Page 1/1 BAO CAO HIRU CHUAN THIET BI INSTRUMENT CALIBRATION REPORT I. Théng tin thiét bj / Equipment Information ‘Thiét bif Instrument Temperature Humidity Logger 4 Thang do cia thiét b/ | -40°C - 70°C Mes 2D SUL Instrument range 0 100%RH Nagy higu chudn/ 07.06.22 ‘Thang str dung/ Using | 0°C - 60°C Calibration date range Don vj higu chuin/ Te ‘Thang higu chudn/ -30°C - 65°C Calibration site echmaster | Calibration range IL Thong tin thiét bj chudin/ Information of standard equipment ‘Tén thiét bj chuan/ Standard equipment name Higu lye! Valid untit Standard Number Manufacturer Model TEV-TE0079 VAISALA MI70 08/Nov/2022 TEV-TE0054 ESPEC SH-642 25/May/2023 | TEV-TEO080___VAISALA HMP77B, 08/Nov/2022 MIL, Ni dung higu chuan/ Calibration content: Attachment: Certificate Number TSG-0-248715 This data logger is just only use for measurement temperature purpose. So, the result of humidity calibration ism IV. Két qua higu jot applicable. chuiin Result of Calibration Higu chuain nhigt 6/ Temperature calibration Dat! Pass | 2 Khong dat / Not Pass V. Higu hye/ Valid until: 07/Sun/2023 ‘Ngay/ Date: A506 al Naud béo cio/ Compiled by: Ahad Aguydn 12 Blo Dwyen SOP-LA-G001-FORM0S/02 1 Da kiém tra/ Content verified Neiy! Date: 1.06 D Neay/ Date: 20. Of. 22 Neue 1m tra/ Reviewed by: Newdi duyét/ Approved by: Al Ae nu ¥en Tran Pham Thanh Théo a ie) SE, Glbaitgd@aN Tete quiomentSeisons finesse SConeorree Seca lone x28 me AceRepiTeD ere tear TY —=_ Th bay He Gt aa CaS a e128 6a 280 a 02 200 399 ba wegen ain ‘ERTIFICATE OF CALIBRATION Certificate Number wn Customer: CONG TY TNHH ROHTO - MENTHOLATUM (VIET NAM) 16 VSIP, Dudng $6 5, Khu Cong Nghigp Vigt Nam-Singapore, ‘Thanh Phé Thun An, Tinh Binh Duong, Vigt Nam. Manufacturer: EXTECH Calibrated By: Luong Tuan Quoe Description: _Humidity/Temperature Datalogger Calibration Date: O7/Jun/2022 Model: RHT20 Recommended Due: 07/Jun/2023 Size /Range: __(-A0~70)° C10.1°C; (0+100)%6RHV/0.1%RH Calibration Location; In-Laboratory Serial Number: 161206316 Condition Received: In Tolerance Asset Number: AU24 Condition Returned: In Tolerance P.O. Number: TEV-ROHTO 220531 Procedure: TEV-TD002-21 ‘Environment: 25°C 42°C /, ABR SIRE Accessories: This cots the the ove instumont was calratedin compliance wth the GSiyation Systems Requirement of ISOMEC 170252017 ANSUNESK: 2540.1 n accordance wit refer! procedures. Standards used to perform this calibration re traceable to SI units; their saurce of racaabilly deal iign National Metrology Institute sigh a AIST, CENAM, NPL, DIN, Vi... rom natural physi canstats, consensus standards or derived by the ratio eabations Estimated statements of 2), no sampling plan or ether procase was use \cetanty are determined as required with a dition thet comesponds toa probability of approximately 95% forthiscalbration, the results eportod heroin Sppy only tothe calibration of the tem describe above Alito are performed to manufacturer's spectcala unless othorwise noted. Customer has been contacted conceming recertification interval afd: deeuitnentation has bean received ands on te. This fir ‘not be reproduced, excepts fl, without tho expressed written consent of Techmaslo Eloclronics. the manufacturer has a specified toeraiee fr this {thon tho catbraton ut Wilh our uncertain value added, are compared othe élemnee, and the combined value. Calibration Accuracy: Base on Monufacturers Specifications! Customers Specifications or Decision Rules for conipliancestatements of TEV Laboratory, Remark: Studs Uttized ‘Due Date ‘Report Number ‘Traceability’ ‘Standard Number Manufacturer ‘Model # ‘TEV. TEOOS4 ESPEC, SH-642 25!May/2023 ‘TSG-0247571 TEV TEV- TEO079 VAISALA MI70 O8/Novi2022 ‘TSG-0-208454 ATS TEV. TEOO80, VAISALA HMP77B 8/Novi2022 ‘TSG-0-208455 ATS ‘Technical Manage (Gin sit thud Ta Nfuyén Vir Nghigp Issued on: 11/06/2022 a 9:13 AM ‘540. VOertiates VE Rov 08 ‘Qhiality Assurance: (Déim bio chat luce) age of ReuyénVan Tiga Gssiala lal eer GlobalLeaderin Test Equipment Solutions ‘Service License No : DK283. 16918 ong Dh Cu Sot An Khanh Wd ‘Thu Duc Ci Ho Ch ai iy Vitam ‘el (028 6266 29 - Fv: (020) 6265130 “2 wartecheastoreomyn- 1 nomtecnasarcnvt TECHMASTER x CALIBRATION REPORT Report Number: TSG-0-248715 ‘Manufacturer: EXTECH Model: RHT20 Asset No. / Serial No.2 AU24 / 161206316 4. Temperature Measurement Accuracy Test RengeFuncton [standavates] .A%, | '8, | comecton | esun | (2anded [Tolerance se} aoe | aes [ah ams sf 12%} 10 [40-09 [pass [-—oz8 [09] 22 Zc A raw} rays | 03 [pass one] 88 | a8 aC A a oc ude 248 °C 246 246 02 PASS. 0.24 23.8 25.8 208% | 207 | —o07 | 01 [pass | zt [208 | 208 a00% | “397 | —s07 | 02 —[pass_| 24 [500 | “a0 soa |“ —[ sos [0g pass | —oz8 [ea | “ap cose | sos | s99 | oa [pass] 021 [saa [en eave] ers [esos [pass] 028 [ese [as ote “The reported uncertainty of measurement was based on a standard uncertainty multiplied by a coverage factor k = 2.00, providing a level of confidence of approximately 95 %. -xplanation: “As Found: value before adjust + As Left: value after adjusted + Correction: The result of @ measurement in which the instrument gave @ reading is obtained by adding the correction to the reading. + Min/Max: range of value that Unit Under Test must be within in pass condition Inspected By Auditor: : Certified By Technician: Tuong Tuan Quoc Nguyen Van Tien Page 1 of 1 '540.1/Form-03-004 Rev.01

You might also like