BAO CAO HIEU CHUAN THIET B] INSTRUMENT CALIBRATION REPORT I. Théng tin thiét bj / Equipment Information Page 1/1 ‘Thiét bi/ Instrument ‘Temperature Humidity Logger 4 ‘Thang do ciia thiét bi/ | -40°C - 70°C Ma sé/ 1D AU29 Instrument range 0- 100%RH Ngay higu chudin/ » ‘Thang sit dyng/ Using | 0°C - 60°C Calibration date 1.03. range 50- 80%RH _| Don vi higu chudn/ ‘Thang higu chudn/ 30°C ~ 65°C | Calibration site 7 Techmaster | Calibration range 10%RH — 95%6RH I, Th6ng tin thiét bj chudn/ Information of standard equipment ‘Ten thiét bj chuén/ Standard equipment name Higu Iwe/ Valid uncit Standard Number Manufacturer Model TEV-TEO079 VAISALA MITO 08/Nov/2022 TEV-TE0054 — ESPEC SH-642 251Jun/2022 TEV-TEO080___ VAISALA HMP77B 08/Nov/2022 IL. —N@i dung higu chuan/ Calibration content: Attachment: Certificate Number TSG-0-230055-R1 IV. Két qua higu chudin Result of Calibration w/Dat/ Pass / —aKhdng dat / Not Pass V. Higu lye/ Valid until: 11/Mar/2023 (pa kiém tral Content verified Ngay/ Date: 21.04.22 Negiy/ Date: 24 CF QZ Negay/ Date: $2 - Ol Ngubdi bao co/ Compiled by: Nguoi kiém tra/ Reviewed by: Negudi duyét/ Approved by: Abu Ate Noun Lf Bio Doyen {ran Pham Thanh Théo |_ Ten Haj 7hu Yer ‘SOP-LA-G001-FORMO5/02 GlobalLeaderin peste quan soranard ‘Service License NY OR2ES ot ng SaaS, em os, SS “cuaron sonson hy, ran “dahaiao nt Aten awn Eanes TIFICATE OF CALIBRATION Certificate Number TSG-0-230055-R1 IN A ‘Customer: ‘CONG TY TNHH ROHTO - MENTHOLATUM (VIET NAM) 16 VSIP, Duong s6 5, Khu Cong Nghigp Vigt Nam-Singapore, ‘Thanh Phé Thugn An, Tinh Binh Duong, Viét Nam. Manufacturer: EXTECH Calibrated By: ‘Tran Anh Vu Description: Humidity/Temperature Datalogger Calibration Date: 11/Mar/2022 Model: RHT20 Recommended Due: _11/Mar/2023 Size /Range: _ -40~70)°C/0.1°C ; (0~100)%RH/0.1%RH Calibration Location: In-Laboratory Serial Number: 161206532 Condition Received: In Tolerance Asset Number: AU29. Condition Returned: In Tolerance P.O. Number: TEV-ROHTO 220301 Procedure: ‘TEV-TD002-21 Accessories: Environme: ‘This cots that tho above instrament was calibrated in compiance with tne Odibyaton Systems Requiemnt of SOME 170252017, ANSIAESL 2540.7 ith referenced procedures. Standards used to perfor this calloayin gr Wacoable to I uns; ther source of racoobity deive.i9h's National Metro gh of HIST, CENAM, NPL, DIN, VM... bom natura phys constant, consensus standards or derived by the rai peo Calibrations. Estinetod statomonts of Uncertainty are determined as required witha dso the coresponds 10 probably of approximately 98% jke2), no sampling plan or other process was used {or this catioration, the results reported herein Spy ‘nly to the callration ofthe tem describe above.A\/aibaions are performed to manufactuer’s specications, ‘less otherwise noted. Customer has been contacted concerning re-cetiiation terval ai documentation has boon received and