You are on page 1of 2

Lighting Systems

XML LED Classifications


• Class I, Division 1, Groups C & D

Explosionproof linear • Class I, Division 2, Groups C & D


• UL 844 Hazardous Locations

LED lighting • UL 924 Emergency Lighting


• UL 1598A Marine Outside Type
• UL 1598 Wet Locations
• UL 8750 LED Safety
• CSA C22.2 No. 250.0–08
• CSA C22.2 No. 137–M1981
• NEMA 4X, 7CD
• ABS Type Approved
• IP66
• Paint Spray Booth
Key Features • Emergency Battery Backup
• Low-profile, lightweight design • -40°C to 65°C Ambient Temperature
• Convenient wiring access through screw-cap cover with toolless, • ABS Type Approval
cage clamp terminal block • Tested to LM79 and LM80
• Self-contained emergency battery backup, no additional junction box required • DLC Listed
• Heavy-duty, 7/16" thick die-cast safety cable attachment points
• Replaceable LED circuit boards and drivers with quick disconnects
• Adjustable mounting bracket with 90 degree range of motion and Standard Materials
13 locking positions* Body: A360 Aluminum (less than .4%
* Not included, must be ordered seperately. Please see options section. copper content) with baked-on gray epoxy
finish
Gaskets: One-piece neoprene
Lens: Tempered glass
Additional Features
Hardware: Stainless steel
• Supplemental 10kV surge protection
• Central safety cable attachment points for increased safety/reduced range of
motion
• Feed-through and pendant mount capable
• Diffused lens option
• 5-year warranty

AZZ Lighting Systems | 8500 Hansen Road, Houston, TX 77075 | (713) 943-0340 | azz.com/rigalite
Lighting Systems

Certification Guide
Class Class II,
Lumens I, Div. 1. Supply Wire
Operating Total Ambient Simultaneous
Model Length Wattage per CRI CCT Div. 1, Group Suitable
Voltage Lumens Temperature Presence
Watt Group E, F, G Temperature, °C
C&D Class III
120V - 277V
XML04LC2U 2 ft 33W 3654 109.9 83 4096 -40°C < Tamb < 55°C T6 Pending 90°C
50/60 Hz
XML04LC2N 2 ft 37W 347V/480V 60 Hz 3654 98.8 83 4096 -40°C < Tamb < 55°C T6 Pending 105°C
120V - 277V
XML07LC4U 4 ft 69W 7743 112.9 82 4107 -35°C < Tamb < 60°C T6 Pending 90°C
50/60 Hz
XML07LC4N 4 ft 76W 347V/480V 60 Hz 7743 101.9 82 4107 -35°C < Tamb < 60°C T6 Pending 105°C
120V - 277V
XML04LD2U 2 ft 33W 2815 84.7 83 4071 -40°C < Tamb < 55°C T6 Pending 90°C
50/60 Hz
XML04LD2N 2 ft 37W 347V/480V 60 Hz 2815 76.1 83 4071 -40°C < Tamb < 55°C T6 Pending 105°C
120V - 277V
XML07LD4U 4 ft 69W 5836 85.2 82 4183 -35°C < Tamb < 60°C T6 Pending 90°C
50/60 Hz
XML07LD4N 4 ft 76W 347V/480V 60 Hz 5836 76.8 82 4183 -35°C < Tamb < 60°C T6 Pending 105°C

XML - 07 - L - C - 4 - U - XX
1 2 3 4 5 6 7
1 4 7
SERIES LENS OPTIONS
XML LED1 C = Clear RIG = Mounting Bracket & (2) Safety Cables
D = Diffused MB = Mounting Bracket Ceiling or Wall
HA = High Ambient 65°C Rated (4 ft.
2
Model Only)
LAMP WATTAGE 5 EM = Emergency Battery Backup (Not
07 = 75 Watt LED (4 ft.) NOMINAL FIXTURE LENGTH Available with 347/480V)2
04 = 40 Watt LED (2 ft.) 2 = 2 Foot FB = Fuse Block3
4 = 4 Foot PB = Push to Test Switch for EM Option
Only
3 6 30 = 3000K (CCT)
LAMP TYPE 35 = 3500K (CCT)
VOLTAGE/FREQUENCY
L = LED 50 = 5000K (CCT)
U = 120 - 277V 50/60 HZ
(4000K CCT) N = 347/480V 60 HZ
A = 120V 60 HZ
B = 220 - 240V 50/60 HZ
C = 277V 60 HZ
1 Mounting hardware not included. See options for mounting selections.
2 4kV surge protection. Supplemental 10kV surge protection not available on EM models.
3 Specify voltage when option FB is needed. When option FB is selected, one fuse is provided for 120 and 277V. Two fuses are provided for 220-240V and 480V. Fuse
option not available for marine listed fixtures, or for fixtures listed for use in Canada.
Part numbering logic is for explaining part number structure only. Not all combinations are possible; consult factory for catalog numbers not listed on chart.