm centres
Insulation: 25mm 16kg/m3 glass
mineral wool
Accessories: –
FINISHING
REFERENCE
45
INTRODUCTION
INTRODUCTION
GTEC STRUCTURAL FRAME PARTITION SYSTEMS
E-WS-1
PARTITIONS
Facing Inner Layer(s): – 4.5 310 60 Severe Robust
1x 15mm GTEC dB Board 60 Detail
Facing Outer Layer(s): Solution
1x 15mm GTEC dB Board
Studs: Twin Structural C-Studs
at 600mm centres
Insulation: 1x 50mm 33-60kg/m3
E-WS-1 alt.
Facing Inner Layer(s): – 4.5 315 60 Severe Robust
1x 19mm GTEC Plank Board 60 Detail
Facing Outer Layer(s): Solution
1x 12.5mm GTEC Fire Board
Studs: Twin Structural C-Studs
at 600mm centres
Insulation: 1x 50mm 33-60kg/m3
mineral wool
Accessories: –
RLB 003
Facing Inner Layer(s): – 4.0 310 90 Severe 66
1x 15mm GTEC dB Board 60 -9 Ctr
LININGS
Facing Outer Layer(s):
1x 15mm GTEC dB Board
Studs: Twin 100mm Structural
C-Studs at 600mm centres
Insulation: 2x 75mm 24kg/m3 glass
mineral wool
Accessories: –
FIRE PROTECTION
RLB 014
Facing Inner Layer(s): – 4.5 245 60 Severe 61
1x 15mm GTEC dB Board 60 -7 Ctr
Facing Outer Layer(s):
1 x 15mm GTEC Fire Board
Studs: Single 150mm Structural
C-Studs at 600mm centres
Insulation: 50mm 24kg/m3 glass
mineral wool
Accessories: Single GTEC Resilient
Bar at 600mm vertical centres
both sides
FINISHING
REFERENCE
E-WM-3
Facing Outer Layer(s): – 5.2 315 240 – Robust
1x 12.5mm GTEC Standard Board 240 Detail
both sides Solution
Lining: Sand Cement render
Universal Bonding Compound
to form 10mm cavity
Cavity: 75mm; Insulation: –
Internal Wall Leaf: 100mm Blocks
Density 1850-2300kg/m3
External Wall Leaf: 100mm Blocks
Density 1850-2300kg/m3
E-WM-4
Facing Outer Layer(s): – 5.2 315 240 – Robust
1x 12.5mm GTEC Standard Board 240 Detail
both sides Solution
Lining: GTEC E Coat Render
Universal Bonding Compound
to form 10mm cavity
Cavity: 75mm; Insulation: –
Internal Wall Leaf: 100mm Blocks
Density 1350-1600kg/m3
External Wall Leaf: 100mm Blocks
Density 1350-1600kg/m3
E-WM-5
Facing Outer Layer(s): – 5.2 315 240 – Robust
1x 12.5mm GTEC Standard Board 240 Detail
both sides Solution
Lining: Sand Cement render
Universal Bonding Compound
to form 10mm cavity
Cavity: 75mm; Insulation: –
Internal Wall Leaf: 100mm Star
Performer Blocks
External Wall Leaf: 100mm Star
Performer Blocks
E-WM-11
Facing Outer Layer(s): GTEC 12.5mm – 5.2 315 240 – Robust
Standard Board both sides 240 Detail
Lining: GTEC E Coat Render Solution
Universal Bonding Compound
to form 10mm cavity
Cavity: 100mm; Insulation: –
Internal Wall Leaf: 100mm Blocks
Density 1350-1600kg/m3
External Wall Leaf: 100mm Blocks
Density 1350-1600kg/m3
47
INTRODUCTION
INTRODUCTION
GTEC TIMBER PARTITION SYSTEMS
PARTITIONS
RTP 152: Timber Partition – see p110
Facing Inner Layer(s): 55 3.6 166 60 60 Severe 57
1x 15mm GTEC dB Board 60 60
Facing Outer Layer(s):
1x 15mm GTEC dB Board
LININGS
Facing Outer Layer(s): 18 3.0 88 30 – Medium 35
1x 12.5mm GTEC Standard – –
Board
Studs: 38x63mm Timber
Studs at 600mm centres
Insulation: –
Accessories: –
FIRE PROTECTION
RTP 005: Timber Partition – see p110
Facing Outer Layer(s): 21 3.9 114 30 30 Medium 35
1x 12.5mm GTEC Standard 30 –
Board
Studs: 38x89mm Timber
Studs at 600mm centres
Insulation: –
Accessories: –
49
INTRODUCTION
INTRODUCTION
System Max. Overall Fire Perf. Fire Perf. Strength Acoustic
Weight Height Thickness BS476-22 BS476-21 Duty Perf.
Non-load Load Rating to Rw dB
bearing bearing BS 5234 (Ctr if
(NLB) (LB) applicable)
BS EN BS EN
1364-1 1365-1
System Ref. Component (kg/m2) (m) (mm) (mins) (mins)
PARTITIONS
RTP 043: Timber Partition – see p110
Facing Inner Layer(s): 39 3.4 138 60 60 Severe 45
1x 12.5mm GTEC Standard 60 60
Board
Facing Outer Layer(s):
LININGS
Studs: 38x88mm Timber
Studs at 600mm centres
Insulation: 25mm 16kg/m3
glass mineral wool
Accessories: –
FIRE PROTECTION
Facing Inner Layer(s): 35 3.4 138 30 30 Severe 42
1x 12.5mm GTEC Standard 30 –
Board
Facing Outer Layer(s):
1x 12.5mm GTEC Standard
Board
Studs: 38x88mm Timber
Studs at 600mm centres
Insulation: –
Accessories: –
Performance values are for imperforate, jointed systems using Siniat GTEC components (metal studs and tracks, boards, metal accessories, screws and
finishing systems) and specified insulation quilt material (type, thickness and density) and installed to Siniat specification and installation guides.
Any alterations may impair the quoted performance. Contact Technical Services for further system configurations and their resulting performances.
All maximum partition heights are calculated with a uniform lateral pressure of 0.2kN/m2, the quoted height reflects the most onerous deflection limit
of two conditions: 10mm deflection at 1.5m height (equivalent to Severe duty); or maximum deflection of height/240 at mid-height.
Maximum height can be increased by 0.3m for single layer boarding and by 0.6m for double layer boarding when studs centres are reduced to 400mm.
It may be possible to increase heights from those quoted in the system tables where reduced deflection limits or pressure criteria are acceptable.
The maximum partition height may vary from the quoted values if the fire resistance of the system is specified according to BS EN 1364-1.
REFERENCE
Insulation shown may be replaced with thicker and/or heavier quilt material without impairing the quoted performances.
See pages 16-19 for further explanation of the performance values quoted in system tables.
GTEC C STUD
PARTITION SYSTEMS
GTEC Metal Stud Partitioning is an economical, friction-fit system for
assembling internal partitions. The unique design of the components
ensures high strength, easy installation and a higher performing
alternative to traditional timber frame partitions.
WHERE TO USE:
GTEC C Stud Partitions create internal dividing walls within both
domestic and commercial projects.
FEATURES BENEFITS
Natural resistance to bowing, bending and Metal maintains shape, removing the chance of
insect infestation ‘screw popping’
High fire resistance levels Fire performance levels are easily achieved
using metal
High acoustic performance levels Acoustic performance levels are easily achieved
using metal
51
GTEC C STUD PARTITION
INTRODUCTION
INTRODUCTION
PARTITIONS
FLOORS AND CEILINGS
GTEC Intumescent Acoustic Sealant
GTEC Board
to suit required performance
LININGS
timber stud for
jamb reinforcement
FIRE PROTECTION
GTEC Insulation Hold
at 1200mm centres
BOARDS
All GTEC Boards See performance tables, p22-44
Provides wall surface suitable for finishing
FRAME
GTEC C Stud CS50/RX, CS60/RX, CS70/RX, CS90/RX,
Metal profile for vertical frame elements CS146/RX, CS70/B, CS90/B, CS146/B,
CS90/W, CS70/Y, CS90/Y, CS146/Y
INSULATION
Mineral wool insulation See performance table
Increases fire and acoustic insulation performance supplied by others
GTEC Insulation Hold INSR
Secures insulation to prevent slump
FIX
GTEC Drywall Screws (as appropriate) See fixing selector, p334-335
For connecting plasterboard and metal components
FINISHING
GTEC Corner and Edge beads n/a
Corner and edge reinforcement
53
INTRODUCTION
INTRODUCTION
SYSTEM GUIDANCE
FRAME
PT-CS-101S-Head – no deflection PT-CS-102S-Base
GTEC U Track
fixed at max. 600mm centres GTEC Board
to suit required performance 5mm
shorter than floor to ceiling height
GTEC Intumescent Acoustic
Sealant
PARTITIONS
screw fix plasterboard to track
GTEC C Stud
cut 5mm shorter
than floor to ceiling height
SECTION SECTION
GTEC Board
to suit required
performance GTEC Board
GTEC C Stud to suit required performance
LININGS
GTEC Intumescent
Acoustic Sealant GTEC C Stud
boxed or increase stud gauge
FLOATING SCREED
FIRE PROTECTION
SECTION PLAN
PT-CS-105M-Stud splice
600mm overlap
for height ≤ 4m
FINISHING
ISOMETRIC
FRAME continued
Select compatible sizes (e.g. 50mm stud Protect base track from moisture with damp
and 52mm track) of GTEC C Stud and proof membrane when situated on newly laid
GTEC U Track framing elements concrete floors.
to meet system performance.
All GTEC C Studs to be 5mm shorter than
GTEC U Track Deep or Extra Deep Flange to floor to ceiling height except in case of head
be used for heights greater than 4.2m and deflection requirement (see p61).
where deflection allowance is required.
Intermediate GTEC C Studs, facing in same
Studs abutting structure (starter studs) to direction, to be friction fitted into tracks to
be fixed with web flat to structure using allow for adjustment during boarding.
appropriate fixings by others at maximum
600mm centres and fixed to head and track GTEC C Studs to be at centres required to
with appropriate GTEC Drywall Screws meet system performance with a maximum
(see screw selector, p334-335). of 600mm centres.
GTEC U Track to be fixed flat to structure Where wall height exceeds available
using appropriate fixings by others at GTEC Stud length splice two lengths
maximum 600mm centres. together ensuring overlap of 600mm
for heights less than 4m and 1000mm
Timber sole plate may be required on uneven for heights more than 4m.
floors or where partition is constructed prior
to screeding.
INSULATION
PT-CS-151M-Insulation Hold
Insulation, if required, to be of type and
thickness to achieve performance and
GTEC Insulation Hold
installed in a continuous layer between
to support each insulation batt
frames or studs.
ISOMETRIC
GTEC C STUD PARTITION
55
INTRODUCTION
INTRODUCTION
BOARDING
PT-CS-201M-Board fixing – single layer PT-CS-202M-Board fixing – double layer
PARTITIONS
joints on Joints on opposite faces
alternating studs offset and staggered
between layers
PT-CS-203M-Horizontal joint reinforcement, single layer PT-CS-204M-Horizontal joint reinforcement, double layer
screw fix
screw fix to fixing strap at
LININGS
to fixing strap at max. 300mm centres
max. 300mm centres
FIRE PROTECTION
ISOMETRIC ISOMETRIC
GTEC Twin Frame partition system is suitable Boards to be mechanically fixed to studs
for single, double and multiple layer boarding. at 300mm centres using appropriate
GTEC Drywall Screws (see screw selector,
Select base layer(s) and finishing layer(s) p334-335).
GTEC Boards by consulting System
Performance Tables (p22-24) and Product Base layers of boarding may be temporarily
Specification (p294-307) to achieve required fixed at 600mm centres providing final layer
performance. See High Performance is fixed through to stud at 300mm centres.
FINISHING
Boards to be 5mm less than floor to Stagger all board joints between layers.
ceiling height except in case of deflection
Stagger all board joints on opposing sides
requirement, see p61.
of partition.
REFERENCE
BOARDING continued
Over-height single layer boarding: Over-height multiple layer boarding:
Where partition height exceeds board height Where partition height exceeds board height
GTEC Flat Strap FS90/W or GTEC MFIX to be for double or multiple layer boarding GTEC
fixed behind all horizontal joints to provide Flat Strap FS50/RX to be fixed behind all
substrate for board fixing. horizontal joints in outer layer of board.
10mm between
GTEC Movement
boards and 10mm between Control Joint
screw fix tracks boards and tracks
GTEC Movement
plasterboard Control Joint GTEC Fire Board
to stud 2x 15mm cut to
10mm
exact width of stud
GTEC Board
to suit required
performance
screw fix
GTEC Board GTEC Fire Board 20mm plasterboard to stud
to suit required 2 x 15 mm cut to exact
performance 10mm 10mm width of stud 70mm
PLAN PLAN
Form movement control joints at maximum Fix GTEC Movement Control Joint, butted
10m intervals in the partition run. end-to-end, to board with sheradised or
galvanised staples.
Form movement control joints where the
partition crosses a structural movement joint.
GTEC C STUD PARTITION
57
INTRODUCTION
INTRODUCTION
OPENINGS
PT-CS-401P-Door frames – 30kg to 100kg door loads
Section A-A
GTEC Intumescent Acoustic Sealant
PARTITIONS
Siniat C Stud
Siniat U Track
Siniat C Stud
Timber as required by
Up to 100 kg Door door manufacturer
Siniat C Stud
LININGS
Insert timber both sides from base
to 300mm above door head height
FIRE PROTECTION
Extend door head trim to door jamb
by snipping at 45° and bending 90°
Bend to avoid
sharp edges
Stud at 150mm
Siniat base track snipped and bent
to extend 300mm up studs
Note: Insulation and Boards not shown for clarity
Isometric
ISOMETRIC
OPENINGS continued
Form openings following guidance in Reinforce jamb studs with timber and
Construction Detail Drawings to suit boxed studs as described in Construction
door weights. Detail Drawings.
GTEC C Stud
GTEC C Stud
GTEC Intumescent
Acoustic Sealant
GTEC Board
to suit required
GTEC Board performance
to suit required
performance
PLAN
PLAN
PLAN
PLAN
PLAN
PLAN PLAN
GTEC C STUD PARTITION
59
INTRODUCTION
INTRODUCTION
PT-CS-505P-Acoustic rated T-junctions, single layer PT-CS-506P-Acoustic rated T-junctions, double layer
PARTITIONS
GTEC C Stud GTEC C Stud
screw fix screw fix
plasterboard plasterboard
to stud to stud
PLAN PLAN
screw fix
plasterboard to stud
GTEC C Stud
GTEC External
Corner Tape
LININGS
GTEC C Stud
GTEC Board
to suit required
performance Min. 10mm gap
stud to stud
connection on
GTEC Board alternating sides
FIRE PROTECTION
to suit required
performance
PLAN PLAN
PT-CS-509P-Junction with Masonry – Plastered PT-CS-510P-Junction with Masonry – Dryliner & Direct Bond
GTEC Intumescent
Acoustic Sealant
GTEC Direct Bond
lining system
FINISHING
PLAN PLAN
GTEC Intumescent
Acoustic Sealant
GTEC Direct Bond
lining system
PLAN PLAN
PT-CS-513P-T-Junction of Single into Twin Frame PT-CS-514P-T-Junction of Twin into Single Frame
GTEC Intumescent
Acoustic Sealant
GTEC C Stud or
Acoustic Stud System
PLAN PLAN
Abutting partitions to coincide with studs, See Construction Details Drawings for further
install additional intermediate ‘pick-up’ stud guidance on arrangement and fixing.
if required.
61
INTRODUCTION
INTRODUCTION
HEAD DEFLECTION
PT-CS-601S-Deflection head, general arrangement
PARTITIONS
DETAIL DETAIL
packers cut precisely use head deflection
to track width table to select packers
=
Cloaking angle deflection amount
=
Minimum overlap
deflection amount
of boards and packers
and fixing
LININGS
FIRE PROTECTION
Note: Refer to the deflection table
SECTION
Deflection Packer for all fire ratings: Track for all fire 30 & 60 mins 90 & 120 mins
required: ratings:
0-5mm 12.5mm GTEC Fire Board GTEC U Track (UT) GTEC Intumescent Mineral wool &
Acoustic Sealant cloaking angle
6-10mm 15mm GTEC Fire Board GTEC U Track (UT) GTEC Intumescent Mineral wool &
Acoustic Sealant cloaking angle
11-20mm 2x 12.5mm GTEC Fire Board or GTEC Deep Flange U GTEC Intumescent Mineral wool &
FINISHING
25mm GTEC Fire Core Board Track (UDT) Acoustic Sealant cloaking angle
21-25mm 2x 15mm GTEC Fire Board GTEC Deep Flange U GTEC Intumescent Mineral wool &
Track (UDT) Acoustic Sealant cloaking angle
26-32mm 3x 12.5mm GTEC Fire Board GTEC Deep Flange U GTEC Intumescent Mineral wool &
Track (UDT) Acoustic Sealant cloaking angle
33-40mm 3x 15mm GTEC Fire Board GTEC Extra Deep GTEC Intumescent Mineral wool &
REFERENCE
41-45mm 2x 25mm GTEC Fire Core Board or GTEC Extra Deep GTEC Intumescent Mineral wool &
4x 12.5mm GTEC Fire Board Flange U Track (UXT) Acoustic Sealant cloaking angle
profiled insulation
by others to fill
profile cavity GTEC Intumescent
Acoustic Sealant
GTEC FS90W
at 600mm centres
PROFILED SOFFIT
deflection
deflection
15mm GTEC Fire Board amount
amount
to close cavity between
profile and partition
15mm GTEC Fire
Min. 150mm
use head deflection Board cut to shape
overlap
table to select packer of metal deck profile
SECTION SECTION
profiled insulation
by others to fill
profile cavity
PROFILED SOFFIT
deflection
amount
SECTION
GTEC Board
to suit required
performance
composite box
stud to pick up top fix
(size to suit purlin)
C Stud
SECTION
GTEC C STUD PARTITION
63
INTRODUCTION
INTRODUCTION
PT-CS-608S-Def. Head – perpendicular to purlins PT-CS-609S-Def. Head – under beam
GTEC Intumescent
Acoustic Sealant GTEC U Track
PURLIN ZONE
PARTITIONS
GTEC Metal
deflection amount Angle 90°
SECTION SECTION
studs to be free
Deflection amount moving in both
LININGS
directions
GTEC UXT Track
3x deflection amount
GTEC C Stud
cut short by 80mm + deflection amount
FIRE PROTECTION
GTEC C Stud / U Track
370mm + deflection amount
ISOMETRIC
FINISHING
REFERENCE
GTEC Intumescent
Acoustic Sealant
GTEC C Stud
fixed at 600mm centres between
and screw fixed to purlins
GTEC C Stud
fixed at 600mm centres
GTEC U Track
Telescopic head
GTEC U Track
SECTION
See Construction Detail Drawings and Tables GTEC Studs to be cut short of track by
for full details. Contact Siniat Technical deflection amount.
Services for further information.
GTEC Studs and Tracks to overlap by
Continuity of head packer to be maintained. minimum 20mm.
65
INTRODUCTION
INTRODUCTION
PENETRATIONS
PT-CS-701P-Small diameter pipe penetration PT-CS-702E-Cable tray penetration
GTEC Intumescent
Acoustic Sealant insulation to seal GTEC Fire Board
around penetrating
pipe or conduit
PARTITIONS
GTEC Intumescent
Acoustic Sealant
GTEC U Track
cut and bent
PLAN ELEVATION
LININGS
folded and pushed
into socket box
GTEC U Track
150mm up turn 2x 15mm
GTEC Fire Board
GTEC C Stud
Infill section of
FIRE PROTECTION
GTEC U Track fixed
to lower track
ELEVATION ISOMETRIC
ISOMETRIC
FINISHING
REFERENCE
PENETRATIONS continued
PT-CS-705P-Multiple pipe penetrations – Single frame
150mm
100mm min.
overlap
void filled with dense rock mineral wool
ELEVATION PLAN
GTEC U Track
cut and folded to reinforce
jamb stud
Fire damper
GTEC Intumescent
Acoustic Sealant
Rock mineral wool packed
around damper
max. 600mm
SECTION ELEVATION
M&E runs and other services to be Protect all electrical cables in cavity
pre-planned to minimise or eliminate with conduit.
penetrations through rated partitions.
67
INTRODUCTION
INTRODUCTION
FIXTURES
PT-CS-801M-Flat strap for light-weight fixings PT-CS-802M-Plywood pattress for heavy-weight fixings
GTEC C Stud
PARTITIONS
at max. 300mm centres
ISOMETRIC
ISOMETRIC ISOMETRIC
LININGS
Vertical timber framing as
required fixed into track
FIRE PROTECTION
GTEC U Track
SECTION ISOMETRIC
PT-CS-804M-LaDura adhesive pattress for heavy-weight fixings PT-CS-805M-LaDura channel pattress for heavy-weight fixings
FIXTURES continued
PT-CS-806S-LaDura pattress types for fixings both sides
Select fixture details for recommended
fixture provision in combination with
GTEC Shallow Wall Channel
fixing capability.
69
INTRODUCTION
INTRODUCTION
PT-CS-807M-Spit fixings
PARTITIONS
Spit Spring Toggle Spit Satelis
LININGS
FIRE PROTECTION
Spit Driva® Spit Driva® LD
FINISHING
All board joints to be taped, jointed GTEC Finish materials appropriate to board
or finished according to guidance in type to be used.
Finishing section (p276-291) to achieve
system performances.
SYSTEM CONTINUITY
Bead of GTEC Intumescent Acoustic Sealant GTEC Intumescent Acoustic Sealant to seal
to be applied to perimeter of all runs and in all other acoustic or air paths to prevent fire/
all other locations specified in Construction smoke spread and acoustic transmission.
Detail Drawings.
Full, imperforate system continuity to be
maintained to achieve rated performances.
CURVED PARTITIONS
PT-CS-901M-Single frame curved partition
GTEC Board
to suit required performance
GTEC C Stud
GTEC U Track
minimum 300mm at
each end of curve
15
0m
m
Two C studs separated
by 150mm at start
of straight section
ISOMETRIC
GTEC C STUD PARTITION
71
INTRODUCTION
INTRODUCTION
CURVED PARTITIONS continued
PT-CS-902M-Flex track component
Boards to be installed horizontally.
PARTITIONS
System performance may vary.
GTEC C Stud
GTEC Flex Track Deep Flange
LININGS
GTEC Contour Board or
other GTEC Board as required
FIRE PROTECTION
PLAN
3.0 – 4.0 300 Dry 450 Wet 400 Wet 200 Wet
4.0 – 8.0 300 Dry 450 Wet 500 Wet 400 Wet
8.0 – 12.0 300 Dry 600 Dry 600 Dry 600 Wet
REFERENCE
Compatibility with the GTEC C Stud system and all GTEC Boards
allows a range of partition performances within identical footprints.
For individual system performances, refer to the System Performance
Tables on pages 22 to 44.
WHERE TO USE:
GTEC Acoustic Stud is an internal partition system for commercial and
domestic applications requiring high acoustic performance levels.
Benefits from all key features as detailed for GTEC C Stud, plus:
FEATURES BENEFITS
73
INTRODUCTION
INTRODUCTION
PARTITIONS
FLOORS AND CEILINGS
Insulation to suit required performance
LININGS
GTEC Board
to suit required performance
FIRE PROTECTION
GTEC Intumescent
Acoustic Sealant
FINISHING
REFERENCE
BOARDS
All GTEC Boards See performance table, p22-44
Provides wall surface suitable for finishing
FRAME
GTEC Acoustic Stud AS70/RX, AS90/RX, AS146/RX
Metal profile for vertical frame elements with improved
acoustic performance
GTEC C Stud CS50/RX, CS60/RX, CS70/RX, CS90/RX,
Metal profile for vertical frame elements at corners, CS146/RX, CS70/B, CS90/B, CS146/B,
door openings, abutments CS90/W, CS70/Y, CS90/Y, CS146/Y
FINISHING
GTEC Corner and Edge beads n/a
Corner and edge reinforcement
75
INTRODUCTION
INTRODUCTION
SYSTEM GUIDANCE
See guidance in GTEC C Stud section and additional considerations given below:
FRAME
PT-AS-101M-Stud splice
PARTITIONS
600mm overlap
for height ≤ 4m
ISOMETRIC
Select compatible size (e.g. 70mm stud Intermediate studs to be GTEC Acoustic
and 72mm track) GTEC Acoustic Stud, Studs, facing in same direction, to be
GTEC C Stud and GTEC U Track framing friction fitted to allow for adjustment
elements to suit system performance. during boarding.
LININGS
to be GTEC C Stud, fixed with web flat achieve performance and at a maximum
to structure using appropriate fixings at of 600mm centres
maximum 600mm centres and fixed to head
and track with appropriate GTEC Drywall Where wall height exceeds available
Screws (see screw selector, p334-335). GTEC Stud length splice two lengths
together ensuring overlap of 600mm
All GTEC C and Acoustic Studs to be 5mm for heights below 4m and 1000mm for
FIRE PROTECTION
shorter than floor to ceiling height or to suit heights above 4m.
deflection.
FINISHING
REFERENCE
BOARDING
PT-AS-201M- Horizontal joint reinforcement, single layer PT-AS-202M-Horizontal joint reinforcement, double layer
ISOMETRIC ISOMETRIC
joints on
alternating studs
joints on
alternating studs
ISOMETRIC
ISOMETRIC ISOMETRIC
77
INTRODUCTION
INTRODUCTION
OPENINGS
PT-AS-401P- Door frames – 25 to 100kg
PARTITIONS
GTEC C Stud
150mm
GTEC Intumescent Acoustic Sealant
150mm
GTEC Intumescent Acoustic Sealant
Timber stud
Up to 75kg Door
150mm
GTEC Intumescent Acoustic Sealant
LININGS
Up to 100kg Door Timber stud
FIRE PROTECTION
Note: Insulation not shown for clarity GTEC C Stud boxed
150mm
PLAN
GTEC Intumescent
Acoustic Sealant GTEC Intumescent
Acoustic Sealant
GTEC C Stud
screw fix
plasterboard
to stud
Insulation quilt
to suit required
performance
PLAN PLAN
GTEC C Studs to be used at corners and See Construction Details Drawings for further
junctions to provide flat web for fixing. guidance on arrangement and fixing.
CURVED PARTITIONS
GTEC Acoustic Studs are not suitable
for use in curved partitions.
i
REFERENCE FINISHING FIRE PROTECTION LININGS FLOORS AND CEILINGS PARTITIONS INTRODUCTION
INTRODUCTION 79
80 GTEC ACOUSTIC HOMESPAN PARTITION
GTEC ACOUSTIC
HOMESPAN
PARTITION SYSTEMS
The GTEC Acoustic Homespan system is a lightweight
partition specifically designed to meet Building Regulation
Part E where 40RwdB is required for internal partitions
in dwellings. This performance is achieved using 44mm
and 50mm GTEC Acoustic Homespan Studs and Tracks
and GTEC Acoustic Homespan Board without the need to
install insulation to achieve a 40RwdB rating.
WHERE TO USE:
GTEC Acoustic Homespan is an internal partition for
new-build domestic applications.
Benefits from all key features as detailed for GTEC C Stud, plus:
FEATURES BENEFITS
Achieves acoustic performance using narrow Maintains a low system footprint to minimise
width studs the effect on the room size
Achieves acoustic performance without the Quicker to install than other systems which use
need for insulation insulation to achieve the same performance
GTEC ACOUSTIC HOMESPAN PARTITION
81
INTRODUCTION
INTRODUCTION
PARTITIONS
GTEC Board
to suit required performance
GTEC U Track
LININGS
GTEC U Track
cut and fold to form head
to door opening (min. 150mm)
FIRE PROTECTION
m m
50m 0m
4 90
BOARDS
GTEC Acoustic Homespan Board See performance table, p43
900mm board to provide wall surface suitable
for finishing
FRAME
GTEC Acoustic Homespan Stud AHS44/RX, AHS50/RX
Metal profile for vertical frame elements with improved
acoustic performance
INSULATION
Mineral wool insulation See performance table
Increases fire and acoustic insulation performance supplied by others
FIX
GTEC Screws (as appropriate) See screw selector, p334-335
For connecting plasterboard and metal components
FINISHING
GTEC Corner and Edge beads n/a
Corner and edge reinforcement
83
INTRODUCTION
INTRODUCTION
SYSTEM GUIDANCE
See guidance in GTEC C Stud section and additional considerations given below:
FRAME
Select compatible size (e.g. 44mm stud Intermediate GTEC Acoustic Homespan
and 45mm track) GTEC Acoustic Homespan Studs, facing in same direction, to be
Stud, GTEC Acoustic Homespan Starter Stud friction fitted to allow for adjustment
and GTEC U Track framing elements to suit during boarding.
system performance.
PARTITIONS
All GTEC Studs to be 5mm shorter than
GTEC Acoustic Homespan is not suitable for floor to ceiling height.
heights above 2.8m and so does not require
deeper flange tracks. GTEC Acoustic Homespan Studs to be
at a maximum of 450mm centres.
