You are on page 1of 4
MEDIZAQ IMAGING Co. A STEP AHEAD TOWARDS IMAGING. QUOTE TO Insaat Hospital auote no. icalHvkP20220001 Yaar Mohammad Khan QUOTE © oare Quetta Town, Karachi, Pakistan Sees 7 © vauio uN. Ww Four ()wooks om cvolaon date Item Description Sat Quantity ar) GE LIGHTSPEED ULTRASCT SCANNER (UsedPre--USD69,000, 1 USD 69,000 Owned) [ESSERE {80% Down payment 10% On system antval at Pon > 10% After systom instalation Disclaimer: Above information isnot an inv fescived above, Meaizag will NOT be responsi applicable taxes wil be includes 1nd only an estimate of services/goods lor any government ap n official Mecizag inv taxes. Al ‘Should you have any enquiies conceming this quote, ploase do not hesitate to Please o Yim your acceptance of this quot by signing this document Thank you for your busines: USD 69,000.00 PEL) Nine Thousand Datars SUBJECT: QUOTATION & SPECIFICATIONS FOR GE LIGHTSPEED ULTRA 8 CT Dear Sir, As per your inquiry, we are pleased to offer you the GE LightSpeed Ultra 8 CT Scanner Machine(s) available in excellent condition and at a very reasonable price. A cutting-edge competitor in the 8 Slice CT market. Brief specifications of the system and our Terms & Conditions are as follows: SYSTEM DESCRIPTION “The GE Lightspeed Ultra 8 Slice CT System is a third generation multi-slice helical CT Scanner. It features a 53-kW generator, 6.3 MHU tube, and a fast gantry rotation time of 0.5 seconds. Capable of imaging 8 slices per rotation with widths of 8 x 125 mm and 8 x 2.5 mm as well as 4 slice widths of4.x 1.25 mm to 4 x 5 mm slices. Other sizes are available as well.” (SEI ‘Ask one of our experienced representatives for additional details of this system's features. SYSTEM SPECIFICATIONS MODEL, X-RAY TUBE ANODE Heat storage, hu (X-ray tube anode) Heat dissipation rate, hu/min (X-RAY TUBE) ‘Tube focal spot, mm (X-ray tube anode) POWER NEEDED ‘Type (CONFIGURATION) # of slices (X-ray tube anode) Image storage Hd capacity, gb (IMAGE STORAGE) FLOOR SPACE NEEDED Size, m2 (FLOOR SPACE NEEDED) SCORING OF CORONARY ARTERY CALCIFICATION (IMAGE STORAGE) DICOM 3.0 COMPATIBLE (POWER NEEDED, VAC) DISPLAY MONITOR Matrixes, pixels (DISPLAY) Range of ct numbers (DISPLAY) Image enlarging scale (DISPLAY) GENERATOR (Output, kw (X-RAY GENERATORS) LightSpeed Ultra 8 8,0,000 1782000, 0.7x08,0.9x09 460/480 VAC nominal, 50/60 Hz, 3- phase delta or Wye Mutistice 8 146 28 minimum Optional Yes 20" (2), opt flat 4280 x 1024 -1,02410 43,071 Up to 8x 100 Ma range (IMAGING SYSTEM) FDA CLEARANCE (Interference compensation) CE MARK (MDD) (Interference compensation) High-contrast spatial resolution 0% mt, Ipicm (High-contrast spatial resolution) 50% mit, Ipicm (PERFORMANCE) Slice sensitivity profile Low-contrast resol (lice sensitivity profi Noise, % at AgAtAa25 mGy (2.5 rads) (Slice sensitivity profile) X-RAY TUBE Heat storage, MHU (X-RAY TUBE) Heat dissipation rate, kHU/min (X-RAY TUBE) ‘Tube cooling (X-ray tube anode) ‘Tube focal spots, mm (X-RAY TUBE) Expected tube lite, scan sec (& calendar) (X-RAY TUBE) Maximum ma (X-ray tube anode) Maximum scan time at maximum ma, sec (X-ray tube anode) IMAGE PROCESSING (MAXIMUM DISPLAY) Standard or optional (IMAGE PROCESSING) Recommended post-processing workstation (IMAGE PROCESSING) Remote access to clinical applications (IMAGE PROCESSING) Dicom 3d image export (IMAGE PROCESSING) RECOMMENDED ROOM SIZE, mA? (IMAGE PROCESSING) RADIATION DOSE IMAGE RECONSTRUCTION Cpu (NETWORK/DATABASE) Scan fovs, cm (|MAGE PROCESSING) Reconstruction matrices (IMAGE RECONSTRUCTION) No. of online images (IMAGE STORAGE) ‘Archive (IMAGE STORAGE) CLINICAL APPLICATIONS AND FUNCTIONALITY ‘Quantification (CLINICAL APPLICATIONS & FUNCTIONALITY) DICOM (GANTRY) mm at % at A¢AteAn20 mGy (2 rads) CT image storage SCU/SCP (Range of movement) Modality worklist SCU (Range of movement), Query/Retrieve SCU and SCP (Range of movement) Storage commitment SCU (Range of movement) Modality performed procedure step SCU (Range of movement) HE profiles supported (Range of movement) DETECTOR (SCATTERED LIGHT) Total detector width, z-axis, mm (DETECTOR) Reconstructed slice width options, mm (GANTRY) Standard Rotation times, sec, 360A" (DETECTOR) MARKETING REGION (Interference compensation) 10 Yes Yes 0.35 mm 18.4, 1962 10.2) 196-2 5 mm at 0.9% at 1.3 mGy, 8° CATPHAN 0.82% at 2.85 rads 8 1782 Oivair 0.7 x06,09x09 ‘See tube warranty 800 5 Optional AW. Optional Yes 455 minimum Open architecture! LINUX 25, 50. 512x512 250,000 (512 x 512) 2.3. GB MOD, DICOM3.0 Yes ‘As defined in DICOM Conformance Statement Yes Yes Yes Yes Yes Yes 40 01625, 4.25, 25, 3.75, 5,75, 10 0.35, 0.37, 0.4, 0.42, 0.45, 0.47, 05, 068, 0.7, 018, 09, 1, 2,3,4 Worldwide Key Highlights: - 6.3 MHU Tube - Solid State Detectors - High Performance DAS - Operators Console - 53KW Generator - 10 to 440 MA - Subsecond Scan Time - Dual Monitors - Helical Tilt Variviewer - 70 CM Gantry Aperture - Magnetic Optical Disk Storage - +/- 30 Degree Gantry Tit, 120 Second Helical Applications: S-slice, General, Abdominal, Angiography, Brain, Dental, Pediatrics, Perfusion, 9D, ete, TOTAL PRICE: USD 69,000.00 “NOTE: Applicable Government Taxes Not Included. [Sixty-Nine Thousand Only} TERMS & CONDITIONS VALIDITY | Our quotation is valid for 4 weeks. MODE OF PAYMENT | 80% Deposit at the time of order confirmation. 10% On shipment arrival at Karachi Port 10% After installation & commissioning of the system WARRANTY | The offered price comes with 6-Month Warranty with Parts including Tube. However, Tube(s) Work involved aration. Incl Conditioning & ul owners. d up to date inaccurate and/or outdated. Looking forward to receive your val you of our best cooperation and service. Thank you. Sincerely, Umar Bami Chief Operating Officer Medizaq Imaging Co. www.medizag.com

You might also like