Packaging Combination

Weigher System Operation


Guide

1. Program menu
(How to enter: Press "1", "E" or "OK" on the main interface)
Function: Select the program preset by the user.

2. Manual operation menu


(How to enter: Press "2", "E" or "OK" on the main interface)

There are 12 options under the manual operation menu:


1 COMBINATION Manual combination
2 ZERO RESET Zero reset
3 ZERO CLEAR Zero clear
4 MAIN FEEDER Main vibration machine single- step operation
5 LINEAR FEEDER linear vibration machine single-step operation
6 MOTOR ORIGNAL POINT Motor original point
7 FEED BUCKET FEED BUCKET single-step operation
8 WEIGH BUCKET WEIGH BUCKET single-step operation
9 CYCLE OPERATION Collecting hopper, weighing hopper,
feeding hopper, linear vibrating machine,
cycle operation
10 CONTINUOUS Collecting hopper, weighing hopper,
OPERATION feeding hopper, linear vibrating machine,
continuous operation
11 CONTINUOUS Collecting hopper, weighing hopper,
CYCLE OPERATION feeding hopper, linear vibrating machine,
continuous cycle operation
12 INHIBIT HEAD weighing bucket prohibited

3. Program selection, copy, edit, delete menus


(How to enter: press "3", "E" or "OK" on the main interface)

《1》 Program selection (How to enter: Press "1", "E" or "OK" under the menu
of program selection, editing, copying and deletion )
After inputting the program number, press "E" or "OK" (for example: "3", "E" or "OK"),
and the program "3" is currently being selected.
( 1)
《2》 Copy of program (How to enter: Press "2", "E" or "OK" under the menu
of program selection, editing, copying and deletion)
Copy the current program to the specified program number "X" (for example: "3", "E"
or "OK"), that is, copy the current program to the program number "3 ".

《3》 Program editing (How to enter: Press "3", "E" or "OK" under the
program selection, editing, copying and deleting menus)

There are the following main parameter adjustments in program


editing:

1. TARGET WEIGHT (g)


"Target Weight" (For setting the weight of the product to be packaged, in "grams")
2. H— LIMIT (g)
"The upper limit of the target weight" (Used to set the upper deviation of the
allowable target weight, the unit is "gram")

3. DUMP SPEED (x/min)


"Packing speed" ( Used to set the packing speed per minute, packs/minute)
4. MAIN FEEDER AMPLITUDE
"Amplitude of the main vibrating machine" (setting 0 is invalid for the main
vibrating machine) (the actual adjustable range is 1-60)

5. LINER FEEDER AMPLITUDE


"Amplitude of linear vibrator" (setting 0 is invalid for the main vibrator) (actually
adjustable range 1-60)

6. AUTO ZERO INTERVAL (min)


"Automatic zero compensation positive interval" ( usually set to 1-5, depending on
the amount of powder in the material, which means that the weighing bucket is
zero compensated every time during automatic operation . The unit is "minute")

7. INITIAL AUTO ZERO TIME (min)


"Initial zero compensation time" (Usually set to 0, unit "minute")
8. LINER FEEDER DRIVE TIME (ms)
"Linear vibration machine drive time" (Depending on the material, usually can be
selected from 100-900. The unit is "milliseconds")

9. LINER FEEDER DELAY ON TIME (ms)


"Delay drive time of linear vibrator" (Usually set to 0, which is used to delay the time
to drive the linear vibrator after the feed hopper is closed. The unit is "milliseconds")
( 2)
10. FEED BUCKET MOTOR PATTERN
"Feed Hopper Motor Mode" (There are 5 modes, usually "1" and "3" modes, "4" is
the half-open mode)

11. FEED BUCKET OPEN TIME (ms)


"Feed hopper opening time" (Usually set to 0, this time can only be used in the half-
open hopper motor mode, that is, "4" mode. The unit is "milliseconds" )

12. FEED BUCKET DELAY ON TIME (ms)


"Feed hopper delay drive time" (Usually set to 0, used to set the delay time to drive
the feed hopper after the weighing hopper is closed. The unit is "millisecond")

13. WEIGH BUCKET MOTOR PATTERN


"Weighing bucket motor mode" (There are 5 modes, usually "1" and "3" mode, "4" is
half- open mode)

14. WEIGHT BUCKET OPEN TIME (ms)


"Weighing bucket opening time" (Usually set to 0, this time can only be used in the
half- open bucket motor mode, that is, "4" mode. The unit is "milliseconds")

15. WEIGHT BUCKET DELAY ON TIME (ms)


"Weighing bucket delay driving time" (Usually set to 0, used to set the delay time to
drive the weighing bucket after the collection bucket is closed. Unit "millisecond")

16. SETTLE TIME (ms)


"Weighing stability time" (Usually set 750-900, indicating the time when the product
falls from the feed hopper to the weighing hopper becomes stable. The unit is
"milliseconds")

17. DUMP SIGNAL DELAY ON TIME (ms)


"Packing signal delay time" (Usually set to 0, which means that the weighing machine
will delay the output of the packaging signal to the packaging machine after the
weighing hopper is discharged during automatic operation. The unit is "milliseconds")