Studs abutting structure to be GTEC Acoustic
Homespan Starter Studs fixed with web flat
INSULATION
Insulation is not required to achieve
40 RwdB performance with the GTEC
Acoustic Homespan system but may
be fitted to increase performance,
see performance tables p43.
LININGS
FIRE PROTECTION
FINISHING
REFERENCE
BOARDING
PT-AH-201M-Horizontal joint reinforcement, single layer PT-AH-203M-Board fixing – single layer
ISOMETRIC
ISOMETRIC ISOMETRIC
GTEC ACOUSTIC HOMESPAN PARTITION
85
INTRODUCTION
INTRODUCTION
OPENINGS
PT-AH-401P-Door frames – 25kg to 50kg door loads
PARTITIONS
GTEC C Stud 44-50mm wide
150mm
PLAN
LININGS
FIRE PROTECTION
FINISHING
REFERENCE
GTEC Acoustic
Homespan Stud
GTEC Intumescent
Acoustic Sealant
screw fix
plasterboard to stud
GTEC Acoustic
screw fix Homespan Starter Stud
plasterboard
to stud
GTEC Acoustic
Homespan Board
GTEC Board
to suit required
performance
GTEC Acoustic
Homespan Studs
PLAN PLAN
GTEC Acoustic Homespan Starter Studs to be See Construction Details Drawings for further
used at corners and junctions to provide flat guidance on arrangement and fixing.
web for fixing.
CURVED PARTITIONS
GTEC Acoustic Homespan Studs are not
suitable for use in curved partitions.
i
REFERENCE FINISHING FIRE PROTECTION LININGS FLOORS AND CEILINGS PARTITIONS INTRODUCTION
INTRODUCTION 87
88 GTEC RESILIENT BAR PARTITION
GTEC RESILIENT
BAR PARTITION
SYSTEMS
GTEC Resilient Bar is a versatile component that can be used with
a variety of partitions to provide improved acoustic performance.
GTEC Resilient Bar decouples the plasterboard from the metal frame
to reduce sound transmission with little increase in thickness. It is
fixed across the flanges of GTEC C Stud to provide a substrate for
the plasterboard away from the metal framing. Refer to the System
Performance Tables on pages 22 to 44 for full details.
See the GTEC Timber Partitions section for details on using the
GTEC Resilient Bar with timber construction.
WHERE TO USE:
GTEC Resilient Bar is used with the GTEC C Stud Partition system
in both domestic and commercial applications.
FEATURES BENEFITS
Easy to fit and install Reduced installation time compared with more
complex systems
89
INTRODUCTION
INTRODUCTION
PARTITIONS
GTEC Resilient Bar
provides fixing at 50mm maximum from soffit
GTEC Intumescent
Acoustic Sealant
LININGS
FIRE PROTECTION
GTEC Board
to suit required performance
GTEC Intumescent
FINISHING
Acoustic Sealant
BOARDS
All GTEC Boards See performance tables, p22-44
Provides wall surface suitable for finishing
FRAME
GTEC Resilient Bar RBD3000
Metal profile to provides acoustic separation of board
and frame
FINISHING
GTEC Corner and Edge beads n/a
Corner and edge reinforcement
91
INTRODUCTION
INTRODUCTION
SYSTEM GUIDANCE
See guidance in GTEC C Stud section and additional considerations given below:
FRAME
PT-RB-101S-Head – no deflection PT-RB-102S-Base junction v1
PARTITIONS
plasterboard performance
to Resilient Bar GTEC U Track
Deep Flange
fixed at 600mm
centres GTEC C Stud
GTEC Resilient
Bar inverted at
top of stud
GTEC Insulation
Hold GTEC Resilient Bar
max. 50mm from base
GTEC Resilient Bar to be installed on one side Uppermost GTEC Resilient Bar to be installed
of partition, across studs at 600mm vertical in inverted position at maximum of 50mm
centres and fixed to each stud with suitable from top of partition.
GTEC Drywall Screws (see screw selector,
p334-335). Lowest GTEC Resilient Bar to be installed at
maximum of 50mm from base of partition.
LININGS
FIRE PROTECTION
BOARDING
PT-RB-201M-Board fixing – double layer
GTEC Resilient Bar partition system is
screw fix board suitable for single and double layer boarding.
to resilient bar only
at max. 300mm centres Select base layer(s) and finishing layer(s)
GTEC Boards by consulting System Tables
(p22-44) and Product Specification (p294-
307) to achieve required performance. See
stagger joints High Performance Boards guide (p12-15) for
further selection information.
FINISHING
ISOMETRIC
ISOMETRIC Boards must not be fixed to studs or tracks to
ensure acoustic performance.
OPENINGS
PT-RB-401P-Door frame – 25-100 kg
150mm
GTEC Intumescent Acoustic Sealant
150mm
150mm
GTEC Intumescent Acoustic Sealant
PLAN
ISOMETRIC
GTEC RESILIENT BAR PARTITION
93
INTRODUCTION
INTRODUCTION
CORNERS AND JUNCTIONS
PT-RB-501P-Junction with masonry wall PT-RB-502P-Corner detail (External Resbar)
PARTITIONS
screw fix plasterboard
to resilient bar
PLAN PLAN
LININGS
GTEC Resilent Bar
to internal side of corner GTEC Intumescent
Acoustic Sealant
screw fix plasterboard
to resilient bar
GTEC Resilient Bar
FIRE PROTECTION
to suit required
performance
PLAN PLAN
PLAN
CURVED PARTITIONS
GTEC Resilient Bar is not suitable
for curved partitions.
FINISHING
REFERENCE
GTEC Twin Frame Partitions are constructed from two metal frames
in parallel, braced together with GTEC Acoustic V Brace and boarded
on the external sides only. Varying cavity size options help optimise
acoustic insulation and provide a service cavity. The GTEC Twin
Frame system is a lightweight, flexible option compared to traditional
masonry separating walls. Refer to the System Performance Tables on
pages 22 to 45 for full performance details.
WHERE TO USE:
GTEC Twin Frame systems are suitable for creating internal dividing
walls in both domestic and commercial applications with increased
performance and / or height requirements.
Benefits from all key features as detailed for GTEC C Stud, plus:
FEATURES BENEFITS
Cavity space between the two frames Provides high levels of acoustic,
thermal and fire performance
95
INTRODUCTION
INTRODUCTION
PARTITIONS
GTEC Intumescent Acoustic Sealant
at all perimeters of run
mineral wool
insulation to suit
required performance
LININGS
GTEC Insulation Hold
FIRE PROTECTION
GTEC Acoustic V Brace
to connect studs at
1500mm vertical centres FINISHING
GTEC Board
to suit required performance
REFERENCE
BOARDS
All GTEC Boards See performance table, p22-45
Provides wall surface suitable for finishing
FRAME
GTEC C Stud CS50/RX, CS60/RX, CS70/RX, CS90/RX,
Metal profile for vertical frame elements CS146/RX, CS70/B, CS90/B, CS146/B,
CS90/W, CS70/Y, CS90/Y, CS146/Y
INSULATION
Mineral wool insulation See performance table
Increases fire and acoustic insulation performance supplied by others
97
INTRODUCTION
INTRODUCTION
System Component System primary use Product Reference
FIX
GTEC Screws (as appropriate) See screw selector, p334-335
For connecting plasterboard and metal components
FINISHING
PARTITIONS
GTEC Corner and Edge beads n/a
Corner and edge reinforcement
LININGS
FIRE PROTECTION
SYSTEM GUIDANCE
FRAME
PT-CT-101S-Head – no deflection PT-CT-102S-Base
GTEC Intumescent
Acoustic Sealant GTEC Board
to suit required
performance
screw fix
plasterboard to track
GTEC C Stud
FINISHING
Acoustic Sealant
SECTION SECTION
FRAME continued
PT-CT-103S-Base with timber sole plate and screed
Insulation quilt
to suit required performance GTEC Board
to suit required performance
GTEC Intumescent
floating screed Acoustic Sealant
Resilient layer
SECTION
Select compatible size (e.g. 50mm stud and Timber sole plate may be required on uneven
52mm track) GTEC C Stud and GTEC U Track floors or where partition is constructed prior
framing elements to suit system performance. to screeding.
GTEC U Track Deep or Extra Deep Flange Protect base track from moisture with damp
to be used for heights greater than 4.2m proof membrane when situated on newly laid
and where deflection allowance is required concrete floors.
(see p105).
All GTEC C Studs to be 5mm shorter than
GTEC Twin Frame partition to be constructed floor to ceiling height except in case of
using two parallel track and stud frames deflection requirement (see p105).
braced together with GTEC Acoustic V Brace
at 1500mm vertical centres, mechanically Intermediate GTEC C Studs, facing in same
fixed to both studs with four appropriate direction, to be friction fitted to allow for
GTEC Drywall screws (see screw selector, adjustment during boarding.
p334-335).
GTEC C Studs to be at centres required to
Separate parallel frames as required by achieve performance and at a maximum of
system performance. Where frame separation 600mm centres.
is wider than GTEC Acoustic V Brace extend
Where wall height exceeds available
with additional length of GTEC Primary
GTEC Stud length splice two lengths
Channel or Dryliner Channel.
together ensuring overlap of
Studs abutting structure (starter studs) to 600mm for heights below 4m and
be fixed with web flat to structure using 1000mm for heights above 4m.
appropriate fixings at maximum 600mm
Acoustic break in slab for party walls
centres and fixed to head and track with
may be required.
appropriate GTEC Drywall Screws (see screw
selector, p334-335).
99
INTRODUCTION
INTRODUCTION
PT-CT-104M-Stud splice PT-CT-105M-V-brace fixing and extensions
PARTITIONS
screw fix at 150mm
centres both sides
600mm overlap
for height ≤ 4m
LININGS
1000mm overlap
for height > 4m
FIRE PROTECTION
ISOMETRIC ISOMETRIC
FINISHING
REFERENCE
INSULATION
PT-CT-151M-Insulation Hold
Insulation, if required, to be of type and
thickness to achieve performance and
All joints in outer layer
taped and jointed
installed in a continuous layer between studs.
Joints on opposite
faces offset and Where insulation may be expected to slump
staggered
between layers
suspend from GTEC Insulation Hold strips
fixed across studs, 150mm from top of
partition and at 1200mm vertical centres.
ISOMETRIC
BOARDING
PT-CT-201M-Board fixing – double layer PT-CT-202M-Horizontal joint reinforcement
screw fix
to fixing strap at
max. 300mm centres
GTEC Twin Frame partition system is suitable Boards to be mechanically fixed to studs
for single, double and multiple layer boarding. at 300mm centres using appropriate
GTEC Drywall Screws (see screw selector
Select base layer(s) and finishing layer(s) and guidance, p334-335).
GTEC Boards by consulting System Tables
(p22-45) and Product Specification (p294- Base layers of boarding may be temporarily
307) to achieve required performance. See fixed at 600mm centres providing final layer
High Performance Boards guide (p12-15) for is fixed through to stud at 300mm centres.
further selection information.
Board edges to be centred over studs.
Boards to be 5mm less than floor to
ceiling height except in case of deflection Stagger all board joints between layers.
requirement, see below.
Stagger all board joints on opposing sides
Strips of board 300mm wide or less to be of partition.
avoided by stud location rearrangement.
GTEC TWIN FRAME PARTITION
101
INTRODUCTION
INTRODUCTION
Over-height single layer boarding:
PARTITIONS
Over-height multiple layer boarding:
LININGS
GTEC C Studs
to suit required performance
GTEC Intumescent
Acoustic Sealant
FIRE PROTECTION
GTEC Board
10mm to suit required performance
PLAN
Form movement control joints at maximum Fix GTEC Movement Control Joint, butted
10m intervals in the partition run. end-to-end, to board with sheradised or
galvanised staples.
Form movement control joints where the
partition crosses a structural movement joint.
FINISHING
REFERENCE
OPENINGS
PT-CT-401P-Door frames – 25kg to 100kg door loads
25- 50kg
150mm
Up to 75kg
150mm
Up to 100kg
150mm
PLAN
C Stud
400mm
A
UXT
Min. 150mm
A
Section A-A
Max. 2m
Reinforcement as shown
in door frame plan to
Single Door 2400mm height of partition Double Door
103
INTRODUCTION
INTRODUCTION
Form openings following guidance in
Construction Detail Drawings to suit
door weights.
PARTITIONS
folding head track.
GTEC Board
to suit required
performance
GTEC Board
to suit required
performance
LININGS
screw fix
plasterboard GTEC Acoustic
V Brace
to stud
FIRE PROTECTION
GTEC Intumescent
Acoustic Sealant
GTEC Intumescent
Acoustic Sealant
GTEC Acoustic
V Brace
screw fix
plasterboard
to stud
Insulation to
suit required Insulation
performance to suit required
FINISHING
performance
REFERENCE
PLAN PLAN
Timber fillet
additional
insulation
GTEC Intumescent
Acoustic Sealant
screw fix plasterboard
to stud
PLAN PLAN
PT-CT-505P-Junction with Masonry – Plastered PT-CT-506P-Junction with Masonry – Dryliner & Direct Bond
GTEC Dryliner
skim plastered lining system
PLAN
PLAN PLAN
PLAN
105
INTRODUCTION
INTRODUCTION
HEAD DEFLECTION
PT-CT-601S-Deflection head, general arrangement
PARTITIONS
MINERAL WOOL & GTEC INTUMESCENT
CLOAKING ANGLE ACOUSTIC SEALANT
DETAIL DETAIL
packers cut precisely GTEC Intumescent
to track width Acoustic Sealant
=
Minimum 5mm overlap
of boards and packers
Minimum 15mm overlap
15mm
Stud cut short of track by of stud and track
deflection amount
=
minimum between track
and fixing
LININGS
FIRE PROTECTION
Note : Refer to the deflection table below
SECTION
Deflection Packer for all fire ratings: Track for all fire 30 & 60 mins 90 & 120 mins
required: ratings:
0-5mm 12.5mm GTEC Fire Board GTEC Deep Flange U GTEC Intumescent Mineral wool &
Track (UDT) Acoustic Sealant cloaking angle
6-10mm 15mm GTEC Fire Board GTEC Deep Flange U GTEC Intumescent Mineral wool &
Track (UDT) Acoustic Sealant cloaking angle
11-20mm 2x 12.5mm GTEC Fire Board or GTEC Deep Flange U GTEC Intumescent Mineral wool &
FINISHING
25mm GTEC Fire Core Board Track (UDT) Acoustic Sealant cloaking angle
21-25mm 2x 15mm GTEC Fire Board GTEC Deep Flange U GTEC Intumescent Mineral wool &
Track (UDT) Acoustic Sealant cloaking angle
26-32mm 3x 12.5mm GTEC Fire Board GTEC Deep Flange U GTEC Intumescent Mineral wool &
Track (UDT) Acoustic Sealant cloaking angle
33-40mm 3x 15mm GTEC Fire Board GTEC Extra Deep GTEC Intumescent Mineral wool &
REFERENCE
41-45mm 2x 25mm GTEC Fire Core Board or GTEC Extra Deep GTEC Intumescent Mineral wool &
4x 12.5mm GTEC Fire Board Flange U Track (UXT) Acoustic Sealant cloaking angle
PENETRATIONS
PT-CT-701P-Small diameter pipe penetration PT-CT-702E-Cable tray penetration
GTEC Intumescent
Acoustic Sealant
GTEC Intumescent
Acoustic Sealant
GTEC U Track
cut and bent
pipe or conduit
less than 50mm
in diameter
ELEVATION
PLAN ELEVATION
PT-CT-703M-Socket pad
M&E runs and other penetrating services
to be pre-planned to minimise or eliminate
penetrations through rated partitions.
ISOMETRIC
ISOMETRIC
GTEC TWIN FRAME PARTITION
107
INTRODUCTION
INTRODUCTION
PT-CT-704P-Multiple pipe penetrations
PARTITIONS
GTEC Fire Board
pattress
ELEVATION
GTEC Intumescent
Acoustic Sealant
150mm
LININGS
FIRE PROTECTION
void filled with 100mm minimum overlap
dense mineral wool
PLAN
FIXTURES
Consult fixture details in GTEC C Stud
Section (p67-69) for recommended
fixture provision.
FINISHING
FINISHING
All board joints to be taped, jointed GTEC Finish materials appropriate to board
or finished according to guidance in type to be used.
Finishing section (p276-291) to achieve
system performances.
REFERENCE
SYSTEM CONTINUITY
Bead of GTEC Intumescent Acoustic Sealant Full, imperforate system continuity to be
to be applied to perimeter of all runs and in maintained to achieve rated performances.
all other locations specified in Construction
Detail Drawings.
CURVED PARTITIONS
PT-CT-901M-Curved partition
GTEC C Stud
15
0m
m
Two C studs separated
by 150mm at start GTEC Flex Track Deep Flange
of straight section to create curve
ISOMETRIC
GTEC TWIN FRAME PARTITION
109
INTRODUCTION
INTRODUCTION
PT-CT-902M-Flex track component
Boards to be installed horizontally.
PARTITIONS
GTEC Flex Track Deep Flange
pre-cut at 50mm centres to
ISOMETRIC
LININGS
FIRE PROTECTION
GTEC Acoustic V Brace GTEC Contour Board
or other board to suit
PLAN
3.0 – 4.0 300 Dry 450 Wet 400 Wet 200 Wet
4.0 – 8.0 300 Dry 450 Wet 500 Wet 400 Wet
8.0 – 12.0 300 Dry 600 Dry 600 Dry 600 Wet
REFERENCE
GTEC TIMBER
PARTITION SYSTEMS
In timber frame construction or where traditional methods dominate,
a timber partition may be the preferred construction method.
GTEC Timber Partitions use timber studs and plates in place of metal
framing with GTEC Board screw fixed to complete the partition. Refer
to the System Performance Tables on pages 47 to 49 for full details.
WHERE TO USE:
GTEC Timber Partitions are used to create internal and separating
partitions within domestic applications.
FEATURES BENEFITS
Compatible with full range of GTEC boards Achieves excellent partition performance
Cavity space between two frames High levels of acoustic and fire performance
GTEC TIMBER PARTITION
111
INTRODUCTION
INTRODUCTION
PARTITIONS
GTEC Board
LININGS
GTEC Intumescent
Acoustic Sealant
FIRE PROTECTION
Timber sole plates
BOARDS
All GTEC Boards See performance tables, p47-49
Provides wall surface suitable for finishing
FRAME
Timber Supplied by others
Drywall partition framing
INSULATION
Mineral wool insulation See performance table supplied
Increases fire and acoustic insulation performance by others
FIX
GTEC High Thread Screws (as appropriate) See screw selector, p334-335
For attaching plasterboard to timber frame
FINISHING
GTEC Corner and Edge beads n/a
Galvanised metal reinforcements for corner
and edge protection
113
INTRODUCTION
INTRODUCTION
SYSTEM GUIDANCE
FRAME
PT-TS-101S-Head Detail (Load Bearing) PT-TS-102S-Head Detail (Non-Load Bearing)
Nogging
GTEC Intumescent
Acoustic Sealant
PARTITIONS
GTEC Board
GTEC Intumescent to suit required screw fix
screw fix plasterboard Acoustic Sealant plasterboard
performance
to timber to timber
Timber head track fixed
through to full height Timber head track
timber in ceiling fixed to full height
Mineral wool Mineral wool timber in ceiling
insulation as required insulation as required
SECTION SECTION
LININGS
Timber base track fixed to screw fix plasterboard
full height timber in floor Timber base track fixed to
to track
full height timber in floor
screw fix plasterboard GTEC Intumescent
Acoustic Sealant GTEC Intumescent
to track Acoustic Sealant
FIRE PROTECTION
coincide with partition
to reduce sound and fire path
SECTION SECTION
PT-TS-105P-End Detail
GTEC Board
to suit required performance
Timber Stud
PLAN
FRAME continued
PT-TT-101S-Head Detail PT-TT-102S-Base Detail
GTEC Board
to suit required
performance
GTEC Resilien Bar screw fix
plasterboard
to timber Mineral wool
Timber head plate insulation to
suit required
Timber packer
performance
GTEC Board
Mineral wool to suit required Timber head plate
insulation to performance
suit required Timber packer
performance screw fix
plasterboard GTEC Intumescent
to timber Acoustic Sealant
SECTION SECTION
Timber stud framing to be straight, plumb GTEC Resilient Bar option only:
and true. Studs to be fixed to timber sole
and head plates. GTEC Resilient Bar may be installed on one
side of partition, across studs at 600mm
All framing elements abutting structure to vertical centres and fixed to each stud with
be fixed at maximum 600mm centres using suitable GTEC Drywall Screws (see screw
appropriate fixings. selector, p334-335).
Studs to have minimum board bearing width Uppermost GTEC Resilient Bar to be installed
of 38mm. in inverted position at maximum of 50mm
from top of partition.
Studs to be arranged at maximum 400mm
centres for 9.5mm board and maximum Lowest GTEC Resilient Bar to be installed at
600mm centres for 12.5 and 15mm board. maximum of 50mm from base of partition.
GTEC TIMBER PARTITION
115
INTRODUCTION
INTRODUCTION
INSULATION
PT-TS-151M-Insulation Hold
PARTITIONS
FLOORS AND CEILINGS
ISOMETRIC
LININGS
FIRE PROTECTION
BOARDING
PT-TS-201M-Board fixing – single layer PT-TS-202M-Overheight partition – single layer
opposing joints
on alternating studs
ISOMETRIC ISOMETRIC
BOARDING continued
PT-TS-203M-Overheight partition – double layer PT-TT-201M-Board fixing – double layer
screw fix
to timber studs at
max. 300mm centres Stagger joints
between layers
ISOMETRIC ISOMETRIC
ISOMETRIC
screw fix
to timber studs at
max. 300mm centres
ISOMETRIC ISOMETRIC
GTEC Timber Single Stud partition system is Boards to be mechanically fixed to studs
suitable for single, double and multiple layer at 300mm centres using appropriate
boarding. GTEC High-Thread Drywall Screws (see
screw selector, p334-335).
Select base layer(s) and finishing layer(s)
GTEC Boards by consulting System Base layers of boarding may be temporarily
Performance Tables (p47-49) and Product fixed at 600mm centres providing final layer
Specification (p294-307) to achieve required is fixed through to stud at 300mm centres
performance. See High Performance
Boards guide (p12-15) for further selection Board edges to be centred over studs.
information.
Stagger all board joints between layers.
Boards to be 5mm less than floor to ceiling
Stagger all board joints on opposing sides
height.
of partition.
Strips of board 300mm wide or less to be
avoided by stud arrangement.
GTEC TIMBER PARTITION
117
INTRODUCTION
INTRODUCTION
Over-height single layer boarding: GTEC Resilient Bar option only:
PARTITIONS
Over-height multiple layer boarding: All layers of boarding to be fixed at
300mm centres.
Where partition height exceeds board
height for double or multiple layer boarding Boards must not be fixed to studs or
fix outer layer of boards to continuous tracks to ensure acoustic performance.
band of GTEC Flat Strap FS50/RX behind
OPENINGS
PT-TS-401P-Door jamb PT-TT-401P-Door jamb
GTEC Intumescent
Acoustic Sealant GTEC Corner 90º External /
GTEC Flex Tape
LININGS
Timber stud strips of board fixed to stud
GTEC Board
to suit required
performance GTEC Board
to suit required performance
FIRE PROTECTION
PLAN PLAN
GTEC Intumescent
Acoustic Sealant
Timber Stud
as required
screw fix
plasterboard to stud
GTEC Intumescent
Acoustic Sealant
PLAN PLAN
GTEC Intumescent
Acoustic Sealant
Timber Stud fixed through
to twin frame studs Timber Stud
continuos boarding
GTEC Intumescent
Acoustic Sealant screw fix plasterboard
to stud
GTEC Board
to suit required performance
PLAN PLAN
119
INTRODUCTION
INTRODUCTION
HEAD DEFLECTION SYSTEM CONTINUITY
Timber stud partitions are not generally Bead of GTEC Intumescent Acoustic Sealant
compatible with deflection head requirements. to be applied to perimeter of all runs and in
all other locations specified in Construction
Detail Drawings.
PENETRATIONS
GTEC Intumescent Acoustic Sealant to seal
M&E runs and other penetrating services all other acoustic or air paths to prevent fire/
to be pre-planned to minimise or eliminate smoke spread and acoustic transmission.
PARTITIONS
penetrations through rated partitions.
Full, imperforate system continuity to be
Any penetrations must be fully sealed maintained to achieve rated performances.
with GTEC Intumescent Acoustic Sealant
or other fire resisting material as specified
in Construction Detail Drawings.
FIXTURES
See guidance on p67-69 for further information.
FINISHING
All board joints to be taped, jointed
or finished according to guidance in
Finishing section (p276-291) to achieve
system performances.
LININGS
GTEC Finish materials appropriate to
board type to be used.
FIRE PROTECTION
FINISHING
REFERENCE
PARTITIONS
CEILINGS
LININGS
GTEC Ceiling Systems to Timber Floors 123
GTEC Dryliner Ceiling Systems to Concrete Soffit 127
GTEC Separating Floor Systems 128
FIRE PROTECTION
GTEC Pregybel MF Ceiling Systems 131
GTEC Suspended MF Ceiling Systems to Timber Floors 133
GTEC Suspended MF Ceiling Systems to Protect Structure 135
GTEC Mass Barrier Ceilings 136
GTEC Acoustic Floor Systems 137
i
122 GTEC FLOORS AND CEILINGS – PERFORMANCE TABLES
123
INTRODUCTION
INTRODUCTION
GTEC CEILING SYSTEMS TO TIMBER FLOORS
PARTITIONS
Ceiling Inner Layer(s): – 37 233 30 38 77
Ceiling Outer Layer(s): 30
1x 15mm GTEC Standard Board
Accessories: –
Insulation: –
Structure: 47mm x 200mm joists at
400mm centres without noggings
LININGS
1x 12.5mm GTEC Standard Board
Accessories: –
Insulation: 100mm 10.5kg/m3 glass mineral wool
Structure: 47mm x 200mm joists at
400mm centres with noggings
Flooring Make-up: 22mm tongue and
grooved chipboard
FIRE PROTECTION
RTC 061: Direct-to-Timber – see p162
Ceiling Inner Layer(s): – 43 254 30 40 76
Ceiling Outer Layer(s): 30
1x 15mm GTEC Standard Board
Accessories: Single GTEC Resilient Bar at max.
450mm centres
Insulation: –
Structure: 47mm x 200mm joists at
450mm centres
Flooring Make-up: 22mm tongue and
grooved chipboard
grooved chipboard
125
INTRODUCTION
INTRODUCTION
System Minimum Fire Perf. Acoustic Impact
Weight Thickness BS476-21 Perf. Sound
BS EN Rw dB Insulation
1365-2 (Ctr where
(kg/m2) (mm) (mins) applicable) (Lnw dB)
System Ref. Component
PARTITIONS
Ceiling Inner Layer(s): 50 252 60 43 72
1x 15mm GTEC Standard Board 30
Ceiling Outer Layer(s):
1x 15mm GTEC Standard Board
Accessories: –
Insulation: –
Structure: 47mm x 200mm joists at
LININGS
Ceiling Inner Layer(s): Existing Lath & Plaster 54 – 30 47 71
with Chicken Wire & Battens at 400mm centres 30
Ceiling Outer Layer(s):
1x 12.5mm GTEC Standard Board
Accessories: –
Insulation: –
Structure: 47mm x 200mm joists at
450mm centres without noggings
FIRE PROTECTION
Flooring Make-up: 22mm tongue and
grooved chipboard
grooved chipboard
REFERENCE
127
INTRODUCTION
INTRODUCTION
GTEC DRYLINER CEILING SYSTEMS
TO CONCRETE SOFFIT
System Minimum Fire Perf. Acoustic Impact
Weight Thickness BS476-21 Perf. Sound
BS EN Rw dB Insulation
1365-2 (Ctr where
(kg/m2) (mm) (mins) applicable) (Lnw dB)
System Ref. Component
PARTITIONS
Ceiling Inner Layer(s): – 11 – – – –
Ceiling Outer Layer(s): –
1x 12.5mm GTEC Standard Board
Accessories: GTEC Dryliner Channel RD1 at
450mm max. centres
Insulation: –
Structure: Any Concrete Soffit
LININGS
Ceiling Outer Layer(s): –
1x 12.5mm GTEC Fire Board
Accessories: GTEC Dryliner Channel RD1 at
450mm max. centres
Insulation: 50mm 24kg/m3 glass mineral wool
Structure: Any Concrete Soffit
Flooring Make-up: –
FIRE PROTECTION
RDC 019: Dryliner – see p154
Ceiling Inner Layer(s): 23 – 60 – –
1x 12.5mm GTEC Fire Board –
Ceiling Outer Layer(s):
1x 12.5mm GTEC Fire Board
Accessories: GTEC Dryliner Channel RD1 at
450mm max. centres
Insulation: 50mm 24kg/m3 glass mineral wool
Structure: Any Concrete Soffit
Flooring Make-up: –
FINISHING
REFERENCE
RTC 025
Ceiling Inner Layer(s): 1x 19mm GTEC Plank 70 323 60 61, -11 54
Ceiling Outer Layer(s): 1x 12.5mm GTEC dB Board 60
Accessories: Single GTEC Resilient Bar at max.