ison fl. This fm shat ‘ot be reproduced, exceptin ful, without the exprossed writen consent of Techmaelé Electronics. the manufacturer has a specie tolerate for his itom, ‘hen the calibration eu wih our uncertainty value ated, are compared to thi lenge, and the combined value Calibration Accuracy: Base on Manufacturer's Spestigations! Customer's Specifications or Decision Roles fr complidncrsalements of TEV Laboratory. Remark: Standards Utilized ‘Standard Number Manufacturer Model # Due Date Report Number Traceability TEV- TE00S4 ESPEG SH-642 2s/5un/2022 ‘TSG-0-188877 TEY. TEV- TE0079 VAISALA I70 (O8INov/2022 ‘TSG-0-208454 ats ‘TEV- E0080 VAISALA HMP77B O8/Nov/2022 ‘TSG-0-208455 ATS ‘Quality Assurance: (am bio chat boone) Page tof ‘Technical Manager: (Gi st ko. thug) sued on: 15/04/2022 at 246 nt o Reuyga van Tiga Le Nfuyén Va Nehiép ‘540, VOuthioaten VERev 08 TECHMASTER Sesaaaal eles GlobalLeaderin Tost Equipment Solutions Service License No : DK283, 6915 Lio it Cun Sect. An Kas “ha Due Cy Ho Ci Min iy Vista | el (025) 6206 255 Fax: (026) 6266 133 -S muntachmasarcomn- in@lacrateronion CALIBRATION REPORT Report Number: TSG-0-230055-R1 ‘Manufacturer: EXTECH ‘Model: RHT20 Asset No. / Serial No.” AU29/ 161206532 1. Temperature Measurement Accuracy Test ae] A Expanded Tolerance Function | Standard Values | .A° | (Mf, | comoction | Rosu | yraruee, | ‘ 01 [304 [a0 [0d PASS 0.85 sit 251 1050 07} 07 03 [Pass 0.08 00 20 41°C 38 | 38 03 | PASS. 0.08; 34 5. 30°C 77 [ ott ‘03 [Pass 0.08 60 100 750°C Tap aT 03 | PASS 0.08 74.0 760 ae 200°C 407 | 197 03 | PASS. 9.98 79.0 210 25.0°C 248 | 248 02 | PASS. 0.085 23.0 27.0 239°C 236 | 296 (03 | PASS 0.08 28.9 309) 404°C 398 | 398 (03 [PASS 0.08 39.1 ant 39°C 366 | 566 03) PASS: 0.08 349 53) 539°C 596 | 596 03 [Pass 0.08 58.9 60.9 649°C a7 —| 647, 02 [Pass 0.08 629 6.9 As 6 ded Tole 1) es ] A pando olerance Function | Standard Vatues'| Jing | Lon | Correction | Result | rec tsinty Th as Ss qosmRH | v3 | 113 “0___[ PASS 0.58 68. 138 B02 %RH | 487 | #87 15] PASS 0.58 467 537, 548 %RH | 528 | 62.8 20 | PASS 0.58 298 38 oe 02 %RH | 585 | 585 :7_[ PASS 0.58 567 637 648 %RH | 629 | 629 1.9 | PASS 0.58 398 39.8 748 %RH | 729} 728 49] PASS 088 713 783 8041 %RH | 785°] 765 1.6 | PASS 058 751 a5. 4.8 %RH | 925 | 925 23 [PASS 058 308 99.8 Note: The reported uncertainty of measurement was based on a standard uncertainty multiplied by a coverage factor k = 2.00, providing a level of confidence of approximately 95 %. Explanation: TAs Found: value before adjust AS Left value after adjusted’ * Correction: The resull of @ measurement in which the instrument gave a reading is obtained by adding the correction to the reading, + MinMax: range of value that Unit Under Test must be within in pass condition Certified By Technician: Tran Anh Vu Nouyen Van Tien Page 1 of 1 '840.1/Form-03-004 Rev.01

You might also like