Professional Documents
Culture Documents
CME Lab23
CME Lab23
1. Objective:
The objective was to recreate the diffusion of nickel in a Fe-Cr-Ni system at 1200 K.Through adjusting the
compositions and materials, we aimed to observe and analyze the process of nickel content diffusion over time.
This would help us gain insights into how materials behave and determine the timescale required for achieving
homogeneity.
2. Introduction:
The Diffusion Module (DICTRA) is, as the name implies, used for diffusion calculations. In this exam-
ple of a Fe-Cr-Ni diffusion couple with different nickel contents, we will calculate diffusion using dictra and
thermocalc.[1][2]
The diffusion couple consists of two foils of different materials in the same phase, Austenite (FCC), but with
different compositions. The two foils are joined together and kept at an elevated temperature of 1200 K.
[1][2]
The simulation is set up as a single region calculation with a step in the composition profile where the different
materials meet. The material on the left side is Fe-18Cr-8Ni and the material on the right side is Fe-18Cr-26Ni.
The thickness of each of the two foils is 50 micrometers. The Figure1 shows an illustration of the two foils
where the Ni content is indicated with a blue dotted line. [1][2]
Figure 1
Page 1 of 9
Computational Materials Engineering Lab Lab Activity 05
3. Procedure:
3.1. Add the Necessary Nodes and Define the Initial System:
On the home screen of Thermo-Calc, was clicked the Diffusion template to add the necessary activity nodes.
As shown in the Figure2.[1][2]
Figure 2
In System Definer, databases and elements were chosen for diffusion simulation. In this case:
• The FEDEMO and MFEDEMO databases (Demo: Steels and Fe-alloys database package) were uti-
lized.
• The elements Fe, Cr, and Ni were selected from the periodic table.[1][2]
As shown in the figure3
Figure 3
Page 2 of 9
Computational Materials Engineering Lab Lab Activity 05
Diffusion simulations could be time-consuming. To optimize, in the System Definer, was selecting only essen-
tial phases in the Phases and Phase Constitution tab.[1][2]
In this case:
• At a temperature of 1200 K, we calculated, and the material was fully austenitic (only FCC phase) at that
temperature. Therefore,all phases except FCC A1 were deselected
Figure 4
The composition unit was changed to mass percent, and the length unit was changed to micrometer. As shown
in the Figure5.[1][2]
Figure 5
Page 3 of 9
Computational Materials Engineering Lab Lab Activity 05
Since we wanted to calculate the diffusion in two foils, which had planar geometry, Planar geometry was
selected.[1][2]
As shown in the figure??.
Figure 6
For diffusion simulations, at least one region needed to be defined containing at least one phase. For some cal-
culations, you might have wanted to create several regions, for example, moving phase boundary simulations.
Naming the regions was optional but could be useful when having more than one region. To add a new region,
the plus sign next to Region was clicked. In this example, a second region was not added. As shown in the
figure7.[1][2]
Figure 7
The region was named Austenite, and the width was set to 100 µm (1e-4 m) with 100 points. The type of
grid was changed to Double geometric, and the lower ratio was set to 0.95, while the upper ratio was set to
1.05. This was done to have a high number of grid points in the middle of the geometry. A preview of the grid
was shown in red right above the region, as seen in the Figure8 below.[1][2]
Page 4 of 9
Computational Materials Engineering Lab Lab Activity 05
Figure 8
We simulated how the Ni content varied between the two metal sheets with different Ni concentrations.[1][2]
• Fe was selected as the dependent component, and the Cr content was set to be constant at 18 wt%.
• For Component Ni, Step was selected, and the composition was set from 8 to 26 wt% at 50 µm (5e-5 m).
Figure 9
This created a composition profile simulating two materials with different nickel compositions: one with
8 wt% nickel and another with 26 wt% nickel. The composition profile was displayed in the Visualizations
window. As shown in the figure10.[1][2]
Page 5 of 9
Computational Materials Engineering Lab Lab Activity 05
Figure 10
For this calculation, the default setting, which is a Closed system, was used.[1][2] As shown in the Figure11.
Figure 11
For this calculation, Isothermal was selected, and the temperature was set to 1200 K. The simulation time was
set to 1e10 seconds. As shown in the Figure11.[1][2]
Page 6 of 9
Computational Materials Engineering Lab Lab Activity 05
Figure 12
In DICTRA, set visualization time in Plot and Table Renderers; crucial it’s within simulation time for
calculated values. Use seconds, minutes, hours, or days.
• The following times were added: 1.0, 60.0 (1 hr), 1440.0 (1 day), 10080.0 (1 week), 43800 (1 month),
525600 (1 year), 1051200 (2 years), 2629800 (5 years).
Figure 13
Click Perform at the bottom of the Plot Renderer window and see that the event log starts populating. When
the calculation is finished, the result will show in the Visualizations window. As shown in the figure 14.
Page 7 of 9
Computational Materials Engineering Lab Lab Activity 05
Figure 14
Figure 15
When the diffusion couple is held at a higher temperature (1200K) for a longer period of time, the nickel
diffuses from the nickel-rich to the nickel-poor material, resulting in a composition gradient on both sides. It
is also demonstrated that it takes around 5 years for the diffusion pair to achieve homogeneous nickel content,
which means that the nickel content in both materials is the same.
5. Conclusion:
During the simulation it can be observed that at a temperature of 1200K, over a period of five years nickel
gradually moves from a material that’s rich in nickel to one that’s poor in nickel. This process leads to an
Page 8 of 9
Computational Materials Engineering Lab Lab Activity 05
equalization of the composition gradient resulting in homogeneity. When the duration is extended the diffusion
effect becomes more prominent which is crucial, for comprehending how materials behave in applications.
References
[1] ”Diffusion Module (DICTRA) Guide.” Thermo-Calc Software, [Accessed on 23 Sep,2023], https://
thermocalc.com/support/getting-started-guides/diffusion-module-dictra-guide/.
Page 9 of 9