450mm centres
Insulation: 100mm 10.5kg/m3 glass mineral wool
Structure: 47mm x 200mm joists at
600mm centres
Flooring Make-up: 18mm tongue and
grooved chipboard
(from external layer)
on 19mm GTEC Plank
on 30mm 150kg/m3 rock mineral wool
on 12mm plywood or OSB
RTC 049
Ceiling Inner Layer(s): 1x 15mm GTEC dB Board 71 – 60 60, -9 55
Ceiling Outer Layer(s): 1x 15mm GTEC dB Board 60
Frame: GTEC MF Ceiling Channels at max.
450mm centres
Accessories: GTEC Frame should be screw fixed
Insulation: 100mm 10.5kg/m3 glass mineral wool
Structure: 47mm x 200mm joists at
400mm centres
Flooring Make-up: 18mm tongue and
grooved chipboard
(from external layer)
on 19mm GTEC Plank
on 30mm 150kg/m3 rock mineral wool
on 12mm plywood or OSB
RTC 050
Ceiling Inner Layer(s): 1x 15mm GTEC dB Board 71 317 60 60, -9 55
Ceiling Outer Layer(s): 1x 15mm GTEC dB Board 60
Accessories: Single GTEC Resilient Bar at max.
450mm centres
Insulation: 100mm 10.5kg/m3 glass mineral wool
Structure: 47mm x 200mm joists at
400mm centres
Flooring Make-up: 18mm tongue and
grooved chipboard
(from external layer)
Spot bonded on GTEC 15mm dB Board
on 30mm 150kg/m3 rock mineral wool
on 12mm plywood or OSB
129
INTRODUCTION
INTRODUCTION
System Minimum Fire Perf. Acoustic Impact
Weight Thickness BS476-21 Perf. Sound
BS EN Rw dB Insulation
1365-2 (Ctr where
(kg/m2) (mm) (mins) applicable) (Lnw dB)
System Ref. Component
PARTITIONS
Ceiling Inner Layer(s): 1x 15mm GTEC Fire Board 72 - 60 Robust Robust
Ceiling Outer Layer(s): 1x 15mm GTEC Fire Board 60 Detail Detail
Accessories: Single GTEC Resilient Bar at max. Solution Solution
450mm centres
Insulation: 100mm 10-33kg/m3 glass mineral wool
Structure: min. 240mm engineered timber I-joists
Flooring Make-up: 18mm tongue and grooved
RSF 002
Ceiling Inner Layer(s): 1x 15mm GTEC dB Board 44 271 60 65, -12 53
Ceiling Outer Layer(s): 1x 15mm GTEC dB Board 60
Accessories: Single GTEC Resilient Bar at max.
450mm centres
Insulation: 100mm 23kg/m3 glass mineral wool
Structure: 150mm Structural Steel Joists at
400mm centres
Flooring Make-up: 18mm tongue and grooved
LININGS
chipboard
(from external layer)
Spot bonded on GTEC 15mm dB Board
on 30mm 120kg/m3 Rock Slab Insulation
on 11mm OSB Sterling T&G Board
RSF 003
FIRE PROTECTION
Ceiling Inner Layer(s): 1x 15mm GTEC dB Board 112 313 60 61, -7 57
Ceiling Outer Layer(s): 1x 15mm GTEC dB Board 60
Accessories: Single GTEC Resilient Bar at max.
450mm centres
Insulation: 100mm 10kg/m3 glass mineral wool
Structure: 150mm Structural Steel Joists at
400mm centres
Flooring Make-up: 40mm Gyvlon Screed on
6mm Ethafoam
(from external layer)
on 20mm OSB Sterling Board
E-FC-1
Applicable Ceilings: – – – Robust Robust
(CT1) Metal ceiling system: – Detail Detail
GTEC MF Ceiling system providing Solution Solution
100mm (min) ceiling void with one layer
12.5mm GTEC Standard Board
(CT2) Timber battens and counter battens:
50mm x 50mm softwood battens with 50mm
x 50mm counter battens below and one layer
12.5mm GTEC Standard Board
(CT3) Metal ceiling system (shown):
GTEC Dryliner SR or MF ceiling system
providing 75mm (min) ceiling void with
one layer 10+kg/m2 GTEC Board
(CT4) Timber battens and resilient bar:
Ceiling CT3 shown 50mm x 50mm softwood with GTEC resilient
bar RBD3000 mounted at 90° to softwood
battens at 450mm c/c (max) and one layer
12.5mm GTEC E Board
Floating floor: 18mm tongue and groove
floorboards on resilient composite timber
battens type FFT1
Screed: 40mm sand/cement or similar,
minimum 80kg/m2
Structural floor: 150mm minimum precast
concrete planks, minimum 300kg/m2
E-FC-2
Applicable Ceilings: – – – Robust Robust
Metal ceiling system (shown): – Detail Detail
GTEC Dryliner SR or MF ceiling system Solution Solution
providing 75mm (min) ceiling void with
one layer 10+kg/m2 GTEC Board
Timber ceiling system:
Any ceiling system providing 75mm void
with one layer 12.5mm GTEC E Board
Floating floor: 18mm tongue and groove
floorboards on 25mm mineral wool batt
insulation density 150kg/m3 type FFT4
Structural floor: 250mm minimum in-situ
Metal ceiling shown concrete slab, minimum 2400kg/m3
without screed
131
INTRODUCTION
INTRODUCTION
GTEC PREGYBEL MF CEILING SYSTEMS
PARTITIONS
Ceiling Inner Layer(s): – 12 B 0.80
Ceiling Outer Layer(s): 1x GTEC Pregybel C10no8
Frame: GTEC MF Ceiling Channels at Max 600mm centres
Accessories: GTEC Frame should be screw fixed
Insulation: 75mm glass mineral wool and 600mm void
Structure: Any suitable soffit
LININGS
Structure: Any suitable soffit
FIRE PROTECTION
Insulation: 300mm void
Structure: Any suitable soffit
133
INTRODUCTION
INTRODUCTION
GTEC SUSPENDED MF CEILING SYSTEMS
TO TIMBER FLOORS
System Minimum Fire Perf. Acoustic Impact
Weight Thickness BS476-21 Perf. Sound
BS EN Rw dB Insulation
1365-2 (Ctr if
(kg/m2) (mm) (mins) applicable) (Lnw dB)
System Ref. Component
PARTITIONS
Ceiling Inner Layer(s): – 33 n/a 30 43 72
Ceiling Outer Layer(s): 1x 12.5mm GTEC E Board 30
Frame: GTEC Ceiling Channels at max.
450mm centres
Accessories: GTEC Connecting Clips
Insulation: –
Structure: 47mm x 200mm Joists at 600mm
LININGS
RCC 012: Suspended MF – see p138
Ceiling Inner Layer(s): 1x 12.5mm GTEC E Board 42 n/a 60 46 69
Ceiling Outer Layer(s): 1x 12.5mm GTEC E Board 30
Frame: GTEC Ceiling Channels at max.
450mm centres
Accessories: GTEC Frame should be screw fixed
FIRE PROTECTION
Insulation: 100mm 10.5kg/m3 glass mineral wool
Structure: 47mm x 200mm Joists at
600mm centres
Floor: Min. 18mm tongue and grooved
boarding or similar
FINISHING
REFERENCE
135
INTRODUCTION
INTRODUCTION
GTEC SUSPENDED MF CEILING SYSTEMS
TO PROTECT STRUCTURE
System Fire Perf. Fire Perf. Fire Perf. Acoustic Impact
Weight BS476-21 BS476-23 BS EN Perf. Sound
BS476-22 1364-2 Rw dB Insulation
BS EN (Ctr if
(kg/m2) (mins) (mins) 1365-2 applicable) (Lnw dB)
System Ref. Component (mins)
PARTITIONS
Ceiling Inner Layer(s): – 11 – – – – –
Ceiling Outer Layer(s): – –
1x 12.5mm GTEC Standard Board
Frame: GTEC Ceiling Channels at
max. 450mm centres
Accessories: GTEC Connecting Clips
Insulation: –
LININGS
Ceiling Outer Layer(s): – –
1x 12.5mm GTEC Fire Board
Frame: GTEC Ceiling Channels at
max. 450mm centres
Accessories: GTEC Connecting Clips
Insulation: 50mm 24kg/m3 glass
mineral wool
Structure: Any suitable soffit
FIRE PROTECTION
RCC 019: Suspended MF – see p138
Ceiling Inner Layer(s): 26 – 60 30 – –
1x 12.5mm GTEC Fire Board – –
Ceiling Outer Layer(s):
1x 12.5mm GTEC Fire Board
Frame: GTEC Ceiling Channels at
max. 450mm centres
Accessories: GTEC Frame should be
screw fixed
Insulation: 50mm 10.5kg/m3 glass
mineral wool
Structure: Any suitable soffit
FINISHING
REFERENCE
137
INTRODUCTION
INTRODUCTION
GTEC ACOUSTIC FLOOR SYSTEMS
PARTITIONS
Ceiling Inner Layer(s): 1x 15mm GTEC dB Board 60 60 63, -10 54
Ceiling Outer Layer(s): 1x 15mm GTEC dB Board 60
Accessories: Single GTEC Resilient Bar at max.
450mm centres
Insulation: 100mm 10.5kg/m3 glass mineral wool
Structure: 47mm x 200mm joists at 450mm centres
Floor Inner Layer(s): 1x 15mm GTEC dB Board on
LININGS
FIRE PROTECTION
FINISHING
Any alterations may impair the quoted performance. Contact Technical Services for further system configurations and their
resulting performances.
Insulation shown may be replaced with thicker and/or heavier quilt material without impairing the quoted performances.
For maximum framing centres, joist connector and bracket centres and loading see tables within system guidance pages.
GTEC SUSPENDED
MF CEILING
SYSTEMS
The GTEC Suspended MF Ceilings are used to create ‘false ceilings’
which house services between the ceiling and soffit. The large voids
created also improve acoustic, fire and thermal performance.
WHERE TO USE:
GTEC Suspended MF Ceilings are used for commercial
applications where services are required below the soffit.
FEATURES BENEFITS
High acoustic, fire and thermal capabilities Required performance levels are easily achieved
139
INTRODUCTION
INTRODUCTION
PARTITIONS
FLOORS AND CEILINGS
Insulation to suit
required performance GTEC Connecting Clip
for single layer systems only
fix channels back to back if required
minimum overlap of 150mm
LININGS
splice ceiling channel
if required minimum
FIRE PROTECTION
overlap of 150mm
GTEC Board
to suit required performance
BOARDS
All GTEC Boards See performance tables, p133-136
Provides wall surface suitable for finishing
FRAME
GTEC Ceiling Channel MFCC50
Steel channel to support boards
INSULATION
Mineral wool insulation See performance tables
Increases fire and acoustic insulation performance supplied by others
FIX
GTEC Drywall Screws (as appropriate) See screw selector, p334
For connecting plasterboard and metal components
FINISHING
GTEC Joint Tape n/a
Joint reinforcement in conjunction with
GTEC Jointing Compounds
141
INTRODUCTION
INTRODUCTION
SYSTEM GUIDANCE
FRAME
FC-MF-101S-Ceiling perimeter
Max.
900mm GTEC Metal Angle
PARTITIONS
GTEC Primary
Channel
GTEC Board
Board fixed to GTEC Edge to suit required
Channel at 150mm centres performance
SECTION
LININGS
es
lic
sp
een
tw
be
n. Primary Channel Splice
mi
mm
00
12
n
mi
FIRE PROTECTION
0 mmap
15 verl
o
ISOMETRIC
FRAME continued
GTEC Ceiling Channels at maximum 450mm GTEC Primary Channels may be spliced
centres to be located into GTEC Edge if necessary by fixing back-to-back with
Channel and fixed at right angles to GTEC minimum four appropriate GTEC Drywall
Primary Channel. Screws.
Fixing between Ceiling and Primary channels GTEC Ceiling Channels may be jointed by
to be made using appropriate GTEC Drywall overlapping profiles by minimum 150mm
Screws. and fixing with minimum four appropriate
GTEC Drywall Screws.
GTEC Connecting Clips may only be used to
connect GTEC Ceiling Channel to Primary
Channel in single board layer systems with
no additional loadings. GTEC Connecting
Clips to be alternated in direction to
counteract any movement.
INSULATION
Any insulation to be of type and thickness
to achieve performance and installed in a
continuous layer between primary channels
and over ceiling channels and boards.
GTEC SUSPENDED MF CEILING
143
INTRODUCTION
INTRODUCTION
BOARDING
FC-MF-201M & 202M Board Layout
SINGLE LAYER
PARTITIONS
GTEC Ceiling Channel
DOUBLE LAYER
LININGS
stagger joints and
fixings between layers
FIRE PROTECTION
GTEC Edge Channel
PLAN
performance. See High Performance Boards centres at cut edges, using appropriate GTEC
guide p12 for further selection information. Drywall Screws. See screw selector p334.
Boards to span across GTEC Ceiling Channels. Board joints to be staggered between layers.
Joints between boards must occur at centre
of channels. Any GTEC Fire Board, or other GTEC Type
F (BS EN 520) board, required by the
REFERENCE
Board ends and joints to be centred over system performance, to be installed as the
channels. outermost/finishing layer.
SECTION SECTION
Form movement control joints at maximum Fix GTEC Movement Control Joint, butted
10m intervals in any direction in ceiling run. end-to-end, to board with sheradised or
galvanised staples.
Form movement control joints where ceiling
crosses a structural movement joint. Follow measures to ensure fire resistance and
stability as shown in Construction Details.
OPENINGS
FC-MF-401M-Opening in ceiling
145
INTRODUCTION
INTRODUCTION
HEIGHT CHANGE & JUNCTIONS
FC-MF-501S-Junction of partition to ceiling FC-MF-502S-Junction of ceiling to partition
PARTITIONS
Ceiling boards separated at
Track fixed through
partition heads to reduce
to channel
sound transmission
GTEC Edge Channel
fixed through to stud GTEC Intumescent
Acoustic Sealant
GTEC Intumescent
Acoustic Sealant
GTEC Primary Channel
Max. 600mm
GTEC Primary
LININGS
Channel
GTEC Edge Channel
FIRE PROTECTION
GTEC Corner 90º GTEC Corner 90º
External / GTEC Flex Tape GTEC Ceiling Channel
External / GTEC Flex Tape
SECTION SECTION
Abutting partitions to coincide with and fix Where ceiling abuts partition fix
to GTEC Ceiling Channel, install additional GTEC Edge Channel through to stud.
intermediate ‘pick-up’ channels if required.
Form 90° junction in ceiling by fixing
Separate boards at partition head to reduce GTEC Edge Channels at right angle with
sound transmission. GTEC Ceiling Channel spanning vertically
as required. Hangers to be positioned at
maximum 150mm from change in height.
FINISHING
REFERENCE
FIXTURES FINISHING
Where possible fixtures and loadings to be All board joints to be taped, jointed or
suspended from structural soffit and not finished according to guidance in Finishing
GTEC Suspended MF Ceiling system. section (p276-291) to achieve system
performances. Where a ceiling is not intended
Loads suspended from ceiling to be fixed to to be decorated GTEC Intumescent Sealant to
frame not boards. Framing centres to suit be used to seal board joints.
total load, see guidance on centres in ‘Frame’
guidance section, and appropriate fixings GTEC Finish materials appropriate to board
selected to suit full loadings. type to be used.
Any penetrations must be fully sealed GTEC Intumescent Acoustic Sealant to seal
with GTEC Intumescent Acoustic Sealant all other acoustic or air paths to prevent fire/
or other fire and sound resisting material. smoke spread and acoustic transmission.
GTEC SUSPENDED MF CEILING
147
INTRODUCTION
INTRODUCTION
ACOUSTIC MASS BARRIER CEILINGS
FC-MF-002S-Phonissimo Acoustic Hanger – general arrangement FC-MF-003M-Phonissimo Acoustic Hanger – assembly
M6 threaded rod by
M6 threaded rod by others
others at 1200mm centres
fitted into GTEC Phonissimo
PARTITIONS
GTEC Heavy Gauge Primary
Channel at 900mm centres
SECTION ISOMETRIC
GTEC Phonistar
GTEC Phonistar Resilient Acoustic Hanger
Hanger at 1200mm centres
GTEC Heavy Gauge
Primary Channel
LININGS
GTEC Heavy Gauge Primary
Channel at 900mm centres Hole drilled in channel
to receive phoniostar rod
Square washer
GTEC dB Board
to suit required performance
Nut to secure end of rod
FIRE PROTECTION
GTEC Ceiling Channel
at 400mm centres
SECTION ISOMETRIC
For Acoustic Mass Barrier system GTEC Heavy Gauge Primary Channel UT52/Y
configurations suspend frame from to be used instead of GTEC Primary Channel.
GTEC Phonistar or GTEC Phonissimo
hangers at maximum 1200mm centres
using M6 threaded rod.
GTEC PREGYBEL MF
CEILING SYSTEMS
The GTEC Pregybel MF Ceiling system is used for creating sound
absorbing ceilings to control sound reflection in larger spaces,
creating a more comfortable level of sound and improved audibility.
WHERE TO USE:
GTEC Pregybel MF ceilings are used in commercial applications
where large, hard-surfaced and uninterrupted spaces would
otherwise suffer from echoing.
FEATURES BENEFITS
Variable cavity depth Cavity size can be optimised for service and
insulation requirements
Easy to install
149
INTRODUCTION
INTRODUCTION
PARTITIONS
FLOORS AND CEILINGS
Glass Mineral wool insulation
to suit required performance
LININGS
FIRE PROTECTION
GTEC MF Suspended
Ceiling System
FINISHING
REFERENCE
BOARDS
All GTEC Boards See performance tables, p131-132
Provides wall surface suitable for finishing
FRAME
GTEC Ceiling Channel MFCC50
Steel channel to support boards.
INSULATION
Mineral wool insulation See performance tables
Increases acoustic absorption supplied by others
FIX
GTEC Drywall Screws (as appropriate) See screw selector, p334
For connecting plasterboard and metal components
FINISHING
GTEC Joint Tape n/a
Joint reinforcement in conjunction with
GTEC Jointing Compounds
151
INTRODUCTION
INTRODUCTION
SYSTEM GUIDANCE
See guidance in GTEC Suspended MF section and additional considerations given below:
FRAME
FC-PG-101S-Pregybel Secondary Ceiling
PARTITIONS
GTEC Ceiling Channel
screw fixed at 400mm centres
GTEC Board
to suit required performance
LININGS
FIRE PROTECTION
INSULATION
Any insulation to be of type and thickness
to achieve performance and installed in a
continuous layer between primary channels
and over ceiling channels and boards.
FINISHING
REFERENCE
BOARDING
FC-PG-201E-Pregybel board designs
25
12
20 10
10
30
15
30
15
80
5
80
10
153
INTRODUCTION
INTRODUCTION
FC-PG-501S-Pregybel Ceiling Height Change FC-PG-002S-Pregybel Standalone Bulkhead
GTEC Primary
Channel
GTEC C Stud
PARTITIONS
Brace diagonally
with GTEC U Track
GTEC Edge Channel
600mm
screw fixed at 400mm centres
Max.
GTEC Edge Channel GTEC U Track
SECTION SECTION
PENETRATIONS FINISHING
M&E runs and other penetrating services All board joints to be taped, jointed or finished
to be pre-planned to minimise or eliminate according to guidance in Finishing section
penetrations through rated ceilings. (p276-291) to achieve system performances.
Any penetrations must be fully sealed with GTEC Pregybel Board, once sealed,
GTEC Intumescent Acoustic Sealant or other to be painted with rollers to prevent
fire and sound resisting material. paint blocking tissue backing and
LININGS
reducing absorption capacity.
FIRE PROTECTION
Bead of GTEC Intumescent Acoustic Sealant
to be applied to perimeter of all runs and in Select GTEC Pregybel Board according to
all other locations specified in Construction acoustic performance required and desired
Detail Drawings to prevent dust accumulation. perforation pattern.
GTEC DRYLINER
CEILING SYSTEMS
The GTEC Dryliner Ceiling system is a simple, quick and
cost-effective method for constructing a true, flat ceiling,
even when connecting to uneven joists or concrete soffits.
It also creates a small cavity to accommodate services.
WHERE TO USE:
GTEC Dryliner Ceilings are used for both domestic and commercial
applications for either new build or renovation projects.
FEATURES BENEFITS
Improved fire protection for timber joists Cost effective solution for achieving required
performance
No direct connection between board and joists Reduces risk of plasterboard cracking from
movement of wooden joists
GTEC DRYLINER CEILING
155
INTRODUCTION
INTRODUCTION
PARTITIONS
GTEC Dryliner Bracket
GTEC Dryliner Channel
GTEC Intumescent
Acoustic Sealant
GTEC Board
to suit required
performance
LININGS
FIRE PROTECTION
Note: 600mm joist centres with noggings shown.
FINISHING
REFERENCE
BOARDS
All GTEC Boards See performance tables, p127
Provides wall surface suitable for finishing
FRAME
GTEC Dryliner Channel RD1
A galvanised steel furring channel for
plasterboard fixing
INSULATION
Mineral wool insulation See performance tables
Increases fire and acoustic insulation performance supplied by others
FIX
GTEC Drywall Screws (as appropriate) See screw selector, p334
For connecting plasterboard and metal components
FINISHING
GTEC Joint Tape n/a
Joint reinforcement in conjunction with
GTEC Jointing Compounds
157
INTRODUCTION
INTRODUCTION
SYSTEM GUIDANCE
FRAME
FC-DC-101E-Dryliner cavity sizes FC-DC-102S-Ceiling perimeter
PARTITIONS
GTEC Dryliner Channel
GTEC Intumescent
Acoustic Sealant
SECTION
LININGS
suit cavity depth required:
FIRE PROTECTION
bracket as required
SECTION
INSULATION
Any insulation to be of type and thickness to continuous layer between brackets and over
achieve performance and tightly installed in a channels.
BOARDING
FC-DC-201P & 202P-Single boarding and double layer boarding
SINGLE LAYER
DOUBLE LAYER
PLAN
GTEC DRYLINER CEILING
159
INTRODUCTION
INTRODUCTION
GTEC Dryliner Ceiling system is suitable for Boards to be mechanically fixed to
single and double layer boarding. GTEC Dryliner Track at 150mm centres
using appropriate GTEC Drywall Screws.
Select base layer(s) and finishing layer(s) See screw selector p334.
GTEC Boards by consulting System
Performance Tables (p133-136) and Product Boards to be mechanically fixed to GTEC
Specification (p294-307) to achieve required Dryliner Channels at 230mm centres in field
performance. See High Performance Boards of board or at bound edges and at 150mm
PARTITIONS
guide p12 for further selection information. centres at cut edges, using appropriate GTEC
Drywall Screws. See screw selector p334.
Boards to span across GTEC Dryliner
Channels with bound edges at right Board joints to be staggered between layers.
angles to channels.
Any GTEC Fire Board, or other GTEC
Max. Max.
50mm 50mm
LININGS
FIRE PROTECTION
GTEC Movement
Control Joint 50mm Rock Mineral wool
insulation 40kg/m3
10mm (if fire rated system)
SECTION
Form movement control joints at maximum Fix GTEC Movement Control Joint, butted
10m intervals in any direction in ceiling run. end-to-end, to board with sheradised or
galvanised staples.
Form movement control joints where ceiling
crosses a structural movement joint. Follow measures to ensure fire resistance and
stability as shown in Construction Details.
FINISHING
REFERENCE
Max. Max.
150mm 150mm
GTEC Intumescent
Acoustic Sealant
screw fix track
through to channel
GTEC Intumescent
Acoustic Sealant
GTEC Partition
System to suit
GTEC Partition required performance
System to suit
required performance
SECTION SECTION
GTEC Intumescent
Acoustic Sealant
GTEC Dryliner
GTEC Dryliner Track Channel
fix to track
at 150mm centres
GTEC Corner 90º External /
GTEC Flex Tape
SECTION SECTION
Abutting partitions to coincide with and fix Form 90° junction in ceiling with GTEC
to GTEC Dryliner Channel, install additional Dryliner Track as corner reinforcement or
intermediate ‘pick-up’ channels with brackets position GTEC Dryliner brackets to receive
where required. edge board along legs.
161
INTRODUCTION
INTRODUCTION
FIXTURES SYSTEM CONTINUITY
Fixtures and loadings to be suspended from Full, imperforate system continuity to be
structural soffit/joist and not GTEC Dryliner maintained to achieve rated performances.
Ceiling system.
Bead of GTEC Intumescent Acoustic Sealant
Any services or installations in ceiling void to to be applied to perimeter of all runs and in
be supported by structural soffit/joist and not all other locations specified in Construction
GTEC Dryliner Ceiling System. Detail Drawings.
PARTITIONS
GTEC Intumescent Acoustic Sealant to seal
PENETRATIONS all other acoustic or air paths to prevent fire/
smoke spread and acoustic transmission.
M&E runs and other services to be
pre-planned to minimise or eliminate GTEC Dryliner Ceiling system may be used to
penetrations through rated ceilings. upgrade existing, retained ceilings provided
FINISHING
All board joints to be taped, jointed or
finished according to guidance in Finishing
section (p276-291) to achieve system
performances. Where ceiling is not intended
to be decorated GTEC Intumescent Acoustic
Sealant to be used to seal board joints.
LININGS
type to be used.
FIRE PROTECTION
FINISHING
REFERENCE
GTEC
DIRECT-TO-TIMBER
CEILING SYSTEMS
The GTEC Direct-to-Timber Ceiling system is the simplest method of
creating a flat ceiling surface for decoration and achieving excellent
fire performance.
WHERE TO USE:
The GTEC Direct to Timber system is used in both renovation
and new-build domestic applications.
FEATURES BENEFITS
Only requires board and screws Reduces installation time and costs
Can be used with GTEC Resilient Bar Improves acoustic performance and reliability
with some engineered joists
GTEC DIRECT-TO-TIMBER CEILING
163
INTRODUCTION
INTRODUCTION
PARTITIONS
Screw fix board to joist at
GTEC Intumescent
Acoustic Sealant
LININGS
cut ends
FIRE PROTECTION
BOARDS
All GTEC Boards See performance tables, p122-126
Provides wall surface suitable for finishing
FRAME
Timber frame Supplied by others
Structural frame forming part of an external
or internal wall
FIX
GTEC High Thread Screws (as appropriate) See screw selector, p334
For attaching plasterboard to timber
FINISHING
GTEC Joint Tape n/a
Joint reinforcement in conjunction with
GTEC Jointing Compounds
165
INTRODUCTION
INTRODUCTION
SYSTEM GUIDANCE
FRAME
FC-DT-101S-Perimeter detail FC-DT-102M-Timber ceiling with resilient bar
PARTITIONS
GTEC Board
to suit required performance
GTEC Board
GTEC Intumescent
to suit required performance
Acoustic Sealant
Engineered or square joists
SECTION ISOMETRIC
LININGS
of ceiling, around any obtrusions such as by overlapping at joists and fixing both
columns and between joists to provide board sections to joist.
fixing at bound board edges.
Pieces of Resilient Bar required to provide
Joists and noggings to have minimum bearing fixing of boards at perimeter of ceiling.
face of 44mm. Trusses to BS 5268-3 may
have bearing face of minimum 38mm.
FIRE PROTECTION
Inclusion of GTEC Resilient Bar is
recommended when fixing boards to
engineered joists to mitigate potential for
differential movement between substrate
and board.
INSULATION
Any insulation to be of type and thickness to
achieve performance and tightly installed in a
continuous layer between joists.
FINISHING
REFERENCE
BOARDING
FC-DT-201, 202 & 203P-Board Layout – single layer
GTEC Board
to suit required performance
SINGLE LAYER
Joists at 400/450 or
600mm centres
DOUBLE LAYER
Joists at 400/450 or
600mm centres
Noggings at 1200mm
centres to support edges
of second layer of boards
PLAN
GTEC DIRECT-TO-TIMBER CEILING
167
INTRODUCTION
INTRODUCTION
GTEC Direct-to-Timber Ceiling system is Board joints to be staggered between layers.
suitable for single, double and multiple layer
boarding. Any GTEC Fire Board, or other GTEC Type
F (BS EN 520) board, required by the
Select base layer(s) and finishing layer(s) system performance, to be installed as
GTEC Boards by consulting System the outermost/finishing layer.
Performance Tables (p133-p136) and Product
Specification (p294-307) to achieve required GTEC Resilient Bar option only:
PARTITIONS
performance. See High Performance Boards
GTEC Resilient Bar is suitable for single and
guide p12 for further selection information.
double layer boarding.
Boards to span across joists with bound
Boards to be mechanically fixed to GTEC
edges at right angles to joists.
Resilient Bar only at 150mm centres for cut
LININGS
FIRE PROTECTION
JUNCTIONS
FC-DT-501S-Junction of partition to ceiling
Abutting partitions to coincide with and fix to
joist install additional intermediate ‘pick-up’
joists/noggings as required.
coincide partition
with joist
Separate boards at partition head to reduce
sound transmission.