18. DUMP SIGNAL ON TIME (ms)


"Packaging signal turn-on time" (Usually set to 200ms or above, depending on
the minimum time that the PLC input terminal in the packaging machine can accept ,
means the packaging signal output to the packaging machine after the weighing
hopper is discharged during the automatic operation of the weighing machine .unit
"milliseconds")

19. OVER DISCHARGE ON (1) OFF (0)


"Excessive discharge switch" (Choose "1" means that the combined weight beyond the
upper and lower deviations can be discharged, when "0" is selected, the machine will
choose another close combined weight to discharge, until the suitable weight is not
( 3)
found, the machine will will stop working and immediately display an alarm message
on the display)

( 3)
20. MULTI DUMP COUNT
"Number of times of multiple packaging" (When the product packaging exceeds
500 grams, it needs to be set twice or more, the unit is "time")

21. NO LOAD DETECT (%)


"No material detection" (Usually set to 1%, if the weight reading of the weighing bucket
is less than this value, it is considered that the bucket is empty, and this percentage is
for the target weight)

22. BIAS (g)


"Deviation" (Usually set to 0, used for weight compensation. When the weight of
the product put down each time is always lower than a certain value, you can add this
value in the "Deviation" item, and the actual product weight will be Equivalent to set
weight + deviation, unit "gram")

23. NO SELECT DETECT


"No selection detection" (Usually set to 10, if the weighing hopper is not selected
within the set number of cycles, it will be forced to combine even if the weight is
exceeded, the unit is "times")

24. LOW LIMIT (g)


"Target weight lower limit" (Used to set the lower deviation of the allowable target weight)
25. TRANSFER TIME (ms)
"Transfer time" (Used to set the time for the product to fall from the weighing bucket
to the collection bucket, usually set 700-800, depending on the fluidity of the material)

《4》 Delete program


(How to enter: Press "4", "E" or "OK" under the menu of program selection,
editing, copying and deletion)
Program deletion (Select the program to be deleted and the number, press "E" or
"OK" to delete)

CAUTION: Consider carefully before delete the

program, to prevent program missing!

( 4)
4. Calibration menu
(How to enter: Press "4", "E" or "OK" on the main interface)
(1) INITIAL ZERO SETTING

"Initial zero setting" (select the bucket to be zeroed, and then press run. For
example:

to set the initial zero for No. 2 weighing bucket: press "2 ", " " or "OK", and then press "I")
(2) SPAN CALIBRATION

"Volume Calibration 300g" (Select the hopper to be calibrated, put a 300gweight


on

it and press run. For example, if I want to calibrate the scale of No. 2 weighing bucket
: press " 2 ", " E " or "OK", and then "Put weight" and then press " I " or "Run")

CAUTION: The "initial zero setting" operation


cannot be performed when the weight is put
down, and the "span calibration" operation
cannot be performed without the weight.

5. Calibration menu
(How to enter: Press "5", "E" or "OK" on the main interface)

(Same as above step 4)

( 5)
6. Setting options menu
(How to enter: Press "6", "E" or "OK" on the main interface, then press "1", "E" or "OK")

0 0 0 0 0 0 0 1 0 0
0 1 1 0 1 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
(1 is on, 0 is off)
1 COLLECTION BUCKET
Collection bucket switch
2 STAHHER DUMP Discharges sequentially
3 MULTLE DUMP Multiple packs
4 AVERAGE SYSTEM Average system
5 AFC DNON Automatic Tracking Control
6 ENGLISH Language selection
7 COUNTING Counting mode
8 MAIN FEEDER
Main vibration machine switch
9 CROSS HEAD FEEDER
Cross bucket feeder
10 CB OPEN EVERY DUMP Collects every time you open the package
11 CLEAN OUT DUMP SIGNAL Packing signal when clearing
12 DISCHARGE OVRE TW Discharges overweight material
13 CLLEAN OUT WHITHOUT READY Cleared when there is no ready signal
14 CHANGE OVER DECIMAL POINT
Decimal point printing
15 TEST SWTICH Test switch
16 W&M European weighing mode
17 EVERY DUMP SIGNAL OR MULITLI
Multiple unloading signal
18 CALIBRATION MINIMUM DISPLAY
Weight display (1 is 0.01, 0 is 0.1)
19 DATA WIGHSLAVE Combined weight follow the packaging machine
20 M. ERRORWB INHIBIT Weighing bucket is inhibited when the actuator is in error
21 DUMP SIGNAL RISE UP DITECT Prepare signal edge detection
22 RISE UP SIGNAL MEMORY Edge signal memory
23 INSERT THROW IN Unloading insertion signal
24 PRIORITY HEAD PRIORITY HEAD
25 CUSTOMER EYE Material detection electric eye
26 OPTION GATE Selection gate
27 ALARM SIGNAL Warning signal
28 DETECT SIGNAL Printer detector
29 RCU-700CONNECTION CHECK RCU-700 connection check

( 6)