3 Phase, 415V, 50 Hz Power connection shall be provided by client and connected to the Control
panel located inside the Container.
The valves in the reject line will be replaced with New Manual Duplex stainless steel vaives.
he entire pipe works from the RO High Pressure pump discharge should be modified to Duplex
Stainless stee! materials of Pipes and fitings.
The RO System Design should modify to operate for a period of 22 hours a day.
The RO plant is designed at the Average flux of less than 18 LMH.
The RO plant should be designed ata recovery of 40%.
Layout and required technical support for pipe line works other than OWATCO scope
800 and material specification for Pipe line works other than OWATCO scope.
If Exova required, PPE wili be given on chargeable basis.
OWATCO should make sure that final purified water shall comply éll parameters as mentioned in
SP-1232 — HSE Specification — Public Health 3.4APPENDIX D - D, inking Water Standards
(Oman STDS 08/2006) and should comply below mentioned paramevers,
Description Unit Guideline ‘|
| Conductivity MicroSiemens/em Lessthan800
TotalDissolvedSolids Me/i Lessthansoo
pH Mest 6.5to7.5
350m3perdayasROProdu
Flow M3perday ctwater(22hrs.ofoperati
L on) stl
CWATCO should design and commission the RO plant as it should work with TDS of 26000
mg/L.
OWATO should supply chemicals for one month operation after commissioning.