GTEC Intumescent
FINISHING
Acoustic Sealant
screw fix track
through to joist
SECTION
Services running through ceiling void to be Bead of GTEC Intumescent Acoustic Sealant
supported by structural soffit/joist and not to be applied to perimeter of all runs and in
GTEC Board. all other locations specified in Construction
Detail Drawings.
FINISHING
All board joints to be taped, jointed or finished
according to guidance in Finishing section
(p276-291) to achieve system performances.
Where ceiling is not intended to be decorated
GTEC Intumescent Acoustic Sealant to be
used to seal board joints.
GTEC ACOUSTIC
FLOOR SYSTEMS
Load bearing timber floors separating dwellings or other spaces have
limited sound reduction properties. The GTEC Acoustic Floor, ‘floating
floor’ system improves the acoustic performance of these floors with
minimal additional depth.
WHERE TO USE:
GTEC Acoustic Floors are used for domestic renovation and
conversion projects or new build.
FEATURES BENEFITS
171
INTRODUCTION
INTRODUCTION
PARTITIONS
FLOORS AND CEILINGS
Tongue and groove floor boards
LININGS
GTEC Board
to suit
required performance
FIRE PROTECTION
GTEC Resilient Bar
GTEC Board
to suit required performance
fixed to metal angle only
Insulation laid in
continuous layer
FINISHING
REFERENCE
BOARDS
All GTEC Boards See performance tables, p137
Provides wall surface suitable for finishing
FRAME
GTEC Acoustic Floor Clip RAFC25
Metal clips for connecting to wooden joists
FIX
GTEC Acoustic Floor Self Tapping Screws See screw selector, p334
For attaching plasterboard to metal angle
FINISHING
GTEC Joint Tape n/a
Joint reinforcement in conjunction with
GTEC Jointing Compounds
173
INTRODUCTION
INTRODUCTION
SYSTEM GUIDANCE
FRAME
FC-AF-101S-Perimeter detail
PARTITIONS
GTEC Metal Angle
GTEC Board
to suit required
performance
SECTION
GTEC Acoustic Floor Clips to be fixed to GTEC Metal Angle MFC2330 to be fitted into
joists at 400mm centres each side of joist. GTEC Acoustic Floor Clips Joists with short
Perimeter joists to be fitted with clips on leg into clip. Lengths of metal angle to have
open side. Joists to be minimum 38mm thick minimum number of joints with any joints
and structurally sound. located at clips.
LININGS
width allows and staggered where joist is underside of joists at maximum 450mm
too narrow. centres and fixed to each joist with suitable
GTEC High Thread Drywall Screws (see screw
GTEC Resilient Tape to be fitted along top of selector p334).
joist and any full depth noggings, over clips,
to isolate floorboards. GTEC Resilient Bar may be spliced by
overlapping at joists and fixing both
FIRE PROTECTION
GTEC Acoustic Floor Screws to be used to sections to joist.
fix floorboard through plasterboard to GTEC
Metal Angle. Pieces of Resilient Bar required to provide
fixing of board at perimeter of ceiling.
INSULATION
Insulation to be of type and thickness to
achieve performance and tightly installed
in a continuous layer between joists.
FINISHING
REFERENCE
BOARDING
FC-AF-201S-Assembly stages – 1 and 2
SECTION
FC-AF-202S-Retained ceiling
GTEC Intumescent
Acoustic Sealant
100mm insulation
quilt laid over
existing ceiling
Existing ceiling
100mm strips of
GTEC Fire Board
fixed to joists
SECTION
GTEC ACOUSTIC FLOOR
175
INTRODUCTION
INTRODUCTION
FC-AF-203P-Flooring layout
400mm
PARTITIONS
GTEC Board
to suit required
performance
400mm
GTEC Board
to suit required
performance
LININGS
FIRE PROTECTION
floorboards laid across joists
PLAN
SECTION
BOARDING continued
Boarding to underside of ceiling to follow Floorboards to be installed across joists
guidance in GTEC Direct-to-Timber section and fixed through GTEC Board to GTEC
p162-169. Metal Angle both sides of every joist
using appropriate GTEC Acoustic Floor
Where required by retained ceiling system Screws in pattern shown in Construction
configuration 100mm strips of 15mm Detail drawing. Free-floating floor is
GTEC Fire Board to be fitted along each created when angle is pulled out of
side of joists. Further 15mm GTEC Fire clips during fixing of floorboards and
Board to be installed to bridge from strip GTEC Board to GTEC Metal Angle.
to strip providing a continuous barrier
between joists. Floorboards to be in contact with
GTEC Resilient Tape only.
Select GTEC Board as required by system
performance cut 4mm shorter than space Floorboards to be 3mm clear of perimeter
between joists, to be temporarily secured wall and sealed with GTEC Acoustic
to GTEC Metal Angle only at approx. Intumescent Sealant.
600mm centres.
Softwood floorboards may require gluing
to a plywood base to prevent warping.
PARTITIONS
GTEC Lining systems offer a wide range of plasterboard lining
fixing systems to walls and roofs for most typical substrates.
LININGS
GTEC Lining Systems to Framed External Walls 187
GTEC Roof Lining Systems 188
GTEC Pregybel Independent Lining Systems 190
FIRE PROTECTION
GTEC Contour Linings 202
GTEC Shallow Wall Linings 208
GTEC Dryliner Linings 216
GTEC Independent Wall Linings 226
GTEC Pregybel Independent Linings 236
FINISHING
REFERENCE
i
180 GTEC LININGS – PERFORMANCE TABLES
181
INTRODUCTION
INTRODUCTION
Max Min U-Value Fire Perf. Acoustic
Height Thickness BS476-22 Perf.
BS EN Rw dB
1364-1 (Ctr where
(m) (mm) (W/m2k) (mins) applicable)
System Ref. Component
PARTITIONS
Facing Layer(s): – – 0.28 – –
1x 70mm GTEC Thermal K Board –
Lining: GTEC Dryliner Channel System
Insulation: –
Wall Leaf: 215mm concrete blockwork
(2300kg/m3)
Finish: 12mm sand/cement render
LININGS
Facing Layer(s): – - 0.29 – –
1x 12.5mm GTEC Vapour Board –
Lining: GTEC Dryliner Channel System
Insulation: 120mm glass fibre (BS 5250)
Wall Leaf: 215mm brickwork
Finish: –
FIRE PROTECTION
FINISHING
REFERENCE
183
INTRODUCTION
INTRODUCTION
Max Min U-Value Fire Perf. Acoustic
Height Thickness BS476-22 Perf.
BS EN Rw dB
1364-1 (Ctr where
(m) (mm) (W/m2k) (mins) applicable)
System Ref. Component
PARTITIONS
Facing Layer(s): – 325 – 30 63
1x 12.5mm GTEC dB Board Both sides – -15
Lining: GTEC Dryliner Channel System
Both sides
Insulation: 25mm glass mineral wool
16kg/m³ both sides
Wall Leaf: 2 x 100mm Solid Dense Block
LININGS
Facing Inner Layer(s): IS50Rx – 0.30 60 –
1x 12.5mm GTEC Fire V Board 2.7 Based on 60
Facing Outer Layer(s): IS60B IS70B stud
1x 12.5mm GTEC Fire or Megadeco Board 3.9
Lining: GTEC IS50Rx/IS60B/IS70B/IS90B IS70B
GTEC I Studs at 600mm centres 4.5
Insulation: 140mm glass fibre (BS 5250) IS90B
External Wall Leaf: 102mm brick or block 5.4
FIRE PROTECTION
work
185
INTRODUCTION
INTRODUCTION
Max Min U-Value Fire Perf. Acoustic
Height Thickness BS476-22 Perf.
BS EN Rw dB
1364-1 (Ctr where
(m) (mm) (W/m2k) (mins) applicable)
System Ref. Component
PARTITIONS
RdSAP Wall: Solid brick walls and cavity
walls 1996-2002
LININGS
Lining: GTEC Universal Bonding Compound
to form 10mm cavity
FIRE PROTECTION
Facing Inner Layer(s): – – 0.31 –– –
1x 22mm GTEC Thermal Board
187
INTRODUCTION
INTRODUCTION
GTEC LINING SYSTEMS TO FRAMED
EXTERNAL WALLS
Max Min U-Value Fire Perf. Acoustic
Height Thickness BS476-21 Perf.
BS EN Rw dB
1365-1 (Ctr where
(m) (mm) (W/m2k) (mins) applicable)
System Ref. Component
RFL 002
PARTITIONS
Facing Inner Layer(s): – 2.4 – 0.30 30 51
Facing Outer Layer(s): 30
1x 15mm GTEC Vapour Fire Board
Lining: Sheathing board – Recommended
Aqua Board
Insulation: 120mm glass fibre (BS5250)
Internal Wall Leaf: Timber Frame Stud
RFL 003
Facing Inner Layer(s): 2.4 – 0.29 60 53
1x 12.5mm GTEC Vapour Board 60
Facing Outer Layer(s):
1x 12.5mm GTEC Fire Board
Lining: Sheathing Board – Recommended
Aqua Board
Insulation: 120mm glass fibre (BS5250)
Internal Wall Leaf: Timber Frame Stud
work
External Wall Leaf: Brickwork
RFL 015
LININGS
Facing Inner Layer(s): – 2.4 – 0.29 30 60
Facing Outer Layer(s): 30 -5
1x 15mm GTEC Vapour Fire Board
Lining: Sheathing Board. Recommended
Aqua Board
Insulation: 120mm glass fibre (BS 5250)
Internal Wall Leaf: Timber Frame Stud
work with GTEC Resilient Bars at 400mm
FIRE PROTECTION
Centres
External Wall Leaf: Brickwork
RFL 016
Facing Inner Layer(s): 2.4 – 0.29 60 61
1x 12.5mm GTEC Vapour Fire Board 60 -4
Facing Outer Layer(s):
1x 12.5mm GTEC Fire Board
Lining: Sheathing Board. Recommended
Aqua Board
Insulation: 120mm glass fibre (BS5250)
Internal Wall Leaf: Timber Frame Stud
work with GTEC Resilient Bars at 600mm
Centres
External Wall Leaf: Brickwork
FINISHING
RFL 051
Facing Inner Layer(s): 4.2 – 0.34 60 59
1x 12.5mm GTEC Vapour Board 60
Facing Outer Layer(s):
1x 12.5mm GTEC Fire Board
Lining: 1 x 15mm Aqua Board
Insulation: 150mm glass fibre (BS 5250)
REFERENCE
within SFS
Internal Wall Leaf: 150mm SFS
External Wall Leaf: 100mm brick with
50mm cavity
RTC 031
Ceiling Inner Layer(s): – 11 30 0.15
Ceiling Outer Layer(s): 1x 12.5mm GTEC Fire Board 30
Accessories: –
Insulation: 100mm glass mineral wool between Trusses, 150mm over
Trusses, 10.5kg/m3
Structure: 47mm x 100mm Trusses at 400mm centres with noggings
RTC 032
Ceiling Inner Layer(s): 1x 12.5mm GTEC Fire V Board 12 60 0.15
Ceiling Outer Layer(s): 1x 12.5mm GTEC Fire Board 30
Accessories: –
Insulation: 100mm glass mineral wool between Trusses, 150mm over
Trusses, 10.5kg/m3
Structure: 47mm x 100mm Trusses at 600mm centres with noggings
189
INTRODUCTION
INTRODUCTION
Board Fire Perf. U-Value
Weight BS476-22 (W/m2k)
BS EN
1364-1
(kg/m2) (mins)
System Ref. Component
RTC 033
PARTITIONS
Ceiling Inner Layer(s): – 11 30 0.15
Ceiling Outer Layer(s): 1x 12.5mm GTEC Fire V Board 30
Accessories: –
Insulation: 100mm glass mineral wool between Trusses, 150mm over
Trusses, 10.5kg/m3
Structure: 38mm x 100mm Trusses at 600mm centres with noggings
LININGS
FIRE PROTECTION
FINISHING
REFERENCE
191
INTRODUCTION
INTRODUCTION
Max Weight Acoustic Absorption
Height Absorption co-efficient
Class, BS EN (aw), BS EN
ISO 11654 ISO 11654
(m) (kg/m2)
System Ref. Component
PARTITIONS
Ceiling Outer Layer(s): IS50Rx 2.7 12 C 0.70
1x GTEC Pregybel R15no1
Lining: GTEC IS50Rx/IS60B/IS70B/ IS60B 3.9
IS90B GTEC I Studs at 600mm
IS70B 4.5
centres
Insulation: 50mm glass mineral wool IS90B 5.4
and 300mm void
LININGS
PGL 302: Pregybel Lining – see p236
Ceiling Outer Layer(s): IS50Rx 2.7 12 D 0.50
1x GTEC Pregybel R15no8
Lining: GTEC IS50Rx/IS60B/IS70B/ IS60B 3.9
IS90B GTEC I Studs at 600mm
IS70B 4.5
centres
IS90B 5.4
FIRE PROTECTION
Insulation: 300mm void
Performance values are for imperforate, jointed systems using Siniat GTEC components (metal studs and tracks, boards, metal
accessories, screws and finishing systems) and specified insulation quilt material (type, thickness and density) and installed to
Siniat specification and installation guides.
All calculations are in accordance with Building Regulations: Conservation of fuel and power, Approved Document L: 2010.
WHERE TO USE:
GTEC Direct Bond Lining systems are used in new build residential
and general renovation projects.
FEATURES BENEFITS
Limited increase in wall thickness Minimal effect on room size and achieves the
required finish
Service cavity of 10-25mm can be created Allows installation of conduits and small services
Suitable for GTEC Thermal Boards One-fix method of achieving required thermal
performance
Bonds to the majority of masonry substrates Suits most construction projects and corrects
surface irregularities
GTEC DIRECT BOND LINING
193
INTRODUCTION
INTRODUCTION
PARTITIONS
FLOORS AND CEILINGS
non-laminated GTEC Board
to suit required performance
LININGS
FIRE PROTECTION
continuous dab around cut board to receive
socket boxes socket box
continuous dab
around socket boxes
cut board to
receive socket box
max. spacing
of 400mm
continuous bonding
compound ribbon 50mm
from base of board
GTEC DIRECT BOND LINING
195
INTRODUCTION
INTRODUCTION
SYSTEM COMPONENT TABLE
BOARDS
All GTEC Boards, except Aqua Board and See performance tables, p180-191
GTEC Vapour Board
Provides wall surface suitable for finishing.
PARTITIONS
All GTEC Thermal Boards See performance tables, p180-191
Provides wall surface suitable for finishing and thermal
insulation
FRAME
FIX
GTEC Universal Bonding Compound n/a
Directly bonds plasterboard to walls
FINISHING
GTEC Corner and Edge beads n/a
Corner and edge reinforcement
LININGS
Joint reinforcement in conjunction with
GTEC Jointing Compounds
FIRE PROTECTION
To finish joints between boards and bed corner beads
prior to decorating. Ensures system performance
SYSTEM GUIDANCE
SUBSTRATE
GTEC Direct Bond Lining system is suitable All loose plasterwork to be removed. Existing
for most level, masonry substrates. plasterwork in good condition may be
suitable for GTEC Direct Bonding provided
All substrates to be clean and dust free with all paint has been removed and adequate
all loose material removed. All grease, oil key is established by treating with a PVAC
and contaminants to be removed; chemical bonding agent according to manufacturer’s
cleaning may be required. instructions.
Substrate treatment for bonding: Substrates subject to moisture ingress to use
mechanical fixing system. External solid walls
Substrate Treatment with render finishes exposed to severe frosts
Very low suction May require mechanical fixing are not suitable for bonding.
Low and medium suction None
BONDING
LG-DB-180M-Dab sizing LG-DB-181S-Base detail
-75
50
25
GTEC Board
50 to suit required performance
GTEC Universal
Bonding Compound GTEC Intumescent Acoustic Sealant
ISOMETRIC SECTION
Continuous ribbon of
GTEC Universal
GTEC Thermal Board Bonding Compound
to suit required performance
SECTION SECTION
GTEC DIRECT BOND LINING
197
INTRODUCTION
INTRODUCTION
LG-DB-184S-Head detail – GTEC Thermal Boards
Continuous ribbon of
GTEC Universal
Bonding Compound
PARTITIONS
GTEC Thermal Board
to suit required performance
LININGS
Minimum 10mm thick and up to 25mm to
provide board levelling.
FIRE PROTECTION
300mm vertical centres for GTEC Thermal
Boards.
BOARDING
LG-DB-201E-Nailable plug arrangement
The GTEC Direct Bond lining system is
suitable for single layer boarding only.
ELEVATION
199
INTRODUCTION
INTRODUCTION
OPENINGS
LG-DB-401P-Window reveal LG-DB-402P-Door jamb
GTEC Board
to suit required
performance
PARTITIONS
Continuous ribbon of
GTEC Universal
Bonding Compound
PLAN PLAN
LININGS
Continuous ribbon of
GTEC Universal
Bonding Compound
FIRE PROTECTION
GTEC Flex Tape
Continuous ribbon of
Continuous ribbon of GTEC Universal
GTEC Universal Bonding Compound
Bonding Compound
PLAN PLAN
PLAN
Continuous ribbon of
GTEC Universal
Bonding Compound
Continuous ribbon of
GTEC Universal
Bonding Compound
GTEC Board
to suit required GTEC Thermal Board
performance to suit required
performance
10-25mm
PLAN PLAN
Continuous ribbon of
GTEC Universal
Bonding Compound
Continuous ribbon of
GTEC Universal
Bonding Compound Mineral wool insulation
to improve continuity
of thermal layer
GTEC Board
to suit required performance
PLAN PLAN
GTEC DIRECT BOND LINING
201
INTRODUCTION
INTRODUCTION
See Construction Details Drawings for further
guidance on arrangement and fixing.
FINISHING FIXTURES
PARTITIONS
All board joints to be taped, jointed All fixtures to be fixed through to substrate
or finished according to guidance in using appropriate fixings.
Finishing section (p276-291) to achieve
system performances.
SYSTEM CONTINUITY
GTEC Finish materials appropriate to board
M&E runs and other services to be GTEC Intumescent Acoustic Sealant to seal
pre-planned to minimise or eliminate all other acoustic or air paths to prevent fire/
penetrations through rated linings. smoke spread and acoustic transmission.
LININGS
FIRE PROTECTION
FINISHING
REFERENCE
GTEC CONTOUR
LINING SYSTEMS
The GTEC Contour Lining system is a simple and fast means
of renovating flat walls which simply need a new, consistently
smooth finish e.g. tiled or plastered walls which have become
scuffed or chipped.
WHERE TO USE:
GTEC Contour Board Lining system is suitable for use over
existing wall finishes such as distressed tiled walls.
FEATURES BENEFITS
203
INTRODUCTION
INTRODUCTION
PARTITIONS
FLOORS AND CEILINGS
GTEC Contour Board
LININGS
flat, smooth substrate requiring
refurbishment of surface only
FIRE PROTECTION
FINISHING
REFERENCE
BOARDS
All GTEC Boards, except Aqua Board and
GTEC Vapour Board
Provides wall surface suitable for finishing
FRAME
None required
FIX
GTEC Wall Lining Adhesive n/a
Ready mixed adhesive for direct bonding to substrate
FINISHING
GTEC Corner and Edge beads n/a
Corner and edge reinforcement
205
INTRODUCTION
INTRODUCTION
SYSTEM GUIDANCE
SUBSTRATE
GTEC Contour Lining system is suitable for Substrate treatment for bonding:
most flat, level, secure substrates not subject
to moisture ingress which require only
surface renovation. Substrate Treatment
PARTITIONS
High suction n/a
removed from ceramic tiles.
LININGS
vertical centres.
FIRE PROTECTION
FINISHING
REFERENCE
BOARDING
LG-CN-201E-Nailable plug arrangement
25mm
600mm
1600mm
1200mm
800mm
ELEVATION
i
208 GTEC SHALLOW WALL LINING
GTEC SHALLOW
WALL LINING
SYSTEMS
The GTEC Shallow Wall Lining system is an alternative to the
GTEC Direct Bond Lining system. It provides a mechanical fix for
boards which are unsuitable for use with GTEC Universal Bonding
Compound. It can also create a fully mechanically fixed option where
the substrate cannot be bonded, such as some concrete walls.
WHERE TO USE:
The GTEC Shallow Wall Lining system is suitable for most project
types and masonry substrates.
FEATURES BENEFITS
Intermittent cavity up to 25mm deep Space for small conduits and services
209
INTRODUCTION
INTRODUCTION
PARTITIONS
Aqua Board or Vapour Board or
other to suit required performance
LININGS
FIRE PROTECTION
BOARDS
All GTEC Boards See performance tables, p180-191
Provides wall surface suitable for finishing
in minimum thickness
FRAME
GTEC Shallow Wall Channel MFCS/RX
Dabbed or fixed to wall to provide fixing substrate
for boards
FIX
GTEC Universal Bonding Compound n/a
Gypsum based compound for bonding GTEC Shallow
Wall Channel to walls. Suitable for GTEC thermal boards
FINISHING
GTEC Corner and Edge beads n/a
Corner and edge reinforcement
211
INTRODUCTION
INTRODUCTION
SYSTEM GUIDANCE
SUBSTRATE
GTEC Shallow Wall Lining system is suitable All loose plasterwork to be removed.
for most level, masonry substrates and may Existing plasterwork in good condition may
be bonded or mechanically fixed. be suitable for GTEC Universal Bonding
Compound provided all paint has been
All substrates to be clean and dust free removed and key is established by treating
with all loose material removed. All grease, with a PVAC bonding agent according to
oil and contaminants to be removed; manufacturer’s instructions.
chemical cleaning may be required.
PARTITIONS
Substrates subject to moisture ingress
Substrate treatment for bonding: require mechanical fixing of GTEC Shallow
Wall Channels. External solid walls with
Substrate Treatment render finishes exposed to severe frosts
are not suitable for bonding.
Very low suction May require mechanical fixing
FRAME
LG-ML-101S-Head Detail LG-ML-102S-Base Detail
GTEC Intumescent
Acoustic Sealant
GTEC Board
to suit required
GTEC Universal performance
Bonding Compound
GTEC Universal
screw fix plasterboard Bonding Compound
to channel at 300mm centres
LININGS
screw fix plasterboard
to channel at 300mm centres
GTEC Shallow
Wall Channel GTEC Shallow
80mm
Wall Channel
Max.
GTEC Intumescent
Acoustic Sealant
GTEC Board
to suit required
FIRE PROTECTION
performance
SECTION SECTION
-75
50
25
GTEC Shallow Wall Channel
mechanically fixed to substrate
50
FINISHING
0
25
board fixed to channel
GTEC Universal at max. 300mm centres
REFERENCE
Bonding Compound
ISOMETRIC ISOMETRIC
FRAME continued
GTEC Shallow Wall Channel to be fixed to Bonding dabs to be:
substrate in continuous vertical lengths
at 600mm horizontal centres using dabs 250mm x 50-75mm.
of GTEC Universal Bonding Compound or
Minimum 10mm thick and up to 25mm
mechanically fixed using appropriate fixings
to provide board levelling.
by others.
At 450mm maximum vertical centres.
GTEC Shallow Wall Channels may be shot
fired to dense substrates following fixing Minimum of two dabs per channel not
manufacturer’s instructions. exceeding vertical centres above.
Horizontal lengths of GTEC Shallow Wall Minimum 25mm from board edges.
Channel to be fixed maximum 50mm from
head and base of lining. Continuous ribbons of bonding
compound to be provided 50mm from
head and base of board and around
perimeter of walls and openings to
provide fixing for horizontal channel.
BOARDING
The GTEC Shallow Wall lining system is Height of GTEC Shallow Wall linings should
suitable for single layer boarding only. not exceed two boards in height in one
operation. Safety precautions should be
Select base layer(s) and finishing layer(s) taken when bonding boards above single
GTEC Boards by consulting System board height.
Performance Tables, p180-191, and Product
Specification, p294-307, to achieve required Thermal Boards only:
performance. See High Performance Boards
guide p12 for further selection information. Select GTEC Thermal Board type and
thickness according to desired thermal value
Boards to be 5mm less than floor to and requirement for vapour barrier.
ceiling height.
GTEC Thermal Board thickness may be
Board edges to be centred over channels. reduced by utilising higher insulation grade
boards, e.g. GTEC Thermal K Board.
Boards to be mechanically fixed to channels
at 300mm centres using appropriate GTEC
Drywall Screws. See screw selector p334.
GTEC SHALLOW WALL LINING
213
INTRODUCTION
INTRODUCTION
MOVEMENT CONTROL JOINTS
LG-ML-301P-Movement joint
Max. Max.
GTEC Universal GTEC Shallow
80mm 80mm
Bonding Compound Wall Channel
PARTITIONS
FLOORS AND CEILINGS
GTEC Board
GTEC Movement
to suit required
Control Joint
performance
10mm
PLAN
Form movement control joints at maximum Fix GTEC Movement Control Joint, butted
10m intervals in the lining run. end-to-end, to board with sheradised or
galvanised staples.
Form movement control joints where the
lining crosses a structural movement joint.
LININGS
FIRE PROTECTION
OPENINGS AND CORNERS
LG-ML-401P-Window reveal LG-ML-402P-Door jamb
GTEC Board
to suit required
performance
GTEC Universal
GTEC Board Bonding Compound
FINISHING
to suit required
performance
GTEC Universal
Bonding Compound
GTEC Shallow
GTEC Corner 90º External / Wall Channel
GTEC Flex Tape
REFERENCE
GTEC Shallow
Wall Channel
PLAN PLAN
GTEC Universal
GTEC Universal
Bonding Compound
Bonding Compound
GTEC Shallow
Wall Channel
GTEC Shallow
Wall Channel
GTEC Board
GTEC Board to suit required
to suit required performance
performance
PLAN PLAN
GTEC Intumescent
Max.
Acoustic Sealant
80mm
Max.
GTEC Board
to suit required performance
PLAN
215
INTRODUCTION
INTRODUCTION
FINISHING FIXTURES
All board joints to be taped, jointed All fixtures to be fixed through to substrate
or finished according to guidance using appropriate fixings.
in Finishing section (p276-291) to achieve
system performances.
SYSTEM CONTINUITY
GTEC Finish materials appropriate to board
type to be used Bead of GTEC Intumescent Acoustic Sealant
to be applied to perimeter of all runs and in
PARTITIONS
all other locations specified in Construction
PENETRATIONS Detail Drawings.
M&E runs and other services to be GTEC Intumescent Acoustic Sealant to seal
pre-planned to minimise or eliminate all other acoustic or air paths to prevent fire/
penetrations through rated linings. smoke spread and acoustic transmission.
LININGS
FIRE PROTECTION
FINISHING
REFERENCE
GTEC DRYLINER
LINING SYSTEMS
The GTEC Dryliner Lining system is a fully dry, light frame,
drylining system. The cavity created behind the boards allows
for heavier services and sound or thermal insulation.
For stable, high performance drylining, the system uses GTEC Dryliner
Brackets fixed to the substrate to support a frame of GTEC Dryliner
Channel and Tracks.
WHERE TO USE:
The GTEC Dryliner Lining system is ideal for most stable
substrates where continuous cavities behind boards of up
to 130mm are required and/or where high levels of substrate
correction are needed.
FEATURES BENEFITS
Cavity up to 130mm deep Space for heavy duty services and insulation
217
INTRODUCTION
INTRODUCTION
PARTITIONS
GTEC Dryliner Track
mm
600
x.
Ma
LININGS
Max. 800mm
FIRE PROTECTION
GTEC Board
to suit required
performance
GTEC Intumescent
Acoustic Sealant
FINISHING
REFERENCE
BOARDS
All GTEC Boards See performance tables, p180-191
Provides ceiling surface suitable for finishing
FRAME
GTEC Dryliner Channel RD1
A galvanised steel furring channel for
plasterboard fixing
INSULATION
Mineral wool insulation See performance tables
Increases fire and acoustic insulation performance supplied by others
FIX
GTEC Drywall Screws (as appropriate) See screw selector, p334
For connecting plasterboard and metal components
GTEC DRYLINER LINING
219
INTRODUCTION
INTRODUCTION
System Component System primary use Product Reference
FINISHING
GTEC Corner and Edge beads n/a
Corner and edge reinforcement
PARTITIONS
Joint reinforcement in conjunction with
GTEC Jointing Compounds
LININGS
FIRE PROTECTION
SYSTEM GUIDANCE
SUBSTRATE
GTEC Dryliner Lining system is suitable GTEC Independent Wall Lining system to be
for most stable substrates where fixing of used for substrates subject to uncontrolled
bracket will be structurally secure. moisture ingress.
FRAME
LG-DY-002P-Cavity size range LG-DY-102S-Head detail – GTEC Thermal Boards
GTEC Intumescent
Acoustic Sealant
Max. 800mm
Dryliner Bracket to channel at 300mm centres
GTEC Intumescent
Acoustic Sealant
SECTION SECTION
GTEC Board
to suit required performance screw fix plasterboard
to channel at 300mm centres
SECTION SECTION
GTEC DRYLINER LINING
221
INTRODUCTION
INTRODUCTION
GTEC Dryliner Track to be fixed to structure GTEC Dryliner Brackets to fixed to structure
at perimeter of lining run. Fix at 600mm in a line at maximum 800mm vertical centres
centres using appropriate fixings. Allow for to receive GTEC Dryliner Channel:
board depth when positioning channel and
to achieve required cavity depth. GTEC SR and XR Brackets to be fixed
using appropriate structural fixing
Select GTEC Dryliner Brackets (SR and XR) supplied by others.
PARTITIONS
to suit cavity depth required:
GTEC Dryliner Channel to be 5mm shorter
GTEC Dryliner Bracket Cavity Depth Range than floor to ceiling height, located into
GTEC Dryliner Track.
GTEC SR Bracket 25mm-60mm
INSULATION
Any insulation to be of type and thickness Where insulation may be expected to slump
to achieve performance and tightly installed suspend from GTEC Insulation Hold strips
in a continuous layer between brackets and 150mm from top of partition and at 1200mm
behind channels. vertical centres.
LININGS
10mm clear gap to be maintained between
substrate and insulation.
BOARDING
FIRE PROTECTION
The GTEC Dryliner lining system is suitable for Over-height single layer boarding:
single, double and multiple layer boarding.
Where partition height exceeds board height
Select base layer(s) and finishing layer(s) fix boards to continuous band of GTEC Flat
GTEC Boards by consulting System Strap FS90/W or GTEC MFIX behind all
Performance Tables, p180-191, and Product horizontal joints to maintain fire integrity.
Specification, p294-307, to achieve required
performance. See High Performance Boards Over-height multiple layer boarding only:
guide p12 for further selection information.
Where partition height exceeds board
Boards to be 5mm less than floor to height for double or multiple layer boarding
ceiling height. fix outer layer of boards to continuous
band of GTEC Flat Strap FS50/RX behind
FINISHING
10mm 10mm
PLAN PLAN
Form movement control joints at maximum Fix GTEC Movement Control Joint, butted
10m intervals in the lining run. end-to-end, to board with sheradised or
galvanised staples.
Form movement control joints where the
lining crosses a structural movement joint.
PLAN PLAN
GTEC DRYLINER LINING
223
INTRODUCTION
INTRODUCTION
LG-DY-501P-Internal Corner LG-DY-502P-Internal corner – GTEC Thermal Boards
PARTITIONS
GTEC Intumescent Acoustic Sealant
GTEC Intumescent Acoustic Sealant
fold bracket over channel
and fix to suit corners fold bracket over channel
and fix to suit corners
GTEC Dryliner Channel
GTEC Dryliner Channel
PLAN PLAN
50mm 25mm
LININGS
fixed to the track
GTEC Dryliner Channel
FIRE PROTECTION
performance GTEC Board
to suit required
performance
PLAN PLAN
GTEC Intumescent
Acoustic Sealant
GTEC Intumescent
Acoustic Sealant
PLAN PLAN
GTEC Dryliner
Channel
SECTION
FINISHING FIXTURES
All board joints to be taped, jointed Fixtures may be fixed through to substrate
or finished according to guidance in using appropriate fixings or fixed through
Finishing section (p276-291) to achieve board to channels.
system performances.
Fixtures may be attached directly to board
GTEC Finish materials appropriate to provided adequate provision has been made.
board type to be used. See guidance in GTEC C Stud Partitions
section, p67.
PENETRATIONS
M&E runs and other services to be
SYSTEM CONTINUITY
pre-planned to minimise or eliminate Bead of GTEC Intumescent Acoustic Sealant
penetrations through rated linings. to be applied to perimeter of all runs and in
all other locations specified in Construction
Any penetrations must be fully sealed with Detail Drawings.
GTEC Intumescent Acoustic Sealant or
other fire resisting material as specified GTEC Intumescent Acoustic Sealant to seal
in Construction Detail Drawings. all other acoustic or air paths to prevent fire/
smoke spread and acoustic transmission.
Protect all electrical cables
in cavity with conduit. Full, imperforate system continuity to be
maintained to achieve rated performances.
GTEC INDEPENDENT
WALL LINING
SYSTEMS
Based on the GTEC C Stud Partition system, the GTEC Independent
Wall Lining system is a fully dry, light frame, drylining system. It is
completely separated from the underlying substrate.
WHERE TO USE:
Ideal for commercial projects where deep continuous cavities behind boards
are needed to correct or isolate substrates and accommodate services.
Particularly suited to substrates which may not be suitable for direct fixing,
e.g. metal cladding and other modern methods of construction.
FEATURES BENEFITS
Completely variable cavity depth Provides space for heavy duty services
and the highest levels of insulation
227
INTRODUCTION
INTRODUCTION
PARTITIONS
GTEC C Studs
fixed at right angles
GTEC I Stud
BOARDS
All GTEC Boards See performance tables, p180-191
Provides wall surface suitable for finishing
FRAME
GTEC I Studs IS50/RX, IS60/B, IS70/B, IS90/B
Metal profile for vertical frame elements
INSULATION
Mineral wool insulation See performance table
Increases fire and acoustic insulation performance supplied by others
FIX
GTEC Drywall Screws (as appropriate) See screw selector, p334
For connecting plasterboard and metal components
GTEC INDEPENDENT WALL LINING
229
INTRODUCTION
INTRODUCTION
System Component System primary use Product Reference
FINISHING
GTEC Corner and Edge beads n/a
Corner and edge reinforcement
PARTITIONS
Joint reinforcement in conjunction with
GTEC Jointing Compounds
LININGS
FIRE PROTECTION
SYSTEM GUIDANCE
SUBSTRATE
GTEC Independent Wall Lining system Protrusions greater than design
is fully independent of the substrate. cavity depth to be removed.
FINISHING
REFERENCE
FRAME
LG-IW-101S-Head detail LG-IW-102S-Base detail
GTEC Intumescent
Acoustic Sealant
GTEC Board
GTEC Board to suit required performance
to suit required
performance
Select compatible sized (e.g. 50mm stud Protect base track from moisture with damp
and 52mm track) GTEC I Stud, GTEC C Stud proof membrane when situated on newly laid
and GTEC U Track framing elements to suit concrete floors.
system performance.
All GTEC Studs to be 5mm shorter than floor
GTEC U Track Deep or Extra Deep Flange to to ceiling height except in case of deflection
be used for heights greater than 4.2m. requirement.
GTEC C Studs as starter studs to be fixed Intermediate GTEC Studs to be friction fitted
with web flat to structure using appropriate to allow for adjustment during boarding.
fixings at maximum 600mm centres and
fixed to head and track with appropriate GTEC Studs to be at centres required to
GTEC Drywall Screws (see screw selector achieve performance and at a maximum
p334). of 600mm centres.
GTEC U Track to be fixed flat to structure For heights over values in performance tables
using appropriate fixings at maximum GTEC Acoustic V Brace 90 may be used to
600mm centres and positioned a minimum brace linings while maintaining acoustic
of 10mm from substrate. isolation. Contact Technical Services for more
information.
Timber sole plate may be required on uneven
floors or where lining is constructed prior to
screeding.
GTEC INDEPENDENT WALL LINING
231
INTRODUCTION
INTRODUCTION
INSULATION
Any insulation to be of type and thickness Where insulation may be expected to slump
to achieve performance and installed in a suspend from GTEC Insulation Hold strips
continuous layer between and behind studs fixed across studs, 150mm from top of
to suit required performance. partition and at 1200mm vertical centres.
PARTITIONS
FLOORS AND CEILINGS
BOARDING
GTEC Independent Lining system is suitable Over-height single layer boarding only:
for single, double and multiple layer boarding.
Where partition height exceeds board height
Select base layer(s) and finishing layer(s) fix boards to continuous band of GTEC Flat
GTEC Boards by consulting System Strap FS90/W or GTEC MFIX behind all
Performance Tables, p180-191, and Product horizontal joints to maintain fire integrity.
Specification, p294-307, to achieve required
performance. See High Performance Boards Over-height multiple layer boarding only:
guide p12 for further selection information.
Where partition height exceeds board
LININGS
Boards to be 5mm less than floor to ceiling height for double or multiple layer
height. boarding fix outer layer of boards to
continuous band of GTEC Flat Strap
Strips of board 300mm wide or less to be FS50/RX behind all horizontal joints.
avoided by stud location rearrangement.
Thermal Boards only:
Boards to be mechanically fixed to studs
FIRE PROTECTION
at 300mm centres using appropriate GTEC Select GTEC Thermal Board type and
Drywall Screws. See screw selector p334. thickness according to desired thermal
value and requirement for vapour barrier.
Base layers of boarding may be temporarily
fixed at 600mm centres providing final layer GTEC Thermal Board thickness may be
is fixed through to stud at 300mm centres reduced by utilising higher insulation
grade boards, e.g. GTEC Thermal K Board.
Board edges to be centred over studs.
Max. Max.
50mm 50mm
rock mineral
wool insulation
GTEC I Stud
GTEC Board
to suit required
performance
10mm GTEC Movement
Control Joint
PLAN
Form movement control joints at maximum Fix GTEC Movement Control Joint, butted
10m intervals in the partition run. end-to-end, to board with sheradised or
galvanised staples.
Form movement control joints where the
partition crosses a structural movement joint.
OPENINGS
LG-IW-401P-Window reveal
Sections of GTEC C Studs to be fitted to back
of jamb C Stud above and below opening.
PLAN
GTEC INDEPENDENT WALL LINING
233
INTRODUCTION
INTRODUCTION
CORNERS AND JUNCTIONS
LG-IW-501P-Internal Corner LG-IW-502P-External Corner
GTEC Intumescent
Acoustic Sealant
PARTITIONS
600mm centres
GTEC Board
screw fix GTEC C Stud together to suit required
through board at 600mm centres performance
GTEC Intumescent
Acoustic Sealant
GTEC Board
to suit required performance
PLAN PLAN
GTEC Board
GTEC Board to suit required performance
to suit required performance
LININGS
Screw fix GTEC C Stud to
GTEC I Stud at 600mm centres
FIRE PROTECTION
GTEC Intumescent
Acoustic Sealant
PLAN
PLAN PLAN
at 3m vertical centres
See Construction Details Drawings for further
guidance on arrangement and fixing.
GTEC C Stud
fixed to brace
REFERENCE
PLAN
PENETRATIONS FINISHING
M&E runs and other services to be All board joints to be taped, jointed
pre-planned to minimise or eliminate or finished according to guidance in
penetrations through rated partitions. Finishing section (p276-291) to achieve
system performances.
Any penetrations must be fully sealed
with GTEC Intumescent Acoustic Sealant GTEC Finish materials appropriate to board
or other fire resisting material as specified type to be used.
in Construction Detail Drawings.
ABERDEEN SPORTS
VILLAGE AQUATICS CENTRE
ABERDEEN, SCOTLAND
Sector: Leisure
FINISHING
i
236
GTEC PREGYBEL INDEPENDENT LINING
GTEC PREGYBEL
INDEPENDENT
LINING SYSTEMS
Sound absorbing wall linings can be created using the GTEC Pregybel
Independent Lining system to improve acoustic comfort by reducing
sound reflection in larger spaces.
WHERE TO USE:
GTEC Pregybel Independent Linings are used in commercial
applications to improve the acoustic conditions in large spaces.
FEATURES BENEFITS
Variable cavity depth Cavity size can be optimised for service and
insulation requirements
Utilises GTEC Independent Wall Lining framing One set of components on site.
Easy to install.
INTRODUCTION
INTRODUCTION
PARTITIONS
GTEC U Track
GTEC I Studs
LININGS
GTEC Pregybel Board
to suit required performance
FIRE PROTECTION
GTEC Board
to suit required performance
BOARDS
GTEC Pregybel Boards See performance tables, p180-191
Perforated board for acoustic absorption
FRAME
GTEC I Studs IS50/RX, IS60/B, IS70/B, IS90/B
Metal profile for vertical frame elements
INSULATION
Mineral wool insulation See performance table
Increases fire and acoustic insulation performance supplied by others
FIX
GTEC Drywall Screws (as appropriate) See screw selector, p334
For connecting plasterboard and metal components
239
GTEC PREGYBEL INDEPENDENT LINING
INTRODUCTION
INTRODUCTION
System Component System primary use Product Reference
FINISHING
GTEC Corner and Edge beads n/a
Corner and edge reinforcement
PARTITIONS
Joint reinforcement in conjunction with
GTEC Jointing Compounds
LININGS
SYSTEM GUIDANCE
See guidance in GTEC Independent Wall Lining section and additional
FIRE PROTECTION
considerations given below:
BOARDING
LG-PG-101S-Head detail LG-PG-102S-Base detail
Min.
10mm
GTEC Intumescent screw fix plasterboard
Acoustic Sealant to stud at 300mm centres
to suit required
performance
GTEC I Stud cut 5mm shorter
GTEC I Stud 5mm shorter than floor to ceiling height
than floor to ceiling height
GTEC U Track Deep Flange
fixed at 600mm centres
Min.
10mm GTEC Intumescent
screw fix plasterboard Acoustic Sealant
REFERENCE
SECTION SECTION
BOARDING continued
LG-PG-501P-Internal Corner LG-PG-502P-External Corner
GTEC Intumescent
Acoustic Sealant
PLAN PLAN
INTRODUCTION
INTRODUCTION
ACOUSTIC PANEL
LG-PG-002M-Pregybel Acoustic Panel LG-PG-103E-Acoustic Panel frame options
PARTITIONS
to suit required performance GTEC UDT70/B Tracks
Max. 3 metres
GTEC Board
Fix to wall with
appropriate fixing
GTEC Metal by others
Angle
(MFC2550)
GTEC Flat
Strap to
brace frame GTEC MFC2550 Angle
Max. 500mm
Stud and
Track Frame
Max. 3 metres
GTEC CS70/B Studs
LININGS
Insulation quilt and
void to suit required
Fix to wall with
performance
appropriate fixing
GTEC Metal Angle by others
(MFC2550)
FIRE PROTECTION
GTEC MFC2550 Angle
Max. 500mm
ISOMETRIC SECTION
GTEC Acoustic Panels are suitable for fixing Board and insulation configuration to be
to most, level, stable and secure substrates selected according to acoustic absorption
and should be fixed with appropriate fixings and pattern required, see performance tables
capable of supporting the load of the panel. p180-191.
PARTITIONS
PROTECTION
Performance Tables
GTEC Shaftwall systems 244
LININGS
GTEC Shaftwall Stairwell systems 248
GTEC Horizontal Shaftwall systems 249
GTEC Encasement systems 250
FIRE PROTECTION
GTEC Shaftwall systems 254
GTEC Encasement systems 268
FINISHING
REFERENCE
Note: During 2017, 25mm Fire Core Board products will be replaced with 19mm
Fire Core Board. The Drywall Manual will be updated during the year to reflect
these changes. For further information please contact Technical Services.
i
244 GTEC FIRE PROTECTION – PERFORMANCE TABLES
RCS 102
Facing: 1x 15mm GTEC Fire or 35 4.2 2x 78 60 Severe 39
Megadeco Board ES60B 30
Studs: GTEC CHS60B CH-Studs at 4.5
600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: –
Insulation: –
RCS 106
Facing: 1x 15mm GTEC Fire or 36 4.2 2x 78 60 Severe 45
Megadeco Board ES60B 60
Studs: GTEC CHS60B CH-Studs at 4.5
600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: –
Insulation: 25mm 16kg/m3 glass
mineral wool
RCS 203
Facing: 1x 15mm GTEC Fire or 36 6.0 2x 107 60 Severe 43
Megadeco Board ES90B 30
Studs: GTEC CHS90B CH-Studs at 6.4
600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: –
Insulation: –
RCS 208
Facing: 1x 15mm GTEC Fire or 37 6.0 2x 107 60 Severe 51
Megadeco Board ES90B 60
Studs: GTEC CHS90B CH-Studs at 6.4
600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: –
Insulation: 25mm 16kg/m3 glass
mineral wool
RCS 310
Facing: 1x 15mm GTEC Fire or 38 6.8 2x 161 60 Severe 43
Megadeco Board ES146B 60
Studs: GTEC CHS146B CH-Studs 8.0
at 600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: –
Insulation: –
RCS 311
Facing: 1x 15mm GTEC Fire or 38 6.8 2x 161 60 Severe 51
Megadeco Board ES146B 60
Studs: GTEC CHS146B CH-Studs 8.0
at 600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: –
Insulation: 25mm 16kg/m3 glass
mineral wool
245
INTRODUCTION
INTRODUCTION
System Max Max Height Nominal Fire Perf. Strength Acoustic
Weight Height Back-to- Thickness BS476-22 Duty Perf.
Back GTEC E BS EN Rating to Rw dB
Studs 1364-1 BS 5234 (Ctr where
(kg/m2) (m) (m) (mm) (mins) applicable)
System Ref. Component
RCS 103
PARTITIONS
Facing Inner Layer(s): 42 4.4 2x 88 90 Severe 40
1x 12.5mm GTEC Fire Board ES60B 90
Facing Outer Layer(s): 1x 12.5mm 4.7
GTEC Fire or Megadeco Board
Studs: GTEC CHS60B CH-Studs at
600mm centres
Core: 1x 25mm GTEC Fire Core Board
RCS 104
Facing Inner Layer(s): 43 4.4 2x 88 90 Severe 46
1x 12.5mm GTEC Fire Board ES60B 90
Facing Outer Layer(s): 1x 12.5mm 4.7
GTEC Fire or Megadeco Board
Studs: GTEC CHS60B CH-Studs at
600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: –
Insulation: 25mm 16kg/m3 glass
mineral wool
RCS 205
Facing Inner Layer(s): 43 6.4 2x 118 90 Severe 45
LININGS
1x 12.5mm GTEC Fire Board ES90B 90
Facing Outer Layer(s): 1x 12.5mm 6.8
GTEC Fire or Megadeco Board
Studs: GTEC CHS90B CH-Studs at
600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: –
Insulation: –
FIRE PROTECTION
RCS 207
Facing Inner Layer(s): 44 6.4 2x 118 90 Severe 52
1x 12.5mm GTEC Fire Board ES90B 90
Facing Outer Layer(s): 1x 12.5mm 6.8
GTEC Fire or Megadeco Board
Studs: GTEC CHS90B CH-Studs at
600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: –
Insulation: 25mm 16kg/m3 glass
mineral wool
RCS 301
FINISHING
RCS 302
Facing Inner Layer(s): 47 7.5 2x 175 90 Severe 52
1x 12.5mm GTEC Fire Board ES146B 90
Facing Outer Layer(s): 1x 12.5mm 8.2
GTEC Fire or Megadeco Board
Studs: GTEC CHS146B CH-Studs
at 600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: –
Insulation: 25mm 16kg/m3 glass
mineral wool
RCS 109
Facing Inner Layer(s): 45 4.8 2x 95 120 Severe 41
1x 15mm GTEC Fire Board ES60B 90
Facing Outer Layer(s): 1x 15mm 5.1
GTEC Fire or Megadeco Board
Studs: GTEC CHS60B CH-Studs at
600mm centres
Core: 1x 25mm GTEC Fire Core
Board
Core Facing: –
Insulation: –
RCS 110
Facing Inner Layer(s): 46 4.8 2x 95 120 Severe 47
1x 15mm GTEC Fire Board ES60B 90
Facing Outer Layer(s): 1x 15mm 5.1
GTEC Fire or Megadeco Board
Studs: GTEC CHS60B CH-Studs at
600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: –
Insulation: 25mm 16kg/m3 glass
mineral wool
RCS 206
Facing Inner Layer(s): 47 6.7 2x 120 120 Severe 47
1x 15mm GTEC Fire Board ES90B 90
Facing Outer Layer(s): 1x 15mm 7.1
GTEC Fire or Megadeco Board
Studs: GTEC CHS90B CH-Studs at
600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: –
Insulation: –
RCS 210
Facing Inner Layer(s): 48 6.7 2x 120 120 Severe 54
1x 15mm GTEC Fire Board ES90B 90
Facing Outer Layer(s): 1x 15mm 7.1
GTEC Fire or Megadeco Board
Studs: GTEC CHS90B CH-Studs at
600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: –
Insulation: 25mm 16kg/m3 glass
mineral wool
247
INTRODUCTION
INTRODUCTION
System Max Max Height Nominal Fire Perf. Strength Acoustic
Weight Height Back-to- Thickness BS476-22 Duty Perf.
Back GTEC E BS EN Rating to Rw dB
Studs 1364-1 BS 5234 (Ctr where
(kg/m2) (m) (m) (mm) (mins) applicable)
System Ref. Component
RCS 303
PARTITIONS
Facing Inner Layer(s): 51 8.0 2x 180 120 Severe 51
1x 15mm GTEC Fire Board ES146B 90
Facing Outer Layer(s): 1x 15mm 9.2
GTEC Fire or Megadeco Board
Studs: GTEC CHS146B CH-Studs
at 600mm centres
Core: 1x 25mm GTEC Fire Core
RCS 304
Facing Inner Layer(s): 52 8.0 2x 180 120 Severe 54
1x 15mm GTEC Fire Board ES146B 90
Facing Outer Layer(s): 1x 15mm 9.2
GTEC Fire or Megadeco Board
Studs: GTEC CHS146B CH-Studs
at 600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: –
Insulation: 25mm 16kg/m3 glass
mineral wool
LININGS
FIRE PROTECTION
FINISHING
REFERENCE
RCS 503
Facing: 1x 12.5mm GTEC Fire or 42 4.5 – 88 120 Severe 40
Megadeco Board – 90
Studs: GTEC CHS60B CH-Studs at
600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: 1x 12.5mm GTEC Fire
or Megadeco Board
Insulation: –
RCS 504
Facing: 1x 12.5mm GTEC Fire or 43 4.5 – 88 120 Severe 44
Megadeco Board – 90
Studs: GTEC CHS60B CH-Studs at
600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: 1x 12.5mm GTEC Fire
or Megadeco Board
Insulation: 25mm 16kg/m3 glass
mineral wool
RCS 505
Facing Inner Layer(s): 54 5.4 – 101 120 Severe 43
1x 12.5mm GTEC Fire Board – 120
Facing Outer Layer(s): 1x 12.5mm
GTEC Fire or Megadeco Board
Studs: GTEC CHS60B CH-Studs at
600mm centres
Core: 1x 25mm GTEC Fire Core Board
Core Facing: 1x 12.5mm GTEC Fire
or Megadeco Board
Insulation: –
249
INTRODUCTION
INTRODUCTION
GTEC HORIZONTAL SHAFTWALL SYSTEMS
See p267 for guidance
System Max Max Span Nominal Fire Perf. Strength Acoustic
Weight Span Back-to- Thickness BS476-22 Duty Perf.
Back GTEC E BS EN Rating to Rw dB
Studs 1364-2 BS 5234 (Ctr where
(kg/m2) (m) (m) (mm) (mins) applicable)
System Ref. Component
PARTITIONS
Facing Inner Layer(s): 47 3.0 – 123 60 60 47
1x 15mm GTEC Fire Board – 60
Facing Outer Layer(s): 1x 15mm
GTEC Fire or Megadeco Board
Studs: GTEC CHS90B CH-Studs at
600mm centres
Core: 1x 25mm GTEC Fire Core Board
LININGS
FIRE PROTECTION
FINISHING
REFERENCE
RCE 001
Facing: 1x 12.5mm GTEC Fire or Megadeco Board
Framing: GTEC Edge Channel & CB Clips at 600mm Centres
Fire resistance columns: 30 Mins up to 280 Hp/A factor
60 Mins up to 280 Hp/A Factor
Fire resistance beams: 30 Minutes up to 280 Hp/A factor
60 Minutes up to 115 Hp/A Factor
RCE 002
Facing: 1x 15mm GTEC Fire or Megadeco Board
Framing: GTEC Edge Channel & CB Clips at 600mm Centres
Fire resistance columns: 90 Mins up to 115 Hp/A factor
Fire resistance beams: 60 Minutes up to 280 Hp/A factor
90 Minutes up to 50 Hp/A Factor
RCE 003
Facing: Inner 1x 12.5mm GTEC Fire
Facing: Outer 1x 12.5mm GTEC Fire or Megadeco Board
Framing: GTEC Edge Channel & CB Clips at 600mm Centres
Fire resistance Columns 90 Minutes up to 280 Hp/A factor
120 Minutes up to 140 Hp/A Factor
Fire resistance Beams 90 Minutes up to 280 Hp/A Factor
RCE 004
Facing: 1x 25mm GTEC Fire Core Board
Framing: GTEC Edge Channel & CB Clips at 600mm Centres
Fire resistance columns: 120 Minutes up to 185 Hp/A factor
Fire resistance beams: 120 Minutes up to 85 Hp/A factor
RCE 005
Facing: Inner 1x 15mm GTEC Fire
Facing: Outer 1x 15mm GTEC Fire or Megadeco Board
Framing: GTEC Edge Channel & CB Clips at 600mm Centres
Fire resistance columns: 120 Minutes up to 235 Hp/A factor
Fire resistance beams: 120 Minutes up to 180 Hp/A Factor
251
INTRODUCTION
INTRODUCTION
System Ref. Component type Component
RCE 006
PARTITIONS
Facing: Inner 1x 25mm GTEC Fire Core Board
Facing: Outer 1x 15mm GTEC Fire or Megadeco Board
Framing: GTEC Edge Channel & CB Clips at 600mm Centres
Fire resistance columns: 120 Minutes up to 280 Hp/A factor
180 Minutes up to 130 Hp/A Factor
Fire resistance beams: 120 Minutes up to 280 Hp/A Factor
180 Minutes up to 80 Hp/A Factor
LININGS
FIRE PROTECTION
FINISHING
Performance values are for imperforate, jointed systems using Siniat GTEC components (metal studs and tracks, boards,
metal accessories, screws and finishing systems) and specified insulation quilt material (type, thickness and density)
and installed to Siniat specification and installation guides.
Maximum heights depend on deflection criteria and applied air pressure.
Hp/A factor
762 x 267 197 70 85
173 80 95 RCE
001 RCE
147 95 110 005
118
686 x 254 170 75 90
100
152 85 95
140 90 105 85
125 100 115 75
610 x 305 238 50 60 RCE
50
179 70 80 001
RCE
149 80 95 RCE
RCE 004
006
610 x 229 140 80 95 002
125 90 105
113 100 115 0
101 110 130 30 60 90 120 180
533 x 210 122 85 95
Fire Resistance (mins)
109 95 110
101 100 115
92 110 125
82 120 140
457 x 191 98 90 105
89 100 115
82 105 125
74 115 135
67 130 150
457 x 152 82 105 120
74 115 130
67 125 145
60 140 160
52 160 180
406 x 178 74 105 125
67 115 140
60 130 155
54 145 170
406 x 140 46 160 185
39 190 220
356 x 171 67 105 125
57 125 145
51 135 165
45 155 185
356 x 127 39 170 195
33 195 225
305 x 165 54 115 140
46 130 160
40 150 180
305 x 127 48 125 145
42 140 160
37 155 180
305 x 102 33 175 200
28 200 225
25 225 260
254 x 146 37 140 170
31 160 200
254 x 102 28 170 200
25 190 220
22 215 250
203 x 133 30 145 180
25 165 210
203 x 102 23 175 210
172 x 102 19 190 230
152 x 89 16 190 235
127 x 76 13 195 240
GTEC FIRE PROTECTION – ENCASEMENT TABLES
253
INTRODUCTION
INTRODUCTION
UNIVERSAL COLUMNS WITH BOX ENCASEMENT
Size of Mass per Section factor Hp/A m-1
steelwork (mm) metre (kg) 3 sides 4 sides
356 x 406 634 15 20 280
551 20 25 RCE
467 20 30 006
393 25 35 230
340 30 35
200 RCE RCE
287 30 45
PARTITIONS
005 007
235 40 50 RCE
003 185
202 45 60
Hp/A factor
356 x 368 177 50 65 RCE
RCE RCE 004
153 55 75
001 001
140
129 65 90 130
305 x 305 283 30 40 100
LININGS
30 120 160
23 155 205
FIRE PROTECTION
254 x 203 81.85 70 90
254 x 114 37.20 130 155
203 x 152 52.09 85 105
152 x 127 37.20 90 120
127 x 114 29.76 100 130
127 x 114 26.79 110 140
114 x 114 26.79 100 135
102 x 102 23.07 105 140
89 x 89 19.35 105 145
76 x 76 12.65 140 185
FINISHING
EXAMPLE OF USE
Beam = 610mm x 305mm x 179kg/m Choice of systems
Exposed on four sides Up to 60mins = RCE001
Hp/A = 80m-1 Up to 90mins = RCE003
REFERENCE
Up to 120mins = RCE004
Up to 180mins = RCE007
GTEC SHAFTWALL
SYSTEMS
The GTEC Shaftwall Fire Protection system protects shafts
and voids in multi-storey buildings with a rapid installation
system preventing continuous routes for the spread of fire.
WHERE TO USE:
GTEC Shaftwall Systems are used to protect voids in commercial or
public multi-storey buildings and is suitable for most construction types.
FEATURES BENEFITS
System designed to be erected from one side only No scaffolding required
Offers fire protection from both directions Provides up to 120 minutes fire performance
Lightweight friction fit framing system Fast to install with less material costs
255
INTRODUCTION
INTRODUCTION
PARTITIONS
GTEC J Track / U Track
GTEC E Stud
fixed to structure
at 300mm centres
LININGS
Mineral wool
FIRE PROTECTION
staggered joints Alternative finishing layer
between layers may be used see tables
GTEC CH Studs
GTEC J Track / U Track at 600mm centres
Deep Flange at base fixed to
structure at 300mm centres GTEC E Studs
fixed at right angles
at 300mm centres
FINISHING
BOARDS
GTEC Fire Core Board See performance tables, p250-253
High strength fire and moisture resistant board for use
in steel fire encasement
FRAME
GTEC CH Stud CH60/B, CHS90/B, CHS146/B
Metal profile for vertical frame elements
INSULATION
Mineral wool insulation See performance table
Provide fire resistance supplied by others
FIX
GTEC Drywall Screws (as appropriate) See screw selector, p334
For connecting plasterboard and metal components
GTEC SHAFTWALL
257
INTRODUCTION
INTRODUCTION
System Component System primary use Product Reference
FINISHING
GTEC Corner and Edge beads n/a
Corner and edge reinforcement
PARTITIONS
Joint reinforcement in conjunction with
GTEC Jointing Compounds
LININGS
FIRE PROTECTION
FINISHING
REFERENCE
SYSTEM GUIDANCE
FRAME AND SHAFT-SIDE BOARDING
FP-SH-101S-Head FP-SH-102S-Base
25mm
GTEC Fire Core Board
GTEC Intumescent
Acoustic Sealant
100mm
GTEC CH Stud
cut 10mm less
GTEC J Track than ceiling height
GTEC J Track
GTEC Fire Board
to suit system
screw fix plasterboard to track
SECTION SECTION
GTEC Intumescent
Acoustic Sealant
GTEC CH Stud
Screw fix at 150mm
staggered centres
GTEC J Track
PLAN
Stagger joints by
minimum 1m FP-SH-202P-Partition assembly – end
GTEC CH Stud
NOTES:
Snip and bend GTEC J Track
Avoid splicing unless necessary temporarily to allow fitting of
final stud and core board
All board joints minimum 450mm from splice
Minimum 4 board fixings between board joint and stud splice mechanically fix GTEC E Stud
to structure at 300mm centres
ISOMETRIC PLAN
GTEC SHAFTWALL
259
INTRODUCTION
INTRODUCTION
FP-SH-203S-Overheight shaftwalls reinforcement – option 1 FP-SH-204S-Overheight shaftwalls reinforcement – option 2
PARTITIONS
Joints within 1/3 height
Joints within 1/3 height
of head or base of shaftwall
50mm
MIn.
GTEC CH Stud
to reinforce joint
GTEC Intumescent
fitted between vertical studs
GTEC Board
GTEC Board
to suit required performance
to suit required performance
SECTION SECTION
Select compatible size (e.g. 90mm stud and GTEC Fire Core Board to be installed before
92mm track) GTEC CH Stud, GTEC E Stud and intermediate stud with construction
GTEC J Track framing elements to suit system proceeding progressively, alternating in
performance. sequence between board and GTEC CH Stud.
Bead of GTEC Intumescent Sealant to be All GTEC CH Studs to be 10mm shorter than
applied at junction of all metal framing with floor to ceiling height except in case of
structure, at junction of all metal framing deflection requirement. Each GTEC CH Stud
with GTEC Fire Core Board, and at all other to be firmly fitted to board and friction fitted
LININGS
locations specified in drawings. into track.
GTEC J Track at head and base to be fixed 100mm deep strip of GTEC Fire Core Board
flat to structure, long leg of track to shaft spanning between studs to be fixed through
side, using appropriate fixings at maximum main GTEC Fire Core Board to GTEC J Track
300mm centres. to form fire stop at head.
FIRE PROTECTION
First GTEC E Stud, 10mm less than floor Where wall height exceeds available GTEC
to ceiling height, to be fixed abutting CH Stud length, lengths of GTEC E Stud to
structure using appropriate fixings at be spliced together, back-to-back, ensuring
maximum 300mm centres. Stud to be fixed overlaps of 600mm for heights below 4m
to head and base track with appropriate and 1000mm for heights above 4m.
GTEC Drywall Screws (see screw selector,
p334-335). Final GTEC E Stud to be Where partition exceeds 3m height,
installed with final GTEC Fire Core Board. horizontal joints to be at alternating
maximum 1/3 or 2/3 height with
Protect base track from moisture with damp reinforcement from GTEC CH Stud
proof membrane when situated on newly laid noggings or 100mm deep strips of
concrete floors. GTEC Fire Core Board.
FINISHING
GTEC Fire Core Board to be 25mm short of Studs and tracks to be clean of fire protective
floor to ceiling height with 25mm gap at top coatings which may have been applied to
of Shaftwall frame. main structure.
INSULATION
Insulation to be of type and thickness to
REFERENCE
GENERAL BOARDING
GTEC Fire Core Board to be used as shaft-side Stagger all board joints between layers
boarding (see p299). and stagger screws by 100mm compared
to adjacent boards and layers.
GTEC Fire Board, Megadeco or Universal
Board, 5mm short of floor to ceiling height, Over-height single layer boarding:
to be used as room-side boarding. Where partition height exceeds board height
fix boards to continuous band of GTEC Flat
Select GTEC Boards by consulting System
Strap FS90/W or GTEC MFIX behind all
Performance Tables (p244-251) to achieve
horizontal joints to maintain fire integrity.
required performance.
Over-height multiple layer boarding:
All layers of boarding to be mechanically
fixed to studs at 300mm centres using Where partition height exceeds board
appropriate GTEC Drywall Screws height for double or multiple layer boarding
(see screw selector, p334-335). fix outer layer of boards to continuous band
of GTEC Flat Strap FS50/RX behind
Board edges to be centred over studs. all horizontal joints.
GTEC Board
to suit required GTEC Movement
performance Control Joint
10mm 10mm
PLAN
Form movement control joints at maximum Fix GTEC Movement Control Joint,
10m intervals in the partition run. butted end-to-end, to board with
sheradised or galvanised staples.
Form movement control joints where the
partition crosses a structural movement joint.
GTEC SHAFTWALL
261
INTRODUCTION
INTRODUCTION
OPENINGS
FP-SH-401P-Door jamb
GTEC J Track
GTEC Intumescent
Acoustic Sealant
PARTITIONS
GTEC Fire Core Board
Timber stud
GTEC E Stud
inside track
PLAN
LININGS
in Construction Detail Drawings.
FIRE PROTECTION
appropriate GTEC Drywall Screws
(see screw selector, p334-335).
FINISHING
REFERENCE
GTEC E Stud
GTEC Intumescent
Acoustic Sealant
GTEC E Stud
PLAN PLAN
GTEC E Stud
PLAN PLAN
GTEC CH Stud
GTEC Board
to suit required
performance
PLAN
GTEC SHAFTWALL
263
INTRODUCTION
INTRODUCTION
FP-SH-506P-Column junction – at corner
See encasement
details for component
information
PARTITIONS
Column encased prior to
shaftwall construction
PLAN
Abutting partitions to coincide with Ensure continuity of GTEC Fire Core Board
Shaftwall stud; additional intermediate at corners.
‘pick-up’ GTEC C Stud; or GTEC Flat Strap
at 600mm vertical centres. See Construction Details Drawings for further
guidance on arrangement and fixing.
Connect studs through plasterboards at
corners and junctions.
LININGS
FIRE PROTECTION
FINISHING
REFERENCE
PENETRATIONS
FP-SH-701M-Duct penetration isometric
GTEC J Track
GTEC CH Studs
between jambs
m
0m
. 60
x
Ma
GTEC Board
to suit required GTEC Fire Core Board
performance screw fixed to GTEC Fire Core Board
GTEC E Stud screw fixed to GTEC J Track
SECTION SECTION
GTEC SHAFTWALL
265
INTRODUCTION
INTRODUCTION
PENETRATIONS
M&E runs and other services to be Ductwork to be independently supported and
pre-planned to minimise or eliminate not supported by the Shaftwall system.
penetrations through rated Shaftwall
systems. Protect all electrical cables in cavity with
conduit.
Continuity of GTEC Fire Core Board to be
maintained around penetration openings.
PARTITIONS
Any penetrations must be fully sealed with
GTEC Intumescent Acoustic Sealant or
other fire resisting material as specified
in Construction Detail Drawings.
LININGS
STAIRWELL SYSTEMS
FP-SH-010P-Stairwelll system FP-SH-011P-Stairwell perimeter detail
GTEC Board to
finish over GTEC
FIRE PROTECTION
Fire Core Board
GTEC Board
to suit required
performance
PLAN PLAN
be transferred to shaft side in accordance of GTEC CH Stud, GTEC E Stud and track.
with system requirements, see performance
tables p244.
GTEC Intumescent
Acoustic Sealant
GTEC U Track
Max. 1200mm
SECTION
Horizontal runs of GTEC Shaftwall systems GTEC Shaftwall duct protection is not
to protect underside of duct work require designed to support ductwork or any
additional material and configurations of other loads.
frame, see performance tables p244-251 for
requirements.
GTEC SHAFTWALL
267
INTRODUCTION
INTRODUCTION
HORIZONTAL SYSTEMS
FP-SH-031S-Horizontal shaftwall
PARTITIONS
GTEC Intumescent GTEC CH Stud
Acoustic Sealant
GTEC E Stud
LININGS
GTEC U Track Deep Flange
FIRE PROTECTION
SECTION
GTEC ENCASEMENT
SYSTEMS
The GTEC Encasement Fire Protection system provides high levels of
fire resistance to structural I-section columns and beams, delaying the
loss of strength in steel which occurs at temperatures over 550°C.
The system uses push-fit GTEC CB Clips to secure GTEC Edge Channel
to the steel. GTEC Fire Core Boards, Fire Boards, and other high
performance boards as detailed in the performance tables, are fixed
to the edge channel to protect columns and beams. Excellent fire
performance is achieved by holding the boards off the columns on a
strong metal frame.
WHERE TO USE:
The system is used in commercial multi-storey construction to ensure
structural safety during fire. The range of impact resistant boards
compatible with the system enables use in high traffic areas.
FEATURES BENEFITS
Uses GTEC Fire Board Economical and effective
269
INTRODUCTION
INTRODUCTION
PARTITIONS
GTEC Edge Channel
push fit into GTEC CB Clip
GTEC Board
M to suit required performance
joi 300 in.
nt
sta mm
gg GTEC Flat Strap
er to reinforce joint
LININGS
GTEC Corner 90º External /
GTEC Flex Tape
to reinforce corner joints
FIRE PROTECTION
FINISHING
REFERENCE
BOARDS
GTEC Fire Core Board See performance tables, p250-253
High strength fire and moisture resistant board for use
in steel fire encasement
FRAME
GTEC CB Clip CB17, CB27, CB40
Steel clip for connecting channels
to structural steelwork
FIX
GTEC Drywall Screws (as appropriate) See screw selector, p334
For connecting plasterboard and metal components
FINISHING
GTEC Corner and Edge beads n/a
Corner and edge reinforcement
271
INTRODUCTION
INTRODUCTION
SYSTEM GUIDANCE
FRAME
FP-EN-101P-Column encasement – single layer
PARTITIONS
GTEC Board
to suit required performance
GTEC CB Clip
at max. 600mm centres
SECTION
LININGS
GTEC CB Clip
at max. 600mm centres
FIRE PROTECTION
GTEC Board
to suit required performance
SECTION
GTEC Intumescent
Acoustic Sealant
Option B – GTEC Metal Angle
fixed to the soffit
Option A – GTEC Metal Angle
fixed to the beam
GTEC CB Clip
at max. 600mm centres
screw fix plasterboard
at 300mm centres
REFERENCE
FRAME
FP-EN-104S-Double boarded beam encasement
GTEC Intumescent
Acoustic Sealant
Option B – GTEC Metal Angle
fixed to the soffit
Option A – GTEC Metal Angle
fixed to the beam
GTEC Board
GTEC Flat Strap / GTEC Fixing Channel to suit required performance
if beam greater than 300mm deep
GTEC CB Clip
at max. 600mm centres
screw fix plasterboard
at 300mm centres
Select GTEC CB Clips to suit flange thickness GTEC CB Clips to be friction fitted to flanges
of steel to be protected: of steel at maximum 600mm centres
beginning at 150mm from both ends of steel.
GTEC CB Clip To fit flange size:
GTEC Edge Channel to be friction fitted into
CB 17 7-17mm GTEC CB Clips along length of steel.
CB 27 17-27mm
Where steel abuts structure GTEC Metal
CB 40 27-40mm Angle to be fixed to structure or shot fired to
inside of steel flange with appropriate fixings,
and following guidance of steel designer, to
provide substrate for plasterboard.
BOARDING
FP-EN-201M-300-600mm beam board reinforcement FP-EN-202M-Over 600mm beam board reinforcement
Over
300 to 600mm
600mm depth
depth
GTEC CB Clip
to
or
mm ngth GTEC CB Clip
00 d le
24 boar
it m
su 0m
60
ISOMETRIC ISOMETRIC
SYSTEM PERFORMANCE
273
INTRODUCTION
INTRODUCTION
Select GTEC Boards by consulting System Where flange/web dimension exceeds
Performance Tables (p250-251) and Hp/A 300mm all plasterboard joints along
tables (p252-253) to achieve required beam/column to be reinforced with
performance. GTEC Flat Strap or GTEC MFIX Channel.
PARTITIONS
using appropriate GTEC Drywall Screws (see to GTEC Edge Channel at maximum
screw selector p334-335). Fixing positions 600mm centres and at board joints.
to be staggered on next boarding layer.
Minimum 2 screws per board edge.
LININGS
GTEC Intumescent
Acoustic Sealant
fix stud
FIRE PROTECTION
through to strap
SECTION
GTEC Intumescent
Acoustic Sealant
SECTION
GTEC Metal
Angle GTEC Intumescent
Acoustic Sealant
GTEC CB Clip
at max. 600mm
centres GTEC Edge Channel
pushed into
GTEC CB Clip
SECTION
GTEC Board
to suit required performance beam encased prior
to partition construction
GTEC Intumescent
fix U track through to GTEC Flat Strap Acoustic Sealant
or fixing channel at 600mm centres
SECTION
275
INTRODUCTION
INTRODUCTION
HEAD DEFLECTION SYSTEM CONTINUITY
GTEC Encasement systems are designed Bead of GTEC Intumescent Acoustic Sealant
to move with beam deflection. Partitions to be applied to perimeter of all runs and in
meeting beams liable to deflection to be all other locations specified in Construction
detailed according to guidance in GTEC C Detail Drawings.
Stud system guidance (see p61).
GTEC Intumescent Acoustic Sealant to seal
PARTITIONS
all other acoustic or air paths to prevent fire/
PENETRATIONS smoke spread and acoustic transmission.
Penetrations must not be made through Full, imperforate system continuity must be
GTEC Encasement systems. maintained to achieve rated performances.
FINISHING
All corners to be reinforced with
GTEC Corner 90.
LININGS
GTEC Finish materials appropriate
to board type to be used.
FIRE PROTECTION
FINISHING
REFERENCE
PARTITIONS
GTEC Taping and Jointing provides a finish to joints between GTEC
boards creating a continuous, fire resistant and easy to decorate
LININGS
FIRE PROTECTION
FINISHING
REFERENCE
i
278 GTEC TAPING AND JOINTING
GTEC TAPING
AND JOINTING
GTEC drywall systems require taping and jointing to complete
the wall surface, reinforce joints to prevent cracking, and
ensure fire and sound performances are achieved.
WHERE TO USE:
Taping and jointing are suitable for large surface areas
where speed and ease of application can greatly reduce
installation cost and drying time.
FEATURES BENEFITS
Applied to low surface areas Quicker than a full plaster skim with less drying
out time
Can be used with automatic taping tools Flexible, high speed application
Two and three stage processes Provides a range of speed and product options
GTEC TAPING AND JOINTING
279
INTRODUCTION
INTRODUCTION
SYSTEM COMPONENT TABLE
BOARDS
All GTEC Boards (see specialist
compounds for Aqua & Megadeco)
Provides wall surface suitable for finishing.
PARTITIONS
FINISHING
GTEC Joint Filler Xtra
Gypsum based joint compound for filling joints
in plasterboards, 90 minute set time
GTEC Smartmix
Ready mixed all purpose jointing compound
suitable for all stages of the jointing process
GTEC Aquamix
Ready mixed all purpose jointing compound for use
with GTEC Aqua system in severe wet applications
LININGS
GTEC Deco Joint Cement
An air drying ready mixed compound for finishing
joints with Megadeco
FIRE PROTECTION
with automatic taping tools to finish joints
with Megadeco
GTEC Aquastrip
Mesh tape for use with GTEC Aqua system to protect
exposed drylining perimeters for wet applications
GTEC Sealers
To seal plasterboard prior to decoration
FINISHING
SYSTEM GUIDANCE
COMPOUND SELECTION
Joint compound selection is largely a matter of However, Aqua Board and Megadeco require
site preference, depending on weather conditions, specific compounds to suit their unique facers.
time and equipment. GTEC Compounds can
be combined in numerous permutations each Taping and jointing is conducted in three
offering a high quality surface finish. main stages: Bedding; Second Coat; and
Finishing Coat.
BEDDING
1 Tape or bead is bedded into the 1
compound and taper filled out
SECOND COAT
The taper is re-filled with 2
compound where required
FINISHING COAT
2 Final compound layer is applied
and sanded for a smooth finish
3
COMPOUND TYPES
All compounds are suitable for Bedding and Air-drying and hybrid compounds are low
Second Coat, however, setting and hybrid shrinkage. Where low shrinkage compounds
compounds reduce overall time required. have been used in Bedding layer the Second
Coat may not be required.
Setting and hybrid compounds must not be
used over air-drying compounds. The drying time of air-drying compounds
is dependent on climatic conditions and
Only air-drying or hybrid compounds are layer thickness. Drying takes approximately
suitable for the final finishing coat. 24 hours but may be extended by adverse
conditions.
GTEC TAPING AND JOINTING
281
INTRODUCTION
INTRODUCTION
Compatible Machine
GTEC Compound Format Type Boards Use Shrinkage Setting Time
PARTITIONS
Easy Finish Xtra Powder All (except
Hybrid No Low 90 mins
Megadeco)
SUBSTRATE
Plasterboard to be tapered edged to Gaps over 3mm to be filled with GTEC Joint
allow GTEC Joint Tape to sit below Filler Xtra or GTEC Easy Finish Xtra.
finished surface for best finish. Square
edged plasterboard may also be jointed Taping and jointing should not be carried
following guidance in drawings. out at extreme temperatures (greater
than 40ºC or less than 5ºC). Do not tape
Board surfaces to be dry, clean, protected and joint on frozen backgrounds.
from weather, secure and evenly fixed.
LININGS
FIRE PROTECTION
TAPING & JOINTING
FN-TJ-101&102M – Tapered edge
Stage 1
ISOMETRIC
20
0m Second coat feathered
m Stage 2
out beyond filling layer
20
0m
m
Finishing layer feathered
out on to plasterboard and Stage 3
sanded once dry
40
0m
m
ISOMETRIC
ISOMETRIC
283
INTRODUCTION
INTRODUCTION
Screws to be spotted with appropriate Square edge joints only:
jointing compound. Joint width to be wider to reduce visible
crowning.
Compound to be applied in nominal
1mm layers. Thicker layers will extend
External corners only:
drying out time.
GTEC Flex Tape to be applied in place of
GTEC Joint Tape cut to length to be pressed GTEC Joint Tape as reinforcement.
PARTITIONS
into bedding compound without trapping air
bubbles, bedding layer of compound to be Machine application:
flush with plasterboard face. Pound to Air-drying compounds only to be used in
be flush with plasterboard face. automatic taping machines.
Second coat of jointing compound if required Setting compounds such as GTEC Joint
LININGS
FIRE PROTECTION
DECORATION
Surfaces and joints to be dry prior to
finishing.
SKIMMING
A traditional skimming plaster finish provides a surface ready to
be decorated and is an alternative to GTEC Taping and Jointing in
certain applications. It is particularly suitable where the quality
of board installation is poor, as it will cover surface imperfections,
and where drying out time is not important.
Vapour Base
Moisture resistant GTEC Boards (GTEC MR Board
Yes None
range and LaDura) to be pre-treated with
bonding agent by others. When using PVAC, Moisture Board Yes Bonding agent
first coat diluted to 5:1, second coat diluted Fire Board Yes None
to 3:1 and skimmed while tacky.
Fire MR Board Yes Bonding agent
Board to be clean of dust, dirt and grease,
Fire V Board Yes None
and sufficiently true to allow the specified
thickness of plaster. Fire Core Board Yes Bonding agent
INTRODUCTION
INTRODUCTION
TILING
Internal dry-lined surfaces are suitable for tiling in a wide variety of
applications in both domestic and commercial applications including
PARTITIONS
showers, toilets and bathrooms as well as permanently wet areas
such as swimming pools.
Advice in the subsequent section is for low, medium, high and severe
humidity applications.
GTEC Board General internal applications Washrooms, toilets, Swimming pool, spa, wet
kitchens, bathrooms rooms, public showers
LININGS
Aqua Board 3 3 3
Moisture Board 3 3 7
LaDura 3 3 7
FIRE PROTECTION
FINISHING
REFERENCE
GTEC Aquamix
bedding layer only
GTEC Joint Tape and
tile adhesive
Tiles by others
Tiles by others
ISOMETRIC ISOMETRIC
TILING
287
INTRODUCTION
INTRODUCTION
SYSTEM GUIDANCE
SUBSTRATE
All surfaces to be clean and dust free with all Where primer is recommended follow
loose material removed. manufacturer’s instructions.
BONDING
PARTITIONS
Tiles to be fixed in accordance with BS 5385. Maximum weight of tiles by type of board at
400mm stud centres:
Ceramic, glazed and stone tiles to be fixed
directly to board using waterproof adhesive Maximum weight of tiles*
which is suitable for plasterboard substrates.
GTEC Moisture Board 32kg/m²
BOARDING
Untiled areas to be taped and jointed, see Drylining systems using GTEC Universal
GTEC Taping and Jointing section, p278. Bonding Compound in their construction to
be allowed 10 days to achieve full strength
LININGS
Taper edge boards to be used to enable before tiling.
formation of flush joints in untiled areas
and to ensure flat substrate for tiling.
FIRE PROTECTION
FINISHING
For concealed joints only GTEC Joint Tape Seal around pipes, baths, shower fittings,
may be bedded with waterproof, ceramic openings and outlets with waterproof
tile adhesive. Untiled areas to be taped and silicone sealant.
jointed using GTEC Aquamix.
In areas of severe humidity GTEC Drywall
In severe humidity areas tiles to be finished Sealer with GTEC Aquastrip to be used to
with suitable waterproof tile grout and protect base of partition/lining.
sealed if required.
GTEC COVE
GTEC Cove provides a decorative feature to the ceiling and wall
junction, masking unsightly cracks and improving the acoustic
mass and sealing along the junction.
WHERE TO USE:
Used in domestic new build or renovation projects
to complement the wall and ceiling junction.
FEATURES BENEFITS
289
INTRODUCTION
INTRODUCTION
SYSTEM COMPONENT TABLE
COVE
GTEC Cove n/a
Gypsum plaster moulding used to finish
the junction of walls and ceilings
PARTITIONS
FIX
GTEC Cove Adhesive n/a
Gypsum based adhesive, 40 minute
setting time for fast fixing of cove
LININGS
FIRE PROTECTION
FINISHING
REFERENCE
SYSTEM GUIDANCE
COVING
FN-CV-101S – Cove 90 and 120
Substrate to be dry, rigid and dust free,
with any wallpaper, whitewash or loose
decoration removed.
64mm
90
m
m
GTEC Cove 90
PLAN
FINISHING
Coat of GTEC Universal Sealer to be applied Plasterboard strips may be added between
to enhance paint coverage and finish. coving and ceiling to add extra stepped
features. Visible edges of plasterboard strips
to be bound edges for decoration.
291
INTRODUCTION
INTRODUCTION
PARTITIONS
FLOORS AND CEILINGS
LININGS
FIRE PROTECTION
SOUTHMEAD HOSPITAL
BRISTOL, UK
Sector: Healthcare
FINISHING
Megadeco
i
REFERENCE
292
293
INTRODUCTION
INTRODUCTION
REFERENCE
PARTITIONS
Product Reference
LININGS
Standards 342
Index 344
FIRE PROTECTION
FINISHING
REFERENCE
i
294 PRODUCT REFERENCE – GTEC BOARD
GTEC BOARD
GTEC Standard Board
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
9.5 1.8 to 2.7 900, 1200 5.95 0.050m2K/W 0.19 ≥ 400N ≥ 160N
12.5 1.8 to 3.0 900, 1200 8.0 0.066m2K/W 0.19 ≥ 550N ≥ 210N
9.5 1.8 to 2.4 900, 1200 5.95 0.050m2K/W 0.19 ≥ 400N ≥ 160N
12.5 1.8 to 3.0 900, 1200 8.0 0.066m2K/W 0.19 ≥ 550N ≥ 210N
GTEC Plank
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
295
INTRODUCTION
INTRODUCTION
GTEC Contour Board
PARTITIONS
gypsum reinforced with chopped strands of glass fibre.
Reaction to fire: Euroclass A2-s1, d0
Finishing: GTEC Contour Board can be jointed and finished
with GTEC Jointing Systems.
Health and Safety: Please read the relevant Health and Safety
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
LININGS
Standards: BS EN 520 Type P
Composition: Aerated Calcium sulphate di-hydrate enclosed inside
a tough paper with bound edges. Core and papers are bonded with
starch. Edge glue is PVA.
Reaction to fire: Euroclass A2-s1, d0
FIRE PROTECTION
Finishing: GTEC Base Board is designed for skim finishing
Health and Safety: Please read the relevant Health and Safety
Datasheet available on our website or through Technical Services
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
9.5 1.8 to 2.7 900, 1200 5.95 0.050m2K/W 0.19 W/mK ≥ 400N ≥ 160N
12.5 1.8 to 3.0 900, 1200 8.0 0.066m2K/W 0.19 W/mK ≥ 550N ≥ 210N
15.0 1.8 to 3.0 900, 1200 10.0 0.079m2K/W 0.19 W/mK ≥ 650N ≥ 250N
9.5 1.8 to 2.4 900, 1200 5.95 0.050m2K/W 0.19 W/mK ≥ 400N ≥ 160N
12.5 1.8 to 3.0 900, 1200 8.0 0.066m2K/W 0.19 W/mK ≥ 550N ≥ 210N
Thickness (mm) Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
297
INTRODUCTION
INTRODUCTION
GTEC Moisture Board
PARTITIONS
papers are bonded with starch. Edge glue is PVA.
Reaction to fire: Euroclass A2-s1, d0
Finishing: GTEC Moisture Board can be jointed and finished
with GTEC jointing systems. The boards require priming with
GTEC Universal Sealer prior to decorating and treating with
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
LININGS
Provides superior fire resistance.
Standards: BS EN 520 Types D and F
Composition: Aerated Calcium sulphate di-hydrate with fire-resisting
fillers and fibres enclosed inside a tough pink paper with bound
edges. Core and papers are bonded with starch. Edge glue is PVA.
FIRE PROTECTION
Reaction to fire: Euroclass A2-s1, d0
Finishing: GTEC Fire Board can be jointed and finished with
GTEC Jointing systems. The boards require priming with
GTEC Universal Sealer prior to decorating.
Health and Safety: Please read the relevant Health and Safety
Datasheet available on our website or through Technical Services
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
12.5 1.8 to 2.4 900, 1200 10.2 0.050m²K/W λR = 0.25 ≥ 725N ≥ 300N
REFERENCE
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
12.5 1.8 to 3.0 900, 1200 10.2 0.050m²K/W λR = 0.25 ≥ 725N ≥ 300N
299
INTRODUCTION
INTRODUCTION
GTEC Fire Core Board
PARTITIONS
bound edges. Core and papers are bonded with starch.
Edge glue is PVA.
Reaction to fire: Euroclass A2-s1, d0
Finishing: GTEC Fire Core Board can be jointed and finished
with GTEC Jointing systems. The boards require priming with
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
GTEC E Board
LININGS
Engineered for use within dwellings to comply with the latest
Building Regulations Approved Document E Regulations.
Standards: BS 520 Type D
Composition: Aerated Calcium sulphate di-hydrate inside tough liner
papers with bound edges. Core and papers are bonded with starch.
Edge glue is PVA.
FIRE PROTECTION
Reaction to fire: Euroclass A2-s1, d0
Finishing: GTEC E Board can be jointed and finished with any of the
GTEC Jointing systems. It can be plastered on either side using single
coat proprietary gypsum finishing plasters not less then 2mm thick.
Health and Safety: Please read the relevant Health and Safety
Datasheet available on our website or through Technical Services
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
301
INTRODUCTION
INTRODUCTION
GTEC Acoustic Homespan MR Board
For use with the GTEC Acoustic Homespan Partition System when
superior moisture resistance is required.
Standards: BS EN 520 Type D and H2
Composition: Aerated Calcium sulphate di-hydrate with fillers and
fibres enclosed inside a moisture resistant paper with bound edges.
PARTITIONS
Core and papers are bonded with starch. Edge glue is PVA.
Reaction to fire: Euroclass A2-s1, d0
Finishing: GTEC Acoustic Homespan MR Board can be jointed and
finished with GTEC Jointing systems. The boards require priming with
GTEC Universal Sealer prior to decorating. Requires PVA treatment
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
Megadeco
LININGS
with acoustic insulation. Unique to Siniat.
Standards: BS EN 520 Type D, F, I and R
Composition: Aerated Calcium sulphate di-hydrate with fillers and
fibres enclosed inside a white pre-sealed paper with bound edges.
Core and papers are bonded with starch. Edge glue is PVA.
Reaction to fire: Euroclass A2-s1, d0
FIRE PROTECTION
Finishing: Megadeco Board can be jointed and finished with only
GTEC Deco jointing systems. The boards require no primer prior to
decorating. The board is not suitable for skim plaster finish.
Health and Safety: Please read the relevant Health and Safety
Datasheet available on our website or through Technical Services
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
LaDura
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
303
INTRODUCTION
INTRODUCTION
Aqua Board
The UK’s first gypsum based board for use in high humidity or
wet applications. Ideal as a tile backing board for bathrooms.
Can also be used as an external sheathing board.
Standards: BS EN 15283 Type GM-F, GM-H1 and GM-I
Composition: Aerated Calcium sulphate di-hydrate with liners
PARTITIONS
made from non woven tissue with fillers and fibres enclosed
inside gypsum core. Core and papers bonded with starch.
Edge glue is PVA. Water resistant additive is silicone oil.
Core contains biocide to prevent mould growth.
Reaction to fire: Euroclass A2-s1, d0
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
LININGS
GTEC Thermal EPS Board
FIRE PROTECTION
a tough paper with bound edges. Core and papers are bonded with
starch. Edge glue is PVA. Expanded polystyrene (EPS) is factory
bonded to 9.5mm board using PVA adhesive.
Reaction to fire: Euroclass B-s1, d0
Finishing: GTEC Thermal Board can be jointed and finished
with GTEC Jointing Systems. The boards require priming
with GTEC Universal Sealer prior to decorating.
Health and Safety: Please read the relevant Health and Safety
Datasheet available on our website or through Technical Services
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
FINISHING
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
305
INTRODUCTION
INTRODUCTION
GTEC Thermal K Board
PARTITIONS
is factory bonded to 9.5mm board with various thicknesses
of using PVA adhesive.
Reaction to fire: Euroclass B-s1, d0
Finishing: GTEC Thermal K Board can be jointed and finished
with GTEC Jointing Systems. The boards require priming with
Thickness Lengths* Widths* Nominal Weight: Thermal Resistance: Thermal Breaking Loads
(mm) (m) (mm) (kg/m2) (R) Conductivity (W/mk) (acc. BS EN 520)
LININGS
(insulation)
FIRE PROTECTION
FINISHING
REFERENCE
Standards: BS EN 14190
Composition: Standard plasterboard with 10mm square perforations
in eight blocks. Perforated area = 16%
Reaction to fire: B-s1, d0
Health and Safety: Please read the relevant Health and Safety
Datasheet available on our website or through Technical Services
Standards: BS EN 14190
Composition: Standard plasterboard with 12mm round perforations
in two blocks. Perforated area = 14%
Reaction to fire: B-s1, d0
Health and Safety: Please read the relevant Health and Safety
Datasheet available on our website or through Technical Services
307
INTRODUCTION
INTRODUCTION
GTEC Pregybel R15 no. 1
Standards: BS EN 14190
Composition: Standard plasterboard with 15mm round perforations
in one block. Perforated area = 16%
Reaction to fire: B-s1, d0
PARTITIONS
Health and Safety: Please read the relevant Health and Safety
Datasheet available on our website or through Technical Services
Standards: BS EN 14190
Composition: Standard plasterboard with 15mm round perforations
in eight blocks. Perforated area = 11%
Reaction to fire: B-s1, d0
Health and Safety: Please read the relevant Health and Safety
Datasheet available on our website or through Technical Services
LININGS
Thickness Lengths* Widths* Nominal Weight: Breaking Loads
(mm) (m) (mm) (kg/m2) (acc. BS EN 520)
FIRE PROTECTION
12.5 2.4 1200 7.23 – –
Standards: BS EN 14190
Composition: Standard plasterboard with 5 x 80mm line perforations
in eight blocks. Perforated area = 11%
Reaction to fire: B-s1, d0
Health and Safety: Please read the relevant Health and Safety
FINISHING
GTEC FRAME
Thickness Width Lengths* Code
(mm) (mm) (m) Ref.
GTEC C Studs
34
309
INTRODUCTION
INTRODUCTION
Thickness Width Lengths* Depth Code
(mm) (mm) (m) (mm) Ref.
PARTITIONS
acoustic insulation over standard 0.52 146 3 AS146/RX
70mm metal studs with the same
board linings
Standards: BS EN 14195
Composition: Galvanised Steel,
hot dipped to BS EN 10346
36
34
GTEC I Stud
LININGS
W Reaction to fire: A1
Health and Safety: Always wear
protective gloves and eyewear
39
GTEC U Track
FIRE PROTECTION
Galvanised U shaped metal section 0.52 45 2.4 30 UT45/RX
used to receive GTEC C Studs to
0.52 52 3 30 UT52/RX
provide framework for wall linings
and partitions 0.52 62 3 30 UT62/RX
Standards: BS EN 14195 0.52 72 3 30 UT72/RX
Composition: Galvanised Steel, 0.52 92 3 30 UT92/RX
hot dipped to BS EN 10346
0.52 148 3 30 UT148/RX
Reaction to fire: A1
30
311
INTRODUCTION
INTRODUCTION
Thickness Width Lengths* Flange Code
(mm) (mm) (m) (mm) Ref.
PARTITIONS
Standards: BS EN 14195
Composition: Galvanised Steel,
hot dipped to BS EN 10346
25
Reaction to fire: A1
50 Health and Safety: Always wear
Reaction to fire: A1
44
Health and Safety: Always wear
LININGS
protective gloves and eyewear
when handling, cutting and fitting
FIRE PROTECTION
Standards: BS EN 14195
Composition: Galvanised Steel,
hot dipped to BS EN 10346
Reaction to fire: A1
30
19
Standards: BS EN 14195
Composition: Galvanised Steel,
hot dipped to BS EN 10346
Reaction to fire: A1
30
313
INTRODUCTION
INTRODUCTION
Thickness Width Lengths* Flange Code
(mm) (mm) (m) (mm) Ref.
PARTITIONS
Standards: BS EN 14195
Composition: Galvanised Steel,
hot dipped to BS EN 10346
Reaction to fire: A1
30
GTEC SR Bracket
LININGS
Composition: Galvanised Steel,
hot dipped to BS EN 10346
Reaction to fire: A1
63
FIRE PROTECTION
when handling and fitting
GTEC XR Bracket
48
GTEC CH Stud
W Reaction to fire: A1
Health and Safety: Always wear
protective gloves and eyewear
when handling, cutting and fitting
PRODUCT REFERENCE – GTEC FRAME
315
INTRODUCTION
INTRODUCTION
Thickness Width Length Code Ref.
(mm) (mm) (m)
GTEC E Stud
PARTITIONS
GTEC Shaftwall System 0.7 146 6.0 ES146/B
Standards: BS EN 14195
Composition: Galvanised Steel,
hot dipped to BS EN 10346
Reaction to fire: A1
35
25
GTEC J Track
LININGS
W
when handling, cutting and fitting
FIRE PROTECTION
of joints cracking due to timber
movement during drying out
45 Standards: BS EN 14195
Composition: Galvanised Steel,
17
GTEC CB Clip
106
Health and Safety: Always wear
protective gloves and eyewear
when handling and fitting
317
INTRODUCTION
INTRODUCTION
Overall Size Coating Max Weight Code Ref.
(mm) (kg)
PARTITIONS
This bracket is capable of supporting
services and a secondary ceiling.
Standards: BS EN 14195
Composition: Zinc galvanised mild steel
/ Moulded neoprene elastomeric rubber
LININGS
Reaction to fire: A1
Health and Safety: Always wear
protective gloves and eyewear
when handling and fitting
FIRE PROTECTION
Metal clip used in the 50 x 30 RAFC25
GTEC Acoustic Floor System
Composition: Spring steel with black
phosphate coating
Reaction to fire: A1
Health and Safety: Always wear
protective gloves and eyewear
when handling and fitting
FINISHING
REFERENCE
319
INTRODUCTION
INTRODUCTION
Flange Width Length Code Ref.
(width) (depth) (m)
PARTITIONS
25 50 3.6 MFC2550
Composition: Galvanised Steel,
hot dipped to BS EN 10346
Reaction to fire: A1
Health and Safety: Always wear
D
LININGS
Reaction to fire: A1
Health and Safety: Always wear
protective gloves and eyewear
when handling, cutting and fitting
FIRE PROTECTION
Thickness Width Length Code Ref.
(mm) (mm) (m)
Reaction to fire: A1
Health and Safety: Always wear
protective gloves and eyewear
when handling, cutting and fitting
REFERENCE
321
INTRODUCTION
INTRODUCTION
GTEC FIX
Size Coverage Application
Guide
Gypsum based compound for direct 25kg bag 8m² Hand only
bonding plasterboard to walls or Internal
walls
bonding GTEC Metal Furring Wall
PARTITIONS
Channels to walls. Suitable for
bonding GTEC Thermal Boards.
Standards: BS EN 14496
Composition: Calcium sulphate
hemihydrate with polymer binders
LININGS
GTEC E-coat
A gypsum based acoustic render for use 25kg bag 5m² Hand
on party walls prior to direct bonding. application
FIRE PROTECTION
only
Robust Detail approved.
Composition: Calcium sulphate
hemihydrate and limestone with
polymer binders
Health and Safety: Please read the
relevant Health and Safety Datasheet
available on our website or through
Technical Services
FINISHING
REFERENCE
65 4.2
75 4.2
90 4.8
90 4.8
100 4.8
75 4.2
90 4.8
323
INTRODUCTION
INTRODUCTION
Length Diameter Head Type Drive Type Thread Point
(mm) (mm)
GTEC Wet Area Drywall Screw
For attaching GTEC Wet 25 3.5 Bugle Phillips 2 Fine Self-drilling
Area boards to various
38 3.5 Fine Self-drilling
substrates.
PARTITIONS
32 3.5 Fine Self-tapping
Standards: BS EN 14566
42 3.5 Fine Self-tapping
Composition: Carbon
steel with ceramic 42 3.5 Coarse Self-tapping
coating
GTEC Drywall Screw – Wafer Head
LININGS
Length Plug Material Pilot Hole Size
(mm)
GTEC Nailable Plugs
FIRE PROTECTION
For the secondary mechanical fixing of 60 Red Plastic 8mm
GTEC Thermal and GTEC Contour Boards
80
when bonded.
100
Standards: n/a
120
Composition: n/a
FINISHING
REFERENCE
GTEC FINISH
Bag Size Coverage Application
(kg) Guide
GTEC Joint Filler Xtra is a gypsum based 12.5 25m² Hand only
joint compound with 90 minute setting Bedding &
Filling
time for bedding tapes by hand application.
Standards: Type 1B to BS EN 13963 37m²
Bedding
Composition: Calcium sulphate hemihydrate only
and limestone with polymer binders
Reaction to fire: A1
Health and Safety: Please read the relevant
Health and Safety Datasheet available on
our website or through Technical Services
325
INTRODUCTION
INTRODUCTION
Size Coverage Application
(kg) Guide
PARTITIONS
easy sanding. Can be used for bedding 135m2
tapes and finishing joints in a 2-stage Finishing
application. Ideal for machine application. Coat Only
GTEC Aquamix
LININGS
Health and Safety: Please read the (20kg)
relevant Health and Safety Datasheet
available on our website or through
Technical Services
FIRE PROTECTION
GTEC Deco Filler
327
INTRODUCTION
INTRODUCTION
Roll Size Nominal Width
(m) (mm)
GTEC Joint Tape
PARTITIONS
GTEC Jointing Compounds.
Standards: BS EN 13963
Health and Safety: Please read
the relevant Health and Safety
Datasheet available on our
website or through Technical
LININGS
corner angles.
Health and Safety: Please read
the relevant Health and Safety
Datasheet available on our
website or through Technical
Services
FIRE PROTECTION
GTEC Aquastrip
Galvanised steel angle bead with 3mm nose for drywall 2400
corner reinforcement.
3000
Health and Safety: Always wear protective gloves and
eyewear when handling, cutting and fitting
Reaction to fire: A2
Health and Safety: Please read the
relevant Health and Safety Datasheet
available on our website or through
Technical Services
PRODUCT REFERENCE – GTEC FINISH
329
INTRODUCTION
INTRODUCTION
Length
(mm)
GTEC Cove 90
PARTITIONS
of walls and ceilings.
Standards: BS EN 14209
Composition: Calcium sulphate
di-hydrate enclosed inside a tough
paper with bound edges
LININGS
Reaction to fire: Euroclass A2-s1, d0
Health and Safety: Please read the
relevant Health and Safety Datasheet
available on our website or through
Technical Services
FIRE PROTECTION
Bag Size Coverage Guide Application
(kg)
GTEC Socket Pads are used to protect 170 x 170 4 Single PAD1
the fire and acoustic integrity of socket
230 x 170 4 PAD2
partitions where electrical sockets
Double
are used. socket
SYSTEM PERFORMANCE
Stud (CS)
44 50 60 70 90 146 RX
36
34
36
34
36
33
44 50x 60 x7070
xwidth
width 90
(mm) 146Gauge
90 146
(mm) GaugeRX
B
(CS)
(CS)
x x 60 x x 90 90 x RXW
C Stud (CS)
44
44 50
50 60 70 70 90 146
36
34
36
34
36
33
146 RX
36
34
36
34
36
33
StudC
width width width – –xxx xx–x width
xxx7070x 90
90 146
90
90 146
(mm) BY
146Gauge
B B
Stud
70 146
CC(CS)
xx 50
44 xx 60 xx 70xx 90
90 146xx W
RX
W
36
34
36
34
36
33
GTEC C Studwidth
– RX and B gauge GTEC C Stud – Wwidth
gauge GTEC C Stud –width
Y gauge – –xx x– x xx –70 xx 90
90
90 146 – YYB W
C Stud
width width width 146
(CS) (CS) (CS)
x x x x 90 x W
GTEC
GTEC C
C Stud –
– RX
RX and
and B
B gauge GTEC
GTEC C
C Stud
Stud –
–W gauge GTEC
GTEC C
C Stud
Stud – Y
Y gauge
Studwidth gauge Wwidth
gauge – width
gauge – –x – x x – x 90 90 146146 Y Y
(CS)
(CS) (CS)
(CS) (CS)
(CS)
GTEC C Stud – RX and B gauge GTEC C Stud – W gauge GTEC C Stud – Y gauge
(CS) (CS) (CS) width (mm) Gauge
UT 45Width 72 92 148 RXGauge
52 62(mm)
70
x 52width
62 72 92 148Gauge B
UDT width (mm)
(mm) Gauge
50
min. 27
x 52 62 x 72x x 148 x Y
UT 45UT 45
45 52
UT 52 526262 72 92
72 9292148148RX
RX RX
70
UDT 62 72
UXT x 52 width 92 148
(mm)
72 148 B
50
UDT xx 52
50
27
x xx x 72 xx xx YB
– UT52 6262x 72 x92 148
x148RX B
min.27
45 52
x 52 72
x 92 Y
width width width
70
xx 52
xx 62
xx x72 92 148 W
min.
UXT
x x xx B
min. 27
– x 52x x 72 B
52Y – – – – Y
GTEC U Track
width GTEC U Track Deep Flange
width GTEC U Trackwidth
Extra Deep Flange
width width width x x x x 92 148 W
(UT) (UDT) (UXT) UXT
x x x 72 x x B
GTEC
GTEC U
U Track
Trackwidth GTEC
GTEC UU Track
Track Deep
Deep Flange
Flange GTEC
GTEC UU Track Extra
Extra Deep
Track width Deep Flange
Flange
– – – – 92 148 W
width
(UT)
(UT) (UDT)
(UDT) (UXT)
(UXT) UXT
GTEC U Track GTEC U Track Deep Flange GTEC U Track Extra Deep Flange – – – 72 – – B
(UT) 39 (UDT) (UXT)
39
39
Width (mm)
width (mm) Gauge
Gauge
39 AHS 44 50 x x x x RX
36
34
36
38
xwidth
width (mm)
(mm) Gauge
IS 44
AHS x 50
50 xx xx xx xx RX
RX
36
AHS 44 50 x x x x RX
34
36
38
36
x x 70 90
38
width width AS x 70
width 70 90 146
(mm) 146 Gauge
RX
IS xx 50
IS
AHS 44 50 xx xx xx xx RX
RX
36
34
38
70 B
70 90
W
width
width 60 90 B
width
GTEC I Stud width Homespan Stud
GTEC Acoustic GTEC Acoustic Stud IS IS x 50 x x x x RX
(IS) (AHS) (AS)
width
– – x 60x 6070 70 9090 x – B B
GTEC width
GTEC II Stud
Stud GTEC
GTEC Acoustic
Acoustic Homespan
Homespan Stud
Stud GTEC
GTEC Acoustic
Acoustic Stud
Stud
(IS)
(IS) (AHS)
(AHS) (AS)
(AS)
GTEC I Stud GTEC Acoustic Homespan Stud GTEC Acoustic Stud Gauge Thickness RX 0.52mm
(IS) (AHS) (AS) B 0.70mm
GTEC ACCESSORIES
W 0.90mm
GTEC STUD AND TRACK PROFILES Y 1.2mm
GTEC
GTEC
GTEC FlatACCESSORIES
ACCESSORIES
Strap
GTEC ACCESSORIES
GTEC
GTEC
GTEC Flat ACCESSORIES
Flat Strap
50
Strap 45 106 41
(FS50/RX) width (mm) Gauge
C Stud (CS)
GTEC Flat50
Strap
17
50 45
45 106 41
44 50 60 70 90 146 RX
11
36
34
36
106
34
36
33
41
(FS50/RX)
(FS50/RX)50 x x x 70 90 146 B
17
90 45 18
17
106 x x x x 90 x W
1111
41
(FS90/W)
(FS50/RX) width width
GTEC Resilient Bar GTEC Acoustic Vwidth
Brace x Control
GTEC Movement x x Joint
x 90 146 Y
90 18
17
UT 45 52 62 72 92 148 RX
70
x 52 62 72 92 148 B
25
UDT
50
23
min. 27
50
x 52 x x x x Y
6
50
x x x x 92 148 W
UXT
25
25 25 30
25
23
98 x x x 72 x x B
50
23
66
(MFC2550)
25 (MFC2525)
25 (MFC2330)
30 GTEC Fixing Channel 98
23
98
6
GTEC U Track GTEC U Track Deep Flange (MFIX/W) GTEC U Track Extra Deep Flange
(MFC2550) (UT) (MFC2525) (UDT)
(MFC2330) GTEC (UXT)
25
(MFC2550) 25
(MFC2525) 30
(MFC2330) GTEC Fixing
Fixing Channel
Channel 98
(MFIX/W)
(MFIX/W)
(MFC2550) (MFC2525) (MFC2330) GTEC Fixing Channel
(MFIX/W) All dimensions are in mm
39
All dimensions are in mm
All
All dimensions
dimensions are
are in
in mm
mm
width (mm) Gauge
All dimensions are in mm
44 50 x x x x RX
AHS
36
34
36
38
W
AS x x x 70 90 146 RX
IS x 50 x x x x RX
width x x 60 70 90 x B
PROFILE GUIDE
333
INTRODUCTION
INTRODUCTION
Gauge Thickness RX 0.52mm
B 0.70mm
Gauge Thickness RX 0.52mm
W 0.90mm
GTEC SUSPENDED MF CEILING PROFILES B
Y
0.70mm
1.2mm
W 0.90mm
GTEC SUSPENDED MF CEILING PROFILES Y 1.2mm
GTEC SUSPENDED MF CEILING PROFILES
PARTITIONS
30 30
30 30
25
19
15
25
19
26
15
50 44
52
26 44
50
52
GTEC Edge Channel GTEC Ceiling Channel GTEC Primary Channel GTEC Heavy Guage Primary Channel
(MFCE26) (MFC50) (MFCP44) (UT52/Y)
20 20
17
19
17
19 47
47
GTEC Dryliner Track GTEC Dryliner Channel
133 133
(RD9) (RD1)
GTEC Dryliner Track GTEC Dryliner Channel
(RD9) (RD1)
63 63
LININGS
43
43
10
15
48
10
30
15
18 48
30 48 48
GTEC18
Shallow Wall Channel GTEC CR Bracket GTEC XR Bracket GTEC SR Bracket
(MFCS/RX) (RD7) (RD11) (RD2)
GTEC Shallow Wall Channel GTEC CR Bracket GTEC XR Bracket GTEC SR Bracket
(MFCS/RX) (RD7) (RD11) (RD2)
FIRE PROTECTION
Gauge Thickness RX 0.52mm
B 0.70mm
W 0.90mm
GTEC STUD AND TRACK PROFILES Y 1.2mm
70 90 146 RX
Width (mm) 44Gauge
50 60
36
34
36
34
36
33
x x x 70 90 146 B
width (mm) Gauge
x x x x 90 x W
50 50
JT 62 92 148 B
width width width JT
62 92 148 x Bx x x 90 146 Y
width (mm) Gauge
35 35
25
25
ES 60 90
ES 60 90 146 BB
GTEC C Stud – RX and B gauge GTEC C Stud – W gauge GTEC C Stud – Y gauge JT 62 92 146148 B
CHS 60 90 146 B
25
ES 60 90 146 B
width width CHS 60 90 146 B
CHS 60 90 146 B
GTEC J Track width GTEC E Stud width
(JT) (ES)
FINISHING
x 52 62 72 92 148 B
UDT
50
min. 27
x 52 x x x x Y
x x x x 92 148 W
depth
35 35
UXT
Depth
depth (mm)x (mm)
x x 72 x x B
depth
width
GTEC CH Stud GTEC CB Clip
(CHS) (CB)
GTEC CH Stud GTEC CB Clip
(CHS) 39 (CB)
All dimensions
All dimensions are in mm
are in mm
All dimensions are in mm
width (mm) Gauge
AHS 44 50 x x x x RX
i
36
34
36
38
AS x x 70 90 146 RX
IS x 50 x x x x RX
width x x 60 70 90 x B
334 SCREW SELECTION GUIDE
SCREW
SELECTION GUIDE
GTEC Drywall Screws are a comprehensive range of mechanical fixings
essential for use in GTEC systems. All screws have been rigorously tested for
mechanical characteristics such as shear and pull-out, allowing the design of
systems with superior levels of structural performance. Only the use of
GTEC screws will enable maximum heights and loadings to be achieved safely.
GTEC Drywall Screws are fully CE marked and compliant with BS EN 14566.
Fixing boards to Timber Board(s) Coarse, self-tapping GTEC Wet Area High
timber framing Thickness Thread Drywall Screw
in wet areas + 25mm
Fixing boards to Thin gauge metal Board(s) Fine, self-tapping GTEC Wet Area
metal framing in All Rx (0.52mm) & Thickness Self-Tapping
wet areas B (0.7mm) + 10mm Drywall Screw
Fixing boards to Thick gauge metal Board(s) Fine, self-drilling GTEC Wet Area
metal framing in W (0.9) & Y (1.2) Thickness Self-Drilling
wet areas + 10mm Drywall Screw
Fixing metal to metal n/a All metal gauges n/a Fine, self-drilling GTEC Wafer Head
Drywall Screw
335
INTRODUCTION
INTRODUCTION
SCREW SELECTION RF-SC-001-Fixing to metal framing
PARTITIONS
for 15mm boards.
CUT EDGES BOUND EDGES
For timber substrates minimum length of
screws to be total board thickness plus
25mm penetration into the substrate.
Min.10mm
SCREW POSITIONING
Screws to be located minimum of 10mm
from bound edges.
LININGS
minimum of 6mm from edge of stud.
FIRE PROTECTION
GTEC Partitions – 300mm. See section for
more detailed guidance.
High thread,
FINISHING self-tapping
SUSTAINABILITY
SINIAT AND SUSTAINABILITY
4 Plasterboard is fully recyclable – with no loss in quality
4 GTEC Products and Systems are BRE Green Guide A and A+ rated and help collect
sustainability code credits
4 Unique product innovations minimise the number of boards needed in a design
4 Certified and managed sustainability: Responsible Sourcing BES 6001,
ISO 9001 and ISO 14001
4 Full plasterboard site waste collection and recycling from GTEC Wasteline Direct
337
INTRODUCTION
INTRODUCTION
OUR SUSTAINABILITY POLICY: GYPSUM WASTE RECYCLING
A LIFE CYCLE APPROACH
An outstanding sustainability credential
To meet your client’s sustainability targets, of plasterboard is that it can be recycled
Siniat takes a life cycle approach to minimising into new board products with no loss
the environmental impacts of manufacturing in quality. Siniat has been recycling
and supply operations. plasterboard process waste for many years,
PARTITIONS
becoming the first to eliminate plasterboard
All of our plant and supply chain activities manufacturing waste to landfill in 2005.
translate into embodied impacts (such as
carbon, water and recycled content) within your We are now one of the leading recyclers
construction project. Therefore, we intervene at of plasterboard waste in the UK.
every life cycle stage to reduce these through
material and energy resource minimisation,
LININGS
endeavour to recycle the waste back into new
Whilst all drywall projects generate waste from plasterboard wherever viable. Where this is
off-cuts, steps can be taken to minimise this. not possible, we direct the recovered gypsum
Our project teams can help you reduce waste to other favourable uses approved by the
through selecting appropriate products and Environment Agency. GTEC Wasteline Direct
systems, and efficient design detailing. Where will not landfill any clean plasterboard waste
necessary, we can supply boards and metal studs
FIRE PROTECTION
recovered by the scheme.
in non-standard lengths to reduce wastage on
site. Reducing damage to boards and pallets An up-to-date list of the GTEC products accepted
with good site storage and transport practices by the scheme is available on our website where
can also make a big contribution. you can also request a service cost quotation.
Or, telephone 01275 377579 or email
gtecwasteline@siniat.co.uk
FINISHING
REFERENCE
2. Power Station
3. Paper Mill
Natural
Gypsum
by ship
By-product
Gypsum by
Rail Paper
by road
4. Plasterboard
Plant
Recycled
Paper
5. & 6.
Products Recycled
Gypsum
Construction Site
7. Board Recycling Plant
1. All our supply quarries have a biodiversity rehabilitation 5. Packaging is the second largest source of waste
plan with state-of-the-art replanting. Delivery by bulk in construction. Against a national target of 20%
shipping is 20 times more carbon efficient than road Siniat reduced packaging by over 50% following
transport. investments of over £1 million. The bearers
used for board packaging are from certified
2. Flue Gas Desulphurisation (FGD) systems used in and sustainable sources.
power stations eliminate sulphur dioxide emissions
and produce high purity gypsum as a by-product. 6. We pioneered the use of fuel-saving ‘teardrop’ trailers
All our FGD gypsum supplies are delivered by to limit the impacts of product delivery. Coupled
carbon efficient rail transport. with LPG conversion the carbon footprint of our
distribution activities has been reduced by 10%.
3. The plasterboard liners we use comprise 100%
recycled paper, principally from post-consumer 7. Almost all GTEC Plasterboards are fully recyclable
packaging. into new products. The gypsum and paper are
separated, with both suitable for closed-loop
4. Our manufacturing process has very few emissions recycling. Our GTEC Wasteline Direct service offers
as all process water and waste is recycled a plasterboard recovery and recycling service.
internally. Zero waste goes to landfill. Our £1.6
million investments in energy efficiency saved over
40,000 tonnes of carbon dioxide by 2010.
SUSTAINABILITY
339
INTRODUCTION
INTRODUCTION
SUSTAINABLE CONSTRUCTION
GTEC PRODUCTS AND SYSTEMS RESPONSIBLE SOURCING AND BES6001
FOR SUSTAINABLE BUILDINGS Siniat was the first manufacturer in the UK
As well as meeting regulation standards, to offer plasterboard products certified to
our high performance products and systems the BRE Environmental and Sustainability
enhance the sustainability of your building Framework Standard for the Responsible
projects in many ways: Sourcing of Construction Products,
BES6001. Our review in 2012 extended
PARTITIONS
Thermal boards contribute to the our rating to the ‘Very Good’ grading.
conservation of energy and CO2 emissions
This certificate may be downloaded from BRE’s
Fire boards contribute to safety as well as Green Book Live website: www.greenbooklive.com.
building durability When using GTEC products on your projects, you
can collect credits within the Materials section in
LININGS
eliminating sealing on site.
LaDura
LaDura offers similar resource efficiency
plus metal stud savings, due to its high
strength. Excellent durability will reduce
the need for maintenance.
FIRE PROTECTION
Weather Defence
This unique board for external applications
offers major carbon reductions compared to
the cementitious boards traditionally used.
Excellent stability provides superior air-
tightness of the building envelope. Weather
Defence offers improved recyclability and
eliminates dust exposure for installers.
FINISHING
REFERENCE
GTEC systems achieve the high sound insulation values necessary to gain the credits for exceeding Building
Regulation requirements.
In the Materials Section, the excellent BRE Green Guide ratings of GTEC Systems and our BES6001 certification for
Responsible Sourcing both access credits.
Our plasterboard waste recovery service, GTEC Wasteline Direct, can support your site waste management needs
and is also eligible for credits.
Durability credits are available where Severe Duty partitions are used in corridors and public areas.
The zero release of VOC’s (volatile organic compounds) from GTEC boards contributes to Indoor Air Quality.
Specification of Megadeco can also minimise the release of VOC’s during the build.
Siniat supports contractors during construction in areas relevant to Project Management credits, e.g. by minimising
construction site impacts. Drawing on their vast experience with all building types,our projects team will support
achievement of the best possible BREEAM.
HEALTH AND SAFETY
341
INTRODUCTION
INTRODUCTION
HEALTH AND
SAFETY
PARTITIONS
Siniat has a deep commitment to zero harm in our industrial activity. We follow
an active policy for continuous improvement in reducing incidents and protecting
LININGS
(e.g. reaction to fire or tensile strength) are type tested in
main raw material used in our products; evidence and our
accredited laboratories. Our ISO9001 quality management
REACH registration number is available on request.
processes ensure continuing compliance. Declarations of
Performance confiming compliance with CE marking to
Siniat board products do not contain or emit volatile organic
the Construction Products Regulation are available from
compounds (VOCs) and our pre-finished Megadeco Board
www.siniat.co.uk/DoP.
removes the need for on-site sealing, further enhancing the
indoor air quality of your projects.
MANUAL HANDLING
FIRE PROTECTION
The sealing products in the Siniat GTEC range have an
In collaboration with the Health & Safety Executive, Siniat aqueous base and contain VOCs at the lowest classification
has introduced weight labelling on all UK-produced board level under the current regulations (<30g/litre).
products. This information helps users to reduce injuries
through risk assessment. All GTEC products are classified as non-hazardous according
to the CLP (EU) Regulations and are stable and non-reactive
Example of product marking: with other building materials.
25kg Safety Data Sheets are available for all GTEC products
HANDLE
covering handling, storage, use and disposal. Latest versions
FINISHING
SAFELY
from our Technical Services.
STANDARDS
GTEC PRODUCT STANDARDS AND TESTS
BS EN 520 BS EN 14353
Gypsum plasterboards. Definitions, Requirements Metal beads and feature profiles for use with gypsum
and Test Methods. plasterboards. Definitions, Requirements and Test
Methods.
BS EN 14190
Gypsum plasterboard products from reprocessing. BS EN 14209
Definitions, Requirements and Test Methods. Preformed plasterboard cornices.
Definitions, Requirements and Test Methods.
BS EN 13950
Gypsum plasterboard thermal/acoustic insulation composite BS EN 13963
panels. Definitions, Requirements and Test Methods. Jointing materials for gypsum plasterboards.
Definitions, Requirements and Test Methods.
BS EN 15283
Gypsum boards with fibrous reinforcement – Definitions, BS EN 14496
Requirements and Test Methods. Gypsum based adhesives for thermal/acoustic insulation
• Part 1: Gypsum board with mat reinforcement composite panels and plasterboards. Definitions,
Requirements and Test Methods.
BS EN 14195
Metal framing components for gypsum plasterboard systems. BS EN 13964
Definitions, Requirements and Test Methods. Suspended Ceilings – Requirements and Test Methods.
BS EN 14566
Mechanical fasteners for gypsum plasterboard systems.
Definitions, Requirements and Test Methods.
BS 8212 BS 5250
Code of practice for dry lining and – Partitioning using Code of Practice for the control of condensation in
gypsum plasterboard buildings
BS 8000 BS 5385
Workmanship on building sites Wall and floor tiling – Code of practice
• Part 8: Code of practice for plasterboard – Partitions and • Part 1: Design and installation of ceramic, natural stone and
dry linings mosaic wall tiling in normal conditions
• Part 4: Design and installation of ceramic and mosaic tiling
BS EN 13914 in special conditions
Design, preparation and application of external rendering and
internal plastering BS EN ISO 6946
Building components and building elements.
BS 5234 Thermal resistance and thermal transmittance.
Specification for performance requirements for strength and Calculation method.
robustness
• Part 1: – Partitions (including matching linings) – Code of BS 9999: 2008
practice for design and installation Code of Practice for fire safety in the design, management
and use of buildings
STANDARDS
343
INTRODUCTION
INTRODUCTION
TEST METHODS
PARTITIONS
robustness.
• Part 7: Method for classification of the surface spread
• Part 2: Partitions (including matching linings) –
of flame of products
Specification for performance requirements for strength
• Part 20: Methods for determination of the fire resistance and robustness including methods of test
of elements of construction (general principles)
• Part 21: Method for determination of the fire resistance BS EN ISO 717
of loadbearing elements of construction Acoustics. Rating of sound insulation in buildings and of
LININGS
• Part 3: Beams heat of combustion (calorific value).
FIRE PROTECTION
to the fire resistance of structural members
MISCELLANEOUS
BS EN 13279 BS EN 13164
Gypsum binders, and gypsum plasters. Thermal insulation products for buildings. Factory
• Part 1: Definitions and requirements made products of extruded polystyrene foam (XPS).
• Part 2: Test methods Specification.
BS EN 10346 BS EN 13165
Continuously hot-dip coated steel flat products. Thermal insulation products for buildings. Factory made rigid
Technical delivery conditions. polyurethane foam (PUR) products. Specification.
FINISHING
BS EN 13163
Thermal insulation products for buildings. Factory made
products of expanded polystyrene (EPS). Specification.
INDEX
A acoustic sealant, Intumescent Acoustic
Sealant 330
boards 12–13, 294–307
alternative configurations 14–15
acoustic board see Acoustic Homespan Acoustic Stud 309, 332 Acoustic Homespan Board 300
Board; dB Board; LaDura; Universal;
Acoustic Stud Partition Systems 72–8 Acoustic Homespan MR Board 301
Megadeco
acoustic T-junctions Aqua Board 303
Acoustic Floor Clip 317
Acoustic Homespan Partition Base Board 295
Acoustic Floor Systems 137, 170–6
Systems 86 Contour Board 295
Acoustic Homespan Board 300
Acoustic Stud Partition Systems 78 dB Board 300
Acoustic Homespan C Studs 308
C Stud Partition Systems 59 E Board 299
Acoustic Homespan MR Board 301
Resilient Bar Partition Systems 93 Fire Board 297
Acoustic Homespan Partition Systems
Timber Partition Systems 118 Fire Core Board 299
43, 80–6
Twin Frame Partition Systems 103 Fire MR Board 298
Acoustic Homespan Starter Studs 308
Acoustic V Brace 316, 332 Fire V Board 298
Acoustic Homespan Stud 332
Acoustic V Brace 90° 230, 316 LaDura 302
acoustic mass barrier ceilings 147
adhesive Megadeco 301
acoustic performance 17
Cove Adhesive 329 Moisture Board 297
Acoustic Floor Systems 137
Wall Lining Adhesive 321 Plank 294
Acoustic Homespan Partition
Aqua Board 13, 303 Pregybel Boards 306–7
Systems 43
Aqua Board Partition Systems 26–7 Render Board 303
Aqua Board Partition Systems 26–7
Aquamix 325 Standard Board 294
Ceiling Systems to Timber Floors 126
Aquastrip 327 Thermal Board 304
dB Board Partition Systems 33–7
Dryliner Ceiling Systems to Concrete Thermal K Board 305
B
Soffit 127 Thermal PIR Board 305
E Board Partition Systems 44 Thermal XP Board 304
Engineered Joist Systems 122 Base Board 295 Universal Board 302
Fire Board Partition Systems 38–40 beading products 328 Vapour Base Board 296
Horizontal Shaftwall Systems 249 beams Vapour Board 296
LaDura Partition Systems 22–5 fire resistant encasement 252, 271–2, bonding
274
Lining Systems To Framed External Contour Lining System 205
Walls 187 head deflection 63
Direct Bond Lining Systems 196–7
Lining Systems To Upgrade Internal boarding details
Shallow Wall Lining Systems 211–12
Walls 182–3 Acoustic Floor Systems 174–6
Tiling 287
Mass Barrier Ceilings 136 Acoustic Homespan Partition
Universal Bonding Compound 321
Megadeco Partition Systems 28–31 Systems 84
BRE Green Guide 339
Pregybel Independent Lining Systems Acoustic Stud Partition Systems 76
breaking loads, Board 294–307
190–1 C Stud Partition Systems 55–6
BREEAM (Building Research
Pregybel MF Ceiling Systems 131–2 Contour Lining System 206
Establishment environmental
Separating Floor Systems 128–30 Direct Bond Lining Systems 198 Assessment Method) 336
Shaftwall Stairwell Systems 248 Direct-to-Timber Ceiling Systems British Standards 342–3
Shaftwall Systems 244–7 166–7
BS 476-21 122–37
Standard Board Partition Systems 41–2 Dryliner Ceiling Systems 158–9
BS 476-22 22–49, 135–6, 244–9
Structural Frame Partition Systems 45 Dryliner Lining Systems 221
BS 5234-2 18, 22–49, 244–9
Suspended MF Ceiling Systems to Independent Wall Lining Systems 231
BS EN 1364-1 22–49, 244–8
Protect Structure 135 Pregybel Independent Lining Systems
BS EN 1364-2 135–6, 249
Suspended MF Ceiling Systems to 239–40
BS EN 1365-2 122–37
Timber Floors 133–4 Pregybel MF Ceiling Systems 152
BS EN ISO 140 17
Timber Partition Systems 47–9 Resilient Bar Partition Systems 91
BS EN ISO 717 17
Universal Board Partition Systems 32 Shaftwall Systems 258–60
BS EN ISO 11654 131–2
Masonry Robust Detail Systems 46 Shallow Wall Lining Systems 212
Suspended MF Ceiling Systems 143
Timber Partition Systems 115–16
Twin Frame Partition Systems 100–1
INDEX
345
INTRODUCTION
INTRODUCTION
Building Regulations
acoustic performance 17
Ceiling Systems to Timber Floors 126
ceramic tiling 285–7 D
dB Board 300
compliance with Approved Document CH Stud 314, 333
E 299 dB Board Partition Systems 33–7
Code for Sustainable Homes 340
PARTITIONS
fire performance 16 Deco Filler 325
codes of practice 342
thermal performance 11 Deco Joint Cement 326
Collated Drywall Screws 323
Building Research Establishment Deco Machine 326
columns, fire resistant encasement
environmental Assessment Method 253, 263, 271, 273 decoration 283
(BREEAM) 336 composition deflection heads see head deflection
Building Research Establishment Green Board 294–307 design codes 342
LININGS
C Stud Partition Systems 57–8
Ceiling Channel 311, 333 Direct Bond Lining Systems 200
Direct Bond Lining Systems 199
ceiling channel splicing 141 Dryliner Lining Systems 223
Resilient Bar Partition Systems 92
ceiling height change Encasement Systems 273
Shallow Wall Lining Systems 213
Dryliner Ceiling Systems 160 Independent Wall Lining Systems 233
Timber Partition Systems 117
Pregybel MF Ceiling Systems 153 Pregybel Independent Lining Systems
Twin Frame Partition Systems 102
Suspended MF Ceiling Systems 145 240
FIRE PROTECTION
Dryliner Ceiling Systems 154–61
ceiling systems Resilient Bar Partition Systems 93
Dryliner Ceiling Systems to Concrete
Ceiling Systems to Timber Floors 126 Shaftwall Systems 262
Soffit 127
Direct-to-Timber Ceiling Systems Shallow Wall Lining Systems 214
Dryliner Channel 312, 333
162–8 Timber Partition Systems 118
Dryliner Channel Connector 314
Dryliner Ceiling Systems 154–61 Twin Frame Partition Systems 103
Dryliner Lining Systems 216–24
Dryliner Ceiling Systems to Concrete corners, taping and jointing 282, 328
Soffit 127 Dryliner Profiles 333
Cove 288–90, 329
Mass Barrier Ceilings 136 Dryliner Track 313, 333
Cove Adhesive 329
Pregybel MF Ceiling Systems 131–2, Drywall Screws 322–3, 334–5
curved partitions
148–53 Drywall Sealer 328
C Stud Partition Systems 70–1
Separating Floor Systems 128–30 duct penetrations, Shaftwall Systems
Contour Board 295 264–5
Suspended MF Ceiling Systems
Contour Lining Systems 202–6 duct protection systems 266
138–47
FINISHING
INDEX
E Fire Board 297
Fire Board Partition Systems 38–40
fire protection systems 244–75
Encasement Fire Protection Systems
E Board 299 250–3
Fire Core Board 299
E Board Partition Systems 44 Encasement Systems 268–75
Fire MR Board 298
E Stud 315, 333 Horizontal Shaftwall Systems 249
fire performance 16
Easy Finish Xtra 324 Shaftwall Stairwell Systems 248
Acoustic Floor Systems 137
E-coat 321 Shaftwall Systems 244–7, 254–67
Acoustic Homespan Partition
Edge Channel 311, 333 Systems 43 Fire V Board 298
Edging Bead 328 Aqua Board Partition Systems 26–7 Fixing Channel 319, 332
educational projects 7 Board 294–307 fixing details see boarding details
electrical services see cable tray Ceiling Systems to Timber Floors 126 fixing options 69
penetrations
dB Board Partition Systems 33–7 fixing products
Encasement Fire Protection Systems
Dryliner Ceiling Systems to Concrete bonding and adhesives 321
250–3, 268–75
Soffit 127 Drywall Screws 322–3
Engineered Joist Systems 122
E Board Partition Systems 44 fixtures
environmental issues 336–9
Engineered Joist Systems 122 C Stud Partition Systems 67–8
external insulation 184–7
Finish 324–30 Suspended MF Ceiling Systems 146
Fire Board Partition Systems 38–40 Flat Strap 319, 332
F Fix 321
Frame 308–20
Flex Tape 327
Flex Track Deep Flange 310
finishing 278–90
Horizontal Shaftwall Systems 249 floor systems 121
Board 294–307
LaDura Partition Systems 22–5 Acoustic Floor Systems 137, 170–6
Taping and Jointing Systems 278–83
Lining Systems To Framed External Engineered Joist Systems 122
Tiling 287 Walls 187 Plank 294
skim plastering 284 Lining Systems To New External Walls Separating Floor Systems 128–30
finishing products 324–30 180–1
four way junctions
Aquamix 325 Lining Systems To Upgrade Internal
C Stud Partition Systems 59
Aquastrip 327 Walls 182–3
Twin Frame Partition Systems 103
Corner 90º External 328 Mass Barrier Ceilings 136
frame components 308–20
Cove 90 329 Megadeco Partition Systems 28–31
Acoustic Floor Clip 317
Cove 120 329 Roof Lining Systems 188–9
Acoustic Homespan C Studs 308
Cove Adhesive 329 Separating Floor Systems 128–30
Acoustic Homespan Starter Studs
Deco Filler 325 Shaftwall Stairwell Systems 248
308
Deco Joint Cement 326 Shaftwall Systems 244–7
Acoustic Stud 309
Deco Machine 326 Standard Board Partition Systems
Acoustic V Brace 316
Drywall Screw heads 335 41–2
Acoustic V Brace 90º 316
Drywall Sealer 328 Structural Frame Partition Systems
C Studs 308
Duo Bead 328 45
CB Clip 316
Easy Finish Xtra 324 Suspended MF Ceiling Systems to
Protect Structure 135 Ceiling Channel 311
Edging Bead 328
Suspended MF Ceiling Systems to CH Stud 314
Flex Tape 327
Timber Floors 133–4 Connecting Clip 312
Intumescent Acoustic Sealant 330
Timber Partition Systems 47–9 Dryliner Channel 312
Joint Cement Xtra 324
Universal Board Partition Systems 32 Dryliner Channel Connector 314
Joint Filler Xtra 324
Masonry Robust Detail Systems 46 Dryliner Track 313
Joint Tape 327
Fire Protection profiles 333 E Stud 315
Patching Tape 327
Edge Channel 311
Smartmix Xtra 325
Fixing Channel 319
Socket Pads 330
Flat Strap 319
Universal Sealer 328
Flex Track Deep Flange 310
INDEX
347
INTRODUCTION
INTRODUCTION
Heavy Gauge Primary Channel 311
I Stud 309 H J
head deflection J Track 315, 333
Insulation Hold 320
C Stud Partition Systems 61–2 Joint Cement Xtra 324
J Track 315
PARTITIONS
Twin Frame Partition Systems 105–6 joint compounds 324–6
Metal Angle 90° 319
health and safety 341 Joint Filler Xtra 324
Movement Control Joint 320
healthcare projects 5 joint reinforcement see horizontal joint
Phonissimo Acoustic Hanger 317
Heavy Gauge Primary Channel 311, 333 reinforcement
Phonistar Acoustic Hanger 317
height see ceiling height change; Joint Tape 327
Primary Channel 311
maximum height jointing systems see taping and jointing
LININGS
Acoustic Stud Partition Systems 75
I Stud 309, 332 Shallow Wall Lining Systems 213
C Stud Partition Systems 53–4
impact sound insulation Suspended MF Ceiling Systems 145
Direct-to-Timber Ceiling Systems 165
Acoustic Floor Systems 137 Timber Partition Systems 118
Dryliner Ceiling Systems 157
Ceiling Systems to Timber Floors 126 Twin Frame Partition Systems 103–4
Dryliner Lining Systems 220–1
Dryliner Ceiling Systems to Concrete
Encasement Systems 271–2
Soffit 127
Independent Wall Lining Systems 230
FIRE PROTECTION
Engineered Joist Systems 122
Pregybel MF Ceiling Systems 151
Mass Barrier Ceilings 136
Resilient Bar Partition Systems 91
Separating Floor Systems 128–30
Shaftwall Systems 258–9
Suspended MF Ceiling Systems to
Shallow Wall Lining Systems 211–12 Protect Structure 135
Suspended MF Ceiling Systems 141–2 Suspended MF Ceiling Systems to
Timber Partition Systems 113–14 Timber Floors 133–4
Twin Frame Partition Systems 97–9 Independent Wall Lining Systems
226–34
insulation
G acoustic/sound 17
GTEC 3 fire 16
GTEC Lifetime System Warranty 3 thermal 19
FINISHING
INDEX
L Walls 187
Lining Systems To Upgrade Internal N
LaDura Partition Systems 22–5 Walls 183 Nailable Plug 323
LaDura Board 11, 302 Megadeco Partition Systems 28–31
LaDura pattress 67–8, 69
O
Pregybel Independent Lining Systems
Lafarge Plasterboard see Siniat 190–1
lengths Shaftwall Stairwell Systems 248 openings
Board 294–307 Shaftwall Systems 244–7 Acoustic Homespan Partition
Frame 308–20 Standard Board Partition Systems Systems 85
life cycle approach 337 41–2 Acoustic Stud Partition Systems 77
light steel framing systems (SFS) see Structural Frame Partition Systems C Stud Partition Systems 57–8
SFS junctions 45 Direct Bond Lining Systems 199
lining depth change 224 Timber Partition Systems 47–9 Dryliner Lining Systems 222
lining systems 179–241 Universal Board Partition Systems 32 Independent Wall Lining Systems 232
Contour Lining Systems 202–6 Masonry Robust Detail Systems 46 Resilient Bar Partition Systems 92
Direct Bond Lining Systems 192–201 Megadeco 11, 301 Shaftwall Systems 261
Dryliner Lining Systems 216–24 Megadeco Partition Systems 28–31 Shallow Wall Lining Systems 213
Independent Wall Lining Systems Metal Angle 90° 319, 332 Suspended MF Ceiling Systems 144
226–34 metal bead 328 Timber Partition Systems 117
Lining Systems To Framed External minimum thickness Twin Frame Partition Systems 102
Walls 187 Acoustic Floor Systems 137 over-height boarding
Lining Systems To New External Walls Ceiling Systems to Timber Floors 126 C Stud Partition Systems 56
180
Dryliner Ceiling Systems to Concrete Dryliner Lining Systems 221
Lining Systems To Thermally Upgrade Soffit 127 Independent Wall Lining Systems 231
External Walls 184–6
Engineered Joist Systems 122 Timber Partition Systems 115–16, 117
Lining Systems To Upgrade Internal
Lining Systems To Framed External Twin Frame Partition Systems 101
Walls 182–3
Walls 187
Pregybel Independent Lining Systems
Lining Systems To New External Walls
P
190–1, 236–41
180–1
Roof Lining Systems 188–9
Lining Systems To Thermally Upgrade
Shallow Wall Lining Systems 208–15 partition systems 21–119
External Walls 184–6
Acoustic Homespan Partition
Lining Systems To Upgrade Internal
Systems 43, 80–6
Walls 182–3
M Pregybel MF Ceiling Systems 131–2
Acoustic Stud Partition Systems 72–8
Aqua Board Partition Systems 26–7
manual handling 341 Separating Floor Systems 128–30
C Stud Partition Systems 50–71
Masonry Robust Detail Systems 46 Suspended MF Ceiling Systems to
dB Board Partition Systems 33–7
masonry substrates 196, 211 Timber Floors 133–4
E Board Partition Systems 44
masonry wall junctions mixed board systems 12
Fire Board Partition Systems 38–40
C Stud Partition Systems 59–60 Moisture Board 297
LaDura Partition Systems 22–5
Encasement Systems 274 moisture resistant board see Aqua;
Megadeco Partition Systems 28–31
Resilient Bar Partition Systems 93 LaDura; Moisture
Resilient Bar Partition Systems 88–93
Twin Frame Partition Systems 104 Movement Control Joint 320, 332
Standard Board Partition Systems 41–2
Mass Barrier Ceilings 136 movement control joints
Structural Frame Partition Systems 45
mass to height/span ratio 18 C Stud Partition Systems 56
Timber Partition Systems 47–9,
maximum height 18 Contour Lining System 206
110–19
Acoustic Homespan Partition Direct Bond Lining Systems 198
Twin Frame Partition Systems 94–108
Systems 43 Dryliner Ceiling Systems 159
Universal Board Partition Systems 32
Aqua Board Partition Systems 26–7 Dryliner Lining Systems 222
Masonry Robust Detail Systems 46
dB Board Partition Systems 33–7 Independent Wall Lining Systems 232
E Board Partition Systems 44 Shaftwall Systems 260
Fire Board Partition Systems 38–40 Shallow Wall Lining Systems 213
Horizontal Shaftwall Systems 249 Suspended MF Ceiling Systems 144
LaDura Partition Systems 22–5 Twin Frame Partition Systems 101
Lining Systems To Framed External
INDEX
349
INTRODUCTION
INTRODUCTION
parge coat see E Coat
Patching Tape 327 S fire resistant encasement 250–3,
271–5
safe handing 341 Fire Core Board 299
penetrations
school buildings see educational SFS junctions 104
C Stud Partition Systems 65–6
PARTITIONS
projects
Shaftwall Systems 264–5 shaftwall junction 263
screws
Twin Frame Partition Systems 106 Strap Hanger 318
Drywall Screws 322–3
perforated board see Pregybel strength duty 18
selection guide 334–5
performance tables see system Acoustic Homespan Partition
sealant Systems 43
performance
Intumescent Acoustic Sealant 330 Aqua Board Partition Systems 26–7
Phonissimo Acoustic Hanger 317
LININGS
pull-out loads 69 Twin Frame Partition Systems 106 Stud and Track profiles 332
purlins, head deflection, C Stud Socket Pads 330 stud splices
Partition Systems 62–3, 64 Soffit Cleat 312 Acoustic Stud Partition Systems 75
sound absorption see acoustic C Stud Partition Systems 53
performance
R
Twin Frame Partition Systems 99
sound insulation see acoustic
Shaftwall Systems 258
FIRE PROTECTION
recycling of waste 337–8 performance
substrates (see also masonry
refurbishment projects (sustainability) splayed corners
substrates)
340 C Stud Partition Systems 59
Contour Lining System 205
render, E-coat 321 Twin Frame Partition Systems 103
Direct Bond Lining Systems 196
Render Board 303 SR Bracket 313, 333
Dryliner Lining Systems 219
renovating walls, Contour Lining Staggered Stud Clip 318
Shallow Wall Lining Systems 211
Systems 202–6 stairwell systems, Shaftwall Systems
Taping and Jointing Systems 281
residential projects 9 265
Suspended Ceiling profiles 333
Resilient Bar 315, 332 Standard Board 294
Suspended MF Ceiling Systems 138–47
Resilient Bar Partition Systems 88–93 Standard Board Partition Systems 41–2
Suspended MF Ceiling Systems to
Resilient Tape 318 standards 342–3 (see also British
Protect Structure 135
Responsible Sourcing of Construction Standards)
Suspended MF Ceiling Systems to
Products (BES6001) 339 Board 294–307
FINISHING
INTRODUCTION
INTRODUCTION
INDEX
T V
tape on bead 328 Vapour Base Board 296
taping and jointing systems 278–83, Vapour Board 296
PARTITIONS
324–7 V-brace fixing 99
telescopic deflection head assembly
63–4
test methods 343
Thermal EPS Board 303
W
Wall Lining Adhesive 321
Thermal K Board 305 wall linings see linings
LININGS
Timber Partition Systems 118 Direct Bond Lining Systems 199
Twin Frame Partition Systems 103–4 Dryliner Lining Systems 222
Twin Frame Partition Systems 94–108 Independent Wall Lining Systems 232
Shallow Wall Lining Systems 213
U
X
FIRE PROTECTION
U Track 309, 332
U Track Deep Flange 310, 332 XR Bracket 313, 333
U Track Extra Deep Flange 310, 332
universal beams see beams
Universal Board 302
Universal Board Partition Systems 32
Universal Bonding Compound 321
universal columns see columns
Universal Sealer 328 PENARTH LEARNING
U-values 19
COMMUNITY
Lining Systems To Framed External
PENARTH, WALES, UK
Walls 187
Lining Systems To New External Walls Sector: Education
FINISHING
180–1 Project Value: £48 million
Lining Systems To Thermally Upgrade Client: Vale of Glamorgan Council
External Walls 184–6
Architect: HLM
Lining Systems To Upgrade Internal
Walls 183
Main Contractor: Bouygues UK
Roof Lining Systems 188–9 Sub Contractor: M & P Contractors
Wales Ltd / Neath Dry Lining
REFERENCE
Siniat Innovations: Megadeco, Pregybel
i
350 INDEX
INTRODUCTION
INTRODUCTION
INDEX
T V
tape on bead 328 Vapour Base Board 296
taping and jointing systems 278–83, Vapour Board 296
PARTITIONS
324–7 V-brace fixing 99
telescopic deflection head assembly
63–4
test methods 343
Thermal EPS Board 303
W
Wall Lining Adhesive 321
Thermal K Board 305 wall linings see linings
LININGS
Timber Partition Systems 118 Direct Bond Lining Systems 199
Twin Frame Partition Systems 103–4 Dryliner Lining Systems 222
Twin Frame Partition Systems 94–108 Independent Wall Lining Systems 232
Shallow Wall Lining Systems 213
U
X
FIRE PROTECTION
U Track 309, 332
U Track Deep Flange 310, 332 XR Bracket 313, 333
U Track Extra Deep Flange 310, 332
universal beams see beams
Universal Board 302
Universal Board Partition Systems 32
Universal Bonding Compound 321
universal columns see columns
Universal Sealer 328 PENARTH LEARNING
U-values 19
COMMUNITY
Lining Systems To Framed External
PENARTH, WALES, UK
Walls 187
Lining Systems To New External Walls Sector: Education
FINISHING
180–1 Project Value: £48 million
Lining Systems To Thermally Upgrade Client: Vale of Glamorgan Council
External Walls 184–6
Architect: HLM
Lining Systems To Upgrade Internal
Walls 183
Main Contractor: Bouygues UK
Roof Lining Systems 188–9 Sub Contractor: M & P Contractors
Wales Ltd / Neath Dry Lining
REFERENCE
Siniat Innovations: Megadeco, Pregybel
i
TECHNICAL SERVICES
DRYWALL
GB ORDERLINE March 2017
For placing orders, delivery enquiries
and local stockists etc.
0800 373636
MANUAL
01275 379037
orderline@etexbp.co.uk
IRELAND ORDERLINE
For placing orders, delivery enquiries
PLASTERBOARD SYSTEMS FOR
and local stockists etc.
+353 (0) 16203114
PARTITIONS, CEILINGS AND
01275 379037 WALL LININGS
irelandorders@etexbp.com
LITERATURELINE
For Siniat literature.
01275 377582
literatureline@siniat.co.uk
WALL LININGS
PARTITIONS, CEILINGS AND
PLASTERBOARD SYSTEMS FOR
Etex Building Performance Limited
Marsh Lane, Easton-in-Gordano, Bristol, BS20 0NE
+44 (0)1275 377773 www.siniat.co.uk
© 2017 Etex Building Performance Limited